I/O LIST

PO Number: PO Title:

Equipment Name (if applicable): Equipment No:

Review/Approval Stamp:
Review Status (Pls. tick against letter)
Approved to proceed. (Submit final documents in VDR
1 only). Manufacture may proceed.

Approved to proceed except as noted (Revise and submit


2 document). Manufacture may proceed once comments
actioned.
Not approved. (Revise and resubmit). Work may NOT
3 proceed.

Information only. (Resubmit final documents in VDR


4 only). Manufacture may proceed.

Vendor's Document No. Reviewer's Name: ____________________________

Signature: ____________________________

Date: ____________________________
Notes:
Rev. Date Document Issue Purpose Prepared By Checked By Approved By
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
FIELD TB'S
CHN TYPE

ENG UNIT
Max EU
Field

Min EU

LO-LO
SL NO

RACK

SLOT

HI-HI
CHN

LO
I/O Controller Tag Address TAG NAME DESCRIPTION Contact COMMENTS

HI
From

1 0 - - - - - - Interface Module

1 1 0 DI UPS Battery Room Inline Fan MCC- Local/Remote mode


1 1 1 DI UPS Battery Room Inline Fan Run Status
1 1 2 DI UPS Battery Room Inline Fan Trip Status
1 1 3 DI S11_MCP_LDB_PL_1/PA_01_ON/OFF_ST LDB On/ Off Status LDB 1/PA-01
1 1 4 DI S11_MCP_LDB_PL_1/PA_02_ON/OFF_ST LDB On/ Off Status LDB 1/PA-02
1 1 5 DI S11_MCP_LDB_PL_1/PA_03_ON/OFF_ST LDB On/ Off Status LDB 1/PA-03
1 1 6 DI S11_MCP_LDB_PL_1/PA_04_ON/OFF_ST LDB On/ Off Status LDB 1/PA-04
1 1 7 DI S11_MCP_LDB_PL_1/PA_05_ON/OFF_ST LDB On/ Off Status LDB 1/PA-05
1 1 8 DI S11_MCP_LDB_PL_1/PA_06_ON/OFF_ST LDB On/ Off Status LDB 1/PA-06
1 1 9 DI S11_MCP_LDB_PL_1/PB_01_ON/OFF_ST LDB On/ Off Status LDB 1/PB-01
1 1 10 DI S11_MCP_LDB_PL_1/PB_02_ON/OFF_ST LDB On/ Off Status LDB 1/PB-02
1 1 11 DI S11_MCP_LDB_PL_1/PB_03_ON/OFF_ST LDB On/ Off Status LDB 1/PB-03
1 1 12 DI S11_MCP_LDB_PL_1/PB_04_ON/OFF_ST LDB On/ Off Status LDB 1/PB-04
1 1 13 DI S11_MCP_LDB_PL_1/PB_05_ON/OFF_ST LDB On/ Off Status LDB 1/PB-05
1 1 14 DI S11_MCP_LDB_PL_1/PB_06_ON/OFF_ST LDB On/ Off Status LDB 1/PB-06
1 1 15 DI S11_MCP_LDB_CL_1/CB_01_ON/OFF_ST LDB On/ Off Status LDB 1/CB-01

1 2 0 DI S11_MCP_LDB_CL_1/CB_02_ON/OFF_ST LDB On/ Off Status LDB 1/CB-02


1 2 1 DI S11_MCP_LDB_CL_1/CB_03_ON/OFF_ST LDB On/ Off Status LDB 1/CB-03
1 2 2 DI S11_MCP_LDB_CL_1/CB_04_ON/OFF_ST LDB On/ Off Status LDB 1/CB-04
1 2 3 DI S11_MCP_LDB_CL_1/CB_05_ON/OFF_ST LDB On/ Off Status LDB 1/CB-05
1 2 4 DI S11_MCP_LDB_CL_1/CB_06_ON/OFF_ST LDB On/ Off Status LDB 1/CB-06
1 2 5 DI S11_MCP_LDB_CL_1/CC_01_ON/OFF_ST LDB On/ Off Status LDB 1/CC-01
1 2 6 DI S11_MCP_LDB_CL_1/CC_02_ON/OFF_ST LDB On/ Off Status LDB 1/CC-02
1 2 7 DI S11_MCP_LDB_CL_1/CC_03_ON/OFF_ST LDB On/ Off Status LDB 1/CC-03
1 2 8 DI S11_MCP_LDB_CL_1/CC_04_ON/OFF_ST LDB On/ Off Status LDB 1/CC-04
1 2 9 DI S11_MCP_LDB_CL_1/CC_05_ON/OFF_ST LDB On/ Off Status LDB 1/CC-05
1 2 10 DI S11_MCP_LDB_CL_1/CC_06_ON/OFF_ST LDB On/ Off Status LDB 1/CC-06
1 2 11 DI Spare
1 2 12 DI Spare
1 2 13 DI Spare
1 2 14 DI Spare
1 2 15 DI Spare

1 3 0 DI Spare
1 3 1 DI Spare
1 3 2 DI Spare
1 3 3 DI Spare
1 3 4 DI Spare
1 3 5 DI Spare
1 3 6 DI Spare
1 3 7 DI Spare
1 3 8 DI Spare
1 3 9 DI Spare
1 3 10 DI Spare
1 3 11 DI Spare
1 3 12 DI Spare
1 3 13 DI Spare
1 3 14 DI Spare
1 3 15 DI Spare

1 4 0 DO UPS Battery Room Inline Fan - Run Command


1 4 1 DO S11_MCP_LDB_PL_1/PA_01_ON/OFF_CMD LDB On/ Off Command LDB 1/PA-01
1 4 2 DO S11_MCP_LDB_PL_1/PA_02_ON/OFF_CMD LDB On/ Off Command LDB 1/PA-02
1 4 3 DO S11_MCP_LDB_PL_1/PA_03_ON/OFF_CMD LDB On/ Off Command LDB 1/PA-03
1 4 4 DO S11_MCP_LDB_PL_1/PA_04_ON/OFF_CMD LDB On/ Off Command LDB 1/PA-04
1 4 5 DO S11_MCP_LDB_PL_1/PA_05_ON/OFF_CMD LDB On/ Off Command LDB 1/PA-05
1 4 6 DO S11_MCP_LDB_PL_1/PA_06_ON/OFF_CMD LDB On/ Off Command LDB 1/PA-06
1 4 7 DO S11_MCP_LDB_PL_1/PB_01_ON/OFF_CMD LDB On/ Off Command LDB 1/PB-01

1 5 0 DO S11_MCP_LDB_PL_1/PB_02_ON/OFF_CMD LDB On/ Off Command LDB 1/PB-02


1 5 1 DO S11_MCP_LDB_PL_1/PB_03_ON/OFF_CMD LDB On/ Off Command LDB 1/PB-03
1 5 2 DO S11_MCP_LDB_PL_1/PB_04_ON/OFF_CMD LDB On/ Off Command LDB 1/PB-04
1 5 3 DO S11_MCP_LDB_PL_1/PB_05_ON/OFF_CMD LDB On/ Off Command LDB 1/PB-05
1 5 4 DO S11_MCP_LDB_PL_1/PB_06_ON/OFF_CMD LDB On/ Off Command LDB 1/PB-06
1 5 5 DO S11_MCP_LDB_CL_1/CB_01_ON/OFF_CMD LDB On/ Off Command LDB 1/CB-01

Project : OYO Project FPSO Reciprocating Gas Compressor Page 3 of 51


Client : Technics Offshore Engineering Pte Ltd
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
FIELD TB'S
CHN TYPE

