Table of Contents
Welcome
to the World of Process Instrumentation Introduction Process Instrumentation 2
No range of products will ever be large enough to provide Analysis Conductivity analysis 43
the optimal solution for every application. Often there are
requirements that change or move towards a better concept
that cannot be satisfied by existing products. This is why our
development engineers are able to work closely with custom-
ers to design and offer the very best customised solution. This Force and strain Force sensor 44
flexibility includes special mechanical housings or adaptations Strain sensor
to existing sensor designs. This ability to offer our customers
an innovative solution offers them a significant competitive
advantage.
Accessories Accessories 46
Mounting aids
Programmer
Introduction
Baumer products keep processes running
Many applications are subject to strict constraints. Tight regulation and approvals by
external agencies, such as materials and designs for food processing, hazardous area
approvals for flammable risks or safety critical testing for aviation and rail transport,
must be certified and met.
Baumer understand our customers needs in these industries, and thanks to our extensive
experience and ongoing technological development, can provide high performance
and reliable instruments to the required standards.
Market segments
2 www.baumer.com www.baumer.com 3
Electronic pressure measurement Electronic pressure measurement
Pressure
Wide range of process and electrical connections
Model CTL (*), CTX PBSN PBCN PBMN PDRx (class B and C) PBCX PBMX TED6, YTED
Pressure range -1 ... 0 to 0 ... 200 bar -1 ... 0 to 0 ... 600 bar -1 ... 0 bar to 0 ... 40 bar -100 ... 100 mbar 40 ... 1600 bar -1 ... 0 bar to 0 ... 40 bar -100 ... 100 mbar -1 ... 0 to 0 ... 400 bar
to 0 ... 1600 bar to 0 ... 1600 bar
Overpressure Max. 360 bar Max. 800 bar Max. 105 bar Max. 3200 bar Max. 3200 bar Max. 105 bar Max. 3200 bar Max. 600 bar
Accuracy ±1.0% F.S. ±0.7% F.S., ±0.5% F.S. ±0.5% F.S., ±0.25% F.S., ±0.5% F.S, ±0.25% F.S., ±0.3% F.S, ±0.5% F.S ±0.5% F.S, ±0.25% F.S., ±0.5% F.S, ±0.25% F.S., ±0.5% F.S.
(Linearity, repeatability, hysteresis) ±0.1% F.S. ±0.1% F.S. ±0.1% F.S. ±0.1% F.S.
Output signal 4 ... 20 mA, 0 ... 10 V, 1 ... 4 ... 20 mA, 0 ... 5 V, 0 ... 4 ... 20 mA, 0 ... 5 V, 0 ... 4 ... 20 mA, 0 ... 5 V, 0 ... 4 ... 20 mA, 0 ... 5 V, 0 ... 4 ... 20 mA, 0 ... 5 V, 0 ... 4 ... 20 mA, 0 ... 5 V, 0 ... 4 ... 20 mA, 2xPNP
5 V, 0.5 ... 4.5 V 10 V, 1 ... 5 V, 0.5 ... 4.5 V 10 V, 1 ... 5 V, 0.5 ... 4.5 V 10 V, 1 ... 5 V, 0.5 ... 4.5 V 10 V, 1 ... 5 V, 1 ... 10 V 10 V, 1 ... 5 V, 0.5 ... 4.5 V 10 V, 1 ... 5 V, 0.5 ... 4.5 V switching outputs
Process connection G¼, G½, ¼NPT, ½NPT G¼ EN 837, G½ EN 837, G¼ EN 837, G½ EN 837, G¼ EN 837, G½ EN 837, G¼ EN 837, G¼ DIN 3852, G¼ EN 837, G½ EN 837, G¼ EN 837, G½ EN 837, G¼, ¼NPT, G½, ½NPT,
¼NPT, ½NPT, G¼ DIN 3852, ¼NPT, ½NPT, G¼ DIN 3852, ¼NPT, ½NPT, G¼ DIN 3852, M12x1.5 EN 837, M12x1.5 ¼NPT, ½NPT, G¼ DIN 3852, ¼NPT, ½NPT, G¼ DIN 3852, M20x1.5, G¼ female
M20x150 M20x150, G¼ female M20x150, M14x150 cone DIN 3852 M20x150, G½ DIN 3852 M20x150, M14x150 cone
60°, G½ DIN 3852 60°, G½ DIN 3852
Electrical connection DIN 43650, pig tail cable DIN 43650, pig tail cable DIN 43650, pig tail cable DIN 43650, pig tail cable M12 plug, MIL DIN 43650, pig tail cable DIN 43650, pig tail cable M12-5 plug
outlet, M12 plug, ... outlet, M12 plug, ... outlet, M12 plug, ... outlet, M12 plug, ... outlet, M12 plug, ... outlet, M12 plug, ...
Technology Ceramic thick film Ceramic thick film Capacitive ceramic Piezoresistive silicon < 40 bar Metallic thin film Capacitive ceramic Piezoresistive silicon < 40 bar Ceramic thick film
Metallic thin film ≥ 40 bar Metallic thin film ≥ 40 bar
Protection class IP 65 IP 65, IP 67 IP 65, IP 67 IP 65, IP 67 IP 65, IP 67 IP 65, IP 67 IP 65, IP 67 IP 67
Approval UL Ex ia IIC T5/T6, ATEX II 1G Ex ia IIC T5/T6, ATEX II 1G TEX II 1G Ex ia IIC T6 or
A
Ex nA IIC T4/T5, ATEX II 3G Ex nA IIC T4/T5, ATEX II 3G T5 (YTED)
Ex tD A20 IP67 T100 °C, Ex tD A20 IP67 T100 °C,
ATEX II 1D ATEX II 1D
Additional data - (*) brass construction - C onfigurable - C onfigurable - C onfigurable - Configurable with - Configurable - 300° swivelling version
with FlexProgrammer with FlexProgrammer with FlexProgrammer FlexProgrammer with FlexProgrammer (option)
4 www.baumer.com www.baumer.com 5
Electronic pressure measurement Electronic pressure measurement
Pressure
LCD or LED display available
Model E93x ED 701, hygienic with ED 701, hygienic FlexBar HRT, hygienic FlexBar HRT, homogeniser FlexBar 3431, hygienic TED6, hygienic
cooling neck
Pressure range -1 ... 0 to 0.25 ... 40 bar 100 mbar ... 40 bar 100 mbar ... 40 bar -1(0) ... 400 bar 0 ... 400 bar -1(0) ... 400 bar -1(0) ... 400 bar
(60 ... 600 bar for homogeniser)
Overpressure Max. 80 bar Max. 120 bar Max. 120 bar 400% of M.R., max. 600 bar Max. 600 bar Max. 600 bar Max. 600 bar
(max. 800 bar for homogeniser)
Accuracy ±1.0% F.S. ±0.2% F.S., ±0.4% F.S. ±0.1% F.S., ±0.2% F.S., ±0.2% F.S. ±0.2% F.S. ±0.2% F.S. ±0.5% F.S.
