You are on page 1of 11

SC-960-S-A1-DN-5021

STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0


DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN
Interface Shear Check and Design

Shear Check at interface showing the Section for Segment PS1, S1, S2, S3, S4

Page 36
SC-960-S-A1-DN-5021
STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0
DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN
Interface Shear Design in flange over Inner Web- Face of Web
Segment PS1 S1 S2 S3 S4 S5 S6 S6
280 Beam 4 5 6 7 8 9 10 11
281 Part I[4] I[5] I[6] I[7] I[8] I[9] I[10] I[11]
282 Distance from Pier Grid centre mm 1.4m 2m 5m 8m 11m 14m 17m Midspan
283 fck N/mm2 50 50 50 50 50 50 50 50
284 fcd =0.67/1.5 Fck N/mm2 22.33 22.33 22.33 22.33 22.33 22.33 22.33 22.33
285 fct N/mm2 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
286 fctd = fct/1.5 N/mm2 2.33 2.33 2.33 2.33 2.33 2.33 2.33 2.33
287 Interface Shear Design for Inner Webs
288 Calculate Effective width of Flange IRC 112 cl 7.6.1.2
289 bw web thickness mm 650 650 650 490 330 330 330 330
290 bi Left Refer Fig 9.1 of this document mm 1645 1645 1645 1645 1645 1645 1645 1645
291 bi Right mm 1715 1715 1715 1875 2035 2035 2035 2035
292 lo effective span for Simply Supported mm 38000 38000 38000 38000 38000 38000 38000 38000
293 beff left mm 1645 1645 1645 1645 1645 1645 1645 1645
294 beff Right mm 1715 1715 1715 1875 2035 2035 2035 2035
295
296 beff,total mm 4010 4010 4010 4010 4010 4010 4010 4010
297
298 Overal Depth of Slab Left mm 390 390 390 390 390 390 390 390
299 Overal Depth of Slab Right mm 540 540 390 390 390 390 390 390
300 Clear cover to Trans. Rlf. mm 35 35 35 35 35 35 35 35
301 Effective Depth of slab ..Assume 20mm Dia. Steel Left mm 345 345 345 345 345 345 345 345
302 Effective Depth of slab ..Assume 20mm Dia. Steel Right mm 495 495 345 345 345 345 345 345
303 Xu max = 0.456 d ..for Fe 500 Rlf. Steel Left mm 157 157 157 157 157 157 157 157
304 Xu max = 0.456 d ..for Fe 500 Rlf. Steel Right mm 226 226 157 157 157 157 157 157
305 `
311 hf Left hf mm 233 233 233 233 233 233 233 233
312 hf Right hf mm 314 314 233 233 233 233 233 233
313
314 Total Shear Force VED kN 11570 6578 4946 4042 5164 3773 2577 1099
315 Shear Force in Each inner Web For Above values Ref:- Corresponding Longitudinal Design note - SC-960-S-A1-DN-5021
= (VED x (b (inner web)) / (b inner web + b outer strut)
316
317 Shear Force in Each Inner Web VEd kN 4424 2515 1891 1435 1608 1175 802 342

IRC SP 105 section 8.3.4 Since there is a haunch on either sides of the web with a varying depth
v Ed = X . VEd . beff flange on one side And thus, the depth along the effective width is not constant
Z hf b total including web Instead of applying a reduction factor equal to the ratio of eff widths to total width
A reduction factor equal to the ratio of effective areas of flange has been applied
v Ed = X . VEd Aeff flange on one side
Z hf A total including web

Page 37
SC-960-S-A1-DN-5021
STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0
DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN

Effective area ratio


Left Haunnch Dimensions a1 mm 240 240 240 240 240 240 240 240
b1 mm 390 390 390 390 390 390 390 390
l1 mm 500 500 500 500 500 500 500 500
A1 mm2 157500 157500 157500 157500 157500 157500 157500 157500
Effective area to left of web A1ef mm2 432300 432300 432300 432300 432300 432300 432300 432300
Right Haunnch Dimensions a2 mm 540 540 240 240 240 240 240 240
b2 mm 540 540 390 390 390 390 390 390
l2 mm 815 815 500 500 500 500 500 500
A2 mm2 440100 440100 157500 157500 157500 157500 157500 157500
A2ef mm2 656100 656100 449100 487500 525900 525900 525900 525900

