You are on page 1of 70

EN

DomoFlex 2 ®
Electric screw driven platform lift
sample image

INSTALLATION AND COMMISSIONING


INSTRUCTIONS
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

20220116

0 First edition 16.01.2022


Rev. Description Date

2 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


TABLE OF CONTENTS
1. Manual reading guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.01. Preliminary information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.02. Personal security and risk recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. Safety and information Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.01. DANGER Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.02. PROHIBITION Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.03. MANDATORY Signs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.04. Information symbols and infographics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3. Liability and warranty conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4. General requirements and installation site management . . . . . . . . . . . . . . . . . . . . . 9
4.01. General requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5. Box content - screws kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6. Tools required for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7. Preliminary checks and shaft preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
8. Electrical system preliminary checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
8.01. Electrical system before the platform - Preparing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
9. Guide rails, upper beam and transoms - installation . . . . . . . . . . . . . . . . . . . . . . . . 17
9.01. Guide rails - fixing to the template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
9.02. Rear corner profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
9.03. Transoms - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
9.04. Guide rails - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
9.05. Headroom beam and transoms - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
9.06. Headroom beam - wall mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
9.07. Shell - plumb / wall anchoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
10. Mechanics, pit bottom accessories - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
10.01. Geared motor - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
10.02. Pit stop - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
10.03. Safe Pit - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
10.04. Manoeuvring screw - pre-assembly and installation . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10.05. Platform backboard (with mechanics) - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
10.06. Flat cables - installation and connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
10.07. Safety contact in the headroom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
10.08. Magnet support brackets - contacts - ramps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
10.09. Electric connections for first start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
10.09.01 Shaft electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10.09.02 Electrical connections of the doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
10.10. Before operating the platform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
10.11. Platform floor - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

IM.TEC.125.EN_rev.0 | 3 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10.12. Proximity edge - connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42


10.13. Infills (doors and panels) - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
10.13.01 Front corner profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
10.13.02 Landing door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
10.13.03 Infill under landing door (other than ground landing door) . . . . . . . . . . . . . . . . . . . . . . . . 48
10.13.04 Safe pit - control lever connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
10.13.05 Infill installation (lateral and behind the mechanics) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
10.14. Roof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
11. First test travel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
12. Last installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
12.01. Wiring cover profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
12.02. Mechanical protection panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
12.03. Front panel and handrails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
12.04. Anchoring ties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
12.05. OPEN version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
13. Safety signs to be applied on the platform lift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
14. Final checks and adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
15. Platform noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

4 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


1. Manual reading guide
NOTICE
EN: Translation of the original instructions
This product may only be commissioned if these instructions are available to you in an official
EU language that you understand and you have understood the contents. If this is not the
case, please contact your Lifting Italia S.r.l. contact partner.

READ THIS MANUAL CAREFULLY


BEFORE INSTALLING AND USING THE PRODUCT
Retain the technical documentation near the lifting platform for the entire lifecycle of the product. In case of
change of ownership, the technical documentation must be provided to the new user as an integral part of the
product.

1.01. Preliminary information

NOTICE
This product must be installed and put into operation according to the provisions and regulations
in force. Improper installation or improper use of the product can cause damage to people and
property, as well as cause the warranty to lapse.

FOLLOW THE SUGGESTIONS AND RECOMMENDATIONS TO OPERATE IN SAFETY.


Any unauthorized modification can compromise the safety of the system, as well as the correct operation
and the life of the machine. If you have any doubts regarding the correct understanding of the information
and contents contained in this manual, contact LIFTING ITALIA S.r.l. immediately.
QUALIFIED PERSONNEL.
The product covered by this documentation can only be installed by qualified personnel, in
compliance with the attached technical documentation, above all in compliance with the safety
warnings and the precautions contained therein.

IM.TEC.125.EN_rev.0 | 5 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

1.02. Personal security and risk recognition

This manual contains safety rules that must be observed to safeguard personal safety
and to prevent damage to the property.

The indications to be followed to guarantee personal safety are highlighted by a triangle symbol while those to
avoid material damage are not preceded by the triangle. The hazard warnings are shown as follows and indicate
the different levels of risk in descending order.

RISK CLASSIFICATION AND RELATIVE GRAVITY OF DAMAGE


The symbol indicates that the failure to comply with appropriate safety
DANGER measures causes death or serious physical injury.
The symbol indicates that the failure to observe the corresponding safety
WARNING

RISK LEVEL
measures can cause death or serious personal injury.
The symbol indicates that failure to observe the relevant safety measures
CAUTION can cause minor or moderate personal injury or damage to the device.
It is not a symbol of security. It indicates that the failure to comply with
NOTICE relevant safety measures can result in property damage.
If there are multiple levels of risk, the danger warning always indicates the highest one. If a warning is drawn with
a triangle to warn to the risk of injury to persons, the risk of possible property damage may also be caused at the
same time.

WARNING
During installation / maintenance of the platform, the safety functions are temporarily suspended.
Therefore all necessary precautions must be taken to avoid personal injury and / or damage to the
product.

6 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


2. Safety and information Signs
2.01. DANGER Signs

DANGER FLAMMABLE
GENERAL DANGER ELECTRICITY DANGER
MATERIAL

DANGER OF FALL BY A DANGER SUSPENDED


DANGER OF CRUSHING
LEVEL LOADS

2.02. PROHIBITION Signs

PROHIBITED TO WALK ON
GENERIC PROHIBITION FORBIDDEN TO STEP ON
OR STOP IN THIS AREA

2.03. MANDATORY Signs

OBLIGATIORY TO WEAR THE OBLIGATORY TO WEAR OBLIGATORY WEAR THE


PROTECTION HELMET SAFETY SHOES PROTECTIVE GLOVES

OBLIGATORY TO WEAR EYE OBLIGATION TO WEAR THE


PROTECTION AUDIO PROTECTION

2.04. Information symbols and infographics

DRILL +
CARPENTER’S PENCIL CORNER GRINDER
ELECTRIC SCREWDRIVER

CORDLESS BLIND RIVET VACUUM LIFTER WITH


STEEL TAPE MEASURE
GUN MANOMETER

HAMMER

INFORMATION
Symbol that identifies information that is useful to the installer but is not mandatory for the
installation, nor does it pose a risk to the user..
ELECTRICAL CONNECTIONS
Symbol that identifies the connection of an electrical component.
For connection, refer to the electrical diagram and to the Manual IM.TEC.129 "ELECTRICAL
EQUIPMENT (U.D.E.C.) INSTALLATION AND DIAGNOSTICS".

IM.TEC.125.EN_rev.0 | 7 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

3. Liability and warranty conditions


RESPONSIBILITY OF THE INSTALLER
NOTICE

Installers are responsible for ensuring compliance with safety procedures at work and any health and
safety regulations in force in the country and on the site where the assembly is carried out.

The elevator / platform is produced and intended to be installed as described in the attached project drawing
and in this manual; any divergence from the prescribed procedure may affect the operation and safety of the
system and cause the immediate cancellation of the warranty.
Any modification or variation made to the project and the to the assembly Instructions must be documented
in detail and referred to LIFTING ITALIA S.r.l., in order to allow the company an adequate assessment. Under no
circumstances can a modified system be activated without the express authorization of LIFTING ITALIA S.r.l.
The elevator / platform must only be used in the way envisaged by the system and illustrated in the relative
manuals (transportation of people and / or things, maximum loads, cycles of use, etc.). LIFTING ITALIA S.r.l.
assumes no responsibility for damage to persons and property caused by improper use of the system.

Pictures and images on this manual are for illustration purposes only.

8 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


4. General requirements and installation site management
4.01. General requirements

CAUTION
For more information on safety, liability and warranty conditions, receipt and storage of material
on site, packaging, waste disposal, cleaning and storage of the product; refer to the “SAFETY
INSTRUCTIONS AND SITE MANAGEMENT” manual.

NOTICE
PRELIMINARY CHECKS.
Once the packaging has been opened, check that the product is intact and has not been damaged
during transport. Should any anomalies or damage be found, please dispatch them in writing on the
transport document to the transport company, giving written notice to LIFTINGITALIA S.r.l.

WARNING
SAFETY AND SITE MANAGEMENT - OVERALL DISPOSITIONS:
1. Always secure tools and any objects against falling;
2. Pay the utmost attention to all the steps described in this;
3. While assembling the parts making up the system or after installation, be careful of any sharp burrs
(machining residues).

• Before proceeding with the installation, it is necessary to remove any rubble and material
deposited during the construction of the shaft.

• Only nuts and bolts included in the supply must be used.

• The bags containing the screws must be opened in correspondence with the respective operating
phases indicated in this manual.

• The instructions described in this manual refer to a reinforced shaft, to a fastening with
mechanical expansion plugs of the stud type. For the use of plugs in masonry other than the
reinforced concrete see the attachment to this manual. For the shafts with metal framework, we
proceed by replacing the plugs with normal screws.

• In these instructions and on the wiring diagram, the stops are indicated with 0, 1, (2, 3 etc.),
meaning “0” the lowest stop: the numbers on the push-button panels may be different according
to the user’s needs (for example - 1, 0, etc.)..

If the load is greater than 50kg,


2x use the hoist for handling.
MAXIMUM
The assembly must be LOAD LIMIT
50 kg > 50 kg
performed by a
MINIMUM 2 people

IM.TEC.125.EN_rev.0 | 9 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

5. Box content - screws kit


Each box with its identification code represents how many pieces per item are contained in each
package (KIT).

