Troubleshooting Your Glucose

DIABETES
RESOURCE SHEET

Hypoglycemia
Low glucose (hypoglycemia) occurs when there is too insulin available to help glucose enter the cells to be used
much insulin and not enough glucose in your blood. for energy. Without glucose, fat is used for energy result-
Some of the more common causes of hypoglycemia are ing in a waste product called ketones. If too many ketones
increased or unexpected activity and overestimation accumulate, (which can happen rapidly), the condition
of carbohydrate leading to a larger bolus than needed. becomes very serious and medical attention is required.

Hyperglycemia
Symptoms of Diabetic Ketoacidosis
High glucose (hyperglycemia) occurs when there is too
much glucose and not enough insulin in your blood. Early Symptoms Severe Symptoms
Stress, illness, medication, inactivity, and underestima- Thirst or dry mouth Nausea and vomiting
tion of carbohydrate leading to an inadequate bolus are
Frequent urination Abdominal pain
all common causes of high glucose.
High blood glucose Weakness or fatigue
Diabetic Ketoacidosis
Ketones in urine Labored breathing
Diabetic ketoacidosis occurs when there is not enough

Treatment Guidelines
If your glucose is above 250 mg/dL two times in a row When correcting for high glucose by syringe or pen, you
and/or is not responding to a correction bolus, test for can still track insulin on board (IOB) from your t:slim X2™
ketones, change entire infusion set and site, correct by insulin pump. Just follow the instructions included in the
injection, and follow guidelines below. Pump Tip on the back of this flyer to access this feature.

If Ketones Are NEGATIVE If Ketones Are POSITIVE

Visually inspect entire Use a correction Use a correction Change entire


infusion set and site. factor to calculate factor to calculate infusion set and site
Correct any problems and administer insulin and administer insulin using a new cartridge
if identified (see back). by syringe or pen. by syringe or pen. and new insulin.

Drink 8-12 ounces of Continue to monitor Drink 8-12 ounces of Continue to monitor
sugar-free fluids every every 1-2 hours until sugar-free fluids every every 1-2 hours until
30 minutes to prevent glucose returns 30 minutes to prevent glucose returns
dehydration. to normal. dehydration. to normal.

If glucose is not responding to the correction If glucose is not responding or if vomiting begins,
bolus, follow procedure for positive ketones. contact your healthcare provider, go to the ER, or call 911.
Troubleshooting
The chart below outlines possible causes that will need
PUMP TIP: To track IOB when dosing by injection,
to be investigated when your glucose is not responding
disconnect infusion set at site, deliver a bolus
to treatment. If the problem continues or you do not equal to the injection dose, and then reconnect.
find a solution, contact your healthcare provider (HCP).

Possible Issues What to Check If Yes . . .

Infusion set leaking at site Wetness at site Change infusion set at site and rotate site

Set not changed within 2-3 days Load history or site reminder Change infusion set at site and rotate site

Infection at site Redness, swelling at site Change infusion set at site and rotate site

Crimped, dislodged,
Infusion Set and Site

Infusion site Change infusion set at site and rotate site


or clogged cannula

Cannula placed in scar tissue Infusion site Change infusion set at site and rotate site

Detach tubing from site, fill tubing with insulin


Air bubbles in tubing Air bubbles or spaces in tubing
to push air out, and reattach tubing to site

Tubing not filled when Detach tubing from site, complete load
Load history
infusion set was last changed sequence, and reattach tubing to site

Detach tubing from site, tighten t:lock


t:lock™ infusion set connector
Tubing connection connector, fill tubing with insulin to push
is loose from tubing
air out, and reattach tubing at site

Insulin expired, denatured, or Insulin quality in vial Discard insulin and cartridge, fill new cartridge
exposed to extreme temperature or storage temperature with insulin, and change entire infusion set

Insulin in cartridge longer Discard insulin and cartridge, fill new cartridge
Load history
than recommended with insulin, and change entire infusion set
Insulin Pump

Programming error (eg, insulin Personal Profiles and


Reprogram as necessary
dose settings and time/date) time/date settings

Identify alarm and take action as outlined in


Alarm sounded Alarm history
your t:slim X2 insulin pump User Guide

Battery dead Battery icon Charge battery

Insulin pump is not Contact HCP to discuss need for


Discuss with your HCP
controlling glucose evaluation and adjustments to settings

Bolus error (missed, delivered


Bolus history Bolus as needed to correct
Behaviors

after meal or did not correct)

Stress, medication,
Life influences Discuss action plan with your HCP
illness, or inactivity

CONNECT WITH US ON:


(877) 801-6901
tandemdiabetes.com/training

Important Safety Information: Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. The t:slim X2 insulin pump with interoperable technology is an alternate controller enabled (ACE)
pump that is intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in people requiring insulin. The pump is able to reliably and securely communicate
with compatible, digitally connected devices, including automated insulin dosing software, to receive, execute, and confirm commands from these devices. The pump is indicated for use in individuals 6 years of age
and greater. The pump is intended for single patient, home use and requires a prescription. The pump is indicated for use with NovoLog or Humalog U-100 insulin. The t:slim X2 pump must be removed before MRI,
CT, or diathermy treatment. Visit tandemdiabetes.com/safetyinfo for additional important safety information.
© 2020 Tandem Diabetes Care, Inc. All rights reserved. Tandem Diabetes Care is a registered trademark and t:lock and t:slim X2 are trademarks of Tandem Diabetes Care, Inc. All third-party marks are the property
of their respective owners. ML-1005717_A
QUICK
Personal Profiles REFERENCE
on the t:slim X2 Insulin Pump UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the Tandem t:slim X2™ insulin pump, please refer to its User Guide.

3:24 PM B Options My Pump


1. 100% 14 Nov 235 u 2. 3.
STOP INSULIN Personal Profiles
BOLUS
Load Control-IQ

OPTIONS
Activity Alerts & Reminders

INSULIN ON BOARD (IOB) My Pump Pump Settings


Units 1.1 u Time Remaining 1:09 hrs

Tap OPTIONS. Tap My Pump. Tap Personal Profiles.

Personal Profiles Profile 1 Profile 1


4. 5. 6.
Timed Settings 9:00a - 1:00p
Weekday ON Edit
0.75 1:50 1:10 120
BASAL CORRECT CARB TARGET BG
Weekend OFF Activate

Bolus Settings
Exercise OFF Duplicate
6 hrs 12 u ON
DURATION MAX BOLUS CARBS
Delete

Tap the name of the Personal Tap Edit to edit or view Tap your current settings to see
Profile to view or edit. the settings. the full list of timed settings for the
entire day.

Timed Settings 12:00 AM


7. 8. 9. Confirm Settings?
12:00 AM Basal 0.75 u/hr
Basal 0.75 u/hr
0.60 1:50 1:15 140 Correction Factor 1u: 50 mg/dL
BASAL CORRECT CARB TARGET BG

3:00 AM Correction Factor 1u:50 mg/dL Carb Ratio 1u: 10g


X 0.70 1:50 1:15 140
Target BG 120 mg/dL
BASAL CORRECT CARB TARGET BG Carb Ratio 1u:10 g
7:30 AM
X 0.65 1:45 1:13 110 Target BG 120 mg/dL
BASAL CORRECT CARB TARGET BG

Tap the time segment the user Tap Basal, Correction Factor, Confirm settings. Recent changes
wishes to edit. Carb Ratio, or Target BG to make appear in orange.
changes, then tap .
If not all segments are visible, tap Tap to confirm.
the Down Arrow. When finished, tap .

(877) 801-6901
tandemdiabetes.com A free virtual pump demo

RX ONLY. All rights reserved. Tandem insulin pumps are intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in persons requiring insulin. The t:slim
X2 insulin pump is approved for individuals 6 years of age and older. For Important Safety Information, please visit tandemdiabetes.com/safetyinfo. © 2019 Tandem Diabetes Care, Inc. Tandem Diabetes Care is
a registered trademark and t:slim X2 and t:simulator are trademarks of Tandem Diabetes Care, Inc. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a
service mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC. ML-000314_E
QUICK
Load a Cartridge REFERENCE
Into the t:slim X2 Insulin Pump UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the Tandem t:slim X2™ insulin pump, please refer to its User Guide.

