Refer to the Installation and Setup Guide for detailed information on programming the LYNXR/LYNXR24 or
LYNXR-EN system. The Installation and Setup Guide includes full descriptions of all data fields.
UL LYNXR and LYNXR-EN are not intended for UL985 Household Fire applications unless a 24-hour
backup battery (P/N LYNXRCHKIT-HC) is installed.
Certain features differ between the LYNXR/LYNXR24 and the LYNXR-EN models. Verify the specific
! model being installed prior to the system programming.
-2-
TO LOAD A DEFAULT SET:
While in Program mode, press ✱97, then enter a number 1-4 corresponding to the default table desired. See the
Installation Instructions for the default tables. Enter 0 if you are not selecting a default table.
NOTE: The telephone numbers in Fields ✱41 and ✱42 are not affected by defaults.
TO EXIT PROGRAMMING MODE:
✱98 Exits programming mode and prevents re-entry by: Installer Code + 8+ 0 + 0. If ✱98 is used to exit
programming mode, system must be powered down, then press [*] and [#] within 50 seconds of power up
to re-enter programming mode.
✱99 Exits programming mode and allows re-entry by: Installer Code + 8 + 0 + 0 or: Power-up, then press [*]
and [#] within 50 seconds of power up.
DATA FIELDS
Field Function Programmed Values [ ] = Table 1 Default Values
-3-
Field Function Programmed Values [ ] = Table 1 Default Values
ZONE SOUNDS AND TIMING (✱ 31– ✱ 39)
✱31 SINGLE ALARM SOUNDING/ZONE † [0]
1 = yes, limit once per arming period (also applies to long range radio
output if “0” is selected in *91 field); 0 = no limit
UL installations = 0
✱32 FIRE SOUNDER TIMEOUT † [0]
0=timeout; 1=no timeout
✱33 ALARM BELL TIMEOUT † [1]
0 = none; 1=4 min; 2=8 min; 3=12 min; 4 = 16 min
UL installations = 1 (4 min) minimum
✱34 EXIT DELAY † [70]
|
00-99 = exit delay time (in seconds).
UL installations = 60 seconds max.
✱35 ENTRY DELAY 1 (zone type 01) † [30]
|
00-99 = entry delay time (in seconds);
UL installations = 45 seconds max.
✱36 ENTRY DELAY 2 (zone type 02) † [60]
|
00-99 = entry delay 2 time (in seconds);
UL installations = 45 seconds max.
✱37 AUDIBLE EXIT WARNING / † [1, 1]
QUICK EXIT
Exit Warn Quick Exit
0 = no; 1 = yes
✱38 CONFIRMATION OF ARMING DING
† [0]
0 = no; 1 = yes (when armed by self-contained keypad or RF)
2 = yes (when armed by RF keypad only).
✱39 POWER UP IN PREVIOUS STATE
† [1]
0 = no; 1 = yes; UL installations = 1
† Entering a number other than the one specified may give unpredictable results.
NOTE: Only a corporate installer can view/edit telephone numbers in Fields *41 and *42.
✱41 STANDARD PHONE NUMBER Not Viewable. Press ✻ + Field Number to advance to next field.
-4-
✱42 TWO WAY VOICE PHONE Not Viewable. Press ✻ + Field Number to advance to next field.
NUMBER
✱48 REPORT FORMAT for PRIM./SEC [7, 7] Note: Option 7 (ADEMCO Contact ID®) must
be selected for AVM.
Primary Secondary
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
† Entering a number other than the one specified may give unpredictable results.
-5-
Field Function Programmed Values [ ] = Table 1 Default Value
NOTES: (1) If pager is enabled (Options 6-9 in Field *49) the end user cannot use the “Follow me”, and “Follow me” reminder features.
(2) LYNX reports system status as a voice message.
✱49 CENTRAL STATION/PAGER [0]
REPORTING/FOLLOW ME
0 = Disable (Backup report only)
** Pager Message
TO CENTRAL STA. PHONE No. TO END USER PHONE No.**
A 7-digit code (plus optional 16-digit prefix) is
6 = All except Open/Close Alarms, Open/Close‡, Troubles
sent to the pager consisting of a 3-digit event code,
7 = All reports Alarms, Troubles
followed by 00 and a 2-digit user or zone number.
