This document summarizes the programming fields for an alarm system. It includes sections for arming functions, zone responses, dialer programming, alarm and system status report codes, and options for exiting programming mode. Each field is identified by a number and contains instructions for what values or options can be programmed in that location.
This document summarizes the programming fields for an alarm system. It includes sections for arming functions, zone responses, dialer programming, alarm and system status report codes, and options for exiting programming mode. Each field is identified by a number and contains instructions for what values or options can be programmed in that location.
This document summarizes the programming fields for an alarm system. It includes sections for arming functions, zone responses, dialer programming, alarm and system status report codes, and options for exiting programming mode. Each field is identified by a number and contains instructions for what values or options can be programmed in that location.
i7 SYSTEM ARMING (‘20~~23) ‘20 MASTER SECURflY CODE .OclclU Enter 4 digits, O-9 ‘21 OulcK ARM ENABLE +I30 -no, 1 -yes ‘22 KEYSWITCH ENABLE +I3 rno.l -yes ‘23 FORCED BYPASS ENABLE +I30 -no,1 -yes ZONE RESPONSE PROGRAMMING (‘29=39) ‘30 AlARMBELLnMEoUT ++q O=n0na;l =4min;2-8min,3-12min ‘31 ZONE 1 RESPONSE TYPE q ZONE TYPES FOR PROGRAYUING FIELDS VI-37 0 (or undefined) = Zone Disabled ‘32 ZONE 2 RESPONSE TYPE cl 1 I ENTRY/EXIT. Burglary 2 I FIRE with timeout ‘33 ZONE 3 RESPONSE TYPE cl 3 - PERIMETER Burglary 4 I INTERlOR/FOLLOWER. Burglary ‘34 ZONE 4 RESPONSE lYPE cl 5 - TROUBLE BY DAY/ALARM BY NIGHT, Burglary 6 I 24 Hr (Silent) '35 ZONE 5 RESPONSE TYPE cl 7 I 24 Hr (Audiie) 8 I 24 Hr (Auxiliiry) '36 ZONE 6 RESPONSE TYPE El 9 I FIRE without timeout (Fields ‘35 and ‘37 only) '37 ZONE 7 RESPONSE TYPE cl CONSOLE PANIC. Only zone types 0,2,6,7,8.9 applicable. '38 ENTRY DELAY ++ c] 0=0sec,;1=20sec;2=30sac;3=45sec EXIT Delay = ENTRY Delay + 15 sac ‘39 ZONE3RESPONSETOOPEN + q 0~400msnominal;1=10msrmminal DIALER PROGRAMMING (*40-•47) l 40 PABX ACCESS CODE cl0cl0 Enter 4 digits. O-9. ff fewer than 4 digits entered. exit by pressing l (and press 41, if entering next field). To clear entries from field, press ‘40’. ‘41 PRIMARY PHONE No. nnnnnnnnnnnn Em upm 12dWs. O- 9. Do not fill unused spaces. ff fewer than 12 digits entered, exit by pressing l (and press 42, if entering next fiild). To dear entries fmm fiifd, press ‘41’. l 42 SECONDARY PHONE No. nnnnnnnnnnnri Enterupml2dk$s,O- 9. Do not fill unused spacxts. H fewer than 12 digits entered, exit by pressing l (and press 43, if entering next field). To dear entries from field, press ‘42’. ‘43 SUBSCRIBER ACCOUNT No. OOIIII Enter O-9; 6+11 for 8; kl2 for CM13 for D; 6+14 for E; #+15 for F. If only 3 diiits used, exit by pressing ’ (and press 44. if entering next field). To dear entries from field. press ‘43’. Exmpkw: For Accl No. 1224. enter: LT 121 131 14( For Acu No. 