1. 2. 3. 4.
Options Load
Make sure the infusion set is
disconnected from your body. Remove the
STOP INSULIN Change Cartridge cartridge and
Are you ready to continue? install a filled
Load Fill Tubing cartridge. Press the
UNLOCK icon
when completed.
Activity Fill Cannula

My Pump Site Reminder On SCREEN IS LOCKED

From the Options menu, Tap Change Cartridge. A screen Disconnect the infusion set Remove the used cartridge.
tap Load. will appear to confirm that all from the user’s body and tap Install filled cartridge. Tap the
insulin deliveries will be stopped. to continue. unlock icon when completed.
Tap to continue. Tap to continue.

5. 6. 7. 8.
Fill Tubing Fill Tubing Load
Make sure the set is disconnected
from your body and securely
connect the tubing to your Fill Tubing START Fill Tubing STOP Change Cartridge
cartridge.
Amount Filled 0u Amount Filled 15.5 u Fill Tubing
On the next screen you will fill your
tubing with insulin.
Fill Cannula

OK Site Reminder ON

Verify that the infusion set is Hold the pump vertically to Tap STOP after three drops of From the Load screen, tap Fill
disconnected from the user’s ensure any air in the cartridge insulin are seen at the end of Cannula. Insert a new infusion
body. Connect the infusion set will be dispelled first. the infusion set tubing. set and connect filled tubing to
tubing to the tubing connector site, then tap .
Tap START. The pump will Verify that drops are seen and
on the cartridge. Tap . OK

beep or vibrate regularly while tap DONE. NOTE: When using a steel needle
the tubing is filled. infusion set, there is no cannula. Skip
to step 10.
9. 10. 11. 12.
Fill Cannula Site Reminder
Resume insulin now? RESUMING INSULIN

Edit Fill Amount 0.7 u Site Reminder This will resume all deliveries.

Fill Cannula START Scheduled Day Friday

Amount Filled 0u Scheduled Time 5:00 PM

Edit Reminder

Tap Edit Fill Amount. After the cannula fill is Load screen is displayed. The RESUMING INSULIN
complete, user may set a Site screen will appear.
Select amount needed for Tap . A reminder
Change Reminder.
cannula fill. Refer to the infusion to test BG in 1–2 hours
set Instructions for Use for Tap if correct. Tap Edit will display.
proper cannula fill amount. Reminder if settings need to
Tap .
Tap START. be changed.

(877) 801-6901
tandemdiabetes.com A free virtual pump demo

RX ONLY. All rights reserved. Tandem insulin pumps are intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in persons requiring insulin. The t:slim
X2 insulin pump is approved for individuals 6 years of age and older. For Important Safety Information, please visit tandemdiabetes.com/safetyinfo. © 2019 Tandem Diabetes Care, Inc. Tandem Diabetes Care is
a registered trademark and t:slim X2 and t:simulator are trademarks of Tandem Diabetes Care, Inc. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a
service mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC. ML-1002614_E
Instructions for Drawing Insulin From Vial Into Syringe
Use proper clean technique while performing the following:
1. Inspect the needle and syringe package for any signs of damage.
Discard any damaged product.
2. Wash hands thoroughly.
3. Wipe the rubber septum of the insulin vial with an alcohol swab.
4. Remove the needle and syringe from their packaging. Securely twist needle
onto syringe. Safely remove protective cap from needle by pulling outward.
5. Draw air into syringe up to the amount of insulin desired (see image A).
6. With insulin vial upright, insert needle into vial. Inject air from syringe into vial.
Maintain pressure on syringe plunger (see image B).
7. With needle still inserted into vial, turn vial and syringe upside down. Release
syringe plunger. Insulin will begin to flow from the vial into the syringe.
8. Slowly pull back the plunger to the desired amount of insulin (see image C).
9. While the filling needle is still in the vial and upside down, tap the syringe
so that any air bubbles rise to the top (see image D). Then slowly push
the plunger upwards, forcing any air bubbles back into the vial.
10. Check the syringe for air bubbles and do one of the following:
» If there are air bubbles present, repeat step 9.
» If no air bubbles are present, remove the filling needle from the vial.

Instructions for Filling the Cartridge


Depending on the pump model, an onscreen message will instruct the user either to load an empty cartridge or a filled cartridge onto the pump.

If instructed to load an unused (empty) If instructed to load a filled cartridge, Refer to the User Guide
that came with the
cartridge, perform the following after OR perform the following before loading
system for detailed
loading the cartridge onto the pump. the cartridge onto the pump. installation instructions.

1. Inspect the cartridge package for any signs of damage. Discard any
damaged product.
2. Open the package and remove the cartridge.
3. Hold the cartridge upright and gently insert the needle into the white insulin
fill port on the cartridge (see image E). The needle is not intended to go all
the way in, so do not force it.
4. Keeping the syringe vertically aligned with the cartridge, and the needle
inside the fill port, pull back on the plunger until it is fully retracted
(see image F). This will remove any residual air from the cartridge.
Bubbles will rise toward the plunger.
5. Make sure the needle is still in the fill port and release the plunger. Pressure
will pull the plunger to its neutral position but it will NOT push any air back
inside the cartridge (see image G).
6. Withdraw the needle from the fill port.
7. Turn the syringe upright and pull down on the plunger (see image H).
Flick the barrel to make sure that any air bubbles rise to the top.
8. Gently press on the plunger to remove air bubbles until insulin fills the needle
hub and you see a drop of insulin at the tip of the needle (see image I).
9. Re-insert the needle in the fill port and slowly fill the cartridge with insulin
(see image J). It is normal to feel some back pressure as the plunger
is depressed.
10. Maintain pressure on the plunger while the needle is removed from the
cartridge. Check the cartridge for leaks. If insulin leakage is detected,
discard the cartridge and repeat entire process with a new cartridge.
11. Always dispose of used needles, syringes, cartridges, and infusion sets
following community regulations.
QUICK
Deliver a Bolus REFERENCE
With the t:slim X2 Insulin Pump UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the Tandem t:slim X2™ insulin pump, please refer to its User Guide.

1. 0 2. Enter Carbs 3. 3.8


units grams units

CARBS GLUCOSE
1 2 3 CARBS GLUCOSE

0
grams
Add BG 4 5 6 38
grams
Add BG

7 8 9
View Calculation
+ 0 View Calculation

Tap 0 grams to enter the carbs for Enter desired value. Be sure Tap Add BG to enter your
the user’s bolus. “grams” is displayed above blood glucose.
keypad for food boluses.
NOTE: If this area reads “units,” the carb NOTE: If certain advanced features are being
feature is turned off in the active profile. Tap to continue. used, the current Dexcom G6 CGM reading
may auto-populate to the bolus calculator.
Please see the User Guide for more information.

4. Enter BG 5. 6. 3.58
Your BG is Below Target
mg/dL units
Reduce Bolus Correction?
1 2 3 CARBS GLUCOSE

Current IOB 0u
4 5 6
Current BG 110 mg/dL
38
grams
110
mg/dL
7 8 9
0 View Calculation

Enter desired value. Be sure If a BG is entered that is below the Tap to continue. Tap the
“mg/dL” is displayed above target, but above 70 mg/dL, the option calculated units value to manually
keypad when entering blood to reduce the bolus amount will appear. adjust recommended dose.
glucose (BG) values. To accept that reduction tap ;
otherwise, tap .

3:24 PM
7. Confirm Request? 8. Deliver 3.58 u Bolus? 9. 100% 14 Nov 235 u

Carbs 38 g Adjusted Correction 0u


BOLUS
Requesting 3.58 u Bolus ...
BG 110 mg/dL EXTENDED

Units To Deliver 3.58 u Adjusted Food 3.58 u OPTIONS

INSULIN ON BOARD (IOB)


Units 1.1 u Time Remaining 1:09 hrs

Verify the dose and tap Tap to deliver the food bolus To cancel the undelivered portion
to confirm. immediately. of the bolus, tap next to BOLUS
on the Home screen, then tap
NOTE: Calculations above are based The BOLUS INITIATED screen
to confirm canceled bolus.
on preset insulin-to-carb ratios and will appear to confirm delivery
correction factors, which may be set has started.
in Personal Profiles.

