You are on page 1of 3

‫ارﺗﻔﺎع اﻻﻋﻣدة‬

CL9003
BT9001
BT9000
BC9005

BT9001
00
90
BC9020

CL9000
BT
BC9022

01

BT
BT90
BC9007

00
CL9004

BT9001
BE9006

90
11
BE90

90
00
9
9 00

CL9001
BE9060

09

BT
BR

90
BE90
17

TR9003

TR
BE9010 BR
09
BE900
7 BE90 90
05 BE90
23 BC9008

00
BR9010 25
BE90

BT9001
BC9003
13

TR9002

90
BC9006 BR9005
90

BR

08
BC9021 BE90

BT
BR

90
02 BE9

CL9002
BR BE90 016

00

TR
BC9011 90

4
06 BE90 24
BC9013 22 BC9010 BC9009

TR9040
BE9026
006
BR9004 BR9

BT9007
BC9006

07
27 BR90 BE90
BE90

11
BC9015

TR9000
BT
08 03

90
90

TR
08

900
BE90

BR
90 BC9018 21
BE

5
1 8 32 BE90
BC9004 90 BE90 28 BE90

TR90
BC9012 BC9002 15
61 BE BE90
22 BC9006 BC9001
90 BR
90 BC9016
BC9014
BE

BT9006

0
12

TR9001
BT9
6
BE90 BC9002
34 BE9033 20

004
BE90

BR9007
BR9003
BE90
BC9019 BC9017 BC9006 21 BC9010
35

BT9
0
BE9 BE90

003
BC9001 19

BR
29

90
BE9031

90
EB9000

03
BE90

BE
BE9030 20
BE90
TR9005 13
BC9002

BE90
19
BE90
14

BE90
12
BC9002
H=VARIABLE

TR9003

TR9020
13
90

BE9048
TR9019 TR9021
BR

BT9005

TR9001
BT9007

BM9001 TR9022

BS9003
BE9058

047

BT9004

41
BS9004

BE9058
0 BR
90

0
TR9018 TR9036

BE9
BE

BS9001

BE9
TR9039 BR

BT9003
0

055
TR903006
BE9058
90
BT9006

BE9005
F/FR1

42

BE9
BE9004 TR9016
05

BS
PL9000

BE9046
90
BE

40
90

BS
BS

BS

02

51

0
90

BE9001

10

90
BM9003

BE9
90
43

0
TR9038

90

00
TR9032

BE9
08

056
BM9004

BS

7
PL9004

025

0
TR9031 PL9001

90
6 BM 9005

TR
BE9
00 BM9002 TR9015

BS
9

TR9
BS

901

NS/TR6
BE9053

4
BC9000 PL9001
TR9033

052
TR TR9028

013
BE

90 TR9035
27

039
BE9
90

057
TR

TR9
TR9034
44

TR9029
00 90

BE9
BE9049

37
BE9
90 24

0
BM

BE9
TR
BE

050
902
90

TR9011
45

BE9

038
TR9023

054
6

036
BE9

BE9

BE9
TR9037
TR9017
TR9012
CL9006

TR9000
TR9002
CL9008
CL9009

H = 98 mm

TR9010
H = 99 mm H = 102 mm

CL9007
H = 98 mm H = 98 mm H = 96 mm
TR9040

H = 99 mm
CL9011

H = 98 mm H = 100 mm H = 100 mm
H = 94 mm H = 99 mm FRONT- RIGHT
CL9005
H = 100 mm
H = 102 mm
H = 100 mm H = 100 mm

3D VIEW FOR NORTH & WEST


‫اﻟﺷﻣﺎﻟﻲ اﻟﻐرﺑﻲ‬
BT8002
000
BT8002

BT8
BC8020
BE8012

BT8
00
0
BR8009 BR8008 BE8014
BE8011 BC8018
BC8003 BE8007

BT 8 0
BE8056 TR8006 BC8004

02
BE8027 BE8006 BC8011 TR8004 TR8005
BC8019 BE8008 BE8019
BC8005
BE8024
BE8013
BC8009

BT80
BC8010
BC8008 BC8016 BE8029 01
80

BR8003
10 BR
800 BT BC8004

02
BT8006 80 7
BC8013 BE8025
BR BE8036 BE8
30 028
BE80 BE8002 BR8 BE8026
004 BC8006

BR
BC8000

TR
TE1 BC8017 BR8011 BC8014 BT8007

800
BC8012

80
BC8015 BR8003

03
BC8004 9

BT80
TE2 0
BE8037 80
BE80
3 9 BE BT BE
80

TR8009
2

02
8 18

800
BC8002 02 BE8031
BE8038 4 BC8000
BT8005

TR
BC8004
BE
80
BR8006 31 BR8002 BC8001 BE8032
BE

BR8002
BE8033 TR8000 80 8
BE8035
22 00 BE
BE8034
BT8 80
20
BC8000 BE BC8007
BE TR8008 80
80 03
16
BC8001
BC8000 BT8004 BE
H=VARIABLE