Aweb mm2 253500 253500 253500 191100 128700 128700 128700 128700

ATotal mm2 1341900 1341900 1134900 1110900 1086900 1086900 1086900 1086900
318 Z (Effective Depth) mm 2430 2430 2430 2430 1924 1924 1924 1924
319 vED(Left) IRC SP 105 section 8.3.4 N/mm2 2.52 1.43 1.27 0.99 1.43 1.04 0.71 0.30
320 vED(Right) v Ed = X . VEd . Aeff flange on one side N/mm2 2.83 1.61 1.32 1.11 1.74 1.27 0.87 0.37
321 Taking X = 1 Z hf A total including web

322 vRdmax θf = 45 IRC SP 105 Fig C 10.18 N/mm2 5.66 5.66 5.66 5.66 5.66 5.66 5.66 5.66
323
324 Hence whether vRdmax > vED(Left)/(Right) vED(Left) Left OK OK OK OK OK OK OK OK
325 vED(Right) Right OK OK OK OK OK OK OK OK
326
327 Is the Length of Flange under Compression Y/N Y Y Y Y Y Y Y Y
328 See Section 9.2 Row 31 Longi. Design Note

If Y, Min Strut Capacity θf = 26.50 vRdmin = 0.107fck(1-fck/310)


vRdmin 4.49 4.49 4.49 4.49 4.49 4.49 4.49 4.49
(N/mm2)
329
330 If N, Min Strut Capacity θf = 38.6 vRdmin = 0.130fck(1-fck/310) θfmin 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
331
VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin >
332 Check whether VRdmin > VEd Left
VEd VEd VEd VEd VEd VEd VEd VEd
VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin >
Right
333 VEd VEd VEd VEd VEd VEd VEd VEd
334
335 Hence for if VRdmin>VEd ,Take θf = 25.5 θf (Left) 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
-1
336 or θf = 0.5 Sin (vEd/0.135fck(1-fck/310)) θf (Right) 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
337 IRC 112 Eq 10.23
338 Calculating Transverse Asf/sf = vEd x hf Left mm2/mm 0.672 0.382 0.340 0.263 0.381 0.278 0.190 0.081
339 Reinforcement fyd Cot θf Right mm2/mm 1.020 0.580 0.353 0.297 0.463 0.339 0.231 0.099
Provide Provide Provide Provide Provide Provide Transvers Transvers
Interface Interface Interface Interface Interface Interface e e
Check whether vEd < 0.4 fctd Shear Shear Shear Shear Shear Shear Reinforce Reinforce
Reinforce Reinforcem Reinforce Reinforce Reinforce Reinforce ment ment
340 ment ent ment ment ment ment Sufficient Sufficient
341

Page 38
SC-960-S-A1-DN-5021
STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0
DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN
Interface Shear Design in flange over Inner Web- End of haunch
280 Beam 4 5 6 7 8 9 10 11
281 Part I[4] I[5] I[6] I[7] I[8] I[9] I[10] I[11]
282 Distance from Pier Grid centre mm 1.4m 2m 5m 8m 11m 14m 17m Midspan
283 fck N/mm2 50 50 50 50 50 50 50 50
284 fcd =0.67/1.5 Fck N/mm2 22.33 22.33 22.33 22.33 22.33 22.33 22.33 22.33
285 fct N/mm2 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
286 fctd = fct/1.5 N/mm2 2.33 2.33 2.33 2.33 2.33 2.33 2.33 2.33
287 Interface Shear Design for Inner Webs
288 Calculate Effective width of Flange IRC 112 cl 7.6.1.2
289 bw web thickness mm 650 650 650 490 330 330 330 330
290 bi Left Refer Fig 9.1 of this document mm 1645 1645 1645 1645 1645 1645 1645 1645
291 bi Right mm 1715 1715 1715 1875 2035 2035 2035 2035
292 lo effective span for Simply Supported mm 38000 38000 38000 38000 38000 38000 38000 38000
293 beff left mm 1645 1645 1645 1645 1645 1645 1645 1645
294 beff Right mm 1715 1715 1715 1875 2035 2035 2035 2035
295
296 beff,total mm 4010 4010 4010 4010 4010 4010 4010 4010
297
298 Overal Depth of Slab Left mm 240 240 240 240 240 240 240 240
299 Overal Depth of Slab Right mm 240 240 240 240 240 240 240 240
300 Clear cover to Trans. Rlf. mm 35 35 35 35 35 35 35 35
301 Effective Depth of slab ..Assume 20mm Dia. Steel Left mm 195 195 195 195 195 195 195 195
302 Effective Depth of slab ..Assume 20mm Dia. Steel Right mm 195 195 195 195 195 195 195 195
303 Xu max = 0.456 d ..for Fe 500 Rlf. Steel Left mm 89 89 89 89 89 89 89 89
304 Xu max = 0.456 d ..for Fe 500 Rlf. Steel Right mm 89 89 89 89 89 89 89 89
305 `
311 hf Left hf mm 151 151 151 151 151 151 151 151
312 hf Right hf mm 151 151 151 151 151 151 151 151
313
314 Total Shear Force VED kN 11570 6578 4946 4042 5164 3773 2577 1099
315 Shear Force in Each inner Web For Above values Ref:- Corresponding Longitudinal Design note - SC-960-S-A1-DN-5021
= (VED x (b (inner web)) / (b inner web + b outer strut)
316
317 Shear Force in Each Inner Web VEd kN 4424 2515 1891 1435 1608 1175 802 342

