APPENDIX 15 (Informative) RING AND RADIAL FINAL CIRCUIT ARRANGEMENTS, REGULATION 433.1 This appendix sets out options for the design of ring and radial final/¢ireuits for household and similar premises in accordance with Regulation 433.1, using socket-outlets and fused connection units. It does not cover other aspects, of the design of a circuit such as: 2 is 3 — Protection against electric shock, Chapter 41“ 30 al Ving 3s Pbk — Protection against thermal effects, Chapter 42 = — Protection against overcurrent, Chapter 43. Piast Bole Est Selection and erection of equipment, Part 5. ~~ fem toch Fig 15A - Ring final circuit arrangements, Regulation 433.1.204 ‘The load current in any part ofthe circuit should be unlikely to exceed for long periods the current-carrying capacity of the cable (Regulation 433.1.204 refers). This can generally be achieved by: (locating socket-outlets to provide reasonable sharing of the load around the ring Gi) not supplying immersion heaters, comprehensive electric space heating or loads of a similar profile from the ringcireuit On dedicated ev uit Gi) connecting cookers, ovens and hobs with arated power exceeding 2 KW on their own dedicated radial cireuit (iv) taking account of the total floor area being served. (Historically, a limit of 100 m* has been adopted.) 1076 spf “Aangiral oat state sr trshes a the cstrbuton board Toe Aara2A vercurart protect “lice NOTE: Consisrs reed for easton frien ban RC UUntused spur fon att 33 Aunts spur shoul to on6 ‘singlerenetwnsocketouier | $22.6.202 anc 200, ony ‘rvnfases spurmay be H onnnte ov gone ye. iain the dation boa . NoT Recommended | spur using an FCU not connected dircty tothe ring || Spur using an FCU connected directly to Tha nurse of socket outels supoted fom 8 fed The numberof seks outs suppina om 8 | Comecton unis eependnt upon tne o8d connection unt is dependent uoen Reload | shitocoriten ving ton der ino accourt Skaractermbes, navng akon very to account. ‘Gables shoul, wherever practicable be fveain a poston such tat oy wi a] Be covered by thermal nmsatin, Where # eae party of copltey Covered by armel nation, eletence shou be ae te Regain 23.9. Not recommardod Fused connection unit (FCU) supplying fixed equipment (Fresenionent Fused connection unit (FCU) to BS 1963-4 Maximum fuse 19, + | | @uunetion box 0 8S EN 60670-22 Joe | | Junction boxes with screw trminals must bo ‘accessible for inspection, testing & maintenance 2_| | or ateratvely, use mainonance-fee termina! Connections (Regulation 526.3), NOTE: Conductor size relates to 8S 6006 “Tat twin & earth cable ard the minimum cross-sectional area for the ve ‘conductors only Le. LN, Reduced crcuit protective conductor size is pormttd we. ‘Smmé, CPC = 3.5mm ‘Smm2 CPC = 10mm 505

You might also like