CABLE SINTOX Cu 600V 75°C Marketing


2AWG Phone: 318-240-5099
juan.benjumea@melexa.com

Nexans Ref.: 213560

Soft tempered copper conductor, insulated in LHFR-LS compound.

DESCRIPTION
Application
Cables for low voltage electrical energy distribution, installations in buildings, inside
premises, control panels and electronic circuits. Suitable for places with a high
concentration of people, where conductors with a low halogen content and low smoke
emission are required, which in the event of a fire will not generate toxic or corrosive
gases that may affect the health of people and the condition of equipment and
circuits electronics. The cables can be used for installations mentioned in NTC 2050
Article 310.

Suitable for installation in cable trays according to RETIE article 20.3, literal J, from 12
AWG gauge and larger.

Construction
Conductor
Soft copper conductor.

Insulation
Low halogen (LH – Low Halogen), flame retardant (FR – Flame Retardant), low smoke
emission (LS – Low Smoke) opaque, dense, toxic and corrosive thermoplastic
compound.

Applicable Standards
NTC 6182

Certificate
RETIE N° 07511

RETIE N° 05915

Operating Temperature
75°C

Operating Voltage
600V

Conductor flexibility Fire retardant Slightly halogenous


Class B IEC 60332-3-24 IEC 60754-1

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is
indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Generated 4/24/23 www.nexans.co Page 1 / 3
Contact
CABLE SINTOX Cu 600V 75°C Marketing
2AWG Phone: 318-240-5099
juan.benjumea@melexa.com

Marking

CENTELSA by NEXANS < Calibre AWG / Kcmil > Cu SINTOX LHFR-LS 600 V
75°C CT - HECHO EN COLOMBIA [M].

CHARACTERISTICS
Construction characteristics
Conductor flexibility Class B
Conductor material Soft copper
Conductor shape Compressed
Insulation Halogen free polyolefin
Dimensional characteristics
Approximate weight 372 kg/km
Conductor cross-section 33.6 mm²
Conductor diameter 7.2 mm
Nominal insulation thickness 1.52 mm
Nominal outer diameter 10.36 mm
Number of cores 1
Electrical characteristics
Ampacity 115.0 A
Max. DC resistance of the conductor at 20°C 0.532 Ohm/km
Operating voltage 600 V
Usage characteristics
Fire retardant IEC 60332-3-24
Reference -
RoHS conform -
Slightly halogenous IEC 60754-1

Conductor flexibility Fire retardant Slightly halogenous


Class B IEC 60332-3-24 IEC 60754-1

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is
indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.

Generated 4/24/23 www.nexans.co Page 2 / 3


Contact
CABLE SINTOX Cu 600V 75°C Marketing
2AWG Phone: 318-240-5099
juan.benjumea@melexa.com

TESTING CONDITIONS

• Ampacity to 75 °C conductor temperature, 30°C ambient temperature. No more than three current carrying
condutores in a duct or pipe. According to NTC 2050, Table 310.15(B)(16).
• The Data shown in the table are subject to normal manufacturing tolerances .

NOTE:

• The data reported here are nominal and are subject to tolerances according to standards and normal manufacturing
practices.
• Other configurations not specified in this catalog may be available under special request and minimum manufacturing
quantities.

All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is
indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Generated 4/24/23 www.nexans.co Page 3 / 3