IRC SP 105 section 8.3.4 Since there is a haunch on either sides of the web with a varying depth
v Ed = X . VEd . beff flange on one side And thus, the depth along the effective width is not constant
Z hf b total including web Instead of applying a reduction factor equal to the ratio of eff widths to total width
A reduction factor equal to the ratio of effective areas of flange has been applied
v Ed = X . VEd Aeff flange on one side
Z hf A total including web

Page 36
SC-960-S-A1-DN-5021
STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0
DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN

Effective area ratio


Left Haunnch Dimensions a1 mm 240 240 240 240 240 240 240 240
b1 mm 390 390 390 390 390 390 390 390
l1 mm 500 500 500 500 500 500 500 500
A1 mm2 157500 157500 157500 157500 157500 157500 157500 157500
Effective area to left of web A1ef mm2 274800 274800 274800 274800 274800 274800 274800 274800
Right Haunnch Dimensions a2 mm 540 540 240 240 240 240 240 240
b2 mm 540 540 390 390 390 390 390 390
l2 mm 815 815 500 500 500 500 500 500
A2 mm2 440100 440100 157500 157500 157500 157500 157500 157500
A2ef mm2 216000 216000 291600 330000 368400 368400 368400 368400

Aweb mm2 253500 253500 253500 191100 128700 128700 128700 128700

ATotal mm2 1341900 1341900 1134900 1110900 1086900 1086900 1086900 1086900
318 Z (Effective Depth) mm 2430 2430 2430 2430 1924 1924 1924 1924
319 vED(Left) IRC SP 105 section 8.3.4 N/mm2 2.47 1.40 1.25 0.97 1.40 1.02 0.70 0.30
320 vED(Right) v Ed = X . VEd . Aeff flange on one side N/mm2 1.94 1.10 1.32 1.16 1.87 1.37 0.94 0.40
321 Taking X = 1 Z hf A total including web

322 vRdmax θf = 45 IRC SP 105 Fig C 10.18 N/mm2 5.66 5.66 5.66 5.66 5.66 5.66 5.66 5.66
323
324 Hence whether vRdmax > vED(Left)/(Right) vED(Left) Left OK OK OK OK OK OK OK OK
325 vED(Right) Right OK OK OK OK OK OK OK OK
326
327 Is the Length of Flange under Compression Y/N Y Y Y Y Y Y Y Y
328 See Section 9.2 Row 31 Longi. Design Note