(Linearity, repeatability, hysteresis) ±0.4% F.S.
Output signal 0 ... 20 mA, 4 ... 20 mA, 4 ... 20 mA, 4 ... 20 mA, 4 ... 20 mA, HART® 4 ... 20 mA, HART® Profibus® PA 4 ... 20 mA + 2 PNP
0 ... 10 V, 1 ... 5 V 0 ... 10 V, 0 ... 5 V 0 ... 10 V, 0 ... 5 V protocol protocol communication switching output
Process connection Clamp, DIN, SMS, G½ or Tri-Clamp, Clamp DIN Tri-Clamp, Clamp DIN ISO 2852 clamp, 3A hygienic, Flush PN 400 A, B, C, D G½, ½-14 NPT flush Clamp, DIN, SMS, G½ or G1
G1 with conical threading, 11864-3 and ISO 2852 11864-3 and ISO 2852 SMS 1145, DIN 11851, diaphragm with conical threading
homogeniser Varivent
Electrical connection DIN 43650, pig tail cable DIN 43650, cable output, DIN 43650, cable output, DIN 43650, pig tail cable DIN 43650, pig tail cable Cable, gland M16, M12 plug
outlet, M12 plug, HE302 plug M12 plug, field housing M12 plug, field housing outlet, M12 plug, ... outlet, M12 plug, ... M12 plug, DIN 13650 plug
Technology Ceramic thick film Piezo-resistive silicon Piezo-resistive silicon Piezo-resistive silicon Piezo-resistive silicon Piezo-resistive silicon Ceramic thick film
Protection class IP 65, IP 67 IP 65, IP 67 IP 65, IP 67 IP 65, IP 67 IP 65, IP 67 IP 66, IP 67 IP 67
Approval B V Marine, CSA, FM, L loyd's Register, ATEX II 2 G L loyd's Register, ATEX II 2 G E x ia, ATEX, 3A E x ia, ATEX II 1G, Ex ia IIC Intrinsically safe version
3A-Sanitary Standard and II 1D, Ex ia and II 1D, Ex ia T5/T6, 3A (Ex ia) conforms to ATEX
ATEX (Y930) Directive (YTED), 3A
Additional data - Intrinsically safe version - C onfigurable with - C onfigurable with - Configurable with - 300° swivelling version
(Ex ia) FlexProgrammer and FlexProgrammer and FlexProgrammer and HART® (option)
HART® configurator HART® configurator configurator
- F lexView LC-display - F lexView LC-display - FlexView LC-display optional.
optional optional Option: Hastelloy C276
- T urn down 25:1 - T urn down 25:1 - Turn down 25:1
6 www.baumer.com www.baumer.com 7
Electronic pressure measurement Electronic pressure measurement
Excellent repeatability
Pressure
Very good long term stability
Model E92x ED711 ED 701 FlexBar HRT FlexBar 3431 Model EDD 575 FKC
Pressure range 1.6 ... 600 bar 100 mbar ... 20 bar 100 mbar ... 40 bar -0.1 ... 0.4 to -1 ... 400 bar -1(0) ... 400 bar Pressure range 1 mbar ... 30 bar
Overpressure Max. 800 bar Max. 60 bar Max. 120 bar 400% of M.R., Max. 600 bar Static pressure 160 bar
max. 600 bar
Accuracy ±1.0% F.S. ±0.4% F.S. ±0.1% F.S., ±0.2% F.S., ±0.2% F.S. ±0.2% F.S. Accuracy (linearity, hysteresis ±0.1% F.S.
(Linearity, repeatability, hysteresis) ±0.4% F.S. and repeatability at 20 °C)
Output signal 0 ... 20 mA, 4 ... 20 mA, 4 ... 20 mA, 0 ... 10 V, 4 ... 20 mA, 0 ... 10 V, 4 ... 20 mA, HART® Profibus® PA Sensing element Stainless steel
0 ... 10 V, 1 ... 5 V 0 ... 5 V 1 ... 5 V protocol communication Silicium capacitive sensor
Process connection G½, G¾, G1 and ½NPT Male thread G½ flush G1 and G½ flush G½ or ½-14 NPT flush G½ or ½-14 NPT flush Supply voltage 10.5 ... 45 VDC
flush diaphragm diaphragm DIN 3852 diaphragm with cone, G½ diaphragm diaphragm
(CombiConnect) DIN 3852
Electrical connection DIN 43650, pig tail cable DIN 43650 Plug ; M12, 4 DIN 43650, cable output, Cable DIN 13650 plug Cable DIN 13650 plug Output signal 4 ... 20 mA, HART®
outlet, M12 plug, HE302 pole Industrial Plug M12 plug, field housing
plug
Technology Ceramic thick film Piezo-resistive silicon Piezo-resistive silicon Piezo-resistive silicon Piezo-resistive silicon Process connection 2 x 1/4 18 NPT female
Protection class IP 65, IP 67 IP 65 IP 65, IP 67 IP 65, IP 67 IP 65, IP 67 Protection class IP 67
Approval B V Marine, CSA, FM, L loyd‘s Register, ATEX II 2G E x ia, ATEX II 1G Ex ia IIC E x ia, ATEX II 1G Approval NEMA 4X, ATEX II 2G/D /
Lloyd‘s Register and II 1D, Ex ia T5/T6 Ex ia IIC T5/T6 Ex ia II CT T4 / T5
8 www.baumer.com www.baumer.com 9
Electronic pressure measurement Electronic pressure measurement
HeavyDuty transmitter
Pressure
Data acquisition
Leak detection
CANopen
Model FlexBar HRT, HART® FlexBar 3501, HART® FlexBar 3431, Profibus ® PA PDRJ, PDAJ, CANopen TEDM, ModbusTM BarFlex®
protocol protocol
Pressure range -1(0) ... 400 bar 100 mbar ... 40 bar -1(0) ... 400 bar 0 ... 1 to 0 ... 1000 bar -1(0) ... 400 bar -1(0) ... 400 bar
Overpressure Max. 600 bar Max. 105 bar Max. 600 bar Max. 2000 bar Max. 600 bar Max. 800 bar
Accuracy ±0.2% F.S. ±0.1% F.S. ±0.2% F.S. ±0.3% F.S. ±0.5% F.S. ±0.1% F.S., ±0.25% F.S.
