Professional Documents
Culture Documents
PROFESSIONAL MEASUREMENT
Measuring | Controlling | Regulating
MADE IN GERMANY
Product catalog
201
016
6
93128 Regenstauf | Hans-Sachs-Straße 26
+49 - 9402 - 9383 - 0 | www.greisinger.de
+49 - 9402 - 9383 - 33 | info@greisinger.de
01/2016
COMPANY
Handheld instrument
Greisinger was founded on 01/01/1980 in Regenstauf near Regensburg and has For instance, GHM Greisinger has an air-conditioned calibration room with an
been a prominent supplier of measurement technology for more than 35 years. area of over 60 m² in which factory and production calibrations of temperature,
Greisinger is a specialist in measurement and regulation technology for pressure, humidity, etc. are carried out.
laboratory and industrial applications with a focus on in-house developments. For many applications, particularly in the scope of ISO 9000 ff., documented
We work with the development and production of measuring and regulating measurements are required. Our reference standards are based on national
devices and the corresponding sensors systems. The company's total standards and are continuously monitored.
production area is about 2250 m². More than 50 employees develop and For fulfi lment of the quality standard in accordance with ISO 9000 ff. for the
produce high-quality products at affordable prices with the latest development, customer, most devices produced there are also supplied with a factory
production and testing equipment. calibration certifi cate or DAkkS certifi cate.
Display / Controller
The company's equipment has recently been expanded to include a fully
shielded measuring cabinet for the EMC testing that accompanies development
and for EMC fi nal testing.
Logger / EASYBus
company building
Transmitter
fi xture in the measuring device market. We have been on a continuously
upward trend for more than 35 years. The use of state of the art machinery and MADE IN GERMANY
devices with effi cient, high-performance production processes enables the high
'Made in Germany' product quality at competitive prices.
ISO 9001:2008
DEKRA Certification GmbH bescheinigt hiermit, dass das Unternehmen
All our products are developed and produced in Germany - that is one reason GHM Gruppe, vertreten durch die
is certifi ed according to ISO 9001:2008 and additionally for potentially
explosive atmospheres according to DIN EN 13980:2003. Zertifizierter Standort:
D-88453 Erolzheim, Schloßstrasse 6
ein Qualitätsmanagementsystem entsprechend der oben genannten Norm eingeführt hat und
aufrechterhält. Der Nachweis wurde mit Auditbericht-Nr. A13051144 erbracht.
Conformity with Directive 94/9/EC ('ATEX Directive') has been mandatory for Ex
Dieses Zertifikat ist gültig vom 04.08.2014 bis 23.05.2015 Zertifikats-Registrier-Nr.: 50713437
Zertifikats
Duplikat
Simulator
manufacturing and sales have been certifi ed in accordance with Directive 94/9/
Bei Verstoß gegen die im Zertifizierungsvertrag genannten Bedingungen verliert das Zertifikat umgehend seine Gültigkeit.
EC since 01/05/2003. Several products have already been tested and approved
in accordance with this standard.
Alarm / Protection, Level
2
futher information on www.greisinger.de
General Information
SALES INTERNATIONAL
Handheld instrument
Anita Renc Mariana Giudicelli Parimal Sharma
Display / Controller
Direction sales international Sales Export Sales Export
Schloßstraße 6 Schloßstraße 6 Schloßstraße 6
88453 Erolzheim 88453 Erolzheim 88453 Erolzheim
Germany Germany Germany
Logger / EASYBus
Language: Language: Language:
German | English | Italian | Czech English | Spain | Portugese | German English | Hindi | German
EXPORT PROCESSING
Transmitter
Wolfgang Sonntag Peter Wüster Edith Hiemer
Sales Export Sales Export +49-7354-937233-47
Standort Honsberg Standort Honsberg e.hiemer@ghm-messtechnik.de
Tenter Weg 2-8 Tenter Weg 2-8
42897 Remscheid 42897 Remscheid Michael Glaser
Germany Germany +49-7354-937233-49
m.glaser@ghm-messtechnik.de
+49-2191-9672-62 +49-2191-9672-35
Temperature probe
Ellen Auffurth
w.sonntag@ghm-messtechnik.de p.wuester@ghm-messtechnik.de +49-7354-937233-41
e.auffurth@ghm-messtechnik.de
Area: Area:
South Europe | East Europe Scandinavia | UK | Ireland Regina Stellmach
+49-2191-9672-91
Language: Language: r.stellmach@ghm-messtechnik.de
German | English German | English
FURTHER INFORMATION
Simulator
DE FR
de www.greisinger.net
www.erichsen.fr
Alarm / Protection, Level
Établissement Greisinger
201
016
6 201
015
5
93128 Regenstauf | Hans-Sachs-Straße 26
+49 - 9402 - 9383 - 0 | www.greisinger.de
+49 - 9402 - 9383 - 33 | info@greisinger.de
01/2016 01/2015
3
futher information on www.greisinger.de
LEGEND
Handheld instrument
AUTO AutoRange
RANGE Tare function
The conductivity measurement gets automatically switched to the optimal TARA Displayed value as well as min- and max-values are set to zero.
measuring range. Can be deactivated in the menu.
Battery Change Indicator Real-time clock
BAT Clock with day, month and year
POSSIBLE CONNECTORS
Transmitter
NST1200-connector
used in:
4-pol. bajonett connector GTH 1150 / 70, GMH 1150 / 70, 7-pole diode connector
used in: GMH 3210 / 30 / 50, GIM 3590, used in:
5000er Geräteserie GMH 3330 / 50, GMH 3830 / 51 GLMU 200 / 400
Alarm / Protection, Level
4
futher information on www.greisinger.de
General Information
PRODUCT OVERVIEW
Handheld instrument
SERVICE
28
Kalibrierzeichen / Calibration Mark 13-09
Seite / Page / 1
Werkskalibrierschein / Proprietary Calibration Certificate
Kalibriergegenstand / Calibration item Dieser Werkskalibrierschein
dokumentiert die Rückführung auf
GMH 3710
OEM- / customer-specifi c designs 006
nationale Normale zur Darstellung
GTF 101, DIN Kl. B der Einheiten in Übereinstimmung
Sonderanfertigung / Special design mit dem Internationalen
Einheitensystem (SI).
Am Kalibriergegenstand (KG) ist
Seriennummer / Serial number eine Klebemarke angebracht, die
32402 mit der Kalibriernummer dieses
Werkskalibrierscheines sowie dem
Kalibriermonat und Jahr
versehen wurde.
Hersteller / Manufacturer Für die Einhaltung einer
GHM Messtechnik GmbH angemessenen Frist zur
Wiederholung der Kalibrierung ist
Calibration and certifi cates 007
Standort Greisinger der Benutzer verantwortlich.
Hans-Sachs-Straße 26
93128 Regenstauf
MOBILE MEASUREMENT
Dieser Werkskalibrierschein darf nur vollständig und unverändert weiterverbreitet werden.
Auszüge oder Änderungen bedürfen der Genehmigung des ausstellenden Kalibrierlaboratoriums.
Werkskalibrierscheine ohne Unterschrift haben keine Gültigkeit.
This calibration certificate may not be reproduced other than in full except with the permission of the issuing laboratory.
Calibration certificates without signature are not valid.
Display / Controller
Temperature / Infrared 008-025
Air humidity / Flow rate 026-030
Material humidity 031-038
Water analysis 039-052
Gas 053-058
Pressure 059-070
Miscellaneous 070-071
Logger / EASYBus
Zubehör / Software 072-078
Transmitter
DATA LOGGER / EASYBUS 104
Data logger 105-110
EASYBus overview 111
Accessories 112
Temperature probe
Transmitters:
Temperature, humidity, pressure, conductivity, redox, pH, O2, CO, CO2, fl ow 114-131, 137-144
Sensors
Rational speed sensor, fl ow sensor, fl oat switch, level switch 131-136
SIMULATOR 160
GHM SensorSimulator SIM-1 161
Simulator
EX-PROTECTION
Measuring instruments (Pressure) 061-067
Alarm / Protection, Level
Displays 080, 100
Transmitters 120
Temperature probes 154-155
5
futher information on www.greisinger.de
OEM- / CUSTOMER-SPECIFIC DESIGNS
Handheld instrument
You have not found a device fulfilling all your requirements completely?
No problem, we can modify the devices to your specific needs.
Display / Controller
Logger / EASYBus
To a certain extend the hardware or software can be modifi ed to your requirements.
For example this are realized modifi cations to customer‘s specifi cations:
• Modifying the hardware to another probe characteristic
• Creating an additional material characteristic for the GMH 38xx-series
• Other connectors
• Faster pressure measurement
• ...
If there is no device in our standard product proposal fulfi lling your individual require-
ments, there is the possibility to develop a device according to your specifi cations.
Please note that the customer versions are associated with a little extra costs or
depending on the amount of ordered pieces.
Alarm / Protection, Level
6
futher information on www.greisinger.de
General Information
Handheld instrument
28
Kalibrierzeichen / Calibration Mark 13-09
Seite / Page / 1
1. Readjustment
Which certificate will be required ? Werkskalibrierschein / Proprietary Calibration Certificate
Kalibriergegenstand / Calibration item Dieser Werkskalibrierschein
After a longer period of use, it‘s recommendable
to send in the devices (e.g. humidity) for readjust-
dokumentiert die Rückführung auf
GMH 3710
nationale Normale zur Darstellung
GTF 101, DIN Kl. B der Einheiten in Übereinstimmung
Sonderanfertigung / Special design mit dem Internationalen
Einheitensystem (SI).
Factory Calibration Certifi cate: could be deemed to ment. At this, the device will be fully checked up
Am Kalibriergegenstand (KG) ist
Seriennummer / Serial number eine Klebemarke angebracht, die
32402 mit der Kalibriernummer dieses
Werkskalibrierscheines sowie dem
Kalibriermonat und Jahr
versehen wurde.
be suffi cient, if the devices act as measuring and and new adjusted, if required.
Hersteller / Manufacturer Für die Einhaltung einer
GHM Messtechnik GmbH angemessenen Frist zur
Standort Greisinger28 Wiederholung der Kalibrierung ist
der Benutzer verantwortlich.
Hans-Sachs-Straße 26
93128 Regenstauf 13-09
Werkskalibrierschein / Proprietary Calibration Certificate
which realize the units of
according to DIN EN ISO 9000ff or similar, as long
International Systems of units (SI).
Auftragsnummer / Order number The calibration label fixed to the
001029 / 22.08.2013 calibration item contains number,
Kalibriergegenstand / Calibration item Dieser Werkskalibrierschein month and year of the calibration.
dokumentiert die Rückführung auf The client is responsible for an
GMH 3710 Datum der nationale
Kalibrierung / Date of calibration
as they are not used as a standard. Furthermore
Normale zur Darstellung appropriate calibration interval.
GTF 101, DIN Kl. B 10.09.2013
der Einheiten in Übereinstimmung
there are some measurement categories, without
32402 mit der Kalibriernummer dieses
Dieser Werkskalibrierschein darf nursowie
Werkskalibrierscheines vollständig
dem und unverändert weiterverbreitet werden.
Auszüge oder Änderungen bedürfen
Kalibriermonat und Jahr der Genehmigung des ausstellenden Kalibrierlaboratoriums.
DIN EN ISO 9000ff demands a traceable calibrati-
Werkskalibrierscheine ohne Unterschrift haben keine Gültigkeit.
versehen wurde.
Hersteller / Manufacturer This calibration certificate may not be reproduced other than in full except with
This calibration certificate may not be reproduced other than in full except wit
Für die Einhaltung einer the permission of the issuing laboratory.
Calibration certificates without signature are not valid.
possibility to get a DAkkS accreditation.
GHM Messtechnik GmbH angemessenen Frist zur
Wiederholung der Kalibrierung ist
Standort Greisinger der Benutzer verantwortlich.
Hans-Sachs-Straße 26
on of measuring and test equipment. This calibrati-
Datum Leiter des Kalibrierlabors Sachbearbeiter
93128 Regenstauf
Date Head of calibration laboratory Person responsible
DAkkS-Calibration Certifi cate will be recommended
Auftraggeber / Costumer This calibration certificate documents
the traceability to national standards,
which realize the units of
on certifi cate is a low-priced alternative to the
measurements
10. September 2013 according to the
Stephan Heine Florian Hengl
International Systems of units (SI).
Auftragsnummer / Order number
for the recalibration of testing equipment which itself
Display / Controller
The calibration label fixed to the
001029 / 22.08.2013 calibration item contains number,
month and year of the calibration.
DAkkS Calibration Certifi cate.
Datum der Kalibrierung / Date of calibration The client is responsible for an
appropriate calibration interval.
10.09.2013
is used as a standard for the monitoring of other Anzahl der Seiten / Number of pages
3
measuring and test equipment. It is also possible
Auszüge oder Änderungen bedürfen der Genehmigung des ausstellenden Kalibrierlaboratoriums.
The DAkkS Calibration Certifi cate always conforms
makes a DAkkS Calibration Certifi cate necessary. 10. September 2013 Stephan Heine Florian Hengl
to form, structure and procedures the standards
and requirements of the German Calibration
Service according DIN EN ISO 17025.
1. READJUSTMENT
(without certifi cate of calibration) Readjustment of the device
Logger / EASYBus
2. FACTORY CALIBRATION CERTIFICATE WK
Calibration certifi cates are available for all handheld instruments marked with the symbol WK .
Also possible for measuring transmitters resp. combinations of display instruments and sensors/transmitters.
Transmitter
(Please specify an inspection point) Certifi cate of calibration: 5 points ascending, Certifi cate of calibration with 3 points:
additional measurement point 5 points descending ~147 µS/cm, ~1412 µS/cm, ~12,90 mS/cm
(from -30 ... +500 °C) ISO-WPD10 ISO-WPL10
(Please specify an inspection point) Product-ID: 602565 Product-ID: 602623
additional measurement point Certifi cate of calibration: 10 points ascending, Certifi cate of calibration with 10 points from
(-90 ... -30 and +500 ... +1300 °C) 10 points descending 0.9 µS/cm to ~192 mS/cm
(Please specify an inspection point)
additional measurement point
-196 °C Humidity Ultrapure Water
ISO-WPF4 ISO-WPL3-RW
Temperature probe
ISO-WPT2A
Product-ID: 602583 Product-ID: 602543 Product-ID: 602624
Certifi cate of calibration with standard values: Certifi cate of calibration incl. standard-measuring Certifi cate of calibration with 3 points:
0 °C / +70 °C values (approx. 20 % / 40 % / 60 % / 80 % RH ~2,50 µS/cm, ~7,00 µS/cm, ~15,00 µS/cm
increasing and decreasing; measurement point
ISO-WPT2B Temperature: approx. +23 °C)
Product-ID: 602584
Certifi cate of calibration with standard values: pH
0 °C / +37 °C ISO-WPP3
Atmospheric Oxygen Product-ID: 602767
ISO-WPT3
Product-ID: 602596 ISO-WPO3 Certifi cate of calibration with 3 points:
Certifi cate of calibration with standard values: Product-ID: 602816 4.00 pH, 6.87 pH, 9.18 pH
-20 °C / 0 °C / +70 °C Certifi cate of calibration with 3 points: ISO-WPP10
0 / 20.9 / 100 % O2 Product-ID: 602768
Note: a replacement of the sensor, before issue the Certifi cate of calibration with 10 points from
Simulator
7
futher information on www.greisinger.de
Handheld instrument
GMH 3750
GMH 175
Application:
Transmitter
Reference- /
precision measurement ● ●
Quality management ● ● ● ● ● ● ● ● ●
Difference measurement
Surface measurement
Core temperature
● ● ● ● ● ● ●
Temperature probe
measurement
High-temperature
measurement ● ●
Food, HACCP ● ● ● ● ● ● ●
Water-proof ● ● ●
Handling with one hand ●
Equipment:
Sensor element Pt100 Pt100 Pt1000 Pt1000 Pt1000 Pt1000 Pt1000 Pt1000 Pt1000
Simulator
(max.) Meas. range [°C] -200 ... +850 -200 ... +850 -200 ... +200 -200 ... +250 -70 ... +250 -199 ... +199 -199 ... +199 -200 ... +400 -199 ... +199
Resolution [°C] 0,01 0,01 0,1 0,1 0,1 0,1 0,1 0,1 0,1
Plug-in probe ● ● ● ●
Measurement inputs 1 1 1 1 1 1 1 1 1
Alarm / Protection, Level
Catalogue page 10 10 14 14 14 15 15 12 12
8
further information on www.greisinger.de
Handheld instrument Temperature/Infrared
TEMPERATURE
Handheld instrument
Thermocouple: type K, type N, type S, … Features:
The contact of two different metal compositions (e.g. NiCr and Ni) results • Very small sensors are possible, therefore:
in a voltage between contact spot (probe) and the displaying device. This - Very short response times possible
voltage is almost proportional to the temperature difference and gets - Highly suitable for surface measurements
evaluated and converted to a temperature by the displaying device. • Temperatures up to 1750 °C can be measured
(depending on design of probe and type of used thermocouple)
CONCLUSION: very fast, very fl exible and wide measuring range
Display / Controller
Logger / EASYBus
GTH 200 air
GMH 3210
GMH 3230
GMH 3250
GMH 1150
GMH 1170
GTH 1150
GTH 1170
Application:
Transmitter
Reference- /
precision measurement
Quality management ● ● ● ● ●
Difference measurement ● ●
Surface measurement ● ● ● ● ● ● ●
Core temperature
● ● ● ● ● ● ●
Temperature probe
measurement
High-temperature
measurement ● ● ● ● ● ● ●
Food, HACCP ● ● ●
Water-proof
(max.) Meas. range [°C] -25 ... +70 -220 ... +1750 -220 ... +1750 -220 ... +1750 -50 ... +1150 -50 ... +1150 -65 ... +1150 -65 ... +1150
Plug-in probe ● ● ● ● ● ● ●
Measurement inputs 1 1 2 2 1 1 1 1
Alarm / Protection, Level
Catalogue page 16 17 17 17 18 18 18 18
9
for additional accessories p.r.t. page 72 - 78
PT100 - HIGH-PRECISION THERMOMETER CALIBRATED SYSTEMS
Handheld instrument
AUTO
RANGE
ADDITIONAL FUNCTIONS AT GMH 3750:
Scope of supply:
BAT Measuring device GMH 3750 or GMH 3710, temperature
ALARM LOGG probe GTF 401 1/3 DIN, plastic case GKK 3500 and
certificate of calibration with 3 calibration points.
HOLD
MIN
MAX General:
O / S- The overall error of a measuring consists of the sum of
CORR the instrument error and the probe error. To minimize the
overall error, we offer calibrated and optimized systems
Logger / EASYBus
below.
Due to their excellent system accuracy they are especial-
ly suitable for quality assurance according to ISO9000ff,
as reference instruments in manufacturing processes,
GMH 3710 Power supply: 9 V-battery, as well as additional laboratory, service and maintenance, etc.
Product-ID: 600332 d.c. connector for external The system optimization is done via a special characte-
Pt100 - High-Precision Thermometer, 10.5-12 V voltage supply. ristic curve which is determined for each temperature
Accessories not incl., 4-wire Power consumption: approx. 1 mA probe separately and stored in the instrument (GMH
Housing: Impact-resistant ABS plastic 3750) or with probe adjusting via offset and slope input
GMH 3750 housing, membrane keyboard, (GMH 3710).
Product-ID: 600335 transparent panel. Front side
Pt100 - High-Precision Thermometer,
Accessories not incl., 4-wire, Data logger
IP65, integrated pop-up clip
GMH 3750 / SET1
Dimensions: 142 x 71 x 26 mm (H x W x D) Product-ID: 602690
Weight: approx. 155 g
Transmitter
10
further information on www.greisinger.de
Handheld instrument Temperature/Infrared
Handheld instrument
IMMERSION PROBE FOR LIQUIDS / GASES INSERTION PROBE FOR SOFT MEDIA
GTF 401 GES 401
Product-ID: 600377 Product-ID: 600384
-50 ... +400 °C, DIN class B -50 ... +400 °C, DIN class B
Display / Controller
stainless steel tube (V4A) Ø 3 mm with needle type prod, plastic handle, anti-buckling
non-corrosive stainless steel tube (V4A) Ø 3 mm, plastic handle, anti-buckling glanding, glanding, approx. 1 m 4-wire PVC cable, 4-pin miniature DIN-type plug
approx. 1 m 4-wire PVC cable, 4-pin miniature DIN-type plug Response time T90 water 0.4 m/s approx. 10 s, air 1 m/s approx. 40 s
Response time T90 water 0.4 m/s approx. 10 s, air 1 m/s approx. 40 s
GTF 35
Product-ID: 600391 AMBIENT AIR PROBE
-50 ... +400 °C, DIN class B
GLF 401 Mini
Product-ID: 600395
-25 ... +70 °C, DIN class A
Logger / EASYBus
non-corrosive stainless steel tube (V4A) Ø 3 mm, shrink sleeving, approx. 1 m 4-wire PVC
cable, 4-pin miniature DIN-type plug
V4A tube Ø 1,6 mm, FL = approx. 40 mm, 4-pin mini DIN-type plug
Response time T90 water 0.4 m/s approx. 10 s, air 1 m/s approx. 40 s
Response time T90 air 1 m/s approx. 25 s
IMMERSION PROBE WITH SHEATH ELEMENT PT100 SURFACE PROBE FOR SOLID SURFACES
Advantages of sheath element Pt100: • high temperature resistance GOF 401 Mini
• sheath cable is bendable Product-ID: 600396
• high shock resistance
Transmitter
-50 ... +200 °C, DIN class B
• high service life
Frontal Pt100 ceramic plate 2 x 2,3 mm, V4A tube Ø 2.2 mm, approx. 1 m 4-wire PVC
cable, 4-pin miniature DIN-type plug
Response time T90 approx. 15 s
Temperature probe
V4A sheath tube bendable, Ø 1.6 mm, plastic handle, antikink connection, approx. 1 m
4-pole cable, mini-DIN plug
Response time T90 water 0.4 m/s < 2 s, air 1 m/s approx. 25 s
SPECIAL DESIGNS
stainless steel tube (V4A) Ø 3 mm, plastic handle, anti-buckling glanding,
approx. 1 m 4-wire PVC cable, 4-pin miniature DIN-type plug Upcharges:
Simulator
(casted, only possible with PVC cable -20 ... +105 °C)
higher sensor accuracy:
1/3 DIN class B, for Pt100 and Pt1000, tolerances: 0.1 °C at 0 °C
higher sensor accuracy:
1/10 DIN class B, for Pt100-probes, tolerances: 0.03 °C at 0 °C
V4A-fl ecible jacket tube, Ø 3 mm, plastic handle, anti-buckling glanding, approx. 1 m
4-wire PVC cable, 4-pin miniature DIN-type plug
Response time T90 water 0.4 m/s < 5 s, air 1 m/s approx. 60 s basic fee for custom made probe
11
for additional accessories p.r.t. page 72 - 78
PRECISION THERMOMETER PT1000 RESISTANCE TEMPERATURE MEASUREMENT PT1000
Handheld instrument
ISO FUNCTIONS:
FUNCTIONS: ALARM
AUTO
BAT OFF
BAT
Display / Controller
HOLD
MIN
MAX
BACKLIGHT
GHM 285-KB
GMH 285-KB
Product-ID: 605506
Logger / EASYBus
Alarm thermometer with 3.5 mm jack socket, without accessories
EMC: The device corresponds to the essential protection ratings
established in the Regulations of the Council for the Appro-
ximation of Legislation for the member countries regarding
electromagnetic compatibility (2004/108/EG).
Additional fault: <1 %.
Housing: impact-resistant ABS, membrane keypad, transparent panel,
front side IP65, integrated pop-up clip for table top or suspen-
ded use
Dimensions: without BNC socket: 142 x 71 x 26 mm (H x W x D)
BNC socket: approx. 13 mm long
Alarm / Protection, Level
Weight: approx. 170 g (incl. battery)
Scope of supply: Device, battery, manual
12
further information on www.greisinger.de
Handheld instrument Temperature/Infrared
BLE
ALL PROBES AVAILA
SUITABLE PT1000 - MEASURING PROBES, 2-WIRE NECTOR
ALSO WITH BNC-CON
Handheld instrument
IMMERSION FOR LIQUIDS / GASES SURFACE PROBE FOR SOLID SURFACES
GTF 175 GOF 175
Product-ID: 600423 Product-ID: 600433
-70 ... +200 °C, Pt1000 class B -70 ... +200 °C, Pt1000 class B
non-corrosive V4A tube, Ø 3 mm, plastic handle, anti-buckling glanding, 1 m highly fl exi- S2 x 2.3 mm ceramic Pt1000 sensor mounted at the tip, V4A tube, quadratic 3 x 3 mm
Display / Controller
ble silicone cable, 3.5 mm gold plated jack connector at the tip, plastic handle, anti-buckling glanding, 1 m highly fl exible silicone cable,
Response time T90: water 0.4 m/s < 2 s, air 2 m/s approx. 40 s 3.5 mm gold plated jack connector
Response time T90: approx. 15 s
Logger / EASYBus
Product-ID: 600424
-70 ... +200 °C, Pt1000 class B S2 x 2.3 mm ceramic Pt1000 sensor mounted at the tip, V4A tube Ø 2.2 mm, 1 m highly
fl exible silicone cable, 3.5 mm gold plated jack connector
Response time T90: approx. 15 s
Transmitter
GES 20
Product-ID: 606787 to screw into deep-frozen products, etc. no predrilling required. V4A tube, 6 mm Ø with
-70 ... +250 °C, Pt1000 class B screw prod, 1 m highly fl exible silicone cable, 3.5 mm gold plated jack connector
Response time T90: approx. 15 s
Temperature probe
Response time T90: water 0.4 m/s < 1 s, air 2 m/s approx. 12 s Product-ID: 604659
-50 ... +200 °C, Pt1000 class B
GES 175
Product-ID: 600431
-70 ... +200 °C, Pt1000 class B
V4A-sensor sleeve Ø 5 mm, 3.5 mm gold plated jack connector, 1 m highly fl exible
silicone cable, each beginning meter upcharge
V4A tube Ø 3 mm with slim insertion tip, plastic handle, anti-buckling glanding, Response time T90: water 0.4 m/s < 10 s, air 2 m/s approx. 60 s
1 m highly fl exible silicone cable, 3.5 mm gold plated jack connector
Response time T90: water 0.4 m/s < 2 s, air 2 m/s approx. 40 s
Variant:
Simulator
GTF 2000-WD
Product-ID: 602362
AIR/GAS PROBE FOR CLEAN MEDIA water proof type, construction like described before, but cable of PVC and tube enclosed
water proof. Max. 105 °C!
GLF 175
Product-ID: 600438
-70 ... +200 °C, Pt1000 class B ACCURACY
Pt100 / Pt1000:
sensor accuracy acc. to DIN EN 60751
DIN class B: (area of validity: -50 ... +500 °C) ±0.3 °C at 0 °C
Alarm / Protection, Level
13
for additional accessories p.r.t. page 72 - 78
WATER-PROOF HACCP THERMOMETER WITH PT1000 PROBE
Handheld instrument
ISO
GMH 2710-T
HACCP
FUNCTIONS:
LIQUIDS
AUTO- AIR / GAS
HOLD
Display / Controller
GMH 2710-E
AUTO
BENDABLE
OFF
BAT
SOFT MEDIA
MIN
MAX GMH 2710-K
O / S-
CORR
CORE TEMPERATURE
Logger / EASYBus
Ø 3 MM
WATER-PROOF GMH 2710-G
AND VERY ROBUST
DEVICE AND PROBE
Temperature measuring device incl. Tefl on insertion probe
GMH 2710-K design type with big Tefl on handle and 1 m Tefl on cable, with
GMH 2710-G slim insertion tip, handle and cable are resistant to tempe-
ratures up to 250 °C air temperature. Stainless steel kink
Product-ID: 602040 protection, Ø 3 mm / length: 100 mm
Temperature measuring device incl. mini Tefl on probe
GMH 2710-G design type with small Tefl on handle and 1 m Tefl on cable,
GMH 2710-F with slim insertion tip, handle and cable are suitable for
permanent application at temperatures up to 250 °C.
Product-ID: 604035 Stainless steel kink protection, Ø 1.5 mm / length: 100 mm
Single-hand temperature measurement device with integrated immersion probe
GMH 2710-F V4A mantle tube, bendable, Ø 3 mm, length 150 mm
GMH 2710-I GMH 2710-I V4A mantle tube with needle-shaped insertion tip, bendable,
Product-ID: 604611 Ø 3 mm, length 150 mm
Single-hand temperature measurement device with integrated insertion probe Response time T90: approx. 10 s
Application: Display: two 4-digit LCD (12.4 mm and 7 mm)
Simulator
Weight: 215 g (incl. battery and probe)
These measurements may cause problems with ordinary thermometers.
Scope of supply: device incl. probe, battery, manual
Specifications:
Measuring range:
Accessories and spare parts:
K 50 BL
GMH 2710-T / -E -199.9 ... +200.0 °C
Product-ID: 601352
GMH 2710-K / -G -199.9 ... +250.0 °C Silicone protection cover blue
GMH 2710-F / -I -70 ... +250 °C K 50 RE
Resolution: 0.1 °C Product-ID: 607456
Silicone protection cover red
14
further information on www.greisinger.de
Handheld instrument Temperature/Infrared
Handheld instrument
ISO LIQUIDS
GTH 175 PT-T
AIR / GAS
HACCP
HIGHLIGHTS:
Display / Controller
GTH 175 PT-E
SOFT MEDIA
CORE TEMPERATURE
Ø 3 MM
Logger / EASYBus
GTH 175 PT-G
Transmitter
cable are resistant to air tempera-
GTH 175 PT-E tures up to 250 °C.
Product-ID: 600052 GTH 175 PT-G Probe (V4A, Ø 1.5 mm x 100 mm)
Temperature measuring device incl. insertion probe as above, but with Tefl on handle
and 1 m Tefl on cable. Handle and
28
rk
13-09
cable are resistant to air tempera- Werkskal
ibriersch
ein / Propr
ietary Calib
Dieser
ration
Werksk
Certificate
alibriers
ntiert die
chein
Rückfüh
rung auf
ung
tures up to 250 °C.
Darstell
dokume Normale zur stimmung
le
nationa n in Überein
tion item der Einheite ionalen
d / Calibra Internat (SI).
Product-ID: 600053
enstan mit dem ist
Kalibriergeg GMH 3710 Kl. B l design Einheite
nsystem
rgegens
tand (KG) die
cht,
GTF 101, DINigung / Specia Am Kalibrie arke angebradieses
r
Sonderanfert eine Klebem
Kalibrie
rnumme sowie dem
mit der cheines
alibriers
Werksk und Jahr
rmonat
number Kalibrie wurde.
Display: 3½-stellige, 13 mm high LCD
n
er / Serial versehe ng einer
Seriennumm 32402 Für die
Einhaltu
Frist zur rung ist
Temperature measuring device incl. Tefl on insertion
ssenen Kalibrie
angeme
olung der ortlich.
Wiederh r verantw
mbH der Benutze
cturer
/ Manufa esstechnik G
Hersteller GHM M inger nts
Standort Greis traße 26 te docume
display
achs-S ration certifica l standards,
ibration
Hans-S stauf This cal
ability to
nationa
93128 Regen
the trace units of
g to the
probe
alize the
which re ).
mentss accordin units (SI
er measure tems of
onal Sys d to the
r / Costum Internati abel fixe ,
Auftraggebe
bration l number
The cali contains tion..
on item libration
e calibra
calibrati of the ca
ear of th
nd year
th and y for an
month a ponsible
number nt is res terval.
The clie ration in
mer / Order / 22.08.2013 iate calib
Temperature probe
alibriers te may n are not v
Werksk
ibration
certifica
ithout si
gnature Sachbearbei sible
This cal ficates w respon
Calibrat
ion certi
erlabors Person
Kalibri
Leiter des laboratory
Product-ID: 601836
calibration
Head of
Datum Hengl
Florian
Temperature measuring device incl. mini Tefl on probe
Power supply: 9 V battery (included)
Application: Battery life time: approx. 200 operating hours
Accurate measurements in liquids, as core measuring Housing: Housing made of impact-resistant
device (with insertion probe) or for air/gas measurements. ABS
Handle and cable of -T and -E are resistant to tempera-
Dimensions: approx. 106 x 67 x 30 mm GTH 175 PT-T-WPT2
tures up to 100 °C, -K and -G up to 250 °C.
(H x W x D) Product-ID: 602670
Specifications: Weight: approx. 190 g Complete solution incl. immersion probe and certifi -
(incl. battery and probe) cate of calibration WPT2 A (0 °C / 70 °C) and case
Measuring range: -199.9 ... +199.9 °C
Scope of supply: device incl. probe, battery, manual GKK 252.
Resolution: 0.1 °C
Accuracy: 0.1 % of meas. value ±2 digit Options: GTH 175 PT-T-WPT3
(at nominal (at range: -70.0 ... +199.9 °C), Product-ID: 602673
temperature) Probe and device are calibrated GTH 175 PT-T - WD
Simulator
cable
GB 9 V
GTH 175 PT-E Probe (V4A, Ø 3 mm x 100 mm) Product-ID: 601115
as above, but additional slim Spare battery
insertion tip for all soft media.
Handle and cable are resistant to ST-KR
temperatures up to 100 °C. Product-ID: 601082
Device protection bag with round cut-out (central)
GKK 1100
Product-ID: 601060
Case (340 x 275 x 83 mm) with foam lining
15
for additional accessories p.r.t. page 72 - 78
PRECISION ROOM THERMOMETER HAY THERMOMETER SOIL THERMOMETER
Handheld instrument
FIBERGLAS PROBE
4 METER LONG
AUTO
OFF ALARM ALARM BACKLIGHT
ALARM FUNCTION
BAT
AUTO BACKLIGHT AUTO
OFF OFF
ALARM FUNCTION
MIN BAT BAT
MAX
Display / Controller
HOLD HOLD
MIN MIN
MAX MAX
OF
ROBUST PROBE MADE
STAINLESS STEEL
COMFORTABLE
Logger / EASYBus
ONE HAND
HANDLING WITH ONLY cutting tip
Application: Silo checking, measurements in soils, waste dumps,
The room thermometer GTH 200 air is an essential tool for Application: silages, compost, etc. The alarm function additionally
fast and precise temperature measurements in Measurements at depth up to 4 m. The alarm function allows for acoustic monitoring of the selected temperature
• calibration rooms additionally allows for acoustic monitoring of the selected boundaries. The serial interface in combination with GAM
• production / computer rooms temperature boundaries. The serial interface in combina- 3000 can be used for switching additional alarm devices
• living space tion with GAM 3000 can be used for switching additional or realizing basic control processes. The device is also
• laboratories, etc. alarm devices or realizing basic control processes. The supplied by the GAM 3000: continuous operation possible.
device is also supplied by the GAM 3000: continuous
Specifications: operation possible. Specifications:
Measuring range: -25.0 ... +70.0 °C Device: GMH 285-BNC, see page 12
Specifications:
Resolution: 0.1 °C Probe connection: BNC, Pt1000, 2-wire
Temperature probe
Device: GMH 285-BNC, see page 12
Accuracy: (±1 digit) (at nominal temperature) Measuring range: -50.0 … +250.0 °C
± 0.5 % of meas. value ±0.1 °C Probe connection: BNC, Pt1000, 2-wire
Measuring rod: Stainless steel, 1000 mm x Ø 10
Sensor: Pt 1000, 1/3 DIN class B Measuring rod: Fiberglass probe, approx. 4 m mm, 1 m connection cable with
long, approx. 10 mm Ø, BNC plug, 350 g, probe handle
Response time: T90 = approx. 5 s 1 measuring point at probe tip designed for comfortable use
Display: 4½ digit, 11 mm high LCD-display Cutting tip: screwable, double-edged tip with Scope of supply: Device, GTF 40 T, battery, manual
Nominal temperature: 25 °C integrated temperature sensor
Working temperature: -20 ... +70 °C Weight: Measuring rod with cutting tip Accessories and spare parts:
Working humidity: 0 ... 95 % RH (non condensing) approx. 600 g GMH 285-BNC
Storage temperature: -25 ... +70 °C Scope of supply: Device, fi berglass rod, probe Product-ID: 605507
tip Pt1000, BNC cable (1.5 m), Alarm thermometer with BNC socket
Power supply: 9 V battery battery, manual GTF40T-620
Current consumption: max. 0.1 mA Product-ID: 606803
Battery service time: approx. 6000 operating hours with
Accessories and spare parts: Stainless steel insertion probe, FL 620 mm,
Simulator
16
further information on www.greisinger.de
Handheld instrument Temperature/Infrared
Handheld instrument
HIGHLIGHTS:
• Serial interface
Display / Controller
BAT • Temperature differences
VERY QUICK
Logger / EASYBus
GMH 3210 connection GMH 3250 connection suitable probes p.r.t. p. 20-22!
RESPONSE TIME
Transmitter
Weight: approx. 155 g
Thermocouples: J, K, N, S, T
GMH 3210-B: B, K, N, S, T, Scope of supply: device, battery, manual
Resolution: 0.1 °C or 1 °C
Resolution: 0.1 °C or 1 °C
Measuring range (depending on thermocouples):
Measuring range: -220°C ... +1750°C Accessories and spare parts:
(depending on thermocouples)
GMH 3210: -220 °C ... +1750 °C GB 9 V
Measuring ranges: (extract) Product-ID: 601115
GMH 3210-B: +300 ... +1750 °C Spare battery 9 V
Typ K: (MB1) -199.9 ... +999.9 °C
Measuring ranges: (extract) GNG 10/3000
(MB2) -220 ... +1372 °C
Type K: (MB1) -65.0 ... +300.0 °C Product-ID: 600273
Accuracy: (extract) Plug-in power supply (220 / 240 V, 50 / 60 Hz),
(MB2) -220 ... +1372 °C
Typ K: (für MB1) ±0.03 % of m.v. output voltage: 10.5 V / 10 mA, suitable for
Accuracy: (extract)
Temperature probe
±0.05 % f.s. (T ≥ -60 °C) devices with power supply socket
Type K: (for MB1) ±0.03 % of m.v. ±0.05 % f.s. ±0.2 % of m.v. ST-N1
±0.05 % f.s. (T < -60 °C) Product-ID: 601070
(for MB2) ±0.08 % v. MW. ±0.1 % f.s.
(für MB2) ±0.08 % of m.v. Nappa leathern device protection bag with 1 rectangular
Working temperature: -25 ... +50 °C
±0.1 % f.s. (T ≥ -100 °C) cut-out for sensor connection
Probe connections: 1 ±1 °C ±0.1 % f.s. (T < -100 °C) suitable for: GMH 3210
Display: two 4-digit LCDs Working temperature: -25 ... +50 °C ST-N2
(12.4 mm and 7 mm high) Product-ID: 601072
Probe connections: 2
Output: 3-pin jack connector Ø 3.5 mm, Nappa leathern device protection bag with 2 rectangular
Display: two 4-digit LCD displays cut-outs for sensor connection
confi gurable
(12.4 mm and 7 mm high) suitable for: GMH 3230, GMH 3250
Serial interface: direct connection to RS232 or
Serial interface: 3-pole jack socket Ø 3.5 mm, GKK 3500
USB interface of a PC via electri-
direct connection to RS232 or Product-ID: 601052
cally isolated interface adapter
USB interface of a PC via electri- with punched lining for 1 device (394 x 294 x 106 mm)
GRS 3100 or GRS 3105 resp.
cally isolated interface adapter
USB 3100 N (p.r.t. accessories).
GRS 3100 or GRS 3105 resp.
Simulator
buttons or interface)
Power consumption: approx. 0.3 mA cyclic:
Housing: impact resistant ABS plastic case, 9.999 data sets (fetch data via
membrane keyboard, transparent interface)
panel, front side IP65, integrated adjustable cycle time: 1 s … 1 h
pop-up clip The logger is started or stopped
by keypad or interface. The
Dimensions: 142 x 71 x 26 mm (H x W x D)
software GSOFT3050 (see acces-
Weight: approx. 155 g sories) is available for comfortable
Scope of supply: device, battery, manual read-out of logger data.
17
for additional accessories p.r.t. page 72 - 78
QUICK RESPONSE THERMOMETER TYPE K PRECISION QUICK RESPONSE THERMOMETER TYPE K
Handheld instrument
BAT BAT
Display / Controller
FUNCTIONS:
AUTO MIN
OFF BAT HOLD
O / S-
GMH 1150 CORR GMH 1170
MAX
Logger / EASYBus
ST-KN ST-N1
Product-ID: 601080 Product-ID: 601070 28
13-09
device protection bag, suitable for GTH 1150 device protection bag, suitable
rk
tion Ma
en / Calibra /1
Seite / Page
Kalibrierzeich
icate
ration Certif
ein / Proprietary Calib
ibriersch
for GMH 1170
chein
Werkskal
Werksk
alibriers rung auf
Dieser Rückfüh ung
ST-N1
ntiert die Darstell
dokume Normale zur stimmung
le
nationa n in Überein
tion item der Einheite ionalen
d / Calibra mit dem
Internat (SI).
enstan ist
Kalibriergeg GMH 3710 Kl. B l design Einheite
nsystem
rgegens
tand (KG) die
cht,
GTF 101, DINigung / Specia Am Kalibrie arke angebradieses
r
Sonderanfert eine Klebem rnumme sowie dem
Product-ID: 601070
mit der cheines
alibriers
Werksk und Jahr
rmonat
number Kalibrie wurde.
n
er / Serial versehe ng einer
Seriennumm 32402 Für die
Einhaltu
ssenen
Frist zur rung ist
angeme Kalibrie
olung der ortlich.
Wiederh r verantw
Product-ID: 602675
mbH der Benutze
device protection bag, suitable for GMH 1170
cturer
/ Manufa esstechnik G
Hersteller GHM M inger nts
Standort Greis traße 26 certifica
te documerds,
achs-S ibration national standa
Hans-S stauf This cal
ability to
93128 Regen
the trace units of
alize the g to the
which re ).
ments accordin units (SI
measure tems of
Complete Solution incl. immersion probe
er onal Sys d to the
/ Costum
ggeber
Internati abel fixe ,
bration l number
Auftra The cali
on item
contains
libration
.
calibrati of the ca
nd year for an
month a ponsible
number nt is res terval.
terval
The clie ration in
mer / Order / 22.08.2013 iate calib
Auftragsnum 001029 appropr
ion
GTF 900 and certifi cate of calibration WPT
calibrat
/ Date of
ierung
der Kalibr 10.09.2013
Datum
r of pages .
/ Numbe t werden oriums.
erbreite
der Seiten 3 dertt weiterv Kalibrierlaborat
Anzahl eränder ry.
unverän laborato
dig und des ausstellenden issuing
ion of the
(with meas. points: 0 / 100 / 250 / 500 °C)
nur vollstän igung eit. permiss
chein darf n der Genehm keine Gültigk wit the
with
pt with
alibriers l except
full exce
Dieser
Werksk ngen bedürfe hrift haben other than in ful
Änderu
e oder ohne Untersc roduced
Auszüg cheine ot be rep alid. ter
alibriers te may n are not v
Werksk
ibration
certifica
ithout si
gnature Sachbearbei sible
This cal ficates w respon
Calibrat
ion certi
erlabors Person
Kalibri
Leiter des laboratory
and case GKK 1100.
calibration
Head of
Datum Hengl
Date Florian
e
Stephan Hein
r 2013
10. Septembe
18
further information on www.greisinger.de
Handheld instrument Temperature/Infrared
Handheld instrument
Display / Controller
ED
RECOMMEND S
EF
BY HEAD CH
Logger / EASYBus
STARTER-SET
FOR MANY
MEASURING TASKS
Transmitter
Ready-to-use universal temperature measuring set with Ready-to-use temperature measuring set with a universal This combination often used by top chefs is recommended
3 different type K temperature sensors. Perfectly suitable insertion probe plus a wire probe in a case for measuring the core temperature of meat, cooking oil,
for measurements in liquids, air and gases as well as etc. The thin needle will barely damage the meat. The core
surfaces. Specifications: temperature measurement range of -65 ... +400 °C can be
GMH 1170: see page 19 determined very quickly.
Specifications:
GTF 300: see page 22 Specifications:
GMH 3210: see page 17
GES 900: see page 21 GTH 1150: see page 18
GTF 300: see page 22
Scope of supply: Device, wire probe, insertion pro- GTE 130-OK: see page 22
GTF 400: see page 20 be, plastic case, battery, manual
GOF 500: see page 20 Scope of supply: Device, probe, battery, manual
Accessories and spare parts:
Temperature probe
Scope of supply: GMH 3210 – temperature me- Accessories and spare parts:
asuring device, GTF 300 – wire GMH 1170
probe, GTF 400 – immersion Product-ID: 600113 GTH 1150
probe for gases and liquids, GOF Precision quick-response thermometer Product-ID: 600047
500 – surface probe, GKK1105 – Quick-response thermometer
GTF 300
plastic case, battery, manual Product-ID: 600072 GTE 130-OK
Wire probe Product-ID: 601483
Accessories and spare parts: Insertion probe
GES 900
ISO-WPT Product-ID: 600518 ST-KN
Product-ID: 604652 Insertion probe Product-ID: 601080
according to DIN ISO 9000 Device protection bag with rectangular cut-out for sensor
Test points -20 °C, +70 °C, +200 °C depending on probe GKK 1105 connection
Product-ID: 601050
GMH 3210 Case with cut-outs for 1 device of GMH 3xxx or 5xxx GKK 252
Product-ID: 600337 series Product-ID: 601056
Precision quick-response thermometer Case with foam lining for universal use
For calibration certifi cates see page 7.
Simulator
Product-ID: 601050
Case with cut-outs for 1 device of GMH 3xxx series
19
for additional accessories p.r.t. page 72 - 78
TYPE K - MEASURING PROBE (NICR-NI) WITH DIN-TYPE FLAT-PIN PLUG
Handheld instrument
L 135 1000
non-corrosive V4A tube Ø 1,5 mm, L=130 mm, plastic handle, anti-buckling glanding, 2 laser welded NiCr-Ni resilient springs, V4A-tube Ø 8 mm, plastic handle, anti-buckling
1 m silicone cable, Miniature fl at plug glanding, 1 m silicone cable, Miniature fl at plug
Response time T90: water 0.4 m/s approx. 3 s Response time T90: water 0.4 m/s approx. 2 s
L 135 1000
non-corrosive V4A tube Ø 3 mm, L=130 mm, plastic handle, anti-buckling glanding, 2 laser welded NiCr-Ni resilient springs, V4A tube gebogen, plastic handle, anti-buckling
1 m silicone cable, Miniature fl at plug glanding, 1 m silicone cable, miniature fl at plug
Response time T90: water 0.4 m/s < 2 s, air 2 m/s approx. 40 s Response time T90: water 0.4 m/s approx. 2 s
GOF 200 HO
Product-ID: 600492
IMMERSION PROBE WITH SHEATHED THERMOCOUPLE -65 ... +400 °C
GTF 1200
Product-ID: 600507 BENDABLE
-200 ... +1150 °C,
for fastest measurements in small gaps
Ø 1,5
Small elbow-type, fl exible thermocouple tapes, plastic handle, anti-buckling glanding,
1 m silicone cable, miniature fl at plug
Transmitter
GTF 1200/300
Product-ID: 600510 BENDABLE
-200 ... +1150 °C POTENTIAL FREE
Ø3
Temperature probe
Flexible thermocouple tapes, plastic handle, anti-buckling glanding, 1 m silicone cable,
miniature fl at plug
for aluminium melt, non-ferrous metal, etc. Response time T90: water 0.4 m/s approx. 2 s
V4A tube Ø 6 x 1.4 mm, L=1000 mm rigid, additional internal mantle thermocouple, plastic MH 400VE
handle, anti-buckling glanding, 1 m silicone cable, Miniature fl at plug Product-ID: 607502
Response time T90: water 0.4 m/s approx. 30 s magnet holder, heat resistant up to 100 °C
GOF 500
Product-ID: 600488
-65 ... +500 °C
Alarm / Protection, Level
ACCURACY
Thermocouples:
sensor accuracy acc. to DIN EN 60584-2
class 1 for Type K: ±1.5 °C at range -40 ... +375 °C for any straight and solid surface; solid copper plate, plastic handle, anti-buckling
class 1 for Type N: ±1.5 °C at range -40 ... +375 °C glanding, 1 m silicone cable, miniature fl at plug
class 1 for Type S: ±1 °C at range 0 ... 1100 °C
Response time T90: water 0.4 m/s approx. 5 s
20
further information on www.greisinger.de
Handheld instrument Temperature/Infrared
Handheld instrument
GOF 500 HO GES 900
Product-ID: 600498 Product-ID: 600518
-200 ... +500 °C, (potentialfrei) -65 ... +1000 °C
Ø3
130 135 1000
Spring-loaded V4A tube with slim Ø 3 mm insertion tip, plastic handle,
for any straight and solid surface anti-buckling glanding, 1 m silicone cable, miniature fl at plug
Small elbow-type, solid copper plate, Ø 1,5 MTE (K) Inconel 600 bendable, plastic handle, Response time T90: water 0.4 m/s approx. 5 s
anti-buckling glanding, 1 m silicone cable, Miniature fl at plug
Display / Controller
Response time T90: approx. 5 s
AIR/GAS PROBE
GOF 130 CU
Product-ID: 600486 GTL 130 VERY FAST
-65 ... +500 °C Product-ID: 602304
-65 ... +600 °C
Ø6
130 135 1000
for any straight and solid surface for room temperature, fl ue gases, etc.
Spring-loaded copper plate, plastic handle, anti-buckling glanding, 1 m silicone cable, perforated V4A protective tube, fused thermocouple wires arranged behind, plastic
miniature fl at plug handle, anti-buckling glanding, 1 m silicone cable, miniature fl at plug
Logger / EASYBus
Response time T90: approx. 5 s Response time T90: air 2 m/s approx. 1.5 s
split-second response time, yet highly resilient
Use for canteen kitchen, backeries, butcher´s shops, etc. V4A tube Ø 8 mm reduced to Ø 3 mm at the front, plastic handle, anti-buckling glanding,
Transmitter
V4A tube with Ø 1.5 mm slim insertion tip, small Tefl on handle, stainless steel kink 1 m silicone cable, miniature fl at plug
protection, 1 m Tefl on cable, miniature fl at plug Response time T90: water 0.4 m/s approx. 6 s
Response time T90: water 0.4 m/s < 1 s, air 2 m/s approx. 12 s
Temperature probe
Use for canteen kitchen, backeries, butcher´s shops, etc.
V4A tube Ø 3 mm with needle-shaped insertion tip, big white Tefl on handle, stainless steel
kink protection, 1 m Tefl on cable, miniature fl at plug for liquid or soft media etc.
V4A tube 8 mm dia. reduced to 3 mm, plastic handle, anti-buckling glanding, spiral cable
Response time T90: water 0.4 m/s < 2 s, air 2 m/s approx. 40 s
stretchable to 1.2 m, DIN-type fl at-pin plug
Response time T90: water 0.4 m/s approx. 6 s
Simulator
V4A tube with Ø 1.5 mm slim insertion tip, plastic handle, anti-buckling glanding, 1 m fast response insertion probe with stop screw (needle adjustable 0 ... approx. 14 mm).
silicone cable, miniature fl at plug Suitable for measuring temperature of tires and other soft media. plastic handle, anti-
buckling glanding, spiral cable (approx. 1.2 m drawn out), miniature fl at plug
Response time T90: water 0.4 m/s approx. 3 s
Response time T90: approx. 5 s
GES 500
Product-ID: 600516
CLIP-ON PROBE
Alarm / Protection, Level
-65 ... +550 °C
GTZ 300
Ø3
Product-ID: 603287
-65 ... +150 °C
130 135 1000
V4A tube with Ø 3 mm with needle-shaped insertion tip, plastic handle, anti-buckling for temperature measurements at tube surfaces
glanding, 1 m silicone cable, miniature fl at plug for tubes up to approx. 25 mm Ø, 1 m silicone cable, miniature fl at plug
Response time T90: water 0.4 m/s approx. 5 s Response time T90: approx. 3 s
21
for additional accessories p.r.t. page 72 - 78
TYPE K - MEASURING PROBE (NICR-NI) WITH DIN-TYPE FLAT-PIN PLUG
Handheld instrument
Ø 1,5
Product-ID: 600072 Product-ID: 600141
Measuring tip twisted/fused -50 ... +250 °C
Measuring tip with weld bead
-65 ... +300 °C, insulation up to +250 °C
SOLDERING TIP PROBE
GLS 500
Product-ID: 602962
-50 ... +500 °C
Product-ID: 602554
twisted measuring tip GTO 130 OK
Product-ID: 600134
GTF 300 GS -UV -65 ... +400 °C
Product-ID: 607893
Measuring tip non-twisted/fused
INSERTION PROBE
Transmitter
100
MAGNETIC SURFACE PROBE (interchangeable probe without cable) for soft media
Spring-loaded V4A tube with slim Ø 1.5 mm insertion tip, miniature fl at plug with a rigid
GMF 250 connection
Product-ID: 600071 Response time T90: approx. 3 s
Temperature probe
-65 ... +250 °C
IMMERSION PROBE
GTT-15-150
Ø 1,5
Product-ID: 607552
-200 ... +1150 °C
self-adhesive on magnetic materials, spring-loaded CU plate Ø 5 mm, 1 m,
Tefl on-insulated twisted cable, miniature fl at plug
150
Response time T90: approx. 5 s
for air, gases, and liquids
GMF 200 Sheathed thermocouple with Inconel 600 jacket tube Ø 1.5 mm, bendable, miniature fl at
Product-ID: 601377 plug with a rigid connection
-65 ... +200 °C Response time T90: water 0.4 m/s approx. 3 s
Simulator
GGF 200
Product-ID: 603418
-65 ... +200 °C Probe tip must not be held directly into the fl ame
V4A tube Ø 8 mm, with reduced Ø 5.5 mm ceramic tube, plastic handle, silicone cable,
miniature fl at plug
Response time T90: approx. 2 s
to screw into deep-frozen products, etc. no predrilling required, V4A-tube, 6 mm Ø with
screw prod, spiral cable (approx. 1.2 m drawn out), DIN-type fl at-pin plug
Response time T90: approx. 15 s
22
further information on www.greisinger.de
Handheld instrument Temperature/Infrared
INFRARED
Handheld instrument
Infrared measurement
Infrared measurements can be used to measure
the temperature of a surface on a device under
test without the need to come into contact with
that surface (except objects with a shiny metal
surface; glass suitable under certain conditions).
The IR sensor measures the infrared radiation
emitted by the device under test. The measure-
ment is supported by a laser which designates
the surface measured by the optical measuring
system.
Properties:
• Ultrafast and contactless surface measurement
Display / Controller
• For measurement tasks that cannot be
accomplished using PT100 or type K devices
(e.g. abrasive chemicals, small components, ...)
Logger / EASYBus
GIM 530 MS
GIM 3590
MT 400
Application: ST 512
Transmitter
Precision measurement ● ●
Fast scanning of surfaces ● ● ● ●
Food ● ● ● ●
Quality management ● ● ● ●
Temperature probe
Equipment:
Optical resolution
(Distance / Spot size) 8:1 20:1 30:1 75:1
Catalogue page 24 24 25 25
23
for additional accessories p.r.t. page 72 - 78
INFRARED THERMOMETER INFRARED THERMOMETER WITH PRECISION GLASS OPTIC
Handheld instrument
HIGHLIGHTS:
BAT BAT • Fast scanning of hot and cold spots within 0.3 s
HOLD HOLD
MIN MIN
MAX MAX
optical diagram:
MT 400 ratio: spot size / distance
Infrared measurement is not suitable for liquids and specular or reflective surfaces
24
further information on www.greisinger.de
Handheld instrument Temperature/Infrared
Handheld instrument
FUNCTIONS: FUNCTIONS:
ALARM ALARM
HOLD HOLD
• Alarm function
Display / Controller
D
INCL. SOFTWARE AN
OL
CALIBRATION PROTOC
UT
THERMOCOUPLE INP
Logger / EASYBus
Application: General:
• Monitoring of circuit boards: overheated parts The measured point will be marked exactly with the precision of a laser cross-hair. The
• Heating / ventilation / air-conditioning: detecting bad isolation, untight pipes, energy integrated sharp point optics allows measurements of even smallest measuring objects
consumption, general service measurements, etc. down to 1 mm. Its position sensor turns the display always to the most comfortable
• Electrical systems, machines, power engines: detecting hot spots at electric connec- orientation.
tions, temperature rises at motors, bearings, pumps, compressors, etc. • switchable focus point optics
• Food processing and monitoring: food temperature, process temperature, etc. • laser cross-hair shows real measuring point size
• Medical technology, biological and chemical analysis: contact-free temperature • Flip-display
measurements within seconds, no longer problems with dangerous, aggressive or • additional thermocouple input
similar media • USB interface and graphical software
• Industry, engineering, craft: Surface temperature measurements of rotating parts
(barrels, drums, shafts, printing machines, plastic welding, bitumen, concrete, etc.) Specifications:
Measuring range: -35.0 ... +900.0 °C (IR and thermocouple type K)
Specifications:
TC input: thermocouple type K
Transmitter
Measuring range: -50 ... +1000 °C
Resolution: 0.1 °C
Resolution: 0.1 °C
Accuracy IR: ±0.75 °C or ± 0.75 % of m.v.