(877) 801-6901
tandemdiabetes.com A free virtual pump demo

RX ONLY. All rights reserved. Tandem insulin pumps are intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in persons requiring insulin. The t:slim
X2 insulin pump is approved for individuals 6 years of age and older. For Important Safety Information, please visit tandemdiabetes.com/safetyinfo. © 2019 Tandem Diabetes Care, Inc. Tandem Diabetes Care is a
registered trademark and t:slim X2 and t:simulator are trademarks of Tandem Diabetes Care, Inc. Dexcom and Dexcom G6 are registered trademarks of Dexcom, Inc. in the United States and/or other countries. Apple
and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC. ML-000312_F
QUICK
Deliver an Extended Bolus REFERENCE
With the t:slim X2 Insulin Pump UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the Tandem t:slim X2™ insulin pump, please refer to its User Guide.

1. 2. 3.
NOTE: If an above-target blood glucose
0 Enter Carbs 3.8
(BG) is entered, the correction bolus will
units grams units
not be extended.
CARBS GLUCOSE
1 2 3 CARBS GLUCOSE
NOTE: If certain advanced features are
0
grams
Add BG 4 5 6 38
grams
Add BG
being used, the current Dexcom G6 CGM
reading may auto-populate to the bolus
7 8 9 calculator. Please see the User Guide for
more information.
View Calculation
+ 0 View Calculation

Tap 0 grams to enter the carbs Enter desired value. Be sure Tap to continue, then tap
for the bolus. “grams” is displayed above to confirm.
keypad for food boluses.
NOTE: If this area reads “units,” the carb
feature is turned off in the active profile. Tap to continue.

4. 5. 6. 7.
Extend Food Bolus? 3.8 Confirm Request? Deliver 3.8 u Bolus?
units
Correction 0u Deliver Now 60% Now 2.28 u
DELIVER NOW DELIVER LATER

EXTENDED Deliver Later 40% Later 1.52 u

Food 3.8 u
60% 40% Duration 2 hrs Duration 2 hrs
DURATION

2 hrs View Units

Tap the toggler to the ON Tap to use default settings Tap to confirm. The delivery screen will confirm
position to extend the bolus. or tap DELIVER NOW and how much insulin will be
NOTE: If Control-IQ™ technology is
DURATION and set the desired delivered up front, how much
Tap to continue. turned on, extended boluses are limited
values, then Tap to will be delivered over time, and
to 2 hours. Please see the User Guide
continue. the delivery duration. Tap
for more information.
to start the bolus.

8. 9.
3:24 PM B
BOLUS INITIATED 100% 14 Nov 235 u

2.28 u Now + 1.52 u Later


BOLUS
Requesting 2.28 u Bolus ...

OPTIONS

INSULIN ON BOARD (IOB)


Units 1.1 u Time Remaining 1:09 hrs

The BOLUS INITIATED screen To cancel the undelivered


will appear to confirm delivery portion of the bolus, tap
has started. next to BOLUS on the Home
screen, then tap to
confirm canceled bolus.

(877) 801-6901
tandemdiabetes.com A free virtual pump demo

RX ONLY. All rights reserved. Tandem insulin pumps are intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in persons requiring insulin. The t:slim X2
insulin pump is approved for individuals 6 years of age and older. For Important Safety Information, please visit tandemdiabetes.com/safetyinfo. © 2019 Tandem Diabetes Care, Inc. Tandem Diabetes Care is a registered
trademark and Control-IQ, t:simulator, and t:slim are trademarks of Tandem Diabetes Care, Inc. Dexcom and Dexcom G6 are registered trademarks of Dexcom, Inc. in the United States and/or other countries. Apple
and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC. ML-000313_G
Stop and Resume Insulin Delivery QUICK
for the t:slim X2™ Insulin Pump REFERENCE

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of Tandem’s insulin pumps, please visit www.tandemdiabetes.com/support.

Stop Insulin Delivery

3:24 PM B Options
1. 100% November 14 235 u 2. BACK
3. This will stop all insulin deliveries.

STOP INSULIN Stop all deliveries now?


BOLUS
My Pump

OPTIONS
My CGM

INSULIN ON BOARD (IOB) Temp Rate BACK STOP


Units 1.1 u Time Remaining 1:09 hrs

Tap OPTIONS. Tap STOP INSULIN. Tap STOP.

Resume Insulin Delivery

3:24 PM ! Options
1. 100% November 14 235 u 2. BACK
3. This will resume all deliveries.

RESUME INSULIN Resume insulin now?


BOLUS
My Pump
OPTIONS
ALL DELIVERIES STOPPED
My CGM

INSULIN ON BOARD (IOB) Temp Rate CLOSE RESUME


Units 1.1 u Time Remaining 1:09 hrs

Tap OPTIONS. Tap RESUME INSULIN. Confirm by tapping RESUME.


NOTE: Any temp rates or boluses active
before you stopped delivery will not resume.
It will resume your active personal profile.

DOWNLOAD IT TODAY:
(877) 801-6901 Text DEMO to
www.tandemdiabetes.com A demo as simple as our pumps! TANDEM (826336)

RX ONLY. © 2019 Tandem Diabetes Care, Inc. All rights reserved. Tandem insulin pumps are intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in
persons requiring insulin. The t:slim X2 insulin pump is approved for individuals 6 years of age and older. For important safety information, please visit www.tandemdiabetes.com/safetyinfo. Tandem Diabetes Care
is a registered trademark and t:slim X2 and t:simulator are trademarks of Tandem Diabetes Care, Inc. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is
a service mark of Apple Inc. Google Play is a trademark of Google LLC. ML-000315_E
QUICK
Set a Temp Basal Rate REFERENCE
on the t:slim X2 Insulin Pump UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the Tandem t:slim X2™ insulin pump, please refer to its User Guide.

3:24 PM Activity Temp Rate


1. 100% 14 Nov 235 u 2. 3.
Exercise START Temp Rate 100%
BOLUS
Sleep START Duration 15 min
OPTIONS
Sleep Schedules View Units

INSULIN ON BOARD (IOB) Temp Rate


Units 1.1 u Time Remaining 1:09 hrs

Tap OPTIONS. From the Activity menu, Tap Temp Rate.


tap Temp Rate.
NOTE: For Control-IQ™ technology users,
Temp Rates are only available when
Control-IQ technology is turned off.

4. 80 5. Temp Rate
6. Temp Rate
%
Temp Rate 80% Temp Rate 80%
1 2 3
Duration 15 min Duration 6:30 hrs
4 5 6
View Units View Units
7 8 9
0
Using the onscreen keypad enter Tap Duration. Using the onscreen Verify settings and tap .
desired percentage. Tap . keypad enter desired length of time
for Temp Rate. Tap .
NOTE: Current rate is 100%. An increase is
greater than 100% and a decrease is less NOTE: To see the actual units to be
than 100%. delivered, tap View Units.

3:24 PM T Activity
7. TEMP RATE STARTED 8. 100% 14 Nov 235 u 9.
80% / 6:30 hrs
Exercise START

1 2 3 Sleep START

Sleep Schedules

INSULIN ON BOARD (IOB) Temp Rate 80%


Time Remaining 6:30 hrs
Units 1.1 u Time Remaining 1:09 hrs

The TEMP RATE STARTED screen The Lock screen will appear with NOTE: To stop a Temp Rate at any time,
will appear to confirm the Temp the orange T icon indicating a Temp tap OPTIONS, then Activity, then tap .
Rate has started. Rate is active. A confirmation screen will appear. Tap .
NOTE: If a Temp Rate of 0% is currently
active, the orange T icon will be replaced
with a red T icon.

(877) 801-6901
tandemdiabetes.com A free virtual pump demo

RX ONLY. All rights reserved. Tandem insulin pumps are intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in persons requiring insulin. The t:slim
X2 insulin pump is approved for individuals 6 years of age and older. For Important Safety Information, please visit tandemdiabetes.com/safetyinfo. © 2019 Tandem Diabetes Care, Inc. Tandem Diabetes Care is
a registered trademark and Control-IQ, t:slim X2, and t:simulator are trademarks of Tandem Diabetes Care, Inc. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries.
App Store is a service mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC. ML-000365_D
QUICK
Connecting the Dexcom G6 CGM Transmitter REFERENCE
to the t:slim X2 Insulin Pump UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the t:slim X2™ insulin pump, please refer to its user guide.