ENG UNIT
Max EU
Field

Min EU

LO-LO
SL NO

RACK

SLOT

HI-HI
CHN

LO
I/O Controller Tag Address TAG NAME DESCRIPTION Contact COMMENTS

HI
From

1 5 6 DO S11_MCP_LDB_CL_1/CB_02_ON/OFF_CMD LDB On/ Off Command LDB 1/CB-02


1 5 7 DO S11_MCP_LDB_CL_1/CB_03_ON/OFF_CMD LDB On/ Off Command LDB 1/CB-03

1 6 0 DO S11_MCP_LDB_CL_1/CB_04_ON/OFF_CMD LDB On/ Off Command LDB 1/CB-04


1 6 1 DO S11_MCP_LDB_CL_1/CB_05_ON/OFF_CMD LDB On/ Off Command LDB 1/CB-05
1 6 2 DO S11_MCP_LDB_CL_1/CB_06_ON/OFF_CMD LDB On/ Off Command LDB 1/CB-06
1 6 3 DO S11_MCP_LDB_CL_1/CC_01_ON/OFF_CMD LDB On/ Off Command LDB 1/CC-01
1 6 4 DO S11_MCP_LDB_CL_1/CC_02_ON/OFF_CMD LDB On/ Off Command LDB 1/CC-02
1 6 5 DO S11_MCP_LDB_CL_1/CC_03_ON/OFF_CMD LDB On/ Off Command LDB 1/CC-03
1 6 6 DO S11_MCP_LDB_CL_1/CC_04_ON/OFF_CMD LDB On/ Off Command LDB 1/CC-04
1 6 7 DO S11_MCP_LDB_CL_1/CC_05_ON/OFF_CMD LDB On/ Off Command LDB 1/CC-05

1 7 0 DO S11_MCP_LDB_CL_1/CC_06_ON/OFF_CMD LDB On/ Off Command LDB 1/CC-06


1 7 1 DO Spare
1 7 2 DO Spare
1 7 3 DO Spare
1 7 4 DO Spare
1 7 5 DO Spare
1 7 6 DO Spare
1 7 7 DO Spare

1 8 0 F-DI S11_MCP_CL_FACP_FIRE_ALRM Fire Alarm Panel - Panel in Fire Alert Condition


1 8 1 F-DI ASS Room UPS -01 Incoming Breaker Status (Active & Standby)
1 8 2 F-DI ASS Room UPS - 01 Outgoing Breaker Status (Active & Standby)
1 8 3 F-DI ASS Room UPS - 01 Discharging Mode Alert VFC
1 8 4 F-DI ASS Room UPS -02 Incoming Breaker Status (Active & Standby)
1 8 5 F-DI ASS Room UPS - 02 Outgoing Breaker Status (Active & Standby)
1 8 6 F-DI ASS Room UPS - 02 Discharging Mode Alert VFC
1 8 7 F-DI S11_MCP_PL_LFT_1_FIRE_ALRM Lift-01 Fire Mode status

1 9 0 F-DI S11_MCP_PL_LFT_2_FIRE_ALRM Lift-02 Fire Mode status


1 9 1 F-DI S11_MCP_PL_LFT_3_FIRE_ALRM Lift-03 Fire Mode status
1 9 2 F-DI S11_MCP_PL_ESCL_1_FIRE_ALRM
_ESCL_2 Escalator-01 Fire Mode status
1 9 3 F-DI _FIRE_ALRM Escalator-02 Fire Mode status
1 9 4 F-DI Spare
1 9 5 F-DI Spare
1 9 6 F-DI Spare
1 9 7 F-DI Spare

1 10 0 F-AI S11_MCP_VAC_CL_SCR_TEMP SCR Room Temperature


1 10 1 F-AI S11_MCP_VAC_CL_SCR_RH SCR Room Humidity
1 10 2 F-AI UPS Room Temperature
1 10 3 F-AI UPS Room Humidity

1 11 0 F-AI UPS Battery Room Temperature


1 11 1 F-AI UPS Battery Room Humidity
1 11 2 F-AI UPS Battery Room Hydrogen Sensor
1 11 3 F-AI Spare

1 12 0 F-AI Spare
1 12 1 F-AI Spare
1 12 2 F-AI Spare
1 12 3 F-AI Spare

1 13 0 AQ Spare
1 13 1 AQ Spare
1 13 2 AQ Spare
1 13 3 AQ Spare

1 14 0 AQ Spare
1 14 1 AQ Spare
1 14 2 AQ Spare
1 14 3 AQ Spare

1 15 CM Ptp

Project : OYO Project FPSO Reciprocating Gas Compressor Page 4 of 51


Client : Technics Offshore Engineering Pte Ltd
FIELD TB'S
CHN TYPE
SL NO

RACK

SLOT

CHN

I/O Controller Tag Address

1 0 - - - - - -

1 1 0 DI S11_RIO1_LV_CL_ACDB_ON/OFF_ST
1 1 1 DI S11_RIO1_LV_CL_ACDB_TRIP
1 1 2 DI S11_RIO1_VAC_CL_ACODU_1_FLT_ALRM
1 1 3 DI S11_RIO1_VAC_CL_ACODU_2_FLT_ALRM
1 1 4 DI S11_RIO1_VAC_CL_ACODU_3_FLT_ALRM
1 1 5 DI S11_RIO1_S&T _INF_OP_L/R
1 1 6 DI S11_RIO1_S&T_INF_RUN_ST
1 1 7 DI S11_RIO1_S&T_INF_CB_TRIP
1 1 8 DI S11_RIO1_LDB_CL_1/CA_01_ON/OFF_ST
1 1 9 DI S11_RIO1_LDB_CL_1/CA_02_ON/OFF_ST
1 1 10 DI S11_RIO1_LDB_CL_1/CA_03_ON/OFF_ST
1 1 11 DI S11_RIO1_LDB_CL_1/CA_04_ON/OFF_ST
1 1 12 DI S11_RIO1_LDB_CL_1/CA_05_ON/OFF_ST
1 1 13 DI S11_RIO1_LDB_CL_1/CA_06_ON/OFF_ST
1 1 14 DI
1 1 15 DI

1 2 0 DI
1 2 1 DI
1 2 2 DI
1 2 3 DI
1 2 4 DI
1 2 5 DI
1 2 6 DI
1 2 7 DI
1 2 8 DI
1 2 9 DI
1 2 10 DI
1 2 11 DI
1 2 12 DI
1 2 13 DI
1 2 14 DI
1 2 15 DI

1 3 0 DO S11_RIO1_VAC_CL_ACODU_1_ON/OFF_CMD
1 3 1 DO S11_RIO1_VAC_CL_ACODU_2_ON/OFF_CMD
1 3 2 DO S11_RIO1_VAC_CL_ACODU_3_ON/OFF_CMD
1 3 3 DO S11_RIO1_S&T_INF_RUN_CMD
1 3 4 DO S11_RIO1_LDB_CL_1/CA_01_ON/OFF_CMD
1 3 5 DO S11_RIO1_LDB_CL_1/CA_02_ON/OFF_CMD
1 3 6 DO S11_RIO1_LDB_CL_1/CA_03_ON/OFF_CMD
1 3 7 DO S11_RIO1_LDB_CL_1/CA_04_ON/OFF_CMD

1 4 0 DO S11_RIO1_LDB_CL_1/CA_05_ON/OFF_CMD
1 4 1 DO S11_RIO1_LDB_CL_1/CA_06_ON/OFF_CMD
1 4 2 DO
1 4 3 DO
1 4 4 DO
1 4 5 DO
1 4 6 DO
1 4 7 DO

1 5 0 F-DI _FLOW_SW_ST_01
1 5 1 F-DI _FLOW_SW_ST_02
1 5 2 F-DI _FLOW_SW_ST_03
1 5 3 F-DI _FLOW_SW_ST_04
1 5 4 F-DI _FLOW_SW_ST_05
1 5 5 F-DI _FLOW_SW_ST_06
1 5 6 F-DI _FLOW_SW_ST_07
1 5 7 F-DI _FLOW_SW_ST_08

