Design and Function

1 8 5 6 2 9 5 8 10 2 1 7 6 4 7 3

1 Pinion shaft 6 Control piston Suction chamber


2 Internal gear 7 Radial pressure area Pressure chamber
3 Filler pin 8 Axial pressure area
4 Filler segment 9 Housing
5 Axial disc 10 End cover with bleeder screw

Function
Rotation of the gears within the pump draws in the pressure plates seal the pressure chamber with the minimal possible
fluid (usually hydraulic oil) into the space between the pinion gap. This design minimizes volume losses and increases
and internal gear. The two smooth running gears help to efficiency. When the gears rotate, the pinion teeth enter
ensure excellent intake behavior. the gaps between the internal gear teeth and displace the
pressure fluid.
In the radial direction, the gear chambers are sealed by gear
meshing and the filler piece. In the axial direction, the axial

Calculations

Delivery Q = Vg th · n · ηv · 10-3 [l / min]

Power Q · Δp
P= [kW]
600 · ηg

Vg th Pump volume per revolution [cm3]

n Speed [min-1]

ηv Volumetric efficiency

ηg Overall efficiency

Δp Differential pressure [bar]

2
Technical data

Design Internal gear pump with radial and axial sealing gap compensation

Type IPH

Mounting types SAE-hole flange; ISO 3019/1

Line mounting SAE-suction and pressure flange J 518 C Code 61

Rotation direction clockwise or counterclockwise

Mounting position any

Shaft load For details of radial and axial drive shaft loads,
please contact your Voith representative

Input pressure 0.8 … 3 bar absolute pressure (at start briefly 0.6 … 3 bar)

Pressure fluid HLP mineral oils DIN 51524, part 2 or 3

Viscosity range of the pressure fluid 10 ... 300 mm2s-1 (cSt)

Permissible start viscosity Max. 2 000 mm2s-1 (cSt)

Permissible temperature of the pressure fluid -20 ... + 80 °C

Necessary purity of the pressure fluid in accordance with NAS 1638 Class 8

Filtration Filtration quotient min. β20 ≥ 75, recommened β10 ≥ 100 (longer service life)

Permissible ambient temperature -10 ... + 60 °C

Characteristics

Speed Delivery Pressures within the range nmin … nmax

Displacement
Type, per revolution min. max. at 1500 min-1 Continuous pressure Peak pressure
size-
delivery [cm3] [min-1] [min-1] [l / min] [bar] [bar]

IPH 4 – 20 20.7 300 3 000 31.0 300 330

IPH 4 – 25 25.7 300 3 000 38.6 250 315

IPH 4 – 32 32.3 300 3 000 48.5 250 300

IPH 5 – 40 40.8 300 3 000 61.2 300 330

IPH 5 – 50 50.3 300 3 000 75.4 250 315

IPH 5 – 64 63.9 300 3 000 95.8 250 300

IPH 6 – 80 81.3 300 2 500 121.9 300 330

IPH 6 – 100 101.6 300 2 500 152.4 250 315

IPH 6 – 125 125.6 300 2 500 188.8 250 300

The values given apply for: Notes:

• Pumping of mineral oils with a viscosity of 20…40 mm2s-1 • Peak pressures apply for 15% of operating time and
• An input pressure of 0.8...3.0 bar absolute a maximum cycle time of 1 minute
• Please enquire about pressures lower than nmin
• Due to production tolerances, the pump volume may
be approx. 1.5 % lower

3
IPH Standard design 4, Rotation and Dimensions

Clockwise rotation 6 22 172


(cw)
0.3 ± 0.15 77 73 13 M10x15 146

8 h9

8.7
81
*

47.5

13.5
g
28
66.3

25 h7 37

h8
.6
20 M8x16

01
Z

ø1
c/2 c/2 e

Counterclockwise c
rotation (ccw)
h
l

k
i

A B

Permited input torques:


Input shaft A: 450 Nm
Sekundary shaft B: 300 Nm

Type / Dimensions and Weight SAE-Flange-No.


Delivery c e g h i k l m

[mm] [mm] [mm] [mm] [mm] [mm] Thread [kg]

IPH 4 – 20 102 36 19 30 58.7 30.2 M10 x 15 13.5 11 13

IPH 4 – 25 108 36 21 30 58.7 30.2 M10 x 15 14.2 11 13

IPH 4 – 32 116 36 24 32 58.7 30.2 M10 x 15 15.0 11 13


* The plug screw must be closed during operation. Ensure the M10x1 plug screw, hexagon socket SW5, is tightened to a torque of 10 Nm.
Depending on the pump position, filling or ventilation is possible with the M10x1 plug screw prior to commissioning.