8 = All reports Alarms, Open/Close‡, Troubles
See Installation Instructions for an explanation of
9 = All except Open/Close Open/Close‡
the pager code, which takes the following form: ‡ Will report users 0, 5-8 or wireless
AAAAAAAAAAAAAAAA-EEE-00NN arm/disarm button zones 26-33; all other
zones and users do not report
TO CENTRAL STA. PHONE No. TO END USER PHONE No.
AAA… = optional 16-digits (see field *88) 10 = All except Open/Close Alarms, Open/Close‡, Troubles
EEE = 3-digit event code: 911 (alarm), 101 (open), 102 (close), 11 = All reports Alarms, Troubles
811 (trouble)
12 = All reports Alarms, Open/Close‡, Troubles
00 = always displayed
NN = 2-digit user number or zone number, depending on the 13 = All except Open/Close Open/Close‡
‡ Will report users 0, 5-8 or wireless
type of event (EEE) that ocurred. NN=00 indicates AC
loss, sytem lowbattery or low battery in 5827. arm/disarm button zones 26-33; all other
zones and users do not report
-6-
Field Function Programmed Values [ ] = Table 1 Default Value
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (✱59–✱76, & ✱89):
With a 3+1 or 4+1 Standard Format: Enter a code in the first box: 1–9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B,
"#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F.
A "0" (not "#+10") in the first box will disable a report.
A "0" (not "#+10") in the second box will result in automatic advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A "0" (not "#+10") in the second box will eliminate the expanded message for that report.
A "0" (not "#+10") in both boxes will disable the report.
With Ademco Contact ID Reporting: Enter any digit (other than "0") in the first box, to enable zone to report (entries in the
second boxes will be ignored).
A "0" (not "#+10") in the first box will disable the report.
Examples: For Code 3 (single digit), enter: 3 | 0
-7-
Field Function Programmed Values[ ] = Table 1 Default Value
✱75 RF XMTR LO BAT RST RPT CODE | [1,0]
✱76 TEST RESTORE RPT CODE | [0,0]
-8-
Field Function Programmed Values[ ] = Table 1 Default Value
✱91 LYNXR/LYNXR24 [4]
LONG RANGE RADIO/ALARM
0 = Long range radio only
AUDIO VERIFICATION
1 = AAV and remote phone control
(AAV)/REMOTE PHONE CONTROL 2 = Long range radio and remote phone control
4 = AAV only
Notes: (1) If long range radio is being connected alarm audio verification cannot be
used.
(2) In order to activate the remote phone access feature and defeat an
answering machine ensure that the correct ring detection count (“15”)
has been programmed in field *95.
(3) Remote phone session will be terminated if a report must be sent.
(4) If alarm audio verification mode is selected a long range radio cannot be
connected.
(5) Alarm audio verification will only function when Contact ID is selected
and cannot be used for UL installations.
(6) If an alarm will be reported to the end user phone number (6-8 or 10-12
in field *49) AAV cannot be used.
(7) If AAV is enabled, LYNX will automatically use the central station phone
number programmed in field *41. If AAV is not enabled LYNX will use
the phone number programmed in field *42.
(8) If AAV is enabled, reports will be sent to the two-way voice phone
number.
LYNXR-EN [4]
ALARM AUDIO VERIFICATION
0 = None
(AAV)/REMOTE PHONE CONTROL
1 = AAV and remote phone control
2 = remote phone control only
4 = AAV only
Notes: (1) No programming is required if connecting an ALARMNET 7845C device
because the option is always enabled.
(2) In order to activate the remote phone access feature and defeat an
answering machine ensure that the correct ring detection count (“15”)
has been programmed in field *95.
(3) Remote phone session will be terminated if a report must be sent.
(4) Alarm audio verification will only function when Contact ID is selected
and cannot be used for UL installations.
(5) If an alarm will be reported to the end user phone number (6-8 or 10-12
in field *49) AAV cannot be used.
(6) If AAV is enabled, LYNX will automatically use the central station phone
number programmed in field *41. If AAV is not enabled LYNX will use
the phone number programmed in field *42.
(7) If AAV is enabled, reports will be sent to the two-way voice phone
number.
✱92 NUMBER OF REPORTS IN ARMED [0]
PERIOD
0 = 10 Alarm/Alarm Restore Reports;
1 = Unlimited (UL installations = 0)
DOWNLOAD INFORMATION (*93,*94,*95)
✱93 FLEXIBLE CALLBACK [0]
0 = No flexible callback; 1 = Last digit flexible; 2 = Last 2 digits flexible;
3 = Last 3 digits flexible
✱94 DOWNLOAD PHONE NUMBER
Enter up to 20 digits, 0–9; #+11 for '✱'; #+12 for '#'; #+13 for a pause.