8234. enter: ) 121 131 141 For ~cct No. 123, enter: 1-i-l 121 m 1’1 ‘44 REPORTFORMAT Enter l as the 4th digit of ‘43 if 3+1 dialer reporting is to bs used. cl 0 = 3+1. kl ADEMCO Us STANOAR 6or-=4+2ADEMCOEXPRESS 1 - 3+1.4+1 R4DIoNlcs STANDARD 6 I 3+1.4+1 ADEMCO U8 EXPANDED 2=4+2AoEMcoussTANDARo 9 = 3+1, kl RADIONICSEXFANDED 3 - 4+2 RADIONICS srANMRo l 45 PHONE SYSTEM SELECT fi OH Cent.Sta. ISNOTona WATS line: 0 -PulseDial; 1 -ToneDi If Cent. Sta. IS on a WATS fine: 2 I Pulse Dii, 3 I Tone Dial ‘46 FUTURE USE + 0 Enter 0. '47 15 SEC DLALER DELAY (BURG) + 0 0 = no, 1 I yes TO PROGRAM ALARM, SYSTEM STATUS, AND’ RESTORE RPT CODES (*70=74) RESTORE REPORT CODES (‘51-‘74): Wlth a 3+1 or 4+1 Standard Format: Enter a code ‘70 AIARM RESTORE RPT CODE El in the first box: l-9.0. B, C, 0, E, or F. Enter [#+lO] for 0, 2nd digit is automatically sent as the 2nd [#+ll] for B. [#+12] for C, [#+13] for 0, [#+14] for E, (r&15] digit of the zone alarm report code for F. programmed in ‘51-X9, if expanded or 4+2 A IO] (not [#+lO]) in the f&box will disable a report. reporting is selected. A [O] (nor [#+lO]) in the secondbox will result in automatic ‘71 TROUBLERESTORERPTCOOE Ilr[ advance to the next field when programming. Wlth an Expanded or 4+2 Format: Enter codes in ‘72 BYPASS RESTORE RPT CODE III both boxes (1st and 2nd digits) for 1-9, 0, or B-F. as de- scribed above. ‘73 AC RESTORE RPT CODE III A [O] (nor [#+lO]) in the second box will eliminate the ex- panded message for that report. l 74 LOWBATRESTORERPTCOM mr[ A (01 (nor f#+lOl) in both boxes will disable the report. DOWNLOAD INFO (+94=97) Examples: For Code 3 (Single Diiit). enter: v1 Fl l 94 DOWNLOAD PHONE No. For Code 32 (Two Diiits). enter: l- For Code 82 (Hexadecimal) enter: [m 1-2 121 qEntercloonnclclcllJocl UPto 12 digits, O-9. Do not fill unused spaces. ff fewer than 12 diiits entered, exit fiefd by pressing ALARM REPORT CODES (‘51-‘59) l (and press 95. if entering next field). To clear en- tries from field, press ‘94’. ‘51 ZONE 1 AJARM REPORTCODE mrj ‘96 lNlTlALlZES DOWNLOAD ID, SUBSCRfBER ACCOUNT No. FOR INflTAL DOWNLOAD ‘52 ZONE2AlARMREPOFlTCODE mr1 No entry required. ‘53 ZOf’IE3ALARMREPORTCODE mr( ‘97 ZEROS ALL PROGRAM FIELDS No entry required. ‘54 ZONE4ALAJ?MREPORTCODE III1 TO EXIT PROGRAM MODE (‘98 or l QQ) ‘55 ZONE5AlARMREFORTCODE [rl[ Press ‘98 or ‘99 ff exiting programming, or next field number if continuing. ‘56 ZONE6AfARMREPOfTrcoDE IlI[ ‘98 U(fT5PROGRAMMlNGMODEand preVenrs reentry by: Master Code + Code + 0. ‘57 ZoNE?kuAlwREPoKrcoDE Ill] ‘99 EXRS PROGRAMMING MODE and (Console Panic) aUows reentry by: Master Code + Code + 0. ‘56 ZoNE8ALARMREPoRTcQDE 1111 (Duress) * ‘59 zmEg~~-y=) III
SYS STATUS RPT CODES (*60-‘66)
‘60 TROUBLEREPORTCODE III ‘61 BYPASS REPORTCODE III ‘62 AC LOSS REPORT CODE ElII ‘63 LOW BAT REPORT CQDE III ‘64 TESTREPORTCQDE III ‘65 OPENREPORTCODE I ttt
‘86 CLOSE REPORT CODE I ttt
m 2nd diit is automatically sent as the user number if expanded or 4+2 reporting is selected.