To connect Dexcom G6 CGM transmitter and Tandem pump: EVERY 3 MONTHS

1. 2. My CGM
3. Enter ID
Transmitter ID
START SENSOR
1 2 3
Calibrate CGM
4 5 6
CGM Alerts
7 8 9
Transmitter ID Press to Set Up
ABC 0
NOTE: Before starting, make sure the In the Options menu, tap the Enter transmitter ID and tap .
Dexcom transmitter is linked with the user’s Down Arrow > My CGM.
The user will be prompted to enter
t:slim X2 pump and not their Dexcom
Tap Press to Set Up located next the ID again to verify accuracy,
receiver. A single transmitter can’t be
to Transmitter ID. after which the transmitter will
connected to both at the same time.
be connected.
Locate the ID on the bottom of
the transmitter before attaching
it to a sensor. The transmitter ID
can also be found on the Dexcom
transmitter box.

To start a new sensor session: EVERY 10 DAYS

1. 2. Enter Code 3. You are ready to start your CGM


Sensor Code session. New sensor readings will
display on your home screen.
1 2 3
Start Sensor?
4 5 6
7 8 9
0
Locate the sensor code on the In the Options menu, tap the Down Tap to confirm the start of a
adhesive strip found on the Arrow, then: My CGM > START new CGM sensor session.
bottom of the applicator. SENSOR > CODE and enter
sensor code.
If user has already started a sensor
session on the Dexcom mobile app,
3:24 PM B tap My CGM > START SENSOR
4. 100% 14 Nov 235 u
> SKIP.
400
350
300
250 NOTE: The countdown If a sensor code is not entered prior to starting a sensor session,
200
symbol fills in over time the t:slim X2 insulin pump will prompt the user to calibrate using a
150 3
100 to show how much time blood glucose meter at regular intervals. By entering the sensor code,
HRS
50 is left before the system the user will not be prompted to calibrate the sensor.
INSULIN ON BOARD 1.1 u
is ready to display the If glucose alerts and readings do not match symptoms or
OPTIONS BOLUS current CGM reading. expectations, use a blood glucose meter to make diabetes
treatment decisions.
A symbol will appear on the Home screen to
indicate the two-hour startup process has
begun. During this time, user will not receive
sensor data or be able to use advanced features
such as Basal-IQ® or Control-IQ™ technology.
QUICK
Connecting the Dexcom G6 CGM Transmitter REFERENCE
to the t:slim X2 Insulin Pump UNITS OF MEASURE MG/DL

Dexcom G6 CGM and Tandem t:slim X2 Pump


Connection Tips

To maintain a steady connection between Dexcom Technical Support


the Dexcom G6 CGM and the Tandem » Insertion issues
» Site-related problems
t:slim X2 insulin pump, do the following:
(discomfort, bleeding, adhesive)
» Damaged CGM component
• Keep the phone with the Dexcom mobile app
dexcom.com/support
close to the user. The Dexcom transmitter
prioritizes communications with the Dexcom
Dexcom Care
app—to stay connected to both devices, keep » Get started with Dexcom G6 CGM
the phone within range. » Clinical account trainers and
Certified Diabetes Educators
• Make sure the pump and transmitter are on the
(CDEs) available
same side of the user’s body and that the pump
1-877-339-2664
screen is facing away from the body. patientcare@dexcom.com
• If you are having difficulty pairing a Dexcom
Tandem Technical Support
G6 transmitter with your t:slim X2 pump, try
» Signal issues
deleting and re-entering the transmitter ID.
» Error messages
» Other events communicated
For helpful videos, FAQs, and more information by the t:slim X2 insulin pump
visit tandemdiabetes.com/CGMsupport tandemdiabetes.com/support

(877) 801-6901
tandemdiabetes.com A free virtual pump demo

Important Safety Information: Caution: Federal (USA) law restricts the t:slim X2 insulin pump, the t:slim X2 pump with Basal-IQ technology, and Control-IQ technology to sale by or on the order of a physician.
The t:slim X2 pump, the t:slim X2 pump with Basal-IQ technology, and Control-IQ technology are intended for single patient use. The t:slim X2 pump, the t:slim X2 pump with Basal-IQ technology, and Con-
trol-IQ technology are indicated for use with NovoLog or Humalog U-100 insulin. t:slim X2 insulin pump: The t:slim X2 insulin pump with interoperable technology is an alternate controller enabled (ACE) pump
that is intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in people requiring insulin. The pump is able to reliably and securely communicate
with compatible, digitally connected devices, including automated insulin dosing software, to receive, execute, and confirm commands from these devices. The pump is indicated for use in individuals 6 years
of age and greater. t:slim X2 insulin pump with Basal-IQ technology: When used with a compatible integrated continuous glucose monitor (iCGM), the t:slim X2 insulin pump with Basal-IQ technology can be
used to suspend insulin delivery based on CGM sensor readings. The t:slim X2 pump with Basal-IQ technology is indicated for use in individuals 6 years of age and greater. Control-IQ technology: Control-IQ
technology is intended for use with a compatible integrated continuous glucose monitor (iCGM, sold separately) and ACE pump to automatically increase, decrease, and suspend delivery of basal insulin
based on iCGM readings and predicted glucose values. It can also deliver correction boluses when the glucose value is predicted to exceed a predefined threshold. Control-IQ technology is intended for the
management of Type 1 diabetes mellitus in persons 14 years of age and greater.

WARNING: Control-IQ technology should not be used by anyone under the age of six years old. It should also not be used in patients who require less than 10 units of insulin per day or who weigh less
than 55 pounds.

Control-IQ technology and the t:slim X2 pump with Basal-IQ technology are not indicated for use in pregnant women, people on dialysis, or critically ill patients. Users of the t:slim X2 pump, the t:slim X2 pump
with Basal-IQ technology, and Control-IQ technology must: be able and willing to use the insulin pump, CGM, and all other system components in accordance with their respective instructions for use; test blood
glucose levels as recommended by their healthcare provider; demonstrate adequate carb-counting skills; maintain sufficient diabetes self-care skills; see healthcare provider(s) regularly; and have adequate
vision and/or hearing to recognize all functions of the pump, including alerts, alarms, and reminders. The t:slim X2 pump, transmitter, and sensor must be removed before MRI, CT, or diathermy treatment. For
additional important safety information, visit tandemdiabetes.com/safetyinfo.
© 2020 Tandem Diabetes Care, Inc. All rights reserved. Tandem Diabetes Care and Basal-IQ are registered trademarks and Control-IQ, t:simulator, and t:slim X2 are trademarks of Tandem Diabetes Care, Inc.
Dexcom and Dexcom G6 are registered trademarks of Dexcom, Inc. in the United States and/or other countries. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries.
App Store is a service mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC. All other third-party marks are the property of their respective owners. ML-1005075_A
QUICK
View Status (with CGM) REFERENCE
on the t:slim X2 Insulin Pump with Control-IQ Technology UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the t:slim X2™ insulin pump, please refer to its user guide.

1. 2. 3. 4.
3:24 PM B Current Status Current Status Current Status
100% 14 Nov 235 u
400
350 82 Correction 14 Nov
mg/dL
P Weekday
Factor 1u: 42 mg/dL Last Calibration 10:02 PM
300
250
Time Sensor 14 Nov
200 B Basal Rate 0.625 u/hr Carb Ratio 1u: 12 g Started 12:15 PM
150 3
100 HRS 3u Transmitter
50
Last Bolus
14 Nov - 2:55 PM
Target BG 100 mg/dL Battery OK
INSULIN ON BOARD 1.1 u | 1:09 hrs
Mobile
Control-IQ ON Insulin Duration 4 hours Connection OFF
OPTIONS BOLUS

Tap the insulin level icon in Your t:slim X2 insulin pump will Tap the Down Arrow to display Tap the Down Arrow to display
the upper right corner of the display the name of the user’s the current Correction Factor, the Last Calibration, Time
Home screen. active profile, the current basal Carb Ratio, Target BG, and Sensor Started, Transmitter
rate, the time and amount of Insulin Duration. Battery status, and Mobile
the last bolus, and whether or Connection status.
not they are using Control-IQ™
technology.
If the user has an active
Extended Bolus, this screen
will show how much insulin has
been delivered out of the total
amount requested.