(Linearity, repeatability, hysteresis)
Output signal 4 ... 20 mA, HART® 4 ... 20 mA, HART® Profibus® PA communication CANopen DS404 RS-485, ModbusTM RTU IrDA (infrared)
protocol protocol 2 isolated switching output
Process connection G½ and ½NPT flush G½, ½NPT, 3A hygienic G½ and ½NPT flush G¼ female G½, G¼, ½NPT, ¼NPT, M12x5, DIN2353,
diaphragm, hygienic connection, flush diaphragm, hygienic hygienic connections adaptor G½, ½NPT
connections diaphragm connections
Electrical connection Cable, gland M16 or M20, Cable, gland M20 Cable, gland M16, M12 M12 plug, connector MIL M12-8 plug IrDA port
M12 plug, Din 43650 plug C26482 or DIN 45322, PVC
cable
Technology Piezo-resistive silicon Capacitive ceramic Piezo-resistive silicon Metal thin film Ceramic thick film Ceramic thick film
Protection class IP 65, IP 67 IP 66, IP 67 IP 66, IP 67 IP 66 IP 67 IP 65
Approval E x ia, ATEX II 1G Ex ia IIC E x ia, ATEX II 1G Ex ia IIC E x ia, ATEX II 1G Ex ia IIC Ex ia IIC T6, ATEX II 1G
T5/T6 T5/T6 T5/T6
Additional data - C onfigurable with - C onfigurable with - C onfigurable with - Configurable with ModbusTM
FlexProgrammer and FlexProgrammer and FlexProgrammer software
HART® configurator HART® configurator - F lexView LC-display optional
- F lexView LC-display optional - F lexView LC-display optional -O ption : Hastelloy C276
-O ption : Hastelloy C276 -O ption : Hastelloy C276 - T urn down 25:1
- T urn down 25:1 - T urn down 25:1
10 www.baumer.com www.baumer.com 11
Mechanical pressure measurement Mechanical pressure measurement
Corrosive environment
Pressure
Many options: material of windows, filling liquid, overpressure
protection device, pointers
Nace compliant
Model MEX2, MEX3 MEX5, DRC100 MIX7 MEX8 MCX5, MCX7 DPC100, DPC150 DP100 hygienic
DN 50 and 63 mm 100 mm 150 mm 160 mm 100 and 150 mm 100 and 150 mm 100 mm
Pressure range -1 ... 0 to 0 ... 1000 bar -1 ... 0 to 0 ... 1600 bar -1 ... 0 to 0 ... 1600 bar -1 ... 0 to 0 ... 1600 bar -25 ... 0 to 0 ... 600 mbar -25 ... 0 mbar to 0 ... 25 bar 0 ... 6 to 0 ... 10 bar
-30“Hg to 0 ... 15.000 psi -30“Hg to 0 ... 20.000 psi -30“Hg to 0 ... 20.000 psi -30“Hg to 0 ... 20.000 psi
Accuracy class 1.6 1.0 1.0 1.0 1.6 and 2.5 1.6 1.6
Case material Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
Sensing element material Stainless steel, Stainless steel, Stainless steel, Stainless steel, Stainless steel Duratherm 600, Stainless steel
option: Monel option: Monel option: Monel option: Monel option PTFE coated
Process connection G¼, ¼NPT G½, ½NPT, M20x1.5 G½, ½NPT, M20x1.5 G½, ½NPT, M20x1.5 G½, ½NPT G½, flange Clamp connection ISO 2852
Varivent connection®
Paper connection with tubes
Type of mounting Bottom or back connection, Bottom or back connection, Bottom or back connection, Bottom or back connection, Bottom or back connection, Bottom connection Bottom connection
panel mounting flange, panel mounting flange, panel mounting flange, panel mounting flange, panel mounting flange,
clamp clamp clamp clamp clamp
Protection class IP 65 IP 65 IP 65 IP 65 IP 65 IP 54 IP 54
Approval E N 837-1, Lloyd‘s Register, E N 837-1, Lloyd‘s Register, E N 837-1, Lloyd‘s Register, E N 837-1, Lloyd‘s Register, E N 837-1, ATEX 94/9/CE DIN 16005
ATEX 94/9/CE (option) ATEX 94/9/CE (option) ATEX 94/9/CE (option) ATEX 94/9/CE (option) (option)
12 www.baumer.com www.baumer.com 13
Mechanical pressure measurement Mechanical pressure measurement
Pressure
Standard or "turret" design for oil and gas
application
Nace compliant
Model MEP5 MPG6, MPE6 MAN7 Model MCD7 MX7, MZ7 MFT
Process connection G½, ½NPT, M20x1.5 G½, ½NPT G½, ½NPT Type of mounting Bottom connection, panel Bottom or back connections, Wall mounting, panel
mounting (back fixing) panel mounting flange, pipe mounting and mounting on
Type of mounting Bottom connection, panel Bottom connection, panel Bottom or back connection, fitting 2" tube
mounting (3 back lugs mounting (back fixing) panel mounting flange
fixing) Protection class IP 66 IP 65 IP 65
14 www.baumer.com www.baumer.com 15
Mechanical pressure measurement Pressure applications
Pressure gauge with electrical contacts The broad product range contains first-class solutions for pressure measurement
in demanding environmental conditions as in the petro-chemistry or in salt-water
All Stainless steel
applications. In addition, we develop special solutions like for example for military
Local indication of the pressure and civil aeronautics or ship building. Many EPC-Contractors value Baumer as
a competent partner for process instruments for the construction of refineries,
Regulation or alarm actuation power plants or water treatment plants.