If Y, Min Strut Capacity θf = 26.50 vRdmin = 0.107fck(1-fck/310)


vRdmin 4.49 4.49 4.49 4.49 4.49 4.49 4.49 4.49
(N/mm2)
329
330 If N, Min Strut Capacity θf = 38.6 vRdmin = 0.130fck(1-fck/310) θfmin 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
331
VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin >
332 Check whether VRdmin > VEd Left
VEd VEd VEd VEd VEd VEd VEd VEd
VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin >
Right
333 VEd VEd VEd VEd VEd VEd VEd VEd
334
335 Hence for if VRdmin>VEd ,Take θf = 25.5 θf (Left) 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
336 or θf = 0.5 Sin-1(vEd/0.135fck(1-fck/310)) θf (Right) 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
337 IRC 112 Eq 10.23
338 Calculating Transverse Asf/sf = vEd x hf Left mm2/mm 0.427 0.243 0.216 0.167 0.242 0.177 0.121 0.052
339 Reinforcement fyd Cot θf Right mm2/mm 0.336 0.191 0.229 0.201 0.325 0.237 0.162 0.069
Provide Provide Provide Provide Provide Provide Provide Transvers
Interface Interface Interface Interface Interface Interface Interface e
Check whether vEd < 0.4 fctd Shear Shear Shear Shear Shear Shear Shear Reinforce
Reinforce Reinforcem Reinforce Reinforce Reinforce Reinforce Reinforce ment
340 ment ent ment ment ment ment ment Sufficient
341

Page 37
SC-960-S-A1-DN-5021
STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0
DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN
Interface Shear Design in flange over Outer Web- Face of Web (Haunch Ignored)
280 Beam 4 5 6 7 8 9 10 11
281 Part I[4] I[5] I[6] I[7] I[8] I[9] I[10] I[11]
282 Distance from Pier Grid centre mm 1.4m 2m 5m 8m 11m 14m 17m Midspan
283 fck N/mm2 50 50 50 50 50 50 50 50
284 fcd =0.67/1.5 Fck N/mm2 22.33 22.33 22.33 22.33 22.33 22.33 22.33 22.33
285 fct N/mm2 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
286 fctd = fct/1.5 N/mm2 2.33 2.33 2.33 2.33 2.33 2.33 2.33 2.33
287 Interface Shear Design for Inner Webs
288 Calculate Effective width of Flange IRC 112 cl 7.6.1.2
289 bw web thickness mm 650 650 650 490 330 330 330 330
290 bi Left Refer Fig 9.1 of this document mm 1975 1975 1975 1975 1975 1975 1975 1975
291 bi Right mm 1645 1645 1645 1645 1645 1645 1645 1645
292 lo effective span for Simply Supported mm 38000 38000 38000 38000 38000 38000 38000 38000
293 beff left mm 1975 1975 1975 1975 1975 1975 1975 1975
294 beff Right mm 1645 1645 1645 1645 1645 1645 1645 1645
295
296 beff,total mm 4270 4270 4270 4110 3950 3950 3950 3950
297
298 Overal Depth of Slab Left mm 240 240 240 240 240 240 240 240
299 Overal Depth of Slab Right mm 240 240 240 240 240 240 240 240
300 Clear cover to Trans. Rlf. mm 35 35 35 35 35 35 35 35
301 Effective Depth of slab ..Assume 20mm Dia. Steel Left mm 195 195 195 195 195 195 195 195
302 Effective Depth of slab ..Assume 20mm Dia. Steel Right mm 195 195 195 195 195 195 195 195
303 Xu max = 0.456 d ..for Fe 500 Rlf. Steel Left mm 89 89 89 89 89 89 89 89
304 Xu max = 0.456 d ..for Fe 500 Rlf. Steel Right mm 89 89 89 89 89 89 89 89
305 `
311 hf Left hf mm 151 151 151 151 151 151 151 151
312 hf Right hf mm 151 151 151 151 151 151 151 151
313 Total Shear Force VED kN 11570 6578 4946 4042 5164 3773 2577 1099
314 Shear Force in Each inner Web
For Above and below values Ref:- Corresponding Longitudinal Design note - SC-960-S-A1-DN-
= (VED x (b (inner web)) / (b inner web + b outer strut)
315 5021
316 Shear Force in Each Inner Web VEd kN 1361 774 582 586 974 712 486 207
317 Shear Force in Ecah outer web due to Torsion kN 565 566 530 476 429 386 390 333
318 Total Shear Force per outer Web Vedf kN 1926 1339 1112 1062 1403 1098 876 540
319 IRC SP 105 section 8.3.4 Since there is a haunch on either sides of the web with a varying depth
320 v Ed = X . VEd . beff flange on one side And thus, the depth along the effective width is not constant
321 Z hf b total including web Instead of applying a reduction factor equal to the ratio of eff widths to total width
322 A reduction factor equal to the ratio of effective areas of flange has been applied
323 v Ed = X . VEd Aeff flange on one side
324 Z hf A total including web
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351