1 6 0 F-DI S11_RIO1_CL_FLOW_SW_ST_09
1 6 1 F-DI S11_RIO1_CL_FLOW_SW_ST_10
1 6 2 F-DI S11_RIO1_CL_FLOW_SW_ST_11
1 6 3 F-DI S11_RIO1_CL_FLOW_SW_ST_11
1 6 4 F-DI S11_RIO1_S&T_LV_CL_UPS 1_INCOMR_ST
1 6 5 F-DI S11_RIO1_S&T_LV_CL_UPS 1_OUTR_ST
1 6 6 F-DI S11_RIO1_S&T_LV_CL_UPS 1_DISR_ST
1 6 7 F-DI S11_RIO1_S&T_LV_CL_UPS 2_INCOMR_ST

1 7 0 F-DI S11_RIO1_S&T_LV_CL_UPS 2_OUTR_ST


1 7 1 F-DI S11_RIO1_S&T_LV_CL_UPS 2_DISR_ST
1 7 2 F-DI S11_RIO1_PL_ESCL_3_FIRE_ALRM
_ESCL_4
1 7 3 F-DI _FIRE_ALRM
1 7 4 F-DI
1 7 5 F-DI
1 7 6 F-DI
1 7 7 F-DI

1 8 0 F-AI S11_RIO1_VAC_CL_O&M_TEMP
1 8 1 F-AI S11_RIO1_VAC_CL_O&M_RH
1 8 2 F-AI S11_RIO1_VAC_CL_S&T_TEMP
1 8 3 F-AI S11_RIO1_VAC_CL_S&T_RH

1 9 0 F-AI S11_RIO1_VAC_CL_S&T_BATT_H2
1 9 1 F-AI
1 9 2 F-AI
1 9 3 F-AI

1 10 0 AQ
1 10 1 AQ
1 10 2 AQ
1 10 3 AQ

1 11 0 AQ
1 11 1 AQ
1 11 2 AQ
1 11 3 AQ

1 12 CM Ptp
Field
TAG NAME DESCRIPTION Contact
From

Interface Module

ACDB incomer On/ Off Status


ACDB incomer Trip Status
Ducted Split AC-01 ODU - Run Failure/ General Alarm Status
Ducted Split AC-02 ODU - Run Failure/ General Alarm Status
Ducted Split AC-03 ODU - Run Failure/ General Alarm Status
S&T UPS & Battery room Inline FAN MCC - Local/ Remote Mode
S&T UPS & Battery room Inline FAN MCC - Run Status
S&T UPS & Battery room Inline FAN MCC - Trip Status
LDB On/ Off Status LDB 1/CA-01
LDB On/ Off Status LDB 1/CA-02
LDB On/ Off Status LDB 1/CA-03
LDB On/ Off Status LDB 1/CA-04
LDB On/ Off Status LDB 1/CA-05
LDB On/ Off Status LDB 1/CA-06
Spare
Spare

Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare

Ducted Split AC-01 ODU - On/Off Command


Ducted Split AC-02 ODU - On/Off Command
Ducted Split AC-03 ODU - On/Off Command
S&T UPS & Battery room Inline Fan Run Command
LDB On/ Off Command LDB 1/CA-01
LDB On/ Off Command LDB 1/CA-02
LDB On/ Off Command LDB 1/CA-03
LDB On/ Off Command LDB 1/CA-04

LDB On/ Off Command LDB 1/CA-05


LDB On/ Off Command LDB 1/CA-06
Spare
Spare
Spare
Spare
Spare
Spare

Water Flow Status (VFC)-01


Water Flow Status (VFC)-02
Water Flow Status (VFC)-03
Water Flow Status (VFC)-04
Water Flow Status (VFC)-05
Water Flow Status (VFC)-06
Water Flow Status (VFC)-07
Water Flow Status (VFC)-08

Water Flow Status (VFC)-09


Water Flow Status (VFC)-10
Water Flow Status (VFC)-11
Water Flow Status (VFC)-12
CP07, S&T ROOM UPS-01 Incoming breaker status
CP07, S&T ROOM UPS-01 Outgoing breaker status
CP07, S&T ROOM UPS-01 Discharging Mode Alert VFC
CP07, S&T ROOM UPS-02 Incoming breaker status

CP07, S&T ROOM UPS-02 Outgoing breaker status


CP07, S&T ROOM UPS-02 Discharging Mode Alert VFC
Escalator-03 Fire Mode status
Escalator-04 Fire Mode status
Spare
Spare
Spare
Spare

O&M Room Temperature


O&M Room Humidity
S&T Room Temperature
S&T Room Humidity

S&T UPS & Battery Room Hydrogen Sensor


Spare
Spare
Spare

Spare
Spare
Spare
Spare

Spare
Spare
Spare
Spare
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
ENG UNIT
Max EU
Min EU

LO-LO

HI-HI
LO

HI
COMMENTS
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
FIELD TB'S
CHN TYPE

ENG UNIT
Max EU
Field

Min EU

LO-LO
SL NO

RACK

SLOT

HI-HI
CHN

LO
I/O Controller Tag Address TAG NAME DESCRIPTION Contact COMMENTS

HI
From

1 0 - - - - - - Interface Module

1 1 0 DI S11_RIO2_LV_CL_MDB_INCOMR_1_CB_L/R ACB-01 Breaker - REMOTE mode status (MDB-Incoming)


1 1 1 DI S11_RIO2_LV_CL_MDB_INCOMR_1_CB_TEST ACB-01 Breaker TEST position status (MDB-Incoming)
1 1 2 DI S11_RIO2_LV_CL_MDB_INCOMR_1_CB_SERVICE ACB-01 Breaker Service status (MDB-Incoming)
1 1 3 DI S11_RIO2_LV_CL_MDB_INCOMR_2_CB_L/R ACB-02 Breaker - REMOTE mode status (MDB-Incoming)
1 1 4 DI S11_RIO2_LV_CL_MDB_INCOMR_2_CB_TEST ACB-02 Breaker TEST position status (MDB-Incoming)
1 1 5 DI S11_RIO2_LV_CL_MDB_INCOMR_2_CB_SERVICE ACB-02 Breaker Service status (MDB-Incoming)
1 1 6 DI S11_RIO2_LV_CL_MDB_INCOMR_3_CB_L/R ACB-03 Breaker - REMOTE mode status (MDB-Incoming)
1 1 7 DI S11_RIO2_LV_CL_MDB_INCOMR_3_CB_TEST ACB-03 Breaker TEST position status (MDB-Incoming)
1 1 8 DI S11_RIO2_LV_CL_MDB_INCOMR_3_CB_SERVICE ACB-03 Breaker Service status (MDB-Incoming)
1 1 9 DI S11_RIO2_LV_CL_ESPP_INCOMR_CB_ST ESPP On/ Off Status (Incoming)
1 1 10 DI S11_RIO2_LV_CL_ESPP_INCOMR_CB_TRIP ESPP Trip Status (Incoming)
1 1 11 DI S11_RIO2_LV_CL_MLP_INCOMR_CB_ST MLP On/ Off Status (Incoming)
1 1 12 DI S11_RIO2_LV_CL_MLP_INCOMR_CB_TRIP MLP Trip Status (Incoming)
1 1 13 DI S11_RIO2_LV_CL_ACPP_INCOMR_CB_ST ACPP On/ Off Status (Incoming)
1 1 14 DI S11_RIO2_LV_CL_ACPP_INCOMR_CB_TRIP ACPP Trip Status (Incoming)
1 1 15 DI S11_RIO2_LV_CL_RAP_INCOMR_CB_ST RAP On/ Off Status (Incoming)