Accuracy: -50 °C ... -23 °C ±7 °C (typical)
(at ambient temperature = -23 °C ... -2 °C ±4 °C Accuracy type K: ±0.75 K or ± 1 % m.v. (at 23 °C ± 5 °C)
23 °C ... 25 °C) -2 °C ... +94 °C ±2.5 °C Response time (t95): 150 ms
94 °C ... 204 °C ±(1.0 % of meas. value + 1 °C) Optical resolution: 75:1 16 mm @ 1200 mm
204 °C ... 426 °C ±(1.5 % of meas. value + 1 °C)
426 °C ... 1000 °C ±(3 % of meas. value+1 °C) at focus point optic: 1 mm @ 62 mm
Reproducibility: ±0.5 % of meas. value or ±1 °C Rate of emission: 0.100 ... 1.100, selectable
Response time (T95): 150 ms Measuring functions: MAX / MIN / HOLD / DIF / AVG / °C / °F
Emission rate: 0.10 … 1.00, selectable Alarm functions: acoustic / visual high-low-alarm
Temperature probe
Spectral range: 8 ... 14 µm Display: LC Flipwith position sensor / bar graph
Optical resolution (D / S): approx. 30:1 Backlight: green or alarm colours (red / blue)
Visiereinrichtung: dual laser Spectral range: 8 - 14 µm
Stromversorgung: 9 V battery Working temperature: 0 ... 50 °C
Display: LCD-display with function indicator symbols and Relative humidity: 10 ... 95 % RH (non condensing)
background illumination Data logger: 100 measurements protocols
Working conditions: 0 °C ... 50 °C, 10 ... 90 % RH Interface: USB
Storage temperature: -10 ... +60 °C Software: oscilloscopstyle software, 20 readings / s
Features: HOLD, Min- / Max, °F, LOCK, Alarm Voltage supply: 2 x AA alkaline battery or USB
Alarm function: selectable min / max alarm, with integrated buzzer Weight: 420 g
Dimensions: 146 x 104 x 43 mm Scope of supply: Device incl. USB cable & software, bag, insertion probe type
Weight: 163 g K, batteries, carrying loop, calibration protocol, transport case
Simulator
S 20 16 40 70 100 130 mm
Standard
D 0 1200 2000 3000 4000 5000 mm
Infrared measurement is not suitable for liquids and specular or reflective surfaces
25
for additional accessories p.r.t. page 72 - 78
HUMIDITY /
Handheld instrument
FLOW RATE
Display / Controller
Logger / EASYBus
+ TFS 0100 E
+ TFS 0100 E
GMH 3330
GMH 3350
GFTH 200
GFTB 200
GFTH 95
Application:
Air conditioning /
● ● ● ● ●
Transmitter
Meteorology ●
Room climate ● ● ●
Flow measurement ● ●
Air pressure measuring ●
Temperature probe
Calculation of:
Dew point Td ● ● ● ●
Wet bulb temperatur Twb ● ●
Moisture content x /
Absolute humidity d ●
Dew point distance /
Enthalpy ● ●
Simulator
Ausstattung:
Alarm ● ●
Data logger ●
Device information:
Catalogue page 28 28 30 30 27
26
further information on www.greisinger.de
Handheld instrument flow rate, material moisture
Handheld instrument
ISO ADDITIONAL DISPLAY
METERS,
FOR FURTHER PARA
FUNCTIONS: ERATURE
E.G. DEW POINT TEMP
ITY
AUTO AND ABSOLUTE HUMID
OFF
BAT
Display / Controller
HOLD
MIN
MAX
PC INTERFACE
O / S- ALARM FUNCTION
CORR ZZER
WITH INTEGRATED BU
Logger / EASYBus
Digital-Hygro-/Thermo-/Barometer Configurable display: choice between automatically displaying all values rotationally
(cycle of 2 or 4 s) or manual selection, units not needed can
General: be excluded
The GFTB 200 is designed for measuring air pressure, air humidity and temperature Offset und Scale: digital offset- and scale adjustment of measurements
within seconds. It reaches remarkable accuracy because of its high precision sensors.
The dew point temperature monitoring with GFTB 200 provides effi cient protection from Tendency indicator: Air pressure rising/falling (for barometer)
moisture damage potentially caused by condensation water and therefore helps preven- Sea level correction: Barometric values can be converted to sea level
ting mold infestation. The integrated alarm function can be used to acoustically remind the (therefore the input of the current altitude is needed).
user to ventilate in order to optimally and effi ciently use heating energy. The integrated Housing: Housing made of impact-resistant ABS
interface together with the software EBS 20M (optional) allow the use as mobile weather
station with additional long-term recording. The GFTB 200 can precisely and clearly Dimensions: approx. 106 x 67 x 30 mm (H x W x D), additionally the
display the air condition with parameters like wet bulb temperature, absolute humidity and sensor head at the front side, 35 mm long, Ø 14 mm;
moisture content of the air. resulting total length 141 mm
Weight: approx. 130 g incl. battery
Application:
Transmitter
Scope of supply: Device, battery, manual
• mobile weather station
• housing space, indoor swimming pools Variante:
• offi ces and production rooms, laboratories, storage rooms
GFTB 200-KIT
• museums, gallery, churches
Product-ID:600890
• cooling and climate technology
Digital-Hygro-/Thermo-/Barometer with USB-interface kit, consisting of:
• construction, building physics, loss assessment
• USB interface converter USB 3100 N
• multi channel software EBS20M (to record all device units)
Specifications:
Measuring ranges: Accessories and spare parts:
Temperature: -25.0 °C ... +70.0 °C GKK 252
Product-ID: 601056
Temperature probe
Air humidity: 0.0 ... 100.0 % RH (recommended range: 11 … 90 % RH)
case (235 x 185 x 48 mm) with foam lining
Air pressure: 10.0 ... 1100.0 mbar
ISO-WPF4
Calculated parameters: Product-ID: 602543
Dew point temperature Td: -40.0 ... +70.0 °C Certifi cate of calibration, humidity, for ISO9000ff (p.r.t. page 7)
Wet bulb temperature Twb: -27.0 ... +70.0 °C ISO- WPD5
mixing ratio x: 0.0 ... 280.0 g/kg Product-ID: 602514
Certifi cate of calibration, pressure, for ISO9000ff (p.r.t. page 7)
Absolute humidity d: 0.0 ... 200.0 g/m³
Resolution: 0.1 % RH; 0.1 °C or 0.1 °F, 0.1 mbar
Accuracy: (±1 digit) (at nominal temperature = 25 °C)
Temperature: ±0.5 % v. MW. ±0.1 °C (Pt1000 1/3 DIN B) HIGHLIGHTS:
Air humidity: ±2.5 % RH (at range 11 ... 90 %)
• easy and fast search for thermal
Air pressure: ±1.5 mbar (750 ... 1100 mbar)
bridges
Simulator
Sensors:
Temperature: Pt1000 • targeting laser for precise location
Air humidity: capacitive polymer humidity sensor even of inaccessible areas
Air pressure: piezo-resistive sensor hybrid
• audible alarm below dewpoint
Response time: T90 = 10 s
Display: 4½ -digit, approx. 11 mm high LCD-display with additional
displays
Operation elements: 3 keys for ON/OFF, min/max value display, hold GFTB 200 SET
Alarm / Protection, Level
27
for additional accessories p.r.t. page 72 - 78
HUMIDITY, TEMPERATURE AND FLOW RATE MEASURING DEVICE
Handheld instrument
E,
W POINT TEMPERATUR
CALCULATION OF DE NCE
ISO DEW PO INT DIS TA
AND ENTHALPY
STANDARD-
FUNCTIONS:
AUTO
OFF ATURE INPUT (TYPE
K)
ADDITIONAL TEMPER
Display / Controller
BAT
MIN
MAX ALARM LOGG
Logger / EASYBus
temperature:
rk
tion Ma
en / Calibra /1
Seite / Page
Kalibrierzeich
pensation value can be set for surface measurement if
icate
ration Certif
ein / Proprietary Calib
ibriersch
chein
Werkskal
alibriers rung auf
necessary.
le
nationa n in Überein
tion item der Einheite ionalen
d / Calibra mit dem
Internat (SI).
enstan ist
Kalibriergeg GMH 3710 Kl. B l design Einheite
nsystem
rgegens
tand (KG) die
cht,
GTF 101, DINigung / Specia Am Kalibrie arke angebradieses
r
Sonderanfert
(p.r.t. next page)
eine Klebem rnumme sowie dem
Kalibrie
mit der cheines
Flow measurements:
alibriers
Werksk und Jahr
rmonat
number Kalibrie wurde.
n
er / Serial versehe ng einer
Seriennumm 32402 Für die
Einhaltu
ssenen
Frist zur rung ist
angeme Kalibrie
olung der ortlich.
Wiederh r verantw
mbH der Benutze
cturer
/ Manufa esstechnik G
Two different systems for averaging are integrated:
Hersteller GHM M
Resolution:
inger
0.1 % RH, 0.1 °C / 0.1 °F, 0.01 m/s
nts
Standort Greis traße 26 te docume
achs-S ration certifica l standards,
ibration
Hans-S stauf This cal
ability to
nationa
93128 Regen
the trace units of
alize the g to the
which re )).
ments accordin units (SI
er measure tems of
onal Sys d to the
r / Costum Internati abel fixe ,
calibrat
/ Date of
averaging time set.
alibriers
Dieser
Werksk ngen bedürfe hrift haben other than in ful
Änderu
e oder ohne Untersc roduced
Auszüg cheine ot be rep alid. ter
alibriers te may n are not v
Werksk
ibration
certifica
ithout si
gnature Sachbearbei sible
This cal ficates w respon
Calibrat
ion certi
erlabors Person
Kalibri
28
further information on www.greisinger.de
Handheld instrument flow rate, material moisture
Handheld instrument
HUMIDITY / TEMPERATURE FLOW SPEED
Display / Controller
(0.0 ... 100.0 % RH) (0.05 ... 5.00 m / s)
Humidity / temperature probe, exchangeable Flow measuring probe with snap-on head, exchangeable
General: Specifications:
Hand sensor for universal application Sensor type: windmill-type anemometer
cap with integral stainless steel gauze fi lter for good mechanical protection and despite Measuring range: 0.05 ... 5.00 m / s (water)
optimum airfl ow also for fast measurements in ambient air
Accuracy: ±1 % of range ± 3 % of meas. value
Specifications: (at nominal temperature = 25 °C)
Measuring ranges: Permiss. angle flow: ±20°, without additional measuring faults
Humidity: 0.0 ... 100.0 % RH (rec. range of application: 11 ... 90 % RH) Working temperature: -10 ... +80 °C
Temperature: -40.0 ... +120.0 °C Relative humidity: 0 ... +100 % RH (non-condensing)
(attention: working temperature of electronics!) Dimensions: Probe head: Ø 11 x 15 mm, tube: Ø 15 mm,
Logger / EASYBus
Accuracy: (at nominal temperature = 25 °C) overall length 165 mm,
required insertion opening: Ø 16 mm,
Humidity: ±2.5 % RH approx. 5 m PVC connection cable with 6-pin Mini-DIN-plug
Temperature: ±0.5 °C Weight: approx. 75 g
Sensors: Scope of supply: sensor, manual
Humidity: capacitive polymer humidity sensor
Temperature: Pt1000, 1/3 DIN Accessories and spare parts:
Electronics: PC board with amplifi er and data memory for sensor data STE 005
(calibration, etc.) integrated in probe handle. Product-ID: 602406
Spare snap-on head for STS 005
Working temperature: -25 ... +60 °C (handle and electronics)
-40 ... +100 °C (for short time up to +120 °C) STS 005-GTS
(sensor head and tube) Product-ID: 602645
GTS Telescopic rod (overall length 1 m)
Relative humidity: 0 ... +100 % RH
Transmitter
Dimensions: Probe tube: Ø 14 x 119 mm,
plastic handle: Ø 19 x 135 mm, approx. 1.2 m PVC
connection cable with 6-pin Mini-DIN-plug FLOW / AIR
Weight: approx. 90 g
Scope of supply: sensor, manual
Variant:
TFS 0100 E-POR
Product-ID: 606784
Humidity / temperature sensor with plastic paper fi lter
for use in dusty environments and also in powder
Temperature probe
colors and granulates STS 020
Product-ID: 602397
GFN-SET1 (0.55 ... 20.00 m / s)
Flow measuring probe with snap-on head, calibrated and exchangeable.
Product-ID: 602708
Humidity reference cells for ~33 and ~76 %RH, Specifications:
probe adapter and robust carry case Sensor type: windmill-type anemometer
General: Measuring range: 0.55 ... 20.00 m / s (air)
Humidity reference cells works on the basis of physiochemical processes. Accuracy: ±1 % of range ± 3 % of meas. value
A specifi c value of relative humidity adjusts itself over a saturated salt (at nominal temperature) = 25 °C)
solution. The test chamber is separated from the solution by a Permiss. angle flow: ±20°, without additional measuring faults
diaphragm so that the sensor under test is protected against contamination
by the solution. The test container can be used in all mounted positions. Working temperature: -10 ... +80 °C
Relative humidity: 0 ... +100 % RH (non-condensing)
Accessories and spare parts:
Simulator
Dimensions: Probe head: Ø 11 x 15 mm, tube: Ø 15 mm,
GFN 33 overall length 165 mm,
Product-ID: 602715 required insertion opening: Ø 16 mm,
humidity reference cell for ~33 % RH, incl. adapter approx. 5 m PVC connection cable with 6-pin Mini-DIN-plug
GFN 76 Weight: approx. 75 g
Product-ID: 602717 Scope of supply: sensor, manual
humidity reference cell for ~76 % RH, incl. adapter
Accessories and spare parts:
SURFACE TEMPERATURE: STE 020
Product-ID: 602519
Alarm / Protection, Level
GTF 300
Product-ID: 600072
(p.r.t. page 22)
Quick-response basic thermocouple probe for universal applications
(surface measurement) picture shows GTS with assembled STS 020
29
for additional accessories p.r.t. page 72 - 78
HUMIDITY/TEMPERATURE
MEASURING DEVICE HUMIDITY / TEMPERATURE / DEW POINT MEASURING DEVICE
Handheld instrument
EXTERNAL PT1000
ISO ISO E CONNECTABLE
TEMPERATURE PROB
FUNCTIONS: FUNCTIONS:
BAT BAT
HOLD
Display / Controller
MIN
MAX
RELATIVE HUMIDITY,
O / S-
CORR TEMPERATURE AND
ONE INSTRUMENT
DEW POINT IN JUST
GFTH 200
30
further information on www.greisinger.de
Handheld instrument flow rate, material moisture
MATERIAL MOISTURE
Handheld instrument
Display / Controller
Logger / EASYBus
+ appropriate electrode
+ appropriate electrode
BaleCheck 100
BaleCheck 200
GMH 3810
GMH 3830
GMH 3851
GMK 210
GMK 100
GMR 110
GMI 15
Transmitter
Application:
Temperature probe
Wood chips ● ●
Plaster, screed, concrete,
bricks, lime mortars ● ● ● ● ● ●
Construction-damage assess-
ment / Water damage restoration ● ● ● ● ● ●
Hay bale / bale of straw/
Corn (barley, wheat) ● ● ● ●
Equipment:
User curves 4
Catalogue page 33 33 32 37 37 34 34 38 38
31
for additional accessories p.r.t. page 72 - 78
INDICATOR FOR MOISTURE IN WOOD AND BUILDINGS
Material Moisture Measurement with
Handheld instrument
handheld instruments
FUNCTIONS:
Methods
BAT
• Resistive measuring method
(GMR 110, GMH 3810, GMH 3830, GMH 3851)
The electrical resistance often depends on the material moisture. Therefore
the devices measure the (possibly extremely high) values of resistance
and convert them to the displayed value by means of integrated characte- EASY AND FAST
Display / Controller
ristic curves. The temperature has to be compensated especially at the
measurement of wood – all GREISINGER- instruments have an integrated MOISTURE RATING
temperature compensation. In most cases the contact is realised by nails
that are driven into the material are used to contact.
(GMK 210, GMK 100, GMI 15)
The dielectric properties of an object are often a good indicator for its
material moisture. The dielectric coeffi cient of water is considerably higher
than that of dry lumbers or building materials. Therefore the total dielectric
coeffi cient of the measuring object can be easily used to get its material
moisture. For the measurement the device has to be applied on the
Logger / EASYBus
material.
Precondition therefore: planar surfaces, no metallic elements. NONDESTRUCTIVE
MEASUREMENT
• relative humidity
(i.e. mit GMH 3330 + TFS 0100 E)
Another method is to measure the material moisture indirectly by means
of the relative humidity: The humidity in a sealed hole within a material GMI 15
depends on the material moisture. By means of a so-called sorption Product-ID: 600059
isotherm or a corresponding table the material moisture can be calculated Indicator for moisture in wood and buildings
from the humidity. General:
Device for high-speed determination of moisture in buildings, contracting work etc. The
• dry method GMI 15 allows detection of moisture in wood down to a depth of approx. 3 cm and in con-
Transmitter
crete or wash fl oor down to a depth of approx. 4 cm. Detection of moisture behind ceramic
The oven dry method can be used for reference point measurement with tiles and/or various wall or fl oor coverings.
highest accuracy. To check moisture simply place device on the surface to be measured - no injection into
The moist material is weighed and afterwards dried at increased tempera- the measuring object required. The displayed values by „digit“ are relative, that means the
values can be well compared.
ture until no weight loss is detectable anymore. The material moisture can
be calculated from the moist and arid weight. Application:
Humidity indication for i.e. estate agents (for fast control state of buildings), property
management, house owners, architects, building experts, building contractors, etc.
Note:
The GMI 15 is an indicator for the fast estimation - it does not replace precision instruments
like the GMH 3810, GMH 3830, GMH 3851 or GMK 100.
Temperature probe
Units
Specifications:
• Material moisture u (also „atro“ ): Display: 3½-digits, 13 mm high LCD
Display range:
relating to dry mass concrete / floor 0 ... 5 = dry
material moisture u [%] = pavement: 6 ... 9 = humid,
(mass wet - mass dry ) / mass dry * 100 normal humidity level
Particularly important for carpenters, joiners, etc. 10 ... = wet
wood / fibre glass 0 ... 3 ~ 0 ... 12 % : dry
• Moisture content w: reinforced polyester: 3 ... 6 ~ 12 ... 20 % : air-dry
6 ... 11 ~ 20 ... 30 % : wind-dry
material moisture related to wet total mass 11 ... ~ 30 % ... : wet
moisture content w [%] = Power supply: 9 V-battery
(mass wet - mass dry ) / mass wet * 100
Simulator
For further information on this topic please see the devices’ manuals
and our homepage
www.greisinger.de under Download -> Documents
32
further information on www.greisinger.de
Handheld instrument flow rate, material moisture
MEASURING DEVICE MOISTURE MATERIAL MOISTURE MEASURING DEVICE
IN WOOD AND BUILDINGS FOR CARAVAN AND BOAT
Handheld instrument
NONDESTRUCTIVE NONDESTRUCTIVE
FUNCTIONS: FUNCTIONS:
MEASUREMENT MEASUREMENT
AUTO AUTO
OFF OFF
BAT BAT
HOLD HOLD
Display / Controller
FOR WOOD AND
BUILDING MOISTURE
FOR CARAVAN SEARCH MODE FOR
& BOAT
QUICKLY LOCATING
HIGHLIGHTS: E
HUMIDITY AND THE LIK
HIGHLIGHTS:
• Moisture display in percent
• Moisture display in percent
Logger / EASYBus
• Acoustical and visual moisture rating
• Acoustical and visual moisture rating
• 18 material characteristics for wood
and building materials • 14 material characteristics for wood and GFK
Transmitter
cation, it is possible to display the material moisture “u” or the water content “w”. cation, it is possible to display the material moisture “u” or the water content “w”.
The humidity is measured by a measuring plate on the back of the device. With a The humidity is measured by a measuring plate on the back of the device. With a side-
side-mounted switch the measuring depths can be changed. With the help of measure- mounted switch the measuring depth can be changed. With the help of measurements in
ments in different depth a statement could be made if for example the material dries different depth a statement could be made if for example the material dries already or if
already or if the moisture is just on the surface of the material. the moisture is just on the surface of the material.
Application: Application:
Humidity measurement and indication of wood, concrete, screed, plaster, etc. Humidity measurement and indication of wood and GFK (glass fi ber reinforced plastic)
Specifications: Specifications:
Display: 2 displays for material and measured value, in % material Display: 2 displays for material and measured value, in % material
Temperature probe
moisture or in % moisture content, backlight moisture or in % moisture content, backlight
Moisture rating: Moisture rating:
Visual: Rating of the moisture in 6 levels from WET to DRY Visual: Rating of the moisture in 6 levels from WET to DRY
Acoustic: Signal tone Acoustic: Signal tone
Measurement depths: 10 mm and 25 mm Messtiefen: 10 mm and 25 mm
Curves: 18 characteristic curves for wood (with assignment tabel for Curves: 14 characteristic curves for wood (with assignment tabel for
wood species) and popular materials, additionally reference wood species) and GFK, insulating materials i.e. Styropor;
curve (rEF) for high-resolution relative measurements additionally reference curve for high-resolution relative
Working temperature: -25 ... +50 °C (not frozen) measurements
Storage temperature: -25 ... +70 °C Working temperature: -25 ... +50 °C (not frozen)
Power supply: 9 V battery Storage temperature: -25 ... +70 °C
Power consumption: approx. 0.12 mA Power supply: 9 V battery
Power backlight: approx. 2.5 mA (Auto-Off) Power consumption: approx. 0.2 mA
Simulator
33
for additional accessories p.r.t. page 72 - 78
PRECISION MATERIAL MOISTURE MEASURING DEVICE FOR WOOD, BUILDING MATERIALS,
STRAW, HAY, PAPER, TEXTILES, ETC.
Handheld instrument
HIGHLIGHTS:
STANDARD-
FUNKTIONS: • serial interface or analog output 0-1 V,
freely scalable
AUTO
OFF • 4 programmable characteristics (GMH 3851)
AUTO-
HOLD • incl. calibration protocol
BAT
Display / Controller
LOGG
ACTERISTICS
466 WOOD TYPE CHAR
TERIALS MPA certified appr. for glued timber
28 CONSTRUCTION MA construction acc. to DIN 1052-1
Logger / EASYBus
Specifications: edited and stored to the instrument.
(Required accessories: interface converter)
Measuring principle:
Average value of 3 measurements, e.g. for professional fi rewood moisture
Moisture: Resistive material moisture measurement measurements
acc. to DIN EN 13183-2:2002
Data logger:
Temperature: This instrument is essential for the documentation of material state by quality assurance
external: thermocouple, NiCr-Ni (type K) systems, etc. By means of the integrated data logger there can be up to 10.000 measu-
internal: NTC ring values recorded and processed on demand. Additionally it is possible to individually
program 4 material curves (e.g. with dry oven or CM-method). This instruments fi nally
Characteristic curves : 494 material characteristics makes paper correction tables unnecessary.
Measuring range: Logger function
Moisture: 0.0 …. 100 % u (material moisture) manual: 99 data sets (fetch data via buttons or interface)
0.0 … 50 % w (water content, wet basis) cyclic: 10.000 data sets (fetch data via interface)
(depends on selected characteristic) adjustable cycle time: 1 s … 1 h
The logger is started or stopped by keypad or interface.
Simulator
34
further information on www.greisinger.de
Handheld instrument flow rate, material moisture
ACCESSORIES
Handheld instrument
1 8 14
Display / Controller
2 9 15
GHE 91 GSP 91
Product-ID: 601262 GMS 300/91 Product-ID: 601301
Product-ID: 601289
Reciprocating piston electrode * sensor for surface measurements *
to drive measuring nails into material without auxiliary devices
Measuring rods
on paper, textiles etc.
300 mm long (pair), for wood chips, wood wool,
paper, carton, etc. (for use with GSG 91 or GSE 91)
3 GSP 91 ES
Product-ID: 601303
Logger / EASYBus
GSE 91 10 spare sensor element
Product-ID: 601266 for GSP 91
Impact electrode * 16
to drive measuring nails into material
GST 15B
Product-ID: 601281
4
steel nails *
2 steel nails with bore hole, 15 mm long, Ø 3.8 mm
GMZ 38
Product-ID: 605783
GEG 91 (for direct connection of measuring cable GMK 38)
Measuring clamp *
Product-ID: 601268
Handle GST 25B for measurements of veneers or thin wood
(up to approx. 10 mm)
Product-ID: 601283
Transmitter
suitable for GSE 91
steel nails * as above, Ø 3.8 x 25 mm 17
5
GST 40B
Product-ID: 601285
GSG 91 steel nails * as above, Ø 3.8 x 40 mm
Product-ID: 601270
Penetration electrode *
GSF 50 (110 cm)
11 Product-ID: 601306
adequate for steel nails and measuring rods
GSF 50K (43 cm)
Temperature probe
6 Product-ID: 601308
GBSK 91 Injection probe
Product-ID: 601293
(without temperature sensor) for measurement up to a
GST 91 Wire brush (pair) short * depth of 40 cm or 107 cm, incl. 1 m connection cable.
Product-ID: 601273 for depths up to approx. 100 mm Suitable for: wood chips, wood wool, straw, hay, grain,
saw dust, etc.
steel nails
9 steel nails (3 pieces each, 12, 16 and 23 mm long) in 12 18
plastic case, Ø 2.5 mm
GST 91/40
Product-ID: 601275 GBSL 91
Product-ID: 601294
Simulator
steel nails
10 steel nails, 40 mm long, Ø 2.5 mm, in plastic case
Wire brush (pair) long *
for depths up to approx. 300 mm GSF 50TF (110 cm)
Product-ID: 601312
7
13
GSF 50TFK (43 cm)
Product-ID: 601314
GST 45i Injection probe
Product-ID: 601277
steel nails
GEF 38 (with temperature sensor) for measurement up to a depth
of 40 cm or 107 cm, incl. 1 m connection cable. Suitable
Alarm / Protection, Level
Product-ID: 601296
2 Tefl on isolated steel nails, 45 mm long, Ø 2.5 mm for: wood chips, wood wool, straw, hay, grain, saw dust,
Flat electrode (pair) * etc.
for screed, paper, etc.
GST 60i
Product-ID: 601279
steel nails, as above, 60 mm lang
* Measuring cable necessary for GHE 91, GSE 91, GSG
91, GST 15B / 25B / 40B, GBSK 91, GBSL 91, GEF 38,
GLP 91, GSP 91, GMZ 38
35
for additional accessories p.r.t. page 72 - 78
ACCESSORIES ACCESSORIES-SETS MOISTURE COMPLET SET
Handheld instrument
19
NEW !
GSF 40 (67 cm)
Product-ID: 601316
Injection probe
(without temperature sensor) for measurement of pressed
bales up to a depth of 60 cm, incl. 1 m connection cable. E
Display / Controller
(with temperature sensor) for measurement of pressed wood
bales up to a depth of 60 cm, incl. 1 m connection cable.
Suitable for: pressed hay or straw bales, grain GMH 38-LW1-TF
Product-ID: 606470
21
GMH 38-LW1-TFK
Product-ID: 606462
(recommended for wood moisture measurements)
GPAD 38 Specifications:
Product-ID: 601328 Device: GMH 3830 GMH 3851 respec-
Test adapter tively, see page 34
(with 2 reference values) for testing GMH 38xx and Penetration: GSF 50, GSF 50K, GSF 50TF,
GMR 110 GSF 50TFK, see page 35
Scope of supply:
24 GMH 38-LW1-TF GMH 3830, GSF 50 TF, battery,
manual
Simulator
25 Content:
pict.: GMH3830 • GKK 3500 (case)
in ST-RN • GMK 38 (measuring cable)
• GHE 91 (reciprocating piston electrode)
ST-RN • GST 91 (measuring nails)
Product-ID: 601074 • GTF 38 (temperature probe)
36
further information on www.greisinger.de
Handheld instrument flow rate, material moisture
RESISTIVE MATERIAL-MOISTURE
MEASURING DEVICE RESISTIVE MATERIAL-MOISTURE MEASURING DEVICE
Handheld instrument
ATURE
HIGHLIGHTS: AUTOMATIC TEMPER
FUNKTIONS: FUNKTIONS: COMPENSATION
• 494 characteristic
AUTO- curves AUTO-
HOLD HOLD
• incl. calibration
AUTO AUTO
protocol
OFF OFF
HOLD HOLD
Display / Controller
FOR WOOD AND
BUILDING MATERIALS
GMH 3810
Product-ID: 600350
Resistive material-moisture measuring device with
integrated measuring pins
ACTERISTIC
General: COMFORTABLE CHAR
DISPLAY
The measuring pins integrated on the reinforced front CURVE- AND RATED
numerous measurings can be done without additional rear side of
device
Logger / EASYBus
accessories.
For measuring of very hard materials we suggest the GMR 110
components shown at the accessories section. Product-ID: 600101
Resistive material moisture measuring device with
Specifications: integrated measuring needles.
Measuring principle:
General: Housing: Impact-resistant ABS plastic
moisture: resistive material-moisture- housing, membrane keyboard,
Compact and robust measuring device for fast evaluation
measuring according to DIN EN transparent panel. Front side IP65
of material moisture in fi rewood, timber, fl ake board, inlay,
13183-2:2002
plaster, cement and lots more. A suitable characteristic Dimensions: 110 x 67 x 30 mm + needles
temperature internal: NTC is selected with help of material table on the rear side of 26 mm
Curves: 494 material characteristics the device before measuring. The material is contacted Weight: approx. 155 g
by pressing the measuring needles into it. The measured
Measuring range: Scope of supply: device, 2 needle protection caps,
value is displayed only a short time afterwards. The device
moisture: 0.0 ... 100.0 % moisture content is especially designed for precise fi rewood and timber me- battery, manual
0.0 ... 50.0 % water content
Transmitter
asurements, however, a lot of additional building materials
(depending on characteristic curve) can be rated. Characteristic curves:
temperature: -25.0 ... +50.0 °C • Material tables on rear side of device 3 wood groups:
(-13.0 ... +122.0 °F) • Integrated, exchangeable measuring needles h.01 spruce, pine
• Moisture rating (wet/dry) via bar graph h.02 maple, birch, beech, larch (EUR),
Estimation: in 9 steps (dry ... wet) ash (EUR), fi r
• Display of material moisture or water content
Resolution: 0.1 % resp. 0.1 °C (0.1 °F) • Integrated temperature compensation h.03 oak, ash (AM), poplar, douglas fi r
Accuracy device: (at nominal temperature = 25 °C) • Characteristic curve display a lot of additional wood types can be determined with the
table of the instruction manual
wood: ±0.2 % moisture content Specifications: 8 building material curves:
(deviation from characteristic c.01 cement screed, concrete
curve at range 6 ... 30 %) Measuring principle: resistive material moisture mea-
surement acc. to DIN EN 13183 c.02 anhydrite screed
building material: ±0.2 % moisture content c.03 plaster, lime mortar
Temperature probe
(deviation from characteristic Characteristic 3 different wood groups (h.01, h.02, c.04 cement mortar
curve) curves: h.03) for a total of 130 wood types c.05 gas concrete
and 8 different building material c.06 lime sand brick
Temperature automatically or manual curves (c.01, c.02, c.03, c.04, c.05,
compensation c.07 clay brick
c.06, c.07, c.08) c.08 gypsum plaster
Measuring probe: 2 pin holders M6 x 0.75 with Measuring range: 0.0 ... 100 % material moisture
19 mm pins (12 mm utilisable) (depends on selected characte- Accessories and spare parts:
Perm. working 0 ... 50 °C (not frozen) ristics) GST 3810
temperature Moisture rating: in 6 steps (wet … dry) Product-ID: 601392
Storage temperature: -25 ... +70 °C replacement pins (10 pcs.)
Resolution: 0.1 % (< 20 %), 1 % (> 20 %)
Rel. humidity: 0 ... 95 % RH (non-condensing) GMK 3810
Accuracy: (at nominal temperature = 25 °C)
Display: two 4-digit LCDs Product-ID: 603070
wood: ±0.2 % material moisture 1 m connection cable with 2 x banana plugs
Sort: the material selection is restricted (Deviation to wood characteristic and 2 adapters. Allows connection of accessories (except
to up to 8 favorites curve in range 6 … 20 %) GSF38..., GTF38 and GES38) on GMH3810 / GMR110.
Simulator
Power supply: 9 V battery building ±0.2 % material moisture additional special accessories at page 35.
Power consumption: approx. 2.5 mA materials: (Deviation to corresponding
GB 9 V
characteristic curve)
Housing: Impact-resistant ABS plastic Product-ID: 601115
housing, membrane keyboard, Temperature automatically or manual spare battery
transparent panel. Front side IP65, compensation:
GKK 252
integrated pop-up clip Measuring probe: 2 needle holder M6 x 0.75 with Product-ID: 601056
Dimensions: 142 x 71 x 26 mm (H x W x D) 19 mm measuring needles case (235 x 185 x 48 mm) with foam lining
(12 mm usable length)
Weight: 175 g
Perm. working -5 ... +50 °C (not frozen)
Scope of supply: Device, battery, manual
Alarm / Protection, Level
temperature:
Accessories and spare parts: Storage temperature: -25 ... +70 °C
GST 3810 Rel. humidity: 0 ... 95 % RH (non condensing)
Product-ID: 601392 Display: 2 LCD displays for characteristic
replacement pins (10 pcs.) and measuring value
GMK 3810 Power supply: 9 V battery
Product-ID: 603070 Current approx. 1.8 mA
with 2 x banana plugs
1 m connection cable with 2 x banana plugs consumption:
and 2 adapters. Allows connection of accessories (except
GSF38..., GTF38 and GES38) on GMH3810 / GMR110.
37
for additional accessories p.r.t. page 72 - 78
HAY AND STRAW HUMIDITY MEASURING DEVICE
HAY AND STRAW HUMIDITY MEASURING DEVICE INCL. TEMPERATURE MEASUREMENT
Handheld instrument
FUNKTIONS:
HIGHLIGHTS: FUNKTIONS: HIGHLIGHTS:
AUTO-
HOLD • robust 60 cm V4A measuring rod AUTO- • fast temperature measurement
HOLD integrated
AUTO
• characteristics for hay, straw and
OFF AUTO
grain OFF • robust 60 cm V4A measuring
Display / Controller
HOLD rod
HOLD
• characteristics for hay, straw
and grain
Logger / EASYBus
BaleCheck 200
Product-ID: 600354
Hay and straw humidity measuring device incl. temperature measurement
(incl. measuring rod and protective bag)
General:
The BaleCheck 200 is a professional measuring device for measuring the moisture in bales
of pressed hay and straw. It allows to very precisely determine the suitability for storage and
quality of hay and straw as well as grain – important especially in agriculture, stock breeding
Transmitter
Application: Specifications:
• agriculture Measuring range: 0.0 …. 100.0 % u (material moisture)
• processing or storing of hay or straw 0.0 … 50.0 % w (water content)
• hay and straw trading -40.0 … +200.0 °C (device)
• stock breeding
• horse keeping Resolution: 0.1 %, 0.1 %
Characteristics: hay, straw, grain, reference characteristics
Specifications: approx. 480 additional material moisture characteristics
Measuring range: 0.0 …. 100 % u (material moisture) Moisture rating: 9-step bar graph (wet … dry)
0.0 … 50 % w (water content)
Temperature automatic or manual
Resolution: 0.1 % (till 19,9 % ) and 1 % (from 20 %) compensation:
Characteristics: hay, straw, grain, reference characteristics Display: two 4-digit LCD displays (12.4 mm and 7 mm)
Moisture rating: 6-step bar graph (wet … dry) Housing / weight: impact-resistant ABS, 142 x 71 x 26 mm (H x W x D), 155 g
Temperature manual
Simulator
38
further information on www.greisinger.de
Handheld instrument water analysis
CONDUCTIVITY
Handheld instrument
Display / Controller
Logger / EASYBus
GLF 100 RW
GMH 5430
GMH 5450
GMH 3431
GMH 3451
GLF 100
Transmitter
Application:
Waters measuring, fishkeeping,
aquafarming (fresh- / marine waters) ● ● ● ● ●
Drinking water-, process monito-
ring, ground measurements ● ● ● ● ●
Cleaning processes ● ● ● ● ● ●
Ultrapure water ● ● ●
Temperature probe
Food production and -control ● ● ● ● ●
Quality management ● ● ● ● ● ●
Water-proof ● ●
Electrodes for replacement ● ●
Equipment:
Measuring range
Conductivity / Temperature ● ● ● ● ● ●
● ● ● ● ●
Simulator
esp. Resistance
TDS / Salinity ● ● ● ● ●
Sensor connection 7-pole bayonet 7-pole bayonet fi xed fi xed fi xed fi xed
Electrode 2-pole stainless
2- or 4-pole 2- or 4-pole 2-pole graphite 4-pole graphite 2-pole graphite
steel
Min/Max, Hold,
General functions Min/Max, Hold, Auto-Off, Calibration Min/Max, Hold, Min/Max, Hold, Min/Max, Hold, Min/Max, Hold,
Auto-Off Auto-Off Auto-Off Auto-Off Auto-Off
Alarm / Protection, Level
memory
Interface ● ● ● ●
Alarm / Data logger ● ●
Device information:
Catalogue page 40 40 42 42 43 43
39
for additional accessories p.r.t. page 72 - 78
WATER-PROOF HANDHELD DEVICE FOR CONDUCTIVITY MEASUREMENT
Handheld instrument
ISO
HIGHLIGHTS:
STANDARD-
FUNKTIONS: • Measurement of conductivity, resistance, salinity, TDS
OFF
BAT
MIN
MAX
ALARM LOGG
Logger / EASYBus
WATER-PROOF
NNECTIONS
DEVICE AND PLUG CO
Connection:
Software for long-term monitoring (p.r.t. page 76)
Conductivity, 1 x 7-pole bayonet connector for connection of different
GSOFT 3050
temperature: measuring cells, supported temperature sensors: Pt1000 or
Product-ID: 601336
NTC (10 k)
Software for operation of logger devices (p.r.t. page 77)
Interface / ext. supply: 4-pole bayonet connector for serial interface and supply
USB 5100
(with accessory: USB adapter USB 5100)
Product-ID: 601095
Analog output: 0 - 1 V, freely adjustable, connection with 4-pole bayonet Electrically isolated interface converter, supplied via USB
(only GMH 5450) connector, resolution 13 bit, accuracy 0.05 % at nominal
GNG 5 / 5000
temperature
Product-ID: 602287
Datenlogger: Zyklisch: 10.000 Datensätze, Zyklus wählbar: 1 s … 60 min
Alarm / Protection, Level
Plug-in power supply 5 V DC, suitable for devices of the series GMH 5000 (p.r.t. page 74)
(nur GMH 5450) Einzel: 1000 Datensätze (mit Messstelleneingabe, 40 einstell-
GKK 3500
bare Messstellentexte oder Messstellennummern)
Product-ID: 601052
Display: 4 ½ digit 7-segment, illuminated (white) Device case (394 x 294 x 106 mm) with eggcrate foam and cut-outs
Operating conditions: -25 ... +50 °C, 0 ... 95 % RH (non-condensing) for 1 device (p.r.t. page 72)
Storage temperature: -25 ... +70 °C
Background illumination: duration adjustable (off, 5 s ... 2 min.)
Power supply: 2 x AAA battery (included),
power consumption 6.25 mA
40
further information on www.greisinger.de
Handheld instrument water analysis
HANDHELD INSTRUMENTS INCL.
CONDUCTIVITY ELECTRODES ELECTRODE
Handheld instrument
PURE AND ULTRA ALCOHOL,
PURE WATER FUEL, DIESEL
Display / Controller
LF 200 RW LF 210
Product-ID: 602841 Product-ID: 602969
conductivity electrode conductivity electrode
Specifications: Specifications:
Measuring range: 0 ... 100 µS/cm Measuring range: 0 ... 1000 µS/cm
Temperature range: -5 ... +100 °C Temperature range: -5 ... +100 °C i. e. GMH 5450
Cell constant *: approx. 0.1 Cell constant *: approx. 1
Temperature NTC 10 k Temperature NTC 10 k
measurement: measurement: READY-TO-USE
Shaft: Stainless steel, Ø 12 mm x 75 mm Shaft: Glass, Ø 12 mm x 120 mm
Electrode: 2-pole stainless steel Electrode: 2-pole glass / platinum
Logger / EASYBus
LF 400
Application: Pure and ultra pure water Application: Alcohol, fuel, diesel
cable length: 1 m cable length: 1 m
LF 425
GMH 5430-400
Product-ID: 602752
FOR UNIVERSAL Handheld instrument incl. electrode LF 400
Transmitter
APPLICATION
TIGHT TOLERANCES
,
GMH 5450-400
ROBUST AND PRECISE Product-ID: 602754
Handheld instrument incl. electrode LF 400,
with data logger
LF 400 LF 425
Product-ID: 602968 Product-ID: 602840 GMH 5430-425
conductivity electrode conductivity electrode Product-ID: 602753
Handheld instrument incl. electrode LF 425
Specifications: Specifications:
Measuring range: 0 ... 200 mS/cm Measuring range: 0 ... 1000 mS/cm GMH 5450-425
Temperature probe
Temperature range: 0 ... 100 °C Temperature range: -10 ... +80 °C (90 °C - max. 5 min) Product-ID: 602755
Cell constant *: approx. 0.55 Cell constant *: approx. 0.42 Handheld instrument incl. electrode LF 425,
with data logger
Temperature NTC 10 k Temperature Pt 1000
measurement: measurement: General:
Dimensions: Epoxide, Ø 12 mm x 120 mm Dimensions: PVC-C, Ø 16 mm x 145 mm All sets get preadjusted and are ready-for-use.They do not
Characteristics: 4-pole graphite Characteristics: 4-pole graphite include a case.
Applications: Universal application, Applications: Tight tolerances, robust and Accessories and spare parts:
Economy Class precise for highest demands,
High End Class GKK 3500
cable length: 2 m Product-ID: 601052
cable length: 1 m Case with foam lining and cut-outs for 1 device
* Note: (394 x 294 x 106 mm) (p.r.t. page 72)
The particular cell constant (appears in calibration pro- Accessories and spare parts:
tocol and electrode‘s label) has to be entered to device. GEH 1
Then it is ready-to-use.
Simulator
Product-ID: 601089
Electrode holder for measuring electrodes with plastic
handle (p.r.t. page 72)
GKL 100
Product-ID: 601396
Conductivity control solution
(100 ml bottle with 1413 µS/cm according to DIN EN
27888)
GKL 101
Product-ID: 601398
Alarm / Protection, Level
Conductivity control solution (250 ml bottle with 84 µS/cm)
GKL 102
Product-ID: 601400
Conductivity control solution (100 ml bottle with 50 µS/cm)
41
for additional accessories p.r.t. page 72 - 78
CONDUCTIVITY MEASURING DEVICE
Handheld instrument
ITY,
ISO DISPLAY OF RESISTIV
SALINITY OR TDSTDS
STANDARD-
FUNCTIONS:
AUTO
OFF
AUTO
Display / Controller
GULATIONS
RANGE
CONFORM TO THE RE
TER ORDINANCE
OF THE DRINKING WA
BAT DIN EN 27888
(TRINKWV 2001) AND
HOLD
MIN
MAX ADDITIONAL FUNCTIONS GMH 3451:
ALARM LOGG
Logger / EASYBus
Resistivity: 0.005 ... 100.0 kOhm * cm
Salinity is understood to be the sum of concentrations of all salts dissolved in water.
Salinity: 0.0 ... 70.0 g / kg water Displayed in g/kg.
TDS: 0 ... 1999 mg/l TDS-determination (total dissolved solids):
Accuracy: (±1 digit) (at nominal temperature = 25 °C) The dry residue of fi ltrate is understood to be the concentration of substances dissolved in
a liquid. Displayed in mg/l
Conductivity: ±0.5% of m.v ±0.3 % FS or ±2 µS/cm
Temperature: ±0.2% of m.v ±0.3 K Additional functions GMH 3451:
Cell correction: adjustable 0.800 ... 1.200 cm-1, manually or automatically with Analog output:
selectable reference solution 0 - 1 V, freely scalable, connection via 3-pole jack socket
Temperature off or automatically Ø 3.5 mm, resolution 13 bit, accuracy 0.05 % at nominal temperature
compensation: (by temperature sensor integrated to electrode) 4-pole measuring cell:
Better long-term stability at high conductivity values (>20 mS / cm) and for harsh environ-
Type of compensation: -nLF: Non-linear function of natural waters ments, stable measuring values even in polluted media (e.g. sewage, salt water)
acc. to DIN EN 27888 (ISO 7888) data logger:
(Reference temperature selectable: 20 °C or 25 °C) cyclic 10,000 data sets, manual: 1,000 data sets (with measuring point input,
-Lin: linear compensation from 0.3 ... 3.0 % / K
Simulator
40 adjustable measuring point texts or measuring point numbers)
(Reference temperature selectable: 20 °C or 25 °C)
-off: no compensation. Option:
Display: two 4-digit LCD displays (12.4 and 7 mm high) for current LTG
conductivity (resistivity, salinity, TDS) and temperature, or for for organic matter (alcohol, petrol, diesel)
min-, max- value, hold function, etc. and additional indicator up to 1000 µS/cm with glass shaft, platinum electrodes,
arrows. 1.35 m PUR-cable permanently connected to device
Measuring cell: Conductivity measuing cell with integrated temperature sen-
sor in shaft. Electrode material: graphite. Shaft material: PPE, Accessories and spare parts:
PS (GMH 3431), Epoxide (GMH 3451). GKL 100
The graphite electrodes are the optimum solution for sewage
Alarm / Protection, Level
Product-ID: 601396
and can be cleaned easily. 100 ml conductivity test solution
Warranty for sensor 12 months (100 ml bottle with 1413 µS/cm, acc. to DIN EN 27888)
element:
Working conditions: device: -25 ... +50 °C, 0 ... 95 % RH; measuring cell:
-5 ... +80 °C (permanent), up to +100 °C (short-term)
Relative humidity: 0 ... +95 % RH (non condensing)
Interface: serial interface; connectable to RS232 or USB interface of
PCs via electrically isolated interface converter GRS 3100,
GRS 3105 or USB 3100 N (accessories).
42
further information on www.greisinger.de
Handheld instrument water analysis
Handheld instrument
ISO ISO
FUNCTIONS: FUNCTIONS:
AUTOMATIC
CHANGE-OVER
MEASURING RANGE
AUTO AUTO
OFF OFF
HOLD HOLD
Display / Controller
MIN MIN
MAX MAX
ATURE
AUTOMATIC TEMPER
CO ENSATION VIA
MP
ATURE SENSOR
INTEGRATED TEMPER
Logger / EASYBus
GLF 100 GLF 100 RW The measuring cell:
Product-ID: 600109 Product-ID: 600111 The measuring head is designed without compromise.
Universal conductivity measuring device Conductivity meter for ultra-pure water The holes ensure the well exchange of the measuring
(incl. calibration protocol) fl uid, nonetheless the sensor is protected against mecha-
nical loads.
Application: Application: The integrated temperature sensor has very quick
• Fresh and sea water aquaristics • Checking of pure and ultra-pure water response time. Compared to simpler electrode designs the
Transmitter
• Fish farming / water monitoring • Checking of boiler water measurements are much more accurate and faster.
• Drink water monitoring, etc. • Functional check of ion exchangers
GLF 100:
Graphite used as material for
Specifications: GLF 100 GLF 100 RW
the electrodes makes the
Measuring ranges: applicability up to 100 mS/cm
Conductivity: 0 ... 2000 µS/cm 0.000 ... 2.000 µS/cm possible - a must have in
0.00 ... 20.00 mS/cm 0.00 ... 20.00 µS/cm seawater analytic
0.0 ... 100.0 mS/cm 0.0 ... 100.0 µS/cm
GLF 100 RW:
Temperature: -5.0 ... +100.0 °C -5.0 ... +100.0 °C
Universal applicability at highest
TDS: 0 ... 2000 mg/l -- standards is made possible by
Temperature probe
Salinity: 0.0 ... 50.0 -- the use of stainless steel
electrodes (1.4404, 1.4435).
Resistivity: -- 0.0100 ... 0.2000 MΩ*cm
-- 0.010 ... 2.000 MΩ*cm
-- 0.01 ... 20.00 MΩ*cm
Accessories and spare parts:
Accuracy: (±1 digit, at nominal temperature = 25 °C)
GKL 100
Conductivity: ±0.5 % of m.v. ±0.5 % FS typ. ±1 % of m.v. ±0.5 % FS Product-ID: 601396
Temperature: ±0.3 °C ±0.3 °C Conductivity control solution
(100 ml bottles with 1413 µS/cm acc. to DIN EN 27888)
Temperature- off: deactivated off: deactivated
compensation: nLF: non-linear, acc. to EN 27888 nLF: non-linear, acc. to EN 27888 GKL 101
-- LIN: linear, with adjustable coeffi cients Product-ID: 601398
-- NaCl: compensation for weak NaCl- Conductivity control solution (250 ml bottles with 84 µS/cm)
solutions acc. to EN 60746-3 GKL 102
Reference temperatures: 20 and 25 °C 20 and 25 °C Product-ID: 601400
Conductivity control solution (100 ml bottles with 50 mS/cm)
Simulator
43
for additional accessories p.r.t. page 72 - 78
PH / REDOX / O2 dissolved
Handheld instrument
Display / Controller
GMH 5530
GMH 5550
GMH 3531
GMH 3551
GMH 5630
GMH 5650
GMH 3651
GMH 3511
GMH 3611
GPH 114
GOX 20
Application:
Waters measuring,
fish-keeping, aquafarming ● ● ● ● ● ● ● ● ● ● ●
Drinking water-, process mo-
nitoring, ground measurement ● ● ● ● ● ● ● ● ● ● ●
Food production and
● ● ● ● ● ●
Transmitter
-control
Precision measurement ● ● ● ● ● ● ●
Laboratory (GLP) ● ● ● ● ● ●
Quality management ● ● ● ● ● ● ●
Water-proof ● ● ● ●
Temperature probe
Connections Electrode
BNC- 7-pol. LTW or 6-pol. 6-pole Mini-DIN- permanenty
BNC-socket BNC-socket connected to
socket HEC / LTW socket
Temperature 2 banana-jack 2 banana-jack device
--
automatic and
automatic and manual
Temperature compensation manual manual automatic automatic manual
(Pt1000)
(Pt1000, NTC 10k)
Simulator
Min/Max, Hold, Min/Max,
Auto-Off, Min/Max, Hold, Min/Max, Hold,
General functions Min/Max, Hold, Auto-Off Auto-Off, calibration, Hold, Auto-Off,
adjustable calibration
GLP Auto-Off correction
intervals of salinity
Interface ● ● ● ● ● ● ● ●
Analog output ● ● ● ● ● ● ●
Alarm / Protection, Level
Calibration history ● ● ●
Data logger, alarm ● ● ● ●
Device information:
Catalogue page 46 46 45 45 45 47 51 51 52 52 51
44
further information on www.greisinger.de
Handheld instrument water analysis
Handheld instrument
ERSION
FOR AUTOMATIC CONV
ORP MODE ALLOWS
EM ELECTRODES
TO HYDROGEN SYST
ISO
MPENSATION
AL TEMPERATURE CO
STANDARD- AUTOMATIC OR MANU
FUNCTIONS: DETECTION
AUTOMATIC BUFFER
AUTO
OFF EL ECTRODE‘S QUALITY
RATING FUNCTION OF
BAT
Display / Controller
ADDITIONAL FUNCTIONS GMH 3551:
OF
SUCCESSOR
GPHR 1400
UT GPRT 1400 &
NEW: ANALOG OUTP
Logger / EASYBus
FOR ALL VARIANTS
Transmitter
pH / ORP / temperature measuring device with data GMH 3511: 2-point calibration with Greisinger buffer
Specifications:
capsules (GPH 4, 7, 10)
logger w/o accessories GMH 3531, GMH 3551: Either 1-, 2- of 3- point calibra- p.r.t. GHM 3511
Specifications: tion with Greisinger standard buffer, buffer according to Scope of supply: GMH 3511, pH electrode GE 114,
DIN19266 (A, C, D, F, G) or manual buffer selection. temperature probe GTF 55 B, buf-
Measuring ranges:
Calibration interval (not for GMH 3511): fer capsules 5 x GPH 4, 5 x GPH
Temperature: -5.0 ... +150.0 °C or 7, 2 plastic wide mouth bottles
The device asks for a recalibration after a
23.0 ... +302.0 °F GPF 100
selectable time period (1 - 365 days or inactive)
pH: 0.00 ... 14.00 pH GMH 3551: Calibration history additional
Redox (ORP): -1999 ... +2000 mV Accessories:
ORP measurement (Redox):
Based on hydrogen system: There are 2 choices: GKK 1105
-1792 ... +2207 mVH (DIN38404) „mV“: standard ORP or mV measurement Product-ID: 601050
Temperature probe
rH: 0.0 ... 70.0 rH (not GMH 3511) „mVH“: temp. compensated conversion to hydrogen appropriate case
system acc. to DIN38404 part 6, table 1
Accuracy (device): ±1 digit at nominal temperature = 25 °C
based on the standard ORP electrode (e.g.
Temperature: ±0.2 °C (at range -5 ... 100 °C) GE105 with Ag/AgCl system and 3 mol KCl)
pH: ±0.01 pH used.
Redox (ORP): ±0.1% FS (mV or mVH) rH measurement: (except GHM 3511):
Calculation of the rH value by means of a ORP me- Accessories and spare parts:
rH: ±0.1 rH (not GMH 3511)
asurement and by manually entering the pH-value.
Sensor connections: The pH-value may also be taken from a previous pH GMH 55 ES
measurement. Product-ID: 603066
Temperature: 2 x 4 mm Additional set: pH-electrode GE 100 BNC, temperature
banana socket for Pt1000, 2-wire Analog output: probe GTF 55 B (Pt1000), case GKK3500, GAK1400
˄
pH, Redox: BNC socket 0 ... 1 V, not changeable 0 ... 1 V = 0 ... 14 pH or -2000
... 2000 mV, connection via 3-pole jack socket Ø 3.5 mm, GTF 55 B
Display: two 4-digit LCD displays resolution 13 bit, accuracy 0.05 % at nominal temperature Product-ID: 602764
(12.4 and 7 mm high) GMH 3551: Analog output freely scalable Temperature probe, Pt1000 (see page 47)
Simulator
BAT
MIN
MAX ALARM LOGG
Logger / EASYBus
WATER-PROOF
NNECTIONS
DEVICE AND PLUG CO
46
further information on www.greisinger.de
Handheld instrument water analysis
Handheld instrument
Supplementary set
GMH 55 ES
ISO
Accessories and spare parts:
GMH 55 ES FUNCTIONS:
Product-ID: 603066
Supplementary set, including pH-electrode
(GE 100 BNC), temperature probe
BAT
(GTF 55 B), case (GKK 3500),
working and calibration set (GAK 1400)
Display / Controller
GE 125-BNC
Product-ID: 600732
waterproof pH-electrode with integrated Pt1000 temperature sensor GAK 1400
incl. waterproof BNC-plug and two banana plugs (p.r.t. page 48)
RECOMMENDED
GTF 55 B
Product-ID: 602764
Pt1000 temperature immersion sensor for liquids
1 m PVC-cable with two banana plugs1 m
GPH 114
Logger / EASYBus
Product-ID: 604700
pH-meter ready for use incl. pH-electrode type GE 114 and battery.
GE 100-BNC
Product-ID: 600704 Specifications:
pH-electrode (p.r.t. page 48) Measuring range: 0.00 ... 14.00 pH with standard pH-electrode type GE 114
Resolution: 0.01 pH
Accuracy (device): ± 0.02 pH ± 1 digit (at nominal temperature 25 °C)
GE 105-BNC Working conditions: 0 ... 45 °C; 0 ... 80 % RH (non condensing)
Product-ID: 600740 Storage temperature: -20 ... +70 °C
Redox-electrode (p.r.t. p. 49)
Connection: BNC Bajonett
pH-electrode: GE 114 (standard electrode)
Combination electrode with GEL-electrolyte. Measuring
range: 0-14 pH, temperature 0-60 °C, conductivity >200 μS/cm
Transmitter
PHL 4
Product-ID: 601370 Input resistance: approx.1012 Ohm
ready-to-use buffer solution (pH 4.01 / 25 °C), 250 ml Display: 3½-digit LCD display, 13 mm high
PHL 7 Calibration: 3 turning knobs for: 1. temperature compensation 0-90 °C,
Product-ID: 601371 2. pH 7 value and 3. pH X value (e.g. pH 1,09, pH 4, pH 10 or
ready-to-use buffer solution (pH 7.00 / 25 °C), 250 ml pH 12, depends on working range)
PHL 10 Power supply: 9 V battery
Product-ID: 601373
Battery service life: approx. 200 operating h
ready-to-use buffer solution (pH 10.01 / 25 °C), 250 ml
EMC: The device corresponds to the essential protection ratings
KCL 3 M
established in the Regulations of the Council for the Appro-
Product-ID: 602477
ximation of Legislation for the member countries regarding
Temperature probe
3 mol KCl electrolyte for refi ll or storage (fi lled in the protective cap) of electrodes with
electromagnetic compatibility (2004/108/EG)
3 mol KCl electrolyte. 100 ml plastic vial.