F353.23.0001 F353.23.0002

10 x M12x125 4x M5x12 4x Ø5 4x Ø5
4x M8x30 4x Ø8 4x Ø8

2x M6x20

F353.23.0003 F353.23.0004

1x 6x6x30
1x
36 x M8x30 52 x M8x20 32 x M4x16
68 x M5x30

1x 1x 8x M6x13

F353.23.0005 F353.23.0006

2x M10x30 8 x M4x20 2x
400 x M4x10
18 x M8x20
80 x M4.8x11

F353.23.0007 20 x Ø8 4x Ø4 2x

4x M5x12 4x Ø5 4x Ø5

2x 2x 2x

1x 1x 2x 4x 12 x 2x

10 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


F353.23.0008 F353.23.0009

1x M6x16 8x M8x30 12 x M8x30


1 x M8x50 6x M12x125
1 x M8x70 6x

1x 1x 1x
4x Ø12-Ø36 10 x M12

1x

F353.23.0010 D003.23.0001

2x M8x90

2x M6x20 2x M8x10 2x
12 x M6x13 2x M4x12 2x

NOTICE
For threaded fixings coupling, please respect the below table.
All the screws used for the lift assembly, have been tightened using the parameters stated in the
below table.

SCREW COUPLE MAX (Nm) COUPLE MIN (Nm)


M3 1.2 1.0
M4 2.6 2.1
M5 5.1 4.1
M6 9.0 7.0
M8 21.0 17.0
M10 42.0 34.0
M12 71.0 57.0
M16 175.0 145.0

In case of necessity, consult the table.

IM.TEC.125.EN_rev.0 | 11 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

6. Tools required for installation


BALL POINT LONG HEX ELECTRICIAN HAMMER +
TAPE MEASURE
KEY WRENCH SCREWDRIVER SET RUBBER HAMMER

SCISSORS FOR SPANNER + RACKETING RING


SPIRIT LEVEL
ELETTRICIANS SOCKET WRENCH SPANNER SET

5÷27 mm

SAFETY LADDER
PLIERS WRENCH PORTABLE LAMP LIFTING BELTS
5 STEPS

kg
500
≥2m

DRILL + CUT-OFF AND GRINDING


DRILL BITS CORNER GRINDER
ELECTRIC SCREWDRIVER WHEELS

CONCRETE STEEL
from 6 to 22 mm from 2 to 13 mm

12 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


VACUUM LIFTER WITH INSULATING TAPE +
MANOMETER
MANUAL HOIST PLUMB BOB
DOUBLE-SIDED ADHESIVE

kg
kg 500
100 ≥ 15 m

DIGITAL MULTIMETER LASER LEVEL CORDLESS RIVETER GUN HSS STEP DRILL BIT

IM.TEC.125.EN_rev.0 | 13 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

7. Preliminary checks and shaft preparation


WARNING
The checks can only be carried out by direct
confirmation with the final design drawing of the C
machine (GAD) in its latest approved revision.

• Check the vertical free dimensions along the entire shaft, in


vertical projection of the pit, as indicated on the GAD.
• Check that the dimensions of the pit, storey heights and
headroom are the same as those specified in the GAD.

CAUTION
B
The GAD indicates the permissible deviation
tolerances from the nominal dimensions.

A = PIT
B = STOP
C = HEADROOM
A

• Check that the shell/guide rails fixings can be realized at the


points specified in the GAD, by direct fixing to a load-bearing
wall or tie.

WARNING
The distance between the fixing points cannot for
any reason exceed the dimensions indicated in the L4
GAD.

L3

L2

L1

14 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


• Carefully level the pit bottom template (+/- 2 mm) with the shims provided, checking the position with the
plumb bob in relation to the vertical of the shaft.

We recommend using the laser level to


help you level the template correctly.

• Secure the template to the floor ONLY FROM THE


MECHANICS SIDE, through the prearranged holes.

M12x125
Ø 12
F353.23.0001

IM.TEC.125.EN_rev.0 | 15 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

8. Electrical system preliminary checks


8.01. Electrical system before the platform - Preparing
• The client must guarantee the protections suitable for the electrical power distribution system and the relative
short-circuit current for the Power Supply Panel, according to standard CEI 64-8 et seq. (thermal-magnetic
circuit breaker of adequate size and 30mA differential protection).
• The main disconnecting switch for the motor power, also supplied by LiftingItalia, is installed inside the platform
control panel. .

After installing the power supply panel, record it has been checked in accordance with point 4.01.01 of the manual
“IM.TEC.127 - DOMOFLEX-2 - Final Checks”.

220/230 V AC - 50/60 Hz

QF1

Features:

A 20A curve C + F/B

B L N PE

POWER CONTROL PANEL


LIFTINGITALIA

Legend:
A general electrical panel of the building
B POWER CONTROL PANEL LIFTINGITALIA

WARNING

RISK OF ELECTROCUTION:
The lighting and power supply systems must meet the requirements of the system and the
regulations in force. Check that it has an effective earth. If they do not meet all the requirements,
interrupt the installation until the system has been brought up to standard by the customer.

16 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


9. Guide rails, upper beam and transoms - installation
CAUTION
READ FOR PROPER INSTALLATION
Proper installation of guide rails, screw, and platform requires accuracy and patience.
Adjustments and alignments on the machine can only be performed at the installation site.
The time spent on these adjustments allows a smooth, quiet, vibration-free travel.
The longer the travel, the more care must be taken when adjusting.
Follow all the instructions included in this manual.
In particular, it is recommended to carefully check the alignment of guide rails,
screws, pins, and platform shoes, and the lubrication of screw and guide rails.

9.01. Guide rails - fixing to the template


• Position the guide rails so that the holes match those on the
M6x13
start template and secure them with the screws provided.
F353.23.0004

IM.TEC.125.EN_rev.0 | 17 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

9.02. Rear corner profiles


• Position the outer corners, as shown in the diagram,
respecting the measurements provided in the design
drawing.

• Mark and drill the holes, performing:


- the FIRST HOLE 100 mm from the bearing surface;
- keeping a 180 mm centre-to-centre distance between the holes.

Near the guide rail joint, rivet 100 mm


above and below the joint.

• Secure the corner profiles from the inside, with the rivets
provided.

M4x10
F353.23.0005
180 mm
180 mm
100 mm

18 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


9.03. Transoms - installation

The transoms must be installed at the same time as the guide rail segments.

• Position the transom, open the tabs to facilitate correct


positioning;
• Secure the transom from the rear, using the screws provided.
M8x20
The transoms must be positioned inside F353.23.0004
the shell and secured from behind with the
screws provided.

CAUTION
Verify that the gauge measurements match
the design drawings.

• Fit the reinforcement brackets from inside the platform: drill


the guide rail and secure with the rivets provided.

M4x10
Ø4
F353.23.0005

• Continue with the combined installation of guide rails and


transoms, EXCEPT THE TRANSOM IN THE HEADROOM.

IM.TEC.125.EN_rev.0 | 19 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

• Drill the wall/slab at all anchor points indicated on the


design drawing.

WARNING Ø 12
Secure to the transom immediately below
the dimension indicated in the GAD.
Use the outermost holes for fixing. Only if
necessary, use alternative internal holes,
checking beforehand not to interfere with
the flexible cable mounting plate (see
paragraph "")

• Anchor the shell with the plugs provided. If necessary, use


shims on the rear to obtain correct vertical alignment.
M12x125
The anchoring illustrated here refers F353.23.0001
exclusively to the installation on a wall/slab
of compact, non-cracked concrete.

INFORMATION

In case the wall/slab to which the shell is to be anchored is not perfectly


vertical, it is necessary to use shims to obtain a perfect vertical alignment.
The shims shall be provided by the installer.

20 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


9.04. Guide rails - installation

WARNING
Take the guide rail top segments and remove
any aluminium burrs from the joining points.

WEAR APPROPRIATE PPE

• Insert the spring pins into the guide rail top segments only
for half their length, leaving them protruding half way out of M5x30
the profile.
F353.23.0004
It is recommended to secure the pins with
a drop of cyanoacrylic adhesive to ease the
installation of the guide rails.

• Insert the guide rail joining elements into the jamb housings.

IM.TEC.125.EN_rev.0 | 21 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

• Secure with the spring pins and screws provided.

M8x30 M4x16
F353.23.0004

• Insert the top segments and secure them with the screws
provided.

M8x30 M4x16
F353.23.0004

22 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


9.05. Headroom beam and transoms - installation
• Position the headroom beam in the position indicated by the
holes, using a hoist, and secure it to the guide rails using pre-
assembled screws.

To ease the handling of the


headroom beam, it is recommended
the use of a hoist.

M8x30

F353.23.0008

IM.TEC.125.EN_rev.0 | 23 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

9.06. Headroom beam - wall mounting


• Position the wall anchor brackets above the headroom
beam.

• Drill the wall at a position corresponding to the


holes in the brackets. M12x125
• Anchor the brackets with the plugs provided. Ø 12
F353.23.0001

• Drill the headroom beam at a position


corresponding to the holes in the brackets.
• Secure the brackets to the beam with the rivets M5x10
provided. Ø4
F353.23.0005

• Proceed with the installation of the last transom in the


headroom as previously seen.

24 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


9.07. Shell - plumb / wall anchoring
• Check the horizontal and vertical position of the installed
guide rails so that they are plumb (in both directions), with a
maximum deviation of +/- 2mm at each point.

IM.TEC.125.EN_rev.0 | 25 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10. Mechanics, pit bottom accessories - installation


10.01. Geared motor - installation
• Position and secure the geared motor with its
support on the template with the screws provided.

M8x30 Ø8 Ø8
F353.23.0002

• Position the geared motor protection plate and


secure it to the template, using the screws provided.

M5x12 Ø5 Ø5
F353.23.0002

10.02. Pit stop - installation


• Position the pit stop and secure it to the template
with the screws pre-mounted on the component.

M5x12 Ø5 Ø5
F353.23.0002

26 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


10.03. Safe Pit - installation

CAUTION

Install the Safe Pit safety device to ensure safe operation in the pit.

• Place the Safe Pit on the template at the bottom of the


pit: the strut must rest on the template and fit into the
prearranged pin.
• Secure the Safe Pit using the rivets provided.

M4x10
F353.23.0005

DANGER

The strut must be opened/closed manually


until the door, containing the control lever, is
installed.