Intrinsically safe or explosion-proof version
Pressure
(conforms to ATEX)
Model MS5, MR5, DRCE 100, MCE MG5 M17, M27, M37
Protection class IP 65 IP 65 IP 65
Approval CE CE, ATEX Ex ia CE, ATEX Ex ia
16 www.baumer.com www.baumer.com 17
Pressure switch Pressure switch
Pressure control for industrial process manage- From vacuum to 600 bar
ment (level management, jack control, ...)
All industrial environments
Can be configured on site
Power generation safety equipments
Auto-zero function
Intrinsically safe or explosion-proof version
Pressure
Two set points, configured parameters of each (conforms to ATEX)
threshold
Nuclear versions
Pressure range -1 ... 0 to 0 ... 600 bar -1 ... 0 to 0 ... 400 bar -1 ... 0 to 0 ... 400 bar Pressure range 1 ... 100 bar -50 ... 0 mbar to -2.5 ... 2.5 mbar to
60 ... 600 bar 2.5 ... 30 bar
Overpressure Max. 800 bar Max. 600 bar Max. 600 bar
Overpressure / Static Max. 200 bar Max. 800 bar 0.15 ... 220 bar
Accuracy ±0.5% F.S. ±0.5% F.S. ±0.5% F.S.
(Linearity, repeatability, hysteresis) pressure
18 www.baumer.com www.baumer.com 19
Diaphragm seal Diaphragm seal
Diaphragm seal
Various material
Easy maintenance
Pressure
Cleaning-In-Place (CIP) and Sterilization-In-Place (SIP) without major disassembly
and assembly work
Model D040, D041 D05x series D1xx, D2xx, D3xx series D6xx series D4xx series
Type Single piece threaded Flush diaphragm threaded Standard threaded Flanged connection Flanged connection
connection connection connection
Pressure range D040 : 0 ... 1 to 0 ... 16 bar 0 ... 1 to 0 ... 600 bar D1xx: 0 ... 4 to 0 ... 160 bar -1 ... 0 to 0 ... 400 bar -1 ... 0 to 0 ... 400 bar
D041 : 0 ... 16 to 0 ... 250 bar D12x: 0 ... 160 to 0 ... 1000 bar
D2xx: 0 ... 1 to 0 ... 40 bar
D3xx: 0 ... 0.16 to 0 ... 25 bar
Wetted parts Stainless steel Stainless steel Stainless steel, Hastelloy, Stainless steel, Hastelloy, Stainless steel, Hastelloy,
Tantalum, Monel, Plastic Tantalum, Monel, Plastic Tantalum, Monel, Plastic
Working temperature -60 °C ... +200 °C -60 °C ... +200 °C -60 °C ... +200 °C -60 °C ... +200 °C -60 °C ... +400 °C
Process connection G¼, ¼NPT, G½, ½NPT, G¼, G½, ½NPT, G¾, ¾NPT, G¼, ¼NPT, G½, ½NPT, ISO / ANSI / ISO / ANSI /
¾NPT, ¼BSP-Tr, ½BSP-T G1, 1NPT, G1½, 1½NPT, G3/8, 3/8NPT, EN 1092-1 - Flanges EN 1092-1 - Flanges
G2, 2NPT
20 www.baumer.com www.baumer.com 21
Diaphragm seal Diaphragm seal
Hygienic connections for Food and Beverage or Flange connection for Chemical or Oil industries
Pharmaceutical, 3A-approval
Various types of ISO and ANSI flanges
Cleaning-In-Place (CIP) and Sterilization-In-Place
High temperature applications up to 400°C
(SIP) without major disassembly
Compatible with process pressure transmitters
Pressure
Model DANC - Clamp DADL - Hygienic DAVA - Varivent® 15xx, 16xx series Model D902 D8xx series
Diaphragm seals Diaphragm seals Diaphragm seals
Pressure range 0 ... 1 to 0 ... 40 bar 0 ... 1 to 0 ... 40 bar 0 ... 1 to 0 ... 40 bar 0 ... 1 to 0 ... 60 bar Pressure range - Relative and differential -1 ... 0 to 0 ... 400 bar
-1 ... 1.5 to -1 ... 39 bar -1 ... 1.5 to -1 ... 39 bar -1 ... 1.5 to -1 ... 39 bar min.10 mbar, absolute
pressure. min. 50 mbar
Process connection Clamp DN 25 ... 50 to NF, Hygienic with nut, smooth Varivent® DN 25, 40, 125 Clamp ISO/DIN, SMS 1145,
-Typical specifications:
ISO, DIN housing DN 25 ... 50 to DIN DIN 11851,
max. pressure: 100 bar
Sterile connection
Process connection 3 16L stainless steel flanges ISO / ANSI /
Media temperature -20...+225 °C max. -20 ... +150 °C max. -20 ... +150 °C max. DN 10 ... 100 / 1/2" ... 4" EN 1092-1 - Flanges
Operating temperature -20 ... +225 °C -20 ... +150 °C -20 ... +150 °C -20 °C ... +150 °C
Product specific application Product specific application Product specific application Wetted parts Stainless steel, Hastelloy,
complies with FDA complies with FDA complies with FDA Tantalum, Monel
recommendations recommendations recommendations
Media temperature Max. +400 °C
Special material Hastelloy C276 on request Hastelloy C276 on request Hastelloy C276 on request
Operating temperature -60 °C ... +400 °C
Approval 3A-Sanitary standard 3A-Sanitary standard 3A-Sanitary standard
Special material Hastelloy C276 on request
Protection class IP 65 (not air sensor) IP 65 IP 65
Additional data - Material: stainless steel - Flush diaphragm threaded
Additional data - Material: -M
aterial: -M
aterial: -W
etted parts: 1.4404 connection
stainless steel 1.4404 stainless steel 1.4404 stainless steel 1.4404 stainless steel
- Diaphragm: 316L stainless
- Diaphragm laser welded - Diaphragm laser welded - Diaphragm laser welded - One-piece tubular seal steel or Hastelloy C276
