You are on page 1of 5

OEG BUIL DING M ATERIAL S - M ETAL FRAM ING M ANUFACTURERS

6001 BORDENTOWN AVE, SAYREVIL L E, NJ 0887 2

P 7 32.667.3636 I WWW.OEG USA.COM I ORDERS@ OEG USA.COM

PRODUCT MEMBER GAGE DESIGN METHOD


Composite Deck 15CD358 20 ASD

PHYSICAL PROPERTIES
Deck Type Composite Deck
Design Thickness 0.0358
Weight 2.01
Area 0.568
KSI 40
Coating G60
SECTION PROPERTIES
Ip (In4) 0.413
In (In4) 0.408
Sp (In3) 0.339
Sn (In3) 0.344

BARE DECK DESIGN 6 21/2


11/2
Bending Moment Positive (Mp/Ω) 5129
Bending Moment Negative (Mn/Ω) 5419
15/8
Shear Strength (Vn/Ω) 2417 36
Web Crippling OFE (Rbe/Ω) 920
Web Crippling OFI (Rbi/Ω) 1822

[ASD] MAXIMUM CONSTRUCTION CLEAR SPAN (ft-in.) FOR NORMAL WEIGHT CONCRETE 145 PCF

Slab Depth (in.) 1-SPAN 2-SPAN 3-SPAN 1-SPAN 2-SPAN 3-SPAN 1-SPAN 2-SPAN 3-SPAN
20 PSF CONSTRUCTION LOAD

50 PSF CONSTRUCTION LOAD

75 PSF CONSTRUCTION LOAD

3.5 (34 PSF) 6' 5" 7' 7" 7' 8" 6' 4" 6' 6" 6' 8" 5' 7" 5' 8" 5' 11"

4 (40 PSF) 6' 2" 7' 2" 7' 3" 6' 1" 6' 3" 6' 6" 5' 5" 5' 7" 5' 9"

4.5 (46 PSF) 5' 10" 6' 11" 7' 0" 5' 10" 6' 1" 6' 3" 5' 3" 5' 5" 5' 7"

5 (52 PSF) 5' 7" 6' 7" 6' 8" 5' 8" 5' 11" 6' 1" 5' 2" 5' 3" 5' 6"

5.5 (58 PSF) 5' 5" 6' 4" 6' 5" 5' 5" 5' 9" 5' 11" 5' 0" 5' 2" 5' 4"

6 (64 PSF) 5' 3" 6' 2" 6' 3" 5' 3" 5' 7" 5' 9" 4' 11" 5' 1" 5' 3"

NOTES
All section properties and strengths are reported per foot of panel width.
p = Property in positive bending; n = Property in negative bending.
Steel deck section properties were calculated in accordance with AISI S100-12.
Web crippling values are based on minmum bearing lengths of 1"1/2 for end bearing and 3" for interior bearing.

DISCAIMER:
All data, detail and speci cations included in herein are intended as a general guide for using OEG Building Materials products. These products should not be used in design or construction without
evaluation by a quali ed engineer or architect, to determine their suitability for a speci c use. OEG Building Materials assumes no liability for failure resulting f rom use or misapplication of computation,
details or speci cations contained herein. OEG Building Material assumes no liability for damages resulting f rom improper application or insulation of these products.
OEG BUIL DING M ATERIAL S - M ETAL FRAM ING M ANUFACTURERS

6001 BORDENTOWN AVE, SAYREVIL L E, NJ 0887 2

P 7 32.667.3636 I WWW.OEG USA.COM I ORDERS@ OEG USA.COM

[ASD] CANTILEVERED SPANS FOR NORMAL WEIGHT CONCRETE 145 PCF

Slab Depth (in.) 3.5 (34 PSF) 4 (40 PSF) 4.5 (46 PSF) 5 (52 PSF) 5.5 (58 PSF) 6 (64 PSF)

Span (ft-in) 2' 1" 2' 0" 2' 0" 1' 11" 1' 11" 1' 10"

[ASD] COMPOSITE DECK SLAB YIELD MOMENT FOR NORMAL WEIGHT CONCRETE 145 PCF

Slab Depth (in.) 3.5 (34 PSF) 4 (40 PSF) 4.5 (46 PSF) 5 (52 PSF) 5.5 (58 PSF) 6 (64 PSF)

Yield Moment (in-kip) 21.13 26.53 32.16 37.94 43.85 49.84

[ASD] ALLOWABLE UNIFORM LIVE LOADS FOR NORMAL WEIGHT CONCRETE 145 PCF

Slab Depth (in.) 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5

3.5 (34 PSF) 400 400 355 297 251 214 184 159 138 120 105 92 80 71 62 54
4 (40 PSF) 400 400 400 377 319 272 234 203 176 154 135 118 104 92 81 71
4.5 (46 PSF) 400 400 400 400 390 333 287 249 217 190 166 146 129 114 101 89
5 (52 PSF) 400 400 400 400 400 396 341 296 258 226 199 175 155 137 122 108
5.5 (58 PSF) 400 400 400 400 400 400 397 345 301 264 232 205 182 161 143 127
6 (64 PSF) 400 400 400 400 400 400 400 394 344 302 266 235 209 185 165 147

