‫نبذة عن صاحب العمل‬ input data

‫ محمد الصعيدي‬.‫م‬ ‫ اإلسم‬:


24 ‫ العمر‬:
‫ الجنسية فلسطيني‬:
‫التخصص هندسة مدنية‬:
0598195411‫ رقم الجوال‬: input data
PD 70 ton
PL 50 ton
h
fc' 250 kg/cm2
fy 4200 kg/cm2
ρg 1.2 %
h ( short length ) 20 cm
b
Diameter of bars 14 mm
Diameter of strip 8 mm
concrete cover 4 cm

output data
Pu 164 ton
Ag 1211.4 cm2
b ( Lond length ) 60.6 cm Taken as 65 cm
Ag ( NEW ) 1300 cm2
ρg ( NEW ) 0.012 % check > ρ min 1
As 15.6 cm2 use 12 Ø 14 mm
As ( Used ) 18.5 cm2

Check Solution
i) Ceck spacing between ties

The spacing between ties equal 20 cm

ii) Ceck spacing between longitudinal bars

Sc 9.4 cm Check Sc > ( 4 & 1.5*db ) 1

Ties
Ø8 @ 20cm

Longitudinal bars

20 12 Ø 14

65

cross section