- Diaphragm material -D
iaphragm material -D
iaphragm material - Capillary tube: max. 12 m
stainless steel 1.4435 stainless steel 1.4435 stainless steel 1.4435
- Drain valve
- Surface roughness - S urface roughness - S urface roughness
- Vent valve
Ra ≤ 0,8 µm Ra ≤ 0,8 µm Ra ≤ 0,8 µm
- Steam tracing
- Option: e-polished - Option: e-polished - Option: e-polished
22 www.baumer.com www.baumer.com 23
Electronic temperature measurement Electronic temperature measurement
CombiTemp
User-configurable system
TE system
Temperature
Model CombiTemp CombiTemp CombiTemp TE1 TE2
Operating temperature Sensor -50 ... +400 °C Sensor -50 ... +400 °C Sensor -50 ... +400 °C Sensor -50 ... +250 °C Sensor -50 ... +250 °C
Transmitter -40 ... +85 °C Transmitter -40 ... +85 °C Transmitter -40 ... +85 °C Transmitter -40 ... +85 °C Transmitter -40 ... +85 °C
ambient ambient ambient ambient ambient
Response time 1.5 ... 6.1 sec., 1.5 ... 6.1 sec., 1.5 ... 6.1 sec., 3 sec., measured in liquids 3 sec., measured in liquids
(6 mm tube) τ0,5 measured in liquids measured in liquids measured in liquids
24 www.baumer.com www.baumer.com 25
Electronic temperature measurement Electronic temperature measurement
DIN-A or DIN-B – single or duplex element Offset function for precise calibration
Pt100 sensors for standard mounting in a High readability even in faint light
protection pipe for easy service
Battery life time over 3 years
Air sensor for mounting in a ventilation duct
TAR Temperature probe
Insertion sensor for meat cooking
All parts in stainless steel and welded
Hygienic conical sensor for welding into a pipe
Surface measurement – at the inner side
or tank wall
of the pipe
No "dead zones"
Temperature
Temperature
Model Cable sensors Insertion sensors Conical sensors Model BattTemp Model TAR
Temperature range -50 ... +205 °C -50 ... +205 °C -50 ... +205 °C Temperature range -200 ... +850 °C Temperature range -20 ... +200 °C
Accuracy DIN/EN/IEC 60751 DIN/EN/IEC 60751 DIN/EN/IEC 60751 Accuracy ±0.3 °C Accuracy Pt100 class B
1/1 DIN-B: 1/1 DIN-B: 1/1 DIN-B:
Operating temperature -10 ... +70 °C Ambient temperature -25 ... +80 °C
±(0.3 + 0.005 x t) °C ±(0.3 + 0.005 x t) °C ±(0.3 + 0.005 x t) °C
1/1 DIN-A: 1/1 DIN-A: 1/1 DIN-A: Temperature sensor input Pt100, 2-wire, Process connection Clamp ISO 2852
±(0.15 + 0.002 x t) °C ±(0.15 + 0.002 x t) °C ±(0.15 + 0.002 x t) °C DIN/EN/IEC 60751 Thread type DIN 11887
Sensor tube Acid-proof stainless steel FPM and Acid-proof Acid-proof stainless steel Protection class IP 65 Wetted parts W 1.4571 or W 1.4435
AISI 316 (W 1.4571) stainless steel AISI 304 AISI 316L (W 1.4404)
(W 1.4301) Approvals Ex ia IIC T4/T5, ATEX II 1G Protection class IP 65
Sheath dimensions 5.8 x 60 mm standard or air 105 x Ø 3 mm Tip Ø 3 mm Additional data - Ø 80 mm housing in Additional data - Hygienic pipe system
sensor with 8 holes Length 20 or 25 mm stainless steel AISI 304 - SIP and CIP
(W 1.4301)
Response time τ0,5 < 8 sec., measured in < 1.5 sec. in Water at 0.4 < 1 sec., measured in
- Front-configurable display
liquids 0.4 m/sec. m/sec., liquids 0.4 m/sec.
< 25 sec. in Air at 3 m/sec. - Battery powered
- Part of the CombiTemp
Media pressure < 25 bar (water flow 3 m/sec.) < 25 bar (water flow 3 m/sec.)
series
Protection class IP 65 (not air sensor) IP 65 IP 65 - Direct or remote mounting
Additional data - Sensors with 4-wire - Sensor tube in stainless -H
ygienic, without gasket - High cleanability and
silicone cable steel - C ompact mounting rugged design
- For pockets or tubes - Fast response time - F ast response time
- 4-wire sensors - Tolerates damp -W
ide temperature range
- High-flexible silicone grey - 4-wire sensors -A
cid-proof, stainless steel
cable - High-flexible silicone grey -H
igh-flexible silicone grey
cable cable
26 www.baumer.com www.baumer.com 27
Temperature switch Configurable temperature transmitter
Temperature
Model ETTN / YTTN RTA / RTN RT2N / RT2E / RT2Y Model FlexTemp 2301 FlexTemp 2311 FlexTemp 2321
Type Digital Mechanical Mechanical Output 4 ... 20 mA 4 ... 20 mA 4 ... 20 mA with HART®
Temperature range -200 ... +400 °C -46 ... +350 °C -46 ... +350 °C Pt100, 2-, 3-, 4-wire yes yes yes
Ambient temperature -25 ... +85 °C -30 ... +55 °C -30 ... +70 °C T/C, mVolt and Ohm input yes yes
Repeatability ±0.2% F.S. ±1% F.S. ±1% F.S. Namur NE21 yes
Set points 2 1 or 2 1
Linearisation table 0 ... 30 points 0 ... 30 points
Current rating 4 ... 20 mA, 2 threshold 5 mA ... 10 A 10 mA ... 10 A
outputs, PNP transistors, 250 VAC max. / 220 VDC 250 VAC max. / 220 VDC Damping 0 ... 30 sec. 0 ... 30 sec. 0 ... 15 sec.