Explanation of Icons

The following icons may appear in the areas to the left or right of
the time and date on the t:slim X2 insulin pump’s Home screen:

A system reminder, alert, error, Control-IQ technology is increasing


3:24 PM or alarm is active. basal insulin delivery.
100% 14 Nov 235 u
400
82 Control-IQ technology is decreasing
350 A bolus is being delivered.
300 mg/dL basal insulin delivery.
250
200 Basal insulin is programmed
150 3 All insulin deliveries are stopped.
100
and being delivered.
HRS
50
INSULIN ON BOARD 1.1 u | 1:09 hrs
A temporary basal rate is active. A basal rate of 0 u/hr is active.
OPTIONS BOLUS

Control-IQ technology is delivering A temporary basal rate of 0 u/hr


an automatic correction bolus. is active.

CGM sensor session is active, CGM sensor session is active,


and the transmitter is but the transmitter is not
communicating with the pump. communicating with the pump.

(877) 801-6901
tandemdiabetes.com A free virtual pump demo
QUICK
View Status (without CGM) REFERENCE
on the t:slim X2 Insulin Pump with Control-IQ Technology UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the t:slim X2™ insulin pump, please refer to its user guide.

1. 2. 3. 4.
3:24 PM Current Status Current Status Current Status
100% 14 Nov 235 u

Correction
P Weekday
Factor 1u: 42 mg/dL Last Calibration NA
BOLUS
Time Sensor
B Basal Rate 0.625 u/hr Carb Ratio 1u: 12 g Started NA
OPTIONS 3u Transmitter
Last Bolus
14 Nov - 2:55 PM
Target BG 100 mg/dL Battery NA

INSULIN ON BOARD (IOB) Mobile


Control-IQ OFF Insulin Duration 4 hours Connection OFF
Units 1.1 u Time Remaining 1:09 hrs

Tap the insulin level icon in Your t:slim X2 insulin pump will Tap the Down Arrow to display Tap the Down Arrow to display
the upper right corner of the display the name of the user’s the current Correction Factor, the Last Calibration, Time
Home screen. active profile, the current basal Carb Ratio, Target BG, and Sensor Started, Transmitter
rate, the time and amount of Insulin Duration. Battery status, and Mobile
the last bolus, and whether or Connection status.
not they are using Control-IQ™
technology.
If the user has an active
Extended Bolus, this screen
will show how much insulin has
been delivered out of the total
amount requested.

Even with advanced systems such as the t:slim X2 insulin pump with Control-IQ technology, patients are still responsible for actively
managing their diabetes. Control-IQ technology does not prevent all high and low blood glucose events. The system is designed
to help reduce glucose variability, but it requires that patients accurately input information, such as meals and periods of sleep or
exercise. Control-IQ technology will not function as intended unless all system components, including CGM, infusion sets and pump
Responsible Use cartridges, are used as instructed. Importantly, the system cannot adjust insulin dosing if the pump is not receiving CGM readings.
of Control-IQ Since there are situations and emergencies that the system may not be capable of identifying or addressing, patients should always
Technology pay attention to their symptoms and treat accordingly.

(877) 801-6901
tandemdiabetes.com A free virtual pump demo

Important Safety Information: Caution: Federal (USA) law restricts the t:slim X2 insulin pump and Control-IQ technology to sale by or on the order of a physician. The t:slim X2 pump and Control-IQ technology
are intended for single patient use. The t:slim X2 pump and Control-IQ technology are indicated for use with NovoLog or Humalog U-100 insulin. t:slim X2 insulin pump: The t:slim X2 insulin pump with interop-
erable technology is an alternate controller enabled (ACE) pump that is intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in people requiring
insulin. The pump is able to reliably and securely communicate with compatible, digitally connected devices, including automated insulin dosing software, to receive, execute, and confirm commands from
these devices. The t:slim X2 pump is indicated for use in individuals 6 years of age and greater. Control-IQ technology: Control-IQ technology is intended for use with a compatible integrated continuous glucose
monitor (iCGM, sold separately) and ACE pump to automatically increase, decrease, and suspend delivery of basal insulin based on iCGM readings and predicted glucose values. It can also deliver correction
boluses when the glucose value is predicted to exceed a predefined threshold. Control-IQ technology is intended for the management of Type 1 diabetes mellitus in persons 14 years of age and greater.

WARNING: Control-IQ technology should not be used by anyone under the age of six years old. It should also not be used in patients who require less than 10 units of insulin per day or who weigh less
than 55 pounds.

Control-IQ technology is not indicated for use in pregnant women, people on dialysis, or critically ill patients. Users of the t:slim X2 pump and Control-IQ technology must: use the insulin pump, CGM, and all
other system components in accordance with their respective instructions for use; test blood glucose levels as recommended by their healthcare provider; demonstrate adequate carb-counting skills; maintain
sufficient diabetes self-care skills; see healthcare provider(s) regularly; and have adequate vision and/or hearing to recognize all functions of the pump, including alerts, alarms, and reminders. The t:slim X2
pump, transmitter, and sensor must be removed before MRI, CT, or diathermy treatment. For additional important safety information, visit tandemdiabetes.com/safetyinfo.
© 2020 Tandem Diabetes Care, Inc. All rights reserved. Tandem Diabetes Care is a registered trademark and Control-IQ, t:simulator, and t:slim X2 are trademarks of Tandem Diabetes Care, Inc. Apple and
the Apple logo are trademarks of Apple Inc., registered in the United States and other countries. App Store is a service mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC.
All other third-party marks are the property of their respective owners. ML-1005536_A
QUICK
Control-IQ Technology REFERENCE
for the t:slim X2 Insulin Pump UNITS OF MEASURE MG/DL

How Does Control-IQ Technology Work?


Control-IQ™ technology is designed to help increase time in range (70–180 mg/dL)* using Dexcom G6
continuous glucose monitoring (CGM) values to predict glucose levels 30 minutes ahead and adjust insulin
delivery accordingly, including delivery of automatic correction boluses (up to one per hour).

Control-IQ Sleep Activity Exercise Activity

Delivers an automatic correction bolus if sensor


Delivers glucose is predicted to be above mg/dL
180 –– 180

Increases basal insulin delivery if sensor


Increases glucose is predicted to be above mg/dL
160 120 160

Maintains active Personal Profile settings when


Maintains sensor glucose is between - mg/dL
112.5 - 160 112.5 - 120 140 - 160

Decreases basal insulin delivery if sensor


Decreases glucose is predicted to be below mg/dL
112.5 112.5 140

Stops basal insulin delivery if sensor


Stops glucose is predicted to be below mg/dL
70 70 80

*As measured by CGM.

Control-IQ Technology Pump Icons

Symbol Meaning Symbol Meaning

Control-IQ technology is on but not actively Control-IQ technology is delivering the normal
increasing or decreasing basal insulin delivery. Personal Profile basal rate.
Control-IQ technology is increasing basal Control-IQ technology is increasing basal
insulin delivery. insulin delivery.
Control-IQ technology is decreasing basal Control-IQ technology is decreasing the basal
insulin delivery. insulin delivery.
Control-IQ technology has stopped basal Basal insulin delivery is stopped and a basal
insulin delivery. rate of 0 u/hr is active.

BOLUS Control-IQ technology is delivering an automatic Control-IQ technology is delivering an automatic


correction bolus (or an automatic bolus). correction bolus.
Control-IQ: 2.8 u

The Sleep Activity is enabled. The Exercise Activity is enabled.

Even with advanced systems such as the t:slim X2™ insulin pump with Control-IQ technology, patients are still responsible for actively
managing their diabetes. Control-IQ technology does not prevent all high and low blood glucose events. The system is designed
to help reduce glucose variability, but it requires that patients accurately input information, such as meals and periods of sleep or
exercise. Control-IQ technology will not function as intended unless all system components, including CGM, infusion sets and pump
Responsible Use cartridges, are used as instructed. Importantly, the system cannot adjust insulin dosing if the pump is not receiving CGM readings.
of Control-IQ Since there are situations and emergencies that the system may not be capable of identifying or addressing, patients should always
Technology pay attention to their symptoms and treat accordingly.
QUICK
Control-IQ Technology REFERENCE
for the t:slim X2 Insulin Pump UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the t:slim X2™ insulin pump, please refer to its user guide.