CLOSED (OFF) SAFE PIT OPEN (ON) SAFE PIT

IM.TEC.125.EN_rev.0 | 27 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

The control lever for Safe Pit remote activation/deactivation


is pre-mounted in the cabinet of the electrical panel located
in the door jamb.
To connect it to the device, see Paragraph "".

28 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


10.04. Manoeuvring screw - pre-assembly and installation
• IN PIT: insert the screw support bush into the geared motor.

• Assemble the screw segments.


Use a suitable lifting device to lift the segments.

CHECK the design drawing for the length


of the individual segments and the correct
installation sequence. V3
The installation of the manoeuvring screws
must be performed from the bottom
upwards:
V1 > V2 > V3.

NOTE: The V2 segment is not always


present.

V2
M8x30

F353.23.0008

kg
500
≥ 15 m
V1

IM.TEC.125.EN_rev.0 | 29 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

WARNING

CAUTION WEAR APPROPRIATE PPE


CRUSHING HAZARD
Lift the screw segments using suitable lifting
equipment and always wearing the appropriate
PPE.
• Insert the assembled screw into the headroom beam.

• ON THE HEADROOM BEAM: position bush, bearing, and nut


screw on the screw.
• Screw in the screw so that it protrudes from the headroom
beam by approximately 1m.

≈1m

30 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


10.05. Platform backboard (with mechanics) - installation

CAUTION WEAR APPROPRIATE PPE


CRUSHING HAZARD
Lift the components using suitable lifting
equipment and always wearing appropriate
PPE.

CAUTION
Position and levelling adjustment of the platform is very important: incorrect
adjustment of the position and the shoes causes noises and vibrations

The car backboard is supplied pre-assembled.

• Remove the handrail and the front panel by unscrewing the


handrail locking pins.

• Install the bottom shoes onto the specific brackets.

M8x20
F353.23.0006

IM.TEC.125.EN_rev.0 | 31 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

• Position the platform backboard in the pit, inserting it into


the specific discharges provided on the guide rails, keeping it
raised with 2 risers (e.g. wooden blocks).

CAUTION
The height of blocks on which the platform
backboard rests must be AT LEAST 50 mm and
MAXIMUM 100 mm in order to be able to easily
insert the backboard into its housing.

kg
500
≥ 15 m

• Install the top shoes onto the specific brackets.

M8x20
F353.23.0006

• Check the vertical levelling of the platform backboard. If


necessary, adjust the levelling using the slots in the top
shoes.

32 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


• Secure the bottom and top shoes by drilling them at a position corresponding to the prearranged hole and
secure them with the pin to avoid movements of the same.

BOTTOM SHOES

M4x16 Ø4

F353.23.0004

TOP SHOES

M4x16 Ø4

F353.23.0004

• Secure the shoes by tightening the screws and install the


safety pins of the top shoes, on both sides.

F353.23.0006

IM.TEC.125.EN_rev.0 | 33 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

• Lower the manoeuvring screw until it is inserted into the pit


bush, passing through the motor of the mechanics assembly
(platform backboard).

• Secure the manoeuvring screw to the headroom nut screw


using the safety pin provided.

M8x70

F353.23.0008

• Secure the screw to the pit bush using the safety pin
provided.

M8x50

F353.23.0008

WARNING

34 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


10.06. Flat cables - installation and connection

The flat cable is pre-assembled on the platform


backboard. A

• Position the flat cable support bracket on the transom


positioned at a height equal to

travel
H >
2

with respect to the lowest access.


H 2X
B
F353.23.0007

• Unwind the flat cable starting from the platform wall and fix it to the flat cable support bracket A on the beam.
• Route the flat cable toward the pit template and secure it by positioning the brackets provided.
• Fix the flat cable to the beam every 2 m approximately with electrician cable ties as indicated in point B

CAUTION
Route the flat cable so that the folds are soft and
do not damage the cable. M5x12 Ø5 Ø5
F353.23.0007

IM.TEC.125.EN_rev.0 | 35 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10.07. Safety contact in the headroom


• Place the headroom safety contact on the
headroom beam.

M6x16
F353.23.0008

10.08. Magnet support brackets - contacts - ramps

Pay attention to the positioning of the magnet


support brackets:

IN THE HEADROOM, the bracket with the


overtravel contact must be positioned
facing down (bottom overtravel).

ALONG THE SHAFT, the brackets (if any) should be


placed WITHOUT the pre-assembled contact.

IN THE PIT, the bracket with the overtravel


contact must be positioned facing up (top
overtravel).

36 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


• Position the magnet support brackets so that the centre of the bracket (identified by the reference notch) is at a
distance of 840 mm from the floor level.
• Adjust the position of the magnets (IS, ID and IR) as shown in the figure: the magnet support plate is provided
with holes to ease magnet alignment.
840 mm
840 mm

Rall.
IS ID IR

≈ 10 mm

Rall.

The IR magnet is located on the lowest access only.

• Repeat the procedure for each access.

10.09. Electric connections for first start-up


The electrical panel is inside the lowest access landing door jamb.
The door must be already installed (even temporarily, following safety requirements) in order to
make the connections.

For electrical connections, refer to the manual IM.TEC.129 “ELECTRICAL EQUIPMENT (U.D.E.C.)
INSTALLATION AND DIAGNOSTIC INSTRUCTIONS” and to the system wiring diagram.

IM.TEC.125.EN_rev.0 | 37 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10.09.01 Shaft electrical connections

• wire the electrical components as they


are installed.

• The shaft electric line A must be the LAST


connection to the electrical panel.

WARNING
The electrical cables must be
routed into the compartment
prearranged in the guide rail. Once
the wiring is finished, the snap-on
guard can be installed.

CAUTION
The flat cables must be routed
in the through hole between the
guide rail and the door containing
the electrical panel, at the bottom
of the pit.

38 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


10.09.02 Electrical connections of the doors

UDEC.D

op�onal

op�onal

op�onal

IM.TEC.125.EN_rev.0 | 39 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10.10. Before operating the platform

WARNING
LUBRICATE ALL GUIDE RAILS WITH SILICONE SPRAY OIL SUPPLIED WITH THE SYSTEM (F353.05.9017).

LUBRICATE THE SCREW WITH THE SUPPLIED ENGINE OIL (F353.05.9018).

FILL THE LUBRICATOR WITH THE SUPPLIED ENGINE OIL (F353.05.9018).

WARNING

DURING THE FIRST OPERATION, CHECK THAT THE FLAT CABLE MOVES CORRECTLY.

40 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


10.11. Platform floor - installation

DANGER WEAR APPROPRIATE PPE


CRUSHING HAZARD
Lift the components using suitable lifting
equipment and always wearing appropriate
PPE.
• Lift the platform backboard along the screw and remove the
risers.
• Position the platform floor by resting it on the pit bottom.
• Lower the platform backboard until it touches the floor.

CAUTION
Adjust the position of the floor so that it is
equidistant from the edge of the shell.

• Secure the floor using the screws provided.

WARNING
The screws must be
SOCKET HEAD CAP SCREW M8x20 CLASS 12.9

Connect the proximity edge sensors located on


the floor, on the side opposite to the mechanics,
to the car board (UDEC.C)

M8x20 Ø8
F353.23.0006

IM.TEC.125.EN_rev.0 | 41 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10.12. Proximity edge - connection

DANGER

MANUALLY OPEN THE SAFE PIT STRUT FROM


OUTSIDE THE PIT.

CLOSED (OFF) SAFE PIT OPEN (ON) SAFE PIT

• Raise the platform so that there is room to operate and


secure the hook to the proximity edge, making sure the
sensor is working correctly.

F353.23.0006

42 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


10.13. Infills (doors and panels) - installation
The infills, the landing doors, and the guide rails (opposite to the mechanics), are installed in a
circular sequence from the bottom upwards.
The following will describe the individual operations; it is up to the installer to take the correct
reference for the installation of the components.

CAUTION

Protect the shoes from drilling chips.


CHECK THE CLEANLINESS OF THE SHOES AT EACH HOLE.

IM.TEC.125.EN_rev.0 | 43 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10.13.01 Front corner profiles

The front corner profiles must be installed after the side component (door or infill).
Follow the circular sequence as indicated at the beginning of the paragraph.

CAUTION

Secure the components as they are positioned.

• Position the outer corners, as shown in the diagram,


respecting the measurements provided in the design
drawing.

• Position the drilling template supplied with the system.

Position the template so that the holes


prearranged on the template match the
reference line on the corner profile.

• Mark on the infill (or door) side, and realize the prearranged
holes.

• Secure the corner profile with the rivets provided.

M4x10
Ø4
F353.23.0005

44 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


• Place the infill on the other side of the corner profile.
• Mark on the side of the newly positioned infill and realize
the prearranged holes.

• Secure the corner profile with the rivets provided.

M4x10
Ø4
F353.23.0005

Near the guide rail joint, rivet 100 mm above and below the joint.

Proceed from bottom to top.

IM.TEC.125.EN_rev.0 | 45 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10.13.02 Landing door

• position the door, inserting it into the prearranged seat on the rear corner profiles.

Check that the doors are correctly arranged as indicated on the design drawing.

FOR GROUND LANDING DOOR


Check that the ground landing door is resting on
the floor level.

46 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


• Drill the guide rails at a position corresponding to the holes
in the door and then secure the door using the screws
provided.

M6x13
Ø6
F353.23.0010

• Secure the other side of the door as indicated in


paragraph "10.13.01 Front corner profiles".

IM.TEC.125.EN_rev.0 | 47 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10.13.03 Infill under landing door (other than ground landing door)

FOR DOORS OTHER THAN GROUND LANDING DOOR


In case of doors other than the ground landing door, install the blanking panel under the door
BEFORE installing the floor door.

• Take a standard BLANKING infill panel and cut it to


size.

CAUTION
The infills UNDER THE DOORS SHOULD BE CUT AT THE INSTALLATION SITE.