1 2 0 DI S11_RIO2_LV_CL_RAP_INCOMR_CB_TRIP RAP Trip Status (Incoming)


1 2 1 DI S11_RIO2_LV_CL_EACDB_INCOMR_CB_ST EACDB On/ Off Status (Incoming)
1 2 2 DI S11_RIO2_LV_CL_EACDB_INCOMR_CB_TRIP EACDB Trip Status (Incoming)
1 2 3 DI S11_RIO2_LV_CL_EMLP_INCOMR1_CB_ST EMLP On/ Off Status-01 (Incoming)
1 2 4 DI S11_RIO2_LV_CL_EMLP_INCOMR1_CB_TRIP EMLP Trip Status-01 (Incoming)
1 2 5 DI S11_RIO2_LV_CL_EMLP_INCOMR2_CB_ST EMLP On/ Off Status-02 (Incoming)
1 2 6 DI S11_RIO2_LV_CL_EMLP_INCOMR2_CB_TRIP EMLP Trip Status-02 (Incoming)
1 2 7 DI S11_RIO2_LV_CL_MDB_OUTR1_CB_ST MDB On/ Off Status-01 (Outgoing)
1 2 8 DI S11_RIO2_LV_CL_MDB_OUTR1_CB_TRIP MDB Trip Status-01 (Outgoing)
1 2 9 DI S11_RIO2_LV_CL_MDB_OUTR2_CB_ST MDB On/ Off Status-02 (Outgoing)
1 2 10 DI S11_RIO2_LV_CL_MDB_OUTR2_CB_TRIP MDB Trip Status-02 (Outgoing)
1 2 11 DI S11_RIO2_LV_CL_MDB_OUTR3_CB_ST MDB On/ Off Status-03 (Outgoing)
1 2 12 DI S11_RIO2_LV_CL_MDB_OUTR3_CB_TRIP MDB Trip Status-03 (Outgoing)
1 2 13 DI S11_RIO2_LV_CL_MDB_OUTR4_CB_ST MDB On/ Off Status-04 (Outgoing)
1 2 14 DI S11_RIO2_LV_CL_MDB_OUTR4_CB_TRIP MDB Trip Status-04 (Outgoing)
1 2 15 DI S11_RIO2_LV_CL_MDB_OUTR5_CB_ST MDB On/ Off Status-05 (Outgoing)

1 3 0 DI S11_RIO2_LV_CL_MDB_OUTR5_CB_TRIP MDB Trip Status-05 (Outgoing)


1 3 1 DI S11_RIO2_LV_CL_MDB_OUTR6_CB_ST MDB On/ Off Status-06 (Outgoing)
1 3 2 DI S11_RIO2_LV_CL_MDB_OUTR6_CB_TRIP MDB Trip Status-06 (Outgoing)
1 3 3 DI S11_RIO2_LV_CL_MDB_OUTR7_CB_ST MDB On/ Off Status-07 (Outgoing)
1 3 4 DI S11_RIO2_LV_CL_MDB_OUTR7_CB_TRIP MDB Trip Status-07 (Outgoing)
1 3 5 DI S11_RIO2_LV_CL_MDB_OUTR8_CB_ST MDB On/ Off Status-08 (Outgoing)
1 3 6 DI S11_RIO2_LV_CL_MDB_OUTR8_CB_TRIP MDB Trip Status-08 (Outgoing)
1 3 7 DI S11_RIO2_LV_CL_MDB_OUTR9_CB_ST MDB On/ Off Status-09 (Outgoing)
1 3 8 DI S11_RIO2_LV_CL_MDB_OUTR9_CB_TRIP MDB Trip Status-09 (Outgoing)
1 3 9 DI S11_RIO2_LV_CL_MDB_OUTR10_CB_ST MDB On/ Off Status-10 (Outgoing)
1 3 10 DI S11_RIO2_LV_CL_MDB_OUTR10_CB_TRIP MDB Trip Status-10 (Outgoing)
1 3 11 DI S11_RIO2_LV_CL_MDB_OUTR11_CB_ST MDB On/ Off Status-11 (Outgoing)
1 3 12 DI S11_RIO2_LV_CL_MDB_OUTR11_CB_TRIP MDB Trip Status-11 (Outgoing)
1 3 13 DI S11_RIO2_LV_CL_MDB_OUTR12_CB_ST MDB On/ Off Status-12 (Outgoing)
1 3 14 DI S11_RIO2_LV_CL_MDB_OUTR12_CB_TRIP MDB Trip Status-12 (Outgoing)
1 3 15 DI S11_RIO2_LV_CL_MDB_OUTR13_CB_ST MDB On/ Off Status-13 (Outgoing)

1 4 0 DI S11_RIO2_LV_CL_MDB_OUTR13_CB_TRIP MDB Trip Status-13 (Outgoing)


1 4 1 DI S11_RIO2_LV_CL_MDB_OUTR14_CB_ST MDB On/ Off Status-14 (Outgoing)
1 4 2 DI S11_RIO2_LV_CL_MDB_OUTR14_CB_TRIP MDB Trip Status-14 (Outgoing)
1 4 3 DI S11_RIO2_LV_CL_MDB_OUTR15_CB_ST MDB On/ Off Status-15 (Outgoing)
1 4 4 DI S11_RIO2_LV_CL_MDB_OUTR15_CB_TRIP MDB Trip Status-15 (Outgoing)
1 4 5 DI S11_RIO2_LV_CL_MDB_OUTR16_CB_ST MDB On/ Off Status-16 (Outgoing)
1 4 6 DI S11_RIO2_LV_CL_MDB_OUTR16_CB_TRIP MDB Trip Status-16 (Outgoing)
1 4 7 DI S11_RIO2_LV_CL_ESPP_OUTR1_CB_ST ESPP On/ Off Status-01 (Outgoing)
1 4 8 DI S11_RIO2_LV_CL_ESPP_OUTR1_CB_TRIP ESPP Trip Status-01 (Outgoing)
1 4 9 DI S11_RIO2_LV_CL_ESPP_OUTR2_CB_ST ESPP On/ Off Status-02 (Outgoing)
1 4 10 DI S11_RIO2_LV_CL_ESPP_OUTR2_CB_TRIP ESPP Trip Status-02 (Outgoing)
1 4 11 DI S11_RIO2_LV_CL_ESPP_OUTR3_CB_ST ESPP On/ Off Status-03 (Outgoing)
1 4 12 DI S11_RIO2_LV_CL_ESPP_OUTR3_CB_TRIP ESPP Trip Status-03 (Outgoing)
1 4 13 DI S11_RIO2_LV_CL_ESPP_OUTR4_CB_ST ESPP On/ Off Status-04 (Outgoing)
1 4 14 DI S11_RIO2_LV_CL_ESPP_OUTR4_CB_TRIP ESPP Trip Status-04 (Outgoing)

Project : OYO Project FPSO Reciprocating Gas Compressor Page 17 of 51


Client : Technics Offshore Engineering Pte Ltd
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
FIELD TB'S
CHN TYPE

ENG UNIT
Max EU
Field

Min EU

LO-LO
SL NO

RACK

SLOT

HI-HI
CHN

LO
I/O Controller Tag Address TAG NAME DESCRIPTION Contact COMMENTS

HI
From

1 4 15 DI S11_RIO2_LV_CL_ESPP_OUTR5_CB_ST ESPP On/ Off Status-05 (Outgoing)

1 5 0 DI S11_RIO2_LV_CL_ESPP_OUTR5_CB_TRIP ESPP Trip Status-05 (Outgoing)