Page 36
SC-960-S-A1-DN-5021
STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0
DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN
352
353
354
355 Effective area ratio
356 Left Haunnch Dimensions a1 mm 240 240 240 240 240 240 240 240
357 b1 mm 240 240 240 240 240 240 240 240
358 l1 mm 500 500 500 500 500 500 500 500
359 A1 mm2 120000 120000 120000 120000 120000 120000 120000 120000
360 Effective area to left of web A1ef mm2 474000 474000 474000 474000 474000 474000 474000 474000
361 Right Haunnch Dimensions a2 mm 240 240 240 240 240 240 240 240
362 b2 mm 240 240 240 240 240 240 240 240
363 l2 mm 500 500 500 500 500 500 500 500
364 A2 mm2 120000 120000 120000 120000 120000 120000 120000 120000
365 A2ef mm2 394800 394800 394800 394800 394800 394800 394800 394800
366
367 Aweb mm2 156000 156000 156000 117600 79200 79200 79200 79200
368
369 ATotal mm2 1024800 1024800 1024800 986400 948000 948000 948000 948000
370 Z (Effective Depth) mm 2430 2430 2430 2430 1924 1924 1924 1924
371 vED(Left) IRC SP 105 section 8.3.4 N/mm2 1.71 0.98 0.73 0.77 1.68 1.22 0.84 0.36
372 vED(Right) v Ed = X . VEd . Aeff flange on one side N/mm2 1.43 0.81 0.61 0.64 1.40 1.02 0.70 0.30
373 Taking X = 1 Z hf A total including web
374
375 vRdmax θf = 45 IRC SP 105 Fig C 10.18 N/mm2 5.66 5.66 5.66 5.66 5.66 5.66 5.66 5.66
376
377 Hence whether vRdmax > vED(Left)/(Right) vED(Left) Left OK OK OK OK OK OK OK OK
378 vED(Right) Right OK OK OK OK OK OK OK OK
379
380 Is the Length of Flange under Compression Y/N Y Y Y Y Y Y Y Y
381 See Section 9.2 Row 31 Longi. Design Note

If Y, Min Strut Capacity θf = 26.50 vRdmin = 0.107fck(1-fck/310)


vRdmin 4.49 4.49 4.49 4.49 4.49 4.49 4.49 4.49
(N/mm2)
382
383 If N, Min Strut Capacity θf = 38.6 vRdmin = 0.130fck(1-fck/310) θfmin 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
384
VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin >
385 Check whether VRdmin > VEd Left
VEd VEd VEd VEd VEd VEd VEd VEd
VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin >
Right
386 VEd VEd VEd VEd VEd VEd VEd VEd
387
388 Hence for if VRdmin>VEd ,Take θf = 25.5 θf (Left) 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
389 or θf = 0.5 Sin-1(vEd/0.135fck(1-fck/310)) θf (Right) 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
390 IRC 112 Eq 10.23
391 Calculating Transverse Asf/sf = vEd x hf Left mm2/mm 0.297 0.169 0.127 0.133 0.290 0.212 0.145 0.062
392 Reinforcement fyd Cot θf Right mm2/mm 0.247 0.141 0.106 0.111 0.242 0.177 0.121 0.051
Provide Provide Transvers Transvers Provide Provide Transvers Transvers
Interface Interface e e Interface Interface e e
Check whether vEd < 0.4 fctd Shear Shear Reinforce Reinforce Shear Shear Reinforce Reinforce
Reinforce Reinforcem ment ment Reinforce Reinforce ment ment
393 ment ent Sufficient Sufficient ment ment Sufficient Sufficient
394