TP

TP

WEAR APPROPRIATE PPE

• Using the bar as a template, mark the holes, perform


the drilling, and secure the infill panel with the rivets
provided.
M4x10
Ø4
F353.23.0005

20 mm

48 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


10.13.04 Safe pit - control lever connection

• raise the platform so that there is space to work; open the safety strut, connect the sheathed cable to the
control lever located inside the ground landing door jamb (containing the control panel) and to the pit strut.

IM.TEC.125.EN_rev.0 | 49 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10.13.05 Infill installation (lateral and behind the mechanics)

CAUTION
The base profiles must be positioned
before starting the installation of the infills.

• Place the base profiles into the specific housings.

The door side does not require the base


profile.

• Insert the infill panel into the specific guide rail


housing.

Proceed from bottom to top.

• If both panel containment guide rails are installed,


insert the infill as shown below.

50 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


• Secure the infill panel as indicated in paragraph
"10.13.01 Front corner profiles".

CAUTION
The BLANKING PANELS IN THE HEADROOM SHOULD BE CUT AT THE INSTALLATION SITE.

T6

T6

WEAR APPROPRIATE PPE

IM.TEC.125.EN_rev.0 | 51 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

10.14. Roof
• Insert the finishing profiles at the top to complete the
shell.
• Drill all 4 profiles from inside the shell and secure
them with the rivets provided.

M4x10
Ø4
F353.23.0005

• Position the roof support profiles on the sides of the


mechanics (one on the right and one on the left).
• Drill the infills at a position corresponding to the holes
prearranged on the profile and secure the profiles
with the rivets provided.

M4x10
Ø4
F353.23.0005

52 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


• Insert the covering panels (roof)

CAUTION
Check the sequence and direction of the panels for correct insertion.

P5
=
P4
= P3

P2
P1

P1 P2 P3 P4 P5

• Open the spotlight retaining springs


• Insert into the hole prearranged in the shell roof

Connect the spotlights to the electrical


panel (UDEC.M).
Refer to the wiring diagram.

IM.TEC.125.EN_rev.0 | 53 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

11. First test travel


Before performing the first test travel, make sure that all electrical components are connected
correctly.

WARNING
IT IS RECOMMENDED TO PERFORM A FULL TRAVEL WITH THE SLING IN
ADVANCE:
• thoroughly clean the guide rails and then oil them with suitable oil (e.g. ISO VG-220 EP or higher
grade);
• Visually check that there are no visible obstacles or protruding materials along the shaft that could
interfere with the sling and the basement.
• Check that all STOPS are disabled.
• Check that the safe pit device is disabled;
• Check that the distance between the car and the headroom is the same as that indicated by the
design.
• Power the controller by operating it in SERVICE mode.

WARNING
WITH THE SLING STATIONARY AT THE TOP FLOOR:
• Check that the sling upper travel margin on the guide rails corresponds to the design drawing.
• Adjust the position of the limit switch so that it trips after a lifting of approximately 30mm above
the floor.
• Lower the sling to the lowest floor.
• Pay close attention to the proper length of the flat cable and any interference during the travel.
• Adjust the position of the lower limit switch so that it trips after a downward travel of
approximately 30mm below the lowest access.
• Perform a few full travels, checking:
I. the movement of the flat cables;
II. any abnormal noise;
III. that the limit switches do not encounter obstacles.

54 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


12. Last installations
12.01. Wiring cover profile
• Install the wiring cover profile starting from the bottom of
the pit to the headroom from the bottom upwards.

CLICK

IM.TEC.125.EN_rev.0 | 55 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

12.02. Mechanical protection panels


• Insert the spring pins into the appropriate housings on the
pit floor template only for half their length, letting them
protrude by half their length from the profile and insert into
them the casing support guides.

It is recommended to secure the pins with


a drop of cyanoacrylic adhesive to ease the
installation of the guide rails.

M5x30

F353.23.0004

• Place the pins in the profile and insert the next guide rail.
• Drill the guide rail joint (pre-assembled in the bottom guide rail) at a
position corresponding to the prearranged holes.
• Assemble the guide rail segments and secure them with the screws
provided.

M5x30 M4x10
Ø4
F353.23.0004 F353.23.0005

56 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


• Position the brackets in the headroom and drill the
casing support guide and the mechanical guide.
• Assemble the brackets with the screws provided.

M4x10
Ø4
F353.23.0005

• Position the mechanical protection panels together


with the snap-on profiles on the casing support
guides.

CLICK

Check the correct positioning of the infills: the pit panel


(TF) can be distinguished from the others because it
is provided with a hole. This hole must be positioned
toward the bottom of the pit as it is used to access the
“PIT BOTTOM STOP” safety device. TF
Secure with glue the ring nut provided.

F353.23.0003

IM.TEC.125.EN_rev.0 | 57 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

• Position the transom over the pit panel with the


screws provided.

M6x20
F353.23.0002

• Proceed with the installation of all mechanical


protection panels with the snap-on profiles provided.

The infill IN THE HEADROOM SHOULD BE CUT AT THE INSTALLATION SITE.

TT

TT

WEAR APPROPRIATE PPE

58 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


12.03. Front panel and handrails

CAUTION WEAR APPROPRIATE PPE


CRUSHING HAZARD
Lift the components using suitable lifting
equipment and always wearing appropriate
PPE.

• Reposition the front panel and handrail, securing them with


the handrail locking pins.

IM.TEC.125.EN_rev.0 | 59 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

12.04. Anchoring ties

Refer to the PROJECT DRAWING to check the


position of the ties.

• Position the ties against the shell so that the brackets can
reach.
• Drill the wall at a position corresponding to the
holes in the brackets.
• Anchor the brackets with the plugs provided. If
necessary, use shims on the rear to obtain correct
vertical alignment.

M12x125
Ø 12
F353.23.0001

The anchoring illustrated here refers exclusively to the installation on a wall/slab of compact, non-
cracked concrete.

60 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


12.05. OPEN version
The "OPEN" version is characterized by an open
structure (without roof for closing the shaft)
lower than the standard model. At the top
landing floor, the platform is equipped with a
small gate (which replaces the landing door)
having the same height as the structure.

• Position the cover profiles so that they surround the infill


panels and the guide rails.

The shell closing profiles SHOULD BE CUT AT THE


INSTALLATION SITE.

WEAR APPROPRIATE PPE

• Place the fastening L piece in the corners opposite to


the mechanics.
M4x10
• Drill at a position corresponding to the prearranged Ø4
holes and assemble with the screws provided. F353.23.0005

IM.TEC.125.EN_rev.0 | 61 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

• Position the mechanical cover with the screw


protection plug.
• Drill at a position corresponding to the prearranged
M4x10
holes and assemble with the screws provided. Ø4
F353.23.0005

62 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


13. Safety signs to be applied on the platform lift
BUFFER SERIAL NUMBER

• AFTER LANDING DOOR CLOSURE ASSURE YOURSELF THAT IT IS PROPERLY

• BEFORE UNLOCKING THE LANDING DOOR ASSURE YOURSELF THAT THE LIFT
LOCKED

IS STANDING STILL AND THE CABIN IS ATTENDING AT THE FLOOR


LEFT
WHEN THE EMERGENCY MANOEUVRE

THE SHAFT
FALLING IN
DANGER OF

CASE OF EMERGENCY OPERATIONS.


USE IT TO UNLOCK LANDING DOORS ONLY IN

EMERGENCY KEY
BUFFER SERIAL NUMBER
UNAUTHORISED PERSONS
KEY IS PROHIBITED TO
THE USE OF EMERGENCY

RIGHT

PLATFORM
EMERGENCYDRIVING
KEY FORCE
RECOMMENDED
DRIVING FORCE

HYDRAULIC OIL
PLATFORM

Mineral oil ISO VG 46


USE IT TO UNLOCK LANDING DOORS ONLY IN SWITCH
SWITCH

Viscosity ≥ 100
CASE OF EMERGENCY OPERATIONS.
BEFORE REACHING TO THE
ACTIVATE THE OVERHEAD

Working temperature: + 5°C ÷ + 70°C


DANGER OF2)CRUSHING

Working temperature:

ID NUMBER
FORE UNLOCKING THE LANDING DOOR ASSURE YOURSELF THAT THE LIFT
Via Caduti del Lavoro, 16 - 43058 Bogolese, Sorbolo (PR) - ITALY
EMERGENCY DESCENDING

TANDING STILL AND THE CABIN IS ATTENDING AT THE FLOOR


ViscosityRIFERIMENTO
Mineral oilRESET
HYDRAULIC
RECOMMENDED

TER LANDING DOOR CLOSURE ASSURE YOURSELF THAT IT IS PROPERLY


ID NUMBER
PERSONS IS PROHIBITED
USE TO UNAUTHORISED

AREALIFT S.r.l. by LIFTINGITALIA S.r.l.

CKED
5) RUOTARE L’ALBERO

4) INNESTARE LA PARTE TERMINALE ESAGONALE DELL’ALBERO

3) APRIRE

1) ACCEDERE AL QUADRO DI MANOVRA;

4) AL TERMINE DELLA MANOVRA RIPRISTINARE LO STATO DEL QUADRO;

3) ATTIVARE LA MODALITÀ MANUTENZIONE

2) PROVARE A RIPRISTINARE IL FUNZIONAMENTO


1) ACCEDERE AL

ISTRUZIONI PER3)LACON
MOTORE CON

LATERALMENTE

MEDIANTE IL LUCCHETTO IN DOTAZIONE;


APRIRE IL SEZIONATORE QF-2 E BLOCCARLO IN POSIZIONE OFF

RAGGIUNGIMENTO DEL5)PIANO
CON I TASTI SALITA – DISCESA PRESENTI SUL TASTIERINO FINO AL

MANOVRA MANUALE MECCANICA.


FUNZIONAMENTO DEL QUADRO
NOTA: NEL CASO IN CUI3)NON
QUADRO
≥ 100

AREALIFT S.r.l. by LIFTINGITALIA S.r.l.