Do not fill unused spaces. If fewer than 20 digits entered, pressing ✱
advances to the next field. To clear entries from field, press ✱94✱.
Note: In UL installations, downloading may only be performed if a technician
is at the site.
-9-
Field Function Programmed Values [ ] = Table 1 Default Value
✱95 RING DETECT COUNT FOR [15]
DOWNLOADING/REMOTE PHONE
CONTROL MODE 0 = Disable Station Initiated Download; 1–14 = number of rings (1–9,
[#]+10 =10, [#] +11 =11, [#] +12 =12, [#] +13 =13, [#] +14 =14);
15 = answering machine defeat ([#] +15 =15)
✱96 INITIALIZE DOWNLOAD ID & No entry required
SUBSCRIBER ACCOUNT
✱97 SET ALL PROGRAM FIELDS TO Enter 1-4 to select from default tables 1-4
1 OF 4 SETS OF DEFAULT VALUES Enter 0 to abort.
✱98 EXITS PROGRAMMING MODE If ✱98 is used to exit programming mode, you can not enter the
(PREVENTS RE-ENTRY) Installer Code + 8+ 0 + 0 for re-entry. You must press "✱" and
"#" within 50 seconds of power up or from exiting Programming
mode to re-enter Programming mode.
Note: After exiting Program mode, the system takes up to 1 minute to reset.
To bypass the reset delay, press [#] + [0].
✱99 EXITS PROGRAMMING MODE Installer Code + 8 + 0 + 0
(ALLOWS RE-ENTRY) or:
Power-up, then press "✱" and "#" within 50 seconds of power
up or from exiting Programming mode.
Note: After exiting Program mode, the system takes up to 1 minute to reset.
To bypass the reset delay, press [#] + [0].
- 10 -
*56 ENHANCED ZONE PROGRAMMING
Use this mode to program zone information. Press *56 while in programming mode.
Notes: (1) Entering a number other than the one specified may give unpredictable results.
(2) You may find it convenient to adjust the volume setting before entering the Programming Mode. This will allow
you to clearly hear feedback announcements or system beeps.
ZONE NUMBER
A 0I Enter the 2-digit zone number to be programmed. The system will announce the Voice Descriptor for the
selected zone, if it is programmed. • Zone 1 = hard wire zone
[*] = Continue • Zones 2-25 = RF transmitter zones (only)
00 = exit zone programming mode; • Zone 26-41 = RF button zones (only)
upon exiting, the prompt “56” blinks; press • Zone 92 = Duress
[*] + any field number to go to that field. • Zone 95, 96, 99 = Panic zones
ZONE TYPE
b zt Enter the 2-digit zone type (zt) for this zone (see table of zone types on worksheet).
[*] = Continue [if 00 is entered the system will skip to DELETE ZONE PARAMETERS prompt (F)].
[#] = Return to previous prompt
REPORT CODE
C rc Enter the report code (rc) for this zone.
Report consists of 2 hexadecimal digits, each composed of 2 numerical digits (A = 10, B = 11, C = 12, D
= 13, E = 14, F = 15; see Report Code description for explanation of codes).
[*] = Continue; If this is zone 1, 95, 96 or 99, the system skips to the VOICE DESCRIPTOR prompt (1C)
[#] = Return to previous prompt
INPUT TYPE
d i Enter the input type (i) for the transmitter assigned to this zone as follows:
Note
Zones 2-25 should be assigned
3 = Supervised RF (RF) [*] = Continue as Input Type 3 or 4 and Zones
4 = Unsupervised RF (UR) [#] = Return to previous prompt 26-41 should be assigned as
5 = Button type (BR) Type 5 only.
- 11 -
DELETE ZONE PARAMETERS
F 0 = Discard the delete request.
1 = Confirm the requested delete.
If 00 is entered in the zone type, confirmation of the delete request will delete all information associated
with zone currently being programmed.
If 0 is entered in the loop number, confirmation of the delete request will delete the serial number
associated with zone currently being programmed.
Note: 00 was entered as a zone type in prompt (b), 00 will be retained and system will advance to prompt (1C).
ENROLL MODE
IA LC 0 = Skip to the VOICE DESCRIPTOR prompt (1C). If zone type is “00,” then skips to DELETE SERIAL
NUMBER prompt instead.