Page 37
SC-960-S-A1-DN-5021
STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0
DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN
Interface Shear Design- Soffit - Face of Web
280 Beam 4 5 6 7 8 9 10 11
281 Part I[4] I[5] I[6] I[7] I[8] I[9] I[10] I[11]
282 Distance from Pier Grid centre mm 1.4m 2m 5m 8m 11m 14m 17m Midspan
283 fck N/mm2 50 50 50 50 50 50 50 50
284 fcd =0.67/1.5 Fck N/mm2 22.33 22.33 22.33 22.33 22.33 22.33 22.33 22.33
285 fct N/mm2 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
286 fctd = fct/1.5 N/mm2 2.33 2.33 2.33 2.33 2.33 2.33 2.33 2.33
287 Interface Shear Design for Inner Webs
288 Calculate Effective width of Flange IRC 112 cl 7.6.1.2
289 bw web thickness mm 650 650 650 490 330 330 330 330
290 bi Left Refer Fig 9.1 of this document mm 0 0 0 0 0 0 0 0
291 bi Right mm 1715 1715 1715 1875 2035 2035 2035 2035
292 lo effective span for Simply Supported mm 38000 38000 38000 38000 38000 38000 38000 38000
293 beff left mm 0 0 0 0 0 0 0 0
294 beff Right mm 1715 1715 1715 1875 2035 2035 2035 2035
295
296 beff,total mm 2365 2365 2365 2365 2365 2365 2365 2365
297
298 Overal Depth of Slab Left mm 0 0 0 0 0 0 0 0
299 Overal Depth of Slab Right mm 700 700 675 675 675 675 675 675
300 Clear cover to Trans. Rlf. mm 35 35 35 35 35 35 35 35
301 Effective Depth of slab ..Assume 20mm Dia. Steel Left mm -45 -45 -45 -45 -45 -45 -45 -45
302 Effective Depth of slab ..Assume 20mm Dia. Steel Right mm 655 655 630 630 630 630 630 630
303 Xu max = 0.456 d ..for Fe 500 Rlf. Steel Left mm -21 -21 -21 -21 -21 -21 -21 -21
304 Xu max = 0.456 d ..for Fe 500 Rlf. Steel Right mm 299 299 287 287 287 287 287 287
305 `
311 hf Left hf mm 0 0 0 0 0 0 0 0
312 hf Right hf mm 401 401 388 388 388 388 388 388
313
314 Total Shear Force VED kN 11570 6578 4946 4042 5164 3773 2577 1099
315 Shear Force in Each inner Web For Above values Ref:- Corresponding Longitudinal Design note - SC-960-S-A1-DN-5021
= (VED x (b (inner web)) / (b inner web + b outer strut)
316
317 Shear Force in Each Inner Web VEd kN 5785 3289 2473 2021 2582 1887 1288 550

IRC SP 105 section 8.3.4 Since there is a haunch on either sides of the web with a varying depth
v Ed = X . VEd . beff flange on one side And thus, the depth along the effective width is not constant
Z hf b total including web Instead of applying a reduction factor equal to the ratio of eff widths to total width
A reduction factor equal to the ratio of effective areas of flange has been applied
v Ed = X . VEd Aeff flange on one side
Z hf A total including web

Page 36
SC-960-S-A1-DN-5021
STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0
DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN

Effective area ratio


Left Haunnch Dimensions a1 mm 0 0 0 0 0 0 0 0
b1 mm 0 0 0 0 0 0 0 0
l1 mm 0 0 0 0 0 0 0 0
A1 mm2 0 0 0 0 0 0 0 0
Effective area to left of web A1ef mm2 0 0 0 0 0 0 0 0
Right Haunnch Dimensions a2 mm 700 700 275 275 275 275 275 275
b2 mm 700 700 675 675 675 675 675 675
l2 mm 815 815 450 450 450 450 450 450
A2 mm2 570500 570500 213750 213750 213750 213750 213750 213750
A2ef mm2 786500 786500 517350 555750 594150 594150 594150 594150

Aweb mm2 455000 455000 438750 330750 222750 222750 222750 222750

ATotal mm2 1241500 1241500 956100 886500 816900 816900 816900 816900
318 Z (Effective Depth) mm 2430 2430 2430 2430 1924 1924 1924 1924
319 IRC SP 105 section 8.3.4
320 vED(Right) v Ed = X . VEd . Aeff flange on one side N/mm2 3.76 2.14 1.42 1.34 2.52 1.84 1.26 0.54
321 Taking X = 1 Z hf A total including web