400 mA at 24 VDC max. max. Accuracy (Pt100) < 0.25 °C < 0.1 °C < 0.1 °C
Electrical connection M12-5 pin connector Via internal terminal block Via internal terminal block Galvanic isolation 2 kVAC 2 kVAC
Sensor type Pt1000 probe, class A Rigid stem or Capillary tube Rigid stem or Capillary tube
Resolution 14 bit 16 bit 16 bit
Sensor material Stainless steel Stainless steel Stainless steel
Operating temperature -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C
Connection Sliding union G¼, G½, Stainless steel sliding Stainless steel sliding
Status indication 23/3.5 mA 23/3.5 mA 23/3.5 mA
¼NPT or ½NPT male connection male connection
(G½-½NPT) (G½-½NPT) Power supply 8 ... 35 VDC 6.5 ... 35 VDC 8 ... 35 VDC
Body / Housing material St. steel AISI 316L (1.4404) Aluminium Alloy Zamak plated black / Plastic
Protection class IP 67 IP 66 IP 66
Approval YTTN: Intrinsically safe RTNE: Explosion Proof RT2E: Explosion Proof
RTxY: Intrinsically safe RT2Y: Intrinsically safe
Additional data - ETTNM: Modbus commu- - E lectronuclear version
nication, outputs: static
relays, 400 mA at 60 VDC
or 40 VAC
28 www.baumer.com www.baumer.com 29
Configurable temperature transmitter Configurable temperature transmitter
Temperature
Temperature
Model FlexTop 2202 FlexTop 2203 FlexTop 2204 FlexTop 2211 FlexTop 2221 FlexTop 2231
Accuracy < 0.1% FS < 0.1% FS < 0.1% FS < 0.1 °C < 0.1 °C < 0.1 °C
Operating -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C -40 ... +85 °C
temperature
Power supply 8 ... 35 VDC 8 ... 35 VDC 8 ... 35 VDC 6.5 ... 35 VDC / 8 ... 35 VDC 8 ... 35 VDC / 8 ... 35 VDC 9 ... 32 VDC
Approvals Ex ia IIC T5/T6, ATEX II 1G Ex ia IIC T5/T6, ATEX II 1G Ex ia IIC T5/T6, ATEX II 1G Ex ia IIC T5/T6, ATEX II 1G Ex ia IIC T5/T6, ATEX II 1G Ex ia IIC T5/T6, ATEX II 1G
Additional data - NAMUR NE21 - NAMUR NE21 - NAMUR NE21 - NAMUR NE21 - NAMUR NE21 - NAMUR NE21
- C ompensation for "cold - Local, remote or fixed - Local, remote or fixed - Local, remote or fixed
junction" (CJC) internal, compensation for "cold compensation for "cold compensation for "cold
external or fixed junction" (CJC) junction" (CJC) junction" (CJC)
30 www.baumer.com www.baumer.com 31
Mechanical temperature measurement Mechanical temperature measurement
Bi-metal
Protection up to IP 68
High accuracy
Temperature
Model TB TBH TBI TBHI TBA TBL TBX / TBW
Housing Ø 40, 63, 80, 100, 160 mm Ø 80, 100 mm Ø 80, 100, 120, 130, Ø 100, 130 mm Ø 72 mm Ø 80, 100, 160 mm Ø 80, 100, 160 mm
160 mm
Temperature range -30 ... +500 °C -20 ... +250 °C -70 ... +600 °C -70 ... +600 °C 0 ... 120 °C / 0 ... 60 °C -30 ... +50 °C / -20 ... +60 °C -20 ... +250 °C
-20 ... +40 °C 0 ... 80 °C
Accuracy Class 1 (≤ 250 °C) Class 1 Class 1 (≤ 250 °C) Class 1 (≤ 250 °C) Class 1 Class 1 Class 1
Class 2 (> 250 °C) According to EN 13190 Class 2 (> 250 °C) Class 2 (> 250 °C) According to EN 13189 According to EN 13190 According to EN 13190
According to EN 13190 According to EN 13190 According to EN 13190
Case material Stainless steel AISI 304 Stainless steel AISI 304 Stainless steel AISI 304 Stainless steel AISI 304 Synthetic Stainless steel AISI 304 Stainless steel AISI 304
(1.4301) (1.4301) (1.4301) (1.4301) (1.4301) (1.4301)
32 www.baumer.com www.baumer.com 33
Mechanical temperature measurement Temperature applications
Gas filled thermometer Our electronic temperature instruments includes a wide range of standard and
hygienic process connections.
Flexible system with fix stem or capillary tube
Mechanical thermometers are still a good solution for the local indication near
Wide range of diameters to process. They work reliably even if there is no power on the system and allow
to check the state of the process.
All stainless steel design
Our higly reliable temperature switches are especially suited for critical applica-
Suitable for high temperature up to 800 °C tions in power plants and in the process industry.