Additional fault: <1 %
CaCl
Housing: Impact resistant ABS
Product-ID: 603254
1000 ml, solution for measuring the pH value of soil Dimensions: 106 x 67 x 30 mm (H x W x D)
GRL 100 Weight: approx. 200 g (incl. battery and electrode)
Product-ID: 601422 Scope of supply: Device, pH-electrode GE 114, battery, manual
Pepsin cleaning solution, 100 ml
GRP 100 Accessories and spare parts:
Product-ID: 601424 GE 114-BNC
ORP buffer solution (220 mV at 25 °C), 100 ml Product-ID: 604701
Spare electrode
GAK 1400 GPH 114 GL
Product-ID: 603523 Product-ID: 600119
Working and calibration set Loose device (without accessories)
Simulator
GE 100-BNC
General: Product-ID: 600704
Working and calibration set consisting of: Universal electrode (0-14 pH, 0-80 °C)
5 buffer capsules each GPH4.0, GPH7.0 and GPH10.0,
GE 101-BNC
3 x 100 ml-plastic bottle GPF100, 1 x 3 mol KCL-
Product-ID: 600693
electrolyte KCL3M and 1 x Pepsin-cleaning agent
Injection electrode (2-11 pH, 0-60 °C)
GRL100. GAK1400 is required if no buffer solutions
are existing. GE 104-BNC
Product-ID: 602063
pH-electrode for low-ion water (as of 25 µS/cm)
Alarm / Protection, Level
GKK 252
Product-ID: 601056
Case (235 x 185 x 48 mm) with foam lining
GKK 1100
Product-ID: 601060
Case (340 x 275 x 83 mm) with foam lining
GB 9 V
Product-ID: 601115
Spare battery
additional accessories p.r.t. p. 49
47
for additional accessories p.r.t. page 72 - 78
PH ELECTRODES
Handheld instrument
STERILIZABLE
Display / Controller
GE 100 GE 101 GE 104 GE 108 GE 114 GE 117 GE 120 GE 125 GE 151 GE 171 GE 173
Measuring 0 ... 14 pH 2 - 11 pH 2 ... 14 pH 0 ... 14 pH 0 ... 14 pH 0 ... 14 pH 0 ... 14 pH 0 ... 14 pH 0 ... 14 pH 0 ... 14 pH 0 ... 14 pH
range 0 ... 80 °C 0 - 60 °C 0 - 80 °C 0 ... 80 °C 0 ... 60 °C 0 ... 80 °C 0 ... 60 °C 0 ... 70 °C -5 ... 80 °C 0 ... 140 °C 0 ... 80 °C
Logger / EASYBus
Conductivity > 100 µS / cm > 100 µS / cm > 20 µS / cm > 100 µS / cm > 200 µS / cm > 100 µS / cm > 200 µS / cm > 200 µS / cm > 100 µS / cm > 100 µS / cm > 50 µS / cm
Electrolyte 3 mol/l KCl 3 mol/l KCl 3 mol/l KCl gel electrolyte gel electrolyte gel electrolyte gel electrolyte gel electrolyte 3 mol/l KCl gel electrolyte gel electrolyte
Diaphragm 2 x ceramic 2 x ceramic moving joint 2 x ceramic 1 x pellon 2 x ceramic 2 x ceramic 1 x ceramic 1 x ceramic 2 x ceramic joint
Thread without without without PG 13.5 without PG 13.5 without without without PG 13.5 PG 13.5
Transmitter
Electrode Tyril, glass, Ø 12 or glass, PSU, epoxide, PSU, PVC, epoxide, glass, glass, glass,
shaft Ø 12 mm x 6 mm x 120 Ø 12 mm x Ø 12 mm x Ø 12 mm x Ø 12 mm x Ø 22 mm x Ø 12 mm x Ø 12 mm x Ø 12 mm x Ø 12 mm x
120 mm mm 120 mm 120 mm 120 mm 120 mm 110 mm 120 mm 120 mm 120 mm 120 mm
Features universal tip Ø 6 mm, for low-ion low- Low-cost temperature insertion submersible, chemicals- for extreme for process
electrode small sample media maintenance low- compensated electrode, water-proof resistant glass conditions, chemistry,
volume maintenance blade Ø 13 mm IP67 (also shaft sterilizable, bio-chemistry,
x 60 mm BNC-plug) autoclavable alkali-resistant
Connection:
BNC
600704 600693 602063 600713 604701 600730 600698 600732 600727 - 600735
Product-ID:
Temperature probe
Cinch
600702 600690 604504 600711 - - 600696 - 600724 - 600734
Product-ID:
S7*)
- - - 606089 - - - - - 606375 606572
Product-ID:
*)
Note: cable GEAK-2S7-BNC or GEAK-5S7-BNC is needed for connection S7, for devices with cinch connection adapter GAD 1 BNC is necessary.
Electrodes are consumption objects. Lifetime under careful treatment: > 2 years; warranty: 12 months
Handheld instrument
Accessories and spare parts:
GEAK-2S7-BNC
Product-ID: 601996
GR 105
GR 175
GE 100
GE 101
GE 104
GE 108
GE 120
GE 125
GE 151
GE 171
GE 173
GE 114
GE 117
Adapter cable S7-BNC, 2 m
GEAK-5S7-BNC
Application Product-ID: 601998
Adapterkabel S7-BNC, 5 m
Sewage ● VD120
Product-ID: 601380
Pricker for insertion electrode GE101
Aquarium water ● ● ● ● ● ● ● ●
GAD 1 BNC
Product-ID: 601382
Display / Controller
Soil testing ● Adapter to connect electrodes with Cinch plug to devices
with BNC socket.
GPF 100
Emulsions ● ● Product-ID: 601417
Plastic wide mouth bottle, 100 ml
On-site measurements ● ● ● ● ● GPH 4,0 / 5
Product-ID: 602614
Buffer capsules (5 pieces), pH 4.0
Fish farming ● ● ● ● ● ● ● ● ● GPH 4,0 / 10
Product-ID: 602615
Galvanic baths Buffer capsules (10 pieces), pH 4.0
● ●
GPH 7,0 / 5
Logger / EASYBus
Product-ID: 602616
Beverages ● ● ● ● ● Buffer capsules (5 pieces), pH 7.0
GPH 7,0 / 10
Low-ion media Product-ID: 602617
● ●
Buffer capsules (10 pieces), pH 7.0
GPH 10,0 / 5
Cosmetics ● Product-ID: 602618
Buffer capsules (5 pieces), pH 10.0
Food sample ● ● GPH 10,0 / 10
Product-ID: 602619
Buffer capsules (10 pieces), pH 10.0
Sea water ● ● ● ● ● ● ● ● ● ● ● ● ● GPH 12,0 / 5
Product-ID: 602620
Buffer capsules (5 pieces), pH 12.0
Online measuring ● ● ●
Transmitter
GPH 12,0 / 10
Product-ID: 602621
Process chemistry ● ● ● ● Buffer capsules (10 pieces), pH 12.0
All buffer capsules are traceable to NIST standards and
have ±0.02 pH at 25 °C.
Swimming pool water ● ● ● ● ● ● ● ●
GAK 1400
Product-ID: 603523
Suspensions ● ● ● Working and calibration set; GPH4.0, GPH7.0, GPH10.0 (5
capsules of each type); 3 x GPF100; 1 x KCL3M; 1 x GRL100
PHL 4
Drinking water ● ● ● ● ● ● ● ● ● Product-ID: 601370
Temperature probe
ready-to-use buffer solution (pH 4.01 / 25 °C), 250 ml
Water-based lacquers ● ● PHL 7
Product-ID: 601371
ready-to-use buffer solution (pH 7.00 / 25 °C), 250 ml
Note: The set information are to provide general recommendations. It needs to be checked, which electrodes for each
PHL 10
area of application are suitable.
Product-ID: 601373
ready-to-use buffer solution (pH 10,01 / 25 °C), 250 ml
ORP ELECTRODE KCL 3 M
Product-ID: 602477
3 mol KCl electrolyte for refi lling and storage (fi ll into
Specifications: GR 105 GR 175
protective cap) of electrodes with 3 mol KCl electrolyte,
Measuring unit: ORP injection bottle, 100 ml
1000 ml, solution for measuring the pH value of soil
with BNC connection Temperature no
measurement: GRL 100
GR 105-Cinch Water-proof: no
Product-ID: 601422
Pepsin cleaning solution, 100 ml
Product-ID: 607797 Pressure resistant: no 6 bar
with Cinch connection GRP 100
Cable: 1 m 1) without / 1 m Product-ID: 601424
Electrolyte: 3 mol/l KCL gel electrolyte ORP test solution (220 mV at 25 °C), 100 ml
NEW ! Diaphragm: 2 x ceramic 1 x ceramic GWA1Z
Product-ID: 602914
Metal electrode: Ø 5 mm Platin dome
Thread adapter PG13.5 to G1“, plastic
Alarm / Protection, Level
Thread: no PG 13,5
PG 13.5
Electrode shaft: Tyril, Ø 12 mm Glass, Ø 12 mm Product-ID: 603205
GR 175-BNC x 120 mm x 120 mm Plug-on thread adapter for pressure-less
use, for any electrode
Product-ID: 607801 Minimal depth of immersion: 15 mm
with BNC connection Scope of supply: ORP electrode, manual GWA 11 PG
Product-ID: 605379
GR 175-S7 Thread adapter from PG11 external thread to PG 13.5
internal thread incl. sealing and PG11 counter nut,
Product-ID: 607802
material: polyamide, fi ber glass reinforced,
incl. S7 connector - without connecting cable *) O-ring: NBR, temperature range: -10 ... +100 °C
49
for additional accessories p.r.t. page 72 - 78
WATERPROOF HANDHELD MEASURING DEVICE FOR MEASURING DISSOLVED OXYGEN IN WATER
Handheld instrument
HIGHLIGHTS
STANDARD-
• Waterproof and durable (protective silicone case)
FUNCTIONS:
• Large double display with background lighting
AUTO-
HOLD
NEW ! • New oxygen sensor GWO 5610
AUTO
OFF • Environmental pressure compensation with integrated barometer
predecessor model
• Compact 12 mm diameter
GMH 5630 Working temperature: Device: -25 ... +70 °C
retained!
Product-ID: 606880 Sensor: 0 ... 40 °C
NEW !
Waterproof dissolved O2 handheld measuring Sensor operating max. 3 bar corresponds to max.
device without accessories pressure: 30 m water depth
Inward flow: min. 20 cm / s
GMH 5650 Power supply: 2 x AAA battery,
Product-ID: 606882 power consumption: 0.9 mA
Waterproof dissolved O2 handheld measuring device
Transmitter
(integrated) (integrated) /
measuring Additional functions: Accessories and spare parts:
depth *1) Salinity correction: 0.0 ... 70.0 GWO 5610-L04
Measuring ranges: Pabs / height correction: Automatic with integrated Product-ID: 607764
O2-concentration: 0.00 ... 70.00 mg/l (ppm) sensor Spare sensor GWO 5610 with 4 m cable (fi eld use)
(Variable resolution) Measuring depth (only GMH 5650): Hydrostatic depth GWO 5610-L10
measurement *1) Product-ID: 607765
O2-saturation: 0.0 ... 600.0 % O2
(Variable resolution) Output / external supply: Spare sensor GWO 5610 with 10 m cable (fi eld use)
OUT jack: 38400 baud interface, 5 V external supply GWO 5610-L30
O2-partial pressure: 0 ... 1200 hPa O2 Additional with GMH 5650: Analogue output 0-1 V,
(0.0 ... 427.5 mmHg) Product-ID: 607766
adjustable Spare sensor GWO 5610 with 30 m cable (fi eld use)
Temperature: 0.0 ... 50.0 °C Calibration: 1 point air
GSKA 3600
Air pressure: 10 ... 1200 hPa 300 ... 5000 hPa Additional with GMH 5650: 1 point water, 2 point or
Product-ID: 601414
abs abs 3 point (air and zero point and 100 % O2)
Protective PVC cap
Simulator
50
further information on www.greisinger.de
Handheld instrument water analysis
Handheld instrument
FUNCTIONS:
BAT
NEW ! READY-TO-USE
Display / Controller
Logger / EASYBus
GMH 5630-L02 GOX 20
Product-ID: 607470 Product-ID: 600126
Waterproof dissolved O2 handheld measuring device, Oxygen measuring device, operative, incl. oxygen probe and battery
including sensor GWO 5610, 2 m cable Specifications:
GMH 5650-L02 Measuring range:
Transmitter
Product-ID: 607474 Temperature: 0.0 ... 40.0 °C
Waterproof dissolved O2 handheld measuring device, including sensor Oxygen: 0.0 ... 20.0 mg/l O2
GWO 5610, 2 m cable, with data logger and alarm Resolution:
Versions: Temperature: 0.1 °C
GMH 5630-L04 Oxygen: 0.1 mg/l O2
Product-ID: 606881
Accuracy: (at nominal temperature = 25 °C) ±1 digit
GMBH 5630 handheld measuring device with sensor with 4 m cable length
Temperature: ±0.3 °C (in range 0-30 °C)
GMH 5630-L10
Product-ID: 607471 Oxygen: ±2 % o. m.w. ±0.2 mg/l
GMBH 5630 handheld measuring device with sensor with 10 m cable length Electrode: active diaphragm type. Electrode-Ø front: approx. 12 mm,
Temperature probe
GMH 5630-L30 length: approx. 170 mm, connecting cable approx. 2 m
Product-ID: 607472 permanently connected to device.
GMBH 5630 handheld measuring device with sensor with 30 m cable length Response time: 95 % in 10 s, depending on temperature.
GMH 5650-L04 Operation life: approx. 3 years or more depending on maintenance
Product-ID: 606883
Operation pressure: max. 3 bar
GMBH 5650 handheld measuring device with sensor with 4 m cable length
Temperature automatically via temperature sensor integrated in electrode
GMH 5650-L10
compensation:
Product-ID: 607478
GMBH 5650 handheld measuring device with sensor with 10 m cable length Calibration: simple quick-calibration in atmospheric air
GMH 5650-L30 Display: 3½-digit LCD display, 13 mm high
Product-ID: 607479 Working temperature: 0 ... 50 °C
GMBH 5650 handheld measuring device with sensor
Power supply: 9 V battery
with 30 m cable length
Power consumption: max. 1 mA
Simulator
KOH 100
Product-ID: 603356
spare electrolyte 100 ml
51
for additional accessories p.r.t. page 72 - 78
OXYGEN MEASURING DEVICES FOR DISSOLVED OXYGEN IN LIQUIDS
Handheld instrument
STANDARD- HIGHLIGHTS:
FUNCTIONS:
• Automatic air pressure compensation
AUTO
OFF • Salinity correction
ENTRATION
MEAS. UNITS: O2-CONC
O2-SATURATION
SURE (GMH3651 ONLY)
AND O2-PARTIAL PRES
Logger / EASYBus
Handheld Measuring device..... with Sensor with ... m cable
length
Specifications: Device GMH 3651 with Sensor with 10 m cable length
Housing 142 x 71 x 26 mm (H x W x D) GMH 3651-L30
Measuring ranges: (device)
dimensions: impact-resistant ABS, front side Product-ID: 606106
O2-concentration: 0.00 ... 70.00 mg/l (ppm) IP65, integrated pop-up clip for
(resolution selectable) Device GMH 3651 with Sensor with 30 m cable length
table top or suspended use.
O2-saturation: 0.0 ... 600.0 % O2 Weight: approx. 300 g Accessories and spare parts:
(resolution selectable) (incl. battery and probe) GMH 3611-GL
O2-partial pressure: 3651: 0 ... 1200 hPa O2 Scope of supply: Device incl. electrode, GWOK01 Product-ID: 606310
(0.0 ... 427.5 mmHg) and KOH electrolyte. Oxygen measuring device without accessories
Temperature: 0.0 ... 50.0 °C GMH 3651-GL
Additional functions: Product-ID: 606312
Pressure: 3611: 10 ... 1200 hPa abs.
Temperature compensation:
Temperature probe
3651: 10 ... 11000 hPa abs. or Oxygen measuring device without accessories
0 ... 100.0 m water column* automatic via temperature sensor integrated in electrode. GWO 3600-L04
(with pressure port) Air pressure compensation: Product-ID: 603895
Accuracy: (at nominal temperature = 25 °C) automatic via integrated pressure sensor. Display of Spare sensor with 4 m cable
Oxygen: ±1.5 % of m.v. ±0.2 mg/l current air pressure. GWO 3600-L10
(0 ... 25 mg/l) or ±2.5 % of m.v. Correction of salinity: Product-ID: 603258
±0.3 mg/l (25 ... 70 mg/l) autom. salinity value can be set via keyboard from Spare sensor with 10 m cable
Temperature: ± 0.1 °C ± 1 digit 0.0 ... 70.0 GWO 3600-L30
Product-ID: 603259
Pressure: ± 0.5 % FS ± 1 digit Calibration:
Spare sensor with 30 m cable
±3 hPa or 0.1 % of m.v. 1-point calibration: extremely simple quick
±2 hPa (750 ... 1100 hPa) calibration in atmospheric air. GWOK 01
additional at GMH 3651: 2- and 3-point-calibration Product-ID: 601411
Sensor connection: 6-pin screened Mini-DIN-socket
spare diaphragm head
Sensor: Active membrane type. Electrode- Calibration interval:
The device asks for a recalibration after a selectable time GAS 3600
Ø front: approx. 12 mm, overall
Product-ID: 603497
Simulator
length: approx. 220 mm, anti period (1 - 365 days or inactive).
GMH 3651: additional calibration history Working set (consisting of 3 spare diaphragm heads
buckling glanding, neck collar: Ø
and 100 ml KOH-electrolyte)
approx. 20 mm, 4 m connection Analog output (GMH 3651 only):
cable with Mini-DIN-plug GSKA 3600
0 -1 V, freely adjustable
Product-ID: 601414
Response time: 95 % in 10 s, depends on
Alarm (GMH 3651 only): PVC protection cap
temperature
2 Alarm (O2 and temperature) with separate alarm limits, GSKA 3610
Operation life: approx. 3 years, depends on Alarm horn / visual / interface Product-ID: 607267
maintenance
Data logger (GMH 3651 only): Protection cap for depth measurement
NEW !
Working 0 ... +40 °C cyclic: 10.000 data sets, manual: 1.000 data sets brass with hole for an attachment
temperature: to carabiners / rope
Alarm / Protection, Level
(with measuring point input, 40 adjustable measuring
Working pressure: max. 3 bar point texts or measuring point numbers) KOH 100
Operating pressure sensor GWO Product-ID: 603356
3600 max. 3000 hPa rel. or 4000 * There is the possibility for hydrostatic depth measure-
ments with special accessories (upon request / pressure Spare electrolyte 100 ml
hPa pay attention to abs.!
connection). This allows in combination with the logger
Flow rate: min. 30 cm/s function e.g. comfortable recordings of oxygen profiles
Display: 2 x 4 digit LCDs in waters.
(12.4 / 7 mm high)
52
further information on www.greisinger.de
Handheld instrument Gas
GAS
Handheld instrument
Display / Controller
Logger / EASYBus
GMH 5690
GMH 5695
GMH 3692
GMH 3695
GOX 100T
GCO 100
GOX 100
+Sensor
+Sensor
Application:
Transmitter
Measurement of
atmospheric oxygen ● ● ● ● ● ●
O2-concentration ● ● ● ● ●
O2-partial pressure ● ● ● ●
CO-concentration
(carbon monoxide) ●
Temperature probe
Protective gases ● ● ● ●
Diving * ● ● ● ●
Exhaust gas monitoring ●
Equipment:
Measuring ranges O2-concentration 0 ... 100 % O2-concentration 0 ... 100 % CO-concentration
O2-partial pressure 0 ... 1100 hPa O2-partial pressure 0 ... 1100 hPa 0 ... 1000 ppm
O2-concentration 0 ... 100 %
Temperature -5 ... +50 °C Temperature -5 ... +50 °C 0 ... 1250 mg/m3
ambient pressure 10 ... 1200 hPa 0 ... 11000 hPa 10 ... 1200 hPa 0 ... 11000 hPa 0 ... 60 % COHb
external sensor, order sensor external sensor, order sensor
Simulator
Min/Max, Hold,
Min/Max, Hold, Auto-Off, Min- / Max, Max, Hold,
General functions Min/Max, Hold, Auto-Off Auto-Off,
background illumination Hold, Auto-Off Auto-Off
MOD-Anzeige
Alarm / Interface ● ● ● ● ●
Alarm / Protection, Level
Logger ● ●
Device information:
Catalogue page 54 54 55 55 58 58 58
* not suited for „under water“-applications (rebreather, etc.)
53
for additional accessories p.r.t. page 72 - 78
WATERPROOF HANDHELD MEASURING DEVICE FOR MEASURING OXYGEN IN AIR AND GASES
Handheld instrument
NEW ! HIGHLIGHTS
ISO
• High display resolution (0.01 % O2 concentration)
STANDARD-
• Waterproof and durable (protective silicone case)
FUNCTIONS:
• Large double display with background lighting
ALARM
• Multi-point calibration for precision measurements
AUTO-
Display / Controller
LOGG
GMH 5695
Product-ID: 607468
Transmitter
Waterproof air oxygen measuring device without sensor with data logger and
alarm
Application: Ingress protection: IP65 / IP67
Protective gas measurements for Housing: Impact-resistant ABS, with stand/hanging bracket
- Welding and soldering Dimensions: 160 x 86 x 37 mm (H x W x D) including protective silicone case
- Food production/packaging technology (MAP, see also the GHM 5690 GOG Set)
- For storage of foods, semiconductor components, etc. Weight: approx. 250 g, including battery and protective case
- Immersion gas testing: Checking of oxygen concentration in nitrox, trimix or similar gas Scope of supply: Handheld measuring device incl. batteries (2xAAA), protective
compositions silicone case, manual, quick guide
Note: Not suitable for use in 'underwater applications' (rebreather, etc.)
*) Optimal air pressure compensation with GGA 570 /GGA 580
Temperature probe
See page 56/57 for matching sensors
Temperature: ±0.1 °C ± 1 digit
GKK 3600
Air pressure: ±3 hPa or 0.1 % of MW (higher applies) Product-ID: 601062
Compatible sensors GGO5 / GOO5 with elements GGA5 / GGO5 / GOO5 with with napped foam for universal application (394 x 294 x 106 mm)
GOEL 370, 380 etc. elements GOEL 370, 380 etc. USB 5100
Connections: Product-ID: 601095
Sensor: 7-pin bayonet connection 7-pin bayonet connection Interface converter GMH 5xxx <=> PC
Port for pressure connection*) GSOFT 3050
Output / OUT jack: OUT jack: Product-ID: 601336
Windows software for GMBH 3000 and GMH 5000 handheld measuring devices with
Alarm / Protection, Level
54
further information on www.greisinger.de
Handheld instrument Gas
Handheld instrument
ISO
HIGHLIGHTS:
STANDARD-
FUNCTIONS: • Alarm detector with integrated horn
AUTO
Display / Controller
OFF
ADDITIONAL FUNCTIONS GMH 3695:
BAT
ALARM LOGG
HOLD
MIN
MAX
Logger / EASYBus
REPLACEMENT FOR A MONITORING DEVICE SUBJECT
ICATION FOR
WIDE RANGE OF APPL TO AUTHORISATION!
YOUR HO ME, JOB AND HOBBY!
Transmitter
Weight: approx. 160 g (incl. battery)
- Bio chemistry: Scope of supply: Device, battery, manual
Oxygen monitoring in breeding chambers for cell cultures. Monitoring of fermenting
process of fruits in fermentation plants etc. Additional functions:
- Medicine: Temperature compensation: automatic via temperature sensor, integrated in probe
Monitoring of oxygen concentration in respirators; checking of breathing, monitoring of housing.
oxygen concentration in incubators, oxygen tents etc. Air pressure compensation: The O2 concentration will be compensated according to the
- Food technology: absolute atmospheric pressure set.
Monitoring of residual oxygen in packages (e.g. coffee, tea, etc.). Calibration:
Monitoring of oxygen content during production processes. 1-point calibration: extremely simple quick calibration in atmospheric air.
- Air conditioning and ventilation technology: (press button to compensate unit to 20.9 %).
Oxygen measurements, air quality monitoring, measuring of oxygen concentration in 2-/3-point calibration: fi rst point at atmospheric air (20.9 %), second and third point 0 or
Temperature probe
enclosed air conditioning systems, etc. 100 %.
- Sport: Calibration interval:
Checking of oxygen content in compressed air bottles (diving, etc.). The device asks for a recalibration after a selectable time period (1 - 365 days or inactive).
Note: not suited for „under water“-applications (rebreather, etc.) GMH 3695: additional calibration history
Specifications: Analog output (GMH 3695 only): 0 - 1 V, freely scalable
Measuring ranges: Pressure nozzles for pressure compensation
Oxygen concentration: 0.0 ... 100.0 % O2 (gaseous) Data logger (GMH 3695 only):
0 ... 1100 hPa O2 cyclic: 8000 data sets, adjustable cycle time: 1 s … 60 min
manual: 1000 data sets, with measuring point input
Temperature: -5.0 ... +50.0 °C
Air pressure: GMH 3692: 10 ... 1200 hPa Accessories and spare parts:
GMH 3695: 10 ... 11000 hPa Suitable sensores p.r.t. next page
Accuracy: (device) (at nominal temperature = 25 °C) GKK 3000
Oxygen concentration: ±0.1 % ± 1 digit Product-ID: 601048
Simulator
calibration etc. Software for operation of logger devices
Working temperature: 0 ... +50 °C ST-R1
Relative humidity: 0 ... +95 % RH (non-condensing) Product-ID: 601066
device protection bag with cut-out for probe connection
Storage temperature: -20 ... +70 °C
Interface: serial interface, direct connection to RS232 or USB interface
of a PC via electrically isolated interface converter GRS 3100
or GRS 3105 resp. USB 3100 N (p.r.t. accessories).
55
for additional accessories p.r.t. page 72 - 78
ATMOSPHERIC OXYGEN SENSORES FOR GMH 569X AND GMH 369X
Handheld instrument
CLOSED SENSOR TYPE GGO CLOSED SENSOR TYPE WITH PRESSURE CONNECTION GGA
NEW !
Product-ID: 607484
Product-ID: 601224 Pressure connection, suitable for GMH 369x
Universal applications, diving, longlife, suitable for GMH 369x General:
General: For devices with external pressure port (GMH 5695/3695) is this housing optimal.
• suitable for under and over pressure Especially for systems with high or low pressure or with existing back pressure by fl ow.
• for using in gas-tight systems
Application:
Application: It can be screwed airtight (Attention: Observe permissible operating pressure!). The
Suitable for measuring in normal atmosphere and in systems without or with slight under device-pressure port is connected to the sensor pressure port. The device measures and
or over pressure. The sensor type features a screw thread and can be built in gas-tight in compensates for the actual pressure at the sensor.
almost every system directly resp. with tube-adapter.
longer cable length 4 m and 10 m on demand
longer cable length 4 m and 10 m on demand
Transmitter
housing replaceable (temperature sensor mounted in housing)
GOO 370 Connection: GGA/GGO/GOO 3...:
Product-ID: 601228 approx. 1.2 m cable with Mini-DIN-plug.
universal applications, diving, longlife, suitable for GMH 369x GGA/GGO/GOO 5...:
approx. 1 m cable with 7-pole bayonet connector
General: Dimensions of housing: GGA..: approx. Ø 36 mm x 95 mm
• suitable for air- or gas-stream (150 mm incl. anti-buckl. glanding),
• quick temperature compensation GGO..: approx. Ø 36 mm x 95 mm
(150 mm incl. anti-buckl. glanding),
Application: GOO..: approx. Ø 40 mm x 105 mm
Alarm / Protection, Level
Because of the special sensor construction the measuring gas streams optimally around (160 mm incl. anti-buckl. glanding)
the sensor and escapes through holes in the housing into the air. No pressure build-up at Housing with M16 x 1-screw thread (sensor can be connected
slight streaming of the probe, that falsify the result of measurement. Particularly suitable to line tubes by means of an additional adapter)
for measuring of gas out of gas-bottle etc. Even measuring indoor-gas concentration is Weight: approx. 135 g (GGO...) or approx. 145 g (GOO.../GGA...)
possible.
Scope of supply: GGA.../GGO... : sensor, fl ow diverter, T-piece
GOO... : sensor, fl ow diverter
longer cable length 4 m and 10 m on demand
56
further information on www.greisinger.de
Handheld instrument Gas
Handheld instrument
GOEL 370
Product-ID: 601490
sensor element (acidic electrolyte):
General:
Display / Controller
Integrated into GGO 370, GGA 370, GOO 370 (for GMH
3690 / 91 / 92 / 95) or GGO 570, GGA 570, GOO 570 (for
GMH 5690 / 95)
Universal sensor element with special precautionsparti-
cularly for immersion applications ("nitrox"),very long life,
even for applications withelevated CO2 concentration. GMH 5690
Note:
not suited for „under water“-applications (rebreather, etc.)
APPLICATION IN
INDUSTRY
PA CKAGING AND FOOD
Logger / EASYBus
GOEL 380 GMH 3692 GOG-H Scope of supply: Device GMH3692, hand pump
Product-ID: 601492 Product-ID: 605925 with air tube, GOG oxygen sensor
sensor element (alkaline electrolyte) Residual oxygen measuring device for universal use with penetration needle, case
GKK 3500, spare needle Ø 0.9
General: GMH 3692 GOG-L mm, rubber foam sticker (40
pieces), battery, operating manual.
ntegrated into GGO 380, GGA 380, GOO 380 (for GMH Product-ID: 605926
3690 / 91 / 92 / 95) or GGO 580, GGA 580, GOO 580 (for Residual oxygen measuring device for low for additional technical data refer to GMH3692 and
GMH 5690 / 95) Fast sensor element especially for low corresponding sensors on page 56
Oxygen concentrations below 1 %, measuring range up to
oxigen-concentrations with fast response time
25 %, e. g. a protective gas atmosphere. For application
GMH 5690 GOG-H Accessories and spare parts:
Transmitter
without permanently higher CO2 concentration GOG-SET-3000-H
Product-ID: 607746
Product-ID: 603048
Note: Residual oxygen measuring device for universal use Set without instrument
not suited for „under water“-applications (rebreather, etc.)
GMH 5690 GOG-L Scope of supply: GOG oxygen sensor (GOEL 370) with
penetration needle, hand pump with air tube, case GKK
Product-ID: 607748 3500, spare needle and 40 rubber foam stickers
Residual oxygen measuring device for low GOG-SET-3000-L
Accessories and spare parts: oxigen-concentrations with fast response time Product-ID: 603050
GZ-11 Application: Set without instrument
Product-ID: 603144 Scope of supply: GOG oxygen sensor (GOEL 380) with
If delicate products are conserved at low-oxygen atmo- penetration needle, hand pump with air tube, case GKK
fl ow rate adapter to measure
Temperature probe
spheres (protective gas), these measuring devices will 3500, spare needle and 40 rubber foam stickers
the oxygen concentration with 6/4 mm tube
provide a vital check of the residual oxygen content.
ESA 369 • packaging industry GOG-SET-5000-H
Product-ID: 603058 • food industry Product-ID: 607949
spare tube-adapter M16x1, for tubes Set without instrument
with a inner-diameter of 15 mm Specifications: Scope of supply: GOG oxygen sensor (GOEL 370) with
penetration needle, hand pump with air tube, case GKK
ZOT 369 Sensor elements: - H: GOEL 370 - L: GOEL 380 3500, spare needle and 40 rubber foam stickers
Product-ID: 603094
Measuring range - H: 0 ... 1100 - L: 0 ... 300 GOG-SET-5000-L
T-piece
(hPa O2): Product-ID: 607950
Measuring range - H: 0.0 ... 100.0 - L: 0.0 ... 25.0 Set without instrument
(% O2): Scope of supply: GOG oxygen sensor (GOEL 380) with
Response time: T90 - H: <10 s - L: <5 s penetration needle, hand pump with air tube, case GKK
3500, spare needle and 40 rubber foam stickers
Resolution: GMH 3692...: 0.1 % O2
GMH 5690...: 0.01 % O2 GOEL 370
Product-ID: 601490
Simulator
Accuracy: Spare sensor element, universal applications, diving,
(whole system - if careful calibration and measuring) longlife
1-point-calibration: ±0.2 % O2 ±1 digit GOEL 380
(for concentrations < 10 %) Product-ID: 601492
2-point-calibration: ±0.1 % O2 ±1 digit Spare sensor element, for low oxigen-concentration, fast
(for concentrations < 10 %) response time
Oxygen sensor: Oxygen partial pressure sensor, GOG-N
built in external sensor housing Product-ID: 603047
Operation life: 12 month warranty for sensor Needle, Ø 0.9 mm (5 pieces)
element (if appropriate application GOG-A
Alarm / Protection, Level
57
for additional accessories p.r.t. page 72 - 78
COMPACT AIR OXYGEN
COMPACT CO - MEASURING DEVICE MEASURING DEVICE
Handheld instrument
FUNCTIONS: HIGHLIGHTS:
ISO
AUTO
• 3 display units selectable
OFF (ppm, mg/m³ and % CO Hb) FUNCTIONS:
MIN
MAX
0 ... 1250 mg/m³ CO concentration
0 ... 60.0 % CO Hb GAS 100 Sensor Connection: 0.7 m jack-connector cable
(estimation via exhaled breath gas) Product-ID: 603587
extension set for exhaled air control (consisting of Sensor Oxygen-partial pressure probe,
Resolution: 1 ppm, 1 mg/m³ or 0.1 % CO Hb mounted in external sensor
ESA100, ZOT369, GRV 100 and 5x MSK100)
Measuring element: integrated in device, measuring in- housing
GZ-10
let at front plate, with inner thread Warranty: 12 months
Product-ID: 603133
for accessories screw in
test gas cap GCO (for controlled fl ow with test gas) Working pressure: 0.5 ... 2.0 bar abs.
Life time: >5 years at proper usage at air
GZ-02 Over- /under- max. 0.25 bar
suggested test interval: every 6
Product-ID: 603569 pressure: (pressure difference)
months (depending on precision
gas bottle with 12l test gas: 30 ppm CO Working 0 ... 45 °C (sensor),
requirements)
GZ-03 temperature: -20 ... +50 °C (device)
Accuracy: (at range 0 ... 500 ppm)
Product-ID: 603123 Relative humidity: 0 ... 95 % RH
linearity: < ±5 % of measured value ±1 digit gas bottle with 12l test gas: 300 ppm CO
Power supply: 9 V battery
repeatability: < ±5 % of measured value ±1 digit GZ-04
Simulator
Variants:
Pushbuttons: 3 membrane keys case (275 x 229 x 83 mm) with punched lining
GOX 100-LACK
Nominal temperature: 25 °C USB 3100 N Product-ID: 602047
Product-ID: 601092 with encapsulated PC board
Ambient condition: -10 ... +50 °C, 15 ... 90 % RH interface converter to USB, electrical isolated
(non condensing) (for applications where condensation is possible)
GAM 3000 GOX 100-T-LACK
Storage temperature: -10 ... +50 °C Product-ID: 601132 Product-ID: 604660
Serial interface: Serial interface, direct connection to switching module for 230 VAC/10 A with encapsulated PC board
RS232 or USB interface of a PC via
(for applications where condensation is possible)
electrically isolated interface adapter
58
further information on www.greisinger.de
Handheld instrument Pressure
PRESSURE
Handheld instrument
Display / Controller
Logger / EASYBus
GMH 3181--002 /
GMH 3161-002 /
-01 / -07... / -13
GDUSB 1000
GDH 200-07
GDH 200-13
GDH 200-14
GMH 5130
GMH 5150
GMH 5155
GMH 3151
GMH 3156
GMH 3111
GPB 3300
GTD 1100
Transmitter
Application:
Relative pressure meas.
(over, under- and pressure ● ● ● ● ● ● ● ● ● ● ●
difference)
Absolute pressure
measuring ● ● ● ● ● ● ● ● ● ● ● ●
Heating, ventilation,
climate ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Temperature probe
Measuring in liquids ● ● ● ● ● ● ●
Vacuum measuring ● ● ● ● ● ● ● ● ● ●
Meteorology ● ● ●
Altitude measuring (sports) ●
Water-proof application ● ● ●
Optionally EX-protection ● ● ● ● ● ● ●
Simulator
Equipment:
Device information:
59
for additional accessories p.r.t. page 72 - 78
WATER-PROOF HANDHELD DEVICE FOR PRESSURE MEASUREMENT WITH EXTERNAL CHANGEABLE PROBES
Handheld instrument
HIGHLIGHTS:
BAT
O / S-
CORR ADDITIONAL FUNCTIONS GMH 5150 AND 5155:
General: Connections:
This handheld instrument is a valuable tool for demanding pressure measurements. Sensor 1 x 7-pole bayonet connector
Extremely robust plug connections, the silicone protection cover, backlight and a water- GMH 5155 only: 2 x 7-pole bayonet connector
proof design allow its usage in harsh industrial and fi eld environments. Output / 4-pole bayonet connector for serial interface,
external supply * supply (with accessories: USB adapter USB 5100)
Application:
Analog output: 0 - 1 V, freely adjustable, connection with 4-pole bayonet
• industry and craft connector, resolution 12 bit
• HVAC: heating, ventilation, air-conditioning
• leakage test / pressure test Display: 4 ½ digit 7-segment, illuminated (white)
• chimney draft measurement: under pressure Working temperature: -25 ... +50 °C, 0 ... 95 % RH (non-condensing)
• leakage test at buildings (i.e. 4 Pascal test) Storage temperature: -25 ... +70 °C
Temperature probe
• measurements of gas and oil fi rings
• automobile trade Power supply: 2 x AAA-battery (included), battery life 500 h
• hydraulic analysis (peak pressure) (without illumination, 4 measurings / s)
Housing: impact resistant ABS housing with pop-up clip
Specifications: GMH 5130 Protection class: IP65 / IP67
Sensor connections: 1 Dimensions: 160 x 86 x 37 mm (H x W x D) incl. silicone protection
Suitable probes: GMSD / MSD sensors, available ranges (resolutions) from cover (red)
-1.999 … 2.500 mbar (0.001 mbar) to 0 … 1000 bar (1 bar) Weight: approx. 250 g incl. battery and protection cover
display range max.: -19999 ... +19999 digit Scope of supply: Device, battery, manual
Display unit: * depends on measuring range selection and sensor:
mbar, bar, Pa, kPa, MPa, mmHg, inHg, PSI, mH2O Additional functions:
Measuring frequency: 4 measurements / s or 1000 measurements / s with peak Additional Display for Battery: Bar graph display
value memory Background Illumination: duration adjustable (off, 5 s ... 2 min.)
Average filter: adjustable: 1 ... 120 s
Simulator
Adjustment: offset / slope adjustable in menu
Accuracy: ± 0.1 % FS ± 1 digit User-defined displayed unit: (user/GMH 5150/55)
Connections: conversion to any unit with help of linear factor
Sensor 1x 7-pole bayonet connector Leakage test function (GMH 5150/55):
Output / 4-pole bayonet connector for serial interface,* supply (with leak rate display, leak rate alarm (/s, /min, /h)
external supply accessories: USB adapter USB 5100) Air velocity / flow volume (GMH 5150/55):
Display: 4 ½ digit 7-segment, illuminated (white) Pitot tube measurement (accessories)
Working temperature: -25 ... +50 °C, 0 ... 95 % RH (non-condensing) peak-detect (Peak value memory):
The min- / max- value memory stored unfi ltered pressure peaks ≥1 ms
Storage temperature: -25 ... +70 °C
Alarm / Protection, Level
Logger function
Power supply: 2 x AAA-battery, battery life 500 h - cyclic: 10.000 data sets (GMH 5150), 8.000 data sets (GMH 5155)
(without illumination, 4 measurings / s) - manual: 1.000 data sets (with measuring point input, 40 adjustable measuring point texts
Housing: impact resistant ABS housing with pop-up clip or measuring point numbers)
Protection class: IP65 / IP67
Dimensions: 160 x 86 x 37 mm (H x W x D) incl. silicone protection
cover (red)
Weight: approx. 250 g incl. battery and protection cover
* = Note to the pressure unit selection:
Scope of supply: Device, battery, manual The choice of a specific pressure unit is possible, if its whole measuring range is display-
able within the display of the device and the sensor is supporting these resolution.
60
further information on www.greisinger.de
Handheld instrument Pressure
Handheld instrument
Accessories and spare parts:
GMSD ... - K51
pressure sensors
(p.r.t. page 62)
Application fi eld:
ISO HIGHLIGHTS:
non-aggressive gases
for over / under pressure and difference pressure meas. or FUNCTIONS: • one device for any measuring range
absolute pressure meas. (2.500 mbar ... 1000 bar)
AUTO
MSD ...
pressure sensors / stainless steel
OFF
(p.r.t. page 63)
Application fi eld: air, BAT
Display / Controller
aggressive gases
for over / under pressure and relative pressure meas. or LLY
absolute pressure meas. HOLD CALIBRATED AND FU
MSD-K51 INTERCHANGEABLE
Product-ID: 603809 MIN
1 m connection cable for MSD sensors
MAX PRESSURE PROBES
Prandtl-Staurohr O / S-
Product-ID: 604150 CORR
(made of stainless steel)
for air velocity / fl ow volume measurement
Ø = 3 mm, NL = 300 mm, max. 600 °C
TARA
GMSD 2,5 MR-K51 or GMSD 25 MR-K51 are required
GMH 3111 Suitable pressure probes
Art.-Nr 600374
Logger / EASYBus
p.r.t.p. 63 / 64
device with 1 sensor connection, without sensor
GMH 3111 - ex
Art.-Nr 600380
device with 1 sensor connection, without sensor, ex
Specifications: Note to Ex- design types:
GDZ-01 max. display range: -19999 ... +19999 digit Technical changes compared to standard
Product-ID: 601541 instrument (valid for all GMH31xx - ex)
PVC tube 6/4 (6 mm outer Ø, 4 mm inner Ø) Measuring range: corresponding to used probe
(5 bar at 23 °C) Overload: corresponding to used probe Ex qualification:: II 2 G Ex ib IIC T4 Gb
Resolution: corresponding to used probe Ref. document: EPS 09 ATEX 1 227 X
Accuracy: (device) ±0.1 % FS ±1 digit (at nominal
temperature = 25 °C) Standards:
Transmitter
GDZ-30 The device meets the standards for electric resources in
Product-ID: 601601 Pressure units: * mbar, bar, Pa, kPa, MPa, mmHg,
explosion
Adapter G1/2“ inner to tube 6/4 PSI, mH2O,
endangered areas according to EN 60079-0 : 2012, EN
can be selected.
EBS 20M 60079-11 : 2012
Product-ID: 601158 Probe connection: 1 sensor socket
6-pin lockable Mini-DIN-socket(s) Probe:
software for long-term monitoring (p.r.t. page 77)
for GMSD/MSD-sensors. (GMH 3111 - ex, GMH 3151 - ex, GMH 3156 - ex) All
GSOFT 3050 Automatic probe detection and GMSD sensors with option ‚Ex type‘ can be used.
Product-ID: 601336 setting of measuring range upon
Software for operation of logger devices (p.r.t. page 77) Interface:
plugging in of probe.
suitable interface adapter are USB 3100 N,
USB 5100 Display: 2 x 4½ digit LCD GRS 3100 and GRS 3105
Product-ID: 601095
Output: interface Please note: The operation of the interface is not allowed
Temperature probe
Electrically isolated interface converter, supplied via USB
within the Ex area!
GNG 5 / 5000 serial interface: direct connection to RS232 or
Product-ID: 602287 USB interface of a PC via electri- Working temperature: -10 ... +50 °C
Plug-in power supply 5 V DC, suitable for GMH 5000 cally isolated interface converter
series (see p. 75) GRS 3100, GRS 3105 or USB Power supply: 9 V-battery, d.c. connector
3100 N. Please note:
GKK 3500 the use of d.c. connector is not allowed within the Ex
Product-ID: 601052 Power supply: 9 V-battery, d.c. connector for
area!
Device case (394 x 294 x 106 mm) with eggcrate foam external 10.5-12 V direct voltage
Just d.c. connectors of type GNG10/3000 can be used.
and cut-outs for 1 device (p.r.t. page 72) supply. (suitable power supply:
GNG10/3000) Alarm function:
Sensor adjustment: digital offset and scale input (GMH 3151 - ex, GMH 3156 - ex, GMH 3181 - ex)
Measuring cycle: 4 measurements / s The device is without a horn, in the alarm settings are
only the parameter „no.so“ and „off“ adjustable.
Power consumption: approx. 1.6 mA
Working condition: -25 ... 50 °C, 0 ... 95 % RH, Scope of supply:
device with associated leather case.
Simulator
GMH 3111-ex: -10 ... +50 °C,
0 ... 95 % RH
Housing: impact-resistant ABS plastic
housing, Front side IP65
GMH 3111 only: integrated pop-
up clip for table top or suspended
use.
Dimensions: 142 x 71 x 26 mm
Weight: approx. 150 g, GMH3111-ex:
approx. 190 g (incl. leather case)
Alarm / Protection, Level
61
for additional accessories p.r.t. page 72 - 78
TUBE, TUBE CLIPS, ADAPTER,
PRESSURE MEASURING DEVICE WITH LOGGER COUPLINGS, ETC.
Handheld instrument
01
HIGHLIGHTS:
02
ISO • 4½-digit display, probes with higher
resolution up on request
STANDARD- 03
FUNCTIONS: • peak value memory 1000 measurments / s
04
CORR
• integrated horn
05 06
AUTO
OFF TARA
ADDITIONAL FUNCTIONS OF GMH 3156:
HOLD 13 14 15 16
• 2 GMSD/MSD-probes connectable.
LOGG
12
• difference measurement of two probes
LOGGER FUNCTION
for GMH31xx, GMSD, MSD, GDHs and pressure
measuring transducers.
Logger / EASYBus
max. display range: -19999 ... +19999 digit table top or suspended use. GDZ-09
Measuring range: corresponding to used probe Dimensions: 142 x 71 x 26 mm Product-ID: 601557
Overload: corresponding to used probe Weight: approx. 150 g, GMH 315x-ex:
Coupling adapter (NW5) made of brass with inside thread
G1/4“ (suitable for GDZ-12)
Resolution: corresponding to used probe approx. 190 g (incl. case)
GDZ-10
Accuracy: (device) ±0.1 % FS ±1 digit (at nominal Scope of supply: Device, battery, manual
Product-ID: 601559
temperature = 25 °C) Coupling adapter (NW5) made of brass for tube with 6 mm
* refer to note to EX-design types at page before
Pressure units: mbar, bar, Pa, kPa, MPa, mmHg, inside-Ø (suitable for GDZ-12)
PSI, mH2O, can be selected. GDZ-11
Probe connection: 1, GMH 3156/-ex: 2 Additional functions: Product-ID: 601561
6-pin screended lockable Averaging function: integrates the meas. values during a Coupling adapter (NW5) made of brass with
Mini-DIN-socket(s) for GMSD/ selectable period of time and then calculates the average outside thread G1/4“ (suitable for GDZ-12)
MSD-sensors. Automatic probe display value. GDZ-12
detection and setting of measuring Sea-Level-correction: when connecting an abs. pressure Product-ID: 601564
range upon plugging in of probe. probe the barom. air pressure can also be displayed
Simulator
62
further information on www.greisinger.de
Handheld instrument Pressure
TUBE, TUBE CLIPS, ADAPTER,
COUPLINGS, ETC. PLASTIC PRESSURE SENSORS WITH TUBE CONNECTION
Handheld instrument
20 FOR AIR AND
SES
19 NON AGGRESSIVE GA
17 18
23
22 General: Application:
21 for use with air and non aggressive gases
GMH 31xx, GDUSB: Type GMSD ... -K31, not suitable for water / liquids
GMH 51xx: Type: GMSD ... - K51
Display / Controller
29
SENSORS FOR MEASURING PRESSURE DIFFERENCE
27
32 for differential pressure measuring (both pressures are connected) as well as for relative pressure measu-
33 ring (pressure / vacuum, one terminal is left open)
28
GMSD 2,5 MR .. GMSD 25 MR .. GMSD 350 MR .. GMSD 2 BR .. GMSD 10 BR ..
Measuring range -1.999 ... -19.99 ... -199.9 ... -1000 ... -1.00 ... 10.00 bar
+2.500 mbar +25.00 mbar +350.0 mbar +2000 mbar
Overload max. 200 mbar max. 300 mbar max. 1 bar max. 4 bar max. 10.34 bar
GDZ-17 Resolution 0.001 mbar (0.1 Pa) 0.01 mbar (1 Pa) 0.1 mbar 1 mbar 10 mbar
Product-ID: 601574
Accuracy (typ.)
Logger / EASYBus
Screw-in connection for 6/4 tube with outside thread G1/4“
GDZ-18 hysteresis / ± 0.2 % FS ± 0.2 % FS ± 0.2 % FS ± 0.2 % FS ± 0.2 % FS
Product-ID: 601576 linearity
Tube clamp for 6/4 tube temperature influen- ± 1.0 % FS ± 0.5 % FS ± 0.4 % FS ± 0.4 % FS ± 0.4 % FS
GDZ-19 ce (from 0 - 50 °C)
Product-ID: 601578 GMSD ... - K31
Tube clamp for 8/6 tube Product-ID: 601039 601148 601154 601170 601183
(8 mm outside-Ø and 6 mm inside-Ø) GMSD ... - K51
GDZ-20 Product-ID: 601038 601149 601157 601171 601184
Product-ID: 601580
Screw-on connection made of brass for 6/4 tube with
inside thread G1/4“
GDZ-21
Product-ID: 601582 ABSOLUTE PRESSURE SENSORS
Transmitter
T-piece for 6/4 tubes
GDZ-22
for absolut pressure measuring
Product-ID: 601584 GMSD 1,3 BA .. GMSD 2 BA .. GMSD 7 BA ..
Coupling adapter (NW5) made of brass with tube
Measuring range 0 ... 1300 mbar abs. 0 ... 2000 mbar abs. 0.00 ... 7,00 bar abs.
connection 6/4 (suitable for GDZ-12)
Overload max. 4 bar abs. max. 4 bar abs. max. 10.34 bar abs.
GDZ-23
Product-ID: 601586 Resolution 1 mbar 1 mbar 10 mbar
Adapter G1/2“ Innen auf G1/4“ Außen, aus Messing Accuracy (typ.)
GDZ-27 hysteresis / linearity ± 0.2 % FS ± 0.2 % FS ± 0.2 % FS
Product-ID: 601594
temperature influence ± 0.4 % FS ± 0.4 % FS ± 0.4 % FS
Manometer profi le gasket (thickness 3mm, Cu)
(from 0 - 50 °C)
Temperature probe
for G1 / 4" hread
GMSD ... - K31
GDZ-28
Product-ID: 601192 601196 601200
Product-ID: 601597
Flat gasket (thickness 5 mm, Cu) for thread G1/2“ GMSD ... - K51
Product-ID: 601193 601197 601201
GDZ-29
Product-ID: 601599
Filter-Membrane incl. Luer-Locks (GDZ-32 and GDZ-33)
GDZ-30
Product-ID: 601601 Specifications: Options:
Adapter G1/2“ inside thread to tube 6/4 (w/o picture) Sensor: piezoresistive pressure sensor Ex-protection
GDZ-31 Pressure 2 connection pins for tubes 6 x
Product-ID: 606070 Higher probe accuracy
connection: 1 mm (6 mm inside-Ø and 4 mm by multi point calibration
Silicone tube 8/5 (8 mm outer / 5 mm inner) (2 bar at outside-Ø)
23 °C) temperature-resistant up to 200 °C, very fl exible Additional individual linearisation points are stored in
(fi gure similar to GDZ-04) Electronics: PC board with amplifi er and data sensor memory.
Simulator
memory for sensor data (mea- (not possible for GMSD 2,5 MR and GMSD 25 MR!)
GDZ-32 suring range / calibration etc.)
Product-ID: 607951 ISO-WPD5
integrated in sensor housing Product-ID: 602514
Luer-lock male to hose 6/4
Working temperature: 0 ... +50 °C Certifi cate of calibration: 5 points ascending,
GDZ-33 5 points descending
Product-ID: 607952 Relative humidity: 0 ... +95 % r.F. (non condensing)
Luer-lock female to hose 6/4 Storage temperature: -25 ... +70 °C
GWA 1214 Housing: ABS plastic with suspension eye,
Product-ID: 603979 dimensions do not incl. conn. pin:
Adapter G1/2“ inside thread to G1/4“ outside thread 68 x 32.5 x 15 mm, dimensions
Alarm / Protection, Level
(without picture) with connection pin: 68 x 32.5 x
GOG-N 27.5 mm.
Product-ID: 603047 Weight: approx. 75 g (...-K51: approx. 82 g)
needle, Ø 0.9 mm - suitable to Luer-Lock male Device connection:
(5 pieces) (without picture)
GMSD ... - K31: 1.2 m PVC connection cable,
GMSD ... - ex: screened with integral 6-pin Mini-
DIN-plug, lockable
GMSD ... - K51: 1 m PVC connection cable, scree-
ned with 7-pin bayonet plug
63
for additional accessories p.r.t. page 72 - 78
STAINLESS STEEL PRESSURE SENSORS
Handheld instrument
E
FOR AIR, AGGRESSIV
GASE AND LIQUIDS
S
Stainless steel pressure sensors without cable
Connection cable MSD-K31 or MSD-K51 has to be ordered separatly MSD -20/60 MRE
(Accessories) not suited for aggressive media, water, etc.,
no Ex design and no option „higher accuracy“ available
General:
for use with GMH31xx, GMH 51xx and GDUSB 1000 Rel. pressure Measuring range Overload Resolution
MSD 25 MRE 0.00 ... 25.00 mbar max. 500 mbar 0.01 mbar
Application: Product-ID: 606904
air, aggressive gases, aggressive liquids / water, etc. MSD -20/60 MRE -20.00 ... 60.00 mbar max. 500 mbar 0.01 mbar
Product-ID: 606765
Abs. pressure Measuring range Overload Resolution
MSD 1 BAE 0 ... 1000 mbar abs. max. 5 bar abs. 1 mbar Specifications:
Product-ID: 600583 Sensor: stainless steel pressure sensor (parts coming into contact with
Logger / EASYBus
memory. (not available for MSD 25 MRE and MSD -20/60 MRE)
MSD 1 BRE 0 ... 1000 mbar rel. max. 5 bar rel. 1 mbar
Product-ID: 600612 ISO-WPD5
Product-ID: 602514
MSD 2,5 BRE 0 ... 2500 mbar rel. max. 10 bar rel. 1 mbar
Certifi cate of calibration: 5 points ascending, 5 points descending
Product-ID: 600614
MSD 4 BRE 0 ... 4000 mbar rel. max. 17 bar rel. 1 mbar Accessories:
Product-ID: 600616
MSD-K31
MSD 6 BRE 0 ... 6000 mbar rel. max. 35 bar rel. 1 mbar Product-ID: 600657
Product-ID: 600618 Connection cable for use with GMH 31xx / GDUSB 1000
MSD 10 BRE 0.00 ... 10.00 bar rel. max. 35 bar rel. 10 mbar 1.2 m PVC connection cable, screened with integral 6-pin Mini-DIN-plug and M16-socket
Product-ID: 600620 (IP 54)
MSD 25 BRE 0.00 ... 25.00 bar rel. max. 50 bar rel. 10 mbar MSD-K51
Product-ID: 600622 Product-ID: 603809
Connection cable for use with GMH 51xx
MSD 40 BRE 0.00 ... 40.00 bar rel. max. 80 bar rel. 10 mbar 1 m PVC connection cable, screened with 7-pin bayonet plug
Simulator
64
further information on www.greisinger.de
Handheld instrument Pressure
Handheld instrument
FUNCTIONS:
HIGHLIGHTS:
AUTO
OFF • integrated pressure sensor
Display / Controller
MIN
MAX
O / S-
CORR
TARA
ALARM LOGG
Logger / EASYBus
Type specific data: GMH 3161 - ... GMH 3181 - ... GMH 3161 - ... - ex GMH 3181 - ... - ex
Display: 2 x 4½-digit LCD 2 x 4½-digit LCD 2 x 4½-digit LCD 2 x 4½-digit LCD
Sensor: piezoresistive differential pressure sensor internally built into the instrument. Suitable for air and non-aggressive gases.
(Note: Not suited for water!)
Pressure connection: 2 pressure port for universal 6 x 1 mm (4 mm hose inside diameter) or 8 x 1 mm (6 mm hose inside diameter) plastic tubing
Output: interface interface or AAG interface * interface or AAG*
- serial interface: x x x x
Transmitter
- analog output: -- 0 - 1 V, freely adjustable -- 0 - 1 V, freely adjustable
(resolution 12 bit) (resolution 12 bit)
Power supply: 9 V-battery, d.c. connector 9 V-battery, d.c. connector 9 V-battery, d.c. connector * 9 V-battery, d.c. connector *
suitable 9 V-battery, d.c. connector for external 10.5-12 V direct voltage supply. (suitable power supply: GNG10/3000)
Sensor adjustment: digital offset and scale input digital offset and scale input digital offset and scale input digital offset and scale input
Peak value memory: -- ≥1 ms -- ≥1 ms
Measuring cycle: „slow“ 4 measurements / s 4 measurements / s 4 measurements / s 4 measurements / s
„fast“ (with filter) -- ≥ 1000 measurements / s -- ≥ 1000 measurements / s
„peak-detect“ -- ≥ 1000 measurements / s -- ≥ 1000 measurements / s
Temperature probe
Averaging function: -- x -- x
Power consumption: approx. 0.6 mA approx. 0.6 mA (slow mode) approx. 0.6 mA approx. 0.6 mA (slow mode)
max. 2.5 mA (fast = 1000 Hz) max. 2.5 mA (fast = 1000 Hz)
Working condition: -25 ... +50 °C, 0 ... +95 % RH (non-condensing) -10 ... +50 °C, 0 ... 95 % RH (non-condensing)
Housing: 142 x 71 x 26 mm (without pressure connection pin - pin approx. 11 mm protruding at front side of device), impact-resistant ABS plastic housing.
Front side IP65 integrated pop-up clip for table top or suspended use.
Weight: approx. 165 g approx. 170 g approx. 205 g (incl. leather case) approx. 210 g (incl. leather case)
Scope of supply: Device, battery, manual Device, battery, manual Device, battery, manual Device, battery, manual
GMH 3181:
Low power logger mode: (only in measuring cycle „slow“) Only one measurement
carried out at the end of the respective logger cycle. The battery life is considerably
prolonged. For long-term recordings (e.g. leaktest).
Alarm / Protection, Level
65
for additional accessories p.r.t. page 72 - 78
FINEST MANOMETER / MANOMETER FOR OVER/UNDER PRESSURE AND PRESSURE DIFFERENCE.
Handheld instrument
Option higher accuracy available: no range: (-1.00 ... 25.00 mbar) +70.00 mbar ... - 07 ... - 07B
Pressure 2 Overload: max. 100 mbar max. 1000 mbar Measuring -10.0 ... +350.0 -10.0 ... +420.0 mbar
connection: range: mbar (-7.5 ... 315.0 mmHg)
Resolution: 1 Pa (0.01 mbar) 0.01 mbar
Overload: max. 1 bar max. 1 bar
additional bar, kPa, PSI, bar, Pa, kPa, PSI,
For type specific data please refer to page 65. Resolution: 0.1 mbar 0.1 mbar (0.1 mmHg)
pressure units: mmHg, mH2O mmHg, mH2O
*1 measuring range possible by changing the pressure
connection ports Accuracy: (typ. values) additional bar, kPa, MPa, bar, kPa, MPa,
*2 without changing the pressure connection ports pressure units: PSI, mmHg, mH2O PSI, mH2O
hysteresis and ± 0.3 % FS ± 0.1 % FS
linearity: Accuracy: (typ. values)
temperature- ± 0.4 % FS ± 0.4 % FS hysteresis and ± 0.2 % FS ± 0.1 % FS
influence from linearity:
0 - 50 °C: temperature- ± 0.4 % FS ± 0.4 % FS
Option higher no already integrated influence from
accuracy 0 - 50 °C:
available:
Simulator
66
further information on www.greisinger.de
Handheld instrument Pressure
MANOMETER FOR OVER/UNDER
PRESSURE AND PRESSURE DIFFERENCE. VAKUUM- OR BAROMETER ACCESSORIES
Handheld instrument
Options:
Higher sensor accuracy
by multi point calibration
ISO ISO Note: not possible for all device types!
