You are on page 1of 6

S6D800-AK05-05 AC axial fan

sickled blades (S series)


with guard grille for short nozzle

ebm-papst Mulfingen GmbH & Co. KG


Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344

General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen


County court Stuttgart · HRB 590142

Nominal data

Type S6D800-AK05-05
Motor M6D138-LA

Phase 3~ 3~ 3~ 3~ 3~ 3~ 3~ 3~
Nominal voltage VAC 230 230 265 277 400 400 460 480
Connection Δ Δ Δ Δ Y Y Y Y
Frequency Hz 50 60 60 60 50 60 60 60

Type of data definition ml ml ml ml ml ml ml ml


State prelim. prelim.
Valid for approval / standard CE CE CE CE CE CE CE CE
Speed min-1 905 1030 1035 1085 905 1030 1035 1085
Power input W 1530 1960 1900 2160 1530 1960 1900 2160
Current draw A 5.98 6.6 6.32 6.7 3.46 3.82 3.65 3.87
Max. back pressure Pa 170 135 120 150 170 135 120 150
Max. ambient temperature °C 60 60 60 60 60 60 60 60
Starting current A 22 20 13 10 14
ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unit
Subject to alterations

Data according to ErP directive


Actual Request 2013 Request 2015

Installation category A Overall efficiency ηes 38.2 30.5 34.5


Efficiency category Static Efficiency grade N 43.7 36 40
Variable speed drive No Power input Pe kW 1.33
Specific ratio* 1.00 Air flow qv m³/h 15200
* Specific ratio = 1 + pfs / 100 000 Pa Pressure increase pfs Pa 122
Speed n min-1 920
Data established at point of optimum efficiency

Item no. 10191-5-9980 · Revision 76656 · Release 2012-03-27 · Page 1 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
S6D800-AK05-05 AC axial fan
sickled blades (S series)
with guard grille for short nozzle

Technical features

Mass 35.5 kg
Size 800 mm
Surface of rotor Cast in aluminium
Material of terminal box PC / ABS plastic
Material of blades Die-cast aluminum
Material of guard grille Steel, coated in black plastic (RAL9005)
Number of blades 5
Blade angle -5
Direction of air flow "V"
Direction of rotation Clockwise, seen on rotor
Type of protection IP 54
Insulation class "F"
Humidity class F3-1
Max. permissible ambient motor + 80 °C
temp. (transp./ storage)
Min. permissible ambient motor - 40 °C
temp. (transp./storage)
Mounting position Any
Condensate discharge holes On rotor and stator sides
Operation mode S1
Motor bearing Ball bearing
Touch current acc. IEC 60990 <= 3.5 mA
(measuring network Fig. 4, TN
system)
Electrical leads Via terminal box
Motor protection Thermal overload protector (TOP) brought out
Cable exit Axial
Protection class I (if protective earth is connected by customer)
Product conforming to standard EN 60034; EN 61800-5-1; CE
Approval UL 1004-1; CSA C22.2 Nr.100

Item no. 10191-5-9980 · Revision 76656 · Release 2012-03-27 · Page 2 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
S6D800-AK05-05 AC axial fan
sickled blades (S series)
with guard grille for short nozzle

Product drawing

1 Direction of air flow "V"


2 Tightening torque 1.5±0.2 Nm
3 Cable diameter: min. 7 mm, max. 14 mm, tightening torque: 2±0.3 Nm

Item no. 10191-5-9980 · Revision 76656 · Release 2012-03-27 · Page 3 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
S6D800-AK05-05 AC axial fan
sickled blades (S series)
with guard grille for short nozzle

Connection screen

Δ Delta connection Y Star connection L1 = U1 = black


L2 = V1 = blue L3 = W1 = brown W2 yellow
U2 green V2 white TOP 2 x grey
PE green/yellow

Item no. 10191-5-9980 · Revision 76656 · Release 2012-03-27 · Page 4 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
S6D800-AK05-05 AC axial fan
sickled blades (S series)
with guard grille for short nozzle