Electrical contacts available
Temperature
Model TSS TSF
34 www.baumer.com www.baumer.com 35
Level switch Level switch
Rugged housing
Proximity switch
Up to 15 mm
Chemical resistant
Model Level Switch LFFS Level Switch LFFS Level Switch LBFS LSK x2x LSK x5x Model CFAH 30 FFAR
Sliding connection
Supply voltage 12 ... 36 VDC 12 ... 36 VDC 12 ... 30 VDC 18 ... 36 VDC 18 ... 36 VDC Supply voltage 10 ... 30 VDC 10 ... 30 VDC
Level
Ambient conditions PN ≤ 40 bar PN ≤ 16 bar PN ≤ 40 bar PN ≤ 16 bar PN ≤ 16 bar Measuring System Capacitive Photoelectric sensor
T = -40 ... +115 °C T = -40 ... +200 °C T = -40 ... +85 °C T = -20 ... +140 °C T = -20 ... +140 °C
Current consumption ≤ 35 mA ≤ 35 mA ≤ 35 mA ≤ 10 mA with amplifier Output current < 200 mA < 200 mA
Switching current ≤ 50 mA ≤ 50 mA ≤ 20 mA 50 mA max. including 5 A max. including amplifier Operating temperature -40 ... +200 °C 0 ... +65 °C
amplifier Type DNGA
Connection thread G½", 3A/DN38 Sliding connection G½“, G¾“, G1“ G½“ G1“ Mounting thread M30x1.5 G½“
Protection class IP 67 IP 67 IP 67 IP 67 IP 67 Protection class IP 67 IP 67
Approvals ATEX gas + dust, 3A ATEX gas + dust ATEX gas + dust 3A 3A Additional data - Housing: V2A / PTFE - Housing Ø 55 mm,
-N
ominal sensing distance: stainless steel
Additional data - Wetted parts in acid-proof, - Wetted parts in acid-proof, - S tainless steel housing - Stub or single rod: - Multi rod: 1.4404
stainless steel and PEEK stainless steel and PEEK L = 17 ... 2000 mm L = 200 ... 2000 mm up to 15 mm - Chemically resistant
- P rocess temperature -40
- Measures media with DK- - Process temperature -40 ... 105 °C - Signal detection: - Signal detection: - Adjustable by - Nominal pressure
values >1.5 ... 200 °C contact with media contact with media potentiometer (probe tip): max. 40 bar
-M easures media with DK-
- Not influenced by foam - Measures media with DK- values >1.5 - Output / Supply voltage: - Output / Supply voltage: - Connection types: - Connector M12x1
values >1.5 External / internal external switching module connector M12x1 - Housing with screw cap
- LED level monitor in the - L ED monitor in the cover
cover - Not influenced by foam switching module - Conductivity of media:
- C onfigurable by
- Configurable by - LED level monitor in the FlexProgrammer 9701 - Conductivity of media: ≥ 10µS/cm
FlexProgrammer 9701 cover ≥ 10µS/cm
- Configurable by
FlexProgrammer 9701
36 www.baumer.com www.baumer.com 37
Level measurement Level measurement
HeavyDuty
Fully programmable
Communication protocol
Submersible transmitter
Compact design
Model FlexBar HRT Flexbar 3501 FlexBar 3431, Profibus ® PA Model ED 752 ED 753
Submersible Submersible
Measuring range 0 ... 20 mbar to -1 ... 400 bar -1 ... 70 bar relative, 0 ... 20 mbar to -1 ... 400 bar Measuring range 0 ... 1 to 0 ... 400 mH2O 0 ... 6 mH2O
absolute Absolute ≥ 4 mH2O 0 ... 200 mH2O
Level
Absolute ≥ 6 mH2O
Span 30 points linearisation Auto Zero push button 30 points linearisation Span and zero adjustment 4 ... 20mA version:
Turn down 25:1 / 30 point with external zero setting
linearization
Output signal 4 ... 20 mA, HART® 4 ... 20 mA HART® Profibus PA Output signal 4 ... 20 mA, 0 ... 10 V, 4 ... 20 mA
0 ... 5 V
Process connection Standard: G½“, 3A hygienic, Standard: G½“ EN 837-1 Standard: G½“, 3A hygienic, Media temperature -10 ... +80 °C -10 ... +60 °C
flush diaphragm, Clamp, hygienic, Varivent® flush diaphragm,
Varivent® Varivent®
Protection class IP 65, IP 67 IP 67 IP 65, IP 67 Process connection M27x1.5 with or without G½
protection
(flush diaphragm)
38 www.baumer.com www.baumer.com 39
Level measurement Leak monitoring
Ultrasonic sensor
Hight accuracy
Level
Output signal 4 ... 20 mA Output signal 4 ... 20 / 20 ... 4 mA Supply voltage 10.8 ... 26.4 VDC
Ambient condition PN ≤ 16 bar Operating temperature 0 ... +60 °C Output current < 50 mA
T = -20 ... +140 °C Operating temperature -25 ... +50 °C
Conductivity of media ≥ 50µS/c Measuring system Utrasonic sensor Mounting thread 2 x knockouts Ø 4.5
Supply voltage 18 ... 36 VDC Supply voltage 15 ... 30 VDC Protection class
Process connection G1" Process connection M18 x 1.5 Additional data - Integrated electronics
Protection class IP 67 Protection class IP 67 - Detects liquid amounts of
approx. 1 ml
Approval 3A-Sanitary Standard Approval
- Chemically resistant,
Additional data - Single rod: 1.4404 Additional data -H
ousing: Ø 80 mm, protection by Teflon®
L = 200 ... 3000 mm stainless steel PFA sheath
- Current consumption - L C-Display:
200 mA 4 digits, 7 segment LCD
- 3 0-step linearisation
- E lectrical connection
PG / M12
40 www.baumer.com www.baumer.com 41
Level applications Conductivity analysis
Level
Accuracy ±1% of selected measuring range
Span and zero adjustment Given by adjusted pressure and temperature ranges
Supply voltage 18 ... 36 VDC, 180 mA max.
Output signal Conductivity: 4 ... 20 mA, Temperature: 4 ... 20 mA
Analysis
Operating temperature -20 ... +130 °C (short time up to +140 °C)
Process connection G 1“ hygienic design acc. 3A requirements
Protection class IP 67
Additional data - Housing: stainless steel 1.4301, with screw cap incl.
window
- Adjustment through menu using push-turn button
- Programme sequence: external selection of up to 4
pre adjusted measuring ranges possible
- Media pressure: 10 bar max.