ISO-WPD5
Product-ID: 602514
Certifi cate of calibration: 5 points increase, 5 points
decrease.
ISO-WPD10
Product-ID: 602565
Certifi cate of calibration: 10 points increase, 10 points
decrease.
Display / Controller
Accessories and spare parts:
GNG 10/3000
Product-ID: 600273
plug-in power supply
GRS 3100
Product-ID: 601097
interface converter, RS232, electrically isolated
USB 3100 N
Product-ID: 601092
interface converter, USB, electrically isolated
GDZ-01
Product-ID: 601541
Logger / EASYBus
PVC-tube (5 bar) 6/4 (6 mm outside-Ø, 4 mm inside-Ø)
FOR ABSOLUTE GDZ-08
EMENT Product-ID: 601555
PRESSURE MEASUR Double adapter for 6/4 tube to 6/4 tube
GDZ-18
GMH 3161-13 GMH 3161-12 Product-ID: 601576
tube clamp for 6/4 tube
Product-ID: 600409 Product-ID: 600407
GDZ-21
Device -100 ... 2000 mbar (± 2000 mbar *1) Device 0 ... 1300 mbar abs.
Product-ID: 601582
GMH 3181-13 GMH 3181-12 T-piece for 6/4 tubes
Product-ID: 600421 Product-ID: 600419 GKK 3000
Product-ID: 601048
Device -100 ... 2000 mbar (± 2000 mbar *1), with Device 0 ... 1300 mbar abs., with data logger
case (275 x 229 x 83 mm) with cut-outs for GMH3xxx
data logger Specifications:
Transmitter
for miscellaneous accessories p.r.t. pages 62 - 63
Specifications: Measuring range: 0 ... 1300 mbar abs.
Measuring range: -100 ... 2000 mbar Overload: max. 4 bar abs.
(optional: -1000 ... 2000 mbar)
Resolution: 1 mbar
Overload: max. 4 bar Special design type:
Pressure units: mbar, bar, kPa, MPa, PSI, mmHg,
Resolution: 1 mbar mH2O Ex-protection ( II 2 G Ex ib IIC T4 Gb)
additional pressure bar, kPa, MPa, PSI, mmHg, mH2O Accuracy: (typ. values) device type with Ex-protection
units:
hysteresis and linearity: ± 0.2 % FS
Accuracy: (typ. values)
temperature-influence from 0 - 50 °C: ± 0.4 % FS
hysteresis and linearity: ± 0.2 % FS
Option higher accuracy available: yes
Temperature probe
temperature-influence from 0 - 50 °C: ± 0.4 % FS
Pressure connection: 1
Option higher accuracy available: yes
Pressure connection: 2 Sonderfunktion:
SeaLevel-correction:
Option: The barometric air pressure can also be related to sea
MB -1...2 BAR level „zero“. (Correction of air pressure is achieved by
measuring range: -1000 ... 2000 mbar *2 entering m above „zero“)
For type specific data please refer to page 65. For type specific data please refer to page 65.
*1 measuring range possible by changing the pressure
connection ports
*2 without changing the pressure connection ports
Simulator
COMPLETE SOLUTIONS
ertificate
libration C
Werkska
ersche
Werkskalibri hrung auf
Dieser die Rückfü llung
entiert zur Darste ung
dokum Normale nstimm
nationale ten in Überei
ation item n
Complete Solution incl. certifi cate of calibration Complete Solution incl. certifi cate of calibration
/ Calibr der Einhei tionale
Interna (SI).
genstand mit dem tem (KG) ist
Kalibrierge GMH 3710 IN Kl. B Einheitensys
cial design
nstand
ergege racht, die
GTF 101, D tigung / Spe Am Kalibri arke angeb dieses
Sonderanfer eine Klebem ernummersowie dem
Kalibri ines
mit der ersche
Werks kalibri Jahr
at und
Kalibriermon
WPD5 (5 points ascending / descending) and case WPD5 (5 points ascending / descending) and case
number en wurde
.
mer / Serial verseh
Einhaltung zur
einer
Seriennum 32402 Für die n Frist erung ist
essene
angem g der Kalibri h.
Wiederholun er verant
wortlic
bH der Benutz
acturer technik Gm
/ Manuf
Hersteller GHM Mess eisinger
GKK 3000. GKK 3000.
Alarm / Protection, Level
ents
Standort Gr -Straße 26 n certific
ate docum s,
Hans-Sachs nstauf This ca
ration
libratio onal standard
eability to natits of
93128 Rege the trac the uni to the
which realize s according s (SI).
measurement ystems of unit o the
mer
er / Costu International Sn label fixed t mber,
Auftraggeb The calibratio m contains nu ration.
libration.
calibration ite e calib
the ca
ar of th
year of
and ye
th and ible for an
GMH 3161-12-WPD5
r month espons al.
/ Order numbe .08.2013 The client is r libration interv
riate ca
Auftra gsnummer 001029 / 22 approp
tion
/ Date of calibra
rierung
der Kalib 10.09.2013
Datum
er of pages werden.
n / Numb verbreitet ratoriums.
der Seite rt weiter Kalibrierlabo
Anzahl 3 ndert
erände
unverä llenden laboratory.
ndig und g des ausste the issuing
sion of
Product-ID: 602685
nur vollstä
in darf Genehmigun Gültigkeit. ept with the permis
ersche en der keine
Werkskalibri ungen bedürf chrift haben full exc
Dieser oder Änderine ohne Unters other than in
oduced
Auszüge ersche ay not be repr re not valid. eiter
Werkskalibri n certificate m ut signature a Sachbearb nsible
libratio s witho
This ca
tion ce rtificate
Perso n respo
Calibra rierla bors
Kalib
Complete Solution incl. certifi cate of calibration
tory
Leiter des ation labora
calibr
Head of
Datum Hengl
Date Florian
ine
Stephan He
WPD5 (5 points ascending / descending) and case
er 2013
10. Septemb
GKK 3000.
67
for additional accessories p.r.t. page 72 - 78
VAKUUM-/BAROMETER OR
FINE MANOMETER MANOMETER MANOMETER
Handheld instrument
ESSURE
FOR OVER/UNDER PR
Logger / EASYBus
FOR OVER/UNDER PR
ESSURE FOR ABSOLUTE
RENCE OR PR ES SU RE DIFFERENCE PRESSURE
OR PR SURE DIFFE
ES
*1 measuring range possible by changing the pressure *1 measuring range possible by changing the pressure Scope of supply: Device, battery, manual
connection ports connection ports
Tubes, clamps, adapters, accessories, etc. p.r.t. pages 62/63
Tubes, clamps, adapters, accessories, etc. p.r.t. pages 62/63 Tubes, clamps, adapters, accessories, etc. p.r.t. pages 62/63
68
further information on www.greisinger.de
Handheld instrument Pressure
ALTIMETER / BAROMETER / THERMOMETER
BAROMETER PRECISION BAROMETER
Handheld instrument
ISO ISO
AUTO AUTO
OFF OFF
BAT BAT
MIN MIN
Display / Controller
MAX MAX
O / S- O / S-
CORR CORR
TARA TARA
ENT
USAGE IN MEASUREM
Logger / EASYBus
FOR PROFESSIONAL
LL
TECHNOLOGY AS WE
ORTS
AS IN SPARE TIME SP
Transmitter
off, min/max-value, tara-function,
Specifications: Functions: zero-, slope-,and sea level-ad-
Measuring ranges: 300.0 ... 1100.0 mbar (hPa) abs. • manual offset and slope-adjustment justment slide switch for unit
225.0 ... 825.0 mmHg abs. • sea level-adjustment possible selection.
Max. Overload: 4000 mbar or 3000 mmHg • tendency-meter, summing-function (ascendency, Power supply: 9 V battery
descendency, overall) Power consumption: approx. 50 µA
Accuracy: ± 2.0 mbar (typ. at 0 - 50 °C) • over 6.000 operating hours
(at nominal (= over 6.000 operating hours)
temperature) Specifications: System permanent self-diagnosis and
Sensor: piezoresistive abs. pressure Notifications: error indication.
Measuring ranges:
sensor integrated in housing. Housing: impact resistant ABS housing
Temperature: -10.0 ... +50.0 °C, or
Nominal temperature: 25 °C Dimensions: approx. 106 x 67 x 30 mm
Temperature probe
14.0 ... +122.0 °F,
Operating -25 ... 50 °C, 0 ... 95 % RH (H x W x D)
Pressure: 300.0 ... 1100.0 mbar abs. or
temperature: (non-condensing) 225.0 ... 825.0 mmHg abs. Weight: approx. 135 g (incl. battery)
Display: 4½-digit, 12 mm high LCD-display High: -500 ... -200 m, res. 1 m or Scope of supply: Device, battery, manual
Pushbuttons: 3 membrane key for ON/OFF, -1640 ... -655 ft, res. ~5 ft
min-/max-value memory, tara, etc. -200 ... 2000 m, res. 0.5 m or Accessories and spare parts:
Power supply: 9 V battery -654 ... 1999 ft, res. ~2 ft GB 9 V
2000 ... 9000 m, res. 1 m or Product-ID: 601115
Power consumption: approx. 60 µA 2000 ... 19999 ft, res. ~5 ft spare battery
(= 5000 operating hours)
Measuring units: hPa / mbar, mmHg, °C, °F, m, ft ISO-WPD 5
Zero point-adjustment: manually Product-ID: 602514
Max. Overload: pressure: 4000 mbar or 3000
Slopeadjustment: manually mmHg 5 points rising, 5 points falling
Sea level correction: Barometric values can be Accuracy: (at nominal temperature = 25 °C) GKK 252
converted to sea level (therefore Product-ID: 601056
the input of the current altitude is Temperature: ±1 % FS ± 1 digit small case (235 x 185 x 48 mm) with foam lining
Simulator
69
for additional accessories p.r.t. page 72 - 78
UNIVERSAL PRESSURE
MEASUREMENT SYSTEM VOLUMETRIC FLOW ANEMOMETER FLOW SPEED MEASURING DEVICE
Handheld instrument
HIGHLIGHTS: FUNCTIONS:
MIN
MAX
Display / Controller
1000 MEASUREMENTS
PER SECOND
GDUSB 1000
Product-ID: 600271
Full set incl. software for high-speed live measure-
Logger / EASYBus
ment data logging GDUSB FastView (p.r.t. page 78)
Applications: GVA 0430 TA 888 N
• Test rigs and laboratory experiments Product-ID: 603526 Product-ID: 602574
• Detection of pressure peaks Volumetric fl ow anemometer Thermal anemometer
• Monitoring system pressure curves e.g. for process General: General:
technology, engineering, etc.
• Live and offl ine displaying of measuring data of several • fl ow rate • high accuracy
GDUSB 1000 e.g. for data evaluation and logging, for • volumetric fl ow • smallest and slow air fl ows measurable
optimization of processes and other statistics • temperature • slimline telescopic probe
• Multi-channel measurements with high recoding rate
• Test setups or on-site recordings with GDUSB 1000 Application: Application:
Ventilation and air conditioning technology, industrial Classic application of the TA 888 N is fl ow measurement
Functions: drying technology, meteorology, water sport, air gliding, in ventilation ducts. Due to its high resolution of 0.01 m/s
The GDUSB 1000 adapter allows to connect a standard etc. even smallest changes of the fl ow velocity can be easily
Transmitter
similarly to GMH handheld devices or EASYBus modules Accuracy:
and precision-NTC
(up to 32 measurements per second). Then a long term
recording can be archived with the software EBS 20M / Meas. interval: 1 measuring / s Flow: 0 ... 1 m/s ±0.25 m/s
EBS 60M (2 measurements per second). Display: 2-line LCD display, 37 x 42 mm 1 ... 5 m/s ±0.5 m/s
5 ... 10 m/s ±1.0 m/s
Working temperature: -10 ... +50 °C 10 ... 15 m/s ±2.0 m/s
Specifications:
Relative humidity: 0 ... +95 % RH (non-condensing) Temperature: ±1 °C
Measuring ranges: depends on connected sensor
Storage temperature: -10 ... +50 °C Display: LCD-Anzeige
Max. range: -19999 ... +19999 digit
Interface: serial interface RS232 Meas. interval: approx. 0.8 s
Pressure units: mbar, bar, Pa, kPa, MPa, mmHg,
PSI, mH2O, selectable, depending Special function: averaging of 8 meas. points, Working temperature: 0 ... 50 °C
on connected sensor averaging throughout meas. time,
volumetric fl ow calculation Relative humidity: 0 ... 80 % RH
Measuring rate: 1000 measurements / s (= 1 ms)
Power supply: 9 V battery, external power supply Power supply: 9 V battery, external power supply
Accuracy: ±0.2 % FS (at nominal tempera-
Operating time: 100 hours (with alkaline) Dimensions: - Housing: 210 x 75 x 50 mm
ture = 25 °C)
(H x W x D)
Simulator
70
further information on www.greisinger.de
Handheld instrument
Handheld instrument
Display / Controller
VIA LIGHT AND
TH MEASUREMENT
VELOCITY AND LENG REFLECTING LABEL
L
VIA MEASURING WHEE
Logger / EASYBus
GSH 8922 rotaro 3 ecotach
Product-ID: 602739 Product-ID: 603861 Product-ID: 603673
Phonometer Rotation speed measuring device via light and Rotation speed measuring device via light and
General: refl ecting label or measuring tip refl ecting label
Compensation of the background-noise for measuring Application: Application:
sound-sources in the fore-ground. Weighting of the The handheld tachometer rotaro 3 is useful at the installa- The handheld tachometer ecotach is useful at the
sound level via two weighting-fi lters according to the IEC tion and setup of plants and machinery as well as for ser- installation and setup of plants and machinery as well as
standard. Assignation of the max/min value during one vice application, monitoring production processes or use at for service application, monitoring production processes
measuring period. development laboratory. The rotaro 3 can measure rotary or use at development laboratory. It can measure rotary
speed of for example motors, turbines, pumps as well as speed of for example motors, turbines, pumps as well as
Specifications: stirring devices, centrifuges and haulage installations, foil stirring devices, centrifuges and haulage installations.
Measuring ranges: 30 - 130 dB (6 ranges) or textile manufacturing units, coil and transformer winding
Transmitter
30 - 80, 40 - 90, 50 - 100, machines, machine tools, etc. Furthermore it can measure Specifications:
60 - 110, 70 - 120, 80 - 130 dB running speed and length of foils and band of all kind. Measuring range: 1 ... 60.000 rpm
manual or automatic selection of
Specifications: Accuracy: ± 0.02 % of m.w. (± 1 digit)
range
Measuring range: Measuring distance: max. 450 mm
Resolution: 0.1 dB
rpm: 1.00 ... 99.999 min-1 Measuring principle: optical
Accuracy: ±1.5 dB
(optical measurement) Power-off: automatically after 30 s
Norms: ANSI S1.4 and IEC 651 Type 2 1 ... 19.999 min-1 Display: 5-digit LCD display for measuring
Frequency rate weighted: 31.5 Hz - 8 kHz (mechanical measurement) value with fl oating point, measu-
Evaluation 2, selectable Velocity: Ø 0.1 m: 0.10 ... 1999 m/min ring unit, trigger signal, low-battery
weight filter: Ø 6“: 0.10 ... 1524 m/min warning, notifi cation when battery
Temperature probe
Type A: evaluation of the spectrum in (other units possible: m/sec, ft/ is low
accordance with the perceptive min, in/min ...) Power Supply: 2 x AA battery or accumulator
faculties of the human ear. Length: 0 ... 99999 m / ft / in Working temperature: 0 ... 50 °C
(Sound insolation establishment, Accuracy:
environmental analysis) Housing: plastic ABS
rpm: ± 0.02 % of m.v. (± 1 digit) Approval: CE
Type C: linear evaluation of spectrum
(sonic-analysis of engines or Measuring distance: max. 600 mm Dimensions: 145 x 60 x 28 mm (H x W x D)
machines) Measuring principle: optical / mechanical Weight: 147 g
Weight of time factor: fast or slow Memory function: min- / max- value memory, Scope of supply: Rotation speed measuring device
Microphone: 6 mm Electret condensator average and last value incl. refl ecting labels, transportati-
microphone Power-off: automatically after 30 s on slip case, battery, manual
Display: 3½-digit LCD-backlight display, Display: 5-digit LCD display with 10 mm
additionally quasi-analog bar height of digits and fl oating point
graph at range change
Simulator
71
for additional accessories p.r.t. page 72 - 78
HANDHELD INSTRUMENTS - ACCESSORIES
Handheld instrument
GKK 1105
GKK 252
GKK 3000
GKK 4400
Display / Controller
GKK 3100
GKK 1100
Color may vary.
GKK 3500
Logger / EASYBus
GKK 1420
GKK 3600
GKK 5240 with foam lining
for individual adaption
GKK 3700
GKK 3700
Product-ID: 601064
with foam lining for universal use
(450 x 360 x 123 mm)
Simulator
K 50 RE MOUNT
GMH 1300
SILICONE PROTECTION COVER Product-ID: 601091
Alarm / Protection, Level
72
further information on www.greisinger.de
Handheld instrument
Handheld instrument
LAN 3100
NEW !
WLAN 3100
Display / Controller
ST-R1 ST-R2 ST-KO ST-KF
Logger / EASYBus
Nappa leathern device protection bag with 1 round Nappa leathern device protection bag with 2 round cut-
of supply)
cut-out for sensor connection outs for sensor connection (1 x round, 1 x rectangular) Accessories:
suitable for: suitable for: power supply unit, USB adapter, manual, driver CD
GMH 3111, GMH 3151, GMH 3161-12, GMH 3181- GMH 3330, GMH 3350, GMH 3830, GMH 3850
12, GMH 3431, GMH 3451, GMH 3611, GMH 3651,
GMH 3692, GMH 3710, GMH 3750, GMH 175 WLAN 3100
ST-KO Product-ID: 606061
ST-R1-US Product-ID: 601078 Gigabit-Ethernet or Wireless-LAN to USB converter
Product-ID: 605929 device protection bag, without cutouts
General:
Nappa leathern device protection bag with 1 round suitable for: GTD 1100, GPB 3300
cut-out for sensor connection For accessing EASYBus modules, GMH handheld devices
with strap with interface or GDUSB 1000 via local network or via
WiFi. With 2 USB ports for direct connection of one or
more EBW 3, USB 3100N or GDUSB 1000 (up to 15 with
Transmitter
an USB hub). With an USB to serial converter for
connection of an EBW 1, EBW 64 or EBW 240.
ST-KN Scope of delivery:
Product-ID: 601080 WLAN 3100, mains adapter, USB to serial converter,
ST-R2 device protection bag with rectangular cut-out for manual, CD
Product-ID: 601068 sensor connection
Nappa leathern device protection bag with 2 round suitable for: GTH 1150, GTH 1170
cut-outs for sensor connection
suitable for:
GMH 3156, GMH 3161-002, GMH 3161-01, GMH
3161-07, GMH 3161-13, GMH 3181-002, GMH
3181-01, GMH 3181-07, GMH 3181-13
Temperature probe
ST-KR
Product-ID: 601082
device protection bag with round cut-out (central)
suitable for:
GTH 175, GOX 20, GOX 100, GLF 100,
ST-R3 GLF 100 RW
Product-ID: 605931
Nappa leathern device protection bag with 2 round
cut-outs for sensor connection
suitable for: GMH 3511 / 31 / 51
ST-KF
Product-ID: 601084
device protection bag with punched-out slot for a
Simulator
sensor head
ST-N1 suitable for:
Product-ID: 601070 GFTH 95, GFTH 200, GFTB 200, GTH 200 air
Nappa leathern device protection bag with
1 rectangular cut-out for sensor connection
suitable for:
GMH 3210, GMH 1150, GMH 1170
ST-KD
Product-ID: 601086
Alarm / Protection, Level
device protection bag with 2 round cut-outs
suitable for:
ST-N2 GDH 200 - 07, GDH 200 - 13, GDH 200 - 14,
Product-ID: 601072 GMR 110
Nappa leathern device protection bag with
2 rectangular cut-outs for sensor connection
suitable for:
GMH 3230, GMH 3251
73
for additional accessories p.r.t. page 72 - 78
HANDHELD INSTRUMENTS - ACCESSORIES
Handheld instrument
GLG 1300
USB 3100 N
GNG 10
USB Adapter
Display / Controller
GAM 3000
GB 9 V GLI 9 V GAK 9 V
Picture similar GNG 10 / 3000
GRS 3105
cables VEKA3105. Mini-DIN plug, 4-pin, with lock and for self installation
nectors: 1 x bayonet socket LTW 4-pole, 1 x loose
GSA 9S-25B ends, with ferrules, application: GMH 5xxx.
Product-ID: 601107
Connection adapter (9-pin Dsub-adapter <=> 25-pin
Dsub-socket)
USB-Adapter
Product-ID: 601109
for connection of a RS232-interface converter to the
USB-interface
74
further information on www.greisinger.de
Handheld instrument
SOFTWARE
Handheld instrument
Display / Controller
Logger / EASYBus
EASYBus Configurator
GDUSB FastView
EASYControl net
GSOFT 3050
GSOFT 40k
MINISOFT
EBS 20M
EBS 60M
Application:
● ● ●
Transmitter
GMH 3xxx and GMH 5xxx
Temperature probe
Several interfaces usable at the same time ●* ●* ● ***
Live measuring value recoding and
displaying ● ● ●
Number of data points (recommendation) up to 1 Mio. from 1 Mio. up to 10 Mio.
Change label ● ● ● ●
Network compatible
(Simultaneous access to data by several PCs) ●
Access via SQL queries possible ●
Pilot EBB Out ● **
Alarm / Protection, Level
Subject to a charge ● ● ● ●
Long-term
Application Lab, test rig Read-out data logger Start-up Lab, test rig
monitoring
75
for additional accessories p.r.t. page 72 - 78
SOFTWARE FOR MEASUREMENT DATA ACQUISITION
Handheld instrument
Display / Controller
Logger / EASYBus
Simultaneous use of different serial Bus-Systems: EASYBus, GMH handheld devices,
GDUSB 1000 Live:
• Constantly updating data
Application: • Time assignment of the data
• On-site recording • Load ancient data and complete them with „live“ data
• Process and system control, monitoring of climate and buildings
• Real time monitoring of measuring data i.e for data evaluation and logging for cost Peripheral:
listings, overview of consumption, optimisation of processes, and other statistics • Uncoupling of data acquisition, data storage and visualisation
• Component communication via LAN
Functions: • Data visualisation by local network
• Simultaneous use of several serial interfaces
Temperature probe
• Simultaneous use of different serial converters Controlled:
• Quick and easy installation and handling • Trigger EBB Out switching channels via EASYBus
• Freely scaleable diagrams and alarm limits
• Visualization of actual measurements values Clear:
• Trusted data storage via SQL database
• Data export • Different kinds of visualisation (table, digital, tachometer, chart)
• Display multiple graphs “live” in one chart
Measuring Cycle: • Tooltips (with status information) for each measuring point in the chart
• Blinking symbols on error or status message in the visualisation
smallest possible measuring cycle: 500 ms • Displaying error- and status messages.
• Displaying min- max- and mean value of the sensors
System requirements: • Generate reports and store them as PDF, Excel or Word fi le
1GHz CPU, 1GB RAM, 100 MB HDD, 1 available USB Port
Microsoft Windows 7 SP1 (32 or 64 Bit) System requirements:
(not executable with Windows RT, ARM or Intel Itanium based Windows systems) 1GHz CPU, 1GB RAM, 100 MB HDD, 1 available USB Port
Microsoft Windows 7 SP1 (32 or 64 Bit)
Simulator
(not executable with Windows RT, ARM or Intel Itanium based Windows systems)
Alarm / Protection, Level
76
further information on www.greisinger.de
Handheld instrument
LOGGER-SOFTWARE
Handheld instrument
Display / Controller
Logger / EASYBus
GSOFT 40K GSOFT 3050
Product-ID: 601145 Product-ID: 601336
Windows-software for EASYLog and T-Logg with logger. Windows-software for GMH3xxx- and GMH5xxx-series with logger.
Functions: Functions:
• Display of the device status information • Display of the GMH-information
• Setting the alarm function • Setting of the alarm function
• Operation of the logger function • Operation of the logger function
- Start - start
- Stop - stop
- Cycle time - Cycle time
- Read data - Read data
Transmitter
- Delete data - Delete data
• Chart display • Diagram display
- Various measuring sequences in one diagram - The Logger data can be displayed in the form of a diagram
- Real-time axis - Real-time axis
- Zoom function - Zoom function
- Measurement points, legend and measurement cursor displayed or hidden - Display of legend and marking of measuring points can be switched on / off
- Add comments - Add comments
- Storing the window position - Storing the window position
• Export function • Export function
- Data export of series of measurements as a CSV fi le - Data export of series of measurements as a CSV fi le
• Print function • Logger data print-out
- Print out the data as a table and/or trace - Data can be printed as tables or as diagram
Temperature probe
• Multilingual • Multilingual
- German, English, Czech and French - German, English, Czech and French
• Automated retrieval and archiving
- Readout of all connected data loggers to be fi xed times System Requirements:
- Automatic storage of measured values on the hard disk 1 GHz CPU, 1 GB RAM, 100 MB HDD
- Automatic export of measurement values as a CSV fi le Windows 7 SP 1 (32 or 64 Bit)
- Automatic printout interface converter
for GMH 3000: GRS 3100, GRS 3105 or USB 3100 N
System Requirements: for GMH 5000: USB 5100
1 GHz CPU, 1 GB RAM, 100 MB HDD (executable from Windows XP, not executable with Windows RT, ARM or Intel Itanium
Windows 7 SP 1 (32 or 64 Bit) based Windows systems)
interface converter
for GMH 3000: GRS 3100, GRS 3105 or USB 3100 N
for GMH 5000: USB 5100
(executable from Windows XP, not executable with Windows RT, ARM or Intel Itanium
based Windows systems)
Simulator
Alarm / Protection, Level
77
for additional accessories p.r.t. page 72 - 78
HIGH-SPEED LIVE MEASUREMENT SOFTWARE CONNECTION
Handheld instrument
IPEmotion (www.IPETRONIK.de)
Plug-in (www.inray.de)
PROFILAB Expert 4.0
Protocol description
(www.greisinger.de)
GDUSB 1000-DLL
(windows library)
(windows library)
(windows library)
GMH 3000-DLL
Connection for
EASYBus-DLL
Display / Controller
GMH 3xxx
GMH 5xxx ● ● ● ●
EASYBus und
EASYLog ● ● ● ● ●
FOR GDUSB 1000 TLogg ● ●
GDUSB 1000 ●
Start, stop, delete,
read-out logger ● ●
Visual Studio,
Visual data
Logger / EASYBus
System requirements:
1GHz CPU, 1GB RAM, 100 MB HDD, 1 available USB Port
Microsoft Windows 7 SP1 (32 or 64 bit)
(not executable with Windows RT, ARM or Intel Itanium based Windows systems) ProfiLab-Expert 4.0
This software uses open-source components under LGPL conditions.
Product-ID: 603510
The license terms of this software provide further information. Development of metrological control
Temperature probe
General:
The software Profi Lab-Expert allows you to develop your own digital or analog measuring
technology requirement. It doesn‘t matter if you want to create analog measurements
or digital controls - you can realize it all. And for all this you don‘t have to write a single
program-line!
Profi Lab-Expert supports our devices of the GMH3xxx-Serie with serial interface,
GCO100, GFTB100/GRS, as well as all EASYBus-devices. Every device will be displayed
in your project like a normal component. You only have to connect his inputs and outputs.
Compiler inclusive !
Profi Lab-Expert is equipped with an integrated compiler. The compiler can create exe-
cutable fi les for stand-alone applications that run on systems without Profi Lab-Expert.
The distribution of these compiled applications is unlimited, so Profi Lab-Expert become a
complete and professional developers system.
System requirements:
Simulator
Windows 7 SP 1 (32 or 64 Bit)
interface converter
for GMH 3000: GRS 3100, GRS 3105 or USB 3100 N
for GMH 5000: USB 5100
(executable from Windows XP, not executable with Windows RT, ARM or Intel Itanium
based Windows systems)
GMH 3000.DLL
Alarm / Protection, Level
Product-ID: 603027
Windows-functional library for interface communication to integrate all GMH
3xxx/5xxx device functions.
EASYBUS.dll
Product-ID: 601155
Windows-function library for interface communication EASYBus - PC
78
further information on www.greisinger.de
Display / Controller
DISPLAY
Handheld instrument
GIA 0420 WKT - ex
GIA 0420 VOT - ex
GTH2428/4 ../5
GTH2448/1
GIA 2448
GIA 2000
EDT 24...
GIA ... N
pH 9648
TA 9648
ET 2011
Display / Controller
Application:
Dimensions 24 x 48 24 x 48 24 x 48 24 x 48 24 x 48 24 x 48 48 x 96 48 x 96 48 x 96 35 x 77 35 x 77 Special size
Measuring input
normalized signal ● ● ● ● ● ● ● ● ●
Measuring input temperature
(Pt100 / Pt1000) ● ● ● ●
Measuring input temperature
(thermo elements) ● ● ●
Measuring input NTC ●
Logger / EASYBus
Measuring input frequency ●
Universal input ●
Messeingang PH / LF ●
- Protection ● ● ●
Device information:
Transmitter
Catalogue page 80 80 81 81 81 81 89 90 92 98 98 100 100 100 100
CONTROLLER
GIR 2002 NS / DIF ...
Temperature probe
GIR 2000 Pt ...
GIR 230 DIF...
MAXVU 16 / 8
GRA ... WK
GRA ... VO
GIR 230 ...
GIA 20 EB
GIR 2002
SD 9648
GIR 300
GIR 360
UZ 9648
LF 9648
A 9648
V 9648
KM
Application:
Dimensions 24 x 48 24 x 48 24 x 48 36 x 72 36 x 72 48 x 96 48 x 96 48 x 96 48 x 96 48 x 96 48 x 96 48 x 96 48 x 96 48 x 96 48 x 48 Sondergröße
Measuring input
normalized signal ● ● ● ● ● ● ● ● ● ● ●
Measuring input temperature
(Pt100 / Pt1000) ● ● ● ● ● ● ● ●
Simulator
Measuring input
Voltage / current ● ●
Measuring input PH / LF ●
Device information:
79
for additional accessories p.r.t. page 102 - 103
µP-DISPLAY WITH FREELY ADJUSTABLE SCALE
Handheld instrument
FRONT
24 x 48 HIGHLIGHTS:
TIVITY,
X, OXYGEN, CONDUC
MOISTURE, PH, REDO PR ESSURE, DISTANCE,
GAS, TEMP ER AT UR E,
FILL LEVEL, POWER
VO LU TIO NA L SP EE D, FLOW RATE, FLOW,
RE
Logger / EASYBus
Imax: 100 mA
Accuracy: < 0.2% FS ±1 digit (at 25 °C)
Pmax: 1.2 W (for GIA 0420 N - ex) or 0.95 W (for GIA 010 N - ex)
Temperature drift: < 100 ppm / K
Measuring rate: approx. 5 measurements / s max. effective internal capacitance:
Filter: adjustable: 0.1 ... 2.0; off Ci = 13 nF (for GIA 0420 ...) or 26 nF (for GIA 010 ...)
Storage: min- / max-value memory selectable via button additionally for the switching output: Ci = 4.5 nF
max. effective internal inductance: negligible small
Switching output: electrically isolated open collector
Please keep in mind for the circuit of the optionally available switching output
Switching capacity: 28 V DC / 50 mA
that the wiring has to be done from the same intrinsically safe circuit as the
Working temperature: -20 ... +50 °C measuring signal!
Storage temperature: -20 ... +70 °C
Electric connection: GIA 0420 N ..:
2 x 2-pin screw-type/plug-in terminal
max. terminal range up to 1.5 mm²
Simulator
80
further information on www.greisinger.de
Display / Controller
Handheld instrument
FRONT FRONT
24 x 48 24 x 48
GTH 2448/1
Display / Controller
Product-ID: 600083
Display for temperature (NiCr-Ni)
GIA 2448
Product-ID: 600090 (standard model) GTH 2448/2
Display for Standard Signals (for self-adjustment) Product-ID: 600084
Display for temperature (Pt100)
GIA 2448 WE 1)
Display for Standard Signals (settings and calibrations by our works) GTH 2448/3
Product-ID: 600085
1)
Please specify as follows upon order: Input signal, scaling (lower and upper Display for temperature (Pt100)
limits), decimal point and supply voltage. (Order to read e.g. GIA 2448 WE:
4-20 mA, 4 mA=-50.0, 20 mA = 100.0, 12 VDC) GTH 2448/4
Product-ID: 600086
Logger / EASYBus
Specifications: Display for temperature (Pt1000)
Measuring input: 0-20 V, 0-10 V, 0-2 V, 0-1 V, 0-200 mV, 0-20 mA
and 4-20 mA (select via soldering jumpers) GTH 2448/5
Display range: -1999 ... +1999 digit Product-ID: 600087
(adjustable via soldering jumpers and potentiometer) Display for temperature (Pt1000)
Decimal point: any position by means of soldering jumpers Specifications:
(soldering jumpers accessible after removal of front panel) Measuring input, Resolution:
Accuracy: ±0.2 % ±1 digit (at nominal temperature = 25 °C) GTH 2448/1: -50 ... +1150 °C (NiCr-Ni)
Scan rate: approx. 3 measurements / s GTH 2448/2: -200 ... + 650 °C (Pt100, 2-wire), 1 °C
Display: 3½-digit, red 10 mm high LED display GTH 2448/3: -60.0 ... +199.9 °C (Pt100, 2-wire), 0.1 °C
Working temperature: 0 ... 50 °C (permissible ambient temperature) GTH 2448/4: -200 ... + 650 °C (Pt1000, 2-wire), 1 °C
Relative humidity: 5 ... 95 % RH (non-condensing) GTH 2448/5: -60.0 ... +199.9 °C (Pt1000, 2-wire), 0.1 °C
Transmitter
Storage temperature: -20 ... +70 °C Accuracy: (at nominal temperature = 25 °C)
Voltage supply: 8 - 20 V DC or 18 - 29 V DC (standard) NiCr-Ni: ±1 % ±1 digit (from -20 ...+550 °C and 920 ...1150 °C)
(set via soldering jumper) ±1.5 % ±1 digit (from 550 ... 920 °C)
Current supply: max. 20 mA Pt100, Pt1000: ±0.5 °C ±1 digit or ±1 °C ±1 digit
Housing: glass fi bre reinforced Noryl, front panel PC Offset compensation: The zero point offset of the sensor (e.g. due to long cables)
Dimensions: 24 x 48 mm (H x W) (front frame) (only for Pt100 and can be compensated for by means of the spindle trimmer on
Mounting depth: approx. 65 mm (incl. screw-type/plug-in terminal) Pt1000) the backside of the device.
Panel mounting: with VA-spring clamp. Display: 3½-digit, red 10 mm high LED display
allowed panel thicknesses from 1 ... approx. 10 mm Scan rate: approx. 3 measurements / s
Panel cut-out: 21,7+0.5 x 45+0.5 mm (H x W). Working temperature: 0 ... 50 °C (permissible ambient temperature)
Temperature probe
Connection terminal: 4-pin screw-type/plug-in terminal for wire cross sections Relative humidity: 5 ... 95 % RH (non-condensing)
from 0.14 ... 1.5 mm² Storage temperature: -20 ... +70 °C
Noise immunity (EMV): meets EN50081-1 and EN50082-2 requirements, Voltage supply: 8 - 20 V DC or 18 - 29 V DC (standard)
additional fault: <1 % (set via soldering jumper)
Protection class: front side IP54 (with optional O-rings IP65). Current supply: max. 20 mA
Scope of supply: Device, manual Housing: glass fi bre reinforced Noryl, front panel PC
Option: Dimensions: 24 x 48 mm (H x W) (front frame)
VAC Mounting depth: approx. 65 mm (incl. screw-type/plug-in terminal)
voltage supply 8-20 V AC or 18 - 29 V AC set via soldering jumper Panel mounting: with VA-spring clamp.
G24 allowed panel thicknesses from 1 ... approx. 10 mm
22-27 V DC, electrically isolated) Panel cut-out: 21,7+0.5 x 45+0.5 mm (H x W).
Connection terminal: 4-pin screw-type/plug-in terminal
Accessories and spare parts:
Simulator
for wire cross sections from 0.14 ... 1.5 mm²
GNG 220/2-12V
Protection rating: front side IP54
Product-ID: 600305
power supply for GIA 2448 and GTH 2448 Scope of supply: Device, manual
(Input: 230 VAC; output: 2 x 12 VDC regulated, 30 mA each)
System solution - complete packages:
GNG 12 / 24
Product-ID: 600276
power supply (Input: 12 VDC; output: 24 VDC electrically isolated)
KFZ 2000
Product-ID: 603241
GNG 24 / 24 Exhaust gas temperature set for measurement of exhaust gas temperatures
Product-ID: 600277
up to 1000 °C in motor vehicles (e.g. motorsports). The set consists of:
Alarm / Protection, Level
power supply (Input: 24 VDC; output: 24 VDC electrically isolated)
GTH 2448/1 12 V DC:
Product-ID: 601017
for additional accessories, transmitter, probes p.r.t. chapters transmitter and NiCr-Ni thermometer with additional over-voltage protection.
temperature probe GTF 101-5-30-0150-L03-S:
Product-ID: 601317
temperature probe with jacket material: Nimonic 75 (view p.r.t. page 147)
Cable length = 3 m (extended cable against upcharge available)
GKV 4:
Product-ID: 602891
clamping ring screw connection (p.r.t. p. 158)
81
for additional accessories p.r.t. page 102 - 103
UNIVERSAL DISPLAY AND REGULATING DEVICE
Handheld instrument
HIGHLIGHTS:
GIA 20 EB
Product-ID: 601832 (standard model)
Universal display and regulating device
Specifications: Power consumption: max. 30 mA (without outputs)
Measuring input: universal input for Nominal temperature: 25 °C
Normalized signal: 4-20 mA, 0-20 mA, 0-1 V, 0-2 V, 0-10 V, 0-50 mV Operating temperature: -20 ... +50 °C
Logger / EASYBus
Serial interface: Displaying and controlling from values coming via the serial
interface. Accessories and spare parts:
Accuracy: (at nominal temperature = 25 °C) FS3T
Product-ID: 603215
Normalized signal: < 0.2 % FS ±1 digit (at 0-50 mV: < 0.3 % FS ±1 digit)
Frontpanel with 3 push-buttons for comfortable confi guration, for adjustments at variable
Resistance < 0.5 % FS ±1 digit switching points, calling of min- and max-values etc.
thermometer:
GNR 10
Thermocouples: < 0.3 % FS ±1 digit (at type S: < 0.5 % FS ±1 digit) Product-ID: 603680
Point of comparison: ± 1 °C Power supply and relay module for one GIA20EB (p.r.t. page 103)
(Input: 230VAC, Power supply for device + transducer, 2 relay outputs)
Frequency, rotational < 0.1 % FS ±1 digit
speed, counter: Temperature probes p.r.t. page 145 - 159
Outputs: 2 switching outputs, not electrically isolated Transducer p.r.t. page 113 - 144
Switching behavior: Low-Side, High-Side or Push-Pull (selectable)
Simulator
82
further information on www.greisinger.de
Display / Controller
Handheld instrument
HIGHLIGHTS:
• frequency
PLAY
CONFIGURABLE AS DIS
R • NTC
OR CONTROLLE
Display / Controller
NS)
(5 SWITCHING FUNCTIO GIR 230 DIF-PT...
Product-ID: 600982
GIR 230 NS Difference controller with 2 measuring inputs for Pt1000
Product-ID: 600972 GIR 230 DIF-NT...
GIR 230 Pt Product-ID: 600984
Difference controller with 2 measuring inputs for NTC
Product-ID: 600976
Logger / EASYBus
Version GIR 230 Pt1000 / DIF, GIR 230 NTC / DIF:
Product-ID: 600970 Measuring inputs: 2 x Pt1000 (2-wire) or 2 x NTC
Transmitter
Measuring input: Pt100 (3-wire), Pt1000 (2-wire) Accuracy: < 0.2 % FS ±1 digit (at nominal temperature = 25 °C)
Measuring ranges, resolution: Measuring rate: approx. 100 measurings / s
Pt100: -200 ... +850 °C (1°) or -50.0 ... +200.0 °C (0.1°)
Specification:
Pt1000: -200 ... +850 °C
Relay output: 2 (1) closing contacts (GIR 230 NTC: 1 relay output),
Accuracy: < 0.5 % FS ±1 digit (at nominal temperature = 25 °C) 230 V~ switching, switching power: 5 A, 230 VAC
Messrate: approx. 4 measurings / s Alarm output: NPN, open collector, switching power: 30 mA, max. 28 V
Version GIR 230 TC (thermo couple): Controller states: 2-point, 3-point*, 2-point with alarm, min / max alarm to
1 output, min / max alarm to 2 outputs*
Measuring input: types J, K, N, S, T and 0-50 mV (* = not available at GIR 230 NTC)
Temperature probe
Measuring ranges, Type J: -170 ... +950 °C, Type K: -270 ... +1350 °C, Switching points, freely selectable
resolution: Type N: -270 ... +1300 °C, Type S: -50 ... +1750 °C, hysteresis, alarm points:
Type T: -270 ... +400 °C
Display: approx. 10 mm high, 4-digit red LED-display
Accuracy: < 0.3 % FS ±1 digit (type S: < 0.5 % FS ±1 digit) (at 25 °C)
Operating conditions: -20 ... +50 °C, 0 ... 80 % RH (non condensing)
Point of comparison: ± 1 °C
Power supply: 230 V, 50 / 60 Hz, approx. 2 VA
Measuring rate: approx. 4 measurings / s
Optional: SA1: GIR with power supply 12 - 28 V DC
Version GIR 230 FR (frequency): Outputs: 2 (1) relay outputs, +Ub switching
Measuring input: frequency Housing: glass fi bre reinforced Noryl, front panel PC
Display range: -1999 ... 9999 digit, freely scaleable Dimensions: 24 x 48 mm (front frame)
Accuracy: < 0.2 % FS ±1 digit (at nominal temperature = 25 °C) Mounting depth: approx. 65 mm (incl. screw-type/plug-in terminal)
Frequency measuring: 0.000 Hz ... 10 kHz Panel mounting: with VA-spring clamp
Rotational speed: 0.000 U/min ... 9999 U/min, selectable prescaler (1-1000) Allowed panel thicknesses: from 1 ... approx. 10 mm
Simulator
GTF 230 S
Product-ID: 603014
Options:
NTC-temperature probe, -40 ... +120 °C, sensor sleeve made of stainless steel, SA1
Ø 5 x 50 mm, approx. 1 m silicone-cable power supply 12 - 28 V DC, Outputs: 2 (1) relay outputs, +Ub switching
GTF 230 S-L03 SA2
Product-ID: 605910 power supply 12-24 V DC
see above, approx. 3 m silicone cable SA3
GTF 230 S-L05 power supply 12 V DC, electrically isolated
Product-ID: 604620 SA4
see above, approx. 5 m silicone cable power supply 24 V DC, electrically isolated
83
for additional accessories p.r.t. page 102 - 103
UNIVERSAL DISPLAYING AND CONTROLLING DEVICE
Handheld instrument
HIGHLIGHTS:
GIR 300
Logger / EASYBus
Frequency: 0.000 Hz ... 10 kHz, display freely scalable
Rotational speed: 0.000 U/min ... 9999 U/min, selectable prescaler: 1-1000
Accessories and spare parts:
APG-7
Up- / down- counter: The counter reading is stored also in power-down state.
Product-ID: 606825
0 ... 9999 (10 million with prescaler),
Housing for surface mounting incl. seal GGD4896
pulse frequency: ≤ 10 kHz, selectable prescaler: 1-1000
EAK 36
Serial interface: Display and control functions with values obtained via serial
Product-ID: 603227
interface
Unit stickers (black with white text) for 36 different units for lettering of display devices.
Accuracy: (at nominal temperature = 25 °C)
Standard signals: < 0.2 % FS ±1 digit (at 0-50 mV: < 0.3 % FS ±1 digit)
Resistance < 0.5 % FS ±1 digit
thermometer:
Thermocouples: < 0.3 % FS ±1 digit (for type S: < 0.5 % FS ±1 digit)
Point of comparison ± 1 °C
Simulator
accuracy:
Frequency, rotational < 0.1 % FS ±1 digit
speed, counter:
Outputs: 2 volt-free relay switching outputs
relay 1: normally-open contact
relay 2: normally-closed contact
Switching functions: 2-point, 3-point, 2-point with alarm, combined min-/max- alarm
with 1 output, separate min-/max- alarm with 2 outputs
Switching points, freely selectable
Alarm / Protection, Level
switching hysteresis:
Response time: ≤ 20 ms for standard signals
≤ 0.5 s for temperature and frequency
Display: approx. 13 mm high, 4-digit red LED display
Interface: serial interface, electrically isolated, compatible to EASYBus
Miscellaneous: continuous self-diagnostics, digital fi lter function, measuring
range limitation
84
further information on www.greisinger.de
Display / Controller
Handheld instrument
NEW !
FRONT
36 x 72 HIGHLIGHTS:
• 6-digit display
E.A.S.Y.Bus - Modul
• Assembly, dismantling, sum and difference counter
FUNCTIONS:
• 2 integrated switching outputs (galvanically isolated)
MIN
MAX • Configurable as display or controller (5 switching functions)
Display / Controller
• Extensive self-monitoring and diagnostic system
GIR 360
Logger / EASYBus
Product-ID: 607953
Freely selectable universal counter and frequency meter
Specifications: Current consumption: max. 70 mA
Inputs: Nominal temperature: 25 °C
Input 1: frequency, rotational speed, counter input A Working temperature: -20 ... +50 °C
Input voltage: 0 ... 5 V (0 ... 28 V with dropping resistor) Relative humidity: 0 ... 80 % r.F. (non condensing)
Input level: Low < 0.5 V; High > 2.2 V Storage temperature: -30 ... +70 °C
NPN: pullup resistor 7 kohms to 3.3 V Housing:
PNP: pulldown resistor 7 kohms against GND Dimensions: 36 x 72 mm (front frame)
Min. pulse width: 50 us Installation depth: approx. 75 mm (incl. screw-type/plug-in terminals)
Input 2: count input B, Gate, direction Panel mounting: with fi xing clamps
Transmitter
Input voltage: 0 ... 5 V (0 ... 28 V with dropping resistor) panel cutout: 32.0+0.5 x 68.5+0.5 mm (H x W)
Temperature probe
Frequency: 0 ... 10 kHz APG-7
Product-ID: 606825
Speed: max. 10000 U/min, switchable prescaler: 1 ... 1000
Housing for surface mounting incl. seal GGD4896
Counter: -2.147.483.647 … 2.147.483.646
EAK 36
Display area: Product-ID: 603227
Frequency / Speed: -1999 ... 9999 digit, decimal point freely selectable Unit stickers (black with white text)
for 36 different units for lettering
Counter: -1999999 ... 999999 digit, decimal point freely selectable of display devices.
Functions: Frequency measurement
Speed measurement,
Up counter, down counter
Up / down counter with direction input
Totalizer A + B,
Difference counter A-B, phase discriminator
Display: approx. 10 mm high, 6-digit red LED display
Simulator
Outputs: 2 volt-free relay switching outputs
relay 1: normally-open contact
relay 2: normally-closed contact
Switching functions: 2-point, 3-point, 2-point with alarm, combined min-/max- alarm
with 1 output, separate min-/max- alarm with 2 outputs
Switching points, freely selectable
switching hysteresis:
Interface: serial interface, electrically isolated, compatible to EASYBus
Miscellaneous: continuous self-diagnostics, digital fi lter function, measuring
Alarm / Protection, Level
range limitation
Supply voltage: 9 ... 28 V DC (standard)
Optional: G24: 22 ... 27 V DC, electrically isolated
85
for additional accessories p.r.t. page 102 - 103
UNIVERSAL DISPLAYING AND REGULATING DEVICE
Handheld instrument
HIGHLIGHTS:
MAX
(EBW 3 required)
Product-ID: 600951 (Standard model) 0 ... 20 mA, 4 ... 20 mA: -1999 ... +9999 digit, < 0.2 % FS ±1 digit
Universal displaying and regulating device with PID-control mode scale freely adjustable
Anwendungen: 0 ... 50 mV: -1999 ... +9999 digit, < 0.3 % FS ±1 digit
• process regulating scale freely adjustable
• temperature controller Frequency
• pressure monitoring TTL-signal: 0.000 Hz ... 10 kHz, < 0.1 % FS ±1 digit
• rotation speed display scale freely adjustable
• fl ow counter, etc.
Switching contact NPN: 0.000 Hz ... 3 kHz, < 0.1 % FS ±1 digit
General: scale freely adjustable
Transmitter
ters are automatically saved, so that all data will be maintained even in case of a power pulse frequency: max. 10 000
blackout. Imp./s at TTL
Among others most of the GREISINGER transmitters, rpm sensors and fl ow rate sensors
Serial interface: displaying and controlling from values coming via the serial
can be connected directly to the integrated transmitter power supply (24 VDC/22 mA) of
interface
the controller.
If the device is used as a thermocouple or resistance thermometer, the measuring value Outputs:
can be alternatively displayed in °C or °F. By means of an offset correction the measured Please note: Not all options are available for both device types and not all options can be
value can be scaled i.e. to the resistivity of the wires. The current and voltage inputs can combined with each other. Please see therefore the matrix.
be arbitrarily scaled in the range of -1999 ... +9999. Output 1 R1: voltage free relay output (standard) normally-open contact,
The GIR 2002 has a serial, bus-compatible interface by default, by which a comfortable (standard version) switching power: 5 A (ohmic load), 250 VAC
adjustment of the parameters as well as recording of measured values is possible. With
the optionally available Windows library EASYBUS.dll up to 240 devices can be integrated Optional: H1: control output for semiconductor relay (6 VDC / 15 mA)
into own programs (i.e. LabView). AAG..1: freely scalable analog output 0(4)-20 mA or 0-10 V
ST..1: continuous output 0(4)-20 mA or 0-10 V
Specifications: Output 2 R2: voltage free relay output (standard) change-over contact,
Measuring input Measuring / display ranges: Accuracy (standard version) switching power: 10 A (ohmic load), 250 VAC
Simulator
(at nominal temperature): Optional: H2: control output for semiconductor relay (6 VDC / 15 mA)
Thermocouples (4 measurings / s) Output 3: (not available at standard device type)
FeCu-Ni: -70.0 ... +300.0 °C or < 0.3 % FS ±1 digit * Optional: R3: voltage free relay output (chance-over contact)
(type J, IEC 584) -170 ... +950 °C switching power: 1 A / 40 VAC or 30 VDC
NiCr-Ni: -70.0 ... +250.0 °C or < 0.3 % FS ±1 digit * H3: control output for semiconductor relay
(type K, IEC 584) -270 ... +1372 °C (14 VDC / 15 mA)
N3: electrical isolated NPN-switching contact
NiCrSi-NiSi: -100.0 ... +300.0 °C or < 0.3 % FS ±1 digit * (max. 1 A / 30 VDC)
(type N, IEC 584) -270 ... +1350 °C AA3: freely scalable analog output 0(4)-20 mA or 0-10 V
Pt10Rh-Pt: -50 ... +1750 °C < 0.5 % FS ±1 digit * SA3: continuous output 0(4)-20 mA
Alarm / Protection, Level
86
further information on www.greisinger.de
Display / Controller
Handheld instrument
Interface: serial interface, electrical isolated, EASYBus compatible GIR 2002 GIR 2002 PID
Outputs
Power supply for sensor: 24 V DC ±5 %, 22 mA (for DC-supply 18 V DC) out 1 out 2 out 3 out 1 out 2 out 3
Miscellaneous: permanent self-monitoring, digital filter function, measuring Standard type: normally- chance- -- normally- chance- --
range boundary (limit) open over open over
Voltage supply: 230 V AC, 50/60 Hz (standard) contact contact contact contact
optional: 012D: voltage supply: 12 VDC (11-14 V) 1) available output options
024D: voltage supply: 24 VDC (22-27 V) 1) output 1 =
024A: voltage supply: 24 VAC ±5 % ● ●
control output H1:
115A: voltage supply: 115 VAC ±5 % output 2 =
Power consumption: approx. 6 VA ● ●
control output H2:
Operating conditions: -20 ... +50 °C, 0 ... 80 % RH (non condensing) output 3 =
Display / Controller
● ●
Housing: standard rack type housing 48 x 96 mm (front frame) relay (chance-over contact) R3:
installation depth: approx. 115 mm (incl. screw-type/plug-in output 3 =
terminals) ● ●
control output H3:
Panel mounting: with fixing clamps output 3 =
panel cutout: 43.0+0.5 x 90.5+0.5 mm (H x W) ● ●
NPN-switching output N3:
Electrical connection: via screw-type/plug-in terminals output 1 =
cable diameters from 0.14 ... 1.5 mm2. ●
analog output 0(4) - 20 mA AA1: no out3
Protection class: front side IP54, with optional sealing IP65 possible
output 1 =
●
Electromagnetic EN61326 (appendix A, class B) analog output 0 - 10 V AV1:
immunity (EMC): output 3 =
● ●
Scope of supply: device, fixing clamps, manual analog output 0(4) - 20 mA AA3:
output 3 =
● ●
Logger / EASYBus
Accessories and spare parts: analog output 0 - 10 V AV3:
GGD4896 output 1 =
Product-ID: 603042 ●
continuous output 0(4) - 20 mA SA1: no out3
additional sealing for panel mounting IP65 possible
output 1 =
EAK 36 ●
continuous output 0 - 10 V SV1:
Product-ID: 603227
output 3 =
Unit stickers (black with white text) for 36 different units for lettering of display devices ●
continuous output 0(4) - 20 mA SA3:
(p.r.t. page 89)
output 3 =
Temperature probes p.r.t. page 145 - 159 ●
continuous output 0 - 10 V SV3:
for other accessories p.r.t. page 76, 112
Transmitter
Ordering code: Ordering code:
GIR2002- 1 - 2 - 3 - 4 - 5 - 6 GIR2002PID- 1 - 2 - 3 - 4 - 5 - 6
Greisinger Greisinger
Temperature probe
230A 230 V AC 230A 230 V AC (Standard)
012D 12V DC 012D 12V DC
012DA 12V DC for analog output or NPN or REL3 or HLR3
012DA 12V DC for analog output or NPN or REL3 or HLR3
024A 24V AC
024A 24V AC
024D 24V DC
024D 24V DC 024DA 24V DC for Stetig / Analog; NPN
024DA 24V DC 115A 115 V AC
115A 115 V AC 2. Output 1
2. Output 1 -R1 Relay, NO switch (Standard)
-R1 Relay, NO switch -H1 Solid-State-Relais
-SA1 Continuous output 0(4)..20 mA, no out3 possible
-H1 Solid-State-Relais
-SV1 Continuous output 0 to 10V, no out3 possible
-AA1 Analog output 0(4)..20mA 3. Output 2
Simulator
87
for additional accessories p.r.t. page 102 - 103
2-CHANNEL DIFFERENCE CONTROLLER TEMPERATURE REGULATOR
Handheld instrument
FRONT FRONT
48 x 96 48 x 96
E.A.S.Y.Bus - Modul
FUNCTIONS:
MIN
MAX
Display / Controller
MEASURING INPUT
GIR 2002 NS / DIF - 020 GIR 2000 Pt FOR PT100 (3-WIRE)
Product-ID: 604871 (Standard model) Product-ID: 601701 (Standard model)
2-channel difference controller, input signal (2x) 0-20 mA Temperature regulator complete with sensor
Specifications:
Output: voltage free relays output, change-over-contact,
Transmitter
EBW 3 connections), Cable insert: screw connections M12 x 1.5 and M16 x 1.5
Product-ID: 601137
additional suitable temperature probes p.r.t. page 145-159
Interface converter for connection of one EASYBus-module to the USB interface of your
PC. (Power supply: from the USB port)
Standard variant:
EBS 20M
GIR2000-PT-024D
Product-ID: 601158
Product-ID: 603491
20 channel measurement data acquisition software
GIR 2000 PT with voltage supply 24 V DC (22-27 V)
GIA 20 EB / GIR 2002 - Configuration Software
GIR2000-PT-OF-024D
Software for easy confi guration of the types GIA 20 EB, GIR 2002, GIR 2002 PID,
Product-ID: 602280
download under www.greisinger.de
GIR 2000 PT with voltage supply 24 V DC (22-27 V)
88
further information on www.greisinger.de
Display / Controller
Handheld instrument
HIGHLIGHTS:
Display / Controller
• Limit functions, digital filter, min-/max value memory
AY
TEMPERATURE DISPL
PRES SU RE CONTROL
METER, ETC.
TACHOMETER, FLOW
GIA 2000
Product-ID: 600963 (Standard version)
Logger / EASYBus
Universal Displaying Device
Specifications: Relative humidity: 0 ... 80 % RH (non condensing)
Measuring input: universal input (freely adjustable) for Storage temperature: -30 ... +70 °C
Normalized signal: 4-20 mA, 0-20 mA, 0-1 V, 0-2 V, 0-10 V, 0-50 mV Housing: standard rack type housing 48 x 96 mm (front frame)
Resistance Pt100 (3-wire), Pt1000 (2-wire) Installation depth: approx. 115 mm (incl. screw-type/plug-in terminals)
thermometer: Panel mounting: with fi xing clamps
Thermocouples: types J, K, N, S, T panel cutout: 43.0+0,5 x 90.5+0,5 mm (H x W)
Frequency: TTL-signal, switching contact Electrical connection: via screw-type/plug-in terminals
Flow, Rotational speed: TTL-signal, switching contact cable diameters from 0.14 ... 1.5 mm2.