Delivery Q Efficiency ηv and ηg

50 100

95
45 ηV
in l/min

90
Delivery Q inQ l / min

40
%
in %

ηg
85
Efficiency in
Wirkungsgrad

35
Förderstrom

80

30 75

25 70
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350

Betriebsdruck
Operating pressureppininbar
bar Operating pressure
Betriebsdruck p bar
p in in bar
Note: Measurement conditions:
Measurement taken in a low-noise room. Speed: 1500 min-1 / Viscosity of pressure fluid: 46 mm2s-1 /
In an anechoic room, the measurements are approx. 5 dB(A) lower. Operating temperature: 40 °C

4
IPH standard design 4, Designs

Rotation, suction
Type Pump sizes connection Mounting flange Shaft end
Standard
IPH 4 20 Clockwise rotation, SAE-2-hole-flange, dimensions on left Parallel shaft with
radial suction port
1 20 0 keyway connection, 64.5 1
dimensions on left
25

32 64.5

72.5 72.5

Variants
Counterclockwise Involute gearing with
rotation, 6 SAE-2-hole-flange 0
64
radial suction port
ANSI B92.1a
13T
16 / 32 DP 30 °

72

SAE-4-hole-flange
1 1
64.5 101.6 h8
42.5
13
12
8 h9
ø 78

124
90

28
25 h7
6
64.5
90
42.5 50 122
Involute gearing with
SAE-4-hole-flange 42
1

ANSI B92.1a
13T
16 / 32 DP 30 °

64

Designation according to type code


Type code / order designation, see page 13

Input power P Airborne noise level (Measurement site 1 m axial)

30 70

25
65
in dB(A)

20
Airborne noise
level in dB(A)
kW
in kW

15 60
Luftschallpegel
P in

10
Power P

55
Leistung

0 50
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350

Betriebsdruck
Operating pressure p in bar
bar Betriebsdruck
Operating pressure ppininbar
bar
Characteristic curves:
IPH 4 – 20 IPH 4 – 25 IPH 4 – 32

5
IPH Standard design 5, Rotation and Dimensions

Clockwise rotation 6 26.2 210


(cw) 0.3 ± 0.15 95 98 18 M10x15 181

10 h9

11.2
109
*

52.4

17.5
g
35
86.8

32 h7 44

h8
22 c/2 c/2 e

27
M12x25 Z

ø1
Counterclockwise c
rotation (ccw)
h
l

k
i

A B

Permited input torques:


Input shaft A: 800 Nm
Sekundary shaft B: 540 Nm

Type / Dimensions and Weight SAE-Flange-No.


Delivery c e g h i k l m

[mm] [mm] [mm] [mm] [mm] [mm] Thread [kg]

IPH 5 – 40 138 35 24 35 69.9 35.7 M12 x 19 26.8 12 30

IPH 5 – 50 145 35 27 42 69.9 35.7 M12 x 19 28.3 12 30

IPH 5 – 64 155 35 29 42 69.9 35.7 M12 x 19 30.0 12 30


* The plug screw must be closed during operation. Ensure the M10x1 plug screw, hexagon socket SW5, is tightened to a torque of 10 Nm.
Depending on the pump position, filling or ventilation is possible with the M10x1 plug screw prior to commissioning.

Delivery Q Efficiency ηv and ηg

100 100

95
90 ηV
in l/min

90
80
%
Delivery Q inQl / min

Efficiency inin%

ηg
85
Wirkungsgrad

70
Förderstrom

80

60
75

50 70
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350

Operating pressureppininbar
Betriebsdruck bar Operating pressureppininbar
Betriebsdruck bar
Note: Measurement conditions:
Measurement taken in a low-noise room. Speed: 1500 min-1 / Viscosity of pressure fluid: 46 mm2s-1 /
In an anechoic room, the measurements are approx. 5 dB(A) lower. Operating temperature: 40 °C

6
IPH standard design 5, Designs

Rotation, suction
Type Pump sizes connection Mounting flange Shaft end
Standard
IPH 5 40 Clockwise rotation, SAE-2-hole-flange, dimensions on left Parallel shaft with
radial suction port
1 22 0 keyway connection, 80 1
dimensions on left
50