1 = Enroll now and proceed to SERIAL NUMBER prompt (1b) (If “L” is not displayed).
2 = Copy the last serial number from the local memory buffer (If “L” is not displayed).
3 = View existing serial number. (Only if “L” is displayed).
9 = Delete existing serial number. (Only if “L” is displayed).
[*] = Advance to the VOICE DESCRIPTOR prompt (1C). This will save all zone parameters.
[#] = Return to the loop number prompt (E).
Notes: (1) “L” will be displayed only if transmitter was already learned.
(2) The system will announce the Voice Descriptor for the selected zone, if it is programmed, followed by
three beeps and “C” will be displayed only after confirmation.
SERIAL NUMBER
Ib Manually enter the transmitter’s 7-digit serial number (printed on the transmitter). If an incorrect digit is
entered, press the [#] key to return to prompt (1A).
Note: In order for all parameters to be accepted, you must advance to prompt (1C).
When all 7 digits are entered, press the [*] key. The serial number will be copied into EEROM and the
local memory buffer and the system will return to the (1A) prompt and “L” will be displayed. If 52 seconds
pass and no entry is been made, the system will return to prompt (1A).
VOICE DESCRIPTOR
IC 0 = Skip to next zone (A)
1 = Enter descriptor mode (existing zone descriptor will be announced, then descriptor 1 will be repeated)
DESCRIPTOR 1
Id vi Enter [#] + 2-digit vocabulary index† number (vi) of first descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 = accept word and advance to descriptor 2 (descriptor 2 will be announced)
8 = accept word and advance to next zone (prompt A) – zone descriptor will be announced
Press any other key to repeat the selected word
DESCRIPTOR 2
IE vi Enter [#] + 2-digit vocabulary index† number (vi) of second descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 = accept word and advance to descriptor 3 (descriptor 3 will be announced)
8 = accept word and advance to next zone (prompt A) – zone descriptor will be announced
Press any other key to repeat the selected word
DESCRIPTOR 3
IF vi Enter [#] + 2-digit vocabulary index† number (vi) of third descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 or 8 = accept word and advance to next zone (prompt A) – zone descriptor will be announced
Press any other key to repeat the selected word
† See *84 ASSIGN ZONE VOICE DESCRIPTORS section for Vocabulary Index.
- 12 -
*80 DEVICE PROGRAMMING
Use this mode to program Powerline Carrier Devices or zone lists for Chime by Zone feature. Press *80 while in
programming mode.
Note: Entering a number other than the one specified may give unpredictable results.
Device Programming
80 0 = Exit mode, upon which this prompt blinks.
1 = Enter mode
DEVICE NUMBER
A 0I Enter the 2-digit device number (01-08) to be programmed
[*] = Continue
00 = Exit Device Programming mode (displays blinking 80; enter * + desired data field or menu mode number)
DEVICE ACTION
b aa Enter the 1-digit action, 0-3, for the device being programmed (current action is displayed).
0 = No response 3 = Pulse on and off
1 = Close for 2 seconds [*] = Continue
2 = Close and stay closed [#] = Return to previous prompt
- 13 -
*81 ZONE LISTS
Use this mode to define zone lists for Powerline Carrier Devices and/or for the chime by zone feature. Press *81
while in programming mode.
Note: Entering a number other than the one specified may give unpredictable results.
DELETE ZONES
E Enter the 2-digit zone number to be deleted from the current zone list. When deleting a zone(s) from the
zone list, if the selected zone has a Voice Descriptor programmed, upon deletion it will be announced as
a confirmation that it has been deleted.
[*] = Delete zone and enter next zone to be deleted
00 = Return to next zone list number (prompt A 01)
- 14 -
*83 ENHANCED SEQUENTIAL MODE
Use this mode to enter transmitter serial numbers. Press *83 while in programming mode.
ZONE NUMBER
A 0I Enter the 2-digit zone number of the first transmitter to have its serial number entered. The system will
announce the Voice Descriptor for the selected zone if it has been programmed.
[*] = Continue; system searches for zones not yet entered, (for zones 2 to 25 a zone type must be
entered) then advances to ENROLL SERIAL NUMBER prompt (1b).
00 = Exit Sequential mode, upon which the prompt “83” blinks.
ENROLL MODE
IA zz 0 = Advance to next unlearned zone.