ER SERIAL NUMBER BUFFER SERIAL NUMBER
SAFETY

ISO VG
ROOF

Via Caduti del Lavoro, 16 - 43058 Bogolese, Sorbolo (PR) - ITALY

LEFT RIGHT
+ 5°C

O REALIZZANDO

DANGER OF CRUSHING
IL CARTER

DI MANOVRA;

▼ for inDOMO
DEVICE LATERALE DELLA GUIDA E ACCEDERE
EMERGENCY

46
MANOVRAFRENI

MANOVRA
OIL
UNA CHIAVE

÷ + 70°C MEDIANTE IL LUCCHETTO IN DOTAZIONE;


ALLO SCHEMA

QUADRO DI MANOVRA;
PERSONS IS PROHIBITED
USE TOMOTORE

AL MOTORE;

ACTIVATE THE OVERHEAD SAFETY DEVICE


UNAUTHORISEDIN SENSO ORARIO PER FAR SCENDERE

THE USE OF EMERGENCY


ASCENDING

DANGER OF
BEFORE REACHING TO THE ROOF
6) SE L’OPERAZIONE RISULTASSE DIFFICOLTOSA, APRIRE UNO DEI 2

4) INNESTARE LA PARTE TERMINALE ESAGONALE DELL’ALBERO

2) APRIRE
1)DEIACCEDERE

4) ALMANUALE

2) PROVARE A RIPRISTINARE IL FUNZIONAMENTO ESEGUENDO UN


1) ACCEDERE AL QUADRO DI MANOVRA;

FALLING IN KEY IS PROHIBITED TO


ISTRUZIONI PER LA DISCESA DI EMERGENZA
LA PEDANA;
RUOTARE
MOTORE CON UNA

LATERALMENTE
APRIRE

RAGGIUNGIMENTO DEL PIANO DI SBARCO;

ATTIVARE LA MODALITÀ MANUTENZIONE E MUOVERE LA MACCHINA


MANOVRA MANUALE MECCANICA.
FUNZIONAMENTO DEL QUADRO SEGUIRE LA PROCEDURE PER LA
NOTA: NEL CASO
QUADRO DI MANOVRA;
RIFERIMENTO ALLO SCHEMA ELETTRICO E ALLA DIAGNOSTICA DEL
RESET O REALIZZANDO DEI COLLEGAMENTI TEMPORANEI. FARE

UNAUTHORISED PERSONS
A CRICCHETTO O UN AVVITATORE CH. 13;

THE SHAFT
MANUALE

COLLEGAMENTI
FOSSE

EMERGENCY DESCENDING EMERGENCY ASCENDING


ELETTRICO

TERMINE DELLA

DISCESA
DI SBARCO;

I TASTI SALITA
SEGUIRE LAAL
DEL MOTORE

WHEN THE EMERGENCY MANOEUVRE


USE TO UNAUTHORISED USE TO UNAUTHORISED
IL POSSIBILE

IL SEZIONATORE

▼ for inDOMO Power ▼

PERSONS IS PROHIBITED PERSONS IS PROHIBITED


L’ALBERO MOTORE IN SENSO ORARIO PER FAR SCENDERE

CARTER LATERALE

HAS BEEN COMPLETED CLOSE AND


AL QUADRO
MANOVRA MANUALE MECCANICA

MANOVRA MANUALE ELETTRICA


Power

LOCK ALL LANDING DOORS PLATFORM ALARM


E ALLA DIAGNOSTICA
E MUOVERE
MECCANICA

ELETTRICA
DI

IN CUI NON
PROCEDURE

TEMPORANEI.
CHIAVE ALA

– DISCESA
CON L’APPOSITA LEVA MANUALE.

MANOVRA RIPRISTINARE LO STATO DEL QUADRO;


MOTORE; PER LA

ESEGUENDO
RIPRISTINARE

I0021.52.1003_rev.6
EMERGENZA

DANGER OF BRING THE PLATFORM AT THE LANDING LEVEL


DI MANOVRA;
QF-2 E BLOCCARLO

▼FOSSE POSSIBILE RIPRISTINARE IL ▼

FALLING IN
CRICCHETTO

DELLAILGUIDA E ACCEDERE
MACCHINA O UN AVVITATORE CH. 13;

PRESENTI SUL TASTIERINO FINO AL

IF IT IS NOT POSSIBLE, THE RECOVERY OPERATIONS OF THE PEOPLE MUST BE CARRIED OUT
FARE

THE SHAFT
UN

ONLY BY AUTHORIZED PERSONNEL


DEL IN POSIZIONE OFF

▼ for inDOMO Power ▼ ▼ for domoFLEX ▼


RECOMMENDED OIL CAUTION!
RUZIONI PER LASynthetic
DISCESA DI EMERGENZA INSTRUCTIONS FOR
PLATFORM MACHINERY

WITHOUT AUTHORIZATION

FOR BEARINGS AND GEARS PLATFORM MACHINERY


ENTRANCE FORBIDDEN

EMERGENCY OPERATION
oil ISO VG 220
Viscosity number ≥ 195
MANOVRA MANUALE ELETTRICA
Operating temperature: ENTRANCE FORBIDDEN
CAUTION!

+ 5°C ÷ + 50°C
EDERE AL QUADRO DI MANOVRA; WITHOUT AUTHORIZATION
for domoFLEX ▼ ARE PEOPLE INSIDE THE CAR,

1) MAKE SURE ALL THE LANDING


VARE A RIPRISTINARE IL FUNZIONAMENTO ESEGUENDO UN
ET O REALIZZANDO DEI COLLEGAMENTI TEMPORANEI. FARE DOORS ARE CLOSED;
CAUTION!
5) PRESS THE “EMERGENCY” BUTTON

4) ET “MAINTENANCE MODE” BY
3) IDENTIFY PLATFORM POSITION;

2) MAKE SURE THERE IS NO(CLOCKWISE);

1) MAKE SURE ALL THE4)LANDING

RIMENTO ALLO SCHEMA ELETTRICO E ALLA DIAGNOSTICA DEL RECOMMENDED OIL 2) MAKE SURE THERE IS NO ONE
EMERGENCY OPERATION

EMERGENCY KEY
FLOOR;
UP OR DOWN TO THE NEAREST
IN ORDER TO MAKE THE CAR MOVE

(CLOCKWISE);
TURNING THE CENTRAL SELECTOR

ENTRANCES;
THEM TO KEEP CLEAR FROM
REASSURE THEM AND WARN
ARE PEOPLE INSIDE THEINCAR,
INSIDE THE CAR; IN CASE

DOORS ARE CLOSED; TURNING THE CENTRAL SELECTOR

FOR BEARINGS AND GEARS


THE CAR; INRECOMMENDED
DRO DI MANOVRA; PLATFORM MACHINERY
INSIDE CASE THERE
INSTRUCTIONS THEM

A: NEL CASO IN CUI NON FOSSE POSSIBILE RIPRISTINARE IL Synthetic oil ISO VG 220
DRIVING FORCE

ZIONAMENTO DEL QUADRO SEGUIRE LA PROCEDURE PER LA Viscosity number ≥ 195 ARE PEOPLE INSIDE HYDRAULIC
ENTRANCE FORBIDDEN
THE CAR, OIL
▼ for domoFLEX ▼

OVRA MANUALE MECCANICA. Operating temperature:


REASSURE
WITHOUT AUTHORIZATIONWARN
THEM AND
PLATFORM

+ 5°C ÷ + 50°C Mineral oil ISO VG 46


I TASTI SALITA – DISCESAUSE IT TOSUL
UNLOCK LANDING
FINO ALDOORS ONLY IN
VARE LA MODALITÀ MANUTENZIONE E MUOVERE LA MACCHINA THEM TO KEEP CLEAR FROM THE
SWITCH

Viscosity ≥ 100
FOR BEARINGS AND GEARS

PRESENTI TASTIERINO
Synthetic oil ISO VG 220

Operating temperature:

ENTRANCES;
Viscosity number ≥ 195

GIUNGIMENTO DEL PIANO CASE OF EMERGENCY OPERATIONS.


RECOMMENDED OIL

DI SBARCO; Working temperature: + 5°C ÷ + 70°C


6) LET PEOPLE COME OUT OF THE

5) PRESS

3) IDENTIFY PLATFORM POSITION;

2) MAKE SURE THERE IS NO ONE

1) MAKE SURE ALL THE LANDING

ERMINE DELLA MANOVRA RIPRISTINARE LO STATO DEL QUADRO; 3) IDENTIFY PLATFORM POSITION;
EMERGENCY OPERATION
CAR.