Transmitter
frequency) or approx. 4 measurings / s (for temperature) Scope of supply: device, manual
Temperature probe
recommended range: ≤ 2000 Digit GIA 2000 with analog output 0 - 20 mA, 4 - 20 mA (changeable)
Frequency: 0.000 Hz ... 10 kHz, display freely scalable GIA 2000-AV
Rotational speed: 0.000 U/min ... 9999 U/min, selectable prescaler: 1-1000 Product-ID: 602725
GIA 2000 with analog output 0 - 10 V
Flow: 0 ... 9999 l/s, 0 ... 9999 l/min, 0 ... 9999 l/h
Counter up/down: counter value remains on power loss Accessories and spare parts:
0 ... 9999 (10 mio. with prescaler), pulse frequency: ≤ 10 kHz
GGD 4896
Serial interface: Displaying and controlling from values coming via the serial Product-ID: 603042
interface. additional sealing for panel mounting IP65
Accuracy: (at nominal temperature = 25 °C) EAK 36
- Normalized signal: < 0.2 % FS ±1 digit (at 0-50 mV: < 0.3 % FS ±1 digit) Product-ID: 603227
Unit stickers (black with white text)
- Resistance < 0.3 % FS ±1 digit for 36 different units for lettering
thermometer: of display devices.
- Thermocouples: < 0.3 % FS ±1 digit (at type S: < 0.5 % FS ±1 digit)
Simulator
Miscellaneous: permanent self-monitoring, digital fi lter function, measuring
range boundary (limit) Temperature probes p.r.t. page 145 - 159
89
for additional accessories p.r.t. page 102 - 103
TANK DISPLAY
Handheld instrument
NEW !
HIGHLIGHTS:
TA 9648
Tank Display
Application: Dimensions:
The tank display TA 9648 offers content measurement of tanks with no linear connection
between level and content. Measurement will be realized by hydrostatic pressure or
Logger / EASYBus
distance sensors. The device offers the possibility to connect a level sensor. Reaching a
certain level, the displayed value will be corrected automatically to the value according to
the position of the installed sensor.
Specifications:
Power supply:
Supply voltage: 230 V AC ±10 %; 115 V AC ±10 %,
24 V AC ±10 % or 24 V DC ±15 %
Power consumption: max. 3.5 VA, with analog output 5 VA
Working temperature: -10 ... +55 °C
CE-conformity: EN 55022, EN 60555, IEC 61000-4-3/4/5/11/13
Input:
Current: 0/4 ... 20 mA; Ri = 10 Ω
Transmitter
overload 2-times; 4-times for max. 5 s
Voltage: 0/2 ... 10 V DC; Ri = 100 kΩ
Ordering code:
overload max. 100 V
Accuracy: < 0.1 % ± 2 Digit
TA9648- 1 - 2 - 3 - 4 - 5 - 6 - 7
Transmitter supply: U0 approx. 24 V; Ri approx. 150 Ω; max. 50 mA
Display: LED rot, 14.2 mm
Ordering code:
Indicating range: 999999 Digit with leading zero suppression 1. Terminal strip A
Parameter display: LED 2 digit red, 7 mm (parameter - and output indicating) 1 inputs 0/4..20 mA, 1 input for level correction,
Output: Integrated, transmitter supply 24 V max. 50 mA
Temperature probe
90
further information on www.greisinger.de
Display / Controller
UNIVERSAL COUNTER
Handheld instrument
NEW !
FRONT HIGHLIGHTS:
48 x 96
• Counting, length measurement, metering, positioning
Display / Controller
UZ 9648
Universal Counter
Application: Connection:
The universal counter UZ 9648 has been designed for fi eld application in process control
and automation. Parameters for operation mode can be programmed. The counter can
Logger / EASYBus
be used wherever quantity processes should be measured, displayed and monitored.
Specifications:
Power supply:
Supply voltage: 230 V AC ±10 %; 115 V AC ±10 %;
24 V AC ±10 % or 24 V DC ±15 %
Power consumption: max. 3.5 VA, with analog output 5 VA
Working temperature: -10 ... +55 °C
CE- conformity: EN 55022, EN 60555, IEC 61000-4-3/4/5/11/13
Input:
PNP sensor: Ri = 6.3 kΩ
Dimensions:
level: < 4 V low; > 8.5 V high;
hysteresis > 2.5 V; max. 35 V DC
Transmitter
Namur sensor: Ri approx. 1 kΩ (< 4 mA)
level: < 1 mA low; >2.2 mA high;
hysteresis > 0.5 mA; max. 35 V DC
Pulse frequency: input A or B = 15 kHz,
A and B together = 6 kHz,
contact = 30 Hz debounced,
2-channel rotary encoder = 8 kHz
Counting loss: 100 μs at reset;
20 ms changing of preselect value
Min. pulse width: electronic 50 μs, contact 5 ms
Temperature probe
External reset: reset impulse ≥ 10 ms
Transmitter supply: 8 V DC (Namur), 24 V DC (PNP), Ri approx. 150 Ω, max. 50
mA (25 mA with 4 relay outputs)
Display LED red, 14.2 mm
Indicating range: -99999 ... +999999 Digit with leading zero suppression Ordering code:
Additional display: LED 2-digit red, 7 mm
(parameter - and output indicator) UZ9648- 1 - 2 - 3 - 4 - 5 - 6 - 7
Output:
Relay: SPDT < 250 V AC < 250 VA < 2 A, Ordering code:
< 300 V DC < 50 W < 2 A 1. Terminal strip A
Transistor: max. 35 V AC/DC, 100 mA, 1 2 confi gurable count inputs, display conversion, wide
with short circuit protection range of count functions, integrated transmitter supply
Analog output: 0/4 ... 20 mA burden ≤ 500 Ω; 0/2 ... 10 V, 24 V max. 50 mA
Simulator
0 230 V AC ±10 % 50-60 Hz
1 115 V AC ±10 % 50-60 Hz
4 24 V AC ±10 % 50-60 Hz
5 24 V DC ±15 %
5. Options
00 without option
6. Unit (appears in the unit fi eld)
7. Additional text placed above the display (3 x 90 mm H x W)
91
for additional accessories p.r.t. page 102 - 103
PH AND ORP PANELMETER
Handheld instrument
HIGHLGHTS:
NEW !
• Analog output 0/4 ... 20 mA or 0/2 ... 10 V for pH / ORP
pH 9648
pH and ORP panelmeter
Application: Connection:
The pH and ORP Panelmeter pH 9648 is suitable for pH and ORP measurement in food
technology, chemistry within pharmaceutical and sewage-water technology. The pH 9648
operates with all common pH- and ORP electrodes. It is recommended to connect the
Impedance-Converter pH40 for cable length > 5 m.
Specifications:
Logger / EASYBus
Power supply:
Supply voltage: 230 V AC ±10 %; 115 V AC ±10 %;
24 V AC ±10 % or 24 V DC ±15 %
Power consumption: max. 3.5 VA, with analog output 5 VA
Working temperature: -10 ... +55 °C
CE- conformity: EN 55022, EN 60555, IEC 61000-4-3/4/5/11/13
Input pH/ORP
Transmitter supply
Measuring range: 1.00 ... +15.00 pH or -1500 ... +1500 mV
Ri: > 1012 Ω Dimensions:
Input current: < 10-12
A
Accuracy: 0.2 % measuring value, ±2 Digit
Transmitter
pH setup: electrode zero point 4.00 ... 10.00 pH
slope 40.0 ... 70.0 mV/pH
ORP setup: ± 200 mV
Calibration mode: - 1- or 2-point-calibration
Buffer selection possible:
- Schott
- WTW
- Ingold (Mettler Toledo)
- Puffer acc. to DIN 19266
- or manual buffer input
- Data entering for zero point and slope
- ORP offset
Temperature probe
Temperature:
Sensor: Pt100 or Pt1000 (2- or 3-wire connection)
Unit: programmable °C, °F
Measuring range: -40.0 ... +160.0 °C (-40.0 ... +320.0 °F) Ordering code:
Accuracy: ± 0.1 %, ±1Digit
Transmitter supply: 24 V DC, Ri approx. 150 Ω, pH9648- 1 - 2 - 3 - 4 - 5 - 6 - 7
max. 50 mA (25 mA with 4 relay outputs)
Display: LED red, 14.2 mm Ordering code:
Parameter display: LED 2-digit red, 7 mm 1. Terminal strip A
(Parameter - and output indicator) 13 input pH / ORP electrode,
Output: temperature compensation via Pt100 / Pt1000
2. Terminal strip B
Relay SPDT: < 250 V AC < 250 VA < 2 A,
00 not installed
Simulator
< 300 V DC <50 W < 2 A
2R 2 relay outputs
Transistor: < 35 V AC/DC, max.100 mA,
short-circuit-proof 2T 2 electronic outputs
3. Terminal strip C
Analog output active: 0/4 ... 20 mA burden ≤500 Ω; 0/2 ... 10 V burden > 500 Ω,
isolated, automatic output changing (burden dependent) 00 not installed
2R 2 relay outputs
Analog output passive: 4 ... 20 mA, ext. burden = RA[Ω]≤ (UB-5 V) ÷ 0.02 A;
supply voltage 5 ... 30 V DC 2T 2 electronic outputs
AO analog output 0/4..20 mA, 0/2..10 V DC
Accuracy: 0.1 %
2A 2 analog outputs 4..20 mA passive
Housing: panel mounting DIN 96 x 48 mm, material PA6-GF; UL94V-0
4. Terminal strip B supply voltage
Alarm / Protection, Level
92
further information on www.greisinger.de
Display / Controller
CONDUCTIVITY METER
Handheld instrument
HIGHLIGHTS:
NEW !
• Input for 2- or 4-electrode cells
FRONT
48 x 96 • Temperature compensation via Pt100
Display / Controller
LF 9648
Conductivity Meter
Application: Dimensions:
The Conductivity Meter LF9648 has been designed for the measurement of conductivity,
as a degree of the purity or concentration of a liquid. In connection with 4-electrode-
conductivity cells a high accuracy and insensitivity of contamination can be achieved. A
further advantage is a broad range of application with only one cell. Only for measure-
ment in ultra-pure water a special 2-electrode conductivity cell must be used.
Logger / EASYBus
Specifications:
Power supply:
Supply voltage: 230 V AC ± 10 %; 115 V AC ± 10 %;
24 V AC ± 10 % or 24 V DC ± 15 %
Power consumption: max. 3.5 VA, 5 VA with analog output
Working temperature: -10 ... +55 °C
CE-conformity: EN55022, EN60555, IEC61000-4-3/4/5/11/13
Inputs
MR conductivity: 0..2.000(0) μS/cm up to 0..2000 / 200(0) mS/cm (at 25 °C)
- Cell constant: 0.080 ... 9.999
- Accuracy: 0.5 % of the measuring value, ±2 Digit Ordering code:
Transmitter
- Temperature non linear for ultra pure water and natural water or linear
compensation: programmable from 0.000 ... 9.999 % / K LF9648- 1 - 2 - 3 - 4 - 5 - 6 - 7
MR temperature: -50.0 ... +200.0 °C; Sensor Pt100 or Pt1000
- Accuracy: ±0.2 °C Ordering code:
Display: LED red, 14.2 mm 1. Terminal strip A
Indicating range: 2000(0) Digit with leading zero suppression 1 input for 2- or 4-electrode-cells, temperature
compensation via Pt100
Parameter display: LED 2-digit red, 7 mm (parameter - and output indicator)
3 as 1, but temperature compensation via Pt1000
Outputs 2. Terminal strip B
Relay: SPDT < 250 V AC < 250 VA < 2 A, 00 not installed
< 300 V DC < 50 W < 2 A
Temperature probe
2R 2 relay outputs
Transistor: transistor, <35 V AC/DC, max.100 mA, short circuit protected 2T 2 electronic outputs
Analog output: 3. Terminal strip C
Active: 0/4 ... 20 mA burden ≤500 Ω; 0/2 ... 10 V burden >500 Ω, 00 not installed
isolated, automatic burden changing (burden dependent) 2R 2 relay outputs
Passive: 4..20 mA, ext. burden = RA[Ω]≤ (supply - 5 V) ÷ 0.02 A; 2T 2 electronic outputs
supply voltage 5 ... 30 V DC AO analog output 0/4..20 mA, 0/2..10 V DC
Accuracy 0.1 %; TK 0.01 %/K 2A 2 analog outputs 4..20 mA passive
Housing: panel mounting DIN 96 x 48 mm, material PA6-GF; UL94V-0 4. Terminal strip D Supply voltage
0 230 V AC ±10 % 50-60 Hz
Dimensions: Front 96 x 48 mm, mounting depth 100 mm,
1 115 V AC ±10 % 50-60 Hz
Weight: max. 390 g
4 24 V AC ±10 % 50-60 Hz
Connection: clamp terminals, 0.08 ... 1.5 mm², AWG28 ... AWG14 5 24 V DC ±15 %
Protection class: Front IP65, terminals IP20, BGV A3 5. Options
Simulator
93
for additional accessories p.r.t. page 102 - 103
VOLTAGE CONTROLLER
Handheld instrument
HIGHLGHTS:
NEW !
Display / Controller
V 9648
Digital Voltmeter
Application: Dimensions:
The Digital Voltmeter V9648 has been designed to measure DC and AC (TRMS) voltage
Logger / EASYBus
signals. Three basic models all are selectable and makes the possibility to measure
voltages from 0 ... 30.00 mV up to 0 ... 999.9 V. Within a model the measurement range
is free programmable. Measuring of bipolar voltages is also possible with basic models
1 and 2. For example -5 ... +5 V; or -10 ... +10 V in basic model 2. Additional a free
programmable display range within ± 9999(0) digit can be assigned to a programmed
voltage measurement range.
Specifications:
Power supply
Supply voltage: 230 V AC ±10 %; 115 V AC ±10 %,
24 V AC ±10 % or 24 V DC ±15 %
Power consumption: max. 3.5 VA, with analog output 5 VA
Working temperature: -10 ... +55 °C
CE-conformity: EN 55022, EN 60555, IEC 61000-4-3/4/5/11/13
Transmitter
Input model 1: 0 ... 4000 mV DC/AC TRMS
model 2: 0 ... 250,0 V* DC/AC TRMS
model 3: 0 ... 999,9 V DC/AC TRMS
Input resistance: model 1 = 130 kΩ, model 2 = 1.3 MΩ, Ordering code:
model 3 = 2.6 MΩ
Overload: model 1 and 2 = 300 V DC/ACTRMS, V9648- 1 - 2 - 3 - 4 - 5 - 6 - 7
model 3 = 1200 V DC/ACTRMS
Accuracy: < 0.1 % ± 2 digit (DC); 0.5 % ± 2 digit (AC) Ordering code:
crest-factor < 3 → max. 2 % error, 1. Terminal strip A
crest-factor < 5 → max. 5 % error Measuring range programmable:
Temperature probe
6. Unit appears in the unit fi eld
7. Additional text above the display (3 x 90 mm H x W)
94
further information on www.greisinger.de
Display / Controller
STROM-REGLER
Handheld instrument
HIGHLGHTS:
NEW !
Display / Controller
A 9648
Digital Amperemeter
Application: Dimensions:
The Digital Amperemeter A 9648 has been designed to measure DC and AC current
Logger / EASYBus
signals. Five basic models are selectable and possible to measure currents from 0 ...
0.900 mA to 0 ... 60.0 A. The measuring range is free programmable. Measuring of bipolar
currents are possible. For example -20 ... +20 mA. Additional the free programmable
display range within ± 9999(0) digit can be assigned to a programmed current measure-
ment range.
Specifications:
Power supply
Supply voltage: 230 V AC ±10 %; 115 V AC ±10 %,
24 V AC ±10 % or 24 V DC ±15 %
Power consumption: max. 3.5 VA, with analog output 5 VA
working temperature: -10 ... +55 °C
Input model 1-4 = 0 ... 0.9 mA up to 6 A DC/ACTRMS
model 5 = 0 ... 4.5 up to 60 A ACTRMS
Transmitter
Input resistant: model 1 = 20 Ω, model 2 = 2 Ω,
model 3 = 0.2 Ω, model 4 = 0.02 Ω,
model 5 = integrated current transformer Ordering code:
Basic accuracy: < 0.1 % ± 2 Digit (DC); 0.5 % ± 2 Digit (AC)
Display: LED red, 14.2 mm A9648- 1 - 2 - 3 - 4 - 5 - 6 - 7
Indicating range: ±9999(0) Digit
Parameter display: LED 2-digit red, 7 mm Ordering code:
1. Terminal strip A
Output
1 0 ... 9.999 mA DC / ACTRMS clamp terminal
Relay: SPDT < 250 V AC < 250 VA < 2 A,
2 0 ... 99.99 mA DC / ACTRMS clamp terminal
< 300 V DC < 50 W < 2 A
Temperature probe
3 0 ... 999.9 mA DC / ACTRMS clamp terminal
Transistor: max. 35 V AC/DC max.100 mA
4 0 ... 6.000 A DC / ACTRMS clamp terminal
Analog output: 0/4 ... 20 mA, 0/2 ... 10 V, isolated 5 0 ... 60.00 A ACTRMS winding transformer
Housing: panel case DIN 96 x 48, material PA6-GF; UL94V-0 2. Terminal strip B
Dimensions: front 96 x 48 mm, mounting depth 100, 120 mm 00 not installed
(with transformer) 2R 2 relay outputs
Weight: max. 390 g 2T 2 electronic outputs
Connection: clamp terminals, 0.08 ... 1.5 mm², AWG28 ... AWG14 3. Terminal strip C
Protection class: front IP65, terminals IP20 acc. to BGV A3 00 not installed
2R 2 relay outputs
Scope of supply: Device, manual
2T 2 electronic outputs
Connection: AO analog output, 0/4 ... 20 mA, 0/2 ... 10 V
4. Terminal strip D; supply voltage
0 230 V AC ±10 % 50-60 Hz
Simulator
1 115 V AC ±10 % 50-60 Hz
4 24 V AC ±10 % 50-60 Hz
5 24 V DC ±15 %
5. Option
00 without option
01 min- and max-peak hold
07 display brightness programmable
6. Unit appears in the unit fi eld
7. Additional text above the display (3 x 90 mm H x W)
Alarm / Protection, Level
95
for additional accessories p.r.t. page 102 - 103
ALARM-DISPLAY SOLID STATE RELAYS
Handheld instrument
NEW !
FRONT
48 x 96
NEW !
Display / Controller
SD 9648 WS28D06
Alarm-Display Slimline DIN-Rail Mounted SSR
Application: WS28D12
The Alarm-Display SD 9648 will be used for indicating and evaluations of alarm signals Slimline DIN-Rail Mounted SSR
as well as analog measured values. Activation with voltage free contacts, 0/24 V signals
or 0/4 ... 20 mA for monitoring of analog measuring values. WS60D12
Specifications: Slimline DIN-Rail Mounted SSR
Logger / EASYBus
voltage drop max. 2.2 V at 20 mA
over-load limit approx. 23 mA (max. voltage 35 V). With Max. Rated Current: 6A 12 A 12 A
powerless device the inputs became a high resistance Control voltage: 4 ... 32 VDC 4 ... 32 VDC 4 ... 32 VDC
Accuracy: 0.1 %, ± 1 Digit Load voltage: 24 ... 280 VAC 24 ... 280 VAC 48 ... 600 VAC
Transmitter supply: Uo = 24 V, Ri 150 Ω, max. 50 mA Scope of supply: Device Device Device
Display: LCD-dot matrix display white / blue, character height 6.5 mm,
Display interval:
with back-lite 2 lines 16 characters each
0.5 s (refresh time)
WD28D10
DIN-Rail Mounted SSR with Integral Heatsink
Output
Relay: SPDT < 250 V AC < 250 VA < 2 A, WD60D20
Temperature probe
< 300 V DC < 50 W < 2 A DIN-Rail Mounted SSR with Integral Heatsink
Housing:
Dimensions:
panel case DIN 96 x 48, Material PA6-GF; UL94V-0
front 96 x 48 mm, mounting depth 100 mm
WD60D30
DIN-Rail Mounted SSR with Integral Heatsink
Weight: max. 390 g
Connection: clamp terminals, 0.08 ... 1.5 mm², AWG28 ... AWG14 WD60D45
Protection class: front IP65, terminals IP20 acc. to BGV A3 DIN-Rail Mounted SSR with Integral Heatsink
Scope of supply: Device, manual General:
The West family of SSRs includes WD range of DIN-rail mounted single phase devices.
The relays come in 22.5 mm and 45 mm width and range up to 45 A. The SSRs can be
Ordering code: directly mounted or DIN-rail mounted. The series also benefi t from built-in heat sink with
small panel footprint.
SD9648- 1 - 2 - 3 - 4 - 5
Application:
Simulator
• 10, 20, 30 and 45 Amps output rating
Ordering code: • 24 ... 280 V and 48 ... 600 VAC load voltage ratings
1. Inputs • 4 ... 32 VDC control voltage
1 20 digital inputs • DIN-rail or panel mounting
2 12 digital + 8 analog inputs • Epoxy-free design
2. Real time clock • IP20 touch-safe housing
0 without clock • CE and UL / cUL
• RoHS compliant
1 with clock
3. Supply voltage Specifications: WD28D10 WD60D20 WD60D30 WD60D45
0 230 V AC ±10 % 50-60 Hz
Max. Rated Current: 10 A 20 A 30 A 45 A
Alarm / Protection, Level
1 115 V AC ±10 % 50-60 Hz
Control voltage: 4 ... 32 VDC 4 ... 32 VDC 4 ... 32 VDC 4 ... 32 VDC
4 24 V AC ±10 % 50-60 Hz
5 24 V DC ±15 % Load voltage: 24 ... 280 VAC 48 ... 600 VAC 48 ... 600 VAC 48 ... 600 VAC
4. Options Scope of supply: Device Device Device Device
00 without option
5. Additional text above the display (3 x 90mm H x W)
96
further information on www.greisinger.de
Display / Controller
Handheld instrument
NEW ! HIGHLIGHTS:
Display / Controller
• Mini programmer
MAXVU 16
Logger / EASYBus
Temperature regulating device
MAXVU 8
Temperature regulating device
General: Ordering code:
The new MAXVU is a cost-effective temperature regulating device that is easy to confi -
gure, has improved display legibility and costs related to wiring and spatial requirements MAXVU 16- 1 - 2 - 3 - 4
are reduced to a minimum.
Save valuable time - confi guration in less than 60 seconds. The MAXVU was specially Ordering code:
designed for easy operability thanks to a simple confi guration and adjustment menu
1. Version
accessible via the front keypad.
• Includes 10 of the most common parameter settings 0 Standard
• Setup in less than 60 seconds for many applications 2. Supply voltage
Transmitter
• An expanded confi guration menu can be added if necessary. The easy to use MAXVU M 100 ... 240 V 50 Hz / 60 Hz AC
PC software can also be used for quick confi guration of multiple instruments. L 24 V AC / DC
3. Output configuration
Application: A A 0 logic SSR / logic SSR
MAXVU provides an affordable solution for applications with essential requirements for A R 0 logic SSR / relay
temperature regulation.
R R 0 relay / relay
• Packaging lines
• Heat treatment AA R logic SSR / logic SSR / relay
• General temperature control processes ARR logic SSR / relay / relay
• Food and beverage industry RRR relay / relay / relay
4. Option module 2
Specifications:
Temperature probe
0 without
Inputs: Thermocouple: B, C, J, K, L, N, R, S, T, C RS485 interface (ModBus RTU)
RTD: PT100 2-wire or 3-wire, linear ranges: 0/4 ... 20 mA,
0/1 ... 5 V, 0/2 ... 10 V MAXVU 8- 1 - 2 - 3 - 4
Outputs: 2 or 3 output relay or SSR
Functions: PID or On/Off regulation, direction of action adjustable to Ordering code:
‚heating exclusively‘ or ‚heating and cooling‘
1. Version
2 alarms (absolute, deviation, band, loop alarm)
Self-retaining or non-self-retaining alarm outputs 0 Standard
One or two point calibration 2. Supply voltage
Ramping and dwelling modes with variable delay time M 100 ... 240 V 50 Hz / 60 Hz AC
Reset to standard values L 24 V AC / DC
Communication: RS485 Modbus RTU 3. Output configuration
Integrated confi guration interface A A 0 logic SSR / logic SSR
Programming: Front keys or software programming A R 0 logic SSR / relay
Simulator
Accessories:
Alarm / Protection, Level
97
for additional accessories p.r.t. page 102 - 103
CAL DIGITALES THERMOSTAT DEFROSTING THERMOSTAT
Handheld instrument
FRONT FRONT
35 x 77 35 x 77
NEW !
NEW !
Display / Controller
EDT 2411
Defrosting thermostat
EDT 2412
Defrosting thermostat
for corresponding monitoring and regulation. and have a compact design that enables quick installation. The EDT defrosting models
The devices are easy to confi gure and use, are equipped with a large, easily legible are provided with a variety of functions for the optimal regulation and performance of
display and have a compact design that enables quick installation. cooling systems, including compressor protection, real-time clock and communication.
Application: Application:
Heating and cooling applications • Compressor, defrosting and fan regulation
• Thermocouple or PT100 inputs • Up to two NTC inputs for main and defrosting temperature measurement
• 2 outputs for control and for alarms • Support of manual, time-controlled and evaporator-controlled defrosting modes
• Format 35 x 77 mm (cutout 29 x 71 mm) • Format 35 x 77 mm (cutout 29 x 71 mm)
• Real-time clock (optional)
Specifications: • RS485 communication (optional)
Input: Thermocouples (J, K, T, S, R) or PT100
Specifications: EDT2411 EDT2412 EDT2423
Temperature range: PT100: -99.9 ... 300.0 °C (-99.9 ... 543.0 °F)
PT100: -200 ... 600 °C (-328 ... 1112 °F) Type and number of NTC x 1 NTC x 1 NTC x 2
Transmitter
J T/C: 0 ... 600 °C (32 ... 1112 °F) inputs:
K T/C: 0 ... 1300 °C (32 ... 2372 °F) Temperature range: -60 ... +150 °C -60 ... +150 °C -60 ... +150 °C
T T/C: 0 ... 400 °C (32 ... 752 °F) (-76 ... +302 °F) (-76 ... +302 °F) (-76 ... +302 °F)
S & R T/C: 0 ... 1700 °C (32 ... 3092 °F) Defrosting function: Manual (button or Manual (button or Manual (button or
Regulation type: On/Off, PID DI)/automatic timer DI)/automatic timer DI)/timer/ evapora-
Regulating strategy: Heating or cooling regulation tor temperature
Number of relay outputs 1 Number of relay outputs 1 2 3
(8A): (8A):
Number of SSR outputs: 1 High-current relay • •
(optional) - compressor
output (20A):
Temperature probe
TEMPERATURE CONTROLLER
Handheld instrument
HIGHLIGHTS:
FRONT • Installation depth only 63 mm
48 x 48
• Plug-in connection terminals
• Multifunction input
Display / Controller
• Presetting via configuration code
OUTPUT
KM 3 WITH ANALOG
KM
Temperature controller
General: Modell: KM - # A B C D E F G H I
Logger / EASYBus
Self-optimizing, microprocessor controlled digital controller with 2-, 3- point or PID control
mode, timer function, programmer function, 3-point step control mode with selectable set- KM ordering code:
point gradient (ramp function) # Design type
1 Controller (+ timer)
Application: 3 Controller (+ timer + programming unit)
• industrial burner • plastic injection moulding A Additional functions
• thermal power station • kitchen technology - None
• medical technology
T Timer function
Specifications: P Programmer + timer function (only KM3)
B Power supply
Inputs:
H 100 ... 240 VAC (-15 ... +10 %)
Semiconductor: PTC KTY 81-121: -50 ... +150 °C ±0.5 % of i.v.+ 1 digit
L 24 VAC (-25 ... +12 %) or 24 VDC (-15 ... +25 %)
Resistance Pt100 / 3-wire: -200 ... +850 °C ±0.5 % of i.v.+ 1 digit C Input
thermometer: Pt1000 / 2-wire: -200 ... +850 °C ±0.5 % of i.v.+ 1 digit
Transmitter
C TC, PT100, PT1000, mA, mV, V + digital input 1
Thermocouple: Type J: -50 ... +1000 °C ±0.5 % of i.v.+ 1 digit D Output OP1
Type K: -50 ... +1370 °C ±0.5 % of i.v.+ 1 digit
R Relay (1 SPST NO, 4 A/250 VAC)
Type S: -50 ... +1760 °C ±1 % of i.v.+ 1 digit
Type R: -50 ... +1760 °C ±0.5 % of i.v.+ 1 digit O VDC for SSR (12 VDC/20 mA)
Type T: -70 ... +400 °C ±0.5 % of i.v.+ 1 digit I Analog output (0/4 ... 20 mA, 0/2 ... 10 V) (only KM3)
0 ... 50 mV, 0(12) ... 60 mV: E Output OP2
-1999 ... +9999 ±0.5 % of i.v.+ 1 digit - Nonexistent
Standard signal: 0(4) ... 20 mA: -1999 ... +9999 ±0.5 % of i.v.+ 1 digit R Relay (1 SPST NO, 2 A/250 VAC)
0(1) ... 5 V, 0(2) ... 10 V: -1999 ... +9999 ±0.5 % of i.v.+ 1 digit O VDC for SSR (12 VDC/20 mA)
Outputs: M Relay (1 SPST NO, 2 A/250 VAC) (only KM3 servomotor) (note)
Output OUT1: Relay: normally-open contact, 4 A / 2 A / 240 VAC F Output OP3
Temperature probe
Semiconductor relay connection: 12 VDC, 12 mA - Nonexistent
Analog output: (0/4 ... 20 mA, 0/2 ... 10 V) (only KM3) R Relay (1 SPST NO, 2 A/250 VAC)
Output OUT2: Relay: normally-open contact, 4 A / 2 A / 240 VAC O VDC for SSR (12 VDC/20 mA)
Semiconductor relay connection: 12 VDC, 12 mA M Relay (1 SPST NO, 2 A/250 VAC) (only KM3 servomotor) (note)
Output OUT3: Relay: normally-open contact, 4 A / 2 A / 240 VAC G Output OP4
Semiconductor relay connection: 12 VDC, 12 mA D I/O digital
Output OUT4: Semiconductor relay connection: H Serial communication
12 VDC, 12 mA (programmable) - TTL
Control mode: 2-point (on / off), 3-point (neutral zone), PID, double PID S RS485 Modbus
Display: two-rowed I Terminal type
- Standard (no extensible screw terminal block)
7-segment LED: 4-digit, red / green / orange, 15.5 mm
E With extensible screw terminal block
Additional display: set value display, green, 7 mm
N With extensible terminal block (only fi xed part)
Resolution:
Simulator
KM-3 HCIR-D--
COM interface: serial RS 485 (ModBus) Art.-Nr: 605745
Housing: KM 3 with 100 ... 240 VAC (power supply), TC, Pt100, Pt1000, mA, mV, V + digital input
Protection class (Front): IP65 1 (input), analog output (0/4 ... 20 mA, 0/2 ... 10 V), relay (1 SPST NO, 2 A/250 VAC)
(outputs)
Connection: screw terminals (fi xed)
Dimensions: 48 x 48 x 63 mm (W x H x D) other design types upon request
Scope of supply: Device, manual
99
for additional accessories p.r.t. page 102 - 103
SELF-SUPPLYING PLUG-IN DISPLAY FOR MEASURING TRANSDUCER WITHOUT AUXILIARY ENERGY SOURCE
Handheld instrument
OM
DEVICE WILL TAP FR
4- 20 mA LO OP CURRENT
HIGHLIGHTS:
- S2: 2 electrically isolated open collector outputs,
connection via separate M8 jack Product-ID: 604880
Switching point, freely adjustable plug-in display with Ex-protection for all
switching hysteresis: potentially explosive atmospheres, 0-10 V
max. switching voltage: 28 V Specifications:
max. switching current: 1 A (option S1: 20 mA) as GIA ... VOT but
Reaction time: ≤ 250 ms Electric connection: Connection to any standard signal source 4-20 mA or 0-10 V
Min./Max. value memory: memorizing of max. and min. values. via 2 m connection cable.
Operation, Configuration: via 3 keys Housing: with mounting holes can be mounted to any surface.
Alarm / Protection, Level
100
further information on www.greisinger.de
Display / Controller
Handheld instrument
LED-DISPLAY
HIGHLIGHTS:
• 4 switching functions
Display / Controller
• fast controlling and supervision (reacting time <20 ms)
GRA 0420 VO
Logger / EASYBus
Product-ID: 601022
Plug on controller/display without auxiliary energy,
output 4-20 mA, 1 electrically isolated switching output.
GRA 010 VO
Product-ID: 601024
Plug on controller/display without auxiliary energy,
output 0-10 V, 1 +Ub-switching output.
Specifications: GRA 0420 ... GRA 010 ... Variants:
Input signal: 4 ... 20 mA (2-wire) 0 ... 10 Volt (3-wire) GRA 0420 VO-S2
Voltage load: < 5.5 V -- Product-ID: 605920
design type with 2 electrically isolated switching outputs. Outputs with increased switching
Input resistance: -- approx. 30 kOhm current (28 V / 1 A), connection via separate M8 jack (Delivery incl. 1 m connecting cable
Transmitter
Supply voltage: -- 12 - 28 V DC for connection of both switching outputs)
Supply current: from current loop < 10 mA GRA 0420 VO-OT
Display: approx. 7 mm high, 4 digit LED Product-ID: 605532
design type without pushbuttons in the cover (device`s adjustment is not accessible for users)
Display range: -1999 ... 9999 digit, fi rst and last value freely adjustable
GRA 010 VO-S2
Recommended range: ≤ 2000 digit Product-ID: 607650
Decimal point: any position design type with 2 electrically isolated switching outputs. Outputs with increased switching
Accuracy: ≤ 0.2 % FS ±1 digit (at nominal temperature = 25 °C) current (28 V / 1 A), connection via separate M8 jack (Delivery incl. 1 m connecting cable
for connection of both switching outputs)
Measuring rate: > 50 measurements / s
GRA 010 VO-OT
Filter: selectable in 3 stages Product-ID: 607645
Temperature probe
Limit: 3 limit functions selectable: design type without pushbuttons in the cover (device`s adjustment is not accessible for users)
LI 0: Values above/below range permissible
LI 1: Values above/below range not permissible
LI 2: When range is exceeded, the refering rail will be displayed GRA 0420 WK
Switching outputs: Product-ID: 604881
Without auxiliary energy, output 4-20 mA, 1 electrically isolated switching output.
GRA0420VO: 1 electrically isolated open collector output,
connection via cubic plug
GRA 010 WK
GRA010VO: 1 +Ub-switching open collector output, Product-ID: 604882
connection via cubic plug
Output 0-10 V, 1 electrically isolated switching output.
Option ... - S2: 2 electrically isolated open collector outputs,
connection via separate M8 jack Specifications:
Switching point, freely adjustable same as GRA ... VO, but
switching hysteresis: Electric connection: connection to any standard signal source and switching
Simulator
101
for additional accessories p.r.t. page 102 - 103
ACCESSORIES
Handheld instrument
HOUSINGS FOR SURFACE MOUNTING FOR BUILD IN OF DEVICES ALARM LIGHT WITH BUZZER
GIVES OPTICAL
AN D ACCOUSTIC ALARM
Display / Controller
Application
NEW !
ALARM 230V
Product-ID: 600913
Alarm light with buzzer
General:
Universal alarm device with fl ashlight and buzzer, which is
connected easily to relay outputs and the 230 V grid.
Specifications:
APG-4* APG-6* APG-7*
Transmitter
Color: red
Product-ID: 602827 Product-ID: 603179 Product-ID: 606825 Sound level: 92 dB
Housing for surface mounting Housing for surface mounting Housing for surface mounting Power supply: 230 V AC / 50 Hz
incl. seal GGD4896 incl. seal GGD4896 incl. seal GGD4896 Working -20 ... +50 °C
Dimensions: 75 x 125 x 126 mm (H x W x D), 175 x 125 x 126 mm (H x W x D), 72 x 122 x 126 mm (H x W x D), temperature:
without screw connections without screw connections without screw connections Protection class: IP 65
Panel cutout: for 1 display at the for 2 displays at the for 1 display at the Suitable for: e. g. GIR 2002, GIR 230, GIR 300
format 48 x 96 mm format 48 x 96 mm format 36 x 72 mm
Connection: screw connections M12 x 1.5 screw connections 2 x M12 x 1.5 screw connections M12 x 1,5
and M16 x 1.5 and 2 x M16 x 1.5
Protection class: IP65 IP65 IP65
Temperature probe
* Note: All housings without installation device and without unit sticker!
These (see page 89) have to be ordered separately!
The Installation device will be assembled for free in the housing (on common order) if desired.
Solid State Relay
Specifications:
WP66D75 Max. rated current: 10, 25, 50, 75 A
Solid State Relay Control voltage: 48 ... 660 V AC
Load voltage: 4 ... 32 V DC
Scope of supply: Device
102
further information on www.greisinger.de
Display / Controller
ACCESSORIES
Handheld instrument
POWER SUPPLY
GNG 220 / 2 GNG 12 / 300
Product-ID: 600282 Product-ID: 600274
Power supply integrated in snap-on housing for top Power supply integrated in snap-on housing
hat rail - for 2 transmitters for top hat rail
Specifications: Specifications:
Input voltage: 230 V, 50/60 Hz Input voltage: 230 V, 50/60 Hz
Output voltage: 2 x 18 V DC ±5 %, 25 mA each Output voltage: 12 V DC ±5 %, 300 mA
Dimensions: 48 x 96 x 52 mm (W x H x D) Dimensions: 70.4 x 96 x 62 mm (W x H x D)
Display / Controller
Mounting: snap-on to top hat rail Mounting: snap-on to top hat rail
Logger / EASYBus
GNG 220
Input voltage: 85 ... 264 V AC, 50 ... 60 Hz or
90 ... 375 V DC
Output voltage: 22.5 ... 28.5 V DC,
adjustable by trimmer
max. output current: 0.6 A
Dimensions: 22.8 x 75 x 102 mm (W x H x D)
DPP 15 Mounting: snap-on to top hat rail
DC/DC-CONVERTER
GNG 12 / 24 GNG 12 / 2 x 24
Transmitter
Product-ID: 600276 Product-ID: 607942
GNG 24 / 24 GNG 24 / 2 x 24
Product-ID: 600277 Product-ID: 605492
DC/DC-converter to electrically isolate 12 V DC/DC-converter
or 24 V DC-supply voltages Specifications:
Specifications: Input voltage: GNG 12 / 2 x 24: 10 - 18 V DC
Input voltage: GNG12/24: 10 - 18 V DC GNG 24 / 2 x 24: 19 - 30 V DC
GNG24/24: 19 - 30 V DC Output voltage: 2 x 24 V DC ±5 %, max. 80 mA
each, electrically isolated
Temperature probe
Output voltage: 24 V DC ±5 %, max. 80 mA,
electrically isolated
other data identical to GNG12/24 resp. GNG24/24
Insulating voltage: 500 V
Operating -20 ... +70 °C
temperature:
Mounting: snap on to top hat rail.
Dimensions: minimum space requirements due
to narrow rack housing
(module fully encapsulated).
Installation width only 22.5 mm.
GNR10 GR10
Product-ID: 603680 Product-ID: 607943
Power supply and relay module for top-hat rail, Relay module for top-hat rail for one GIA 20 EB
power supply for one GIA 20 EB and one transducer. to mounting to a top-hat rail
Specifications: Specifications:
Input voltage: 230V, 50/60 Hz Input voltage: 12 V DC
(others upon request) (others e.g. 24 VDC upon request)
Output voltage: approx. 11 V DC (unregulated) Relay outputs: 2 volt-free changeover contacts,
Alarm / Protection, Level
for the supply of a GIA20EB 18 V switching current: max. 10 A ohmic
DC ±5 % (regulated), 25 mA for load.
measuring transducer Connection: screw-type terminal
Relay outputs: 2 volt-free changeover contacts, Dimensions: 48 x 96 x 60 mm (W x H x D)
switching current: max. 10 A ohmic
load. Mounting: snap on to top hat rail
Connection: screw-type terminal
Dimensions: 48 x 96 x 60 mm (W x H x D)
Mounting: snap on to top hat rail
103
for additional accessories p.r.t. page 102 - 103
LOGGER / EASYBUS
Handheld instrument
Display / Controller
Data logger
Logger / EASYBus
EL-USB-TC-LCD
EL-USB-2-LCD
T-Logg 100 ..
T-Logg 120 ..
T-Logg 160
Application:
Standard signal ●
Temperature
Transmitter
● ● ● ●
Humidity ● ●
Device information:
EASYLog
EASYLog
EASYLog
EASYLog
EASYLog
24 RFT ..
40IMP/ ..
40NS ..
40 BIN
40 K ..
80 CL
Application:
Simulator
Standard signal ●
Temperature ● ● ●
Humidity ● ●
Pressure (abs.) ●
Alarm / Protection, Level
Pulse ●
State ●
EASYBus-load 2 2 2 2 2 2
Device information:
104
further information on www.greisinger.de
Logger / EASYBus
Handheld instrument
ISO
T-Logg
The logger series for
stand-alone applications
FUNCTIONS: T-Logg-100
Display / Controller
MIN
MAX
DIN EN 12830
EL-USB-2-LCD
Product-ID: 602982
T-Logg-100-E FREE SOFTWARE
ING-OUT
USB Data Logger for Humidity / Temperature and Dew Point FOR SETTING, READ
G
SAVING AND ANALYZIN
EL-USB-TC-LCD
Logger / EASYBus
Product-ID: 602983
USB Data Logger for external Thermocouples (J, K and T)
General: T-Logg 100
• Direct connection to USB interface
Product-ID: 600563
• 2 programmable alarm limits Temperature data logger (16.000 measurement values) for any application
• LED for indication of low battery power
• Data logger with display T-Logg 100-E
• red, green and orange LED for system status Product-ID: 600565
• Protection class IP67 Temperature data logger (16.000 measurement values) for any application
• incl. software
T-Logg 100-SET STARTER-SET
Specifications EL-USB-2-LCD: Art.-Nr. 602153
Measuring Range: Complete set: T-Logg 100 + USB 100 (incl. software)
Transmitter
Temperature: -35 ... +80 °C Specifications:
Humidity: 0 ... 100 % RH Measuring range:
Dew Point via software T-Logg 100: -30.0 ... +60.0 °C
Resolution: 0.5 °C / 0.5 % RH T-Logg 100 E: -30.0 ... +120.0 °C
Accuracy: Resolution: 0,1 °C
Temperature (typ): ± 1 °C Accuracy (at nominal temperature = 25 °C)
Humidity: ± 3,5 % RH (in the range 20 ... 80 % RH) T-Logg 100: ±0.5 °C
Dew Point: ± 2 °C (in the range 40 ... 100 % RH / 25 °C) T-Logg 100 E: ±0.2 % of measuring value ±0.5 °C
Memory: 16.382 recordings per humidity and temperature Sensor:
Temperature probe
Logging Interval: 10 s, 1 min, 5 min, 30 min, 1 h, 6 h, 12 h T-Logg 100: integrated in device
programmable via software
T-Logg 100 E: sensor tube made of stain-less steel, Ø 5 mm, approx. 50 mm
Serial Interface: USB long, approx. 1 m silicone cable. Cable with anti-buckling
Battery: 3.6 V lithium battery, size 1/2 AA, glanding to housing.
Dimensions housing: 103 x 26.4 mm (L X W), Ø 27 mm Display: LCD-display, 10 mm high
Scope of supply: 1 device incl. lithium battery 3.6 V, 1 software, 1 protection Recording interval: from 2 s ... 5 h, free programmable via software
cap, 1 operating manual (on CD-ROM), 1 clip Storage capacity: 16.000 measuring values
Specifications EL-USB-TC-LCD: Recording time: 166 days (if interval is 15 min.)
Measuring Range: Working temperature: -30 ... +60 °C
Type J: -130 ... +900 °C, Storage temperature: -40 ... +85 °C
Type K: -200 ... +1300 °C Battery: CR 2032, exchangeable
Type T: -200 ... +350 °C Battery service life: over 3 years (if recording interval is 15 min.)
Simulator
ISO ISO
T-Logg T-Logg
The logger series for The logger series for
stand-alone applications stand-alone applications
T-Logg 120-W
FREE SOFTWARE
Display / Controller
ING-OUT
FOR SETTING, READ
G
SAVING AND ANALYZIN
T-Logg 160
FREE SOFTWARE Product-ID: 600887
ING-OUT Humidity- / Temperature- Data-Logger (16.000 meas. values)
FOR SETTING, READ for any application
G
SAVING AND ANALYZIN
T-Logg 160 SET STARTER-SET
Product-ID: 602273
T-Logg 120-K Complete set with T-Logg 100 and interface converter USB 100 (incl. MINISOFT)
Logger / EASYBus
Specifications:
T-Logg 120-K-... Measuring ranges, display ranges:
Humidity: 0.0 ... 100.0 % RH
T-Logg 120-W-... Temperature: -25.0 ... +60.0 °C
Standard signal data logger (16.000 measuring values) for transducers etc.
Resolution: 0.1 °C / 0.1 % RH
Specifications: Accuracy (at nominal temperature = 25 °C):
Display range: -1999 ... 9999 digit, freely programmable
Humidity: ±3 % in range 10 - 90 %
Decimal point: any position
Temperature: ± 0.3 °C ± 0.017 * (T - 25 °C)
Input signal: only one signal!
Sensors: mounted in sensor tube
0 - 1 V, 0 - 2 V, 0 - 10 V, 0 - 20 mA or 4 - 20 mA
other input signals upon request Sensor tube: approx. Ø 15 mm made of polyamide with screw-type plastic
(input is not isolated from interface) protection cap
Transmitter
Product-ID: 602051
interface converter, for direct connection of one T-Logg to the USB-interface
Variants: of a PC.
T-Logg 120-W-E1 T-Logg 120-K-E1 GWH 40K
Product-ID: 600567 Product-ID: 600571 Product-ID: 601166
Logger with input signal 4-20 mA Logger with input signal 4-20 mA Wall suspension with lock against theft (picture: see page 112) suitable for
T-Logg 120-W-E2 T-Logg 120-K-E2 e.g. T-Logg 100, T-Logg 120 K - ... and T-Logg 160.
Product-ID: 600569 Product-ID: 600573 GWH 10
Logger with input signal 0-10 V Logger with input signal 0-10 V Product-ID: 601169
T-Logg 120-W-E3 T-Logg 120-K-E3 Simple wall suspension, made of stainless steel (picture: see page 112) Mount wall
suspension at the monitoring point, logger may now be easily put in.
Alarm / Protection, Level
Handheld instrument
AS WELL AS COOLING
ING
E.A.S.Y.Bus - Modul CHAMBERS ACCORD
OZEN FO OD 92/1/EWG
ASSIGNATION OF FR
DIN EN 12830
Display / Controller
EASYLOG-40K
EASYLOG-40KH
EASYLOG-40KH-GOF
Logger / EASYBus
Product-ID: 600542 Working temperature -30 ... +60 °C
Temperature Data Logger (48.000 meas. values) for any application, sensor tube (electronic):
are attached on the device Storage temperature: -40 ... +70 °C
Transmitter
included
EASYLOG 40KH-E600 Scope of supply: Device, manual
Product-ID: 600549
Temperature Data Logger (48.000 meas. values) for any application, tube Accessories and spare parts:
connected via cable, increased measuring range ISO-WPT3
Product-ID: 602596
EASYLOG 40KH-GOF Certifi cate of calibration -20 °C / 0 °C / +70 °C (at ...40KH)
Product-ID: 600551 ISO-WPT3L
Temperature Data Logger (48.000 meas. values) for any application, Product-ID: 603530
with surface probe for pipe mounting Certifi cate of calibration
measuring points: -20 °C / 0 °C / +60 °C (at ...40 K)
Specifications:
Temperature probe
Measuring ranges: Resolution: Accuracy (25 °C):
EASYLog 40K: -30.0 ... +60.0 °C ±0.5 °C Ordering code:
EASYLog 40KH: -50.0 ... +150.0 °C ±0.5 °C
EASYLog 40KH-E300: -50.0 ... +300.0 °C 0.1 °C ±0.5 °C ±0.2 % v. M.W. EASYLOG - 1 - 2 - 3 - 4 - 5 -GE
EASYLog 40KH-E600: 0 ... 600 °C 1 °C ±1 °C ±0.2 % v. M.W.
Greisinger
EASYLog 40KH-GOF: -50.0 ... +150.0 °C ±0.5 °C ±0.2 % v. M.W.
Sensor: Pt1000 (2-wire), ⅓ DIN, 2-wire
- Design 40K: sensor tube made of plastic, Ø 7 mm, approx. 30 mm long, 1 . Design type
(refer upper picture) attached on the device. (Note: at certifi cate: stainless steel 40K 40K
tube, Ø 5 mm, approx. 60 mm long)
40KH 40KH
- Design 40KH: sensor tube made of stainless steel, Ø 5 mm, approx. 50 mm
(refer upper picture) long, approx. 1 m silicone cable. Cable with anti-buckling 40KH-E300 40KH-E300
glanding to housing. 40KH-E600 40KH-E600
Simulator
2 m PFA-insulated cable. Cable with anti-buckling glanding
to housing. -SMB Special measuring range selectable between
Display: 10 mm high LCD-display -200 ... +600 °C
Recording interval: 2 s ... 5 h, free programmable via software GSOFT 40K Other probes see page 148-150.
Storage capacity: 48.000 measuring values
Recording time: 500 days, (if recording interval is 15 min.)
107
Software-information about logger / EASYBus p.r.t. page 75-78, asseccories see page 112
HUMIDITY-/TEMPERATURE-LOGGER
Handheld instrument
ISO
E.A.S.Y.Bus - Modul
Display / Controller
NHOUSES,
FOR MUSEUMS, GREE
EASYLOG 24-RFT GY ETC.
MEDICINE TECHNOLO EASYLOG 24-RFT-E
EASYLOG 24-RFT
Logger / EASYBus
Product-ID: 600557
Humidity-/Temperature-Data-Logger (48.000 measuring values each) for
individual use.
EASYLOG 24-RFT-E
Product-ID: 600559
Humidity-/Temperature-Data-Logger (48.000 measuring values each) for
individual use.
Specifications: Variants:
Measuring range, display ranges: EASYLOG 24RFT-ALARM
Humidity: 0.0 ... 100.0 % RH Product-ID: 602178
Humidity-/Temperature-Data-Logger with additional alarm-output, open-collector output
Temperature: -25.0 ... +60.0 °C via 4-pole miniature mounting connector (IP65) including 1 m cable. Max. switching
Transmitter
Product-ID: 602176
1 m tefl on cable
Humidity-/Temperature-Data-Logger with double battery capacity, recommended for high
Protection cap: screw-type plastic protection cap for quick responses measure-rates
Display: LCD-display, 10 mm high
Accessories and spare parts:
Recording interval: 4 s ... 5 h, free programmable via software GSOFT 40K
ISO-WPF4
Storage capacity: 48.000 measuring values each channel
Product-ID: 602543
Recording time: 500 days (if recording interval is 15 min.) Certifi cate of calibration incl. standard-measuring values (approx. 20 % / 40 % / 60 % /
Battery service life: approx. 6 years (if recording interval is 15 min.) 80 % RH increasing and decreasing; measurement point Temperature: approx. +23 °C)
Working temperature: -25 ... +60 °C EBW 3
Product-ID: 601137
Storage temperature: -30 ... +70 °C Level converter for connection of one EASYBus data logger to the USB-interface of a PC.
Interface: EASYBus-interface 3-pin mini-integral plug. (Power supply: via USB)
Needed connection-cable EBSK01 GSOFT 40K incl. EBSK 01
not included in delivery (see accessories page 112) Product-ID: 601145
Simulator
Attention: Our software GSOFT40K as well as a level converter (EBW1, EBW3 or EBW64)
are required for all EASYLOG devices for configuration and to read-out logger data. (p.r.t. page 77 and 112)
108
further information on www.greisinger.de
Logger / EASYBus
Handheld instrument
E.A.S.Y.Bus - Modul ISO
AND
FOR CONSUMPTION
ING,
FLOW RATE MEASUR E.A.S.Y.Bus - Modul
C.
PIECE COUNTING ET
EASYLOG 40NS-W
Display / Controller
NSIVE
REPLACES FOR EXPE
RECORDERS
Logger / EASYBus
Product-ID: 600555 (with PG glanding and cable)
Pulse Data Logger (48000 measuring values) for individual use Specifications:
(type TTL-signal - with PG-glanding and cable)
Display range: -1999 ... 9999 digit free programmable
Specifications: Decimal point: any position
Measuring range: 0 ... 30000 pulses/cycle
Input signals: one signal only! 0 - 2 V, 0 - 10 V, 0 - 20 mA or 4 - 20 mA, other
Resolution: 1 pulse input signals upon request (input is not isolated for EASYBus)
Cycle: 2 s ... 5 h, free programmable via software GSOFT 40K Accuracy: ±0.5 % (at nominal temperature)
Display range: -1999 ... 9999 digit free programmable Display: 10 mm high LCD-display
Decimal point: any position Recording interval: 2 s ... 5 h, free programmable via software GSOFT 40K
Input signals: Storage capacity: 48.000 measuring values
EASYLog 40IMP/S: passive volt-free switching contact Recording time: 500 days (if recording interval is 15 min.)
Transmitter
EASYLog 40IMP/T: active TTL-signal Battery service life: approx. 6 years (at 15 min)
(input is not isolated for EASYBus) Working temperature: -25 ... +60 °C
Resolution display and memory: 1 digit Storage temperature: -30 ... +70 °C
Accuracy: cycle time ±50 ms Interface: EASYBus-interface 3-pin mini-integral plug.
Display: 10 mm high LCD-display Needed connection-cable EBSK01 not included in delivery
(see accessories page 112)
Recording interval: equal to cycle
Housing: 48.5 x 48.5 x 35.5 mm (L x W x D), (with elbow-plug: 50.5 x
Storage capacity: 48.000 measuring values 90 x 39.5 mm), splash water-proof IP65
Recording time: 500 days (if recording interval is 15 min.) Electric connection: (for input signals)
Battery service life: approx. 6 years (without switching current, at 15 min) ... 40NS W: elbow-plug in accordance with
Temperature probe
Working temperature: -25 ... +60 °C EN 175301-803/A for connection to an existing transmitter.
Storage temperature: -30 ... +70 °C ... 40NS K: approx. 0.5 m connection cable
Interface: EASYBus-interface, 3-pin mini-integral plug. Noise immunity (EMC): the EASYLOG have been manufactured in accordance with
Needed connection-cable EBSK01 not included in delivery the regulations concerning EMC (2004/108/EG). The device
(see accessories page 112) meets EN 61326-1 (table 2, class B), additional error: < 0.5 %
Housing: 48.5 x 48.5 x 35.5 mm (L x W x D) Scope of supply: Device, manual
plug and cable not included, IP65
Electric connection: (for input signals) approx. 0.5 m connection cable, fl ying leads
Noise immunity (EMC): the EASYLOG have been manufactured in accordance with
Ordering code:
the regulations concerning EMC (2004/108/EG). The device
meets EN 61326-1 (table 2, class B) additional error: < 0.5 % EASYLOG40NS - 1 - 2 - 3 - 4 -GE
Scope of supply: Device, manual
Greisinger
Simulator
Ordering code:
1 . Design type
EASYLOG40IMP - 1 - 2 - 3 -GE K Cable connection
W Angle plug
Greisinger
2 . Input signal
-E1 4-20 mA
1 . Design type -E2 0-10 V
S Switching contact - with PG screw fi tting & cable -E3 0-20 mA
Alarm / Protection, Level
109
Software-information about logger / EASYBus p.r.t. page 75-78, asseccories see page 112
STATE-LOGGER HUMIDITY-/TEMPERATURE-/AIR PRESSURE LOGGER
Handheld instrument
ISO
FOR STATE
MONITORING ETC. FUNCTIONS:
MIN
MAX
MAX
ALARM
Display / Controller
E.A.S.Y.Bus - Modul
E.A.S.Y.Bus - Modul
FOR CLIMATE
MONITORING ETC.
meets EN 61326-1 (table 2, class B) additional error: in max. 64 recording sequences
< 0.5 %
Recording time: 7 years (at 15 min. interval)
Scope of supply: Device, manual
Battery service life: approx. 5 years (at 15 min)
Working temperature: -25 ... +60 °C
Ordering code Storage temperature: -30 ... +70 °C
Interface: EASYBus-interface 3-pin mini-integral plug.
EASYLOG40BIN - 1 - 2 -GE Housing: 48.5 x 48.5 x 35.5 mm (H x W x D) sensor and plug not
included. Housing made of shock resistant plastic, transparent
Greisinger front made of polycarbonate, splash water-proof:
IP 65 (excl. protection cap)
Noise immunity (EMC): the EASYLOG have been manufactured in accordance with
1 . Option the regulations concerning EMC (2004/108/EG). The device
DBK Double battery capacity meets EN 61326-1 (table 2, class B) additional error: < 0.5 %
Simulator
2 . Option
Variants:
ALARM Additional Alarm output
EASYLOG 80CL-ALARM
Product-ID: 603336
additional alarm-output, open-collector output via 4-pole miniature mounting connector
(IP65) including 1 m cable. Max. switching power: 28 V, 50 mA
Certifi cate of calibration humidity (measured points about 20 / 40 / 60 / 80% at 23 ° C)
Pressure 5 points increase, 5 points decrease over the entire measuring range
Attention: Our software GSOFT40K as well as a level converter (EBW1, EBW3 or EBW64)
are required for all EASYLOG devices for configuration and to read-out logger data. (p.r.t. p. 77 and 112)
110
further information on www.greisinger.de
Logger / EASYBus
E.A.S.Y.BUS® SYSTEM
Handheld instrument
PRINCIPLE OVERVIEW
Characteristics of the EASYBus system
• Low-cost wiring by using a twisted 2-pin connection line in either bus or Temperature monitoring
tree design (polarity-free); can be used in any combination and regulation:
Cooling chambers
• Bus line for simultaneous power supply and signal transmission Laboratory + utility rooms
Storage rooms
• Bus length up to 1000 m, extensible by using a repeater
• Fully automatic start-up installation via software
• Sensor modules can be changed, removed or added during operation Relative humidity / dew point /
Display / Controller
at any time temperature monitoring:
• Connection of up to 240 sensor modules Storage rooms, Heating systems / air
condition, Museums / exhibition rooms /
• Optimum transmission reliability by means of CRC check Libraries, Laboratories / utility rooms
• Bus system is able to process data up to 20 measuring values per second
• Response time inside the EASYBus-system approx. 1 s;
but approx. 20 ms by using a local controlling system Relative humidity / atmospheric
pressure, CO2 monitoring:
Manufacturing rooms / storage
rooms, Offi ce rooms (to condition
the air of the room), Greenhouses
Logger / EASYBus
CO monitoring:
Underground garages /
Parking garages
Motorcar garage / car repair
Measurement data
acquisition systems
Indoor go-kart tracks
for applications ranging from test
stands to climate control monitoring
Made in Germany
www.ghm-messtechnik.de
Transmitter
Company / GHM brands ,Measurement data acquisition systems`
and on www.greisinger.de.
