Professional Documents
Culture Documents
1. 350 mm
MIN. WIDTH FOR A PERIMETER STRIP FOOTING / 2 STOREY, WOOD FRAME BUILDING __________
2. MIN. WIDTH FOR A PERIMETER STRIP FOOTING / 2 STOREY, WOOD FRAME & 1.5 STOREYS OF
BRICK VENEER MASONRY 9.15.3.5. 1.a. = 65mm+65mm+350 mm =
_______________________ 480mm
3. A FOOTING IS 645MM IN WIDTH SUPPORTING A 290MM THICK CMU FOUNDATION WALL. MIN
9.15.3.5. 1.c. = 150mm+150mm+645 mm =
FOOTING THICKNESS IS : _____________________ 945mm
4. A FOOTING IS 470MM IN WIDTH SUPPORTING A 290MM THICK CMU FOUNDATION WALL. MIN
FOOTING THICKNESS IS : 9.15.3.5. 1.c. = 150mm+150mm+470 mm =
_____________________ 770mm
5. MAX. BACKFILL HEIGHT FOR A 3.0M HIGH, 290 MM CMU FOUNDATION WALL - LATERALLY
3.0 m
UNSUPPORTED AT THE TOP : ___________________
150mm
6. MIN. HEIGHT OF FOUNDATION WALL ABOVE GRADE IS : ____________________
7. MIN. COLUMN FOOTING AREA WHERE THE COL. SUPPORTS 2 STOREYS : Table 9.15.3.4. =0.75 m²
_________________
8. MIN. COLUMN FOOTING AREA WHERE FOR A COL. IN A BUNGALOW : Table 9.15.3.4.= 0.40 m²
_________________
9. REFER TO # 7 ABOVE. MIN. THICKNESS FOR THIS COL. FOOTING SUPPORTING A 150 X 150 WOOD
POST IS : __________________ Table 9.15.3.8.(1)= 100mm
10. REFER TO #7 & #9 ABOVE. MIN. FOOTING DIMENSIONS WHERE THE WOOD POSTS ARE SPACED @
4.0M
Table 9.15.3.4. 1 storey = 200X200 (int. walls) depth 100 mm
250X250 (ext. walls) depth 100 mm
2 storeys= 350x350 (int. and ext. walls)
depth 100 mm
Min. 32MPa
1. MIN. STRENGHT OF CONC. FOR GARAGE SLAB IS : ___________________
7. BEFORE BACKFILL, LIST : 6 STEPS TO PREPARE A CONC. FOUNDATION WALL & 5 STEPS TO PREPARE A
CMU WALL. 5 steps for a CMU wall:
6 steps for a conc. foundation wall:
5.1. Removal of Topsoil and Organic matter
6.1. Removal of Topsoil and Organic matter
5.2. Excavation
6.2. Excavation
5.3. Protection from freezing
6.3. Compact of soil
5.4. Prevent damaging of adjacent structures 25
6.4. Preparation of concrete
5.5. Insulate foundation
6.5. Introduction of concrete
6.6. Consolidation