FLOOR;
UP OR DOWN TO THE NEAREST

ET “MAINTENANCE MODE” BY

ENTRANCES;
FOR TO KEEP CLEAR FROM THE
REASSURE THEM AND WARN

INSIDE THE CAR; IN CASE THERE

DOORS ARE CLOSED;


ONE
THERETHE “EMERGENCY” BUTTON

+ 5°C ÷ + 50°C
ORDER TO MAKE THE CAR MOVE

IDSELECTOR
NUMBER
INSTRUCTIONS FOR

MANOVRA MANUALE
• BEFORE UNLOCKING MECCANICA
THE LANDING DOOR ASSURE YOURSELF THAT THE LIFT
4) ET “MAINTENANCE MODE” BY
THE

IS STANDING STILL AND THE CABIN IS ATTENDING AT THE FLOOR


EDERE AL QUADRO
• AFTERDILANDING
MANOVRA;DOOR CLOSURE ASSURE YOURSELF THAT IT IS PROPERLY TURNING THE CENTRAL
RE IL SEZIONATORE
LOCKEDQF-2 E BLOCCARLO IN POSIZIONE OFF (CLOCKWISE);
ANTE
rev.6 IL LUCCHETTO IN DOTAZIONE;
RE IL CARTER LATERALE DELLA GUIDA E ACCEDERE 5) PRESS THE “EMERGENCY” AREALIFTBUTTON
S.r.l. by LIFTINGITALIA S.r.l.
BUFFER SERIAL NUMBER BUFFER SERIAL NUMBER
IN ORDER TO MAKE THE CAR MOVE
Via Caduti del Lavoro, 16 - 43058 Bogolese, Sorbolo (PR) - ITALY

LEFT RIGHT
ERALMENTE AL MOTORE;
STARE LA PARTE TERMINALE ESAGONALE DELL’ALBERO UP OR DOWN TO THE NEAREST
ORE CON UNA CHIAVE A CRICCHETTO O UN AVVITATORE CH. 13;
DANGER OF CRUSHING
FLOOR;

EMERGENCY KEY
I0021.52.1007_rev.6

TARE L’ALBERO MOTORE IN SENSO ORARIO PER FAR SCENDERE


6) LET PEOPLE COME OUT OF THE
CAR.ACTIVATE THE OVERHEAD SAFETY DEVICE
EDANA;

DRIVING FORCE
OPERAZIONE RISULTASSE DANGER OF
DIFFICOLTOSA,
I0021.52.1007_rev.6APRIRETHEUNO
USE OF
DEIEMERGENCY
2 BEFORE REACHING TO THE ROOF

PLATFORM
FALLING IN LEVA MANUALE.KEY IS PROHIBITED TO
NI DEL MOTORE CON L’APPOSITA UNAUTHORISED PERSONS THE SHAFT
USE IT TO UNLOCK LANDING DOORS ONLY IN
EMERGENCY KEYOPERATIONS.
EMERGENCY DESCENDING EMERGENCY ASCENDING
WHEN THE EMERGENCY MANOEUVRE
USE TO UNAUTHORISED USE TO UNAUTHORISED
CASE OF EMERGENCY
DRIVING FORCE
PERSONS IS PROHIBITED PERSONS IS PROHIBITED

HAS BEEN COMPLETED CLOSE AND


LOCK ALL LANDING DOORS PLATFORM ALARM
PLATFORM
• BEFORE UNLOCKING THE LANDING DOOR ASSURE YOURSELF THAT THE LIFT
USEISITSTANDING
TO UNLOCK LANDING
STILL AND THE CABINDOORS ONLYAT IN
IS ATTENDING THE FLOOR SWITCH
I0021.52.1003_rev.6

DANGER OF BRING THE PLATFORM AT THE LANDING LEVEL CASE OF EMERGENCY OPERATIONS.
• AFTER LANDING DOOR CLOSURE ASSURE YOURSELF THAT IT IS PROPERLY Wor
LOCKED

FALLING IN IF IT IS NOT POSSIBLE, THE RECOVERY OPERATIONS OF THE PEOPLE MUST BE CARRIED OUT • BEFORE UNLOCKING THESERIAL
LANDING DOOR ASSURE BUFFER
YOURSELFSERIAL
THAT THE LIFT
THE SHAFT
BUFFER NUMBER NUMBER
ONLY BY AUTHORIZED PERSONNEL
LEFT RIGHT
IS STANDING STILL AND THE CABIN IS ATTENDING AT THE FLOOR
• AFTER LANDING DOOR CLOSURE ASSURE YOURSELF THAT IT IS PROPERLY
LOCKED

BUFFER SERIAL NUMBER BUFFER SERIAL NUMBER


LEFT DANGER OF RIGHT THE USE OF EMERGENCY
KEY IS PROHIBITED TO
FALLING IN

DAN
THE SHAFT UNAUTHORISED PERSONS

WHEN THE EMERGENCY MANOEUVRE ACTIVAT


HAS BEEN COMPLETED
THE USE OF EMERGENCY CLOSE AND
DANGER OF
BEFORE
FALLING IN
THE SHAFT
LOCK ALL
KEY LANDING
IS PROHIBITED DOORS
TO
UNAUTHORISED PERSONS
PLATFO
DANGER OF
WHEN THE EMERGENCY MANOEUVRE
BRING THE PLAT
HAS BEEN COMPLETED CLOSE AND
LOCK ALL LANDING DOORSFALLING IN PLATFORM
IF IT IS NOT POSSIBLE,ALA
THE R
THE SHAFT ONLY BY AUTHORIZED PERSO

DANGER OF BRING THE PLATFORM AT


Apply on landing doors in case FALLING IN IF IT IS NOT POSSIBLE, THE RECOVERY OPERA
of platform installation in public THE SHAFT ONLY BY AUTHORIZED PERSONNEL

buildings.

OUT OF OUT
Apply on landing doors in case of
platform out of service.
SERVICE SERV
IM.TEC.125.EN_rev.0 | 63 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

THE REMOVABLE SPACER IS


BRAKES, MAKE SURE THAT
PARTS PROJECTION

THE SPECIFIC CARABINER


BEFORE TESTING SAFETY

SAFELY SECURED TO THE


BRACKETS BY MEANS OF
DANGER OF PARTS
INSTRUCTIONS IN CASE OF EMERGENCY OPERATIONS

4) CUT OFF THE POWER SUPPLY OF THE LIFT MOTOR DIRECTLY FROM THE
1) ASSURE YOURSELF THAT ALL THE LANDING DOORS ARE PROPERLY

IS IN THERE, COMFORT HIM AND ASK HIM NOT TO APPROACH CABIN

EMERGENCY MANUAL DESCENT UNTIL THE CABIN REACHES THE


2) ASSURE YOURSELF THAT THE CABIN IS EMPTY AND, IF SOMEONE

5) PUSH THE RED BUTTON ON THE PUMP UNIT TO ACTIVATE THE


DANGER OF CRUSHING!

WARNING!
WARNING! WARNING!
WARNING!CRUSHING
CRUSHING STOP SWITCH

CRUSHING
CRUSHING

6) LET THE PASSENGERS OUT OF THE CABIN.


• ACTIVATE THE SWITCH WHEN ENTERING THE PIT
PLATFORM
PLATFORMMACHINERY
MACHINERY • RELEASE THE SWITCH WHEN GOING OUT OF THE PIT

PRESS THE BUTTON


THIS LIFT IS EQUIPPED CHAINED TO THE
BEFORE
BEFORE
ENTERING
ENTERING
INTO
INTO
THETHE
PITPIT

3) LOCATE THE CABIN POSITION;


DESIRED FLOOR, AND
WITH AN EMERGENCY VOICE
• PLACE
• PLACE
THETHE
MECHANICAL
MECHANICALDEVICE
DEVICE
FORFORTHETHE ACTIVATE
ACTIVATETHETHESAFETY
SAFETYDEVICE
DEVICE COMMUNICATION SYSTEM
HOLD THROUGHOUT
THE ENTIRE TRAVEL
FROM
FROMOUTSIDE
OUTSIDETHETHESHAFT
SHAFT

FURTHER DOWN FLOOR;


SHAFT
SHAFT
PITPIT
DEFENSE
DEFENSEANDAND
ENABLE
ENABLEIT FROM
IT FROM
OUTSIDE
OUTSIDE
• GO
• GO
INTO
INTO
THETHE
PITPIT
ONLY
ONLY
WHEN
WHENTHETHE
ACOUSTIC
ACOUSTIC BEFORE
BEFOREENTERING
ENTERINGINTOINTOTHETHEPITPIT IN CASE OF SUDDEN LACK
SIGNAL
SIGNAL
IS OFF
IS OFF OF POWER SUPPLY,

MAIN SWITCH;
ENTRANCES;
PRESS AND HOLD THE BUTTON
OF THE LOWER FLOOR

RISK
RISKOFOFDAMAGE
DAMAGE

LOCKED;
IN CASE OF EMERGENCY,

I0021.52.1005_rev.6
WARNING!
WARNING!
JUST PRESS THE ALARM BUTTON IN CASE OF EMERGENCY
TOTOTHE
THESYSTEM
SYSTEM WARNING!
WARNING!CRUSHING
CRUSHING FOR A FEW SECONDS UNTIL THE WARNING!
WARNING!
CRUSHING
CRUSHING
CRUSHING
CRUSHING
CONNECTION IS ESTABLISHED PRESS TO STOP
PLATFORM
PLATFORMMACHINERY
MACHINERY PLATFORM
PLATFORMMACHINERY
TURN ASMACHINERY
INDICATED
TO UNLOCK

PLATFORM
PLATFORMMAIN
MAINSWITCH
SWITCH
BEFORE
BEFORE
ENTERING
ENTERING
INTOINTO
THE THE
PIT PIT
ACTIVATE
ACTIVATE
THETHE
SAFETY
SAFETYDEVICE
DEVICE
CUT
CUTOFF
OFFTHE
THEPOWER
POWERSUPPLY
SUPPLYONLY
ONLY ENTRANCE
ENTRANCEFORBIDDEN
FORBIDDEN • PLACE
• PLACE
THE MECHANICAL
THE MECHANICAL
DEVICE
DEVICE
FOR THE
FOR THE
I0021.52.1002_rev.6
I0021.52.1002_rev.6

SHAFT SHAFT
PIT DEFENSE
PIT DEFENSE
AND AND
ENABLE
ENABLE
IT FROM
IT FROM FROM
FROM
OUTSIDE
OUTSIDE
THETHE
SHAFT
SHAFT
WHEN
WHENTHE
THEPLATFORM
PLATFORMHAS
HASREACHED
REACHED WITHOUT
WITHOUTAUTHORIZATION
AUTHORIZATION OUTSIDE
OUTSIDE
BEFORE
BEFORE
ENTERING
ENTERING
INTOINTO
THETHE
PIT PIT
THE
THEFURTHER
FURTHERDOWN
DOWNFLOOR
FLOOR
• GO •INTO
GO INTO
THE PIT
THEONLY
PIT ONLY
WHENWHEN
THE ACOUSTIC
THE ACOUSTIC
SIGNALSIGNAL
IS OFF
IS OFF

RISK
RISK
OFOF
DAMAGE
DAMAGE
TOTO
THE
THE
SYSTEM
SYSTEM WARNING!
WARNING!
CRUSHING
CRUSHING
PLATFORM
PLATFORMMACHINERY
MACHINERY
EMERGENCY KEY
RECOMMENDED