1 = Enter now and proceed to SERIAL NUMER prompt (1b). For 4-button keys (zones 26-29, 30-33, 34-
37 and 38-41) the serial number will be learned to all four buttons.
2 = copy the previous serial number entry from the buffer.
IA LC Notes: Before you can copy a serial number you must first enter a serial number. If no serial is stored in the buffer and
a copy is attempted the panel will emit a long beep indicating an invalid operation.
3 = View existing serial number. (Only if “L” is displayed. If “L” is not displayed, panel will emit a long
beep. Each digit will be displayed and the keypad will beep once for digits 1-6 and three times for last
digit.
4 = Copy the 4-button key template set for zones 26 - 29 (includes all zone parameters except serial
numbers). Only valid on 4-button key zones 30-33, 34-37 and 38-41 that do not have serial numbers
learned. (Template acceptance is indicated by two beeps after copying. A single long beep emitted when
copying templates indicates the template is not valid.)
9 = Delete existing serial number. Go to the (1A) prompt. (For 4-button key zones 26-29, 30-33, 34-37
and 38-41, deletes all four at once.)
[*] = Advance to the next unlearned zone.
[#] = Return to previous prompt (1A).
SERIAL NUMBER
Ib zz This prompt can be used to enroll the transmitter serial number via RF transmission or manually.
RF Learning - Two (2) transmissions (two key depressions at least five second apart) will be required for
BR type or four (4) transmissions (fault, restore and fault, restore) for UR or RF type. BR type devices
can be enrolled only by transmission from BR devices. Likewise, UR and RF devices can only be
Ib enrolled by transmission from a UR or RF device.
If the learned serial number has a different loop number than that entered in *56 the system will
announce the Voice Descriptor, if it is programmed, followed by two beeps and will return to Prompt (1A)
and “L” will be displayed.
If the loop number captured by RF transmission and that entered in *56 mode match, the system will
announce the Voice Descriptor, if it is programmed, followed by three beeps and return to Prompt (1A)
and “LC” will be displayed. No additional transmissions are needed for confirmation.
Manual Entry - Enter the 7-digit serial number printed on the transmitter. If you enter an incorrect digit,
press the [#] key to backup to prompt (1A) and start over. When all 7 digits are entered, press the [*] key.
If less than 7 digits are entered, the keypad will emit a single long beep and return to the (1A) prompt
without displaying the “L”. If more than 7 digits have been entered, the first 6 digits will be saved along
with the last digit that was entered (entering 123456789 yields the serial number 1234569).
Note: If 52 seconds passes and no entry has been made, the system returns to prompt (1A).
- 15 -
*84 ASSIGN ZONE VOICE DESCRIPTORS
Use this mode to assign voice descriptors for each zone. These are the descriptors that are announced when the
system announces any event involving a zone number. Press *84 while in programming mode.
Note: Entering a number other than the one specified may give unpredictable results.
ASSIGN ZONE VOICE DESCRIPTORS
84 0 = Exit mode, upon which this prompt blinks.
1 = Enter mode
ZONE NUMBER
A zz Enter the 2-digit zone number (zz) for which this descriptor is being assigned. The Voice Descriptor
for the selected zone will be announced, if it is programmed.
[*] = Continue to next prompt (existing descriptors will be announced, then descriptor 1 will be
repeated.)