1 5 1 DI S11_RIO2_LV_CL_ESPP_OUTR6_CB_ST ESPP On/ Off Status-06 (Outgoing)
1 5 2 DI S11_RIO2_LV_CL_ESPP_OUTR6_CB_TRIP ESPP Trip Status-06 (Outgoing)
1 5 3 DI S11_RIO2_LV_CL_ESPP_OUTR7_CB_ST ESPP On/ Off Status-07 (Outgoing)
1 5 4 DI S11_RIO2_LV_CL_ESPP_OUTR7_CB_TRIP ESPP Trip Status-07 (Outgoing)
1 5 5 DI S11_RIO2_LV_CL_ESPP_OUTR8_CB_ST ESPP On/ Off Status-08 (Outgoing)
1 5 6 DI S11_RIO2_LV_CL_ESPP_OUTR8_CB_TRIP ESPP Trip Status-08 (Outgoing)
1 5 7 DI S11_RIO2_LV_CL_ESPP_OUTR9_CB_ST ESPP On/ Off Status-09 (Outgoing)
1 5 8 DI S11_RIO2_LV_CL_ESPP_OUTR9_CB_TRIP ESPP Trip Status-09 (Outgoing)
1 5 9 DI S11_RIO2_LV_CL_ESPP_OUTR10_CB_ST ESPP On/ Off Status-10 (Outgoing)
1 5 10 DI S11_RIO2_LV_CL_ESPP_OUTR10_CB_TRIP ESPP Trip Status-10 (Outgoing)
1 5 11 DI S11_RIO2_LV_CL_ESPP_OUTR11_CB_ST ESPP On/ Off Status-11 (Outgoing)
1 5 12 DI S11_RIO2_LV_CL_ESPP_OUTR11_CB_TRIP ESPP Trip Status-11 (Outgoing)
1 5 13 DI S11_RIO2_LV_CL_ESPP_OUTR12_CB_ST ESPP On/ Off Status-12 (Outgoing)
1 5 14 DI S11_RIO2_LV_CL_ESPP_OUTR12_CB_TRIP ESPP Trip Status-12 (Outgoing)
1 5 15 DI S11_RIO2_LV_CL_ESPP_OUTR13_CB_ST ESPP On/ Off Status-13 (Outgoing)

1 6 0 DI S11_RIO2_LV_CL_ESPP_OUTR13_CB_TRIP ESPP Trip Status-13 (Outgoing)


1 6 1 DI S11_RIO2_LV_CL_ESPP_OUTR14_CB_ST ESPP On/ Off Status-14 (Outgoing)
1 6 2 DI S11_RIO2_LV_CL_ESPP_OUTR14_CB_TRIP ESPP Trip Status-14 (Outgoing)
1 6 3 DI S11_RIO2_LV_CL_MLP_OUTR1_CB_ST MLP On/ Off Status-01 (Outgoing)
1 6 4 DI S11_RIO2_LV_CL_MLP_OUTR1_CB_TRIP MLP Trip Status-01 (Outgoing)
1 6 5 DI S11_RIO2_LV_CL_MLP_OUTR2_CB_ST MLP On/ Off Status-02 (Outgoing)
1 6 6 DI S11_RIO2_LV_CL_MLP_OUTR2_CB_TRIP MLP Trip Status-02 (Outgoing)
1 6 7 DI S11_RIO2_LV_CL_MLP_OUTR3_CB_ST MLP On/ Off Status-03 (Outgoing)
1 6 8 DI S11_RIO2_LV_CL_MLP_OUTR3_CB_TRIP MLP Trip Status-03 (Outgoing)
1 6 9 DI S11_RIO2_LV_CL_MLP_OUTR4_CB_ST MLP On/ Off Status-04 (Outgoing)
1 6 10 DI S11_RIO2_LV_CL_MLP_OUTR4_CB_TRIP MLP Trip Status-04 (Outgoing)
1 6 11 DI S11_RIO2_LV_CL_MLP_OUTR5_CB_ST MLP On/ Off Status-05 (Outgoing)
1 6 12 DI S11_RIO2_LV_CL_MLP_OUTR5_CB_TRIP MLP Trip Status-05 (Outgoing)
1 6 13 DI S11_RIO2_LV_CL_MLP_OUTR6_CB_ST MLP On/ Off Status-06 (Outgoing)
1 6 14 DI S11_RIO2_LV_CL_MLP_OUTR6_CB_TRIP MLP Trip Status-06 (Outgoing)
1 6 15 DI S11_RIO2_LV_CL_MLP_OUTR7_CB_ST MLP On/ Off Status-07 (Outgoing)

1 7 0 DI S11_RIO2_LV_CL_MLP_OUTR7_CB_TRIP MLP Trip Status-07 (Outgoing)


1 7 1 DI S11_RIO2_LV_CL_MLP_OUTR8_CB_ST MLP On/ Off Status-08 (Outgoing)
1 7 2 DI S11_RIO2_LV_CL_MLP_OUTR8_CB_TRIP MLP Trip Status-08 (Outgoing)
1 7 3 DI S11_RIO2_LV_CL_MLP_OUTR9_CB_ST MLP On/ Off Status-09 (Outgoing)
1 7 4 DI S11_RIO2_LV_CL_MLP_OUTR9_CB_TRIP MLP Trip Status-09 (Outgoing)
1 7 5 DI S11_RIO2_LV_CL_MLP_OUTR10_CB_ST MLP On/ Off Status-10 (Outgoing)
1 7 6 DI S11_RIO2_LV_CL_MLP_OUTR10_CB_TRIP MLP Trip Status-10 (Outgoing)
1 7 7 DI S11_RIO2_LV_CL_MLP_OUTR11_CB_ST MLP On/ Off Status-11 (Outgoing)
1 7 8 DI S11_RIO2_LV_CL_MLP_OUTR11_CB_TRIP MLP Trip Status-11 (Outgoing)
1 7 9 DI S11_RIO2_LV_CL_MLP_OUTR12_CB_ST MLP On/ Off Status-12 (Outgoing)
1 7 10 DI S11_RIO2_LV_CL_MLP_OUTR12_CB_TRIP MLP Trip Status-12 (Outgoing)
1 7 11 DI S11_RIO2_LV_CL_MLP_OUTR13_CB_ST MLP On/ Off Status-13 (Outgoing)
1 7 12 DI S11_RIO2_LV_CL_MLP_OUTR13_CB_TRIP MLP Trip Status-13 (Outgoing)
1 7 13 DI S11_RIO2_LV_CL_MLP_OUTR14_CB_ST MLP On/ Off Status-14 (Outgoing)
1 7 14 DI S11_RIO2_LV_CL_MLP_OUTR14_CB_TRIP MLP Trip Status-14 (Outgoing)
1 7 15 DI S11_RIO2_LV_CL_MLP_OUTR15_CB_ST MLP On/ Off Status-15 (Outgoing)

1 8 0 DI S11_RIO2_LV_CL_MLP_OUTR15_CB_TRIP MLP Trip Status-15 (Outgoing)


