ISOLATED FOOTING DESIGN FOR (6' X 6' X12")

Footing Length,L = 6 Ft
Footing Width,B = 4 Ft
Footing Thickness, h = 12 in
Footing Effictive Thickness, d = 9 in
Concrete crushing strength,f'c = 3000 psi
Steel yield strength,fy = 50000 psi

200 b d
Minimun Steel As min =
fy
= 1.728 in²

Steel Area As = 1.728 in²


Select 16 mm ; Ab= 0.311687 in2
As
No of Bar = = 5.544 Nos
Ab
Use ~ 6 Nos

= (L-0.5) x12 =
Spacing 8.4 in
Nos-1

Use 16mmØ @6"c/c Both way

16mmØ @6"c/c Bothway

16mmØ @6"c/c Bothway


ISOLATED FOOTING DESIGN FOR (6' X 6' X12")

Footing Length,L = 4.5 Ft


Footing Width,B = 4.5 Ft
Footing Thickness, h = 9 in
Footing Effictive Thickness, d = 6 in
Concrete crushing strength,f'c = 2500 psi
Steel yield strength,fy = 40000 psi

200 b d
Minimun Steel As min =
fy
= 1.62 in²
SAFE
X direction Bottom Bar = 2.076 in²
Y direction Bottom Bar = 2.584 in²

Steel Area As = 2.584 in²


Select 16 mm ; Ab= 0.311687 in2
As
No of Bar = = 8.2904 Nos
Ab
Use ~ 9 Nos

= (L-0.5) x12 =
Spacing 6 in
Nos-1

Use 16mmØ @6"c/c Both way

16mmØ @6"c/c Bothway

16mmØ @6"c/c Bothway


ISOLATED FOOTING DESIGN FOR (6' X 6' X12")

Footing Length,L = 5.5 Ft


Footing Width,B = 5.5 Ft
Footing Thickness, h = 10 in
Footing Effictive Thickness, d = 7 in
Concrete crushing strength,f'c = 2500 psi
Steel yield strength,fy = 40000 psi

200 b d
Minimun Steel As min =
fy
= 2.31 in²
SAFE
X direction Bottom Bar = 3.25 in²
Y direction Bottom Bar = 3.423 in²

Steel Area As = 3.423 in²


Select 16 mm ; Ab= 0.311687 in2
As
No of Bar = = 10.982 Nos
Ab
Use ~ 11 Nos

= (L-0.5) x12 =
Spacing 6 in
Nos-1

Use 16mmØ @6"c/c Both way

16mmØ @6"c/c Bothway

16mmØ @6"c/c Bothway