GHM_messdatenerfassung_01_14.indd 1 19.02.2015 08:27:36
Interface converter Central data Sensor modules with measured Sensor modules without measured
acquisition value buffer (logger function) value buffer
interface converter, max. 20 channels
Interface converter
Display / regulating and monitoring
Temperature probe
EBW 1 Temperature module
for max. 14 bus loads
addressable / max. 30 bus loads
device (4 limit values), without
EB 3000
Simulator
Option
EASYBus EASYBus
EBW …
111
Software-information about logger / EASYBus p.r.t. page 75-78, asseccories see page 112
ASSESSORIES
Handheld instrument
NEW !
Display / Controller
temperature:
Humidity: 20 ... 80 % RH, 20 ... 80 % RH, 20 ... 80 % RH,
non-condensing non-condensing non-condensing
Storage temperature: -20 ... +70 °C -25 ... +70 °C -20 ...+70 °C
Dimensions: 112 x 80 x 45 mm (H x W x D) 56 x 31 x 24 mm (H x W x D) 100 x 75 x 110 mm (H x W x D)
Bit-Recovery no no yes
Scope of supply: interface converter, 9-pin Dsub interface converter interface converter, 9-pin Dsub
extension cable extension cable
Assessories:
Temperature probe
GWH 10
GWH 40K
NEW ! Product-ID: 601166
wall suspension with lock as protection against theft
suitable for all EASYLOG (except EASYLOG 40NS W),
EBN/K - ..., GIA0420WK and GRA0420WK
Simulator
112
further information on www.greisinger.de
Transmitter
TRANSMITTER
Handheld instrument
GTP-SG / GNTP-SG
GT1-CO / GT10-
S-11 .. / S-20 ..
A-10 / S-10 .. /
CVC-02 / 0201
GMUD-MP-..
TS 125 / 225
GTMU - IF ..
GRHU .. MP
GHTU .. MP
TSA PWR
MU 500 ..
T03 BU ..
Display / Controller
GITT01 ..
ST 500 ..
IR-CT 20
RT420 ..
GSMU ..
GTMU ..
WM 500
CO2-1R
GBS ..
LC...
Application:
Temperature ● ● ● ● ● ● ● ● ●
Air humidity ● ●
Flow ●
Pressure ● ●
Logger / EASYBus
Carbon monoxide / -dioxide ●
Level ● ●
Power ●
Switching contact / Namur ●
Electricity / Voltage ● ●
- Protection ● ● ● ● ●
Transmitter
Device information:
Catalogue page 115 116 117 117 118 119 120 120 121 122 123 127 124 125 137 128 126 136 141 144 144
Temperature probe
GPHU .. / GRMU ..
GEE 771C-DN...
TV 500 / ST 500
GODOX 200-...
VISION 2008 /
OXY 36 .. MP
GLMU .. MP
VTH 25 ..
CT 500 P
CVG 500
TV 125 L
CVT 500
BW 500
GS 125
CT 500
AF 500
VT 500
FT 500
EFF-...
FCM ..
pH 40
Application:
Oxygen ● ●
pH / Redox ● ●
Simulator
Conductivity ●
Rotational speed ●
Flow ● ● ● ●
Electricity ● ● ● ● ● ● ●
Alarm / Protection, Level
Voltage ● ● ● ● ● ● ●
Potentiometer ●
Frequency ● ●
Device information:
Catalogue page 129 130 132 136 135 134 131 126 130 137 138 138 142 139 139 140 140 141 143 142 143
113
further information on www.greisinger.de
FREELY SCALEABLE TEMPERATURE TRANSDUCER PT1000
Handheld instrument
ISO
HL
FL
Display / Controller
FL
GTMU-MP-AP1 GTMU-MP-AP2 GTMU-MP-AP3 GTMU-MP-AP4 GTMU-MP-SHUT
for direct screw connection for high temperatures indoor / outdoor probe duct probe with heat-
probe with threaded stem „G“ threaded stem at a distance of for direct wall mounting centrally mounted sensor tube protective shield
HL (collar tube) from housing pointing downwards (for clamping
Standard type: Standard type: ring screw connection p.r.t. p. 141)
G = ½", FL = 100 mm, D = 6 mm Standard type: FL = 50 mm, D = 3 mm
G = ½", HL = 100 mm, Standard type:
FL = 100 mm, D = 6 mm FL = 100 mm, D = 6 mm
Logger / EASYBus
please use our encapsulated or lacquered types (option).
-G5 G 3/8
Type SHUT: Heat protective shield / weather protective shield
Application: The weather protective shield is designed for -M8 M8
highly precise outdoor measurements. Strong solar radiation 6. Length of neck tube
or rain does not infl uence the measurement values. -100 100 mm
Design: Weather protective shield made of plastic, Ø 110
mm, heights approx. 140 mm. Additionally there is a wall each further 100 mm
mounting panel made of stainless steel with 3 mounting holes others on request
for screws with maximal shaft diameter 5 mm.
Largest overhang 160 mm.
114
further information on www.greisinger.de
Transmitter
Handheld instrument
ISO
Design type 1 Design type 2 Design type 3 Design type 4 Design type 5
Display / Controller
for direct screw connection for high temperatures indoor / outdoor probe duct probe for external probes
for direct wall mounting
Standard type: Standard type: Standard type: upon request
G = ½", FL = 100 mm, G = ½", HL = 50 mm, Standard type: FL = 100 mm, D = 6 mm
D = 6 mm FL = 100 mm, D = 6 mm FL = 50 mm, D = 3 mm
Logger / EASYBus
GTMU-AP4 SHUT Heat protective hat
2. Sensor element
GTMU-AP5 -P Resistance thermometer Pt100
General: -K NiCr-Ni Type K
The types 1 - 4 are supplied complete with sensor, measuring transducer etc., calibrated 3. Measuring range (MB)
and thus ready for use. Type 5 does not include sensor which is either already existing at
your works or will have to be ordered separately according to your specifi cations. -MB1 0 ... 100 °C, PT100 / Type K
-MB2 -50 ... +150 °C, Type K
Specifications: -MB3 0 ... +200 °C, PT100
Practical sensor elements: -MB4 -50 ... +50 °C, PT100
resistance thermometer: Pt100 class B, potential-free -MB5 -200 ... +300 °C, Type K
thermocouple: NiCr-Ni class 1, not potential-free -MB6 0 ... +600 °C, Type K, AP5
Transmitter
Max. measuring ranges: (not available for every design type) -MB7 0 ... +1150 °C, Type K, AP5
Pt100: -200 ... +800 °C others on request
NiCr-Ni: -200 ... +1150 °C 4. Signal output
Standard measurings ranges: -A1 4-20 mA (Standard)
Pt100: 0 ... 100 °C, 0 ... 200 °C, -50 ... +50 °C, -50 ... +150 °C -V1 0-1 V
NiCr-Ni: 0 ... 100 °C, -50 ... +150 °C, -200 ... +300 °C, 0 ... 600 °C, 0 ... 1150 °C -V3 0-2 V
Accuracy electronics: ±0.2 % FS (Pt100) or ±0.2 % ±0.5 °C (NiCr-Ni) -V4 0-5 V
Output signal: -V2 0-10 V
Standard: 4 - 20 mA (2-wire) 5. Fitting length EL
Temperature probe
Auxiliary energy:: Uv = 12 ... 30 V DC (at 0-10 V: Uv = 18 ... 30 V DC); -050 50 mm (Standard for AP3)
(for special types GTMU/GITT and GTMU/RT420: 8 ... 30 V)
-100 100 mm (Standard for AP1 / 2 / 4)
Reverse voltage 50 V permanently
protection: each further 100 mm
Allowable burden RA [Ω] ≤ (Uv [V] - 12V) / 0.02 A 6. Probe diameter D
(for 4-20 mA): (for special types GITT and RT420 refer to this pages) -3 3 mm (Standard for AP3)
Allowable load (for 0-__Volt): RL > 3000 Ω -4 4 mm
Ambient temperature 0 ... +70 °C (-40 ... +85 °C at .../RT420 and .../GITT) -5 5 mm
electronics: -6 6 mm (Standard for AP1 / 2 / 4)
Temperature coefficient: -8 8 mm
Pt100: 0.01 % / °C 7. Process connection
NiCr-Ni: 0.05 % / °C -G1 G 1/2 (Standard for AP1 / 2)
Storage temperature: -20 ... +70 °C -G2 G 1/4
Simulator
11. Option
GTMU - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 11 - 12
-GITT Electrically isolated transducer
Greisinger -RT420 Transmitter designed for outdoor phrases
12. Option
-POT Electrically isolated NiCr-Ni-probe
1. Design type
AP1 Channel /duct design with thread
115
further information on www.greisinger.de
TEMPERATURE-MEASURING TRANSMITTER TEMPERATURE-MEASURING TRANSMITTER
IN SNAP-ON HOUSING IN SNAP-ON HOUSING
Handheld instrument
ISO ISO
Display / Controller
GTP-SG GNTP-SG
Temperature-measuring transmitter in snap-on housing Temperature-measuring transmitter in snap-on housing
General: General:
Design-type: PC board completely ready for operation (sensor not included) with any mea- Design-type: PC board completely ready for operation (sensor not included) with any
suring range and any output. 3-pin connection terminal for Pt 100 in 2 or 3-wire technology. measuring range and any output. 2-pin connection terminal for NiCr-Ni-sensor or compen-
Connection terminal for output in 2-, 3-, or 4-wire technology - depending on type desired. sation line. Connection terminals for output 2- to 4-pin (depending on output in 2-, 3- or
Logger / EASYBus
4-wire technology).
Specifications:
Sensorelement: for Pt 100 resistance thermometer acc. to DIN IEC 751. Specifications:
suitable sensor can be supplied custom-designed according Sensor element: for NiCr-Ni (type K) acc. to DIN IEC 584, suitable sensor can
to your specifi cations or in standard design from stock (p.r.t. be supplied custom-designed according to your specifi cations
pages 148-151). or in standard design from stock (p.r.t. pages 20-22, 146-147)
Sensor connection: 2- or 3-wire connection. Automatic line resistance Auxiliary energy: Uv = 12 ... 30 V DC (at 0-5 V, 0-10 V: Uv = 18 ... 30 V DC)
compensation for 3-wire connection. Reverse voltage 50 V permanently
Auxiliary energy: Uv = 12 ... 30 V DC (at 0-10 V: Uv = 18 ... 30 V DC) protection:
Reverse voltage protection: 50 V permanent Permissible impedance RA [Ω] ≤ (Uv [V] - 12V) / 0.02 A
Permissible impedance RA [Ω] ≤ (Uv [V] - 12 V) / 0.02 A (at 4-20 mA):
(at 4-20 mA): Permissible load RL > 10 kΩ
Permissible load RL > 3000 Ω (at 0-__Volt):
Transmitter
GTP - 1 - 2 - 3 - 4 - 5 GNTP - 1 - 2 - 3 - 4 - 5
Greisinger Greisinger
1. Model 1. Model
Simulator
SG Temperature transmitte in snap-on housing SG Temeprature transmitte in snap-on housing
2. Sensor element 2. Sensor element
P Pt100 -K NiCr-Ni Type K
-T Pt1000 3. Measuring range
3. sensor connection -0100 0 ... 100 °C
... 2- or 3-wire -0600 0 ... +600 °C
4. Measuring range -01200 0...+1200 °C
-0100 0 ... 100 °C -5015 -50 ... +150 °C
Alarm / Protection, Level
116
further information on www.greisinger.de
Transmitter
Handheld instrument
FL
GTMU - IF1
(standard: FL = 100 mm, D = 6 mm) ISO ISO
FL
GTMU - IF2
(standard: FL = 100 mm, D = 6 mm, G1/2")
T03BU/WE
Display / Controller
*1
HL FL
Analog Pt100-transmitter (transmitter 0-10 V, set by our works)
*1
= please specify design-type desired on your order.
D
e.g. T03BU, Pt100 3-wire, 0 ... 10 V = 0 - 250 °C
GTMU - IF3 General:
(standard: HL = 100 mm, FL = 50 mm, D = 6 mm, G1/2") These transmitter are designed for industrial applications and are used to measure the
temperature through Pt100 resistance thermometers in 2-/3-wire circuits connections.
The 0 ... 10 V output signal is linear with temperature. The advantages of a continuous
analog signal path and those of digital adjustment have been combined in the realization
of this transmitter series.
GTMU-IF1 Specifications:
Product-ID: 602688
Logger / EASYBus
Measurement input: Pt100 (DIN EN60751)
Temperature transmitter Range limits: -200 ... +850 °C, with digital adjustment
GTMU-IF2 Measuring span: 40 ... 1050 K
Product-ID: 604409 Zero shift: at span < 75 K: -40, -20, 0, 20 or 40 °C
Temperature transmitter at span = 75 K: ± 50 °C
at span > 75 K: ± (span * 0.2 + 35 °C)
GTMU-IF3 Sensor connection: 2- or 3-wire connection
Product-ID: 603774 Measuring current: < 0.5 mA
Temperature transmitter Max. perm. line 11 Ohm per conductor
General: resistance (3-wire):
High precision transmitter with compact design. Sampling time: continuous because of analog signal path
Output signal: 0 … 10 Volt, 3-wire technology
Specifications:
Transmitter
Setting time on a ≤ 10 ms
Measuring range: The probe length FL has to be chosen long enough, that the temperature change:
allowable temperature range of the electronics situated in the
tube sleeve is not exceeded. Transfer characteristic: linear with temperature
Temperature probe
Electronic: ±0.2 % of measuring value ±0.2 °C
Measuring probe: standard: DIN class B Relative humidity: 0 ... 95 % RH (non condensing)
optionally higher sensor accuracy available Storage temperature: -40 … +100 °C
Output signal: 4 … 20 mA (2-wire) Electromagnetic conforming to acc. to DIN EN 61326
Auxiliary energy: Uv = 10 … 30 V DC compatibility (EMC):
other tube diameter Greisinger
G=...:
other thread
MB=...: 1. Sensor connection
other measuring ranges, set by factory P2 Pt100 (2-wire)
M12: P3 Pt100 (3-wire)
electric connection: M12 plug
2. Measuring range
... -200 ... +850 °C
MB Any measuring range desired
117
further information on www.greisinger.de
TEMPERATURE-MEASURING TRANSDUCER 4-20 MA, PT100, 2- / 3- OR 4-WIRE
Handheld instrument
ISO
CASE MOUNTING
FOR HEAD AND RAIL
HIGHLIGHTS:
RT420 with
rail adapter
Logger / EASYBus
118
further information on www.greisinger.de
Transmitter
Handheld instrument
HIGHLIGHTS:
• electrically isolated
ISO
• output linear to temperatur
• high accuracy for the entire ambient temperature range (- 40 ... 85 °C)
Display / Controller
METERS /
RESISTANCE THERMO
THERMOCOUPLES
/ VOLTAGE SENSOR
RESISTANCE SENSOR
22,5
GITT01 *1
electrically isolated, 4-20 mA universal transmitter
Logger / EASYBus
GITT01 - Ex *1
electrically isolated, 4-20 mA universal transmitter
(Ex-protection: ATEX II 1G Ex ia IIC T6/T5/T4)
Specifications: Thermocouples:
Input signal: can be universally programmed to Sensor connection: 2-wire connection
- Resistance thermometer: max. meas. range min. meas. span Sensor current: < 350 nA
Pt100 acc. to IEC 751 -200 ... +850 °C 10 K Accuracy (typ.): ±0.5 K (Type: K, J, E, L, U), ±1.0 K (Type: N, C, D),
Pt500 acc. to IEC 751 -200 ... +250 °C 10 K ±2.0 K (Type: S, B, R, MoRe5-MoRe41)
Pt1000 acc. to IEC 751 -200 ... +250 °C 10 K CJC: Pt100 internal or external (0 ... 80 °C)
Transmitter
Ni1000 acc. to DIN 43760 -60 ... +150 °C 10 K
Output signal: 4 … 20 mA or 20 ... 4 mA, 2-wire technology
- Thermocouples: max. meas. range min. meas. span
Linearisation: temperature linear, resistance linear or voltage linear
Typ B PtRh30-PtRh6 0 ... +1820 °C 500 K
Auxiliary energy: UB 8 … 30 V DC (max. ripple factor: 5 Vss for Ub>13 V)
Typ C W5Re-W26Re 0 ... +2320 °C 500 K
(ASTME 988) Electr. isolation (E/O): Ueff = 2 KV AC
Temperature probe
Typ L Fe-CuNi -200 ... + 900 °C 50 K Response time: 1 s
(acc. to DIN 43710) Output limits: 3.8 ... 20.5 mA
Typ N NiCrSi-NiSi -270 ... +1300 °C 50 K Signal in case of 3.6 mA or ≥21.0 mA, confi gurable
Typ R Pt13Rh-Pt -50 ... +1768 °C 500 K sensor damage:
Typ S Pt10Rh-Pt -50 ... +1768 °C 500 K EMC: Interference immunity and emission acc. to EN 61326-1
and NAMUR NE21
Typ T Cu-CuNi -270 ... + 400 °C 50 K
(acc. to IEC 584) Operating temperature: -40 … +85 °C
Typ U Cu-CuNi -200 ... + 600 °C 50 K Climate class: acc. to EN 60654-1, class C; condensation permissible
(acc. to DIN 43710) Vibration strength: 4 g / 2 ... 150 Hz acc. to IEC 60 068-2-6
MoRe5-MoRe41 0 ... +2000 °C 500 K Electric connection: via terminals, cross section of connection terminals
- Resistance-type max. meas. range min. meas. span max. 1.75 mm²
sensor: Housing: PC-housing, suitable for installation in connection head
acc. to DIN 43729 form B.
Simulator
119
further information on www.greisinger.de
TEMPERATURE TRANSMITTER
(ELECTRICALLY ISOLATED) ISOLATING SIGNAL CONVERTER
Handheld instrument
ISO
Display / Controller
Temperature transmitter (Pt1000)
ST500 - Ex - 10 - 0 - 00
MU500 - Ex - 51 - ... Product-ID: 603440
Product-ID: 603257 (MU500-EX-51-0-00-GN) Isolating signal converter (230 V AC)
Product-ID: 604830 (MU500-EX-51-5-00-GN)
Temperature transmitter (Pt100) ST500 - Ex - 10 - 5 - 00
Product-ID: 603627
MU500 - Ex - 53 - ... Isolating signal converter (10 ... 30 V DC/AC)
Temperature transmitter (Pt1000) General:
General: Isolating signal converter with integrated transmitter supply. It allows the direct connection of
• Electrically isolated: between input / output / supply voltage active 2-wire sensors (4 ... 20 mA) and 3-wire sensors in the Ex-area.
• 2 power-supply-designs with wide range of allowed supply voltage: • 2 power-supply-designs with wide range of allowed supply voltage:
10 ... 30 V DC / 10 ... 42 V AC or 85 ... 265 V AC / 110 ... 125 V DC 10 ... 30 V DC / AC or 85 ... 253 V AC
• Electrically isolated: between input / output / supply voltage
Transmitter
• 22.5 mm standard case for rail mounting TS35
• Several measuring ranges, selectable via rotary switch at front panel • 22.5 mm standard case for rail mounting TS35
(13 for Pt100, 16 for Pt1000) • Universal inputs/outputs for (0)4 ... 20 mA and 0(2) ... 10 V
• Offset and span adjustable For Ex-designs:
For Ex-designs: • Input intrinsically safe ATEX II (1) G [Ex ia] IIC, II (1) D [Ex iaD]
• Input intrinsically safe ATEX II (1) G [Ex ia] IIC, II (1) D [Ex iaD]
• Burden max. 1000 Ω Specifications:
Measuring ranges: selectable
Specifications:
Current input: 0 ... 20 mA or 4 ... 20 mA
Measuring ranges: selectable via rotary switch (Ri = 25 Ω, max. 100 mA overload)
Pt100: -50 ... 0, -50 ... +50, -30 ... +20, -30 ... +70, -20 ... +30, Voltage input: 0 ... 10 V or 2 ... 10 V
-20 ... +80, 0 ... 50, 0 ... 100, 0 ... 150, 0 ... 200, (Ri = ~ 40 kΩ, max. 100 V overload)
Temperature probe
0 ... 300, 0 ... 450, 0 ... 600 °C
Offset adjust: approx. ±20 %, adjustable
Pt1000: -50 ... 0, -50 ... +50, -30 ... -20, -30 ... -10, -20 ... -10,
-20 ... 0, -10 ... 0, -10 ... +10, 0 ... 10, 0 ... 20, 0 ... 30, Transmitter supply: approx. 20 V DC, Ri = approx. 300 Ω
0 ... 40, 0 ... 50, 0 ... 100, 0 ... 150, 0 ... 200 °C Output signal: 0 - 20 mA, 4 - 20 mA, 0 - 10 V or 2 - 10 V
Offset adjust: (selectable via DIP switch)
offset: approx. ±8 Ω (≙ 20 °C for Pt100, ≙ 2 °C for Pt1000)
span: approx. ±20 % max. load: burden ≤1 kΩ (at mA), load: max. 15 mA (at V)
Sensor connection: 2- or 3-wire connection Basic accuracy: ≤0.3 % of measuring range
Sensor current: approx. 1 mA (Pt100), approx. 0.25 mA (Pt1000) Temperature coefficient: ≤0.01 % / K
Output signal: 0 - 20 mA, 4 - 20 mA, 0 - 10 V or 2 - 10 V Repeat accuracy: ≤0.1 % of measuring range
(selectable via DIP switch) Rise time: T90 = < 100 ms
max. load: burden ≤1 kΩ (at mA), load: max. 15 mA (at V) Power supply: ... - 0 - 00: 85 ... 253 V AC
Basic accuracy: ≤0.2 % of measuring range ... - 5 - 00: 10 ... 30 V DC / AC
Temperature coefficient: ≤0.01 %/K Power consumption: max. 3.5 VA
Simulator
120
further information on www.greisinger.de
Transmitter
Handheld instrument
HIGHLIGHTS:
Display / Controller
• illuminated liquid crystal display
ERATURE
NON-CONTACT TEMP
... +975 °C
MEASURING FROM -50
IRCT20
Product-ID: 602832
-50 ... +975 °C, optic 22:1
Precision infrared transducer
Logger / EASYBus
Application: Accessories and spare parts:
Glass, paper, plastic industries, automotive industry, metal industry,quality assurance / MW
maintenance Product-ID: 604567
mounting bracket, fi xed
Specifications: MB
Measuring range: -50 ... +975 °C freely scaleable via programming keys Product-ID: 604568
Spectral sensitivity: 8 - 14 µm mounting bolts with M12x1 thread
Optic resolution: 22:1 (precision glass optics) MG
Product-ID: 603711
System accuracy: ± 1% or ±1 °C (higher value applicable) mounting fork, adjustable in 2 axis with M 12x1 mount
reproducibility: ±0.5 % or ±0.5 °C (higher value applicable) FVS
Nominal temperature: 23 ± 5 °C Product-ID: 603138
Temperature coefficient: 0.05 % or 0.05 °C/K (higher value applicable) standard blow clear header
FVL
Transmitter
Temperature resolution: 0.1 °C
Product-ID: 603712
Response time: 150 ms (95 %) laminar blow clear header
Emission-, transmission adjustable from 0.100 ... 1.100 ISO-WPS-IRCT
factor: Product-ID: 604967
Output signals: 0-20 mA, 4-20 mA, 0-5 V, 0-10 V, thermocouple type J or K calibration certifi cate 23 °C, 110 °C, 510 °C
Output impedance:
mA max. 500 Ohm (at 8-36 VDC)
V min. 100 kOhm load resistance
Thermo couple: 20 Ohm
Supply voltage: 8 - 36 VDC
Temperature probe
Power consumption: max. 100 mA
Cable length: 1 m (standard), 3 m, 15 m
IP rating: IP65 (NEMA-4)
Ambient temperature:
Measuring head: -20 ... +180 °C
Electronic box: 0 ... +65 °C
Further special design types (e.g. for metal processing, or with other optics) up on request
Storage temperature:
Measuring head: -40 ... +180 °C
Electronic box: -40 ... +85 °C
Relative humidity: 10 - 95 % RH, non condensing Optic resolution (standard)
Vibration (meas. head):
Simulator
Options:
CB3
3 m sensor head cable
CB15
15 m sensor head cable
CF
auxiliary lens for measuring of smallest objects
Ø meas. zone
measuring zone dia 0.6 mm @10 mm, in long distance 1.5:1 distance
121
further information on www.greisinger.de
HUMIDITY TRANSDUCER
Handheld instrument
ISO
MIN
MAX
Display / Controller
HUMIDITY
TRANSDUCER
GRHU-1R-MP
Logger / EASYBus
Housing: ABS (IP65)
Product-ID: 602938 Sensor tube: tube 14 mm Ø, with screw-type protection cap
Specifications:
GRHU - 1 - 2 - 3 - 4 - 5 -GE
Measuring ranges: Greisinger
Humidity: 0.0 ... 100.0 % RH (temperature compensated)
Temperature probe
Temperature: -40.0 ... 120.0 °C or -40,0 ... 248 °F
Recommended 20.0 ... 80.0 % RH (standard) 1. Design type
humidity range: 5.0 ... 95.0 % RH (with option high humidtiy) 1R-MP Surface design
Display options: with option UNI an alternative display unit can be shown 1K-MP Surface / duct design
instead of the humidity measuring value. The unit selection 2K-MP Duct design
will be done via keyboard.
KABEL-MP Surface design with cable and high humidity sensor
Wet bulb temperature -27.0 ... +60.0 °C
SHUT-MP Weather protective shield / heat-protective hat
Dewpoint temperature -40.0 ... +60.0 °C incl. Option LACK and HO
Enthalpy -25.0 ... +999.9 kJ/kg 2. Options Sensor
Atmospheric humidity 0.0 ... 640.0 g/kg -00 Standard sensor
Absolute humidity 0.0 ... 200.0 g/m³ -HO High humidity sensor
Accuracy: (at 25 °C and in recommended range) 3. Fitting length EL
Simulator
122
further information on www.greisinger.de
Transmitter
Handheld instrument
ISO
MIN
MAX
/-
2-CHANNEL HUMIDITY
Display / Controller
TE MP ER AT UR E
TRANSD UC ER
Logger / EASYBus
Product-ID: 602585 Sensor tube: tube 14 mm Ø, with screw-type protection cap
Transmitter
The humidity & temperature transducer offers even greater possibilities to compensate the clamps for duct mounting
special sensor characteristics due to the newest microprocessor technology. Regarding Functions: min-/max-value memory, offset and slope adjustable,
precision, temperature stability and functionality a new dimension is entered. The trans- output signal scaleable
ducer can be used for almost all applications due to the different types (e.g. wall or chan-
nel mount, with separated probe or with heat absorption hat) and the wide temperature Ordering code:
range (electronic: -25 °C ... +50 °C; sensor: -40 ... +120 °C), 2 standard signal outputs.
Temperature probe
Temperature: -40.0 ... +120.0 °C or -40,0 ... +248 °F
Recommended 20.0 ... 80.0 % RH (standard) 1. Design type
humidity range: 5.0 ... 95.0 % RH (with option high humidtiy) 1R-MP Surface design
Display options: with option UNI an alternative display unit can be shown 1K-MP Surface / duct design
instead of the humidity measuring value. The unit selection
2K-MP Duct design
will be done via keyboard.
KABEL-MP Surface design with cable and high humidity sensor
Wet bulb temperature -27.0 ... +60.0 °C
SHUT-MP Weather protective shield / heat-protective hat
Dewpoint temperature -40.0 ... +60.0 °C
incl. Option LACK and HO
Enthalpy -25.0 ... +999.9 kJ/kg
2. Fitting length EL
Atmospheric humidity 0.0 ... 640.0 g/kg
-050 50 mm (Standard for 1R)
Absolute humidity 0.0 ... 200.0 g/m³
-220 220 mm (Standard for 1K / 2K)
Accuracy: (at 25 °C and in recommended range)
-300 300 mm
Display: humidity: ±2.5 % RH
-400 400 mm
Simulator
temperature: ±0.4 % of measuring value ±0.2 °C
-500 500 mm
Output signal: humidity ±0.2 % FS, temperature ±0.2 % FS
3. Output signal
Temperature automatically
compensation: ... 4-20 mA (Standard)
Auxiliary energy: 12 ... 30 VDC or 18 ... 30 VDC (for output: 0-10 V) -AV01 0-1 V
Reverse voltage 50 V, permanently -AV01G 0-1 V (galvanically isolated)
protection: -AV10 0-10 V
Perm. impedance (at 4-20 mA): RA [Ω] ≤ (UV [V] - 12V) / 0.02 A -AV10G 0-10 V (galvanically isolated)
Permissible load (at 0-1(10)V): RL [Ω] > 3000 Ω 4. Options Sensor
Alarm / Protection, Level
123
further information on www.greisinger.de
PRESSURE MEASURING TRANSDUCER FOR ABSOLUTE PRESSURE OR
OVER/UNDER PRESSURE AND PRESSURE DIFFERENCE
Handheld instrument
HIGHLIGHTS:
• with display
• switching output
(pressure range > 25 mbar) When no pressure is applied (pressure port open), the ambient pressure is displayed.
Examples: meteorological measurements (eg 1013 hPa abs), vacuum processes
GMUD-MP - F Differential pressure is the pressure difference between 2 Press. Mostly both pressures
Pressure measuring transducer for pressure difference are connected to a respective side of the measuring membrane, the sensor must have
(fi ne pressure range ≤ 25 mbar) two pressure connections.
Examples: ventilation technology / fi lters, dynamic pressure measurements
General: The relative pressure is the pressure difference between a pressure / vacuum and the
Microprocessor controlled, digital pressure transducer with display and operation via ambient pressure. For relative pressure measurement with a differential pressure sensor
3 buttons. With freely scalable analog output that can be switched between 4-20 mA (2 pressure ports) one of the terminals is left open.
and 0-10 V. Code lock for input, after code input parameters can be changed (code Examples: pneumatic, tire pressure, hydraulic
permanently stored).
Specifications:
Application: Sensor element: piezoresistive pressure sensor with integrated temperature
Suitable for: air and non-aggressive gases Typ. accuracy: depends on type (see manual)
Area of application: ± 0.15 % (linearity)
Transmitter
MBS
GMUD MP-S-MA0: Measuring ranges: 0 … 1100 mbar abs.
option any pressure range > 25 mbar ... 5000 mbar
Product-ID: 602499 Overload: 2000 mbar, Burst pressure: 3000 mbar
please state desired measuring range
GMUD MP-S-MA1: Measuring ranges: 0 … 2000 mbar abs.
Product-ID: 602501 Overload: 4000 mbar, Burst pressure: 6000 mbar Accessories and spare parts:
Tube and accessories: see page 62 - 63.
124
further information on www.greisinger.de
Transmitter
PRESSURE MEASURING TRANSDUCER
PRESSURE TRANSMITTER FOR OVER/UNDER AND ABSOLUTE PRESSURE
Handheld instrument
ISO ISO
sealing
Display / Controller
S 10 S 11 S 20
A 10 S 10 REL
Pressure transmitter (relative pressure, zero output at atmospheric pressure) Pressure measuring transducer (Standard, zero output at ambient pressure)
Application: S 11 REL
Suitable for all applications in machine and systems engineering, automotive technology Pressure measuring transducer (Flush, zero output at ambient pressure)
as well as cooling and air conditioning technology.
Specifications:
S 20 REL
Pressure measuring transducer (Standard, zero output at ambient pressure)
Measuring range (MR), Overload limit (OL), Burst pressure (BP):
S 10 ABS
Logger / EASYBus
MR: 1, 1.6, 2.5, 4, 6, 10, 16, 25,
40, 60, 100, 160, 250, 400, 600 Pressure measuring transducer (Standard, absolute, zero output at vacuum)
OL: 2 3.2 5 8 12 20 32 50
80 120 200 320 500 800 1200 S 11 ABS
BP: 5 10 10 17 34 34 100 100 Pressure measuring transducer (Flush, absolute, zero output at vacuum)
Output signal:
400 550 800 1000 1200 1700 2400
4-20 mA, 2-wire, RA [Ω] < (Uv [V] - 8V) / 0.02 A
S 20 ABS
Pressure measuring transducer (Standard, absolute, zero output at vacuum)
0-10 V, 3-wire, RL > 10 kΩ
(other output signals upon request) General:
Auxiliary energy Uv: 8 ... 30 VDC (for output 4-20 mA) Piezoresistive pressure sensor with temperature compensation. Completely welded and
14 ... 30 VDC (for output 0-10 V) stainless steel design, fi lled food safe (up to 16 bar), thin fi lm strain (above 25 bar).
Accuracy: * ≤ 1.0 % FS (optional: ≤ 0.5 % FS), * = including non-linearity,
hysteresis, zero point and scale error. Corresponds to error of Specifications:
measurement per IEC 61298-2. Sensor adjusted in vertical
Transmitter
Measuring ranges: in bar (other values upon request)
mounting position with lower pressure connection S-10 / S-11 REL: 0.1, 0.16, 0.25,
Non-Linearity: ≤ 0.5 % FS (optional: ≤ 0.25 % FS) S-11 / S-20 REL: 0.4, 0.6, 1, 1.6, 2.5, 4, 6, 10, 16, 25, 40, 60, 100, 160, 250,
Zero Offset: ≤ 0.5 % FS (typ.), ≤ 0.8 % FS (max.), 400, 600, only S-20 REL: 1000, 1600
(Optional: ≤ 0.15 % FS (typ.), ≤ 0.4 % FS (max.)) S-10 / S-11 ABS: 0.25,
Hysteresis: ≤ 0.16 % FS S-11 / S-20 ABS: 0.4, 0.6, 1, 1.6, 2.5, 4, 6, 10, 16, only S-20 ABS: 20, 40
S-10 ABS: 0.8 ... 1.2,
Repeatability: ≤ 0.1 % FS
Available overload 3-fold at measuring range <10 bar (150 psi)
Long-term drift: ≤ 0.1 % FS (according to IEC 61298-3) pressure limits: 2-fold at measuring range ≥10 bar (150 psi)
Response time: T90 ≤ 4 ms Output signal: 4-20 mA (0-10 V - refer to options; others upon request)
Permitted temperature 0 ... +80 °C (optional: -30 ... +100 °C) Permissible impedance: RA [Ω] ≤ (Uv [V] - 10 V) / 0.02 A (for output 4-20 mA)
Temperature probe
of measurement media:
Permissible load: RL > 10 kOhm (for output 0-10 V)
Ambient temperature: 0 ... +80 °C (optional: -20 ... +100 °C)
Auxiliary energy: 10 ... 30 V DC (14 ... 30 V DC for output 0-10 V)
Storage temperature: -20 ... +80 °C
Accuracy:
Temperature 0 ... +80 °C
compensated area: deviation from ≤ 0.5 (setting of cut-off point)
parameter (% of Span): ≤ 0.25 (setting of tolerance band, BFSL)
Temperature error ≤ 1.0 % FS (typ.), ≤ 2.5 % FS (max.)
in compensated area: Repeatability (% of Span): ≤ 0.1 %
Material: Parts coming into contact with pres. media Stability/year (% of Span): ≤ 0.2 (at reference conditions)
Pressure connection: 316 L Hysteresis (% of Span): ≤ 0.1
Pressure sensor: 316 L (as of 10 bar rel. 13 - 8 PH) Permissible temperature of media: -30 ... +100 °C (refer to options)
Housing: 316 L Operating temperature ambient: -20 ... +80 °C
Pressure connection: G ¼ A, DIN 3852-E with NBR sealing Compensated temperature range: 0 ... +80 °C
Protection rating: IP65 or IP67 with cable Temperature coefficient: ≤ 0.02 % FS / K (or ≤ 0.04 % FS for MB ≤ 0.25 bar)
Simulator
(-1.0 ... +1.5 bar, -1.0 ... +3.0 bar, -1.0 ... +9.0 bar) Options:
G2 Special measuring range
Higher sensor accuracy (class 0.5)
Media temperature: -40 ... +125 °C (S-10/-20 only)
T2
Extended temperature range: -30 ... +100 °C Media temperature: -30 ... +125 °C (S-11 only)
V2 Media temperature: -20 ... +150°C
Output signal 0-10 V (S-11 only with cooling section)
Fixed connecting cable Output signal 0-10 V (other upon request)
2 m with bend protection (instead of elbow-type plug, IP67) Ex-protection
125
further information on www.greisinger.de
WATER LEVEL / WELL PROBE INLINE COMPRESSED AIR FLOWMETER FOR
TANK CONTENTS MEASURING PROBE COMPRESSED AIR CONSUMPTION MEASUREMENTS
Handheld instrument
XPENSIVE
FOR SIMPLE AND INE
APPLICATIONS
Display / Controller
Product-ID: 603146
Tank contents measuring probe for diffi cult measuring conditions Flowmeter with DN25 sensor and assembly ball valve DN25
General: Application:
Leakage detection: Consumption of compressed air despite of shut-down installations
For measuring the level of fuel and other aggressive media. The sensor is highly precise,
is a serious hint for a leak in one of the pipes (even a 1.5 mm sized hole can already yet
insensitive to lateral fl ow and offers optionally lightning protection and other output signals
energy costs of € 1.500!)
(e.g. 0-10 V). For measuring of gasoline please order ex-design.
Improvement in efficiency: Compressed air is one of the most expensive form of energy
in many plants! Therefore the knowledge about the consumption is essential for the appli-
Beschreibung:
cation of an energy management system (e.g. acc. to DIN50001)
Piezoresistive pressure sensor with temperature compensation. Welded, non-corrosive
design with integral and additionally sealed water-proof connecting cable. The pressure General:
compensation is done via a cable-integrated air path to the atmosphere. A special feature
The inline fl owmeter is based on the thermal mass fl ow measuring principle and is well
is the lateral fl ow resistance, which prevents media ingress.
suited for fl ow measurements in pipes DN15 till DN25. It allows measuring the consumption
of compressed air (optionally also nitrogen, CO2, oxygen, helium or other non-
Specifications:
Transmitter
corrosive, incombustible gases).
Measuring ranges: 0.1 bar (100 mbar) ... 10 bar = 1 ... 100 m water column The device sets standards in terms of accuracy and repeatability, its unique mounting
Available ranges: 0.1, 0.25, 0.4, 0.6, 1, 1.6, 2.5, 4, 6, 10 concept as well as its close-to-application adjustment at a pressure of 7 bar.
The mounting in a measurement assembly ensures easy installation and removal of the
Overload (bar): 1 2 2 3 5 8 8 10 10 10
sensor for regular calibration and assures at the same time an exact and reproducible
Output signal: 4-20 mA (option: 0-10 V only for GBS02) positioning of the fl ow sensor in the pipe. There are two signal outputs to read-out the
Permissible impedance: 4-20 mA: RA [Ω] < (Uv [V] - 10 V) / 0.02 A measured values. Depending on the application the outputs can be confi gured as analog
output (current or voltage), switching output or pulse output for consumption measure-
Permissible load: 0-10 V: RL [Ω] > 100 kOhm
ment.
Auxiliary energy: 10 ... 30 V DC (14 ... 30 V DC at 0-10 V) Configuration software
Accuracy: accuracy (% of span): The fl ow meter can be confi gured to its desired use by means of its integrated USB inter-
GBS01: ≤ 0.5 setting of cut-off point) resp. ≤ 0.25 (BFSL) face and a software included in shipping.
Functions of the software:
Temperature probe
GEE-KH-DN20
Options GBS02: Product-ID: 604560
Assembly ball valve DN20
extra long connection cable (FEP, teflon)
till max. 100 m GEE-KH-DN25
Product-ID: 607966
output signal 0-10 V Assembly ball valve DN25
126
further information on www.greisinger.de
Transmitter
Handheld instrument
GSMU 1020 C5:
sensor tube connected
via cable
Display / Controller
GSMU 1020 B5:
sensor tube permanently connected
Logger / EASYBus
• selection between 2 different response times
• high accuracy Application:
• almost independent of fl ow direction • heating, ventilating
• shock resistant • air conditioning technology
• resistant to pollution • supply air control of ovens
Application: Specifications:
Air conditioning and ventilation technology, process and environmental technology Working range: 0 ... 20 m/s
Measuring principle: other upon request
no moving parts. Hot-fi lm anemometer principle. Output signal: 0 ... 10 V (max. 1 mA)
Specifications: Accuracy: at 20 °C / 45 % RH, 1013 hPa, at 1 ... 20 m/s
±(0.4 m/s + 6 % of measured value)
Measuring range flow:
Response time: typ. 4 s
GSMU 1020..: 0 ... 10 m/s, 0 ... 15 m/s and 0 ... 20 m/s (at 10 m/s T90)
Transmitter
Measuring range can be set by means of jumper.
Power supply: 19 ... 29 V DC
Output signal: 0 - 10 Volt (Iout < 1.0 mA) or
4 - 20 mA (Ri < 450 Ohm) Power consumption: max. 70 mA
Output signal can be set by means of jumper. Temperature range: working temperature: -20 … +60 °C
Measuring accuracy: (at 20 °C, 45 % RH, 1013 hPa) storage temperature: -30 … +60 °C
0 ... 10 m/s: ± 0.2 m/s ± 3 % of measured value Connection: 0.5 m cabel, PVC 3 x 0.25 mm², wire end ferrule
0 ... 15 m/s: ± 0.2 m/s ± 3 % of measured value Electromagnetic EN61326-1
0 ... 20 m/s: ± 0.2 m/s ± 4 % of measured value Compatibility (EMC): EN61326-2-3
Response time: T90 typ. 4 s or 0.2 s Housing: Polycarbonate, length: 120 mm, Ø 12 mm
(at 10 m/s) Response time can be set by means of jumper. Protection class: IP20 (measuring head), IP40 (housing)
Dependency on flow
Temperature probe
< 3 % of measured value at < 10°
direction: Accessories and spare parts:
Voltage supply: 24 V AC / DC ±20 %, max. 150 mA GNG 24/150
max. load: 500 Ohm Product-ID: 600275
power supply: 24 VDC, 150 mA
Connection: screw-type terminals up to 1.5 mm²
Operating temperature: -10 ... +50 °C
Storage temperature: -20 ... +60 °C
Housing: 80 x 80 x 35 mm (H x W x D)
Material: ABS
Protection rating: IP65 (electronic box)
Sensor tube: length = 200 mm (+18 mm for sensor head), Ø 12 mm
GSMU...B5: sensor tube permanently connected to housing
GSMU...C5: sensor tube connected to housing via cable (approx. 1 m
Simulator
long); Other tube or cable lengths upon request.
Electromagnetic Conforming to acc. to DIN EN 50081-1 and DIN EN
Compatibility (EMC): 50082-2
Product-ID: 603810
mains transformer: 230 V~ to 24 V~, with mounting clamp and screw-type terminals.
Dimensions approx. 62 x 56 x 32.5 mm
127
further information on www.greisinger.de
CO-TRANSDUCER CO2-TRANSDUCER
Handheld instrument
E ACC.
WITH TÜV CERTIFICAT
TO VDI 2053 FOR
STEMS
CO SURVEILLANCE SY
MAX
ALARM
IN UNDERGROUND
GARAGES ETC. MIN
MAX
Display / Controller
GT1-CO
Product-ID: 602858
CO-Transducer
General: GT10-CO2-1R
High quality, TÜV certifi ed CO transmitter for detection of carbon monoxide in under- Product-ID: 602599
ground garages, parking garages, boiler plants, heating systems, garages as well as in the CO2-Transducer
ambient air. The CO transducer has a very long-lasting electrochemical measuring cell
and could be easily integrated in existing CO surveillance systems (without loss of validity
General:
of existing TÜV certifi cates). Via two-wire system, displays, controller and alarm devices Due to the fact, that CO2 is an important indicator for the quality of air in rooms, it‘s super
with 4-20 mA input could be connected without any problem. important to measure the CO2 content. The recommended CO2 limit value for ambient air
Logger / EASYBus
Highlights: is 1000 ppm. An exceeding of this limit causes tiredness and a loss of concentration.
• TÜV certifi cation according to VDI 2053 The high quality and precise CO2-transducer works according to the infrared principle
• also suitable as replacement sensor for existing CO surveillance systems (NDIR). An auto-calibration procedure compensates aging effects and is responsible for
• long-lasting electrochemical measuring cell an excellent long term stability of this CO2 transducer.
• automatic zero calibration Due to the freely adjustable output signal the transmitter could be used for nearly each
• 3 years warranty for the co sensor element existing controller input etc. Additionally, there is a local display which shows beside the
actual CO2 concentration, the minimum and maximum values as well as an optical alarm.
Application: Highlights:
• excellent long term stability
• underground garages, parking garages
• auto-calibration procedure
• boiler plant and heating systems
• for surveillance of the recommended CO2 concentration in ambient air
• motorcar garage
• output signal free scaleable
Specifications:
Specifications:
Measuring range: 0 ... 300 ppm CO (carbon monoxide)
Measuring range: standard: 0 ... 2000 ppm CO2 (carbon dioxide)
Transmitter
gas bottle with 12l test gas: 30 ppm CO output signal 0 - 10 V
GZ-03
Product-ID: 603123 Accessories and spare parts:
gas bottle with 12l test gas: 300 ppm CO GSN 24-750
GZ-04 Product-ID: 604387
Product-ID: 603570 plug-in power supply (230 VAC => 24 VDC/750 mA)
gas valve unit MiniFlo for gas bottles with 12l
GSN-24
Product-ID: 604386
plug-in power supply (230 VAC => 24 VDC/300 mA)
128
further information on www.greisinger.de
Transmitter
OXYGEN MEASURING TRANSDUCER
AIR OXYGEN MEASURING TRANSDUCER FOR DISSOLVED OXYGEN IN LIQUIDS
Handheld instrument
ISO
OXY 3610 MP
Product-ID: 602029
oxygen measuring transducer incl. sensor
Display / Controller
Specifications:
OXY 3690 MP Messbereiche:
Product-ID: 602027 oxygen concentration: 0.00 ... 25.00 mg/l (dissolved)
Air oxygen measuring transducer incl. sensor temperature: 0.0 ... 50.0 °C
Specifications: Accuracy device (at nominal temperature 25 °C):
Measuring ranges: oxygen: ±1.5 % of m.v ± 0.2 mg/l
oxygen concentration: 0.0 ... 100.0 % O2 (gaseous) temperature: ±0.1 °C ± 1 digit
temperature: -20.0 ... +50.0 °C Output signal (only O2): 4 - 20 mA (2-wire - standard), 0 - 10 V (3-wire - option)
Accuracy device (at nominal temperature 25 °C): Electric isolation: input electrically isolated
oxygen: ±0.1 % ± 1 digit Auxiliary energy: 12 ... 30 V DC (at output 4-20 mA)
temperature: ±0.1 °C ± 1 digit 18 ... 30 V DC (at output 0-10 V - Option)
Logger / EASYBus
Output signal (only O2): 4 - 20 mA (2-wire - standard), 0 - 10 V (3-wire - option) Perm. impedance (at 4-20 mA): RA [Ω] ≤ (Uv [V] - 12 V) / 0.02 A
Electric isolation: input electrically isolated Permissible load (at 0-10 Volt): RL > 3000 Ω
Auxiliary energy: 12 ... 30 V DC (at output 4-20 mA) Working condition: 0 ... +50 °C, 0 ... +95 % RH (non-condensing)
18 ... 30 V DC (at output 0-10 V - option) Storage temperature: -20 ... +70 °C
Perm. impedance (at 4-20 mA): RA [Ω] ≤ (Uv [V] - 12 V) / 0.02 A Reverse voltage protection: 50 V permanently
Permissible load (at 0-10 Volt): RL > 3000 Ω Display: approx. 10 mm high, 4-digit LCD-display
Working condition: 0 ... +50 °C, 0 ... +95 % RH (non-condensing) Housing: ABS (IP65 - with the exception of sensor plug)
Storage temperature: -20 ... +70 °C Dimensions: 82 x 80 x 55 mm (without elbow-type plug and sensor plug)
Reverse voltage protection: 50 V permanently Electric connection: elbow-type plug acc. to EN 175301-803/A (IP65), max. wire
Display: approx. 10 mm high, 4-digit LCD-display cross section: 1.5 mm², wire diameter from 4.5 ... 7 mm
Housing: ABS (IP65 - with the exception of sensor plug) Sensor connection: 5-pin jack connector, screwable
Transmitter
Dimensions: 82 x 80 x 55 mm (without elbow-type plug and sensor plug) Calibration: 1-point calibration: simple quick calibration in atmospheric air.
Electric connection: elbow-type plug acc. to EN 175301-803/A (IP65), max. wire Oxygen sensor (GWO3600MU):
cross section: 1.5 mm², wire diameter from 4.5 ... 7 mm
Type: active membrane type, with integrated NTC-resistor
Sensor connection: 5-pin jack connector, screwable
Response time: 95 % in 10 s, depending on temperature
Calibration: 1-point calibration in atmospheric air.
Operation life: 3 years or more, depending on maintenance
Air pressure compensation: 500 ... 2000 hPa abs., manually input
Operating pressure: max. 3 bar.
Oxygen sensor: Flow rate: min. 30 cm/s
Sensor type: GGO 370 / MU Build in diameter: Ø 12.0 ±0.2 mm (suitable for ½“ screw connection)
Measuring range: 0.0 ... 100.0 % O2 Overall length: approx. 220 mm (with anti-buckling glanding)
Temperature probe
Response time T90: <10 s, depending on temperature Build in length: approx. 110 mm
Warranty: 12 months Connection cable: approx. 4 m, with 5-pin plug, screwable
(assuming appropriate usage according to the manual) Warranty: 12 months
Application area: suitable for air and pure oxygen, Working temperature: 0 ... +40 °C
suitable for high CO2-concentrations
Scope of supply: device incl. electrode, GWOK01 and KOH100
Temperature compensation: integrated in sensor housing
Connection cable: approx. 1.3 m, with 5-pin plug, screwable Variant:
Operating pressure: 500 ... 2000 hPa (static). OXY3610MP-V2
For air and gas-stream use the option GOO.../MU. Product-ID: 602720
output signal 0-10 V
Working condition: 0 ... +45 °C, 0 ... +95 % RH (non-condensing)
Storage temperature: -15 ... +60 °C Accessories and spare parts:
Dimensions of housing: approx. Ø 40 x 103 mm (153 mm incl. anti-buckling glanding), GWO 3600-L04-MU
Simulator
129
further information on www.greisinger.de
OPTICAL OXYGEN CONVERTER PH-MEASURING TRANSDUCER WITH ON SITE DISPLAY
Handheld instrument
HIGHLIGHTS:
• automatically and
LOW MAINTENANCE manually temperatur
IS
ISO
& ROBUST compensation
• external Pt1000-
temperature probe
NEW ! connectable
ISOLATION
• Two 4-20 mA (or 0-5 V) outputs: concentration and saturation
Product-ID: 600704
Scope of supply: Transmitter (consisting of sensor body and evaluation, standard electrode, BNC-plug (thread adapter PG 13,5 optional available)
connected via cable), storage cap GE 100-Cinch
Product-ID: 600702
Option: standard electrode, Cinch-plug (thread adapter PG 13,5 optional available)
Cable length 10 m GE 117-BNC
Cable length 15 m Product-ID: 600730
Cable length 30 m pH electrode with integrated Pt1000-sensor, 1 x BNC-plug and 1 x banana plug Ø 4 mm,
thread PG13.5, pressure resistant up to 6 bar
Accessories and spare parts: GE 173-BNC
Alarm / Protection, Level
130
further information on www.greisinger.de
Transmitter
FLOW MEASURING TRANSDUCER
REDOX-MEASURING TRANSDUCER WITH HALL-EFFECT SENSOR
Handheld instrument
Display / Controller
WITH ELECTRICALLY
FOR LOW VISCOSE,
ISOLATION UIDS
NON AGGRESSIVE LIQ
Dimensioned sketch
GPHU / GRMU:
Logger / EASYBus
Product-ID: 602021 • minimum size, maximum accuracy
Redox-measuring transducer without electrode, Cinch-connection • easy installation
• installation in any position possible
Specifications: • optimum-quality due to high-quality materials used
Measuring range: ±2000 mV or special limited measuring ranges acc. to • no maintenance
customer specifi cation!
Accuracy: 0.2 % FS (at nominal temperature = 25 °C)
Application:
• manufacturing of oil and gas burners, fl ow heaters or cooling systems
Output signal: 4 - 20 mA (2-wire), standard
• for dish washers and washing machines
0 - 10 V (3-wire), upon upcharge
• automotive technology (measuring of petro consumption, etc.)
Electric isolation: input electrically isolated • laboratories, chemical works, pharmaceutical industry
Auxiliary energy: 12 ... 30 V DC (for option 0-10 V: 18 ... 30 V DC) • agriculture and horticulture
Perm. impedance (at 4-20 mA): RA [Ω] ≤ (Uv [V] - 12 V) / 0.02 A
Specifications:
Permissible load (at 0-10 Volt): RL > 3000 Ω
Transmitter
Rotor-position scanning: hall sensor
Input resistance: 1012 Ohm
Measuring range: 1.5 ... 25 l/min
Electrode socket: BNC-socket or Cinch-socket
Resolution: approx. 1000 pulses/l
Option: on site display approx. 10 mm high, 4-digit LCD-display
Measuring agent: clean liquids, we recommend fi ltering with approx. 20 ... 40
Working temperature: 0 ... +50 °C (electronic) micron
Storage temperature: -20 ... +70 °C Viscosity: up to approx. 15 cSt.
Electric connection: elbow-type plug acc. to EN 175301-803/A (IP65) Accuracy: ±3 % ranging from 10 - 10 %
Housing: ABS (IP65) with the exception of electrode connection Repeatability: < 0.5 %
sockets. (cpl. IP65 upon request)
Working temperature: -20 ... +100 °C
Dimensions: 82 x 80 x 55 mm (H x W x D)
Operating pressure: 25 bar
Temperature probe
Mounting: with fi xing holes for wall mounting (accessible after removal of
Electric connection: elbow-type plug acc. to EN 175301-803/A, type C industrial
cover), Mounting distance: 70 x 50 mm (W x H)
Fixing screws: max. shaft-Ø 4 mm Auxiliary energy: 5 - 24 V DC, approx. 8 mA
Multiplier (R): 1 - 2.2 kOhm
Option:
Output signal: frequency 5 - 416 Hz, open collector NPN
VO:
Output current: max. 20 mA
on site display
Material:
V2:
output signal 0-10 V Housing: Grilamid TR55 (PA12)
MB...: Rotor: Grilamid (PA12 Ferrit)
limited measuring range (please state the desired range) Bearings: PTFE 15 % graphite
Ordering example: Delivery connection: G 3/8“ thread
GRMU 2000 MP-BNC-VO: DN: 8 mm
Simulator
Product-ID: 607802
Redox electrode with S7-plug
GR 175-BNC
Product-ID: 607801
Redox electrode with BNC-plug
PG 13,5
Product-ID: 603205
plug on thread adapter for pressureless use, with external thread PG 13.5
(suitable for any electrode with shank diameter 12 mm)
For additional electrodes and accessories p.r.t. page 48/49
131
further information on www.greisinger.de
CONDUCTIVITY MEASURING TRANSDUCER
Handheld instrument
HIGHLIGHTS:
ISO • Compact measuring cells
• Freely scalable
• Local display
Laboratory measuring cells Optional PG (with PG 13.5 thread) Professional, field installation M12,
best value up to 6 bar (@ 22 °C) G 1/2 A fitting, max. 16 bar (@ 22 °C)
Standard cable length: 1 m Standard cable length: 1 m Standard cable length: 5 m
Logger / EASYBus
PG 13,5 THREAD
GLMU 200 MP-TR
Conductivity measuring transducer, PROFESSIONAL
incl. 2-pole measuring cell
General: GLMU 200 MP-TR GLMU 200 MP-TR-PG GLMU 200 MP-TRP*)
Product-ID: 607814 Product-ID: 607815 Product-ID: 607816
2-pole measuring cells,
suitable for use in clean / potable / fresh Ø 12 mm 2-pole measuring cell LFE 202 Ø 12 mm 2-pole measuring cell LFE 202-PG Ø 16 mm 2-pole measuring cell LFE 230
water Graphite, C=1.0; -5 ... +80 °C Graphite, C=1.0; -5 ... +80 °C Graphite, C=0.9; 0 ... +60 °C (higher
Recommended usage range: available on request)
up to 2000 μS/cm
4 Measuring ranges:
0.1 µS/cm ... 200.0 mS/cm
Transmitter
PG 13,5 THREAD
GLMU 400 MP-SW
Conductivity measuring transducer,
PROFESSIONAL
incl. 4-pole measuring cell
General: GLMU 400 MP-SW GLMU 400 MP-SW-PG GLMU 400 MP-SWP*)
Product-ID: 607819 Product-ID: 607820 Product-ID: 607821
4-pole measuring cells,
especially well-suited for use above Ø 12 mm 4-pole measuring cell LFE 400 Ø 12 mm 4-pole measuring cell LFE 400-RW Ø 16 mm 4-pole measuring cell LFE 430
2000 μS/cm, applications susceptible to Graphite, C=0.55; -5 ... +80 °C Graphite, C=0.55; -5 ... +80 °C Graphite, C=0.4; 0 ... +60 °C (higher
contamination, sea water, etc. available on request)
5 Measuring ranges:
Temperature probe
0.1 µS/cm ... 500 mS/cm
2-pole measuring cells, Ø 12 mm 2-pole measuring cell LFE 210
suitable for use in organic substances Platinum glass; C=1.0
(alcohol, benzine, diesel)
Usage range up to 1000 μS/cm
2 Measuring ranges:
0.1 µS/cm ... 2000 μS/cm
*) Attention:
A special cable is supplied with the professional version.
The measuring cell can be unscrewed locally without having to change the
wiring!