1 8 1 DI S11_RIO2_LV_CL_ACPP_OUTR1_CB_ST ACPP On/ Off Status-01 (MCCB-Outgoing)
1 8 2 DI S11_RIO2_LV_CL_ACPP_OUTR1_CB_TRIP ACPP Trip Status-01 (MCCB-Outgoing)
1 8 3 DI S11_RIO2_LV_CL_ACPP_OUTR2_CB_ST ACPP On/ Off Status-02 (MCCB-Outgoing)
1 8 4 DI S11_RIO2_LV_CL_ACPP_OUTR2_CB_TRIP ACPP Trip Status-02 (MCCB-Outgoing)
1 8 5 DI S11_RIO2_LV_CL_ACPP_OUTR3_CB_ST ACPP On/ Off Status-03 (MCCB-Outgoing)
1 8 6 DI S11_RIO2_LV_CL_ACPP_OUTR3_CB_TRIP ACPP Trip Status-03 (MCCB-Outgoing)
1 8 7 DI S11_RIO2_LV_CL_ACPP_OUTR4_CB_ST ACPP On/ Off Status-04 (MCCB-Outgoing)
1 8 8 DI S11_RIO2_LV_CL_ACPP_OUTR4_CB_TRIP ACPP Trip Status-04 (MCCB-Outgoing)
1 8 9 DI S11_RIO2_LV_CL_ACPP_OUTR5_CB_ST ACPP On/ Off Status-05 (MCCB-Outgoing)
1 8 10 DI S11_RIO2_LV_CL_ACPP_OUTR5_CB_TRIP ACPP Trip Status-05 (MCCB-Outgoing)
1 8 11 DI S11_RIO2_LV_CL_ACPP_OUTR6_CB_ST ACPP On/ Off Status-06 (MCCB-Outgoing)
1 8 12 DI S11_RIO2_LV_CL_ACPP_OUTR6_CB_TRIP ACPP Trip Status-06 (MCCB-Outgoing)
1 8 13 DI S11_RIO2_LV_CL_ACPP_OUTR7_CB_ST ACPP On/ Off Status-07 (MCCB-Outgoing)
1 8 14 DI S11_RIO2_LV_CL_ACPP_OUTR7_CB_TRIP ACPP Trip Status-07 (MCCB-Outgoing)

Project : OYO Project FPSO Reciprocating Gas Compressor Page 18 of 51


Client : Technics Offshore Engineering Pte Ltd
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
FIELD TB'S
CHN TYPE

ENG UNIT
Max EU
Field

Min EU

LO-LO
SL NO

RACK

SLOT

HI-HI
CHN

LO
I/O Controller Tag Address TAG NAME DESCRIPTION Contact COMMENTS

HI
From

1 8 15 DI S11_RIO2_LV_CL_ACPP_OUTR8_CB_ST ACPP On/ Off Status-08 (MCCB-Outgoing)

1 9 0 DI S11_RIO2_LV_CL_ACPP_OUTR8_CB_TRIP ACPP Trip Status-08 (MCCB-Outgoing)


1 9 1 DI S11_RIO2_LV_CL_ACPP_OUTR1_MPCB_ST ACPP On/ Off Status-01 (MPCB-Outgoing)
1 9 2 DI S11_RIO2_LV_CL_ACPP_OUTR1_MPCB_TRIP ACPP Trip Status-01 (MPCB-Outgoing)
1 9 3 DI S11_RIO2_LV_CL_ACPP_OUTR2_MPCB_ST ACPP On/ Off Status-02 (MPCB-Outgoing)
1 9 4 DI S11_RIO2_LV_CL_ACPP_OUTR2_MPCB_TRIP ACPP Trip Status-02 (MPCB-Outgoing)
1 9 5 DI S11_RIO2_LV_CL_ACPP_OUTR3_MPCB_ST ACPP On/ Off Status-03 (MPCB-Outgoing)
1 9 6 DI S11_RIO2_LV_CL_ACPP_OUTR3_MPCB_TRIP ACPP Trip Status-03 (MPCB-Outgoing)
1 9 7 DI S11_RIO2_LV_CL_ACPP_OUTR4_MPCB_ST ACPP On/ Off Status-04 (MPCB-Outgoing)
1 9 8 DI S11_RIO2_LV_CL_ACPP_OUTR4_MPCB_TRIP ACPP Trip Status-04 (MPCB-Outgoing)
1 9 9 DI S11_RIO2_LV_CL_ACPP_OUTR5_MPCB_ST ACPP On/ Off Status-05 (MPCB-Outgoing)
1 9 10 DI S11_RIO2_LV_CL_ACPP_OUTR5_MPCB_TRIP ACPP Trip Status-05 (MPCB-Outgoing)
1 9 11 DI S11_RIO2_LV_CL_ACPP_OUTR6_MPCB_ST ACPP On/ Off Status-06 (MPCB-Outgoing)
1 9 12 DI S11_RIO2_LV_CL_ACPP_OUTR6_MPCB_TRIP ACPP Trip Status-06 (MPCB-Outgoing)
1 9 13 DI S11_RIO2_LV_CL_ACPP_OUTR7_MPCB_ST ACPP On/ Off Status-07 (MPCB-Outgoing)
1 9 14 DI S11_RIO2_LV_CL_ACPP_OUTR7_MPCB_TRIP ACPP Trip Status-07 (MPCB-Outgoing)
1 9 15 DI S11_RIO2_LV_CL_ACPP_OUTR8_MPCB_ST ACPP On/ Off Status-08 (MPCB-Outgoing)

1 10 0 DI S11_RIO2_LV_CL_ACPP_OUTR8_MPCB_TRIP ACPP Trip Status-08 (MPCB-Outgoing)


1 10 1 DI S11_RIO2_LV_CL_RAP_OUTR1_CB_ST RAP On/ Off Status-01 (Outgoing)
1 10 2 DI S11_RIO2_LV_CL_RAP_OUTR1_CB_TRIP RAP Trip Status-01 (Outgoing)
1 10 3 DI S11_RIO2_LV_CL_RAP_OUTR2_CB_ST RAP On/ Off Status-02 (Outgoing)
1 10 4 DI S11_RIO2_LV_CL_RAP_OUTR2_CB_TRIP RAP Trip Status-02 (Outgoing)
1 10 5 DI S11_RIO2_LV_CL_RAP_OUTR3_CB_ST RAP On/ Off Status-03 (Outgoing)
1 10 6 DI S11_RIO2_LV_CL_RAP_OUTR3_CB_TRIP RAP Trip Status-03 (Outgoing)
1 10 7 DI S11_RIO2_LV_CL_RAP_OUTR4_CB_ST RAP On/ Off Status-04 (Outgoing)
1 10 8 DI S11_RIO2_LV_CL_RAP_OUTR4_CB_TRIP RAP Trip Status-04 (Outgoing)
1 10 9 DI S11_RIO2_LV_CL_RAP_OUTR5_CB_ST RAP On/ Off Status-05 (Outgoing)
1 10 10 DI S11_RIO2_LV_CL_RAP_OUTR5_CB_TRIP RAP Trip Status-05 (Outgoing)
1 10 11 DI S11_RIO2_LV_CL_RAP_OUTR6_CB_ST RAP On/ Off Status-06 (Outgoing)
1 10 12 DI S11_RIO2_LV_CL_RAP_OUTR6_CB_TRIP RAP Trip Status-06 (Outgoing)
1 10 13 DI S11_RIO2_LV_CL_RAP_OUTR7_CB_ST RAP On/ Off Status-07 (Outgoing)
1 10 14 DI S11_RIO2_LV_CL_RAP_OUTR7_CB_TRIP RAP Trip Status-07 (Outgoing)
1 10 15 DI S11_RIO2_LV_CL_RAP_OUTR8_CB_ST RAP On/ Off Status-08 (Outgoing)

1 11 0 DI S11_RIO2_LV_CL_RAP_OUTR8_CB_TRIP RAP Trip Status-08 (Outgoing)