To turn Control-IQ technology On or Off:

1. 2. 3. 4.
Options My Pump Control-IQ Control-IQ

STOP INSULIN Personal Profiles Control-IQ Control-IQ

Load Control-IQ Weight Press to Set Up

Activity Alerts & Reminders Total Daily Insulin Press to Set Up

My Pump Pump Settings

From the Options menu, Tap Control-IQ. From this screen, Control-IQ Next, enter the user’s weight
tap My Pump. technology can be toggled in pounds and average daily
on or off. insulin use in units. Total Daily
Insulin should be an estimate
of total basal and bolus insulin
the user requires in a 24-hour
period. Control-IQ technology
5. cannot be enabled unless both
Control-IQ NOTE: Patient must enter their weight and total daily insulin
weight, Total Daily Insulin (TDI), are entered.
Control-IQ have an active Personal Profile with NOTE: Existing t:slim X2 users can find
CARBS turned on, and an active their average Total Daily Insulin under
Weight 180 lbs
CGM session, in order to turn Options > History > Pump History
Total Daily Insulin 29 u
Control-IQ technology on. > Delivery Summary >
14-day Average.

Tap to save the settings.


Control-IQ technology is
now on.

(877) 801-6901
tandemdiabetes.com A free virtual pump demo

Important Safety Information: Caution: Federal (USA) law restricts the t:slim X2 insulin pump and Control-IQ technology to sale by or on the order of a physician. The t:slim X2 pump and Control-IQ technology
are intended for single patient use. The t:slim X2 pump and Control-IQ technology are indicated for use with NovoLog or Humalog U-100 insulin. t:slim X2 insulin pump: The t:slim X2 insulin pump with interop-
erable technology is an alternate controller enabled (ACE) pump that is intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in people requiring
insulin. The pump is able to reliably and securely communicate with compatible, digitally connected devices, including automated insulin dosing software, to receive, execute, and confirm commands from
these devices. The t:slim X2 pump is indicated for use in individuals 6 years of age and greater. Control-IQ technology: Control-IQ technology is intended for use with a compatible integrated continuous glucose
monitor (iCGM, sold separately) and ACE pump to automatically increase, decrease, and suspend delivery of basal insulin based on iCGM readings and predicted glucose values. It can also deliver correction
boluses when the glucose value is predicted to exceed a predefined threshold. Control-IQ technology is intended for the management of Type 1 diabetes mellitus in persons 14 years of age and greater.

WARNING: Control-IQ technology should not be used by anyone under the age of six years old. It should also not be used in patients who require less than 10 units of insulin per day or who weigh less
than 55 pounds.

Control-IQ technology is not indicated for use in pregnant women, people on dialysis, or critically ill patients. Users of the t:slim X2 pump and Control-IQ technology must: use the insulin pump, CGM, and all
other system components in accordance with their respective instructions for use; test blood glucose levels as recommended by their healthcare provider; demonstrate adequate carb-counting skills; maintain
sufficient diabetes self-care skills; see healthcare provider(s) regularly; and have adequate vision and/or hearing to recognize all functions of the pump, including alerts, alarms, and reminders. The t:slim X2
pump, transmitter, and sensor must be removed before MRI, CT, or diathermy treatment. For additional important safety information, visit tandemdiabetes.com/safetyinfo.
© 2020 Tandem Diabetes Care, Inc. All rights reserved. Tandem Diabetes Care is a registered trademark and Control-IQ, t:simulator, and t:slim X2 are trademarks of Tandem Diabetes Care, Inc. Dexcom and
Dexcom G6 are registered trademarks of Dexcom, Inc. in the United States and/or other countries. Apple and the Apple logo are treademarks of Apple Inc., registered in the United States and other countries.
App Store is a service mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC. All other third-party marks are the property of their respective owners. ML-1004929_B
QUICK
Sleep and Exercise Activities REFERENCE
for the t:slim X2 Insulin Pump with Control-IQ Technology UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the t:slim X2™ insulin pump, please refer to its user guide.

Sleep and Exercise Activities


Control-IQ™ technology offers optional settings for Sleep and Exercise Activities
that will change the treatment values when enabled.

To enable Sleep:

1. 2. 3. 4.
Options Activity Activity

STOP INSULIN Exercise START Exercise START

Load Sleep START SLEEP STARTED Sleep STOP

Activity Sleep Schedules Sleep Schedules

My Pump Temp Rate Temp Rate

From the Options menu Tap START next to Sleep. Sleep is now enabled. Tap STOP to turn Sleep off.
tap Activity.
NOTE: Sleep and Exercise cannot be NOTE: To disable Sleep Activity, repeat
enabled at the same time. the previous steps and tap STOP.

Using Sleep Schedules is Recommended


Within the Sleep Activity, users can set up two sleep schedules, which will automatically turn Sleep on and off
at pre-programmed times. For example, one might be set up for weekdays and the other for weekends.

1. 2. 3. 4.
Options Activity Sleep Schedule 1 Sleep Schedule 1

STOP INSULIN Exercise START Sleep Schedule 1


Basal-IQ Sleep Schedule 1
Basal-IQ

Load Sleep START Selected Days MTW Selected Days MTW

Activity Sleep Schedules Start Time 11:00 PM Start Time 11:00 PM

My Pump Temp Rate End Time 7:00 AM End Time 7:00 AM

From the Options menu Tap Sleep Schedules. Then, Select any or all days of the Tap to save the settings.
tap Activity. select one of the two Sleep week. Set the time that the
Schedules to set it up. sleep function will start and
end on those days. These times
should reflect the time the user
generally goes to sleep and
NOTES: wakes up.
» No Automatic Correction Boluses will be delivered during Sleep.
» If not using pre-programmed Sleep Schedules, Sleep must be manually
turned on and off.
» If you have a Sleep Schedule set and go to bed earlier/later it will still turn
off at the programmed time.
» If Exercise is enabled at the time sleep is scheduled to start, Sleep will
not begin. Once Exercise is turned off, the user will need to manually start
Sleep or wait until the next scheduled sleep cycle.
QUICK
Sleep and Exercise Activities REFERENCE
for the t:slim X2 Insulin Pump with Control-IQ Technology UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the t:slim X2™ insulin pump, please refer to its user guide.

To enable Exercise:

1. 2. 3. 4.
Options Activity Activity

STOP INSULIN Exercise START Exercise STOP

Load Sleep START EXERCISE STARTED Sleep START

Activity Sleep Schedules Sleep Schedules

My Pump Temp Rate Temp Rate

From the Options menu Tap START next to Exercise. Exercise is now enabled. Tap STOP to turn Exercise off.
tap Activity.
NOTE: Exercise and Sleep cannot be NOTE: To disable Exercise Activity,
enabled at the same time. repeat the previous steps and tap STOP.
NOTE: If Exercise is active at the time
sleep is scheduled to start, Sleep will
not begin. Once Exercise is turned off,
the user will need to manually start
Sleep or wait until the next scheduled
sleep cycle.

Even with advanced systems such as the t:slim X2 insulin pump with Control-IQ technology, patients are still responsible for actively
managing their diabetes. Control-IQ technology does not prevent all high and low blood glucose events. The system is designed
to help reduce glucose variability, but it requires that patients accurately input information, such as meals and periods of sleep or
exercise. Control-IQ technology will not function as intended unless all system components, including CGM, infusion sets and pump
Responsible Use cartridges, are used as instructed. Importantly, the system cannot adjust insulin dosing if the pump is not receiving CGM readings.
of Control-IQ Since there are situations and emergencies that the system may not be capable of identifying or addressing, patients should always
Technology pay attention to their symptoms and treat accordingly.