132
further information on www.greisinger.de
Transmitter
Handheld instrument
General: Accessories and spare parts:
Cheap conductivity measurement in drinking water, sea water, process water and waste- GLMU 400 MP-UNI-AV010
water, operational. Product-ID: 608006
GLMU 400 MP-UNI-AV01
Specifications: GLMU 400 MP GLMU 200 MP GLMU 200 MP-RW Product-ID: 608053
Measuring ranges: (customer-selectable) GLMU 400 MP-UNI-AV420
Product-ID: 608052
Conductivity: 0.0 ... 200.0 µS/cm 0.0 ... 200.0 µS/cm 0.0 ... 200.0 µS/cm Transmitter without measuring cell, suitable for
0 ... 2000 µS/cm 0 ... 2000 µS/cm 0.00 ...20.00 µS/cm 2- and 4-pol. measuring cells to create your own
0.00 ... 20.00 mS/cm 0.00 ... 20.00 mS/cm conductivity measuring system with special
0.0 ... 200.0 mS/cm 0.0 ... 200.0 mS/cm measuring cells. Different standard systems:
0 ... 500 mS/cm • Area selection of cell constant 0.01; 0.1; 1.0; 10,
specific Resistance: 0.0 ... 200.0 5.0 ... 100.0 0 ... 200 kOhm*cm for example, 1.0 corresponds to 0.300 ... 1.200,
Display / Controller
kOhm*cm kOhm*cm 0 ... 2000 kOhm*cm 0.1 corresponds to 0.0300 ... 0.1200
0.00 ... 20.00 0.50 ... 10.00 • Depending on this measuring range selection
kOhm*cm kOhm*cm without limitations (5 regions)
1 ... 5000 Ohm*cm 50 ... 1000 Ohm*cm • selection of temperature input Pt1000 or NTC10 k
1.0 ... 500.0 5.0 ... 100.0
Ohm*cm Ohm*cm Note: The measuring accuracy of the overall
1.00 ... 50.00 system strongly from the measuring cell used and
Ohm*cm the dependent on the area of application
TDS: 0.0 ... 200.0 mg/l 0.0 ... 200.0 mg/l 0.0 ... 200.0 mg/l LFE-202
0 ... 500.0 mg/l 0 ... 2000 mg/l 0.00 ... 20.00 mg/l Product-ID: 604344
0 ... 2000 mg/l 2-pole spare measuring cell (for GLMU 200 MP-TR)
0.0 ... 20.0 g/l LFE-202-PG
0 ... 200 g/l Product-ID: 603594
Logger / EASYBus
Salinity: 0.0 ... 70.0 (PSU) 0.0 ... 70.0 (PSU) 2-pole spare measuring cell (for GLMU 200 MP-TR-PG)
Temperature 5.0 ... +140.0 ° C (device) LFE-230
measurement: permissible temperature of the measuring cell note! Product-ID: 607825
Measuring cell: 4-pole. measuring cell 2-pole. measuring cell 2-pole.measuring cell 2-pole spare measuring cell (for GLMU 200 MP-RWP)
Standard conductivity measuring cell with integrated temperature sen- LFE-400
measuring cell: sor. Cell constant determined from the factory and preset. Product-ID: 604635
4-pole spare measuring cell (for GLMU 400 MP)
Accuracy: (at nominal temperature = 25 °C)
LFE-400-PG
Conductivity: 0.5% of reading ± 0.3% FS (-RW: ±1 % v. MW ±0.3 % FS) Product-ID: 603565
Temperature ±0.2 °C ±1 Digit 4-pole spare measuring cell (for GLMU 400 MP-PG)
measurement: LFE-430
Cells Connection: 7-pin DIN socket Product-ID: 607827
Cell constant: K = 0.30 ... 1.20, adjustable (-RW: 0.03 ... 0.12) 4-pole spare measuring cell (for GLMU 400 MP-Pro)
LFE-240
Transmitter
Temperature off: no compensation
compensation: Lin: linear compensation (of 0.3 ... 3.0 % / K) Product-ID: 607828
(customer-selectable) nLF: non-linear function of natural water according 2-pol. Replacement measuring cell (for GLMU 200 MP-RW)
toEN27888 (ISO 7888) LFE-220
in salinity: automatically after IOT Product-ID: 607829
Display: approx. 10 mm high, 4-digit LCD display 2-pol. Replacement measuring cell (for GLMU 200 MP-RW-Pro)
Output signal: 4 - 20 mA (2-wire), standard LFE-210
0 - 1 V or 0 - 10 V (3-wire), surcharge Product-ID: 606991
2-pol. Replacement measuring cell (for GLMU 200 MP-LTG)
Galvanic isolation: input electrically isolated
PG 13.5
Power supply: 12 ... 30 V DC (for option 0-10 Volt: 18 ... 30 V DC) Product-ID: 603205
Reverse polarity: 50 V continuous Plug on thread adapter for pressureless use, for electrodes
Temperature probe
perm. burden (4-20 mA): RA [Ω] ≤ (Uv [V] - 12 V) / 0.02 A with 12 mm shank diameter
Options:
AV010:
Output signal 0-10 V
AV01:
Output signal 0-1 V
KL=..:
longer measuring cell cable (recommended max. 5 m)
Alarm / Protection, Level
133
further information on www.greisinger.de
AXIAL TURBINE FLOW SENSOR
FLOW SENSORS FLOW SENSORS FOR LIQUIDS
Handheld instrument
Display / Controller
range: continuous operation (signal emission
Flow connections: 2 x G1/4“ IG parallel Flow connections: 2 x G¼“ IG parallel as of 1 l / min)
Working temperature: -10 ... +100 °C Working temperature: -10 ... +65 °C Resolution: approx. 65 pulses / litre
Material housing: brass (lead-free) Material housing: PEEK, sealing: Viton Measuring agent: liquids
Nuzzle: Inox 1.4305 Magnets: neodymium (not in contact with medium) Max. particle size: 0.5 mm
Magnets: ceramic SrFeO Dimensions: approx. 88 x 68 x 57 incl. plug Measuring ±3 % of measured value
(in contact with medium) accuracy:
Sealing: silicone Repeatability ±0.5 %
Dimensions: approx. 50 x 40 x 39 mm Working Tmax = 85 °C
(w/o plug) M12 - CONNECTION CABLE temperature:
Temperature probe
KM4P-G10 connection:
Product-ID: 604518 Nominal width: DN 25
straight connector, 4-pole, 10 m cable
KM4P-W02
Product-ID: 604104
90° connector, 4-pole, 2 m cable
KM4P-W10
Product-ID: 607963
Alarm / Protection, Level
90° connector, 4-pole, 10 m cable
KM4P-GL
Product-ID: 607964
connector for self-tailoring, 4-pole
General:
Screened PUR-connection cable with moulded
M12x1-connector (and loose ends). Available in straight
and angular design.
134
further information on www.greisinger.de
Transmitter
FLOW SENSORS FOR VARIOUS APPLICATIONS
(SUITABLE EVALUATION DEVICES: GIA20EB, GIR230FR, GIA2000, GIR2002)
Handheld instrument
Display / Controller
FHK - Ryton - xx FHKU - Arnite - xx FCM - 6 (2,5 l/min)
General: Product-ID: 603120
General: Flow switch incl. DIN plug
• exact measurements of fl uid volumes • highly accurate measurements of liquid media
• long lifetime, higher temperatures • long lifetime, food safe FCM - 3 (6 l/min)
Application: Product-ID: 603121
Application: Flow switch incl. DIN plug
non-alcoholic and alcoholic beverages, chemicals, water, Water and water-like media in machine and equipment
wine, etc. building General:
FCM fl ow switch has been designed to offer a very simple
Logger / EASYBus
FHK - PVDF - xx FHKU - Ryton - xx and safety control against the missing fl ow passage.
• No setting required
General: General: • Easy and fast replacement of the switch head
• Low pressure loss
• all part in contact with medium: made of plastic • all part in contact with medium: made of plastic and • Horizontal and vertical mounting
• adequate for chemical media (request) stainless steel • Liquid applications
• better chemical compatibility than arnite
Application: • higher temperatures Specifications:
chemical industry: products containing tensides, Body: Brass
alkaline products, acids Application:
industry: monitoring of cooling medium circuits of machi- Measuring of low-viscous media, Process connection: G ½”
nes, dosing and consumption quantity measurements cooling, machine and equipment building Sensing element Polypropylen
(Piston):
Specifications: Specifications: Accuracy: ± 15 %
... - 10 ... - 20 ... - 33 ... - 10 ... - 20 ... - 30 ... - 40
Transmitter
Temperature max.: 90 °C
Nozzle*: 1.0 mm 2.0 mm 3.3 mm Nozzle: 1.0 mm 2.0 mm 3.0 mm 4.0 mm Pressure loss : 0.5 bar at max. fl ow rate
Meas. range 0.05 … 0.11 … 0.20 … Meas. range: 0.05 … 0.10 … 0.12 … 0.15 … Flow rate max.: 25 l/min
(l/min)*: 0.50 2.30 5.00 (l/min) 0.50 2.30 5.60 8.30
Weight: 170 g
Number of pulses (pulses/l): Number of pulses: ~ 2063 ~ 988 ~ 565 ~381
Reed contact N.O. / No fl ow condition
FHK-Ryton ~ 2223 ~ 1013 ~ 509 Pressure range, medium viscosity, accuracies, current
supply and output signal see FHK. Contact rating 300 V, 70 VA, 0.5 A
FHK-PVDF ~ 4962 ~ 2078 ~ 1033
Flow connections: 2 x G¼“ A Wiring: Angle plug
Pressure range: max. 20 bar (at 20 °C)
Working temperature: -10 ... +65 °C -10 ... +100 °C Protection class: IP65
Medium viscosity: < 50 cSt.
Housing: FHKU-Arnite FHKU-Ryton Mounting: Horizontal and vertical
Meas. accuracy: ±2 %
Temperature probe
Material: PBT (Arnite) PPS (Ryton) Set point l/min Nominal ON OFF
Repeatability: < 0.25 % FCM - 6 2.5 2.8 1.7
Power supply: 3.8-24 V DC; max. 8 mA Nuzzle: PPS (ryton) (1 and 2 mm) FCM - 3 6 6.3 4.1
1.4305 (3 and 4 mm)
Output signal: Open collector, NPN
Turbine: PVDF PVDF
Flow 2 x G¼“ IG parallel
connections: Magnets: ceramic SrFeO ceramic SrFeO
(in contact with medium)
Working -10 ... +100 °C
temperature: Sealing: silicone silicone
Housing: FHK-Ryton FHK-PVDF Dimensions: 77 x 43 x 61 mm 77 x 43 x 67 mm
Material: PPS (Ryton) PVDF
ARTIKELNUMBERS:
Nuzzle: 1.4305 PTFE
Turbine: PVDF PVDF FHKU - Arnite - 40: Product-ID: 607010
FHKU - Ryton - 10: Product-ID: 605327
Sealing: Viton Viton
FHKU - Ryton - 20: Product-ID: 607920
Simulator
Specifications:
FHK - Ryton - 20: Product-ID: 604443
Nuzzle: D = 10 mm
FHK - Ryton - 33: Product-ID: 605840
FHK - PVDF - 10: Product-ID: 602851 Meas. range: approx. 3 - 26.7 l/min
FHK - PVDF - 20: Product-ID: 604417 Number of pulses: approx. 65 pulses/liter
FHK - PVDF - 33: Product-ID: 606888 Flow connections: 2 x G½“ A
Housing: PPS (Ryton), nozzle: Ryton, sealing: Viton
other specifications see FHKU-Ryton.
135
further information on www.greisinger.de
ROTATIONAL SPEED SENSOR LEVEL TRANSMITTER
Handheld instrument
Display / Controller
EFF-... LC-S45HM...
Rotational speed sensor Level transmitter (brass)
Design types:
- V: magnetic fi eld sensor (magneto-resistive) LC-S44HM...
- H: preloaded hall sensor Level transmitter (brass)
- I: inductive sensor
LC-K52HK...
General: Level transmitter (stainless steel)
The EFFI and EFFU combine a proximity switch with the signal processing to standard Final prices depend on type, see price table below
signals in one device. The scaling of the standard signal output can be done at face.
Programming: General:
- The value for 0 Hz is fi xed: 4 mA or 0 V A magnet equipped fl oat activates a reed chain inside a tube which is connected to
Logger / EASYBus
- For programming the upper output limit (20 mA or 10 V) you have to adjust the max. resistors comparable to a potentiometer. The gapless positioning of the sensors provides
frequency in the system. By connecting two contacts the device is programmed to this a continuous signal with good resolution (up to 10-20 mm) and repeatability.
value. • top assembly
• selectable material combinations
Specifications: • optional: with user-specifi c characteristic (for adjustment to tank design)
3 different measuring principles:
Application:
design type: magnetic fi eld sensor (magneto-resistive)
Sensor suitable for: Water, oil, aggressive substances (only LC-K52K...)
design type: preloaded hall sensor
design type: inductive sensor Specifications:
Sensing distance: 4 mm Tube length: 250 mm, 500 mm, 750 mm, 1000 mm, 1500 mm and 2000 mm
Measuring range: 1 ... 4095 Hz (EFFC: 2000 Hz) Float travel: ..0250 ..0500 ..0750 ..1000 ..1500 ..2000
Sampling interval: periods measurement, output update 50 ms LC-S45M... : 190 mm 440 mm 690 mm 940 mm
Transmitter
-I 4 ... 20 mA
-U 0 ... 10 V Housing: Ms58 Ms58 stainl. steel 1.4571
3. Programming Option:
-P Programmable (Teach-In possible) AV010:
-N non programmable (no teach-in) output signal 0-10 V
Flex:
Transmitter with Flex-head (M12-connection) user-specifi c characteristic possible
Alarm / Protection, Level
Types:
Tube length: ..0250 ..0500 ..0750 ..1000 ..1500 ..2000
LC-S45HM... ● ● ● ●
LC-S44HM... ● ● ●
LC-K52HK... ● ● ● ● ● ●
136
further information on www.greisinger.de
Transmitter
Handheld instrument
HIGHLIGHTS:
WM 500
Display / Controller
Active Power Transmitter
General:
Active-power transmitter WM 500 converts active-power of symmetric 1-3 phase power
supply systems into proportional industry standard signals. Devices without compensating
circuits can be used to measure active-power of phase-angle controlled equipments or
electric motor drives controlled by frequency inverters.
CT 500
Specifications: AC Current Transmitter
Power supply: General:
Supply voltage: 230 V AC ± 10 % or 24 V DC ± 15 % AC current transmitter CT 500 converts true r.m.s. current measuring values of all types
Frequency AC: 47 ... 63 Hz of waveform into industry standard signals for process control systems. For example,
the load current of an frequency converter can be detected and converted. The universal
Logger / EASYBus
Power consumption: < 3 VA
limit interpretation of the inputs and outputs and the wide auxiliary voltage ranges the
Workting temperature: -10 ... +50 °C variety of types in 2 versions.
CE-conformity: EN 55022, EN 60555, IEC 61000-4-4/5
Specifications:
Inputs:
Power supply:
Current: 0 :.. 1 A: Ri = 82 mΩ, over load 2-times, 4-times for max. 5 s
0 ... 5 A: Ri = 10 mΩ, over load 2-times, 4-times for max. 5 s Supply voltage: 85 ... 265 V AC or 10 ... 30 V AC/DC
Frequency range: 45 ... 400 Hz, Crest-factor: 3 Frequency AC: 40 ... 400 Hz
Curve shape: insignifi cant Power consumption: < 3 VA
Voltage: 0 ... 440 V, Ri = .4 kΩ/V, over load max. 700 V Working temperature: -10 ... +60 °C
Frequency range: 45 ... 400 Hz CE-conformity: EN 55022, EN 60555, IEC 61000-4-3/4/5/11/13
Curve shape: insignifi cant, without compensating circuit Input:
Curve shape: sinusoidal, with compensating circuit Current:
Transmitter
End value: adjustable -30 ... 5 % for factory adjustment Terminals: 0 ... 1 / 2 / 3 / 4 / 5 / 6 A AC, over load max. 9 A
Outputs: Voltage/current Bushing connection: 0 ... 10 / 20 / 30 / 40 / 50 / 60 A,
over load max. 90 A, cable diameter max. 8 mm
Current: 0/4 ... 20 mA selectable, burden ≤ 500 Ω
Ri: < 20 mΩ
Burden error: < 0.1 % (RL = 0 ... 200 Ω), < 0.2 % (RL = 0 ... 500 Ω)
Frequency: 40 ... 2000 Hz fundamental wave, 162/3 Hz on request
Voltage: 0/2 ... 10 V selectable, load max. 10 mA
Start value: adjustable ± 5 %
Adjustment: P = U x I x √ 3 x cosφ = 20 mA (10 V)* (* cosφ=1)
End value: adjustable ± 35 %
Rise time (T90): < 500 ms
Output:
Housing:
Current: 0/4 ... 20 mA, selectable, burden ≤ 1 kΩ
Connection: screw terminals, max. 2.5 mm²
Temperature probe
Voltage: 0/2 ... 10 V DC, selectable, load max. 15 mA, short circuit
Protection class: Housing IP30, terminals IP20 acc. to BGV A3 proof (parallel with the voltage output max. 5 mA)
Ordering code: Rise time (T90): ≤ 150 ms
Accuracy: ≤ 0.5 %; single adjustment ≤ 0.2 %
WM500 - 1 - 2 - 3 - 4 - 5 Housing: Polycarbonate, UL94V-0, TS 35 acc. to DIN EN 60715:2001-09
Weight: approx. 200 g
Greisinger
Connection: terminals, max. 2.5 mm²
Protection class: housing IP30, terminals IP20, acc. to BGV A3
1. Power supply system Accessories and spare parts:
1 1-phase KA-VT
3 3-phase terminal cover for measuring voltages >400 V AC
2. Measuring voltage
Ordering code:
Simulator
100 100 V AC
110 110 V AC CT500- 1 - 2
230 230 V AC
400 400 V AC Greisinger
440 440 V AC
3. Measuring current
1. Measuring ranges
1 1 A AC
30 0 ... 1 / 2 / 3 / 4 / 5 / 6 and
5 5 A AC 0 ... 10 / 20 / 30 / 40 / 50 / 60 A AC
Alarm / Protection, Level
137
further information on www.greisinger.de
CURRENT AND VOLTAGE TRANSMITTER AC VOLTAGE TRANSMITTER
Handheld instrument
NEW !
HIGHLIGHTS:
Specifications:
Power supply Specifications:
Supply voltage: 230 V AC ±10 % (47 ... 63 Hz) or 24 V DC ±15 % Power supply
Power consumption: < 3 VA Supply voltage: 85 ... 265 V AC or 10 ... 30 V AC/DC
Working temperature: -10 ... +50 °C Frequency AC: 40 ... 400 Hz
CE-conformity: EN 55022, EN 60555, IEC 61000-4-3/4/5/11/13 Power consumption: <3 VA
Inputs Working temperature: -10 ... +60 °C
Accuracy: ≤ 0.5 % (≤ 0.2 % single adjustment) CE-conformity: EN 55022, EN 60555, IEC 61000-4-3/4/5/11/13
Standard measuring ranges Input
Current: 0 ... 1 A and 0 ... 5 A sinusoidal or DC Voltage AC: 0 ... 100 / 200 / 300 / 400 / 500 / 600 V AC,
overload max. 1200 V max. 5 s
Ri: 20 mΩ (5 A-) or 100 mΩ (1 A-input)
Ri: 720 kΩ
Transmitter
Overload: 2-times, 4-times max. 5 s
Frequency: 40 ... 2000 Hz fundamental wave, 162/3 Hz on request
Voltage
Start value: adjustable ± 5 %
measuring ranges: 0 ... 125 V and 0 ... 250 V AC or DC
End value: adjustable ± 35 %
Ri: 600 kΩ (125 V-) or 1.2 MΩ (250 V-input)
Output
Overload: max. 500 V AC/DC
Current: 0/4 ... 20 mA, selectable, burden ≤ 1 kΩ
Custom measuring ranges
Voltage: 0/2 ... 10 V DC, selectable, load max. 15 mA, short-circuit-
Voltage: end value in range 0.1 ... 400 V AC/DC, Ri 4.8 kΩ/V proof (parallel with the voltage output max. 5 mA)
Overload: 5-times UN, max. 500 V AC/DC Rise time (T90): ≤ 150 ms
Current: end value in range 0.001 ... 5 A AC/DC, Ri 100 mΩ Accuracy: ≤ 0.5 %; single adjustment ≤ 0.2 %
Temperature probe
CVT500- 1 - 2 - 3
1. Measuring ranges
Greisinger 30 0 ... 100 / 200 / 300 / 400 / 500 / 600 V AC
custom range on request
2. Supply voltage
1. Current ranges
0 85 ... 265 V AC
0 not installed (custom measuring range voltage)
5 10 ... 30 V DC
1 / 5 standard device 0 ... 1 A and 0 ... 5 A AC / DC
Alarm / Protection, Level
138
further information on www.greisinger.de
Transmitter
Handheld instrument
HIGHLIGHTS:
HIGHLIGHTS:
• Monitoring of battery voltages 12 V,
• Arithmetic average value measu- 24 V, 48 V or 60 V
ring RMS calibrated (AC) or DC
• Alarm function under-voltage /
NEW ! • Contact function min/max selectable NEW ! over-voltage selectable
• Hysteresis and time delay • Time delay adjustable
adjustable
• Measuring voltage and supply
Display / Controller
voltage are identical
Logger / EASYBus
Specifications: If the voltage exceeds the limit value + hysteresis, the relay will be activated.
Power supply Over-voltage:
The relay switches on, if the voltage exceeds the limit value and if the delay time ran off.
Supply voltage: 230 V AC ±10 % (47 ... 63 Hz) or 24 V DC -30/+40 % If the voltage falls under the limit value - hysteresis, the relay will be deactivated.
Working temperature: -10 ... +50 °C (-25 °C ... +70 °C on request)
CE- conformity: EN 55022, EN 60555, IEC 61000-4-3/4/5/11/13 Specifications:
Inputs Power supply
Scale error: ≤ 2 % Battery voltage: 12 V, 24 V, 48 V or 60 V DC, -30 ... +40 %
Standard ranges Current consumption: 14 mA (24 mA at 12 V type) with activated relay
Current: 0 ... 1 A and 0 ... 5 A AC (sinusoidal) or DC Working temperature: -10 ... +60 °C
Ri: 20 mΩ (5 A input) or 100 mΩ (1 A input) CE- conformity: EN 50022, EN 60555, IEC 61000-4-4/5/11/13 vibration,-
shock- and jolt-inspection acc. to IEC 68-2-6/27/29
Overload: 2-times, 4-times for max. 5 s
Measuring input/measuring range
Transmitter
Voltage: 0 ... 125 V and 0 ... 250 V sinusoidal or DC
12 V: 11 ... 14 V
Ri: 600 KΩ (125 V input) or 1.2 MΩ (250 V input)
24 V: 22 ... 28 V
Overload: max. 300 V AC/DC
48 V: 44 ... 56 V
Custom ranges
60 V: 55 ... 70 V
Voltage: end value in the range 0.05 ... 400 VAC/DC
Scale error: ≤2 %
Ri: 4.8 kΩ/V
Output
Overload: 5-times nominal voltage, max. 500 V AC / DC
Relay SPDT: 250 VAC < 250 VA < 2 A; 300 V= < 50 W < 2 A
Current: end value in the range 0.001 ... 5 A AC/DC
Alarm function: under-voltage/over-voltage selectable
Ri: = 100 mΩ ÷ (measuring range [A])
Hysteresis: 2 ... 16 % adjustable (related to the nominal battery voltage)
Temperature probe
Overload: 2-times, 4-times for max. 5 s
Time delay: in 2-steps switch selectable 1 ... 60 s or 5 ... 300 s adjustable
Output
Housing: standard case polycarbonate 8020 UL 94 V-1 acc. to DIN EN
Relay SPDT: 250 VAC < 250 VA < 2 A; 100 V= < 50 W < 1 A 60715:2001-09
Switching function: min. / max. selectable Weight: approx. 100 g
Hysteresis: 1 ... 25 % Protection class: Housing IP30, terminal IP20, (BGV A3)
Time delay: 0.1 ... 8 s Connection: screw terminals, max. 2.5 mm²
Housing
Protection class: Housing IP30, terminals IP20, (BGV A3) Ordering code:
Connection: screw terminals, max. 2.5 mm²
BW500- 1 - 2 - 3
Ordering code:
Greisinger
CVG500- 1 - 2 - 3
Simulator
139
further information on www.greisinger.de
ISOLATING SIGNAL CONVERTER UNIVERSAL ISOLATING AMPLIFIER
Handheld instrument
HIGHLIGHTS:
sensors. switches.
Specifications: Specifications:
Power supply Auxiliary power
Supply voltage: 100 ... 265 V AC or 10.8 ... 30 V AC/DC Auxiliary voltage: 18 ... 30V DC
Frequency AC: 47 ... 63 Hz Power consumption: < 0.5 VA
Power consumption: < 3.5 VA Conformity: CE, Directive 2004/108/EG
Working temperature: -10 ... +60 °C EMC: DIN EN 61326-1: 2013-07, Class A
CE-conformity: EN 55022, EN 60555-2, IEC 61000-4-4/5/11/13 Standards: DIN EN 61010-1: 2011-07, DIN EN 61010-2: 2011-07
Inputs Rated voltage: 300 V AC/DC in accordance with DIN EN 61010-1
Current: 0/4 ... 20 mA selectable, Ri = 25 Ω, overload max. 100 mA Test voltage: 3 kV AC, 50 Hz, 1 min
Voltage: 0/2 ... 10 V DC selectable, Ri approx. 40 kΩ, overload max. Input / Output / Auxiliary power
Transmitter
Max. overload 32 V AC/DC in accordance with DIN EN
model 11: < 100 μs, max. frequency 1 kHz 61010-2-30
Accuracy: ≤ 0.2 % (single range adjustment ≤ 0.1 %) Output
Housing: standard case polycarbonate 8020 UL94V-1 acc. to DIN EN Current output: Switchable, 0 ... 20 mA or 4 ... 20 mA. Load < 150 Ω
60715:2001-09
Step response: 40 ms
Weight: approx. 200 g
Standard error: < 0.2 % of fi nal value
Connection: screw terminals, max. 2.5 mm²
Temperature < 0.01 % / K
Protection class: Housing IP30, terminals IP20 acc. to BGV A3 coefficient:
Ordering code: Housing
Material: Polyamide (PA) 6.6, UL94V-0
1 - 2 - 3 Weight: 91 g
Protection rating: Housing IP30, terminals IP20 BGV A3
Greisinger Colour: light grey
Simulator
3. Supply voltage
0 100 ... 265 V AC
5 10.8 ... 30 V AC/DC
140
further information on www.greisinger.de
Transmitter
Handheld instrument
HIGHLIGHTS: HIGHLIGHTS:
NEW !
• 1 or 2 channel version • Universal input for unit signals,
• Safe galvanic isolation between input / • Pt100, thermocouple, potentiometer, switchable via
output / auxiliary voltage NEW ! front-side DIP switch
• Functional safety up to SIL2 EN61508 • 2-colour illuminated scales for limit value adjustment,
colour depends on switch status
• Inputs for switching contacts, Namur
initiators, or optocouplers
Display / Controller
TS125 und TS225 colour depends on switch status
Switch amplifi er
General: GS125
Switch amplifi ers of the series TS 125 and TW 255 are used in switch cabinets for the Limit value switch
conversion and isolation of digital switching signals, as well as in explosion-prone areas.
The devices are available in one- or two-channel versions.
General:
Passive sensors, such as switching contacts, Namur initiators, or passive electronic Limit value switches of the series GS125 are used in switch cabinets for process moni-
outputs of third-party devices, can be connected to the intrinsically safe inputs. The toring or for simple process regulation. Both temperatures and derived variables such as
TS125 series in 12.5 mm wide carrier rail housing offers relay outputs with output make voltage, current and resistance are used as control signals. In the process, 1 or 2 limit
circuit. The TW225 series in 22.5 mm wide carrier rail housing offers relay outputs with values can be monitored. For assignment of the measuring unit to the scale labelling,
changeover function. The plug-in terminal strips enable simple and time-saving wiring. 24 transparent adhesive labels are supplied. They can be glued between the adjusting
Logger / EASYBus
The confi guration is also quick and easy with the front DIP switches. wheels on the front panel.
Specifications: Specifications:
Auxiliary voltage: 20 ... 125 VDC and 20 ... 250 VAC, (47 ... 63 Hz), max.1.5 W Measurement inputs Switchable via DIP switch
Auxiliary voltage: 24 V DC +/-15 % max. 1.5 W Unit signals: 0/2 ... 10 V, 0/4 ... 20 mA
Test voltage: 3kV AC between input / output / auxiliary voltage Potentiometer: 500 Ω ... 20 kΩ
Working temperature: -10 ... +60 °C Pt100: -50 ... +50 °C, 0 ... 50 °C, 0 ... 100 °C, 0 ... 150 °C,
0 ... 200 °C, 0 ... 300 °C, 0 ... 500 °C
Storage temperature: -20 ... +80 °C
Thermocouple: FeCuNI, Type J: 0 ... 250 °C, 0 ... 500 °C
Air humidity: 10 ... 90 % (non-condensing)
NiCrNi, Type K : 0 ... 500 °C, 0 ... 750 °C, 0 ... 1000 °C
Measuring inputs (in accordance with EN60947-5-6 Namur) PtRhPt, Type S: 0 ... 1500 °C
Open circuit voltage: approx. 8 V Wide-range power supply:
Short circuit voltage: approx. 8 mA 24 V power supply
Transmitter
Switching points: inactive <= 1.2 mA, active >= 2.1 mA, hyst. < > 0.5 mA Rated voltage: 253 V AC
Error recognition: Wire break: <0.2 mA, ahort circuit: >7 mA Test voltage: 3 kV AC between input/relay output/auxiliary voltage
Relay outputs: Working temperature: -10 ... +60 °C
Switching voltage: <250 V AC <2 A <500 VA, <125 V DC <0.2 A <25 W, Storage temperature: -20 ... +80 °C
< 30 V DC <2 A <60 W
Air humidity: 10 ... 90 % (non-condensing)
Switching frequency: max. 5 Hz
Relay outputs
Delay: max. 30 ms
Switching voltage: <250 V AC <2 A <500 VA, <125 V DC <0.2 A <25 W,
Housing: <30 V DC <2 A <60 W
Dimensions (W x D x H): TS125: 12.5 x 114 x 108 mm, TS225: 22.5 x 114 x 108 mm Switching frequency: max. 5 Hz
Temperature probe
Protection rating: IP20 Switching hysteresis: approx. 1 %
Terminals: 0.2 ... 2.5 mm², AWG 24 ... 14, removable coded terminals Functional safety: SIL2 in accordance with EN61508
Explosion protection: specifi c data on request (specifi c data available on request)
Functional safety: SIL2 in accordance with EN61508 Setpoint setting: Scale precision: 2 %
Actual value output: 4 ... 20 mA, burden max. 120 Ω, no galvanic isolation from the
Ordering code: input signal
Greisinger GS - 1 - 2 - 3 - 4
Greisinger
1. Device version
Simulator
125L Housing width 12.5 mm, Relay NO contacts, Auxiliary
voltage 24 V DC +/- 15 % 1. Device version
125M Housing width 12.5 mm, Relay NO contacts, Wide-range 125L Power supply 24 V DC +/- 15 %
mains adapter 125LP Power supply 24V DC +/-15% with carrier rail bus
225M Housing width 22.5 mm, Relay changeover contacts, connection *)
Wide-range mains adapter 125M Wide-range power supply 20 ... 125 VDC / 20 ... 253 V AC
2. Explosion protection 2. Limit value contacts
00 Installation of the device TV125L in Zone 2 permitted, in 1 1 relay (changeover contact)
accordance with ATEX ignition protection rating ‚n‘
2 2 relays (universal connection)
Alarm / Protection, Level
Ex With installation of the devices outside the Ex area:
3 2 relays (potential-free n.o. contacts)
Inputs intrinsically safe in accordance with ATEX ignition
protection rating ‚ia‘ for Zones 0 and 20. The device 3. Actual value output
TS125L may be installed in Zone 2 in accordance with 0 not provided
ATEX ignition protection rating ‚ic‘.
1 Output 4 ... 20 mA
3. Number of channels
4. Options
1 Single channel
00 No options
2 Dual channel
01 Push-in terminals (plug-in)
F Single channel with additional error relay or parallel
relay *) see also separate information sheet Power-Rail
141
further information on www.greisinger.de
AC CURRENT TRANSMITTER ANALOG FREQUENCY TRANSMITTER
Handheld instrument
HIGHLIGHTS:
NEW ! NEW !
HIGHLIGHTS: • Output frequency from 0 ... 0.01
Hz / 20 kHz programmable
• 1- and 2-channel device
• Inputs for 0/4 ... 20 mA,
• Measuring ranges 0 ... 1 A /
0/2 ... 10 V DC
0 ... 5 A AC
• Teach-in programming for analog
• Arithmetic average value measure-
start- and end value
Display / Controller
CT500P AF500
AC Current Transmitter Analog Frequency Transmitter
General: General:
Logger / EASYBus
The transmitter converts AC current from 0 ... 1 A or 0 ... 5 A to the proportional standard Analog frequency transmitter AF 500 converts standard industry signals 0/4 ... 20 mA or
signal 4 ... 20 mA. The measurement method is calibrated an arithmetic averaging on 0/2 ... 10 V DC into a proportional frequency. The output frequency is programmable with
RMS. The CT 500 P operates like an 2-wire transmitter, which is supplied from the rotary switches at the case side.
measuring device (e.g. SPS input circuit board). Small housing width allows a space-
saving installation. Specifications:
Power supply
Specifications:
Supply voltage: 230 V AC ±10 % or 24 V DC ±15 %
Power supply
Frequency AC: 47 ... 63 Hz
Loop voltage: 14 ... 30 V DC
Power consumption: < 3 VA
Working temperature: -10 ... +60 °C
Working temperature: -10 ... +60 °C
CE-conformity: EN55022, EN60555, IEC61000-4-4/5
CE-conformity: EN 55022, EN 60555, IEC 61000-4-4/5/11/13
Input: 1- or 2-channels
Input
Current: 0 ... 1 A or 0 ... 5 A AC, overload max 10 A
Current: 0/4 ... 20 mA, switch selectable
Transmitter
Ri: < 20 mΩ
- internal resistance: Ri = 51 Ω
Frequency: 45 ... 400 Hz fundamental wave, 162/3 Hz on request
Voltage: 0/2 ... 10 V DC, switch selectable
End value: adjustable ± 5 %
- internal resistance: Ri = 20 kΩ
Output
Start value: via software programmable 0 ... +25 %
Current: 4 ... 20 mA, burden Rmax. = (UB - 14 V) ÷ 20 mA
End value: via software programmable -15 ... +10 %
Rise time (T90): ≤ 1 s
Output
Accuracy: ≤ 0.2 %
Transistor: max. 30 V DC, load max. 30 mA
Housing Polycarbonate, UL94V-0 TS 35 acc. to DIN EN 60715:2001-09
- Frequency range: 0 ... 0.01 Hz, 0 ... 20 kHz duty cycle 0.5
Weight: approx. 200 g
Relay SPDT: 250 V AC < 250 VA < 2 A, 100 V = < 50 W < 1 A
Temperature probe
Connection: screw terminals, max. 2.5 mm²
- Frequency range: 0 ... 0.01 Hz, 0 ... 9.9 Hz, duty cycle 0.5
Protection class: Housing IP30, terminals IP20 acc. to BGV A3
Accuracy: 0.1 % of the end value
Accessories and spare parts: Housing: Polycarbonate, UL94V-0 TS 35 acc. to DIN EN 60715:2001-09
KA-500 Weight: approx. 140 g
terminal cover for measuring voltages > 400V AC Connection: screw terminal, max. 2.5 mm²
Ordering code: Protection class: Housing IP30, terminals IP20 acc. to BGV A3
Ordering code:
CT500P- 1 - 2 - 3
Greisinger
AF500- 1 - 2 - 3
Greisinger
Simulator
1. Number of channels
1 1. Measuring range
2 10 0/4 ... 20 mA, 0/2 ... 10 V DC
2. Input direct connection / via transformer output frequency from 0 ... 0.01 up to 20 kHz
0 1 A 2. Supply voltage
5 5A 0 230 V AC ±10 %
3. Options 5 24 V DC ±15 %
00 without option 3. Options
Alarm / Protection, Level
00 without option
142
further information on www.greisinger.de
Transmitter
Handheld instrument
HIGHLIGHTS:
Display / Controller
• Integrated transmitter supply
FT500 pH40
Frequency Analog Transmitter pH Head-Transmitter
General: General:
Frequency transmitter FT 500 are used to convert an impulse frequency range into The head transmitter PH 40 provides a cost-effective way of pH measurement. It is sim-
industry standard signals. The transmitter accepts impulses from proximity switch, ply plugged on the pH sensor with „Überwurfmutter“. The electrical connection is via the
contact switch, light barriers and Namur proximity switches. Start- and end value will be 8-pole. Circular Connectors. Depending on the execution is the signal from the pH
programmed with 5 rotary switches. The setting of intermediate values occurs at the front sensor issued with either a low output impedance or available as galvanically isolated
trim. Increasing or decreasing output characteristic is therefore programmable. 4 ... 20 mA signal is available.
Logger / EASYBus
Specifications: Specifications:
Power supply Power supply
Supply voltage: 85 ... 265 V AC or 10 ... 30 V AC / DC Supply voltage: 5 ... 30 V DC output 0
Frequency AC: 47 ... 63 Hz 10 ... 30 V DC output 2
Power consumption: < 4 VA Working temperature: -10 ... +60 °C
Working temperature: -10 ... +60 °C Input pH/ORP
CE- conformity: EN 55022, EN 60555, IEC 61000-4-4/5/11/13 Measuring range: -1 ... +15 pH / ± 1500 mV
Input Input resistance: >1012 Ω
Frequency range: 0 ... 0.01 Hz / 20 kHz Output
Pulse cycle Type 1: 1:1 transfer of the pH-signal with low output impedance, error
free measurement up to 100 m
Transmitter
pulse/stop: min. 20 μs (electronic) and min. 5 ms (contacts)
Type 2: 4 ... 20 mA, 2-wire technology in the range -1 ... +15 pH
Start value: programmable 0 ... +25 % depending at 25 °C, zero-point pH 7.0, slope 59.2 mV/pH, not
End value: programmable -15 ... +5 % compensated
Impulse input Accuracy: type 0 = 0.01 %, type 2 = 0.2 %
(Terminals 2, 3): Low-Signal -30 V ... +3 V, High-Signal +10 V ... +35 V Housing
input resistance: Ri > 10 kΩ Material: PVC-U
Transmitter supply Weight: approx. 100 g
(Terminal 1): approx. 20 V DC, 25 mA short circuit current Process connection: S7
Namur input Electrical connection: 8 pole round socket
Temperature probe
(Terminals 4, 5): acc. to DIN 19234, Namur Protection class: IP65
input resistance: approx. 1 kΩ
Accessories and spare parts:
Output
SKM8E-02
Current: 0/4 ... 20 mA selectable, burden ≤ 1 kΩ 2 m IP67, connection cable terminated with 8-pin. Cable socket and open on one side
Voltage: 0/2 ... 10 V DC, load max. 10 mA, short-circuit-proof with ferrules, PU cable
(parallel with current output, 5 mA) SKM8E-05
Accuracy: 0.1 % Measuring end value 5 m IP67, connection cable terminated with 8-pin. Cable socket and open on one side
with ferrules, PU cable
Rise time (T90): < 130 ms
SKM8E-10
Housing Polycarbonate, UL94V-0 TS 35 acc. to DIN EN 60715:2001-
10 m IP67, connection cable terminated with 8-pin. Cable socket and open on one side
09
with ferrules, PU cable
Weight: approx. 140 g
SKM8E-25
Connection: screw terminals, max. 2.5 mm² 25 m IP67, connection cable terminated with 8-pin. Cable socket and open on one side
Protection class: case IP30, terminals IP20, acc. to BGV A3 with ferrules, PU cable
Simulator
Ordering code:
Ordering code:
FT500- 1 - 2 - 3 pH40 - 0 - 2 - 00
Output: -1 ... +15 pH, 1:1 signal transfer
Greisinger pH40 - 2 - 2 - 00
Output: 4 ... 20 mA = -1 ... +15 pH
1. Measuring range
Alarm / Protection, Level
70 0 ... 0.01 Hz up to 20 kHz, output 0/4 ... 20 mA and
0/2 ... 10 V DC
2. Supply voltage
0 85 ... 265 V AC
5 10 ... 30 V AC / DC
3. Options
00 without option
143
further information on www.greisinger.de
CVC-AMPLIFIER TSA-PWR MODULE
Handheld instrument
NEW ! NEW !
Display / Controller
TSA-PWR
TSA-PWR module
General:
CVC-02/0201 The TSA-PWR module is used for control of loads up to a power of 2 W at a current of up
to 200 mA. Depending on the application, the required confi guration must be specifi ed.
CVC-amplifi er
General: Specifications:
The CVC-amplifi er is used for potential-free signal processing and fi ltering of currents. Supply voltage: 24 V DC (10-30 V DC)
For this, two channels per board are available. About pluggable fi lter modules, the signal Power consumption at nominal voltage 100 mA
can be fi ltered in any specifi ed frequency range. For an input current range of ±2 A, the (without sensor / without load)
output voltage is ±1 V. The functionally reliable supply voltage range is 6 ... 18 V DC.
Electrical isolation (3-way isolation) 1000 V DC
Logger / EASYBus
Output – Voltage
Output – Current
Output range ± 1 V
Output range (A5 / A6) ± 200 mA / 0 ... 200 mA
max. Current output ± 10 mA
Max. load current
short circuit proof yes
(U output) ± 200 mA
Residual ripple @
Residual ripple @
fg = 1 kHz typ. 10 mVpp
fg = 1 kHz typ. 10 mVpp
fg = 10 kHz typ. 15 mVpp
fg = 10 kHz typ. 15 mVpp
Environmental temperature: 0 ... +50 °C
Environmental temperature 0 ... 50 °C
Plug-in filter 10, 30, 50, 100, 300, 500,
Plug-in filter 10, 30, 50, 100, 300, 500, 1 k, 3 k, 5 k,
Standard frequencies in Hz: 1 k, 3 k, 5 k, 10 k
Standard frequencies in Hz 10 k
Connectivity Spring-loaded terminals
Housing: ME 22.5: 22.5 x 99 x 114.5 mm (B x H x T)
Temperature probe
02 2 Channels V2 0 ... 10 V
2. Input A1 ± 20 mA
02 ± 2 A A2 0 ... 20 mA
3. Output A3 4 ... 20 mA
01 ± 1 V 3. Output filter frequencies (Hz)
4. Output filter frequencies (Hz) XXX Enter standard values: 10, 30, 50, 100, 300, 500,1 k,
XXX Enter standard values: 10, 30, 50, 100, 300, 500, 1 k, 3 k, 5 k, 10 k
3 k, 5 k, 10 k YY Enter non-standard value: 1 ... 30 k
Alarm / Protection, Level
144
further information on www.greisinger.de
Temperature probe
TEMPERATURE PROBE
Handheld instrument
Display / Controller
Logger / EASYBus
GTF 101-N...
GTF 101-5...
GTF 10x-Ex
TF 101 ...
GTF 112
GTF 111
GTT ..
Transmitter
Application:
NiCr-Ni (Type K) ● ● ● ● ● ● ●
NiCrSi-NiSi (Type N) ●
Freely customized probes
(Pt100 / Pt1000) ● ● ● ● ● ● ●
Miniature flat-pin plug ● ● ● ● ● ● ●
Temperature probe
Loose ends ● ● ● ● ● ● ● ●
M12-plug, 4-pol. ● ●
Sensor head ● ●
- Protection ●
Thermo elements ● ●
permanent high
●
Simulator
temperatures
Industrial probes, process
connection without thread ● ● ● ● ● ● ●
Industrial probes, process
connection with thread ● ● ● ●
Hermetically sealed probe ●
●
Alarm / Protection, Level
Self-adhesive probes
Device information:
Catalogue page 146 147 153 148 150 151 154 152 152 156 157
145
further information on www.greisinger.de
STANDARD - JACKET THERMO ELEMENTS NICR-NI NICR-NI, TYPE K
Handheld instrument
HIGHLIGHTS:
ALSO IN TYPE N
AVAILABLE • Same material for contacts and thermo elements
FROM
FLAT-PIN PLUG FREE
THERMAL E.M.V.
Logger / EASYBus
Type: Ø mm EL mm
GTT-05-0150
150
Product-ID: 607542
GTT-05-0250
250
Product-ID: 607543
GTT-05-0500
0.5 500
Product-ID: 607544
GTT-xx-xxxx
Jacket thermo elements NiCr-Ni (type K) complete with miniature fl at-pin plug GTT-05-1000
1000
NST1200 (free from thermal e.m.f.) Product-ID: 607545
GTT-05-1500
Specifications: 1500
Product-ID: 607546
Jacket material: Inconel 600, fl exible - other materials upon request
GTT-10-0150
150
Transmitter
Insulation: highly compressed pure MgO
Product-ID: 607547
Thermo wires: NiCr-Ni, DIN IEC 584, welding insulated (volt-free)
GTT-10-0250
Accuracy: optimum accuracy (cl. 1) = ±1.5 °C or ±0.4 % of measuring 250
Product-ID: 607548
value (Almost double accuracy as compared to class 2.
As a comparison with class 2: ±2.5 °C or ±0.75 % of GTT-10-0500
1.0 500
measuring value) Product-ID: 607549
Temperature -220 ... +1150 °C GTT-10-1000
application range: (Probe tip and front part; wire outlet: max. 200 °C)
1000
Product-ID: 607550
(Accuracy class 1 applicable from -40 ... +1000 °C)
GTT-10-1500
1500
Recommended upper temperature limit for continuous use: Product-ID: 607551
GTT-15-0150
Temperature probe
Product-ID: 607558
GTT-30-0500
3.0 500
Product-ID: 607559
GTT-30-1000
1000
Product-ID: 607560
GTT-30-1500
1500
Product-ID: 607561
GTT-60-0150
150
Alarm / Protection, Level
Product-ID: 607562
GTT-60-0250
250
Product-ID: 607563
GTT-60-0500
6.0 500
Product-ID: 607564
Special sizes upon request.
GTT-60-1000
1000
Product-ID: 607565
All thermo elements accuracy class 1 GTT-60-1500
(Almost double accuracy than class 2!) 1500
Product-ID: 607566
146
further information on www.greisinger.de
Temperature probe
Handheld instrument
HIGHLIGHTS:
• Flexible (the smaller the diameter the smaller the bending radii)
Display / Controller
outer jacket)
D
MECHANICALLY SOUN
Ø8 bei
D=6
Ø5
D
Logger / EASYBus
Type: Ø mm EL mm
EL ~50 L
GTF101-5-05-0150
L = 1 m, for other cable length or other 150
Product-ID: 607596
accessories p.r.t. accessories
GTF101-5-05-0250
250
Product-ID: 607597
GTF101-5-05-0500
0,5 500
Product-ID: 607598
GTF101-5-xx-xxxx GTF101-5-05-1000
2. Jacket thermo elements NiCr-Ni (type K) complete with cable sleeve and 1 m 1000
Product-ID: 607599
silicone cable (compensation line), loose wire ends
GTF101-5-05-1500
Specifications: 1500
Product-ID: 607600
Jacket material: Inconel 600, fl exible - other materials upon request and GTF101-5-10-0150
150
Transmitter
against upcharge Product-ID: 607601
Insulation: highly compressed pure MgO
GTF101-5-10-0250
Thermo wires: NiCr-Ni, DIN IEC 584, welding insulated (volt-free) 250
Product-ID: 607602
Accuracy: optimum accuracy (cl. 1) = ±1.5 °C or ±0.4 % of measuring GTF101-5-10-0500
value (Almost double accuracy as compared to class 2. 1,0 500
Product-ID: 607603
As a comparison with class 2:
±2.5 °C or ±0.75 % of meas. value) GTF101-5-10-1000
1000
Connecting cable: silicone compensation line, 1 m long (max. 200 °C), loose Product-ID: 607604
ends. (Longer line or other material against upcharge) GTF101-5-10-1500
1500
Temperature -220 ... +1150 °C (Probe tip and front part; wire outlet: Product-ID: 607605
application range: max. 200 °C, for cable p.r.t. accessories) GTF101-5-15-0150
Temperature probe
(Accuracy class 1 applicable from -40 ... +1000 °C 150
Product-ID: 607606
Recommended upper temperature limit for continuous use: GTF101-5-15-0250
250
Ø 0.5 1.0 1.5 Product-ID: 607607
°C 700 700 920 GTF101-5-15-0500
1,5 500
Product-ID: 607608
Accessories and spare parts: GTF101-5-15-1000
Clamping screw connection 1000
Product-ID: 607609
Ø 1.5, 3.0 or 6.0 mm, see accessories
GTF101-5-15-1500
NST1200 „K“ 1500
Product-ID: 607610
Product-ID: 602566
Prefabricated fl at connector GTF101-5-30-0150
150
Product-ID: 607611
GTF101-5-30-0250
250
Simulator
Product-ID: 607612
GTF101-5-30-0500
3,0 500
Product-ID: 607613
GTF101-5-30-1000
1000
Product-ID: 607614
GTF101-5-30-1500
1500
Product-ID: 607615
GTF101-5-60-0150
150
Alarm / Protection, Level
Product-ID: 607616
GTF101-5-60-0250
250
Product-ID: 607617
GTF101-5-60-0500
6,0 500
Special sizes and other connection cables see Product-ID: 607618
industry temperature probe type GTF 101 K GTF101-5-60-1000
1000
Product-ID: 607619
All thermo elements accuracy class 1 GTF101-5-60-1500
(Almost double accuracy than class 2!) 1500
Product-ID: 607620
147
further information on www.greisinger.de
INDUSTRY - TEMPERATURE PROBE
Handheld instrument
The GTF 101 is a temperature probe that can be fully tailored according to customers‘ The GTF 101 is a temperature probe that can be fully tailored according to customers‘
requirements. The robust GTF 101 is especially suited for applications at high permanent requirements. The robust GTF 101 is especially suited for applications at high permanent
temperatures and pressures in air, gases or liquids. The temperature is measured with temperatures and pressures in air, gases or liquids. The temperature is measured with
resistance temperature sensors (Pt100 or Pt1000) resistance temperature sensors (Pt100 or Pt1000)
Specifications: Specifications:
Probe diameter D: 3 mm, 4 mm, 5 mm, 6 mm, 8 mm, Probe diameter D: 3 mm, 4 mm, 5 mm, 6 mm, 8 mm,
other diameters upon request other diameters upon request
Cable sleeve: for probe diameters D 3 mm, 4 mm, 5 mm, 6 mm, 8 mm: Accuracy: DIN class B, DIN class A, 1/3 DIN class B, 1/10 DIN class B
there is a cable sleeve Ø 5 mm x 50 mm in addition to the Tube material: V4A stainless steel (1.4404 or 1.4571)
fi tting length
for probe diameters D 6 mm and MB3 or MB4: Ordering code:
there is a cable sleeve Ø 8 mm x 35 mm with taper to
Logger / EASYBus
Ø 5 mm x 17 mm in addition to the fi tting length
Note: GTF 101 P- OKH 1 2 3 4 5 6 7 8
The temperature of the cable sleeve must not exceed the
permitted temperature of the cable.
Accuracy: DIN class B, DIN class A, 1/3 DIN class B, 1/10 DIN class B 1. Sensor element
Tube material: V4A stainless steel (1.4404) P Pt100
T Pt1000
Ordering code:
2. Sensor element connection
2L 2-wire
GTF 101 P 1 2 3 4 5 6 7 8 3L 3-wire
4L 4-wire
3. Accuracy
1. Sensor element A DIN class A
Transmitter
P Pt100 B DIN class B (standard)
T Pt1000 D 1/3 DIN class B
2. Sensor element connection Z 1/10 DIN class B (validity area: -50 ... +100 °C)
2L 2-wire 4. Measuring range MB
3L 3-wire MB1 -50 ... +200 °C
4L 4-wire MB2 -50 ... +250 °C (only with Tefl on or glass silk cable)
3. Accuracy MB3 -50 ... +400 °C (only with glass silk cable)
A DIN class A MB4 -200 ... +250 °C (only with Tefl on cable)
B DIN class B (standard) MB5 -20 ... +105 °C (only with PVC-cable)
D 1/3 DIN class B 5. Probe diameter D
Temperature probe
(surcharge per 1 m cable length L)
Lxx any length in m
G glass silk cable up to max. 400 °C
8. Type of cable
(surcharge per 1 m cable length L)
P PVC cable up to max. 105 °C
(surcharge per 1 m cable length L)
S silicone cable up to max. 200 °C
(surcharge per 1 m cable length L)
T Tefl on cable up to max. 250 °C
(surcharge per 1 m cable length L)
G glass silk cable up to max. 400 °C
(surcharge per 1 m cable length L)
Special lengths, special sheath materials, etc. upon request.
148
further information on www.greisinger.de
Temperature probe
Handheld instrument
GTF 101 K GTF 101 K-OKH
Temperature probe Temperature probe
General: General:
Display / Controller
The GTF 101 is a temperature probe that can be fully tailored according to customers‘ The GTF 101 is a temperature probe that can be fully tailored according to customers‘
requirements. The robust GTF 101 is especially suited for applications at high permanent requirements. The robust GTF 101 is especially suited for applications at high permanent
temperatures and pressures in air, gases or liquids. The temperature is measured with temperatures and pressures in air, gases or liquids. The temperature is measured with
thermocouple wires (NiCr-Ni). thermocouple wires (NiCr-Ni).
Specifications: Specifications:
Sensor element: NiCr-Ni (type K) Sensor element: NiCr-Ni (type K)
Measuring range: -200 ... +1150 °C Probe diameter D: 3 mm, 5 mm, 6 mm,
Probe diameter D: 1.5 mm, 3 mm, 6 mm other diameters upon request
other diameters upon request Accuracy: class 1
Cable sleeve: for probe diameters D 0.5 mm, 1 mm, 1.5 mm, 3 mm: Tube material: V4A stainless steel
there is a cable sleeve Ø 5 mm x 50 mm in addition to the
Logger / EASYBus
fi tting length Ordering code:
for probe diameters D 6 mm:
there is a cable sleeve Ø 8 mm x 35 mm with taper to
Ø 5 mm x 17 mm in addition to the fi tting length GTF 101 K 1 2 3 4 5
Note:
The temperature of the cable sleeve must not exceed the
permitted temperature of the cable. 1. Probe diameter D
Accuracy: class 1 D30 3.0 mm only with Tefl on cable
Tube material: Inconel 600 D50 5.0 mm
D60 6.0 mm
Ordering code: Dxx other diameter in mm
2. Fitting length EL
GTF 101 K 1 2 3 4 0050 50 mm
0100 100 mm
Transmitter
0150 150 mm
1. Probe diameter D 0250 250 mm
D15 1.5 mm 0500 500 mm
D30 3.0 mm 1000 1000 mm
D60 6.0 mm xxxx any EL in mm (e.g.: 0100 = 100 mm)
Dxx other diameter in mm 3. Measuring range
2. Fitting length EL MB1 -50 ... +200 °C
0100 100 mm MB2 -50 ... +250 °C only with Tefl on or glass silk cable
0150 150 mm MB3 -50 ... +400 °C only with glass silk cable
0250 250 mm 4. Cable length L
Temperature probe
0500 500 mm L01 1 m silicone cable (standard)
1000 1000 mm Lxx any length in m (e.g.: L03 = 3 m)
xxxx any EL in mm (e.g.: 0100 = 100 mm) 5. Type of cable
3. Cable length L S silicone cable up to max. -50 ... +200 °C (standard)
L01 1 m silicone cable (standard) (surcharge per 1 m cable length L)
Lxx any length in m (e.g.: L03 = 3 m) T Tefl on cable up to max. -200 ... +250 °C
(surcharge per 1 m cable length L)
4. Type of cable
G glass silk cable up to max. -50 ... +400 °C
S silicone cable up to max. -50 ... +200 °C (standard)
(surcharge per 1 m cable length L)
(surcharge per 1 m cable length L)
T Tefl on cable up to max. -200 ... +250 °C
(surcharge per 1 m cable length L)
G glass silk cable up to max. -50 ... +400 °C
(surcharge per 1 m cable length L)
Simulator
Standard types see standard jacket thermo element GTF 101-5-xx-xxxx.
Alarm / Protection, Level
149
further information on www.greisinger.de
INDUSTRY - TEMPERATURE PROBE
Handheld instrument
HIGHLIGHTS:
• very robust
Display / Controller
T4 Pt1000 (4-wire)
Specifications: K NiCr-Ni
Sensor element: Pt100 (2- / 3- or 4- wire) 2. Accuracy
Pt1000 (2- / 3- or 4- wire) 1 class 1 only for NiCr-Ni
NiCr-Ni A DIN class A only for Pt100 / Pt1000
Accuracy (standard): Pt100 / Pt1000: DIN class B B DIN class B (standard) only for Pt100 / Pt1000
NiCr-Ni: class 1 D 1/3 DIN class B only for Pt100 / Pt1000
Tube material: V4A (1.4404) Z 1/10 DIN class B only for Pt100
(validity area: -50 ... +100 °C)
Thread material: stainless steel
3. Measuring range
Connection cable: standard: silicone compensation line, loose ends, MB1 -50 ... +200 °C
length: 1 m (up to max. 200)
MB2 -50 ... +400 °C
MB3 -50 ... +600 °C
Transmitter
0150 150 mm
0250 250 mm
0500 500 mm
1000 1000 mm
xxxx any length in mm (e.g. 0700 = 700 mm)
6. Thread
G1 G ½ (standard)
G2 G¼
G5 G ⅜
M5 M5 max. D = 3.0 mm
M6 M6 max. D = 3.0 mm
M8 M8 max. D = 5.0 mm
M0 M10 max. D = 6.0 mm
Simulator
(surcharge per 1 m cable length L)
G glass silk cable up to max. -50 ... +400 °C
(surcharge per 1 m cable length L)
150
further information on www.greisinger.de
Temperature probe
Handheld instrument
Connection head (aluminum head type B)
G1/2"A V4A
Display / Controller
Sensor tube material:
Pt100, Pt1000, NiCr-Ni „non bendable“ = materialV4A (1.4404)
NiCr-Ni „bendable“ = Inconel 600
Logger / EASYBus
GTF 103
Temperature probe
GTF 103 1 2 3 4 5 6 7 8 9 10 11 12 13
Transmitter
(Pt100 only) xxx other neck tube length
G with ouput signal 4-20 mA, 2-wire, GITT 01 11. Probe diameter
(Pt1000 or NiCr-Ni) 30 3 mm
GV with ouput signal 0 ... 10 V, 3-wire, T03 BU 40 4 mm
(Pt100 only) 60 6 mm
Technical specifi cations Transmitter T03 BU, RT 80 8 mm
420,GIT01, see chapter Transmitters
xxx other diameter
2. Sensor element
12. Fitting length
P Pt100
0050 50 mm
T Pt1000
0100 100 mm
K NiCr-Ni Typ K
0150 150 mm
Temperature probe
3. Accuracy class
0250 250 mm
B DIN class B (Pt100 or Pt1000)
0500 500 mm
A DIN class A (Pt100 or Pt1000)
xxxx any length in mm (e.g. 0600 = 600 mm)
D 1/3 DIN class B (Pt100 or Pt1000)
13. Measuring range
Z 1/10 DIN class B (only Pt100)
MB1 -50 … +200 °C
(validity area: -50 ... +100 °C)
MB2 -50 … +400 °C
1 class 1 NiCr-Ni type K
MB3 -50 … +600 °C
4. Sensor element connection
MBS other measuring range
2L 2-wire
(Specifi cation required with standard signal)
3L 3-wire
4L 4-wire
5. Connection head
A sensor head made of aluminum (DIN B head)
E sensor head made of stainless steel
Simulator
8. Neck tube
K no neck tube
M with neck tube
9. Size of process connection
G1 G 1/2
G2 G 1/4
G5 G 3/8
M14 M14x1,5
Special designs can be ordered only in written form (fax/letter/email)
xxx other thread
and are excluded from exchange!