REINFORCEMENT FOR TEMPERATURE & SHRINKAGE


Overall Slab Depth (in.) Min. Welded Wire Reinforcement as per SDI Wire Area (in2 )
3.5 6X6 - W1.4X1.4 0.028
4 6X6 - W1.4X1.4 0.028
4.5 6X6 - W1.4X1.4 0.028
4.75 6X6 - W1.4X1.4 0.028
5 6X6 - W2.0X2.0 0.04
5.5 6X6 - W2.0X2.0 0.04
5.75 6X6 - W2.0X2.0 0.04
6 6X6 - W2.0X2.0 0.04

NOTES:
Load tables are calculated using section properties based on the steel design thickness.
Shoring requirements were established in accordance with SDI C-2011.
Bending Moment and De ection formulae are in accordance with ANSI/SDI C-2017.
Span length assumes clear spans. Center-to-center spacing of supports can be used for design as a conservative assumption.
Loads greater than 200 psf are usually the result of large concentrated dynamic loads. In such cases, contact OEG for additional
design information.

DISCAIMER:
All data, detail and speci cations included in herein are intended as a general guide for using OEG Building Materials products. These products should not be used in design or construction without
evaluation by a quali ed engineer or architect, to determine their suitability for a speci c use. OEG Building Materials assumes no liability for failure resulting f rom use or misapplication of computation,
details or speci cations contained herein. OEG Building Material assumes no liability for damages resulting f rom improper application or insulation of these products.
OEG BUIL DING M ATERIAL S - M ETAL FRAM ING M ANUFACTURERS

6001 BORDENTOWN AVE, SAYREVIL L E, NJ 0887 2

P 7 32.667.3636 I WWW.OEG USA.COM I ORDERS@ OEG USA.COM

PRODUCT MEMBER GAGE DESIGN METHOD


Composite Deck 3CD358 20 ASD

PHYSICAL PROPERTIES
Deck Type Composite Deck
Design Thickness 0.0358
Weight 2.1
Area 0.605
KSI 40
Coating G60
SECTION PROPERTIES
Ip (In4) 0.93
In (In4) 0.939
Sp (In3) 0.537
Sn (In3) 0.556

BARE DECK DESIGN 12

Bending Moment Positive (Mp/Ω) 12874


Bending Moment Negative (Mn/Ω) 13309
3

Shear Strength (Vn/Ω) 2413 4.97


Web Crippling OFE (Rbe/Ω) 493 36
Web Crippling OFI (Rbi/Ω) 1011

[ASD] MAXIMUM CONSTRUCTION CLEAR SPAN (ft-in.) FOR NORMAL WEIGHT CONCRETE 145 PCF

Slab Depth (in.) 1-SPAN 2-SPAN 3-SPAN 1-SPAN 2-SPAN 3-SPAN 1-SPAN 2-SPAN 3-SPAN
20 PSF CONSTRUCTION LOAD

50 PSF CONSTRUCTION LOAD

75 PSF CONSTRUCTION LOAD

5.5 (52 PSF) 10' 1" 10' 11" 11' 4" 9' 1" 7' 9" 8' 10" 7' 8" 6' 3" 7' 1"
6 (58 PSF) 9' 9" 10' 1" 10' 11" 8' 10" 7' 4" 8' 4" 7' 4" 6' 0" 6' 10"
6.25 (61 PSF) 9' 6" 9' 9" 10' 8" 8' 9" 7' 2" 8' 2" 7' 2" 5' 10" 6' 8"
6.5 (64 PSF) 9' 4" 9' 5" 10' 6" 8' 6" 7' 0" 7' 11" 7' 0" 5' 9" 6' 6"
7 (70 PSF) 9' 0" 8' 9" 10' 0" 8' 1" 6' 7" 7' 6" 6' 8" 5' 6" 6' 3"
7.25 (73 PSF) 8' 11" 10' 3" 10' 5" 7' 11" 6' 6" 7' 4" 6' 7" 5' 5" 6' 1"
7.5 (76 PSF) 8' 9" 8' 3" 9' 4" 7' 8" 6' 4" 7' 2" 6' 5" 5' 3" 6' 0"
8 (81 PSF) 8' 3" 7' 10" 8' 11" 7' 5" 6' 1" 6' 11" 6' 3" 5' 1" 5' 10"
8.25 (84 PSF) 8' 0" 7' 7" 8' 8" 7' 3" 5' 11" 6' 9" 6' 1" 5' 0" 5' 9"
8.5 (86 PSF) 7' 9" 7' 6" 8' 6" 7' 2" 5' 10" 6' 8" 6' 1" 5' 0" 5' 8"

NOTES
All section properties and strengths are reported per foot of panel width.
p = Property in positive bending; n = Property in negative bending.
Steel deck section properties were calculated in accordance with AISI S100-12.
Web crippling values are based on minmum bearing lengths of 2"1/2 for end bearing and 5" for interior bearing.