322 vRdmax θf = 45 IRC SP 105 Fig C 10.18 N/mm2 5.66 5.66 5.66 5.66 5.66 5.66 5.66 5.66
323
324 Hence whether vRdmax > vED(Right)
325 vED(Right) Right OK OK OK OK OK OK OK OK
326
327 Is the Length of Flange under Compression Y/N Y Y Y Y Y Y Y Y
328 See Section 9.2 Row 31 Longi. Design Note

If Y, Min Strut Capacity θf = 26.50 vRdmin = 0.107fck(1-fck/310)


vRdmin 4.49 4.49 4.49 4.49 4.49 4.49 4.49 4.49
(N/mm2)
329
330 If N, Min Strut Capacity θf = 38.6 vRdmin = 0.130fck(1-fck/310) θfmin 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
331
332 Check whether VRdmin > VEd
VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin >
Right
333 VEd VEd VEd VEd VEd VEd VEd VEd
334
335 Hence for if VRdmin>VEd ,Take θf = 25.5
336 or θf = 0.5 Sin-1(vEd/0.135fck(1-fck/310)) θf (Right) 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
337 IRC 112 Eq 10.23
338 Calculating Transverse Asf/sf = vEd x hf
339 Reinforcement fyd Cot θf Right mm2/mm 1.729 0.983 0.631 0.598 1.119 0.818 0.558 0.238
Provide Provide Provide Provide Provide Provide Provide Transvers
Interface Interface Interface Interface Interface Interface Interface e
Check whether vEd < 0.4 fctd Shear Shear Shear Shear Shear Shear Shear Reinforce
Reinforce Reinforcem Reinforce Reinforce Reinforce Reinforce Reinforce ment
340 ment ent ment ment ment ment ment Sufficient
341

Page 37
SC-960-S-A1-DN-5021
STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0
DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN
Interface Shear Design- Soffit - End of Haunch
280 Beam 4 5 6 7 8 9 10 11
281 Part I[4] I[5] I[6] I[7] I[8] I[9] I[10] I[11]
282 Distance from Pier Grid centre mm 1.4m 2m 5m 8m 11m 14m 17m Midspan
283 fck N/mm2 50 50 50 50 50 50 50 50
284 fcd =0.67/1.5 Fck N/mm2 22.33 22.33 22.33 22.33 22.33 22.33 22.33 22.33
285 fct N/mm2 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
286 fctd = fct/1.5 N/mm2 2.33 2.33 2.33 2.33 2.33 2.33 2.33 2.33
287 Interface Shear Design for Inner Webs
288 Calculate Effective width of Flange IRC 112 cl 7.6.1.2
289 bw web thickness mm 650 650 650 490 330 330 330 330
290 bi Left Refer Fig 9.1 of this document mm 0 0 0 0 0 0 0 0
291 bi Right mm 1715 1715 1715 1875 2035 2035 2035 2035
292 lo effective span for Simply Supported mm 38000 38000 38000 38000 38000 38000 38000 38000
293 beff left mm 0 0 0 0 0 0 0 0
294 beff Right mm 1715 1715 1715 1875 2035 2035 2035 2035
295
296 beff,total mm 2365 2365 2365 2365 2365 2365 2365 2365
297
298 Overal Depth of Slab Left mm 0 0 0 0 0 0 0 0
299 Overal Depth of Slab Right mm 700 700 275 275 275 275 275 275
300 Clear cover to Trans. Rlf. mm 35 35 35 35 35 35 35 35
301 Effective Depth of slab ..Assume 20mm Dia. Steel Left mm -45 -45 -45 -45 -45 -45 -45 -45
302 Effective Depth of slab ..Assume 20mm Dia. Steel Right mm 655 655 230 230 230 230 230 230
303 Xu max = 0.456 d ..for Fe 500 Rlf. Steel Left mm -21 -21 -21 -21 -21 -21 -21 -21
304 Xu max = 0.456 d ..for Fe 500 Rlf. Steel Right mm 299 299 105 105 105 105 105 105
305 `
311 hf Left hf mm 0 0 0 0 0 0 0 0
312 hf Right hf mm 401 401 170 170 170 170 170 170
313
314 Total Shear Force VED kN 11570 6578 4946 4042 5164 3773 2577 1099
315 Shear Force in Each inner Web For Above values Ref:- Corresponding Longitudinal Design note - SC-960-S-A1-DN-5021
= (VED x (b (inner web)) / (b inner web + b outer strut)
316
317 Shear Force in Each Inner Web VEd kN 5785 3289 2473 2021 2582 1887 1288 550