151
further information on www.greisinger.de
INDUSTRY - TEMPERATURE PROBE
Handheld instrument
NEW !
connector connector
NEW !
Display / Controller
Specifications: Specifications:
Sensor element: Pt100 or Pt1000 (4-wire) Sensor element: Pt100 or Pt1000 (4-wire)
Temperature range: -50 … +250 °C (probe tip) Temperature range: -50 … +250 °C (probe tip)
Accuracy: Class B, Class A, Class AA, Accuracy: Class B, Class A, Class AA,
Class 1/10 DIN B Class 1/10 DIN B
Logger / EASYBus
M12 connecting cable see page 134 G2 G¼
xxx other threads
6. neck tube
000 No neck tube (only up to 100 °C, only with MB0)
050 50 mm
7. Option
00 without option
Alarm / Protection, Level
152
further information on www.greisinger.de
Temperature probe
Handheld instrument
GTL ...
Probes according to customer specifi cation
Specifications:
Measuring range: -40 ... +200 °C (depending on probe construction)
Sensor: Pt 100
Process connection: M12 / G1/2“ / without thread
Probe head: probe head Ø 59 mm
probe head Ø 18 mm Long (with transmitter)
probe head Ø 18 mm Short (without transmitter)
Material: sensor head: V2A, protection tube and peak: V4A
Display / Controller
Probe length: 50, 100, 150, 250 or according to customer specifi cation (in mm)
Diameter: Ø 6 mm without contraction
Ø 4 mm without contraction
Ø 6 mm with offset probe peak Ø 3 mm
Response Time: Ø 6 mm: T90 ≤ 8.0 s
Ø 4 mm: T90 ≤ 6.5 s
Ø 3 mm: T90 ≤ 1.5 s
Protection class: IP69K / IP67
Option:
- Neck tube
- Electr. connection:
fi xed cable (PG) or M12-plug
Logger / EASYBus
- Transmitter
- Higher accuracy (1/3 DIN cl. B or 1/10 DIN cl. B)
- Display of temperature
Transmitter
1300 °C)
HIGH TEMPERATURES (PERMANENTLY UP TO
UREMENTS HIGH TEMPERATURES EMENTS
UR
COST-EFFICIENT MEAS COST-EFFICIENT ME AS
Temperature probe
GTF101-N03250 GTF101-N06250
Product-ID: 602770 Product-ID: 602769
-50 ... +1300 °C, (short-term up to 1330 °C), FL = 250 mm -50 … +1300 °C, (short-term up to 1330°C), FL = 250 mm;
more robust design with thicker protective cover
GTF101-N03500
Product-ID: 602771 GTF101-N06500
as above, but FL = 500 mm Product-ID: 607634
as above, but FL = 500 mm
GTF101-N031000
Product-ID: 602772 GTF101-N061000
as above, but FL = 1000 mm Product-ID: 607635
General: as above, but FL = 1000 mm
Measuring probe Ø 3 mm General:
Simulator
Specifications:
Response time T90: approx. 5 s
Probe tube: nickel-chromium-based stainless steel Ø 3 mm
Cable: 1 m silicone cable, loose ends
153
further information on www.greisinger.de
INDUSTRIAL TEMPERATURE PROBES INDUSTRIAL TEMPERATURE PROBES (ATEX 100)
Handheld instrument
FL
FL HL
GTF 200 Pt100
Product-ID: 600017
-50 ... +200 °C, Pt100, 4-wire
Display / Controller
Upcharges:
Sensors:
Pt100 / Pt1000; mineral insulated element, 4-wire:
meas. range: -200 °C ... +100 °C (600 °C - with neck tube), DIN class B
Type K or N, mineral insulated thermocouple:
meas. range: -200 °C ... +100 °C (900 °C - with neck tube), class 1
Transmitter
Probe length:
up to 100mm (without upcharge)
upcharge per further starting 100 mm
Neck tube length:
without (without upcharge)
upcharge per starting 100 mm
Probe diameter:
GRO 200 Pt100 3 mm, 4 mm, 5 mm, 6 mm or 8 mm (without upcharge)
Product-ID: 600012 Cable:
temperature probes silicone cable, standard lenght 1 m
upcharge per further starting m cable
GRO 200 Pt1000
Temperature probe
Ambient temperature:
Product-ID: 600013 -20 ... +60 °C (protection type „e“) or -20 ... +80 °C (protection type „i“)
temperature probes, -50 ... +200 °C, DIN class B, 4-wire Type of protection:
„i“ : intrinsic safety (without upcharge)
GRO 200 K „e“: increased safety
Product-ID: 600011 Potentially explosive atmospheres:
temperature probes, -50 ... +200 °C, NiCr-Ni (Type K) suitable for zone 1, zone 2, zone 21, zone 22
Specifications: Clamping ring screw connection:
available at M8x1, M10x1, G1/4“ and G1/2“ for diameter 3 mm, 6 mm or 8 mm.
Sensor body: made of aluminium
Please refer to page 158
Probe: can be mounted with cable clamp or similar constructions to
To determine exact order name ask for our type list. Download via homepage possible
pipes (any diameter)
(Products -->Ex-Protection-->Temperature probes).
Cable: silicone, approx. 2 m
For faster heat exchange we suggest our
Simulator
154
further information on www.greisinger.de
Temperature probe
Handheld instrument
FL
FL HL
FL HL
FL
Display / Controller
with neck tube, for temperatures >100 °C without neck tube, for temperatures ≤100 °C
LY EXPLOSIVE
FOR ALL POTENTIAL P II
E EQUIPMENT-GROU
ATMOSPHERES OF TH
N (I) OR (E)
WITH THE PROTECTIO
Logger / EASYBus
-200 °C ... +100 °C (without neck tube) -200 °C ... +100 °C (without neck tube)
-200 °C ... +900 °C (with neck tube) -200 °C ... +900 °C (with neck tube)
General: General:
Readily assembled voltage free temperature probe of stainless steel with connection Readily assembled voltage free temperature probe of stainless steel connection head and
cable. The sensor inset is not exchangeable. Thread is welded or brazed to the probe. clamping block. The sensor inset is exchangeable. Thread is welded or brazed to the pro-
be. Mounting is done via clamping ring fi tting or thread welded / brazed to the probe tube.
Upcharges: The connection head is also suitable to carry a head transmitter.
Sensors:
Pt100 / Pt1000, mineral insulated element, 4-wire: Upcharges:
meas. range: -200 °C ... +100 °C (600 °C - with neck tube), DIN cl. B Sensors:
type K or N, mineral insulated thermocouple: Pt100 / Pt1000; mineral insulated element, 4-wire:
meas. range: -200 °C ... +100 °C (900 °C - with neck tube), class 1 meas. range: -200 °C ... +100 °C (600 °C - with neck tube), DIN cl. B
Probe length: type K or N, mineral insulated thermocouple:
meas. range: -200 °C ... +100 °C (900 °C - with neck tube), class 1
Transmitter
up to 100 mm (without upcharge)
upcharge per further starting 100 mm Probe length:
Neck tube length: up to 100 mm (without upcharge)
without (without upcharge) upcharge per further starting 100 mm
upcharge per starting 100 mm Neck tube length:
Probe diameter: without (without upcharge)
3 mm, 4 mm, 5 mm, 6 mm or 8 mm (without upcharge) upcharge per starting 100 mm
Thread: Probe diameter:
G1/2“ (standard) (without upcharge) 3 mm (the sensor inset is not exchangeable) (without upcharge)
G1/8“, G1/4“, G3/8“, G3/4“, M8x1, M10x1 4 mm, 5 mm, 6 mm or 8 mm (the sensor inset exchangeable)
Cable: Thread:
G1/2“ (standard) or without thread
Temperature probe
silicone cable, standard lenght 1 m
upcharge per further starting m cable G1/8“, G1/4“, G3/8“, G3/4“, M8x1, M10x1
Ambient temperature: Ambient temperature:
-20 ... +60 °C (protection type „e“) or -20 ... +80 °C (protection type „i“) -20 ... +60 °C (protection type „e“) or -20 ... +80 °C (protection type „i“)
Type of protection: Type of protection:
„i“: intrinsic safety (without upcharge) „i“: intrinsic safety (without upcharge)
„e“: increased safety „e“: increased safety
Potentially explosive atmospheres: Potentially explosive atmospheres:
suitable for zone 0/1, zone 1, zone 2, zone 20/21, 21, zone 22 suitable for zone 0, zone 1, zone 2, zone 20, zone 21, zone 22
To determine exact order name ask for our type list. Download via homepage possible Transmitter GITT 01-Ex
(Products -->Ex-Protection-->Temperature probes). (please refer to page 119), output signal 4-20 mA, measuring range on customers
demands, protection type „i“ intrinsic safety.
Clamping ring screw connection:
available at M8x1, M10x1, G1/4“ and G1/2“ for diameter 3 mm, 6 mm or 8 mm.
Please refer to page 158
Simulator
To determine exact order name ask for our type list. Download via homepage possible
(Products -->Ex-Protection-->Temperature probes).
Alarm / Protection, Level
155
further information on www.greisinger.de
WATER PROOF, HERMETICALLY SEALED TEMPERATURE PROBES
Handheld instrument
HIGHLIGHTS:
TF101P
Logger / EASYBus
SIVE
FOR USE IN AGGRES
TIGHT PLACES
ENVIRONMENTS AND
HIGHLY RESILIENT TO
S
CHEMICALS AND OIL
Transmitter
TF101K
Temperature probe
TF101P-2m TF101K-2m
Product-ID: 601689 Product-ID: 601798
Pt100, cable length 2 m NiCr-Ni, cable length 2 m
TF101P-3m TF101K-3m
Product-ID: 601691 Product-ID: 601797
Pt100, cable length 3 m NiCr-Ni, cable length 3 m
Specifications: Specifications:
Simulator
V4A also available with thermocouples type J, T and E
robust design type with robust V4A protective tube Ø 3 mm, FL = 50 mm
not possible at type K, please specify when ordering!
156
further information on www.greisinger.de
Temperature probe
SELF-ADHESIVE TEMPERATURE PROBES
WITH MOULDED SILICONE DESIGN FOR SURFACE MEASUREMENT ON CURVED AND FLAT SURFACES
Handheld instrument
12
HIGHLIGHTS:
m
m
m
m
35 • sensor have adhesive back for easy mounting
15
• ultra-slim silicone rubber for maximum flexibility
m
m
m
50 m • resistant to a variety of chemicals and oils
• 2 designs for flat (GOF 112) or curved (GOF 115) surfaces available
Display / Controller
GOF 112
GOF 115
Logger / EASYBus
Product-ID: 604696 Design type NiCr-Ni (type K):
NiCr-Ni, adhesive back 35 x 12 mm, cable length 2 m, green The integral thermocouple sensor is bonded onto the inner surface of the self adhesive
aluminum foil strip, which is provided for fast response time
GOF 115 Pt • stranded NiCr-Ni-thermocouple wire (0.14 mm²)
Product-ID: 603203 • temperature range: -50 ... +200 °C
Pt100, adhesive back 15 x 50 mm, cable length 2 m, white • also available with thermocouples type J, T and E
GOF 115 K
Product-ID: 603458
NiCr-Ni, adhesive back 15 x 50 mm, cable length 2 m, green
„CEMENT-ON“ THERMOCOUPLES
Transmitter
style 1 style 2 HIGHLIGHTS:
9,4 40,6
10
• ultra fast response time:
20,3 12,7 17,8 (style 1:t63 = approx. 20 ms, style 2: approx. 5 ms, style 3: approx. 300 ms)
Temperature probe
GOF 120 - K1
Product-ID: 604184
NiCr-Ni, cable length 90 cm, max. 260 °C (short-time: 370 °C)
GOF 120 - K2
Product-ID: 604334
NiCr-Ni, cable length 15 cm, max. 540 °C (short-time: 650 °C)
GOF 120 - K3
Product-ID: 603249
NiCr-Ni, cable length 90 cm, max. 260 °C (short-time: 370 °C)
Simulator
General:
The series GOF 120 are a model line of Cement-On, fast response thermocouples for fast
surface temperature measurement. The model line have 3 different styles.
(Please order the high temperature cement separately)
The design styles 1 and 2 are made from 0.01 mm thermocouple alloy foil by a special
style 3 process where the butt welded thermocouple junction is 0.25 mm in thickness. The thermo-
couples are fabricated from class 1!
9,7
These styles are fl at, extremely low inertia construction and are ideal means of measuring
the temperature of both fl at and courved metals, plastic and ceramic surfaces where very
Alarm / Protection, Level
20,3 fast response is desired.
The design style 3 is an economy version constructed from 0.25 mm diameter bead
welded standard limit of error thermocouple wire. It should be used where extremely fast
response time is not essential.
157
further information on www.greisinger.de
ACCESSORIES
Handheld instrument
CLAMPING RING SCREW CONNECTION GKV... STAINLESS STEEL FLAT-PIN CONNECTIONS, FREE FROM THERMAL E.M.F.
(for all probes without thread) (for type K, N, S)
NST1200 "K"
Product-ID: 602566
Type: Outside thread Clamp. ring-Ø Clamping ring
(sensor tube-Ø) NKU1200 "K"
Product-ID: 602737
GKV1
tefl on
Product-ID: 602888
1.5 mm NKU1200 O "K"
GKV2 Product-ID: 602738
stainless steel
Product-ID: 602889 (max. 120 °C)
M8 x 1
GKV3
Logger / EASYBus
Product-ID: 602890
3.0 mm
tefl on
NST1300 "N"
GKV4 Product-ID: 605762
stainless steel
Product-ID: 602891
GKV5 NST1700 "S"
tefl on Product-ID: 603890
Product-ID: 602892
1.5 mm
GKV6
Product-ID: 602893
stainless steel NKU1700 "S"
Product-ID: 603535
GKV7
tefl on
Product-ID: 602894
G1/4" 3.0 mm For higher temperatures use ceramic plug and coupling.
GKV8
stainless steel
Product-ID: 602895
GKV11
tefl on
Product-ID: 602898
IMMERSION SLEEVE OF STAINLESS STEEL
Transmitter
6.0 mm
GKV12
stainless steel
Product-ID: 602899
Immersion sleeve for probes without thread
GKV9
tefl on G½“ or as required
Product-ID: 602896
6.0 mm
GKV10 6 or as required
stainless steel
Product-ID: 602897
GKV13
G1/2" tefl on
Product-ID: 602900 or as required
GKV14
8.0 mm
stainless steel
EST01
Product-ID: 602901 Product-ID: 602868
Temperature probe
GKV15 Basic price for 100 mm
14.0 mm tefl on
Product-ID: 602902
General:
GKV16
M10x1 6.0 mm stainless steel Thread: G1/2 (external thread)
Product-ID: 602903
Outer diameter immersion sleeve: Ø 6 mm
(for probes with outer diameter Ø 5 mm)
length: L = 100 mm (suitable for e.g. GTF101 with FL = 105 mm, Ø 5 mm)
Special lengths, diameters or threads upon request
G½“ internal thread
Simulator
or as required
EST02
Product-ID: 603362
for 85 mm
General:
Thread: G1/2 (internal/external)
Outer diameter immersion sleeve: Ø 8 mm
Alarm / Protection, Level
(for probes with outer diameter Ø 6 mm)
L = 85 mm (suitable for e.g. GTF103 with FL = 100 mm, Ø 6 mm)
L = 100 mm (suitable for e.g. GTF103 with FL = 115 mm, Ø 6 mm)
Special lengths, diameters or threads upon request
GWL10G
Product-ID: 603267
heat-conductive paste 10 g, in plastic gun, for faster heat exchange
158
further information on www.greisinger.de
Temperature probe
ACCESSORIES
Handheld instrument
CABLES AND LINES SENSOR ELEMENTS (PT100/1000, NTC, PTC)
Silicone cable (-50 ... +200 °C) with teflon screened wires
S2P
silicone cable, 2-pole (2 x 0.25 mm²), highly fl exible,
external diameter approx. 3.8 mm
S4P
silicone cable, 4-pole, 4 x 0.14 mm² cross section (insulation 2 x blue, 2 x white)
(can also used as 3-wire), external diameter approx. 4 mm,
price per meter Pt100/1
Display / Controller
Product-ID: 602989
Glass silk insulated cable (-50 ... +400 °C) with stainless steel braiding Ceramic lamina, 2 x 2.3 x 0.6 mm, -70 ... +500 °C, tolerance: B
G4P Pt100/2
glass silk insulated cable, 4-pole (4 x 0.22 mm²), Product-ID: 602990
external diameter approx. 4 mm, price per meter Ceramic lamina, 2.5 x 2.0 x 1.3 mm, -50 ... +500 °C, tolerance: 1/3 DIN
Teflon insulated cable (-200 ... +250 °C) with individual teflon insulated wires Pt100/3
Product-ID: 602991
T2P Ceramic lamina, 2 x 5 x 0.9 mm, -196 ... +500 °C, tolerance: B
tefl on insulated cable, 2-pole (2 x 0.14 mm²), with additional cable screen,
external diameter approx. 2.3 mm, price per meter Pt100/4
Product-ID: 602993
Logger / EASYBus
T4P Wound design, Ø 2 x 20 mm, -200 ... +600 °C, tolerance: B
tefl on insulated cable, 4-pole (4 x 0.14 mm²), with additional cable screen
external diameter approx. 4 mm, price per meter Pt100/5
Product-ID: 602994
PVC-lines (-20 ... +70 °C) TO92-housing, -50 ... +150 °C, tolerance: B
P2P Pt100/6
PVC cable, 2-pole (2 x 0.14 mm²), external diameter approx. 3.5 mm, Product-ID: 602995
price per meter Ceramic lamina, 1 x 3 x 0.6 mm, -50 ... +500 °C, tolerance: B
P4P Pt1000/1
PVC cable, 4-pole (4 x 0.14 mm²), external diameter approx. 3.9 mm, Product-ID: 606368
price per meter Ceramic lamina, 2.1 x 4 x 0.9 mm, -50 ... +400 °C, tolerance: B
Transmitter
Extension cable for NiCr-Ni (Type K) Pt1000/2
Product-ID: 602997
VKA 1m TO92-housing, -50 ... +150 °C, tolerance: B
Product-ID: 602909
1 m Silicon-Compensation lines with DIN plug and DIN coupler Pt1000/3
Upcharge per meter Product-ID: 602998
Ceramic lamina, 1 x 3 x 0.6 mm, -50 ... +500 °C, tolerance: B
Compensation lines for NiCr-Ni (type K), 2-wire
KTY 81-210
AGL1 Product-ID: 607894
Silicone cable (2 x 0.22 mm²) (max. 200 °C), external diameter approx. 3.8 mm, Replacement for KTY 11-6, -20 ... +110 °C
Temperature probe
price per meter
KTY 81-121
AGL3 Product-ID: 607895
Thermo wire (can also be used as thermo couple) glass silk (2 x 0.5 mm²) 1 kOhm (25 °C), TO92-housing, -50 ... +150 °C
(max. 400 °C), external diameter approx. 4 mm, price per meter
For larger quantities special prizes - upon request
AGL4
Tefl on screened twisted thermo wire without joint outer sheath, wire Ø 0.2 mm
(max. 250 °C), external diameter approx. 1.4 mm, price per meter
AGL5
Thermo wire, with glass silk braiding, wire-Ø 0.2 mm (max. 400 °C), external
diameter 0.8 x 1.2 mm, price per meter
AGL6
Simulator
Tefl on cable, screened - can also be used as thermo couple (2 x 0.22 mm²)
(max. 250 °C), with additional cable screen, external diameter approx. 4 mm,
price per meter
AGL S2
Silicone cable (max. 200 °C), external diameter approx. 3.9 mm
price per meter
Alarm / Protection, Level
AGL N2
Silicone cable (max. 200 °C), external diameter approx. 3.9 mm
price per meter
159
further information on www.greisinger.de
SIMULATOR
Handheld instrument
Display / Controller
Logger / EASYBus
Transmitter
160
further information on www.greisinger.de
Simulator
SIMULATOR
Handheld instrument
NEW ! HIGHLIGHTS:
Display / Controller
• Graphic LCD
• Compact dimensions
• Battery-operated
Logger / EASYBus
FIRST AVAILABLE IN QUARTER 2 OF 2016
Transmitter
simulation of sensors like Pt100 and strain gauge sensors.
Thermocouples, type K (others optional)
Application: Measurement ranges: -100 ... +1000 °C (in 50 °C increments)
It can be used to compare and check displays and measuring transducers or transformers Accuracy: ± 1 %
or complete measuring distances. Voltages and currents can also be measured with the
device. Pt100
Measurement ranges: -100 ... +850 °C (in 50 °C increments)
Specifications: Accuracy: ± 1 %
General:
Accuracy: see under Sensors Measurement function:
Connections: 7-pin Binder socket for signal input and output Voltage source:
Temperature probe
Mini USB for voltage supply / charge function
Measurement range: ± 30 V
Display: Graphic LCD, monochrome, adjustable background light
Accuracy: ± 0.1 %
(180 x 128 pixels)
Current
Operation: Keypad
Measurement range: ± 30 mA
Supported languages: German / English
Accuracy: ± 0.1 %
Dimensions: 86 x 160 x 37 mm (W x H x D)
Scope of supply: GHM SensorSimulator, battery, charger, manual
Weight: 250 g (including battery)
Supply voltage: 5 V DC (Mini-USB)
Battery: NiMH battery
Ambient temperature: 0 ... +50 °C
Simulation function:
Voltage source:
Simulator
161
further information on www.greisinger.de
ALARM / PROTECTION, LEVEL
Handheld instrument
Display / Controller
ALSCHU 485 OE / 3P
ALSCHU 485 OE
ALSCHU 300 FG
ALSCHU 300 SP
GEWAS 191 AN
ALSCHU 480 P
GEWAS 191 N
GEWAS 181 A
GEWAS 183 A
ALSCHU 485
ALSCHU 480
GEWAS 200
Application: - ¾“, - 1“
Universal Application ● ● ●
Level controler ● ● ●
Water leak detector ● ● ● ● ●
Transmitter
Electrodes incl. ● ● ● ●
Alarm buzzer ● ● ● ● ● ●
Switching output ● ● ● ● ● ● ●
Water supply is switched of ● ● ●
Device information:
Temperature probe
Catalogue page 163 164 164 165 166 166 167 167
GEWAS 300 FG
GEWAS 300 SP
RWI-016 PPK
RWI-016 PVK
RW-015 HKL
GNS-SCV-W
GMNV-1C
GSS-F25
GNS-KIT
GNS-C1
GNS-C2
Application:
Simulator
Universal Application ●
Level controler ●
Water leak detector ●
Electrodes incl. ● ● ● ● ● ● ●
Alarm / Protection, Level
Alarm buzzer ● ●
Switching output ● / -
Water supply is switched of ● ● ● ● ● ● ● ●
Device information:
Catalogue page 168 168 169 170 170 170 169 169
162
further information on www.greisinger.de
Alarm / Protection, Level
3-PIN. PROBE FOR LEVEL
ELECTRODE CONTROLLER WITH TWO SIGNAL INPUTS CONTROL (CONDUCTIVE)
Handheld instrument
2 DIFFERENT
MOUNTING FORMS
Display / Controller
CAN BE
SHORTENED
FIELD FRAME
SNAP-ON HOUSING
Logger / EASYBus
ALSCHU 300 FG Working -20 … +60 °C GNS-3P-SLV
Product-ID: 600476 temperature: Product-ID: 604786
Electrode controller in fi eld frame for wall mounting, Storage temperature: -40 … +80 °C 3 electrodes with Poliolefi n coating
device without sensor Condensation: not allowed • cooling water
• all conductive liquids
ALSCHU 300 SP Functions / displays:
Product-ID: 600479 Red / green LED: display for switching state of relay,
switching state of sensors, status
GNS-3P-SLK
Electrode controller in snap-on housing for DIN rail Product-ID: 604016
(supply) of device
mounting, device without sensor 3 electrodes with Kynar coating
Transmitter
Housing: • food and beverage industry
Application:
ALSCHU 300 SP: snap-on housing for DIN rail • chemical industry
Automatic control of drainage pumps and wastewater mounting
lifting plants, overfl ow and low liquid level control, auto-
matic fi lling and draining of tanks, level control of liquid
Dimension: 22,5 x 75 x 110 mm (W x H x D) GNS-3P-SLE
reservoirs, aquariums, storage tanks, etc. ALSCHU 300 FG: fi eld frame Product-ID: 603172
The ALSCHU 300 .. is especially suitable for detection 3 electrodes with PTFE coating
Dimension: 100 x 100 x 60 mm (W x H x D)
of conducting media (water, etc.). It is less applicable without PG cable glands
• aggressive conductive liquids
for badly or non conducting media (oils or fatty liquids), General:
Scope of supply: device, manual
conducting foaming liquids or media causing electrically
isolating deposits on the electrodes. • Coated electrodes
Accessories and spare parts: • Rugged construction, sealed
Temperature probe
Measuring method: GNS-3P • Alarm or level regulation or dosage of liquids
Product-ID: 603170 • Combined with control electronics (ALSCHU 300,
The measuring method for level detection is based on the ALSCHU 485 OE / 3P) an accurate liquids level control
3-pole level probe
conductive principle, i.e. the electrical conductivity of the system
(p.r.t. page 164)
media is monitored. If the switching amplifi er detects a
value below the set conductivity the state “media detected” GNS-3P-SLV
Specifications:
is output, otherwise “no media”. Depending on number Product-ID: 604786
and design of the connected level sensors the device can GNS-3P-SLK Number of 3 pieces
be used for level detection (min-/max-detection) or as 2-point Product-ID: 604016 electrodes:
controller. GNS-3P-SLE Length of electrodes: 500 mm,
Product-ID: 603172 other lengths upon request,
Specifications: 3-pole level probe with coating probes can be cutted to needed
Power supply: 18 V … 250 V AC/DC GSS-1 length
wide-range power supply Product-ID: 606016 Electrical EN 175301-803/A plug
Power consumption: < 2 VA level sensor, 2 m cable (fl oating switch) for connection:
electrically non-conducting media
Process G 1“, Polypropylen
Simulator
2 signal inputs:
GNS-1 connection:
Triggering level: < 80 kΩ Product-ID: 602531
Pressure max.: 6 bar
Response time: 2 s level sensor, 2-pole (stainless steel electrode)
Temperature max.: +100 °C
1 Relay output:
Protection class: IP65
Contact: change-over contact, potential-
free Dimensions: SW: 40 mm
A: 68 mm
Switching voltage: ≤ 250 V AC B: 20 mm
Switching current: ≤ 5 A (ohmic load) L: 500 mm
Protection class: IP20 (ALSCHU 300 SP) and
Alarm / Protection, Level
IP65 (ALSCHU 300 FG)
Electric connection:
ALSCHU 300 SP: connection via screw-type terminal
ALSCHU 300 FG: connection via 3 PG cable glands
and screw terminals
Scope of supply: Device, manual
suitable for:
Alschu 300 FG, Gewas 300 SP, ALSCHU 485 OE / 3P
163
further information on www.greisinger.de
3-PIN. PROBE FOR LEVEL
PLUG-IN LEVEL CONTROLLER CONTROL (CONDUCTIVE)
Handheld instrument
HIGHLIGHTS:
• no installation costs
• trouble-free operation as
no moveable float switches are used
CAN BE
SHORTENED
Ø 18 MM
ALL
NO MOVING PARTS AT upper level
Logger / EASYBus
ALSCHU 300 SP
Product-ID: 600479
Electrode controller in 2 different mounting forms: fi eld
frame or snap-on housing (see previous page)
164
further information on www.greisinger.de
Alarm / Protection, Level
LEAK-WATER DETECTOR
Handheld instrument
NO MORE
E
AG
AT
W
ER DAM
Display / Controller
Figure GEWAS 181 A
Logger / EASYBus
GEWAS 181 A Specifications:
Product-ID: 601734 Power supply: 220 / 240 V 50 / 60 Hz (control unit)
leak-water detector with ½“ brass solenoid valve with ¾“ connections for hand Power consumption: approx. 2,5 Watt (control unit, approx. 6 W incl. solenoid valve)
installation, water sensor, alarm buzzer and switch-off of connected units
Control output: via power socket of safety plug adapter
16 A, 230 V~
max. switching current: max. 16 A (ohmic load)
GEWAS 183 A Water sensor: Highly sensitive, plug-in water sensor, 2 m of cable, alarm
Product-ID: 602999 triggered as of ½ mm water fi lm. Simultaneous plug in of
leak water detector without solenoid valve, with water sensor, alarm buzzer and several water sensors via socket-outlet adaptor GAZ1.
switchoff of connected devices 16 A, 230 V~ Plug-in extension cable (2 m, 5 m or 10 m long) available.
Solenoid valve: Hence, valve operable in permanent mode; due to energy-
GEWAS 181 A - ½“ saving circuit valve will not run hot even without cooling agent.
Product-ID: 601736 Valve permanently fi xed to control device (approx. 1 m of
Transmitter
leak water detector with ½“ brass solenoid valve (fl ow quantity: approx. 20 l/ connecting cable). Valve body can be removed from coil after
min, installation length approx. 55 mm) for installation in the line, water sensor, loosening of one nut.
alarm buzzer and switch-off of connected devices 16 A, 230 V~. max. working 10 bar, servo-controlled
pressure: (pressure difference inlet/outlet > 0.5 bar)
GEWAS 181 A - ¾“ Working voltage: 200 V DC or 100 V DC in energy saving mode
Product-ID: 601738 Working temperature: 0 ... 50 °C
leak water detector with ¾“ brass solenoid valve (fl ow quantity: approx.
Dimensions: control device: 110 x 65 x 45 mm (L x W x H),
91.5 l/min, installation length approx. 80 mm) for installation in the line, water with suspension hook
sensor, alarm buzzer and switch-off of connected devices 16 A, 230 V~
Scope of supply: Device, solenoid valve (not GEWAS 183 A), water sensor,
GEWAS 181 A - 1“ manual
Temperature probe
Product-ID: 601740 Accessories and spare parts:
leak water detector with 1“ brass solenoid valve (fl ow quantity: approx. 141.5 l/
GMV-½“ L
min, installation length approx. 95 mm) for installation in the line, water sensor, Product-ID: 601645
alarm buzzer and switch-off of connected devices 16 A, 230 V~ spare solenoid valve ½“ for direct cable connection, approx. 1 m cable, loose ends
Application: GMV-½“ H
Any devices or machines with water connection. For direct mounting of solenoid valve in Product-ID: 601646
pipelines. spare solenoid valve ¾“ manual mounting, approx. 1 m cable, loose ends
GMV-¾“
Mode of action: Product-ID: 601648
If a water fi lm of more than 0.5 mm occurs at the water sensor the control unit automati- spare solenoid valve ¾“ for direct cable connection, approx. 1 m cable, loose ends
cally gives an acoustic alarm and switches the solenoid valve and the device connected to GMV-1“
the control unit off. Product-ID: 601655
Solenoid valve: spare solenoid valve 1“ for direct cable connection, approx. 1 m cable, loose ends
Brass solenoid valve, energy-saving circuitry for hand installation (½” with ¾” glanding
GMV-½“ EZL
Simulator
- suitable for any ½” tap or ½” tube) or with ½”, ¾” or 1” internal thread on both sides
Product-ID: 601657
for line installation. De-energised when closed, for pressure loads from 0.5 ... 10 bar.
add. solenoid valve 1/2“ for direct cable connection, with power saving connector, approx.
Servo-controlled, i.e. free water outlet has to be provided resp. infeed pressure has to
2 W, for direct connection to 230 VAC, suitable for GEWAS 183A or mains operation
exceed outfeed pressure by 0.5 bar (solenoid not suitable for closed circuits such as
heating systems). GMV-½“ EZH
Product-ID: 601660
like before, but ¾“ valve for manual mounting
GMV-¾“ EZ
Product-ID: 601662
like before, but ¾“ valve for direct cable connection
Alarm / Protection, Level
GMV-1“ EZ
Product-ID: 601650
like before, but 1“ valve for direct cable connection
Plug-in water sensor, socket outlet adapter, extension cable p.r.t. GEWAS 191
165
further information on www.greisinger.de
PROTECTION DEVICE FOR UNIVERSAL APPLICATION PROTECTION DEVICE FOR UNIVERSAL APPLICATION
Handheld instrument
TPUT
WITH SWITCHING OU
FO R AN Y PURPOSE
PANEL MOUNTED
DEVICE
Display / Controller
WITH SWITCHING
OUTPUT
-IN
AVAILABLE AS PLUG
Logger / EASYBus
The ALSCHU 480(P) is a versatile alarm and protection device. Its universal input (3.5 mm
jack bush) allows a lot of different external sensors to be connected. That includes sen-
Specifications:
sors with a switching threshold <100 kOhm like water sensors, fl oat switches, level swit-
ches, magnetic contacts, safety shut-off mat etc. In case of an alarm the internal buzzer Power supply: 220/240 V 50/60 Hz
sounds and a connected device (i.e. pump, machine) is switched on or off via the Schuko Power consumption: approx. 3 VA
adaptor plug (ALSCHU 480). The desired switching function can be set via selector switch
Sensor input: 2-pole screw terminal
I / II. ALSCHU 480P switches on/off external devices via a potential-free 2-pole switching
output. The Schuko socket of ALSCHU 480P is always current-carrying. Switching threshold: input resistance < 100 kOhm (eg. NPN no active, relay, reed
contact, etc.)
Specifications: Switching output: potential-free change-over contact
Power supply: 220/240 V 50/60 Hz Switching power: 250 V AC, 10 A (ohmic load), max. 2400 VA
Power consumption: approx. 1 VA 150 V DC, 2 A (ohmic load), max. 240 W
Temperature probe
480 P: 120 VDC, 2 A (ohmic load), max. 240 W
Controlling device: LED for operation display, device-on/off, selector switch I / II Accessories and spare parts:
for switching function
GWF-1
Working conditions: -20 ... +50 °C; 0 ... 80 % RH Product-ID: 601712
Dimensions: 112 x 71 x 48 (L x W x H) water sensor without plug, 2 m
Scope of supply: Device, manual GSS-1
Product-ID: 606016
Accessories and spare parts: level probe (plug-in fl oat switch), 2 m cable for electrically non-conductive media (normally
open/normally closed function can be selected by customer)
GWF-1S
Alarm / Protection, Level
166
further information on www.greisinger.de
Alarm / Protection, Level
Handheld instrument
FOR ULTRAPURE
WATER
Display / Controller
GWF-2
Product-ID: 601778
Textile-tape water sensor, 2 m, without plug
General:
Logger / EASYBus
The GWF-2 detects smallest amounts of water due to the
specially treated textile tape on its reverse side.
Transmitter
Working conditions: 0 ... +50 °C, 0 ... 90 % RH Scope of supply: Device
washing machine, dish washer, surgeries (e.g. dentists’ (non-condensing)
surgeries, water-cooled devices etc.), hospitals, industry, suitable for:
research, laboratories, any other devices and machines Dimensions: control unit: 126 x 79 x 54 mm
(L x W x H) Gewas 200, Gewas 300 FG, Gewas 300 SG
with water connection (e.g. hot drinks dispensers, cooling
devices etc.) solenoid valve: 82 x 102 x 41 mm
Scope of supply: Water leak detector with solenoid
General: valve, controller, water probe,
If a water fi lm of more than 0.5 mm occurs at the water signal buzzer, manual
sensor the control unit automatically gives an acoustic
alarm and switches the solenoid valve off. The design Accessories and spare parts:
type GEWAS 191 AN turns off additionally the device GMV191
Temperature probe
connected to the control unit, too. Product-ID: 601664
spare solenoid
Specifications: GWF-1S
Power supply: 220/240 V 50/60 Hz (control unit) Product-ID: 601706
Power consumption: approx. 3 VA plug-in water sensor, 2 m
Control output: via power socket at device GWF-1S / 5m
housing (only for GEWAS 191 Product-ID: 601708
AN) the socket of GEWAS 191 N plug-in water sensor, 5 m
always provides mains voltage GWF-1S / 10m
max. switching max. 16 A (ohmic load) Product-ID: 601710
current: plug-in water sensor, 10 m
Water sensor: highly sensitive plug-in water pro- GAZ-1
be, 2 m cable. Alarm triggered as Product-ID: 602748
of ½ mm water fi lm. Several water branch adapter (required for each additional water sensor)
Simulator
probes can be plugged-in and used VEKA 2
simultaneously by means of Product-ID: 601726
socket outlet adaptor GAZ 1. 2 m, extension cable 2 m
5 m or 10 m plug-in extension VEKA 5
cable available.
Solenoid valve: glass fi ber reinforced polyamide
Product-ID: 601728
extension cable 5 m
GWF-1
(as customary for washing machi- Product-ID: 601712
VEKA 10
nes). Safety-low voltage 12 V DC. Water sensor, 2 m, without plug
Product-ID: 601731
Connections: Screw connection extension cable 10 m Variants:
¾“ for direct fastening to water tap
and the standard dish washer / GWF-1/5m
Alarm / Protection, Level
167
further information on www.greisinger.de
DEVICE FOR MONITORING
WATER MONITOR WITH ONE SIGNAL INPUT AND ONE RELAY OUTPUT THE LEVEL (CAPACITIVE)
Handheld instrument
2 DIFFERENT
MOUNTING FORMS
Display / Controller
GNS-SCV-W
Product-ID: 603168
Probe for application in water and all conductive
liquids
Probe for application in oil and all no-conductive
liquids
GEWAS 300 FG Electric connection: General:
Product-ID: 600472 GEWAS 300 SP: connection via screw-type terminal The GNS-SCV capacitive probes are the best way to
Wasserwächter im Feldgehäuse für Wandmontage GEWAS 300 FG: connection via 3 PG cable glands monitor the level condition of liquids as water, oil gasoline
Gerät ohne Sensor and screw terminals and solid products as powder and garanular.
• Sealed
GEWAS 300 SP Working
temperature:
-20 … +60 °C • No moving parts
Product-ID: 600474 • very reliable
Wasserwächter im Schnappgehäuse für Storage -40 … +80 °C
temperature: Application:
Hutschienenmontage, Gerät ohne Sensor
Condensation: not allowed • Water
Application: • Oil
Functions / displays:
• Gasoline
Transmitter
GEWAS 300 FG:
isolating deposits on the electrodes. Electrode coating: PTFE
push-button at front side
Description: Housing: Electrode length: 50 mm
The measuring method for level detection is based on the GEWAS 300 SP: snap-on housing for DIN rail Switch point:
conductive principle, i.e. the electrical conductivity of the mounting 22.5 x 75 x 110 mm 40 mm ± 2 mm vertical mounting
media is monitored. If the switching amplifi er detects a (W x H x D) on the axis of SCV horizontal mounting
value below the set conductivity the state “media detected” GEWAS 300 FG: fi eld frame 100 x 100 x 60 mm
is output, otherwise “no media”. Pressure max.: 25 bar
(W x H x D) without PG cable
glands Temperature max.: -30 ... +125 °C
Specifications:
Scope of supply: Device, manual Dimensions [mm]:
Power supply: 18 V … 250 V AC/DC,
wide-range power supply Accessories and spare parts: SW A B L0 L1
Power < 2 VA 24 74 10 50 40 ± 2
GWF-1
consumption: Product-ID: 601712
Simulator
168
further information on www.greisinger.de
Alarm / Protection, Level
LEVEL MODULE CONDUCTIVE LIMIT DETECTOR CONDUCTIVE SINGLE CONTACT LEVEL SWITCH
Handheld instrument
Display / Controller
Figure with option rail adapter
Logger / EASYBus
GMNV-1C GNS 20E - 200 GNS-KIT
Product-ID: 605742 Limit detector conductive 200 mm Product-ID: 603164
Level module conductivel level switch, without rod tube
General:
GNS 20E - 500 (state rod tube length when ordering)
Limit detector conductive 500 mm
This module is used for evaluation of single levels with General:
conductive level sensors. The module can be directly General: The user can add by himself the level switch in the desi-
attached to the connection head of the level probes or Conductive measuring principle, suitable for use with red length the rod tube between the process connection
snap on a hat rail with the optionally available rail adapter. aqueous, conducting media. Less suited for low- or non- and the fl oat contact unit. The fl oat contact unit is under
conducting media and for foaming, adhesive or coating water protected.
The GMNV-1C uses 3-wire connection technology and it media. • Sealed under water protected contact
converts the conducting connection between probe rod • Rod tube in 500 mm / 1000 mm / 1500 mm available
Transmitter
and ground to a DC switching signal. This signal can be Application: state when ordering
directly interpreted and processed e.g. by a SPS. • full / empty detector in tanks • IP65 protection class
• overfi ll protection
• no additional level device needed at control cabinet • protection against dry running Specifications:
• low installation costs Float-contact unit: Nickel plated brass
• little amount of cabling Specifications:
• high immunity Density: > 0.35 g/cm3
Sensitivity: 0.1 / 1 / 10 / 100 kOhm Pressure max.: 20 bar
Specifications: (selectable by jumpers)
Temperature max.: 105 °C
Electrode connection: 2-wire Auxiliary voltage: 15 … 36 V DC
Connection: 1/8”
Sensitivity: 0.1 / 1 / 10 / 100 kOhm Output: active output
Reed-contact: SPDT: 230 V, 60 VA, 1.0 A
(selectable by jumpers)
Temperature probe
Output voltage: auxiliary voltage -10 %
Process connection: Thread G1”, Brass
Auxiliary voltage: 15 … 36 V DC Max. output 50 mA (short-circuit proof)
current: Electrical connecton: Plug EN 175301-803/A
Output: active output
Switching function: full / empty detector Protection Class: IP65
Output voltage: auxiliary voltage -10 %
(selectable by jumpers) Seal: NBR, oil resistant
Max. output 50 mA (short-circuit proof)
current: Delay: 0.5 s Rod-tube: Ø 8 mm, brass
Switching function: full / empty detector Working conditions: -10 … +60 °C; 0 … 95 % RH
(non-condensing) Accessories and spare parts:
(selectable by jumpers)
Storage temperature: -20 … +60 °C GNS ROHR-0500
Delay: 0.5 s
Product-ID: 603165
Working conditions: -10 … +60 °C; 0 … 95 % RH Pressure max.: 10 bar Rod-tube for GNS KIT, 500 mm
(non-condensing) Electric connection: via screw-type terminals GNS ROHR-1000
Storage temperature: -20 … +60 °C max. wire diameter: 2.5 mm² Product-ID: 603166
Electric connection: via screw-type terminals Cable feedthrough: for cables with diameter 5 - 14 mm Rod-tube for GNS KIT, 1000 mm
Simulator
(till thread end)
rail adapter …-500: approx. 530 mm
Product-ID: 603659 (till thread end)
Electrodes can be shortened.
Scope of supply: Device, manual
169
further information on www.greisinger.de
LEVEL SWITCH
STANDARD UNIT LEVEL SWITCH FLOAT SWITCH
Handheld instrument
RWI-016PPK
Display / Controller
RW-015HKL
GNS-C1 RWI-016PPK
Product-ID: 606051 Product-ID: 602912
Level Switch (with 1 microswitch) Float switch (polypropylene)
GNS-C2 RWI-016PVK
GSS-F25 Product-ID: 606210 Product-ID: 602913
Logger / EASYBus
Level Switch (with 2 microswitches) Float switch (PVDF)
Product-ID: 603245
Level Switch Standard Unit General: RW-015HKL
General: These level switches offer the most reliable solution for Product-ID: 606211
liquid level control were side mounting system is required. Float switch (stainless steel)
The level switches offer to the user a simple and reliable • Switch head magnetically actuated
solution in the liquid level control application. These stan- • 1 or 2 microswitches General:
dard units are available with cable length of 3.0 m. • Adjustable stem length
The working principle is based on the movement of the ma- Mechanical level controller for liquids. A magnet-equipped
• Brass or AISI-316 construction fl oat triggers a pre-fi xed reed switch.
gnetic fl oat which drives the reed switch inside the level-stem. • good repeatabilty
The cable and switch are epoxy sealed inside the stem and • wall mounting
• very reliable • reliable and with good repeatabilty
the sealing process is produced by a temperature controlled
heating system. A rugged and free of maintenance product. • stainless steel design for high temperatures
Specifications:
• Constructions up to 180 °C working temperature on
request Processconnection: G1” Application:
Transmitter
Assembly externally:
Alarm / Protection, Level
Hole diameter Ø 23 mm
Stem position:
1 Microswitch 2 Microswitch
ON OFF ON OFF
Long -46 mm -63 mm -32 mm -49 mm
Medium -48 mm -61 mm -34 mm -47 mm
Short -50 mm -60 mm -36 mm -46 mm
Switch point tolerance: ±5 mm
170
futher information on www.greisinger.de
General Information
Handheld instrument
Display / Controller
Logger / EASYBus
Quality
Made in Germany
Transmitter
Our commitment - Flexibility
Temperature probe
Your advantage and Innovation
Simulator
Competence
in Measurement
Alarm / Protection, Level
171
futher information on www.greisinger.de
Handheld instrument
Temperature
Humidity
Laboratory Measurement Pressure
(Handheld Instruments) Conductivity
pH / ORP
Sensors
Logger / EASYBus
Switching relays
Isolating converters
Industrial Electronics / Measurement transmitters
Control Technology Displays / Controller
Monitoring relays
Data logger /
EASYBus
Temperature
Flow
Transmitter
Level
Process Engineering
Pressure
Conductivity
pH
Flow
Level
Industrial Measurement Temperature
Temperature probe
Pressure
Humidity
Filtration
Customizing
Alarm / Protection, Level
172
futher information on www.greisinger.de
General Information
Handheld instrument
Information media of GHM Messtechnik
GHM-Kompetenzzentren Vertriebstöchter
(Entwicklung & Produktion)
GHM-Meettechniek BV
GHM Messtechnik GmbH Zeeltweg 30
Standort Honsberg 3755 KA Eemnes
Tenter Weg 2-8 Netherlands
explosive areas
Lebensmittel-, Getränke GHM Messtechnik GmbH
Anwendungen
und Pharmaindustrie
Standort Imtron
Carl-Benz-Straße 11
im Ex-Bereich
88696 Owingen
Germany
+49 - 7551 - 9290 - 0
Made in Germany +49 - 7551 - 9290 - 90
www.imtrongmbh.de
www.ghm-messtechnik.de info@imtrongmbh.de
Made in Germany
GHM Messtechnik GmbH www.ghm-messtechnik.de
Standort T&A
Miramstraße 87
34123 Kassel
Germany
+49 - 561 - 948710 - 50
+49 - 561 - 948710 - 51
www.tua-online.com
info@tua-online.com
Display / Controller
Unternehmen / Marken der GHM
Unternehmen / Marken der GHM
02/2015
Schloßstraße 6 +49 - 7354 - 937233 - 0
88453 Erolzheim www.ghm-messtechnik.de
Germany info@ghm-messtechnik.de
2
... professionelle M esstechnik „M ADE IN GERM ANY“
Logger / EASYBus
... professionelle Messtechnik „MADE IN GERMANY“
Kompetenzzentrum Vertriebstöchter
Special publication
www.martens-elektronik.de +45 - 646492 - 00
info@martens-elektronik.de +45 - 646492 - 01
Product compendium
www.ghm.dk
info@ghm.dk
GHM Messtechnik GmbH
Standort Honsberg
Tenter Weg 2-8 GHM-Meettechniek BV
42897 Remscheid Zeeltweg 30
Germany 3755 KA Eemnes
Produktkompendium
www.greisinger.de +420 - 251 - 612607
Transmitter
Unternehmen / Marken der GHM
Unternehmen / Marken der GHM
Made in Germany
www.ghm-messtechnik.de
Temperature probe
Unternehmen / Marken der GHM
Overview of brochures
D Laboratory measurement
Alarm / Protection, Level
E Industrial electronics
F Data logging
173
futher information on www.greisinger.de
Handheld instrument
GHM-Meettechniek BV
GHM Messtechnik GmbH Zeeltweg 30
Honsberg Office 3755 KA Eemnes
Tenter Weg 2-8 Netherlands
42897 Remscheid +31 - 35 - 53805 - 40
Germany +31 - 35 - 53805 - 41
+49 - 2191 - 9672 - 0 www.ghm-nl.com
Logger / EASYBus
www.greisinger.de
info@greisinger.de
info@tua-online.com
Alarm / Protection, Level
174
futher information on www.greisinger.de
General Information
INDEX
Handheld instrument
A-10 125 GFTB 200 … 27 GNS-SCV ... 168 GTMU - IF … 117 TS125 / TS225 141
A9648 95 GFTH 95 30 GNT 0520 127 GTMU-MP ... 114 TSA-PWR 144
AAA-AKKU 74 GFTH 200 … 30 GNTP-SG 116 GTO 130 OK 22 TV125L 140
AAG... 74 GGA... 56 GODOX-200 130 GTP-SG 116 TV500 / ST500 140
AF500 142 GGF 175 13 GOEL … 57 GTS 29
AGL … 159 GGF 200 22 GOF 112 … 157 GTT… 146 USB 100 106
ALARM 230 V 102 GGO … 56 GOF 115 … 157 GTT-15-150 22 USB 3100 N 74
ALSCHU 300 ... 163 GHE 91 35 GOF 120 ... 157 GTZ 300 21 USB 5100 74
ALSCHU 480 166 GHM SensorSimulator SIM-1 161 GOF 130 … 20 / 21 GVA 0430 70 USB 5200 74
ALSCHU 485 164 GHTU … 123 GOF 175 … 13 GWA 1214 63 USB-Adapter 74
APG … 102 GIA 010 N … 80 GOF 200 HO 20 GWA 1 ... 49 UZ9648 91
GIA 010 VOT ... / WKT... 100 GOF 400 … 20 GWF-1 167
BaleCheck ... 38 GIA 0420 N … 80 GOF 401 Mini 11 GWF-2 167 V9648 94
BW500 139 GIA 0420 VO … 100
Display / Controller
GOF 500 … 20 / 21 GWH... 112 VD 120 49
GIA 0420 WKT … 100 GOF 900 HO 20 GWL 10G 158 VEKA … 167
CaCl 47 GIA 20 EB … 82 GOG … 57 GWO 3600 52 VEKA 3105 74
CR 2032 106 GIA 2000 89 GOK 91 35 GWO 3600-...-MU 129 VISION 2008 131
CT500 137 GIA 2448 … 81 GOO … 56 GWO 5610 50 VKA 1m 146
CT500P 142 GIM 530 MS 24 GOX 20 51 GWOK 01 52 VT500 138
CVC-02/0201 144 GIM 3590 25 GOX 100 ... 58 GWZ-01 43 VTH 25MS-180 134
CVG500 139 GIR 2000 Pt … 88 GPAD 38 36 GZ-... 58
CVT500 138 GIR 230 … 83 GPB 3300 69 GZ-11 57 WD...D... 96
GIR 2002 86 GPF 100 49 WLAN 3100 112
DAkkS 7 GIR 2002 NS / DIF ... 88 GPH 114 47 HayTemp 285 16 WM500 137
DPP 15 103 GIR 2002 PID 86 GPH … 49 WS...D... 96
GIR 300 84 GPHU 014 MP … 130 IR-CT 20 121 WP...D... 102
EAK 36 85 GIR 360 85 GR 1... 49 ISO-WP … 7
EASYBUS.DLL 78 GITT 01 … 119 GR 10 103 ZOT 369 57
Logger / EASYBus
EASYControl net 76 GKF 125 21 GRA 010 VO 101 K 50.. 72
EASYLOG 24-RFT 108 GKF 250 22 GRA 0420 VO 101 KCL 3 M 47
EASYLOG 40BIN 110 GKK … 72 GRA 010 WK 101 KFZ 2000 81
EASYLOG 40IMP ... 109 GKL … 41 GRA 0420 WK 101 KM-1 ... / -3 ... 99
EASYLOG 40K … 107 GKV … 158 GRF 200 21 KM4P … 134
EASYLOG 40NS ... 109 GLF 100 … 43 GRHU … 122 KOH 100 50
EASYLOG 80CL 110 GLF 175 … 13 GRL 100 49 KTY 8 ... 159
EBS 20M / 60M 76 GLF 401 Mini 11 GRMU 2000 MP... 131
EBSK01 112 GLG 1300 74 GRO 200 … 154 LAN 3100 73
EBW … 112 GLI 9V 74 GRP 100 49 LC … 136
ecotach 71 GLMU … 132 GRV 100 58 LF … 41
EDT 24... 98 GLP 91 35 GRS 31 … 74 LF9648 93
EFF… 136 GLS 500 22 GS125 141 LFE ... 133
EL-USB-… 105 GMF 2... 22 GSA … 74
EPI 134 GMH 175 12 GSE 91 35 MAXVU... 97
Transmitter
ESA 100 58 GMH 11... 18 GSF ... 35 MINIDIN 4S 74
ESA 369 57 GMH 1170-Basic-SET 19 GSG 91 35 MINISOFT 75
EST… 158 GMH 1300 72 GSH 8922 71 MSD … 64
ET2011 98 GMH 2710 … 14 GSKA 3600 50 MSK 100 58
GMH 285 ... 12 GSM-3000 112 MT 400 24
FCM… 135 GMH 3000.DLL 78 GSMU … 127 MU 500 … 120
FH-Messing Flach 134 GMH 3111 … 61 GSOFT 40K 77
FHK… 135 GMH 3151 / 56 … 62 GSOFT 3050 77 NKU 1 … 158
FS3T 82 GMH 3161 / 81… 65 / 66 GSP 91… 35 NST 1… 158
FT500 143 GMH 32 … 17 GSS-F25 170
GMH 3210-Universal-SET 19 GSS-1 163 OB-700 157
G4P 159 GMH 33 … 28 GST ... 35 OXY 36 … 129
Temperature probe
GAD 1 BNC 49 GMH 34... 42 GST 3810 37
GAF 200 21 GMH 35 … 45 GT1-CO 128 P2P, P4P 159
GAK 9 V 74 GMH 3611 / 51 52 GT10-CO2-1R 128 PG 13.5 49
GAK 1400 47 GMH 369 … 55 GTD 1100 69 pH40 143
GAM 3000 74 GMH 3710 / 50 10 GTE 130 OK 22 pH9648 92
GAS 100 58 GMH 3810 37 GTF 35 11 PHL … 47
GAS 3600 52 GMH 3830 / 51 34 GTF 38 36 Prandtl-Staurohr 61
GB 9 V 74 GMH 51 … 60 GTF 55 B 45 Profi Lab-Expert 78
GBF 1550 22 GMH 54 … 40 / 41 GTF 101 ... 148 / 149 Pt 100 ... 159
GBS … 126 GMH 55 … 46 / 47 GTF 101 - Ex 154 PW 25 33
GBSK 91 35 GMH 56... 50 GTF 101-5- … 147
GBSL 91 35 GMH 569... 54 GTF 101-N0 … 153 Rail adapter 117
GCO 100 58 GMI 15 32 GTF 102 150 rotaro3 71
GDH 200 … 68 GMK 38 35 GTF 102 - Ex 155 RT 420 … 118
GDUSB 1000 70 GMK 100 33 GTF 103 151 RW-015HKL 170
GDUSB FastView 78 GMK 210 33 GTF 103 - Ex 155 RWI-016 … 170
Simulator
GTF 1000 AL 20 STS 0… 29
GES 130 21 GNG 12/ ... 103 GTF 1200 … 20
GES 175 … 13 GNG 24/ ... 103 GTF 2000 13 T2P, T4P 159
GES 401 … 11 GNG 220 ... 103 GTH 175 PT … 15 T03 BU /WE 117
GES 500 21 GNG 8901 70 GTH 200 air 16 TA 888 N 70
GES 900 21 GNR 10 103 GTH 11 ... 18 TA9648 90
GEWAS 18 ... 165 GNS 20E ... 169 GTH 1150-Gourmet-SET 19 TF 101 … 156
GEWAS 191 … 167 GNS-1 163 GTH 2448/ … 81 TFS 0100 E 29
GEWAS 200 166 GNS-3P … 163 GTL 153 T-Logg 100 … 105
GEWAS 300 168 GNS-KIT 169 GTL 130 21 T-Logg 120 … 106
GFN-SET1 29 GNS-C … 170 GTMU - AP ... 115 T-Logg 160 … 106
175
futher information on www.greisinger.de
EN
PROFESSIONAL MEASUREMENT
Measuring | Controlling | Regulating
MADE IN GERMANY
Product catalog
201
016
6
93128 Regenstauf | Hans-Sachs-Straße 26
+49 - 9402 - 9383 - 0 | www.greisinger.de
+49 - 9402 - 9383 - 33 | info@greisinger.de
01/2016