1 11 1 DI S11_RIO2_LV_CL_RAP_OUTR9_CB_ST RAP On/ Off Status-09 (Outgoing)
1 11 2 DI S11_RIO2_LV_CL_RAP_OUTR9_CB_TRIP RAP Trip Status-09 (Outgoing)
1 11 3 DI S11_RIO2_LV_CL_RAP_OUTR10_CB_ST RAP On/ Off Status-10 (Outgoing)
1 11 4 DI S11_RIO2_LV_CL_RAP_OUTR10_CB_TRIP RAP Trip Status-10 (Outgoing)
1 11 5 DI S11_RIO2_LV_CL_RAP_OUTR11_CB_ST RAP On/ Off Status-11 (Outgoing)
1 11 6 DI S11_RIO2_LV_CL_RAP_OUTR11_CB_TRIP RAP Trip Status-11 (Outgoing)
1 11 7 DI S11_RIO2_LV_CL_RAP_OUTR12_CB_ST RAP On/ Off Status-12 (Outgoing)
1 11 8 DI S11_RIO2_LV_CL_RAP_OUTR12_CB_TRIP RAP Trip Status-12 (Outgoing)
1 11 9 DI S11_RIO2_LV_CL_RAP_OUTR13_CB_ST RAP On/ Off Status-13 (Outgoing)
1 11 10 DI S11_RIO2_LV_CL_RAP_OUTR13_CB_TRIP RAP Trip Status-13 (Outgoing)
1 11 11 DI S11_RIO2_LV_CL_RAP_OUTR14_CB_ST RAP On/ Off Status-14 (Outgoing)
1 11 12 DI S11_RIO2_LV_CL_RAP_OUTR14_CB_TRIP RAP Trip Status-14 (Outgoing)
1 11 13 DI S11_RIO2_LV_CL_RAP_OUTR15_CB_ST RAP On/ Off Status-15 (Outgoing)
1 11 14 DI S11_RIO2_LV_CL_RAP_OUTR15_CB_TRIP RAP Trip Status-15 (Outgoing)
1 11 15 DI S11_RIO2_LV_CL_EACDB_OUTR1_CB_ST EACDB On/ Off Status-01 (Outgoing)

1 12 0 DI S11_RIO2_LV_CL_EACDB_OUTR1_CB_TRIP EACDB Trip Status-01 (Outgoing)


1 12 1 DI S11_RIO2_LV_CL_EACDB_OUTR2_CB_ST EACDB On/ Off Status-02 (Outgoing)
1 12 2 DI S11_RIO2_LV_CL_EACDB_OUTR2_CB_TRIP EACDB Trip Status-02 (Outgoing)
1 12 3 DI S11_RIO2_LV_CL_EACDB_OUTR3_CB_ST EACDB On/ Off Status-03 (Outgoing)
1 12 4 DI S11_RIO2_LV_CL_EACDB_OUTR3_CB_TRIP EACDB Trip Status-03 (Outgoing)
1 12 5 DI S11_RIO2_LV_CL_EACDB_OUTR4_CB_ST EACDB On/ Off Status-04 (Outgoing)
1 12 6 DI S11_RIO2_LV_CL_EACDB_OUTR4_CB_TRIP EACDB Trip Status-04 (Outgoing)
1 12 7 DI S11_RIO2_LV_CL_EPP_L/R EPP Local/remote switch status
1 12 8 DI S11_RIO2_LV_CL_EPP_ON1_INCOMR_ST EPP On Status-01 (Incoming)
1 12 9 DI S11_RIO2_LV_CL_EPP_OFF1_INCOMR_ST EPP Off Status-01 (Incoming)
1 12 10 DI S11_RIO2_LV_CL_EPP_TRIP1_INCOMR_ST EPP Trip Status-01 (Incoming)
1 12 11 DI S11_RIO2_LV_CL_EPP_ON2_INCOMR_ST EPP On Status-02 (Incoming)
1 12 12 DI S11_RIO2_LV_CL_EPP_OFF2_INCOMR_ST EPP Off Status-02 (Incoming)
1 12 13 DI S11_RIO2_LV_CL_EPP_TRIP2_INCOMR_ST EPP Trip Status-02 (Incoming)
1 12 14 DI S11_RIO2_LV_CL_EPP_ON3_INCOMR_ST EPP On Status-03 (Incoming)

Project : OYO Project FPSO Reciprocating Gas Compressor Page 19 of 51


Client : Technics Offshore Engineering Pte Ltd
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
FIELD TB'S
CHN TYPE

ENG UNIT
Max EU
Field

Min EU

LO-LO
SL NO

RACK

SLOT

HI-HI
CHN

LO
I/O Controller Tag Address TAG NAME DESCRIPTION Contact COMMENTS

HI
From

1 12 15 DI S11_RIO2_LV_CL_EPP_OFF3_INCOMR_ST EPP Off Status-03 (Incoming)

1 13 0 DI S11_RIO2_LV_CL_EPP_TRIP3_INCOMR_ST EPP Trip Status-03 (Incoming)


1 13 1 DI S11_RIO2_LV_CL_EPP_VMR_01 EPP Voltage Monitoring Relay (VMR)-01
1 13 2 DI S11_RIO2_LV_CL_EPP_VMR_02 EPP Voltage Monitoring Relay (VMR)-02
1 13 3 DI S11_RIO2_LV_CL_EPP_VMR_03 EPP Voltage Monitoring Relay (VMR)-03
1 13 4 DI S11_RIO2_LV_CL_EPP_COUPLR_ON EPP On Status-01 (Bus Coupler)
1 13 5 DI S11_RIO2_LV_CL_EPP_COUPLR_OFF EPP Off Status-01 (Bus Coupler)
1 13 6 DI S11_RIO2_LV_CL_EPP_COUPLR_TRIP EPP Trip Status-01 (Bus Coupler)
1 13 7 DI S11_RIO2_LV_CL_EPP_OUTR1_CB_ST EPP On/ Off Status-01 (Outgoing)
1 13 8 DI S11_RIO2_LV_CL_EPP_OUTR1_CB_TRIP EPP Trip Status-01 (Outgoing)
1 13 9 DI S11_RIO2_LV_CL_EPP_OUTR2_CB_ST EPP On/ Off Status-02 (Outgoing)
1 13 10 DI S11_RIO2_LV_CL_EPP_OUTR2_CB_TRIP EPP Trip Status-02 (Outgoing)
1 13 11 DI S11_RIO2_LV_CL_EPP_OUTR3_CB_ST EPP On/ Off Status-03 (Outgoing)
1 13 12 DI S11_RIO2_LV_CL_EPP_OUTR3_CB_TRIP EPP Trip Status-03 (Outgoing)
1 13 13 DI S11_RIO2_LV_CL_EPP_OUTR4_CB_ST EPP On/ Off Status-04 (Outgoing)
1 13 14 DI S11_RIO2_LV_CL_EPP_OUTR4_CB_TRIP EPP Trip Status-04 (Outgoing)
1 13 15 DI S11_RIO2_LV_CL_EPP_OUTR5_CB_ST EPP On/ Off Status-05 (Outgoing)

1 14 0 DI S11_RIO2_LV_CL_EPP_OUTR5_CB_TRIP EPP Trip Status-05 (Outgoing)


1 14 1 DI S11_RIO2_LV_CL_EPP_OUTR6_CB_ST EPP On/ Off Status-06 (Outgoing)
1 14 2 DI S11_RIO2_LV_CL_EPP_OUTR6_CB_TRIP EPP Trip Status-06 (Outgoing)
1 14 3 DI S11_RIO2_LV_CL_EPP_OUTR7_CB_ST EPP On/ Off Status-07 (Outgoing)
1 14 4 DI S11_RIO2_LV_CL_EPP_OUTR7_CB_TRIP EPP Trip Status-07 (Outgoing)
1 14 5 DI S11_RIO2_LV_CL_EPP_OUTR8_CB_ST EPP On/ Off Status-08 (Outgoing)
1 14 6 DI S11_RIO2_LV_CL_EPP_OUTR8_CB_TRIP EPP Trip Status-08 (Outgoing)
1 14 7 DI S11_RIO2_LV_CL_EPP_OUTR9_CB_ST EPP On/ Off Status-09 (Outgoing)
1 14 8 DI S11_RIO2_LV_CL_EPP_OUTR9_CB_TRIP EPP Trip Status-09 (Outgoing)
1 14 9 DI S11_RIO2_LV_CL_EPP_OUTR10_CB_ST EPP On/ Off Status-10 (Outgoing)
1 14 10 DI S11_RIO2_LV_CL_EPP_OUTR10_CB_TRIP EPP Trip Status-10 (Outgoing)
1 14 11 DI S11_RIO2_LV_CL_EPP_OUTR11_CB_ST EPP On/ Off Status-11 (Outgoing)
1 14 12 DI S11_RIO2_LV_CL_EPP_OUTR11_CB_TRIP EPP Trip Status-11 (Outgoing)
1 14 13 DI S11_RIO2_LV_CL_EPP_OUTR12_CB_ST EPP On/ Off Status-12 (Outgoing)
1 14 14 DI S11_RIO2_LV_CL_EPP_OUTR12_CB_TRIP EPP Trip Status-12 (Outgoing)
1 14 15 DI S11_RIO2_LV_CL_EPP_OUTR13_CB_ST EPP On/ Off Status-13 (Outgoing)