64 80

89 89

Variants
Counterclockwise Involute gearing with
rotation, 6 SAE-2-hole-flange 80
0
radial suction port
ANSI B92.1a
14T
12 / 24 DP 30 °

89

SAE-4-hole-flange
80 ø127h8 1 1
16
56
10 h9
ø 100

189
ø 162

35
32 h7

6 80
17.5
56 55 189
Involute gearing with
SAE-4-hole-flange
56
1

ANSI B92.1a
14T
12 / 24 DP 30 °

80

Designation according to type code


Type code / order designation, see page 13

Input power P Airborne noise level (Measurement site 1 m axial)

60 75

50
70
Luftschallpegel in dB(A)

40
Airborne noise
level in dB(A)
kW
P PininkW

30 65

20
Leistung
Power

60
10

0 55
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350

Operating pressure
Betriebsdruck p inp bar
in bar Operating pressure pp in
Betriebsdruck in bar
bar
Characteristic curves:
IPH 5 – 40 IPH 5 – 50 IPH 5 – 64

7
IPH Standard design 6, Rotation and Dimensions

Clockwise rotation 5 35.7 264


(cw) 0.3 ± 0.2 120 121 20.5 M12x20 228.6

12 h9

13.7
135
*

69.9
g
43

22
106.3

40 h7 61

h8
26.5

.4
M12x25 Z

52
ø1
c/2 c/2 e

Counterclockwise c
rotation (ccw)
h
l

k
i

A B

Permited input torques:


Input shaft A: 1350 Nm
Sekundary shaft B: 800 Nm

Type / Dimensions and Weight SAE-Flange-No.


Delivery c e g h i k l m

[mm] [mm] [mm] [mm] [mm] [mm] Thread [kg]

IPH 6 – 80 171 49 32.5 50 77.8 42.9 M12 x 23 50.5 14 15

IPH 6 – 100 181 49 36 50 77.8 42.9 M12 x 23 54 14 15

IPH 6 – 125 193 47 39 50 77.8 42.9 M12 x 23 58 14 15


* The plug screw must be closed during operation. Ensure the M10x1 plug screw, hexagon socket SW5, is tightened to a torque of 10 Nm.
Depending on the pump position, filling or ventilation is possible with the M10x1 plug screw prior to commissioning.

Delivery Q Efficiency ηv and ηg

210 100

95
190 ηv
in l/min

90
Q l / min

Efficiency inin%%

170 ηg
85
Wirkungsgrad
Delivery Q in

150
Förderstrom

80

130 75

110 70
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350

Operating pressureppininbar
Betriebsdruck bar Operating pressure pp in
Betriebsdruck in bar
bar

Note: Measurement conditions:


Measurement taken in a low-noise room. Speed: 1500 min-1 / Viscosity of pressure fluid: 46 mm2s-1 /
In an anechoic room, the measurements are approx. 5 dB(A) lower. Operating temperature: 40 °C

8
IPH standard design 6, Designs

Rotation, suction
Type Pump sizes connection Mounting flange Shaft end
Standard
IPH 6 80 Clockwise rotation, SAE-2-hole-flange, dimensions on left Parallel shaft with
radial suction port
1 26,5 0 keyway connection, 104 1
dimensions on left
100

125 104

112.5 112

Variants
Counterclockwise Involute gearing with
rotation, 6 SAE-2-hole-flange 104
0
radial suction port
ANSI B92.1a
13T
8 / 16 DP 30 °

112,5

SAE-4-hole-flange
104 ø 152.4 h8
1 1
20 75.5
12 h9
ø 228.6
ø 130

264

43
40 h7

6 104
22
75.5 63 264 Involute gearing with
SAE-4-hole-flange 75.5 1

ANSI B92.1a
13T
8 / 16 DP 30 °

104

Designation according to type code


Type code / order designation, see page 13

Input power P Airborne noise level (Measurement site 1 m axial)

120 80

100
75
in dB(A)

80
Airborne noise
kW

level in dB(A)
Power PPininkW

60 70
Luftschallpegel

40
Leistung

65
20

0 60
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350

Operating pressure p in bar


Betriebsdruck Operating pressure pp inin bar
Betriebsdruck bar
Characteristic curves:
IPH 6 – 80 IPH 6 – 100 IPH 6 – 125