DRIVING FORCE
HYDRAULIC OIL

PLATFORM
PLATFORM
PLATFORMMAIN
MAINSWITCH
SWITCH
Mineral oil ISO VG 46
USE IT TO UNLOCK LANDING DOORS ONLY IN

SWITCH
Viscosity ≥ 100
CASE OF EMERGENCY OPERATIONS. Working temperature: + 5°C ÷ + 70°C

ENTRANCE
ENTRANCE
FORBIDDEN
FORBIDDEN
ID NUMBER
• BEFORE UNLOCKING THE LANDING DOOR ASSURE YOURSELF THAT THE LIFT

CUT
CUTOFFOFF
THETHE
POWER
POWERSUPPLY
SUPPLYONLY
ONLY
IS STANDING STILL AND THE CABIN IS ATTENDING AT THE FLOOR

I0021.52.1002_rev.6
I0021.52.1002_rev.6
• AFTER LANDING DOOR CLOSURE ASSURE YOURSELF THAT IT IS PROPERLY
LOCKED

WHEN
WHEN THETHE
PLATFORM
PLATFORMHAS
HASREACHED
REACHEDLEFT WITHOUT
WITHOUT
AUTHORIZATION
AUTHORIZATION
AREALIFT S.r.l. by LIFTINGITALIA S.r.l.
BUFFER SERIAL NUMBER BUFFER SERIAL NUMBER Via Caduti del Lavoro, 16 - 43058 Bogolese, Sorbolo (PR) - ITALY

RIGHT

THETHE
FURTHER
FURTHERDOWN
DOWNFLOOR
FLOOR
DANGER OF CRUSHING
ACTIVATE THE OVERHEAD SAFETY DEVICE
THE USE OF EMERGENCY
DANGER OF
FALLING IN KEY IS PROHIBITED TO BEFORE REACHING TO THE ROOF
THE SHAFT UNAUTHORISED PERSONS
EMERGENCY DESCENDING EMERGENCY ASCENDING
WHEN THE EMERGENCY MANOEUVRE
USE TO UNAUTHORISED USE TO UNAUTHORISED
PERSONS IS PROHIBITED PERSONS IS PROHIBITED

HAS BEEN COMPLETED CLOSE AND


PLATFORM ALARM

EMERGENCY KEY
LOCK ALL LANDING DOORS

RECOMMENDED

I0021.52.1003_rev.6
DANGER OF BRING THE PLATFORM AT THE LANDING LEVEL
DRIVING FORCE

HYDRAULIC
FALLING IN OIL IF IT IS NOT POSSIBLE, THE RECOVERY OPERATIONS OF THE PEOPLE MUST BE CARRIED OUT
THE SHAFT ONLY BY AUTHORIZED PERSONNEL
PLATFORM

Mineral oil ISO VG 46


USE IT TO UNLOCK LANDING DOORS ONLY IN
SWITCH

Viscosity ≥ 100
CASE OF EMERGENCY OPERATIONS. Working temperature: + 5°C ÷ + 70°C

ID NUMBER
• BEFORE UNLOCKING THE LANDING DOOR ASSURE YOURSELF THAT THE LIFT
IS STANDING STILL AND THE CABIN IS ATTENDING AT THE FLOOR
• AFTER LANDING DOOR CLOSURE ASSURE YOURSELF THAT IT IS PROPERLY
LOCKED

AREALIFT S.r.l. by LIFTINGITALIA S.r.l.


BUFFER SERIAL NUMBER BUFFER SERIAL NUMBER Via Caduti del Lavoro, 16 - 43058 Bogolese, Sorbolo (PR) - ITALY

LEFT RIGHT
DANGER OF CRUSHING
DANGER OF
FALLING IN
THE USE OF EMERGENCY
KEY IS PROHIBITED TO
ACTIVATE THE OVERHEAD SAFETY DEVICE
BEFORE REACHING TO THE ROOF
FILL IN THE PLATE
THE SHAFT UNAUTHORISED PERSONS
EMERGENCY DESCENDING EMERGENCY ASCENDING
WHEN THE EMERGENCY MANOEUVRE
USE TO UNAUTHORISED USE TO UNAUTHORISED
PERSONS IS PROHIBITED PERSONS IS PROHIBITED

HAS BEEN COMPLETED CLOSE AND


IS IS IS

THE REMOVABLE SPACER IS


THAT

BRAKES, MAKE SURE THAT

PLATFORM ALARM
PROJECTION

PARTS PROJECTION
CARABINER

THE SPECIFIC CARABINER


SAFETY

BEFORE TESTING SAFETY


TO THE

SAFELY SECURED TO THE

LOCK ALL LANDING DOORS


OF OF OF

BRACKETS BY MEANS OF
PARTS

DANGER OF PARTS
SPACER

IMPORTANT
THAT
OPERATIONS

OPERATIONS
PROJECTION

CARABINER
BY MEANS
SAFETY

TO THE
PARTS
THE

4) CUT OFF THE POWER SUPPLY OF THE LIFT MOTOR DIRECTLY FROM THE
SURE
SPACER
THAT
OPERATIONS

PROJECTION

BY MEANS
CARABINER
SAFETY

TO THE
SECURED

I0021.52.1003_rev.6
PARTS

DANGER OF
THE

TESTING
SURE
SPACER

BRING THE PLATFORM AT THE LANDING LEVEL


REMOVABLE
PROPERLY

PROPERLY
OF
OPERATIONS

BY MEANS
MAKE
CABIN

CABIN
SECURED
FROM
THE

TESTING

SPECIFIC
SURE
REMOVABLE
PROPERLY

OF OF
THE

EMERGENCY MANUAL DESCENT UNTIL THE CABIN REACHES THE


IF SOMEONE

SOMEONE
DANGER

FALLING IN
BRACKETS
MAKE
CABIN

FROM

SECURED

Check the presence


SPECIFIC
TESTING

REMOVABLE
PROPERLY

PARTS
THE
IF SOMEONE

BRAKES,

SAFELY
DANGER

BEFORE

IF IT IS NOT POSSIBLE, THE RECOVERY OPERATIONS OF THE PEOPLE MUST BE CARRIED OUT
BRACKETS
MAKE
CABIN

FROM

THE

5) PUSH THE RED BUTTON ON THE PUMP UNIT TO ACTIVATE THE


SPECIFIC

THE SHAFT
DIRECTLY

REACHES

PARTS
APPROACH

IS IN THERE, COMFORT HIM AND ASK HIM NOT TO APPROACH


THE
IF SOMEONE

IFBRAKES,
SAFELY
BEFORE
INSTRUCTIONS IN CASE OF EMERGENCYDANGER

ONLY BY AUTHORIZED PERSONNEL


BRACKETS
THE
THE

THE

of the load plate


DIRECTLY

REACHES
APPROACH

1) ASSURE YOURSELF THAT ALL THE LANDING DOORS PARTS

2) ASSURE YOURSELF THAT THE CABIN IS EMPTY AND,BRAKES,


SAFELY
BEFORE

THETHE
ACTIVATE
THE

THETHE
ARE

ARE
DIRECTLY

REACHES
APPROACH

ACTIVATE

DANGER OF CRUSHING! DANGER


theOF CRUSHING!
ARE
EMERGENCY

supplied with
AND,

ACTIVATE
DOORS

DANGER OF CRUSHING!
ARE
OFEMERGENCY

CABIN
MOTOR
AND,
DOORS

DANGER OF CRUSHING!
OFOFEMERGENCY

TO

CABIN
MOTOR

STOP SWITCH controlSTOP SWITCH


AND,

panel.
DOORS

IS EMPTY

TO
NOTTO

CABIN
MOTOR

STOP
• ACTIVATESWITCH
IS EMPTY
LANDING

TOTO
UNIT
TO

THE
NOT

CABIN.

6) LET THE PASSENGERS OUT OF THE CABIN.

STOP SWITCH
LIFT

• ACTIVATE THE SWITCH WHEN ENTERING THE PIT


LANDING

IS EMPTY

THE SWITCH WHEN ENTERING THE PIT


UNIT
THE
HIM
NOT
I0021.52.0033

I0021.52.0033

I0021.52.0033

I0021.52.0033

I0021.52.0033

CABIN.
LIFT

• ACTIVATE • RELEASE THE SWITCH WHEN GOING OUT OF THE PIT


LANDING

THESWITCH
RELEASE THE SWITCHWHEN
WHENGOING
ENTERING THETHE
OUT OF PITPIT
UNTIL
UNIT
THE
HIM

PUMP

CABIN.
THE
LIFT

• ACTIVATE
CABIN

THESWITCH
RELEASE THE SWITCHWHEN
WHENGOING
ENTERING THETHE
OUT OF PITPIT
ASK

UNTIL
PUMP
HIM

THE
THE
THE

• RELEASE THE SWITCH WHEN GOING OUT OF THE PIT


CABIN
ASK

UNTIL

PRESS THE BUTTON PRESS THE BUTT


PUMP
OF

THE
THE

DESCENT
THE

THIS LIFT IS EQUIPPED THIS LIFT IS EQUIPPED


CABIN

THE
AND

CHAINED
THETO THE CHAINED TO TH
ASK

PRESS BUTTON
OF
CASE

OFOF

THE
POSITION;

3) LOCATE THE CABIN POSITION;


THE
ALL

SUPPLY

DESCENT

DESIRED FLOOR,THE
AND DESIRED FLOOR, A
THE

THIS
ANLIFT IS EQUIPPED
THE
AND

WITH EMERGENCY VOICE CHAINED


PRESS THETOBUTTON WITH AN EMERGENCY VOICE
OF
INCASE

POSITION;

