5 Modbus Protocol (Take 32.4m/s as an example) Range of parameters 0-255 Default value: 2 Response: 00 16 10 00 01 8 C D8 (7 bytes)
Parameter storage Immediate storage Equipment Address 1 byte 0x00
The default value of communication parameters is:
The baud rate is 9600 bps, one start bit, eight data bits, Function number 1 byte 0x16
no check and one stop bit. Start register address 2 bytes 0x1000
Modbus address, can be set to 0-255. Any address can be set
Modbus register Number of registers 2 bytes 0x0001
by using 0 address. After setting, the module needs to be
check 2 bytes 0x8CD8
restarted to make this address effective.
Range and
Parame Modbus
Name of Register descriptio Default
ter Function Examples
parameter address
type number
n of values
Warning
parameters 1. Examples: Read register 0x0000, which is the measured
Failure to connect in sequence may cause damage to the
value of wind speed.
equipment and the instruments connecting the
Request: 02 03 00 00 00 01 84 39 (8 bytes)
equipment.
When the input power exceeds the maximum access power
supply of the equipment, it will cause damage to the
equipment.
Be careful
Read the instructions before using them.
Correctly Connect Equipment Circuits
First confirm
* Check whether the equipment is the same as the
equipment you purchased.
* Check whether the appearance of the equipment is
damaged or not
* Check whether the equipment accessories are complete