9
Suction and pressure flanges SAE J 518 C code 61, single-piece

1)
2)

A
C

k D
B
Wrench torque for screws according to ISO 6162
1)
Round seal ring (O-ring) ISO-R 1629 NBR
2)
Machine screw EN ISO 4762
3)
Special design, deviating from SAE J 518 C code 61

SAE-flange-No. A B C D E 1) i k S 2) max. pressure

Thread [mm] [mm] [mm] Seal ring [mm] [mm] Thread [bar]

10 G½ 46 54 36 18.66 – 3.53 38.1 17.5 M 8 345

11 G¾ 50 65 36 24.99 – 3.53 47.6 22.3 M 10 345

12 G1 55 70 38 32.92 – 3.53 52.4 26.2 M 10 345

13 G 1-¼ 68 79 41 37.69 – 3.53 58.7 30.2 M 10 276

14 3) G 1-½ 82 98 50 47.22 – 3.53 69.9 35.7 M 12 345 3)

30 G 1-½ 78 93 45 47.22 – 3.53 69.9 35.7 M 12 207

15 G2 90 102 45 56.74 – 3.53 77.8 42.9 M 12 207

16 G 2-½ 105 114 50 69.44 – 3.53 88.9 50.8 M 12 172

17 G3 124 134 50 85.32 – 3.53 106.4 61.9 M 16 138

18 G4 146 162 48 110.72 – 3.53 130.2 77.8 M 16 34

10
Multi-flow pumps, pump combinations, pump combinations in order of type and size

IPC 7 IPC 6 IPC 5 IPC 4 IPN 4


IPH 6 IPH 5 IPN 6 IPH 4 IPN 5 IPV 3
IPV 7 IPV 6 IPV 5 IPV 4 IPM 4

Combinations of IPC pumps Combination of IPC/IP… pumps

• IPC pumps of identical or different sizes can be combined • It is possible to combine IPC pumps with other Voith
to form multi-flow pumps. pump series (e.g. high-pressure pumps IPV or
• All sizes with each displacement low-pressure pumps IPN).
• are available as two or three-flow pumps; four-flow pumps • The pumps are arranged by type and size, as shown in
must be designed by Voith. the illustration above.
• The pumps are arranged in increasing order according to • If identical types or identical sizes follow each other,
size and delivery. the pump with the higher pump flow is placed closer
to the drive.

Selection Connection, assembly

1. Identify the pressure ranges and then choose • As a rule, multi-flow pumps are mounted to the drive using
the appropriate pump series. a flange. All information on flange designs and shaft ends
2. Identify the deliveries, and then select the is contained in the relevant pump series catalog.
appropriate size(s). • For further relevant information, such as how to determine
3. Define the sequence of the pumps. the adapter housing, see brochure No. G 1714
4. Check the torque. (Voith Multi-Flow Pumps).
5. Determine the direction of rotation and suction.
6. Specify the mounting flange and shaft end.

11
Designs

Rotation and suctions Mounting flange Shaft end

clockwise (cw) counterclockwise (ccw)

1 6

1 6 0 1 1 1 0

3 8

For designs and dimensions, For designs and dimensions,


3 8
see catalog for the relevant see catalog for the
pump series. relevant pump series.

Special design 4 9 Special design 0 SAE-2-hole-flange

1 SAE-4-hole-flange

12
Type code

IPH 5 – 50 1 0 1

Shaft end
0 Splined gear shaft ANSI B92.1a
1 Parallel shaft with keyway

Mounting flange
0 SAE-2-hole
1 SAE-4-hole

Rotation, suction port


1 Clockwise rotation, radial suction port
6 Counterclockwise rotation, radial suction port
4 Clockwise rotation, special design
9 Counterclockwise rotation, special design

Delivery
Sizes Available deliveries

4 20 25 32

5 40 50 64

6 80 100 125

Sizes
4 5 6

Type of internal gear pump

13
90115-IPH-DSH-EN-1509 ak  2015-09 Dimensions and illustrations without obligation. Subject to modifications.
This is a translated document. Original language: german.
Legally binding language version of document: german.

Voith Turbo H + L Hydraulic GmbH & Co. KG


Schuckertstraße 15
71277 Rutesheim, Germany
Tel. + 49 7152 992 3
Fax + 49 7152 992 4 00
sales-rut@voith.com
www.voith.de/hydraulik-systeme

You might also like