You are on page 1of 1

FLG

A
-
PW1100G JM
SECONDARY AIRFLOW AND LUBRICATION SYSTEMS
Fan Exit
Fairing
and Support Customer Nacelle Start ACC
ECS Anti-ice Bleed Air Buffer Air
Heat Exchanger
FEGV

To Core Compartment

TIC/LPT Cooling Air 4 Pipes

3 Pipes FLG
FLG FLG
P
R S
FLG
HPT Cooling Air 4 Pipes
To
FES
Pressure Oil FLG
V No. 3 Bearing N1
To Bearing FLG
V2 V3
Compartments I S1 S2
Breather Air To Deoiler FLG N
1,1.5, 2 G FLG
EGV FLG M
H
V E V1
TIC

V V1 V2 FLG
S S S S S S S8
I 2 3 4 5 6 S7
Ti
G 1
V

No. 1 No. 1.5


Bearing Bearing
No. 4 Bearing No. 5 Bearing No. 6 Bearing
No. 2 Bearing No. 3 Bearing

R1 To Scavenge
R2 R R R R R R
Pump
3 4 5 6 7 8
T1 T2 STA
STA STA
4.5
2 2.5

STA STA T1
R1 R2 R3 3 T2
4 T3 STA
4.9

To Scavenge Pump STA


2.5 To 5
Bleed Air Overboard Scavenge
Breather Pump
To Bearing
Compartments
R1 To Scavenge Pump

To Scavenge Pump To Scavenge Pump SECONDARY AIR SOURCES LUBRICATION SYSTEM


Fan Air Pressure Oil
COMPRESSOR ROTORS (LPC) COMPRESSOR STATORS (LPC) TURBINE ROTORS (HPT) TURBINE STATORS (HPT)
LPC Discharge Air Breather Air
Stage Blades Stage Vanes Stage Blades Stage Vanes
R1 20 (Fan) 64
HPC 3rd Stage Air Scavenge Oil
FES T1 44 V1 32
FEGV 48 T2 44 V2 26
R1 31 VIGV 61 Cooled HPC 3rd Stage Buffer Air Combined Breather Air
R2 53 S1 65 and Scavenge Oil
R3 67 S2 63 HPC 6th Stage Air
EGV 81 Check Valve
STA
12 STA COMPRESSOR ROTORS (HPC) COMPRESSOR STATORS (HPC) TURBINE ROTORS (LPT) TURBINE STATORS (LPT)
HPC 7th Stage Air
14 Control Valve
Stage IBR Airfoils Stage Vanes Stage Blades Stage Vanes HPC 8th Stage (HPC Discharge) Air
R1 26 VIGV 39 T1 84 V1 (TIC) 16 Air Flow
R2 38 S1 46 T2 86 V2 60 HPC 6th & HPC 8th Stage Air
R3 52 S2 61 T3 78 V3 66 FLG Flange
R4 58 S3 78 HPC 7th & HPC 8th Stage Air
R5 68 S4 106 STA Station
R6 73 S5 120
R7 70 S6 140 LPC Discharge Air & HPC 3rd Stage Air
R8 66 (Blades) S7 130
S8 117 Flow Conditions Shown Are Representative Of Above Idle Engine Operation
WARNING - This document contains technical data the export of which is or may be restricted by the Export Administration Act PROPRIETARY STATEMENT:
and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. This document/product is the property of United Technologies Corporation (UTC). You may not
The export, reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, possess, use, copy or disclose this document/product or any information in it, for any purpose
or for any use or purpose other than that for which the technical data was originally provided by Pratt & Whitney, is prohibited including without limitation to design, manufacture, or repair parts, or obtain FAA or other government
CUSTOMER TRAINING without prior written approval from Pratt & Whitney and authorization under applicable export control laws. approval to do so, without UTC's express written permission. Neither receipt nor possession of this
document/product alone, from any source, constitutes such permission. Possession, use, copying or
EAR Export Classification: ECCN 9E991 disclosure by anyone without UTC's express written permission is not authorized and may result in
R
criminal and/or civil liability. The foregoing legend shall not apply if this document/product is delivered
FOR TRAINING PURPOSES ONLY C 2014 United Technologies Corporation, Pratt & Whitney - All Rights Reserved to the U.S. Government under an applicable and conflicting contract clause or regulation. PW1100G-JM-AF Aug 2014

You might also like