80
2 1
BT8003
BC8001
BE8014
BE TR8007
6 80
BE805 17 BE
80
BC8001 2B1E
BE 80
2 80 22
801 15
BR BR BE8
801 008
3
TR8019
BE8044 BS8003
TR8006 TR8017 TR80
18 BE
80
BE8005 19
BT8007 TR8035

BR
BT8006 TR8038 BS8004 BE8
004

8
BS8008

49

00
BE8065

5
80
BE8066
BS

BE
80

BT
TR8037
09

TR

BS8002
80
80 005
BR8
TR8

20

05
02 BM8005 BM8004
BM80
BE8045

BE

48
80
023

80
18

53

BE
BS8005

80
CL8010

TR8033 TR8032

BE8065
07

BE
TR8027 80 TR
BS TR 80
21 BR8005

BT
8 02 BM8000 BE

CL8008
BE8046

BS8006
EST/TR4

80
80

51
TR

BS8001
20

04
80

80
30

55
CL8009

TR8004

5
BE

2
BE

80

TR8005
80

52
80

BE
00

TR

80
TR8034

BE
TR8036 H = 97 mm
TR8031
24

H = 122 mm TR8014

BT
PL
80
TR80

BS8000 00

80
50
TR

03
57
TR

43
H = 145 mm BM
80
80

H = 126 mm 80

80
8

80
28 00
BE8047
26

BE

2
1

BE

BE

TR8009
1
80
TR

10
CL8006
H = 134 mm

80

13
H = 137 mm

BE
54
BM

TR80
80 80
H = 126 mm H = 103 mm 03

42
BE

TR

80
TR8016 TR 80
15

BE
80

CL8007
10
TR
80

09
22 H = 109 mm

80
CL8005

BE

NS/TR9
41
80
H = 115 mm

BE
H = 120 mm

63
TR

TR8001
H = 94 mm

80
8 01

BE
1

3D VIEW FOR SOUTH & EAST


H = 110 mm
H = 96 mm

40
80
BE
H = 100 mm
FRONT- RIGHT
H = 96 mm

‫اﻟﺟﻧوﺑﻲ اﻟﺷرﻗﻲ‬
STEEL NOTES:
1. UNLESS OTHERWISE INDICATED, ALL DIMENSIONS ARE IN MILLIMETERS AND

CL9003
BT9001
LEVELS IN METERS.

BT9000
2. ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE RELEVANT
ARCHITECTURAL, LANDSCAPE, CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL
BC9005 AND TELECOMMUNICATION ENGINEERING DOCUMENTS & PROJECT

BT9001
SPECIFICATIONS.
3. ALL DIMENSIONS ARE TO BE CHECKED AND VERIFIED PRIOR TO THE
COMMENCEMENT OF CONSTRUCTION ON SITE. DRAWINGS MUST NOT BE

00
SCALED. ONLY WRITTEN OR CONSOLIDATED DIMENSIONS SHALL BE USED.

90
BC9020 4. STRUCTURAL METAL WORK SHALL CONFORM TO

CL9000
BT
BC9022 REQUIREMENTS OF SPECIFICATIONS.
5. ALL STRUCTURAL STEEL PLATES SHALL CONFORM TO A36, Min fy = 240 MPA
. UNLESS OTHERWISE MENTIONED.

01
6. BOLT AND BOLTED CONNECTION SHALL CONFORM TO THE REQUIREMENTS OF

BT
THE "SPECIFICATION FOR STRUCTURAL JOINTS USING .

