You are on page 1of 9

REPEDE Pressure Control SRL

187 Mihai Bravu St. , Mizil , Prahova , Romania


Phone : +40(0)371081894, Fax : +40(0)372879455, e-mail : office@repede-group.com, VAT No. 25925118, RC J40/2428/2014

REVIEW REPORT
No. 6269.3 / 30.08.2021

Customer: S.C. UPETROM 1 MAI MANUFACTURING


Customer
Purchase Order or GOR 4400012430
Reference Number:
Job Number: ~

Item Description Serial No.

Prevenitor HYDRIL Annular GK 13 5/8 x 5000psi 151215

Reference Documents
API 16A
API 16AR
QM MANAGER :
Data book
Reviewed By: Ing. ARITEIA ILIE

TECHNICAL&QUALITY DIRECTOR:
Data book
Approved By:
Ing. DAN ZAMFIR

Date: 30.08.2021

F-001, rev.1/ 2012 This document and information contained herein are REPEDE Pressure Control
property and should not be used or copied without the company agreement
REPEDE Pressure Control SRL
187 Mihai Bravu St. , Mizil , Prahova , Romania
Phone : +40(0)371081894, Fax : +40(0)372879455, e-mail : office@repede-group.com, VAT No. 25925118, RC J40/2428/2014

Table of contents

Section 1 API & ISO certification:


- API 16A-0381 
- ISO 9001:2015 –00.12.0838
Section 2 Order acknowledgment:
Certificate of Conformity no. 6269.3 / 30.08.2021 
REPEDE Pressure Control’ Inspection Report no.6269.3 / 30.08.2021 

F-001, rev.1/ 2012 This document and information contained herein are REPEDE Pressure Control
property and should not be used or copied without the company agreement
REPEDE Pressure Control SRL
187 Mihai Bravu St. , Mizil , Prahova , Romania
Phone : +40(0)371081894, Fax : +40(0)372879455, e-mail : office@repede-group.com, VAT No. 25925118, RC J40/2428/2014

SECTION 1

F-001, rev.1/ 2012 This document and information contained herein are REPEDE Pressure Control
property and should not be used or copied without the company agreement
REPEDE Pressure Control SRL
187 Mihai Bravu St. , Mizil , Prahova , Romania
Phone : +40(0)371081894, Fax : +40(0)372879455, e-mail : office@repede-group.com, VAT No. 25925118, RC J40/2428/2014

F-001, rev.1/ 2012 This document and information contained herein are REPEDE Pressure Control
property and should not be used or copied without the company agreement
REPEDE Pressure Control SRL
187 Mihai Bravu St. , Mizil , Prahova , Romania
Phone : +40(0)371081894, Fax : +40(0)372879455, e-mail : office@repede-group.com, VAT No. 25925118, RC J40/2428/2014

F-001, rev.1/ 2012 This document and information contained herein are REPEDE Pressure Control
property and should not be used or copied without the company agreement
REPEDE Pressure Control SRL
187 Mihai Bravu St. , Mizil , Prahova , Romania
Phone : +40(0)371081894, Fax : +40(0)372879455, e-mail : office@repede-group.com, VAT No. 25925118, RC J40/2428/2014

SECTION 2

F-001, rev.1/ 2012 This document and information contained herein are REPEDE Pressure Control
property and should not be used or copied without the company agreement
REPEDE Pressure Control SRL
187 Mihai Bravu St. , Mizil , Prahova , Romania
Phone : +40(0)371081894, Fax : +40(0)372879455, e-mail : office@repede-group.com, VAT No. 25925118, RC J52/451/2009

INSPECTION REPORT
6269.3 / 30.08.2021

Product :
Prevenitor HYDRIL Annular GK 13 5/8 x 5000psi
Serial No. 151215

Purchasing order no. GOR 4400012430


Customer: GRUP SERVICII PETROLIERE OFFSHORE URANUS

Prepared by : Ariteia Ilie, Manager QM


Approved by : Dan Zamfir, Technical&Quality Director

Pg. 1 / 2
REPEDE Pressure Control SRL
187 Mihai Bravu St. , Mizil , Prahova , Romania
Phone : +40(0)371081894, Fax : +40(0)372879455, e-mail : office@repede-group.com, VAT No. 25925118, RC J52/451/2009

A. Evaluation of UPETROM’ documents


The 5 years inspection and certification of product
Prevenitor HYDRIL GK Annular 13 5/8 x 5000psi,
serial no. 151215, was performed by UPETROM according to the customer requirement specified in
contract no. GOR 4400012430 and consisting of:
1. Disassembly;
2. Inspection of parts;
3. Reassembly;
4. Hydrostatic tests;
5. Painting.
All documents issued by UPETROM, that are part of Data Book, were evaluated and their met the
specified requirements of customer contract no. GOR 4400012430.

All actions description in Report of Inspection and Actions / 08.07.2021 were done according to the
UPETROM’ technical specifications, applicable for this product.

No. Document Evaluation


1 Conformity Statement no. 146 / 18.08.2021 Ok
2 Report of inspection and actions / 08.07.2021 Ok
3 Measurement report Ok
4 Dye penetrant examination report Ok
5 Final inspection report / 10.08.2021 Ok

B. Hydrostatic Test Pressure of product


The product :
Validation Test
Products Serial No. Report

Prevenitor HYDRIL GK Annular 13 5/8 x 5000psi 151215 09.08.2021


have been tested according to the UPETROM’s pressure test specification and API 16A requirements.
The results recorded in UPETROM’s Performance Test Report / / 09.08.2021 are ACCEPTED.

C. Conclusion:
 Evaluation of UPETROM’ documents for 1 year inspection and certification of product: OK
 Hydrostatic Test Pressure of product acc. to API 16A specification: ACCEPTED

Pg. 2 / 2