(877) 801-6901
tandemdiabetes.com A free virtual pump demo

Important Safety Information: Caution: Federal (USA) law restricts the t:slim X2 insulin pump and Control-IQ technology to sale by or on the order of a physician. The t:slim X2 pump and Control-IQ technology
are intended for single patient use. The t:slim X2 pump and Control-IQ technology are indicated for use with NovoLog or Humalog U-100 insulin. t:slim X2 insulin pump: The t:slim X2 insulin pump with interop-
erable technology is an alternate controller enabled (ACE) pump that is intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in people requiring
insulin. The pump is able to reliably and securely communicate with compatible, digitally connected devices, including automated insulin dosing software, to receive, execute, and confirm commands from
these devices. The t:slim X2 pump is indicated for use in individuals 6 years of age and greater. Control-IQ technology: Control-IQ technology is intended for use with a compatible integrated continuous glucose
monitor (iCGM, sold separately) and ACE pump to automatically increase, decrease, and suspend delivery of basal insulin based on iCGM readings and predicted glucose values. It can also deliver correction
boluses when the glucose value is predicted to exceed a predefined threshold. Control-IQ technology is intended for the management of Type 1 diabetes mellitus in persons 14 years of age and greater.

WARNING: Control-IQ technology should not be used by anyone under the age of six years old. It should also not be used in patients who require less than 10 units of insulin per day or who weigh less
than 55 pounds.

Control-IQ technology is not indicated for use in pregnant women, people on dialysis, or critically ill patients. Users of the t:slim X2 pump and Control-IQ technology must: use the insulin pump, CGM, and all
other system components in accordance with their respective instructions for use; test blood glucose levels as recommended by their healthcare provider; demonstrate adequate carb-counting skills; maintain
sufficient diabetes self-care skills; see healthcare provider(s) regularly; and have adequate vision and/or hearing to recognize all functions of the pump, including alerts, alarms, and reminders. The t:slim X2
pump, transmitter, and sensor must be removed before MRI, CT, or diathermy treatment. For additional important safety information, visit tandemdiabetes.com/safetyinfo.
© 2019 Tandem Diabetes Care, Inc. All rights reserved. Tandem Diabetes Care is a registered trademark and Control-IQ, t:simulator, and t:slim X2 are trademarks of Tandem Diabetes Care, Inc. Apple and
the Apple logo are trademarks of Apple Inc., registered in the United States and other countries. App Store is a service mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC.
All other third-party marks are the property of their respective owners. ML-1005162_A
QUICK
Pairing the t:connect Mobile App REFERENCE
with the t:slim X2 Insulin Pump UNITS OF MEASURE MG/DL

The instructions below are provided as a reference tool for caregivers who are already familiar with the use of an insulin pump and with insulin therapy in general.
Not all screens are shown. For more detailed information on the operation of the t:slim X2™ insulin pump, please refer to its user guide.

Download the App

Pairing the t:slim X2 insulin pump with a phone via Bluetooth® technology will allow the
pump to properly communicate with the t:connect® mobile app. If the proper software
version is installed on the pump, the whole process should take less than five minutes.
To begin the pairing process, visit the Google Play store or the Apple App Store,
search for “Tandem Diabetes” and select “t:connect mobile” from the results. It is
recommended to upload pump data via USB prior to syncing your pump with the app.

Enable Bluetooth Connection

Device Settings Bluetooth Settings


1. 2. 3. Turning the Mobile Connection on
will allow the pump to connect to
Display Settings Mobile Connection Bluetooth enabled mobile devices.
The t:connect mobile app may or
may not be available in your area.
Bluetooth Settings

Turn Mobile Connection on?


Time and Date

Sound Volume

Unlock the pump, tap OPTIONS, Tap the toggle to turn on the Mobile Select to turn on the Mobile
tap , tap Device Settings, then Connection and enable Bluetooth. Connection. A brief confirmation
select Bluetooth Settings. screen will show that the ability to
connect to a mobile device is now
NOTE: If Bluetooth Settings is not an option,
turned on.
you may need to update your pump software.
Visit portal.tandemdiabetes.com to check for
available software updates.

Pair App With Pump

Bluetooth Settings
1. 2. 3.
Select your pump
Activate Bluetooth on your pump in the
Mobile Connection
Bluetooth Settings menu.
Pair Device
Find the serial number on your pump at:
Make sure Bluetooth is active on both Options > My Pump > Pump Info
your phone and your pump.
t:slim pump ***123
Activate Bluetooth on your pump in the
Bluetooth Settings menu.

Refresh Next
Begin On the pump, select Pair Device
and then press to continue.

Go to the t:connect mobile app, Make sure the pump is within close
NeedBegin
login, and select help? to start the proximity to the phone. Once a
pairing process. Select OK on the connection is established, select
confirmation screen. the radio button next
Need help?to the pump’s
serial number and tap Next.
NOTE: Make sure that the Bluetooth setting
on the device has already been turned on.
Pair App With Pump (continued)

4. Pairing Code 5. 6.
DEVICE PAIRED
Using the mobile app, input the
code below to connect your pump
or close this prompt to cancel. You may now use the t:connect
Input your pairing code
mobile app to view data from your
Pairing Code View the pairing code on your pump pump.
within the Bluetooth Settings menu, by
A1b2 - C3d4 - E5f6 - G7h8 pressing “Pair Device”.

OK Pairing code is Case Sensitive. CLOSE

A1b2 C3d4 E5f6 G7h8


A unique pairing code will be Once the code has been success-
automatically generated. fully entered, a confirmation screen
Pair with pump will appear on the pump. Tap
NOTE: DO NOT press OK located under the
CLOSE.
unique pairing code, as this will cancel the
pairing process.
Enter the code that is displayed on
the pump directly into the mobile
NOTE: The unique code is only valid for five
app and press Pair with pump.
minutes. If the code expires, the pairing
process must be restarted by selecting Pair NOTE: The code isNeed
casehelp?
sensitive and must
Device from the Bluetooth Settings screen. be entered exactly as it is displayed. Your
unique code is only valid for five minutes. If
the code expires, you will need to begin the
pairing process again.

Refreshed 1 min ago


7. 8. 95% 235 u

Pump paired successfully


102 mg/dL
Insulin 0n Board
0.27 u
400
Your pump is now linked to your
t:connect account.

t:slim pump ***123

Sync pump data


183 180

138

70
50

Press Sync pump data. The app The app now displays the pump
will then import recent data from data and is5.56
ready for viewing.
the insulin pump. 1.0 u/hr 1.0 u/hr
NOTE: Data uploads to1.64
t:connect 0.0
do not take
NOTE: It is recommended to upload current
Need help?
4 place
AM in real-time
6 AM and require an internet
8 AM 9:36or
AM

pump data via USB to the t:connect web wireless data connection.
Current Status
application prior to syncing your pump with
Basal Rate 1 u/hr
the app.
Last Bolus 1.64 u
Correction
Nov 14 – 7:20 AM

(877) 801-6901 Control-IQ Setting ON


tandemdiabetes.com Profile Weekend
8:30 AM – 3:00 PM

Carbohydrates ON
The information on the t:connect mobile app display may not be identical to the current status Correction
of your pump. Wireless uploads
Factor 1 u : 45from
mg/dL the t:connect mobile app to the cloud-based t:connect web application require a
compatible phone and an internet or wireless data connection. Uploads to the t:connect web application do not take place in real time and should not be relied upon by healthcare providers or caregivers for remote
patient monitoring. Standard carrier data rates may apply. Carb Ratio 1 u : 12 g
Important Safety Information: Caution: Federal (USA) law restricts this device to sale by or on the orderBG
Target of a physician. The t:slim
100X2 insulin pump with interoperable technology is an alternate controller enabled (ACE)
mg/dL
pump that is intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in people requiring insulin. The pump is able to reliably and securely communicate
Insulin Duration
with compatible, digitally connected devices, including automated insulin dosing software, to receive, execute, and confirm commands 4:00 hrsfrom these devices. The pump is indicated for use in individuals 6 years of age
and greater. The pump is intended for single patient, home use and requires a prescription. TheLastpump is indicated for use with 12:04
Calibration NovoLog PM or Humalog U-100 insulin. The t:slim X2 pump must be removed before MRI,
CT, or diathermy treatment. Visit tandemdiabetes.com/safetyinfo for additional important safetyThursday,
information.
Nov 10
t:connect mobile app: The t:connect mobile app is intended to be a secondary display for compatible
Time SensorTandem Diabetes Care®10:19
Started insulinAMpumps and is capable of wirelessly uploading pump data it receives into the
t:connect web application. The t:connect mobile app is not intended to control an insulin pump and is not intended
Wednesday, Nov 12 to be a replacement for the information displayed on your insulin pump. Dosing decisions should not
be made based on this device. The user should follow instructions on the continuous glucose monitoring system. This device is not intended to replace self-monitoring practices as advised by a physician.
Transmitter Battery OK
© 2020 Tandem Diabetes Care, Inc. All rights reserved. Tandem Diabetes Care, t:connect, and t:slim X2 are either registered trademarks or trademarks of Tandem Diabetes Care, Inc. in the United States and/or other
countries. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play and the Google Play logo are trademarks of Google
LLC. The Bluetooth® wordmark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Tandem Diabetes Care, Inc. is under license. All other third-party marks are the property
of their respective owners. ML-1006074_B Dashboard Notifications Settings
Carbohydrate Counting
DIABETES
RESOURCE SHEET

