You are on page 1of 3

TahoeDesignSoftware'sHYDROFLO2.

0 Marzo 21, 2023, 07:41 PM


Copyright 2005 (c) All Rights Reserved. www.tahoesoft.com Academic Version

Complete Report
Project file: sistemas de tuberia en serie.flo - Solved

Project Information Static Head Data


Project: sistema de tuberia en serie SourceElev: 40.00 ft
Client: Source Pressure: 0.00 psi
Engineer: Source HGL: 40.00 ft
Firm: Discharge Elev: 0.00 ft
Address: Discharge Pressure: 0.00 psi
Discharge HGL: 0.00 ft
Phone: Total Static Head: -40.00 ft
Fax:
email:

SystemInformation Liquid Properties


Pipe Head Loss Eq.: Darcy-Weisbach Water,Saturated at 80 deg F
Tolerance: 2.01E-06 cfs Temperature: 80.00 F
Atmospheric Press: 14.70 psi SpecificGravity: 0.99
Total Elements: 9 Viscosity: 9.15E-06 ft2/s
Total Parallels: 0 Vapor Pressure: 0.51 psi (abs)
Specific Heat: 1.00 Btu/lbF

Element Data by type...

Supplys: Pressure Elev Flow HGL


ID Type (psi ) (feet) (cfs ) In/Out (feet)
tanque elevado reservoir/tank (open) 0.00 40.00 0.95 out 40.00
Inlet/Exit: pipe inlet-inward projec, Elev=30.00 feet, dia=3.960 in, hl=0.64 psi
tanque 02 free discharge 0.00 0.00 0.95 in 0.00

Pipes: Length Fric Nom D In Dia Flow Direction Vel Head Loss
ID Spec (feet) (mlft) (inch) (inch) (cfs ) ->ID (ft/s) (psi )
tuberia 01 US04 30.00 0.150 4 4.020 0.95 ->codo 1 10.77 1.22
tuberia 02 US04 150.00 0.150 4 4.020 0.95 ->valvula 01 10.77 6.08
tuberia 03 US04 150.00 0.150 4 4.020 0.95 ->tanque 02 10.77 6.08
Pipe specifications...
US04 = Steel, Seamless,Sch 40, ANSI B36.10,B31.1

Valves & Fittings: Fric Diameter Flow Direction Head Loss


ID Description K (inch) (cfs ) ->ID (psi )
codo 1 Custom Fitting 0.34 4.026 0.95 ->manometro 01 0.26
codo de radio largo
valvula 01 Custom Valve 2.72 4.026 0.95 ->tuberia 03 2.09
entrada 01 Custom Fitting 1.00 4.020 0.95 ->tuberia 01 0.77
entrada del tanque 01

Gauges: Elevation Demand Pressure HGL


ID (feet) (cfs ) (psi ) (feet)
manometro 01 0.00 0.00 14.25 33.26

Element Data in sequence...

Elements in sequence Pressure Elev Head Change HGL


ID Type Desc (ftlq) (feet) (ftlq) (ftlq)
Start of Main Line - source side...
tanque elevado Supply reservoir/tank (open) 0.00 40.00 40.00
Inlet/Exit: Type=pipe inlet-inward projecting -1.49 37.01

Project file: sistemas de tuberia en serie.flo - Solved Page 1


TahoeDesignSoftware'sHYDROFLO2.0 Marzo 21, 2023, 07:41 PM
Copyright 2005 (c) All Rights Reserved. www.tahoesoft.com Academic Version

Element Data in sequence...

Elements in sequence Pressure Elev Head Change HGL


ID Type Desc (ftlq) (feet) (ftlq) (ftlq)
entrada 01 Fitt Custom Fitting -1.80 36.70
tuberia 01 Pipe Steel, Seamless,Sch 40, ANSI B36.10,B31.1 -2.84 33.87
codo 1 Fitt Custom Fitting -0.61 33.26
manometro 01 Gauge 33.26 0.00 33.26
tuberia 02 Pipe Steel, Seamless,Sch 40, ANSI B36.10,B31.1 -14.19 19.07
valvula 01 Valve Custom Valve -4.88 14.19
tuberia 03 Pipe Steel, Seamless,Sch 40, ANSI B36.10,B31.1 -14.19 0.00
tanque 02 Supply free discharge 0.00 0.00 0.00
End of Main Line - discharge side...

Project file: sistemas de tuberia en serie.flo - Solved Page 2


TahoeDesignSoftware'sHYDROFLO2.0 Marzo 21, 2023, 07:41 PM
Copyright 2005 (c) All Rights Reserved. www.tahoesoft.com Academic Version

Project: sistema de tuberia en serie Liquid: Water,Saturated at 80 deg F

Main Line (not to scale)

Project file: sistemas de tuberia en serie.flo - Solved Page 3