IRC SP 105 section 8.3.4 Since there is a haunch on either sides of the web with a varying depth
v Ed = X . VEd . beff flange on one side And thus, the depth along the effective width is not constant
Z hf b total including web Instead of applying a reduction factor equal to the ratio of eff widths to total width
A reduction factor equal to the ratio of effective areas of flange has been applied
v Ed = X . VEd Aeff flange on one side
Z hf A total including web

Page 36
SC-960-S-A1-DN-5021
STRUCTCON DESIGNS PVT. LTD. 22-Apr-20 R0
DESIGNED KVC
PROJECT : DWARKA EXPRESSWAY - PACKAGE -II
REVIEWED AAY
LONGITUDINAL ANALYSIS AND DESIGN OF 16 M WIDE SUPERSTRUCTURE FOR TYPICAL APPROVED ASK
SUBJECT :
STRAIGHT 40M SPAN

Effective area ratio


Left Haunnch Dimensions a1 mm 0 0 0 0 0 0 0 0
b1 mm 0 0 0 0 0 0 0 0
l1 mm 0 0 0 0 0 0 0 0
A1 mm2 0 0 0 0 0 0 0 0
Effective area to left of web A1ef mm2 0 0 0 0 0 0 0 0
Right Haunnch Dimensions a2 mm 700 700 275 275 275 275 275 275
b2 mm 700 700 675 675 675 675 675 675
l2 mm 815 815 450 450 450 450 450 450
A2 mm2 570500 570500 213750 213750 213750 213750 213750 213750
A2ef mm2 216000 216000 303600 342000 380400 380400 380400 380400

Aweb mm2 455000 455000 438750 330750 222750 222750 222750 222750

ATotal mm2 1241500 1241500 956100 886500 816900 816900 816900 816900
318 Z (Effective Depth) mm 2430 2430 2430 2430 1924 1924 1924 1924
319 IRC SP 105 section 8.3.4
320 vED(Right) v Ed = X . VEd . Aeff flange on one side N/mm2 1.03 0.59 1.90 1.89 3.67 2.68 1.83 0.78
321 Taking X = 1 Z hf A total including web

322 vRdmax θf = 45 IRC SP 105 Fig C 10.18 N/mm2 5.66 5.66 5.66 5.66 5.66 5.66 5.66 5.66
323
324 Hence whether vRdmax > vED(Right)
325 vED(Right) Right OK OK OK OK OK OK OK OK
326
327 Is the Length of Flange under Compression Y/N Y Y Y Y Y Y Y Y
328 See Section 9.2 Row 31 Longi. Design Note

If Y, Min Strut Capacity θf = 26.50 vRdmin = 0.107fck(1-fck/310)


vRdmin 4.49 4.49 4.49 4.49 4.49 4.49 4.49 4.49
(N/mm2)
329
330 If N, Min Strut Capacity θf = 38.6 vRdmin = 0.130fck(1-fck/310) θfmin 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
331
332 Check whether VRdmin > VEd
VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin > VRdmin >
Right
333 VEd VEd VEd VEd VEd VEd VEd VEd
334
335 Hence for if VRdmin>VEd ,Take θf = 25.5
336 or θf = 0.5 Sin-1(vEd/0.135fck(1-fck/310)) θf (Right) 26.5 26.5 26.5 26.5 26.5 26.5 26.5 26.5
337 IRC 112 Eq 10.23
338 Calculating Transverse Asf/sf = vEd x hf
339 Reinforcement fyd Cot θf Right mm2/mm 0.475 0.270 0.370 0.368 0.716 0.523 0.357 0.152
Provide Provide Provide Provide Provide Provide Transvers
Interface Transverse Interface Interface Interface Interface Interface e
Check whether vEd < 0.4 fctd Shear Reinforcem Shear Shear Shear Shear Shear Reinforce
Reinforce ent Reinforce Reinforce Reinforce Reinforce Reinforce ment
340 ment Sufficient ment ment ment ment ment Sufficient
341

Page 37

You might also like