Professional Documents
Culture Documents
MEASUREMENTS DATA
TEST DATA
MATERIAL DATA
HOLE DATA
INSTRUMENT DATA
The measurement uncertainties stated in this document were estimated as expanded uncertainty obtained
multiplying the standard uncertainty by the coverage factor k=2, that for a normal distribution, corresponding to a
confidence level of about 95%.
Depth εA ±U εA εB ±U εB εC ±U εC εD ±U εD
[mm] [µm/m] [µm/m] [µm/m] [µm/m] [µm/m] [µm/m] [µm/m] [µm/m]
0.050 13.2 2.3 13.3 2.3 12.7 2.3 / /
0.100 36.0 2.3 36.3 2.3 34.9 2.3 / /
0.150 66.9 2.5 67.8 2.5 65.9 2.5 / /
0.200 101.7 2.7 102.8 2.8 101.2 2.7 / /
0.250 135.0 3.1 135.8 3.1 134.8 3.1 / /
0.300 162.7 3.3 163.4 3.4 162.4 3.3 / /
0.350 183.8 3.6 184.8 3.6 183.1 3.6 / /
0.400 199.1 3.8 201.3 3.8 198.3 3.8 / /
0.450 210.7 3.9 214.6 4.0 210.2 3.9 / /
0.500 220.2 4.0 226.2 4.1 220.6 4.0 / /
0.550 228.5 4.1 236.6 4.2 230.0 4.1 / /
0.600 235.8 4.2 245.9 4.3 238.4 4.3 / /
0.650 242.3 4.3 254.1 4.5 245.5 4.3 / /
0.700 248.0 4.4 261.1 4.5 251.1 4.4 / /
0.750 253.2 4.4 267.5 4.6 255.6 4.5 / /
0.800 258.1 4.5 273.4 4.7 259.5 4.5 / /
0.850 262.8 4.6 278.9 4.8 263.0 4.6 / /
0.900 266.9 4.6 283.6 4.8 266.2 4.6 / /
0.950 270.1 4.7 287.2 4.9 268.7 4.6 / /
1.000 272.4 4.7 290.0 4.9 270.8 4.7 / /
εA εB εC εD
350.0
300.0
250.0
Residual strain [µm/m]
200.0
150.0
100.0
50.0
0.0
0.000 0.200 0.400 0.600 0.800 1.000 1.200
Depth [mm]
MEASUREMENT REPORT
ASTM E837-13 RESULTS
250.0 80.0
200.0
60.0
150.0
40.0
100.0
Residual stress [MPa]
Principal Angle [ ° ]
20.0
50.0
0.0 0.0
0.000 0.200 0.400 0.600 0.800 1.000 1.200
-50.0
-20.0
-100.0
-40.0
-150.0
-60.0
-200.0
-250.0 -80.0
Depth [mm]
σX σY τXY
50.0
0.0
0.000 0.200 0.400 0.600 0.800 1.000 1.200
Residual stress [MPa]
-50.0
-100.0
-150.0
-200.0
Depth [mm]
NOTE Several computed stresses significantly exceed 80 % of the material yield stress, then the results are
considered as indicative only. In general, the computed stresses whose values exceed 80 % of the
material yield stress tend to be overestimated.