BT90
BC9007

CL9004

00

BT9001
BE9006

90
7. BOLT HOLE IN STEEL SHALL BE 3MM LARGER DIAMETER THAN NOMINAL SIZE
11
BE90

90
00
OF BOLT USED EXCEPT AS NOTED.
9

CL9001
900 BE9060

09
8. WELD LENGTHS CALLED FOR ON PLANS ARE THE NET EFFECTIVE LENGTH

BT
BR

90
BE90 REQUIRED. WELD SIZE ARE THE WIDE OF THE HORIZONTAL OR VERTICAL LEG
17

TR9003

TR
WHERE LENGTH OF THE WELD IS NOT SHOWN. IT SHALL BE FILLET WELD 3/4
BE9010 BR
09 OF PIPE THICKNESS AND IN FULL LENGTH OF JOINT.
BE90
07 BE90 9 00
5
BE90
23 BC9008
9. CONNECTIONS SHALL BE WELDED OR BOLTED WITH HIGH-STRENGTH BOLTS
UNLESS OTHERWISE NOTED.

0
BR9010 2 5
BE90

BT9001
10. WELDING WIRE WHEEL SHALL CONFORM TO E70XX.

00
13 BC9003

TR9002
BC9006 BR9005
90

9
BR

08
BC9021 BE90 PROJECT NOTES:

BT
BR

90
02 BE9

CL9002
BR BE90 016

00

TR
·
BC9011 90

4
06 BE90 24
BC9013 22 BC9010 BC9009 ·

TR9040
BE9026
006 ·
BR9004 BR9

BT9007
BC9006 ·

07
27 BR90 BE90
BE90

11
BC9015 ·

TR9000
BT
08 03

90
·

90

TR
08

900
BE90

BR
90 BC9018 21 ·
BE

5
1 8 32 BE90
BC9004 90 BE90 28 BE90 ·

TR90
BC9012 BC9002 15
61 BE BE90
22 BC9006 BC9001
90 BR
90 BC9016
BC9014
N
·
BE

BT9006

06
12

TR9001
BT9
·
BE90 BC9002
3 4 BE9033 20

004
·
BE90

BR9007
· Aluminum profiles are alloy 6063.
BR9003 ·
BE90
BC9019 BC9017 BC9006 21 BC9010
5
03

BT9
9
BE BE90

003
BC9001 19

BR
9
02

9
BE9031

00
EB9000

9
BE90

BE

3
BE9030 20
BE90
TR9005 13
BC9002

BE90
19
BE90
14

BE90
12
BC9002
TR9003

TR9020
3
9 01

BE9048
TR9019 TR9021
BR

BT9005

TR9001
BT9007

BM9001 TR9022

BS9003
BE9058

BT9004
047

041
BS9004

06

BE9058
BR
TR9018 TR9036 90
BE

BE9
90

BS9001

BE9
TR9039

BT9003
BR

055
TR903006
BE9058
90
BT9006

BE9005
42

BE9
BE9004 TR9016
05

BS
PL9000
BE9046
90
BE

40
90

BS
BS

BS

02

51
90

0
BE9001

10

9
BM9003

BE9
90
43

00
0
TR9038

90
TR9032

BE9
08

056
BM9004

BS

07
025 TR9031 BM 9100 PL9001

90
6

TR
BE9
00 BM9002 TR9015

BS
9
TR9

BS

901
BE9049 BE9053

4
BC9000 PL9001
TR9033

052
TR TR9028

013
BE

90 TR9035
27

039
BE9
90

057
TR

TR9
TR9034
44

00 90 TR9029

BE9

037
BE9
90 2 4
BM

BE9
TR9
BE

050
90

026

TR9011
45

BE9

TR9023

038

054

036
BE9

BE9
00 Issue for Approval 08-06-2022
REVISION. DESCRIPTION. DATE.

BE9
TR9037 OWNER:
TR9017
TR9012
CL9006

TR9002
CL9008
CL9009

B20

MAIN CONTRACTOR: CONSULTENT:

TR9010
CL9007
TR9040

CL9011

SUB-CONTRACTOR:
SHADE TECHNOLOGY FACTORY.CO.Ltd
Head Office: Riyadh Saudi Arabia.
CL9005

TR9000
P .O .Box 275144, Riyadh 11431
Tel.; +966 -11- 8122229
Fax.; +966 -11- 2633077

‫اﻟﺷﻣﺎﻟﻲ اﻟﻐرﺑﻲ‬
www.Steco.com.sa
E-mail: info@steco.com.sa
PROJECT TITLE:
SHABAB FC STADIUM
ERECTION

3D VIEW FOR NORTH & WEST DRAWING TITLE:

DRAWING No. SHEET No. REV.

CAD FILE No. DATE. SCALE. APPROVED BY.


00 15-03-2023 NTS NAN
DRAWN BY. CHECKED BY. CERTIFIED BY. DATE.
Ezz
SIGN. SIGN. SIGN. SIGN.

You might also like