- Wetted materials: stainless steel 1.4404, PEEK
- Process connection: G1" rotating gland allows easy
positioning of the instrument
- 3A approval
42 www.baumer.com www.baumer.com 43
Force sensor Strain sensor
Protection class IP 67
Product family DLRx L001 DLRx L002 DLRx L002 DLRx L003 Product family DSRT 22Dx Classification DSPN 27
Load transmission Compressive load Compressive load Tension / Compressive load Tension / Compressive load Measuring range +/-100 ... +/-750 με Measuring range 0 ... 500 με
Sensibility 1 mV/V 2 mV/V 2 mV/V 2 mV/V Output signal CANopen,+/-10V, 4 ... 20mA Sensibility 900 pC/με
Force range 0 ... 5 kN 0 ... 0.5 kN 0 ... 0.5 kN 0 ... 10 kN Accuracy <1% Linearity < +/-1 %
0 ... 10 kN 0 ... 1 kN 0 ... 1 kN 0 ... 20 kN
0 ... 2 kN 0 ... 2 kN 0 ... 30 kN Dimension 26 x 80 x 17 mm Dimension ø 40 x 18 mm
0 ... 5 kN 0 ... 5 kN 0 ... 50 kN
0 ... 10 kN 0 ... 10 kN 0 ... 100 kN Protection class IP 65 Protection class IP 65
Dimension ø 32 x 17 mm ø 55 x 30 mm ø 55 x 51 mm ø 155 x 46 mm Characteristics - Full bridge Characteristics - Ideal for mold protection
- Excellent signal to noise - Measures smallest strains
Output 0 ... 10 V, 4 ... 20 mA 0 ... 10 V, 4 ... 20 mA +/-10 V, 4 ... 20 mA +/-10 V, 4 ... 20 mA
ratio - For cyclic applications
Characteristics - Full bridge - F ull bridge - Full bridge - F ull bridge - For static and dynamic - Amplification with
- Amplification with -A
mplification with - Amplification with -A
mplification with applications DACU 820
DABx AD2T DABx AD2T DABx AD2T DABx AD2T
Force
44 www.baumer.com www.baumer.com 45
Accessories Accessories
Pressure accessories
Various materials
Easy maintenance
Temperature accessories
Sliding connections
Model AORP, AORPB ARA ASIP AKPL ARPX AMFD Model 8139 T8410, T8911, T669x,
T9093
Type Pressure Pressure Siphon Capillary Needle Manifold Type Temperature sensor pockets Thermowells
limitor dampener valve
Working temperature +150 °C maxi +250 °C maxi +400 °C maxi +400 °C +250 °C maxi +200 °C maxi
Process connection ½NPT female thread G½, ½NPT female thread G½, ½NPT male or female G½, ½NPT male or female G½, ½NPT male or female ½NPT female thread
thread thread thread
Accessories
46 www.baumer.com www.baumer.com 47
Mounting Aids Programmer
High quality stainless steel Dedicated configuring tool for Baumer products
(pressure, temperature and level)
Wide variety of process connections for critical
process applications Portable flexibility with battery supply
Also used in sterile environment Operated and recharged from a USB port
Model Adapters Welding Sleeves, Tanks Welding Sleeves, Pipes Model FlexProgrammer 9701
CAM, VAM, LAM, RAM, SAM PM020, PM021, PM023, PM022, PM025, PM031,
PM050, PM053, PM200 PM032, PM033, PM035, Supply voltage From USB-port or from rechargeable battery
PM052, PM200
Software FDT/DTM based
Compatible sensors FlexBar / ED701 / LSP /LSK / FlexBar / ED701 / LSP /LSK / FlexBar / ED701 / LSP /LSK / Ambient values 0 ... +50 °C, rel. humidity <90%
ISL / LFFS ISL / LFFS ISL / LFFS
Protection class IP 42
Sensor thread options 9 (15) ... 30 VDC M12 / G1/2“ / G1“ M12 / G½" / G1"
Additional data - Easy configuring with menu control function
Media pressure See device See device See device - Data transfer from PC to device via USB
Approval 3A Sanitary standard 3A Sanitary standard 3A Sanitary standard - Configuration of a device on the spot without a PC
Depending on the sensor Depending on the sensor Depending on the sensor - Robust plastic case with digital display and buttons
specification specification specification
- Rechargeable battery type NiMH 2,4 V, 450mAh
Additional data - Execution: - Material: -M
aterial: - Free FlexProgram updates from our web site
with Clamp DIN/ISO, Stainless steel 1.4404 Stainless steel 1.4404
Varivent®, hygienic, ... - Sealing material: No seal - Sealing material: no seal
- Material: - Cleaning: According to - C leaning:
stainless steel 1.4404 specifications CIP and SIP According to specifications
- Sealing material: - A mark indicates the final CIP and SIP
no seal or EPDM gasket gland or plug position -M
aterial certificate:
- Cleaning: According to - Material certificate: 3.1 B (option)
specifications CIP and SIP
Accessories
3.1 B (option)
- Material certificate:
3.1 B (option)
48 www.baumer.com www.baumer.com 49
Innovations Other product segments
50 www.baumer.com www.baumer.com 51
Worldwide presence
Baumer International
International Sales
Baumer Group
International Sales
At Baumer we like to be close to our customers; we listen to them and, under-
P.O. Box
standing their needs, provide the best solution. Worldwide customer service for Hummelstrasse 17
Baumer starts with on-the-spot personal discussions and qualified consultation. CH-8501 Frauenfeld
Our application engineers speak your language and strive from the start, through Phone +41 (0)52 728 1122
sales@baumer.com
an interactive problem analysis, to offer comprehensive and user-compatible
solutions.
The worldwide Baumer sales organizations guarantee short delivery times and
local product availability. Many of our customers are directly linked via our Europe
electronic order system with the Just In Time logistics process.
Austria France Poland Switzerland
A worldwide network coupled with the most modern communication techniques Baumer GmbH Baumer Bourdon-Haenni S.A.S. Baumer Sp.z.o.o. Baumer Electric AG
enable us to deliver information quickly and transparently to decision makers in Wiener Neustädter Strasse 13D/1/7 125, rue de la Marre, BP 70214 ul. Odrowaza 15 P.O. Box, Hummelstrasse 17
all Baumer locations. AT-2514 Traiskirchen FR-41103 Vendôme cedex PL-03-310 Warszawa CH-8501 Frauenfeld
Phone 0800/070020 Phone +33 (0)2 5473 7475 Phone +48 (0)22 832 15 50 Phone +41 (0)52 728 1313
Closeness to the customer for Baumer means being available for your needs any- sales.at@baumer.com sales.fr@baumerprocess.com sales.pl@baumer.com sales.ch@baumer.com
where and at any time.
Belgium Germany Spain/Portugal United Kingdom
Baumer SA/NV Baumer GmbH Baumer Bourdon-Haenni SAS Baumer Ltd.
Rue de Nieuwenhove, 45 Pfingstweide 28 c/ Dr. Carulla No. 26-28, 3, 2a 33/36 Shrivenham Hundred
BE-1180 Bruxelles DE-61169 Friedberg ES-8017 Barcelona GB-Watchfield, Swindon, SN6 8TZ
Phone +32 (0)2 344 18 14 Phone +49 (0)6031 6007-0 Phone +34 (0)93 254 7864 Phone +44 (0)1793 783 839
sales.be@baumer.com sales.de@baumer.com sales.es@baumer.com sales.uk@baumer.com
America
Asia