HOLD THROUGHOUT HOLD THROUGHO


THE
ALL

OUT
SUPPLY

ON

DESIRED FLOOR, AND


DESCENT
HIM

THIS
WITH ANLIFT IS EQUIPPED
EMERGENCY VOICE
THE
AND

COMMUNICATION SYSTEM CHAINED


THE ENTIRE
TO THE
TRAVEL COMMUNICATION SYSTEM THE ENTIRE TRA
OF
ININCASE
THAT

THAT

HOLD THROUGHOUT
POSITION;
THE

OUT
ALL

ONON
SUPPLY

DESIRED FLOOR, AND


HIMHIM

FLOOR;

WITH AN EMERGENCY
COMMUNICATION VOICE
SYSTEM
FURTHER DOWN FLOOR;
BUTTON

THE ENTIRE TRAVEL


THAT

THAT
COMFORT

PASSENGERS

HOLD THROUGHOUT
OUT
FLOOR;
MANUAL

COMMUNICATION SYSTEM
BUTTON
POWER

THE ENTIRE TRAVEL


THAT

THAT
COMFORT

IN CASE OF SUDDEN LACK IN CASE OF SUDDEN LAC


PASSENGERS
YOURSELF

YOURSELF

MANUAL
CABIN

FLOOR;
BUTTON
POWER
INSTRUCTIONS

IN CASE OF SUDDEN LACK


COMFORT

OF POWER SUPPLY OF POWER SUPPLY,


PASSENGERS

PUSH PUSH PUSH PUSH PUSH


YOURSELF

YOURSELF

CABIN

MANUAL

,
DOWN
POWER
INSTRUCTIONS

IN CASE
OFAND OF
POWERSUDDEN
SUPPLYLACK
RED
YOURSELF

YOURSELF

CABIN

SWITCH;

MAIN SWITCH;

,
DOWN
ENTRANCES;

ENTRANCES;

PRESS HOLD THE BUTTON PRESS AND HOLD THE BUTT


INSTRUCTIONS

THE

OFAND
POWER SUPPLY
EMERGENCY
THE
THERE,

RED
SWITCH;

,
DOWN

OF THE LOWER FLOOR OF THE LOWER FLOOR


ENTRANCES;

PRESS HOLD THE BUTTON


THE

THE
EMERGENCY
THE
THERE,

RED

FURTHER
SWITCH;
LOCKED;

LOCKED;

OF AND
THE HOLD
LOWER FLOOR
OFF

IN CASE OF EMERGENCY, IN CASE OF EMERGENCY,


THE

I0021.52.1005_rev.6
ENTRANCES;

PRESS THE BUTTON


THE
ASSURE

ASSURE

LOCATE

THE
EMERGENCY
THE
THERE,

FURTHER

IN CASE OF EMERGENCY IN CASE OF EMERGEN


LOCKED;

OF THE LOWER FLOOR


OFF

JUSTINPRESS
CASE OF
THEEMERGENCY,
THE

I0021.52.1005_rev.6

ALARM BUTTON JUST PRESS THE ALARM BUTTON


1)ASSURE

ASSURE

PUSH
LOCATE

THE
MAIN

FURTHER
IN

CUT

IN CASE OF EMERGENCY
LET
LOCKED;

OFF

FORINAPRESS
JUST CASE OF
THEEMERGENCY,
ALARM BUTTON
THE

I0021.52.1005_rev.6

FEW SECONDS UNTIL THE FOR A FEW SECONDS UNTIL THE


1) 1)ASSURE

ASSURE

PUSH
LOCATE

MAIN
IS IN
IS

CUT

IN CASE OF EMERGENCY
LET

JUST
FOR APRESS THE
IS ALARM
FEW SECONDS
CONNECTION BUTTON
UNTIL THE
ESTABLISHED PRESS TO STOP CONNECTION IS ESTABLISHED PRESS TO STOP
PUSH
MAIN
IS IN

CUT 4)
3)
2)

5)

LET 6)

FOR A FEW SECONDS


CONNECTION UNTIL THE
IS ESTABLISHED PRESS
TURN TO STOP
AS INDICATED TURN AS INDICATED
I0021.52.0033

I0021.52.0033

I0021.52.0033

I0021.52.0033

I0021.52.0033

4) 4)
3) 3)
2) 2)

5) 5)

6) 6)

TOAS
UNLOCK
PRESS
TURN TO STOP
INDICATED TO UNLOCK
Apply inside the manual landing doors, on CONNECTION IS ESTABLISHED
TOAS
TURN UNLOCK
INDICATED
TO UNLOCK
the lock side.

64 PUSH
(70) | All rights reserved
PUSH PUSH PUSH PUSH IM.TEC.125.EN_rev.0 - January 2022
.52.1008_rev.6
14. Final checks and adjustments
WARNING
Perform the checks and adjustments described in the manual IM.TEC.126
“FINAL CHECKS” to consider the installation of the system as completed.

15. Platform noise


The sources of platform noise are the motor, the brake, and the shoes that slide on the guide rails, particularly
during lifting with full load (including maximum permissible overload).
The motor is located at the rear of the sling between the guide rails and behind the protective casing.
The user position is located inside the car, so the user is not directly subject to noise emissions from sources of
noise disturbance. Despite this assumption, as precautionary measure, measurements were taken directly around
the above sources, in an industrial environment without other machines in operation.
In the various configurations examined, all measurements resulted in sound pressure levels below 70dB(A).

IM.TEC.125.EN_rev.0 | 65 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

ANNEX 1
Anchoring to the shaft by means of plugs (mechanical or chemical)
SHAFT IN REINFORCED CONCRETE
Unless otherwise noted, all plugs are M10 in size and require a hole in the wall with 10 mm bit.

h1 = Hole minimum depth


Lt = Plug length
hef

d0 = Hole diameter
tfix = Fixable shim
tinst = Tightening torque
Ch = Wrench
hef = Anchoring depth

Carefully clean the hole before installation.

SHAFT IN LOAD-BEARING MASONRY


CAUTION

2500
The anchoring of the jambs in shaft in masonry (realized with
elements suitable for the construction of load-bearing/
structural masonry*), requires a reduction of the bracket pitch
in order to cope with the lower mechanical strength of the shaft piano “2”
wall.
* Building materials suitable for the realization of load-bearing walls also
in seismic areas, calculated and realized in compliance with the law in
force in the field in the installation sites
3000

(IT) - D.M. January 17, 2018 (Building technical standards 2018).

The bracket pitches are 1250 mm, starting from the pit bottom = 500 mm.
piano “1”
NOTICE
500 1250 ±100 1250 ±100 1250 ±100 1250 ±100

Always refer to the design drawing for installation.


3000

CAUTION
For all the cases not covered by the described types, a site
survey and a project by a qualified technician is necessary. piano “0”
200

66 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


ANCHORING in LOAD-BEARING MASONRY SHAFT WITH SOLID, COMPACT ELEMENTS
For the application of chemical anchors on load-bearing masonry with solid, compact elements, a special kit has
been developed (code F350.23.0026V01), consisting of:
• 16 x galvanized THREADED RODS M10x130 with 45° cut (anti-rotation);
• 2 x CARTRIDGES (300 ml each) of injection anchor*, usable with normal silicone guns;
• 2 x Universal MIXERS ø9 mm in addition to the 4 supplied with the cartridges.

* Applicable for solid and hollow elements in cement, natural stone.

Each kit is suitable for the installation of 8 guide rail fixing brackets, which correspond on average to one stop.
Therefore, by way of example, for a 3-stop system, 3 F350.23.0026V01 KITS will be required, with the positioning
of the brackets according to the example drawing.
Tfix
h1 = Hole minimum depth h1

Lb = Bar length
Lt = Plug length
d0 = Hole nominal diameter d0 Øb
Øb = Bar diameter
Tfix = Fixable shim

Calculation of the bar length: Lt

Lb = Lt + Tfix Lb

INSTALLATION SEQUENCE:

Carefully clean the hole before installation.

IM.TEC.125.EN_rev.0 | 67 (70)
- January 2022 All rights reserved
EN
DomoFlex 2®
INSTALLATION AND COMMISSIONING INSTRUCTIONS

ANCHORAGE in a LOAD-BEARING MASONRY SHAFT WITH HOLLOW ELEMENTS


The special kit F350.23.0025V01 for chemical bolts application is composed of:
• n° 16 zinc plated THREADED RODS 45° cut (anti rotation) (M10x130 GALVANISHED CHEMSET STUD);
• n° 2 pcs 300 ml CARTRIDGES of ANCHORING ADHESIVE*, to be used with standard caulking guns (skeleton
gun);
• n° 2 multipurpose MIXERS ø9 mm, additionally to the 4 mixers foreseen for the cartridges;
• n° 2 FINE METAL MESH SLEEVE ø16 mm, length 1 mt each.

* Valido per elementi in: calcestruzzo, pietra naturale, mattone pieno e semipieno.

Each kit is sufficient for 8 brackets, required for approx. 1 stop.


For instance, 3 F350.23.0025V01 kitskits are required for a 3 stops’ lift, the brackets being positioned as per the
sample drawing.

Tfix
h1 = Minimum hole depth h1

Lb = Rods length
Lt = Dowel length
d0 = Hole diameter
d0
db Øb
db = Metal Mesh Sleeve diameter
Øb = Rods diameter
T fix Fixable thickness
Lt

Threaded rods length calculation: Lb

L b = L t + T fix

ASSEMBLY SEQUENCE

Carefully clean the hole before installation.

68 (70) | All rights reserved IM.TEC.125.EN_rev.0 - January 2022


IM.TEC.125.EN_rev.0 | 69 (70)
- January 2022 All rights reserved
EN
LIFTING ITALIA S.r.l.
Via Caduti del Lavoro, 16
43058 Bogolese di Sorbolo - Parma, Italy
Tel. +39 0521 695311
www.liftingitalia.com

AREALIFT S.r.l.
Via Caduti del Lavoro, 22
43058 Bogolese di Sorbolo - Parma, Italy
Tel. +39 0521 695311
www.arealift.com
info@arealift.com
TECHNICAL SUPPORT
Tel. +39 0521 695328
support@arealift.com

You might also like