What is a carbohydrate?
Calories from food derive from three nutrients: protein, starches are broken down into glucose, and glucose
fat, and carbohydrate. Each nutrient affects glucose levels start to rise. Insulin helps the body absorb the
differently, but carbohydrate has the greatest impact. glucose and use it for energy. Below is a short list of
Within minutes of eating carbohydrate, sugars and common foods that contain carbohydrate:

Fruits and fruit juice


Grains (ex: bread, cereal, rice, pasta)
(ex: orange, apple, grapefruit)

Starchy vegetables Milk and other dairy products


(ex: potatoes, corn, peas, beans) (ex: skim milk, yogurt, ice cream)

Non-starchy vegetables contain Desserts and other snacks


a small amount of carbohydrate (ex: cupcake, cookies, popcorn)

What is carbohydrate counting?


Carbohydrate counting is a method of estimating the
TRAINING TIP: The amount of carbohydrate
amount of carbohydrates in food. When combined with
needed varies from person to person. Speak with
insulin pump therapy, carbohydrate counting offers your healthcare provider for recommendations.
more flexibility with food choices and meal timing by
matching insulin more precisely with carbohydrate.
• Use a liquid measuring cup for measuring liquids. The
Estimating Carbohydrates liquid should be at level with the measurement line.
It is easy to under- or overestimate the amount of
• Use a kitchen scale for food that will not easily fit into
carbohydrate you are eating. Countless resources are
measuring cups, like whole fruit or bread.
available to help you estimate carbohydrate in food.
Some options are listed below:

• Printed and online resources in the form of books,


cookbooks, handouts, restaurant guides, etc. 3.17
units
• Software applications for your mobile device
CARBS GLUCOSE

• Nutrition Facts Labels (see reverse side)


38
grams
110
mg/dL

Weighing and Measuring Foods


Weighing and measuring the food you eat can help keep View Calculation

your carbohydrate counting accurate. Using measuring


utensils helps “train the eye” to better estimate portions.

• Use a dry measuring cup for measuring solid foods.


The amount of carbohydrate entered into your pump will determine
The food should be level with the top of the cup. how much insulin will be calculated and delivered as a Food Bolus.
Carbohydrate Reference Guide
Each food item in the guide below represents a 15-gram 15 Grams of Carbohydrate
carbohydrate choice. These are not suggested portions,
Starches Portion
but an added resource for estimating carbohydrate.
Bagel (large) 1/4

15 Grams of Carbohydrate Bread (white or whole wheat) 1 slice

Fruit, Juice, Dairy Portion Corn, Peas, or Beans (cooked) 1/2 cup

Apple, Orange, Peach, or Pear (small) 1 Grits or Unsweetened Oatmeal (cooked) 1/2 cup

Banana (very small) 1 Hamburger or Hot Dog Bun 1/2

Berries (black, blue, or raspberry) 3/4 cup Mashed Potatoes (plain white or sweet) 1/2 cup

Canned Fruit (unsweetened) 1/2 cup Pancake or Waffle (4 inches) 1

Fruit Juice (orange, apple, grape, etc) 1/2 cup Potato (large, baked) 1/4

Melon (cubed) 1 cup Rice or Pasta (cooked) 1/3 cup

Milk (skim, low fat, or whole) 1 cup Tortilla (corn) 1

Strawberries (whole) 1 1/4 cup Tortilla (flour) 1/2

Yogurt (plain or artificially sweetened) 2/3 cup


Note: Please refer to our Guide to Successful Pumping for a more complete list.

Nutrition Facts Label


Regulated by the U.S. Food and
Nutrition Facts TOTAL CARBOHYDRATE

8 servings per container


Drug Administration, the Nutrition Serving size 2/3 cup (55g) Keep your focus on Total
Facts Label is the most reliable and Carbohydrate. This reflects

230
Amount per serving
all carbohydrate including
easy-to-use resource for estimating Calories sugars, starch, dietary fiber,
carbohydrate in foods. % Daily Value*
sugar alcohol, and others.
Total Fat 8g 10%
Saturated Fat 1g 5%
Trans Fat 0g
SERVING SIZE Cholesterol 0mg 0%
Sodium 160mg 7% In this example, two-thirds of a cup
The Serving Size is based on one Total Carbohydrate 37g 13%
Dietary Fiber 4g 14% contains 37 grams of carbohydrate.
serving. It is not a suggested
Total Sugars 12g Let’s consider different serving sizes:
serving, but a reference for all of Includes 10g Added Sugars 20%
the label information. The listed Protein 3g • 19 grams in one-third of a cup
Serving Size may be different
Vit. D 2mcg 10% • Calcium 260mg 20%
than the amount you are eating. Iron 8mg 45% • Potas. 235mg 6% • 14 grams in one-fourth of a cup

CONNECT WITH US ON:


(877) 801-6901
tandemdiabetes.com/training

Important Safety Information: Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. The t:slim X2 insulin pump with interoperable technology is an alternate controller enabled (ACE)
pump that is intended for the subcutaneous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in people requiring insulin. The pump is able to reliably and securely communicate
with compatible, digitally connected devices, including automated insulin dosing software, to receive, execute, and confirm commands from these devices. The pump is indicated for use in individuals 6 years of age
and greater. The pump is intended for single patient, home use and requires a prescription. The pump is indicated for use with NovoLog or Humalog U-100 insulin. The t:slim X2 pump must be removed before MRI,
CT, or diathermy treatment. Visit tandemdiabetes.com/safetyinfo for additional important safety information.
© 2020 Tandem Diabetes Care, Inc. All rights reserved. Tandem Diabetes Care is a registered trademark and t:slim X2 is a trademark of Tandem Diabetes Care, Inc. All third-party marks are the property of their
respective owners. ML-1005718_A
Flying with your Tandem Insulin Pump
If you plan to travel by air with your insulin pump, some advance planning may make your security screening go
smoother. Your device is safe for use during air travel and complies with FAA wireless transmission standards. It
is also designed to withstand common electromagnetic interference and can be safely carried through metal
detectors.

However, your Tandem insulin pump should NOT be put through machines that use X-rays, including airline
luggage X-ray machines and full-body scanners. We recommend disconnecting at the infusion site and asking the
security agent for an alternative screening method. If you prefer to stay connected, you can notify the agent
about your pump and request to go through a standard metal detector wearing your pump.

It may be helpful to provide a printout of the information below to the security agent with your pump during
screening. If you have any questions about traveling with your pump, please call Tandem Customer Support at
(877) 801-6901*. We are here for you 24 hours a day, 7 days a week.

*If you are outside of the U.S. and need to contact customer support, please call +1-858-255-6269.

Fold here

Dear TSA or airport representative


This is an insulin pump from Tandem Diabetes Care, a life-
sustaining medical device prescribed by a physician. It is designed to
withstand common electromagnetic interference and can be safely Metal Detectors
carried through metal detectors, but should not be exposed to any
form of X-rays. This includes airline luggage X-ray machines and X-rays, including full body
full-body scanners. scanners and luggage
screening machines
Please provide a screening method other than X-ray for this insulin
pump. If you have any questions about this device, please call Tandem
Customer Support at (877) 801-6901*. We are available 24 hours a day,
7 days a week.

Sincerely,

www.tandemdiabetes.com

*If you are outside of the U.S. and need to contact customer support, please call
+1-858-255-6269.

ML-1000524_A