44-1300 Series

Regulators - Pressure Reducing D44130549X012

Specifications
For other materials or modifications, please consult TESCOM.

OPERATING PARAMETERS
Pressure rating per criteria of ANSI/ASME B31.3

Maximum Inlet Pressure


  Stainless Steel Body
   4500 psig / 310 bar
   6000 psig / 414 bar available
  Brass Body
   3750 psig / 259 bar
   5000 psig / 345 bar available
Outlet Pressure Ranges
  0-300, 0-600, 0-1000 and 0-1500 psig DOME LOADED AIR LOADED
  0-20.7, 0-41.4, 0-69.0 and 0-103 bar
  0-2500 psig / 0-172 bar available
Design Proof Pressure
  150% of rated pressure
Leakage SPRING LOADED
  Bubble-tight
Operating Temperature1
  -15°F to 220°F / -26°C to 104°C TESCOM 44-1300 Series is a high pressure, high flow
pressure reducing regulator that offers a venting and
Flow Capacity2
  1/4" Main Valve: Cv = 0.8 balanced valve design. The 44-1300 Series provides Cv =
  3/8" Main Valve: Cv = 2.0 0.8 and 2.0. Dome and air load options are available.

MEDIA CONTACT MATERIALS Applications


Body • Commercial diving - breathing air
 Brass, 303 or 316 Stainless Steel
• Special gas mix regulation hard suit diving
Seat, Main Valve
  CTFE (Except: 44-13X2-XXX2, Teflon®) • High pressure tube trailer gas reduction
Seat, Vent Valve
  Teflon®: 300 and 600 psig / 20.7 and 41.4 bar outlet Features and Benefits
  CTFE: 1000 and 1500 psig / 69.0 and 103 bar outlet
• Large piston sensor gives excellent sensitivity
O-Rings
  Viton-A® • Balanced valve design ensures stable
Back-up Rings downstream pressure
  Teflon®
• Large handknob provides fast low-torque
Gaskets
pressure settings
  CTFE
Remaining Parts • Venting is standard
 300 Series Stainless Steel, 17-4, 17-7 Stainless Steel, Teflon®
and Brass
• Available with gauge ports
• Dome and air loaded models are available
OTHER (non-venting only)
Cleaning
  CGA 4.1 and ASTM G93
Weight (without gauges)
  6.25 lbs / 2.8 kg
1. For extended temperatures from -40°F to 400°F / -40°C to 204°C,
consult TESCOM.
2. A secondary pressure drop due to the outlet cross-hole can significantly
affect the rated flow capacity. Flow curves should be used for critical
sizing applications.
Teflon® and Viton® are registered trademarks of E.I. du Pont de Nemours
and Company.

www.tescom.com
44-1300 Series Regulator Drawing

Standard - 0 0 5 Modification
no gauge ports with gauge ports

All dimensions are reference & nominal


Metric [millimeter] equivalents are in brackets

2
44-1300 Series Regulator Flow Charts

For more information on how to read flow curves, please refer to the Flow Curves and Calculations document (debul2007x012) in the
TESCOM catalog or on www.tescom.com.

Cv = 0.8
1500 [103]
1400 [96.5]
OUTLET PRESSURE - psig [bar]

1300 [89.6]
1200 [82.7]
1100 [75.8]
1000 [69.0]
2000 psig [138 bar] INLET
900 [62.1]
800 [55.2]
700 [48.3]
2000
600 [41.4]
500 [34.5]
3000 psig [207 bar]
400 [27.6]
300 [20.7]
200 [13.8] 3000
100 [6.9] 1000 psig [69.0 bar]

0 200 400 600 800 1000 1200 1400 1600 1800 2000
[5663] [11,327] [16,990] [22,653] [28,317] [33,980] [39,644] [45,307] [50,970] [56,634]
FLOW RATE - SCFM [SLPM] Air

Cv = 2.0
1500 [103]
OUTLET PRESSURE - psig [bar]

1400 [96.5]
1300 [89.6] 3000 psig [207 bar] INLET
1200 [82.7]
1100 [75.8]
1000 [69.0]
900 [62.1]
2000 psig [138 bar]

800 [55.2]
2000
700 [48.3]
600 [41.4]
500 [34.5]
3000
400 [27.6]
2000
300 [20.7] 1000 psig [69.0 bar]
200 [13.8]
3000
100 [6.9] 2000
1000
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400
[5663] [11,327] [16,990] [22,653] [28,317] [33,980] [39,644] [45,307] [50,970] [56,634] [62,297] [67,960]
FLOW RATE - SCFM [SLPM] Air

3
44-1300 Series Regulator Part Number Selector

Repair Kits, Accessories & Modifications may be available for this product. Please contact TESCOM for more information.

Example for selecting a part number:


44-13 1 3 - 2 08 1

BASIC BODY INLET OUTLET


PORT TYPE PORT SIZE MAIN VALVE OPTIONS
SERIES MATERIAL PRESSURE PRESSURE RANGE

44-13  1  –  Brass     3750 psig   2  –  0-300 psig 1  –  SAE 08  –  1/2" 1  –  1/4" Cv = 0.8 - 002 Modification  –  Non-venting, no gauge ports
  259 bar       0-20.7 bar 2  –  NPTF 12  –  3/4" 2  –  3/8" Cv = 2.0 - 005 Modification  –  Venting with gauge ports
 2  –  303     4500 psig 3  –  0-600 psig 3  –  MS33649 - 019 Modification  –  Non-venting with gauge ports
     Stainless     310 bar       0-41.4 bar 9  –  BSPP - 056 Modification  –  6000 or 5000 psig / 414 or 345 bar inlet
     Steel   5  –  0-1000 psig                     pressure with 2500 psig / 172 bar
 6  –  316   4500 psig       0-69.0 bar                     outlet pressure
     Stainless   310 bar  6  –  0-1500 psig
- 183 Modification  –  Corrosion Resistant Top Works
     Steel          0-103 bar
   7  –  0-2500 psig
      0-172 bar
(-056 Mod only)

WARNING! Do not attempt to select, install, use or maintain this product until you have read and fully understood the TESCOM Safety,
Installation and Operation Precautions.

D44130549X012 © 2013 Emerson Process Management Regulator Technologies, Inc. All rights reserved. 07/2013.
Tescom, Emerson Process Management, and the Emerson Process Management design are marks of one of the Emerson Process
Management group of companies. All other marks are the property of their respective owners.

www.tescom.com
4

You might also like