00 = Exit Zone Voice Descriptor mode (displays blinking 84; enter * + desired data field or menu
mode number)
DESCRIPTOR 1
b vv Enter [#] + 2-digit vocabulary index number of first descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 = accept word and advance to descriptor 2 (descriptor 2 will be announced)
8 = accept word and advance to next zone (prompt A….zz) – zone descriptor will be announced
Press any other key to repeat the selected word
DESCRIPTOR 2
C vv Enter [#] + 2-digit vocabulary index number of second descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 = accept word and advance to descriptor 3 (descriptor 3 will be announced)
8 = accept word and advance to next zone (prompt A….zz) – zone descriptor will be announced
Press any other key to repeat the selected word
DESCRIPTOR 3
d vv Enter [#] + 2-digit vocabulary index number of third descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 or 8 = accept word and advance to next zone (prompt A….zz) – zone descriptor will be announced
Press any other key to repeat the selected word
VOCABULARY INDEX
ST
00 ½ sec pause F M S 29 1
ND
A 43 FAMILY ROOM 14 MAIN 64 SECOND FLOOR 30 2
RD
82 ALARM 87 FIRE 15 MASTER 65 SEVEN 31 3
32 ATTIC 44 FIRE DETECTION 54 MASTER 20 SHED
B 07 FIRST FLOOR BEDROOM 21 SHOP 70 Custom Word #1
01 BABY 45 FIVE 55 MEDICAL 66 SIDE 71 Custom Word #2
33 BACK 08 FLOOR 84 MESSAGE 67 SILENT POLICE 72 Custom Word #3
34 BASEMENT 46 FOUR 56 MOTION 68 SIX 73 Custom Word #4
35 BATHROOM 47 FRONT DETECTOR 69 SLIDING 74 Custom Word #5
36 BEDROOM G N 22 SMOKE 99 Blank (to erase previously
C 48 GARAGE 57 NINE 23 SOUTH programmed word)
83 CHECK 49 GUEST ROOM 16 NORTH 24 STORAGE
D 09 GUN 58 NURSERY 85 SYSTEM SYSTEM WORDS
(Announced by system –
37 DELAY DOOR H O T
not programmable)
38 DEN 50 HALL 59 OFFICE 25 THIRD FLOOR
AC LOSS
02 DETECTOR I 60 ONE 75 THREE
ARMED
03 DINING 10 INSIDE 17 OUTSIDE 76 TRANSMITTER
AWAY
39 DINING ROOM K P 77 TWO
BYPASSED
04 DOOR 51 KITCHEN 61 PATIO U
CHIME
40 DOWNSTAIRS L 62 POLICE 78 UPSTAIRS
DISARMED
05 DRIVEWAY 11 LAUNDRY 18 POOL 26 UTILITY
DISARM SYSTEM
E 52 LAUNDRY ROOM R 79 UTILITY ROOM
NOW
06 EAST 12 LIBRARY 63 REAR W
EXIT NOW
41 EIGHT 13 LIVING 19 ROOM 27 WEST
FAULT
42 EMERGENCY 53 LIVING ROOM 80 WINDOW
INSTANT
Y
LOW BATTERY
28 YARD
NOT
Z
READY TO ARM
81 ZERO
STAY
86 ZONES
- 16 -
*85 RECORD CUSTOM VOICE DESCRIPTORS
Use this mode to record up to 5 custom voice descriptors for use with zone announcements. Press *85 while in
programming mode.
NOTE: Entry of a number other than one specified will give unpredictable results.
RECORD CUSTOM VOICE DESCRIPTORS
85 0 = Exit mode, upon which this prompt blinks.
1 = Enter mode
0|6 | | | | |
0|7 | | | | |
0|8 | | | | |
0|9 | | | | |
1|0 | | | | |
1|1 | | | | |
1|2 | | | | |
1|3 | | | | |
1|4 | | | | |
1|5 | | | | |
1|6 | | | | |
-17-
Zone No. Zone Alarm Report Input Loop Transmitter Vocabulary
(A 01) Type (zt) Code in hex (rc) Type (I) No. (l) Serial Number Index
1|7 | | | | |
1|8 | | | | |
1|9 | | | | |
2|0 | | | | |
2|1 | | | | |
2|2 | | | | |
2|3 | | | | |
2|4 | | | | |
2|5 | | | | |
Button Zones
3|4 | | | | |
3|5 | | | | |
3|6 | | | | |
3|7 | | | | |
3|8 | | | | |
3|9 | | | | |
4|0 | | | | |
4|1 | | | | |
- 18 -
POWERLINE CARRIER DEVICES WORKSHEET FOR *80, and *81.
Applicable only if Powerline Carrier Devices are to be used, or chime-by-zone feature is used.
UL Powerline Carrier Devices are not UL Listed for fire or burglary functions and are intended for home
automation.
S T A R T S T O P
either or both either or both
DEVICE ACTION EVENT ZONE ZONE TYPE RESTORE ZONE TYPE/
NUMBER (aa) TYPE (et) LIST (zl) SYS OPERATION (zt) ZONE LIST (zl) SYS OPERATION (zt)
P.L.C.D.*† 01
P.L.C.D.*† 02
P.L.C.D.*† 03
P.L.C.D.* 04
P.L.C.D.* †05
P.L.C.D.*† 06
SYS. P.L.C.D.*† 07
SYS. P.L.C.D.*† 08 [2] [33] [36]
Note: If using an X-10 Powerhouse Security SH10A Siren as device 8, you must change the action default to “3” if using default table 4.
Where: A = DEVICE ACTION 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.