Charts: Air flow 50 Hz


Druck p f s[Pa]für Rho=1,2kg/m^3

qv[cfm]
0 2.000 4.000 6.000 8.000 10.000 12.000 14.000
250 1

240
0,95
230
0,9
220
Measurement: LU-101334
210 0,85
Air performance measured as per ISO 5801
200 0,8 Installation category A. For detailed
190 information on the measuring set-up, please
0,75 contact ebm-papst. Suction-side noise
180 levels: LwA measured as per ISO 13347 /
4 0,7 LpA measured with 1m distance to fan axis.
170 The values given are valid under the
0,65 measuring conditions mentioned above and
160 may vary according to the actual installation
150
situation. With any deviation from the
0,6
standard set-up, the specific values have to
140 be checked and reviewed with the unit

p fs_E[IN H2O]
0,55 installed.
130
pf s[Pa]

0,5
120

110 0,45
3
100 0,4

90
0,35
80
0,3
70

60 0,25

2
50 0,2

40
0,15
30
0,1
20
0,05
pf s

10
[Pa

1
0 0
]

0 2.000 4.000 6.000 8.000 10.000 12.000 14.000 16.000 18.000 20.000 22.000 24.000
qv[m^3/h]

Measured values
Conn. U f n Pe I LpAin LwAin qv pfs
V Hz min-1 W A dB(A) dB(A) m3/h Pa
1 Y 400 50 950 970 2.84 69 75 21560 0
2 Y 400 50 935 1148 3.02 65 72 19150 50
3 Y 400 50 925 1281 3.16 66 73 16590 100
4 Y 400 50 905 1530 3.46 69 76 12250 170
Conn. = Connection · U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · LpAin = Sound pressure level inlet side · LwAin = Sound power level inlet side
qv = Air flow · pfs = Pressure increase

Item no. 10191-5-9980 · Revision 76656 · Release 2012-03-27 · Page 5 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
S6D800-AK05-05 AC axial fan
sickled blades (S series)
with guard grille for short nozzle

Charts: Air flow 60 Hz


Druck p f s[Pa]für Rho=1,2kg/m^3

qv[cfm]
0 2.000 4.000 6.000 8.000 10.000 12.000 14.000 16.000
330
1,3
320
310 1,25
300 1,2
290
1,15 Measurement: LU-101330
280
1,1 Measurement: LU-101332
270
260 1,05 Air performance measured as per ISO 5801
250 1
Installation category A. For detailed
information on the measuring set-up, please
240 contact ebm-papst. Suction-side noise
0,95
230 levels: LwA measured as per ISO 13347 /
0,9 LpA measured with 1m distance to fan axis.
220
0,85
The values given are valid under the
210 measuring conditions mentioned above and
200 0,8 may vary according to the actual installation
190 situation. With any deviation from the
0,75 standard set-up, the specific values have to

p fs_E[IN H2O]
180 be checked and reviewed with the unit
0,7
installed.
pf s[Pa]

170
160 0,65
4
150 0,6
140 8 0,55
130
0,5
120
110 0,45
3
100 0,4
7
90 0,35
80
0,3
70
60 0,25
2
50 6 0,2
40 0,15
30
0,1
20
pf s ]
pf s

10 0,05
[Pa

5 1
[Pa

0 0
]

0 2.000 4.000 6.000 8.000 10.000 12.000 14.000 16.000 18.000 20.000 22.000 24.000 26.000 28.000
qv[m^3/h]

Measured values
Conn. U f n Pe I LpAin LwAin qv pfs
V Hz min-1 W A dB(A) dB(A) m3/h Pa
1 Y 480 60 1125 1604 3.26 72 79 25645 0
2 Y 480 60 1110 1820 3.49 69 76 23680 50
3 Y 480 60 1100 1994 3.68 68 74 21480 100
4 Y 480 60 1085 2160 3.87 69 75 19110 150
5 Y 400 60 1080 1494 3.08 71 78 24740 0
6 Y 400 60 1065 1654 3.34 68 75 22670 46
7 Y 400 60 1045 1818 3.60 66 73 20420 90
8 Y 400 60 1030 1960 3.82 68 74 18060 135
Conn. = Connection · U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · LpAin = Sound pressure level inlet side · LwAin = Sound power level inlet side
qv = Air flow · pfs = Pressure increase

Item no. 10191-5-9980 · Revision 76656 · Release 2012-03-27 · Page 6 / 6

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com