DISCAIMER:
All data, detail and speci cations included in herein are intended as a general guide for using OEG Building Materials products. These products should not be used in design or construction without
evaluation by a quali ed engineer or architect, to determine their suitability for a speci c use. OEG Building Materials assumes no liability for failure resulting f rom use or misapplication of computation,
details or speci cations contained herein. OEG Building Material assumes no liability for damages resulting f rom improper application or insulation of these products.
OEG BUIL DING M ATERIAL S - M ETAL FRAM ING M ANUFACTURERS

6001 BORDENTOWN AVE, SAYREVIL L E, NJ 0887 2

P 7 32.667.3636 I WWW.OEG USA.COM I ORDERS@ OEG USA.COM

[ASD] CANTILEVERED SPANS FOR NORMAL WEIGHT CONCRETE 145 PCF

Slab Depth (in.) 5.5 (52 PSF) 6 (58 PSF) 6.25 (61 PSF) 6.5 (64 PSF) 7 (70 PSF) 7.25 (73 PSF) 7.5 (76 PSF) 8 (81 PSF) 8.25 (84 PSF) 8.5 (86 PSF)

Span (ft-in) 3' 9" 3' 8" 3' 7" 3' 6" 3' 4" 3' 6" 3' 1" 3' 0" 2' 11" 2' 10"

[ASD] COMPOSITE DECK SLAB YIELD MOMENT FOR NORMAL WEIGHT CONCRETE 145 PCF

Slab Depth (in.) 5.5 (52 PSF) 6 (58 PSF) 6.25 (61 PSF) 6.5 (64 PSF) 7 (70 PSF) 7.25 (73 PSF) 7.5 (76 PSF) 8 (81 PSF) 8.25 (84 PSF) 8.5 (86 PSF)

Yield Moment (in-kip) 37.12 42.52 45.3 48.12 53.88 56.81 59.76 65.75 68.77 71.81

[ASD] ALLOWABLE UNIFORM LIVE LOADS FOR NORMAL WEIGHT CONCRETE 145 PCF

Slab Depth (in.) 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0

5.5 (52 PSF) 400 386 333 288 251 220 193 170 150 133 118 104 92 82 72
6 (58 PSF) 400 400 383 332 290 254 223 197 174 154 137 121 108 95 85
6.25 (61 PSF) 400 400 400 355 310 272 239 211 186 165 147 130 116 103 91
6.5 (64 PSF) 400 400 400 378 330 289 255 225 199 176 157 139 124 110 98
7 (70 PSF) 400 400 400 400 371 326 287 254 225 200 177 158 140 125 111
7.25 (73 PSF) 400 400 400 400 392 345 304 268 238 211 188 167 149 133 118
7.5 (76 PSF) 400 400 400 400 400 363 320 283 251 223 199 177 158 141 125
8 (81 PSF) 400 400 400 400 400 400 355 314 279 248 221 197 176 157 141
8.25 (84 PSF) 400 400 400 400 400 400 372 330 293 261 232 207 185 165 148
8.5 (86 PSF) 400 400 400 400 400 400 391 346 308 274 244 218 195 175 156

REINFORCEMENT FOR TEMPERATURE & SHRINKAGE


Overall Slab Depth (in.) Min. Welded Wire Reinforcement as per SDI Wire Area (in2 )
5.5 6X6 - W1.4X1.4 0.028
6 6X6 - W1.4X1.4 0.028
6.25 6X6 - W2.0X2.0 0.04
6.5 6X6 - W2.0X2.0 0.04
7 6X6 - W2.0X2.0 0.04
7.25 6X6 - W2.0X2.0 0.04
7.5 6X6 - W2.9X2.9 0.058
8 6X6 - W2.9X2.9 0.058
8.25 6X6 - W2.9X2.9 0.058
8.5 6X6 - W2.9X2.9 0.058

NOTES:
Load tables are calculated using section properties based on the steel design thickness.
Shoring requirements were established in accordance with SDI C-2011.
Bending Moment and De ection formulae are in accordance with ANSI/SDI C-2017.
Span length assumes clear spans. Center-to-center spacing of supports can be used for design as a conservative assumption.
Loads greater than 200 psf are usually the result of large concentrated dynamic loads. In such cases, contact OEG for additional
design information.

DISCAIMER:
All data, detail and speci cations included in herein are intended as a general guide for using OEG Building Materials products. These products should not be used in design or construction without
evaluation by a quali ed engineer or architect, to determine their suitability for a speci c use. OEG Building Materials assumes no liability for failure resulting f rom use or misapplication of computation,
details or speci cations contained herein. OEG Building Material assumes no liability for damages resulting f rom improper application or insulation of these products.

You might also like