Note: Any zone in "ZT" going into alarm, fault, or trouble will
activate device with the exception of 01, 02 when the system
is in alarm. Any zone that restores will stop device action.
- 19 -
✱81 ZONE LISTS FOR OUTPUT DEVICES
Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the data
during the displays and prompts that appear in sequence.
Note: Record desired zone numbers below. More or fewer boxes than shown may be needed, since any list may include
any or all of a system's zone numbers.
Zone List 1: Started or stopped by zone numbers (enter 00 to end entries).
.etc. [28][32]
Zone List 3: Started or stopped by zone numbers AND/OR assignment of Chime zones (enter 00 to end entries)
.etc.[02][03]
LOOP 1
LOOP 2 (PRIMARY)
(REED) LOOP 2
LOOP 2 (REED)
(REED) LOOP 2
LOOP 1 LOOP 1 LOOP 1 (AUX.
(TERMINALS) LOOP 1 CENTER)
(TERMINALS) LOOP 1
(TEMP
ALTERNATE SENSOR) LOOP 3 LOOP 1 LOOP 1
POSITION (AUX. LOOP 3 (TERMINALS)
FOR LOOP 2 RIGHT) (TERMINALS)
5806/5807/5808/5808LST 5814 5816 5816MN 5816TEMP 5817 5818 5819
ENROLL AS "RF" ENROLL AS "RF" ENROLL AS "RF" ENROLL AS "RF" ENROLL AS "RF" ENROLL AS "RF" ENROLL AS "RF" ENROLL AS "RF"
1
LOOP 2 4
2
3
5
(REED) 7 6
8
*
0
9 LOOP 1 LOOP 1
LOOP 3 #
(SOUND) (MOTION)
(TERMINALS) LOOP 1
(INTERNAL
SHOCK (Green)
(Red)
SENSOR (Yellow)
Note: You must enroll loop 4 on the 5801, 5804/5804E, 5804BD/5804BDV and 5804WATCH transmitters, regardless of whether it is
used or not.
UL
The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5804E, 5804WATCH, 5808LST, 5814, 5816TEMP,
5819, 5819S(WHS & BRS), and 5850(GBD) transmitters are not intended for any UL installations.
SPECIAL MESSAGES
EE = Data Entry Error (invalid field number entered while programming; re-enter valid field number).
FC = Communication Failure
EA = Exit Alarm
CA = Cancel Alarm
CC = Modem Communication (system is in communication with the central station)
dI = Displayed approximately 4 seconds after powering up. This will revert to the Real-time Clock in approximately 1 minute and the green
“READY” LED should light. To bypass this delay, press: [#] + [0]. If “dI” remains displayed for more than one minute the system is
disabled.
PC = Remote phone control feature is active
PH = Speaker phone mode feature is active
90 = RF Jam
- 20 -
MONITRONICS LYNXR-EN PROGRAMMED VALUES
The following table summarizes the values have been programmed into the Monitronics LYNXR-EN at the factory and
replace the Table 1 values that are shown in the Installation Guide. Loading any other default table will override these
programmed values.
Function Entry Function Entry
*20 Installer code 4,1,1,2 *58 RF jam detection 0
*21 Quick arm enable 1 *59 Exit error report code 0
*22 Keypad backlight timeout 0 *60 Trouble report code 1,0
*23 Forced bypass 0 *61 Bypass report code 0,0
*24 RF house ID code 0,0 *62 AC loss report code 1,0
*25 Powerline carrier device house code 0 *63 Low battery report code 1,0
*26 Chime-by-zone 0 *64 Test report code 1,0
*27 Real-time clock display 1 *65 Open report code 0
*28 Not used --- *66 Arm away/stay report code 0,0
*29 Daylight saving time start/end month 4,10 *67 RF transmitter low battery report code 1,0
*30 Daylight saving time start/end weekend 1,5 *68 Cancel report code 0,0
*31 Single alarm sounding per zone 0 *69 Not used ---
*32 Fire sounder timeout 0 *70 Alarm restore report code 0
*33 Alarm bell timeout 1 *71 Trouble restore report code 1,0
*34 Exit delay 7,0 *72 Bypass restore report code 0,0
*35 Entry delay 1 (zone type 01) 3,0 *73 AC restore report code 1,0
*36 Entry delay 2 (zone type 02) 6,0 *74 Low battery restore report code 0,0
*37 Audible exit warning/quick exit 1,1 *75 RF transmitter low batt. restore report code 0,0
*38 Confirmation of arming ding 0 *76 Test restore report code 0,0
*39 Power up in previous state 1 *77 Not used ---
*40 PABX access code --- *78 Not used ---
*41 Standard phone number Not viewable *79 Not used ---
*42 Two way voice phone number Not viewable *80 Powerline carrier devices *80 table
*43 Standard subscriber account number 15,15,15,15 *81 Zone lists for devices *81 table
*44 Two way voice subscriber account number 15,15,15,15 *82 Not used ---
*45 Not used --- *83 Enhanced sequential mode *83 table
*46 End user telephone no. --- *84 Assign zone voice descriptor *84 table
*47 Phone system select 1 *85 Record custom voice descriptors *85 table
*48 Report format for Standard/Two-way 7,7 *86 Not used ---
*49 Central station/Pager reporting/Follow me 0 *87 Auxiliary function/ 1-button paging 0
*50 15 second dialer delay (burglary) 1 *88 Pager characters ---
*51 Periodic test report 3 *89 Event log 80% full report code 0,0
*52 First test report offset 3 *90 Event logging 15
*53 Sescoa/radionics select 0 *91 LRR/AAV/Remote Phone Control 4
*54 Lack of usage notification 0 *92 Number of reports in armed period 0
*55 Not used --- *93 Flexible call back 0
*56 Enhanced zone programming *56 table *94 Download phone number 1,8,0,0,6,8,2,1,6,9,0
*57 Not used --- *95 Ring detect count for downloading 15
Master User Code 1,2,3,4 Note: The defaults shown for fields *90 and *94 also apply to Tables 2 - 4.
- 21 -
*80 OUTPUT DEVICES
Start Stop
Zone Type Restore of Zone type
Device Number Action Event Zone List System Operation Zone List System operation
8 2 33 36
Note: Device numbers 1-7 have no default values
- 22 -
AAV / LRR
TRIGGER
(LYNXR/LYNR24)
LRR
WARNING: EARTH TRIGGER
TO PREVENT GROUND PHONE ZONE (LYNXR-EN) SOUNDERS PLCD AC
RISK OF
SHOCK
DISCONNECT 8 3 5 6 8 11 12 13 14 15 16
1 2 4 7 9 10
TELEPHONE POSITION
LINE AT TELECOM RJ11
JACK
JACK BEFORE TIP RING TIP RING (+) ( ) ( ) (+) ( ) (+) DATA SYNC
SERVICING OUT IN
THIS UNIT. HARD
WIRED
TO HANDSET INCOMING ZONE
PHONE PHONE
ALL OUTPUT LINE LINE
CIRCUITS
ARE POWER
LIMITED.
-23-
QUINICY, MA 02269). EARTH PREMISES UNSWITCHED
PIEZO
PRINTED INFORMATION DESCRIBING PROPER GROUND TELEPHONE OUTLET
INSTALLATION, EVACUATION PLANNING AND BELL
REPAIR SERVICE IS TO BE PROVIDED WITH THIS
EQUIPMENT. 2k OHMS 6-14VDC AC
EOLR 30mA max. 1332/1332X10/1332CN
6-14VDC CONNECTIONS
AC
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. 120mA max.
OPERATION IS SUBJECT TO THE FOLLOWING TWO WEEKLY TESTING IS (e.g. WAVE2EX) SYNC
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE REQUIRED TO ENSURE
HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST PROPER OPERATION COM
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING OF THIS SYSTEM
INTERFERENCE THAT MAY CAUSE UNDESIRED DATA 1332X10 ONLY
OPERATION. CONNECTIONS
PLUG-IN
THE LYNX SERIES CONTROLS ARE EQUIPPED WITH FCC ID: CFS8 DLLYNX (LYNXR/LYNXR24) AND TRANSFORMER
AN INTEGRAL RECHARGEABLE BATTERY PACK. CFS8DLLYNXREN (LYNXR-EN) COMPLIES WITH 9VAC, 15VA
LYNXR: P/N LYNXRCHKIT-SC FCC RULES, PART 68 FCC REGISTRATION
LYNXR24: P/N LYNXRCHKIT-HC No. 5GBUSA-25623-AL-E RINGER EQUIVALENCE: 0.6B
LYNXR-EN: P/N LYNXRCHKIT-SC
OR
P/N LYNXRCHKIT-HC
REPLACE EVERY FOUR YEARS
!"#$%#&'()*