1 15 0 DI S11_RIO2_LV_CL_EPP_OUTR13_CB_TRIP EPP Trip Status-13 (Outgoing)


1 15 1 DI S11_RIO2_LV_CL_EPP_OUTR14_CB_ST EPP On/ Off Status-14 (Outgoing)
1 15 2 DI S11_RIO2_LV_CL_EPP_OUTR14_CB_TRIP EPP Trip Status-14 (Outgoing)
1 15 3 DI S11_RIO2_LV_CL_EPP_OUTR15_CB_ST EPP On/ Off Status-15 (Outgoing)
1 15 4 DI S11_RIO2_LV_CL_EPP_OUTR15_CB_TRIP EPP Trip Status-15 (Outgoing)
1 15 5 DI S11_RIO2_LV_CL_EPP_OUTR16_CB_ST EPP On/ Off Status-16 (Outgoing)
1 15 6 DI S11_RIO2_LV_CL_EPP_OUTR16_CB_TRIP EPP Trip Status-16 (Outgoing)
1 15 7 DI S11_RIO2_LV_CL_EPP_OUTR17_CB_ST EPP On/ Off Status-17 (Outgoing)
1 15 8 DI S11_RIO2_LV_CL_EPP_OUTR17_CB_TRIP EPP Trip Status-17 (Outgoing)
1 15 9 DI S11_RIO2_LV_CL_EPP_OUTR18_CB_ST EPP On/ Off Status-18 (Outgoing)
1 15 10 DI S11_RIO2_LV_CL_EPP_OUTR18_CB_TRIP EPP Trip Status-18 (Outgoing)
1 15 11 DI S11_RIO2_LV_CL_EPP_OUTR19_CB_ST EPP On/ Off Status-19 (Outgoing)
1 15 12 DI S11_RIO2_LV_CL_EPP_OUTR19_CB_TRIP EPP Trip Status-19 (Outgoing)
1 15 13 DI S11_RIO2_LV_CL_EPP_OUTR20_CB_ST EPP On/ Off Status-20 (Outgoing)
1 15 14 DI S11_RIO2_LV_CL_EPP_OUTR20_CB_TRIP EPP Trip Status-20 (Outgoing)
1 15 15 DI S11_RIO2_LV_CL_EPP_OUTR21_CB_ST EPP On/ Off Status-21 (Outgoing)

1 16 0 DI S11_RIO2_LV_CL_EPP_OUTR21_CB_TRIP EPP Trip Status-21 (Outgoing)


1 16 1 DI S11_RIO2_LV_CL_EPP_OUTR22_CB_ST EPP On/ Off Status-22 (Outgoing)
1 16 2 DI S11_RIO2_LV_CL_EPP_OUTR22_CB_TRIP EPP Trip Status-22 (Outgoing)
1 16 3 DI S11_RIO2_LV_CL_EPP_OUTR23_CB_ST EPP On/ Off Status-23 (Outgoing)
1 16 4 DI S11_RIO2_LV_CL_EPP_OUTR23_CB_TRIP EPP Trip Status-23 (Outgoing)
1 16 5 DI S11_RIO2_LV_CL_EPP_OUTR24_CB_ST EPP On/ Off Status-24 (Outgoing)
1 16 6 DI S11_RIO2_LV_CL_EPP_OUTR24_CB_TRIP EPP Trip Status-24 (Outgoing)
1 16 7 DI S11_RIO2_LV_CL_EPP_OUTR25_CB_ST EPP On/ Off Status-25 (Outgoing)
1 16 8 DI S11_RIO2_LV_CL_EPP_OUTR25_CB_TRIP EPP Trip Status-25 (Outgoing)
1 16 9 DI S11_RIO2_LV_CL_MLP_ATS_HO MLP ATS MM [Handle Operated]
1 16 10 DI S11_RIO2_LV_CL_MLP_ATS_CO MLP ATS MM [Controller Operated]
1 16 11 DI S11_RIO2_LV_CL_MLP_ATS_P1_ST MLP ATS Position I Status
1 16 12 DI S11_RIO2_LV_CL_MLP_ATS_P2_ST MLP ATS Position II Status
1 16 13 DI S11_RIO2_CL_AF1_L/R Axial Flow Fan-01 MCC -Local/ Remote Mode
1 16 14 DI S11_RIO2_CL_AF1_RUN_ST Axial Flow Fan-01 Run Status

Project : OYO Project FPSO Reciprocating Gas Compressor Page 20 of 51


Client : Technics Offshore Engineering Pte Ltd
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
FIELD TB'S
CHN TYPE

ENG UNIT
Max EU
Field

Min EU

LO-LO
SL NO

RACK

SLOT

HI-HI
CHN

LO
I/O Controller Tag Address TAG NAME DESCRIPTION Contact COMMENTS

HI
From

1 16 15 DI S11_RIO2_CL_AF1_TRIP_ST Axial Flow Fan-01 Trip Status

1 17 0 DI S11_RIO2_CL_AF2_L/R Axial Flow Fan-02 MCC -Local/ Remote Mode


1 17 1 DI S11_RIO2_CL_AF2_RUN_ST Axial Flow Fan-02 Run Status
1 17 2 DI S11_RIO2_CL_AF2_TRIP_ST Axial Flow Fan-02 Trip Status
1 17 3 DI S11_RIO2_CL_AF3_L/R Axial Flow Fan-03 MCC -Local/ Remote Mode
1 17 4 DI S11_RIO2_CL_AF3_RUN_ST Axial Flow Fan-03 Run Status
1 17 5 DI S11_RIO2_CL_AF3_TRIP_ST Axial Flow Fan-03 Trip Status
1 17 6 DI S11_RIO2_CL_AF4_L/R Axial Flow Fan-04 MCC -Local/ Remote Mode
1 17 7 DI S11_RIO2_CL_AF4_RUN_ST Axial Flow Fan-04 Run Status
1 17 8 DI S11_RIO2_CL_AF4_TRIP_ST Axial Flow Fan-04 Trip Status
1 17 9 DI S11_RIO2_CL_AF5_L/R Axial Flow Fan-05 MCC -Local/ Remote Mode
1 17 10 DI S11_RIO2_CL_AF5_RUN_ST Axial Flow Fan-05 Run Status
1 17 11 DI S11_RIO2_CL_AF5_TRIP_ST Axial Flow Fan-05 Trip Status
1 17 12 DI S11_RIO2_CL_AF6_L/R Axial Flow Fan-06 MCC -Local/ Remote Mode
1 17 13 DI S11_RIO2_CL_AF6_RUN_ST Axial Flow Fan-06 Run Status
1 17 14 DI S11_RIO2_CL_AF6_TRIP_ST Axial Flow Fan-06 Trip Status
1 17 15 DI S11_RIO2_CL_AF7_L/R Axial Flow Fan-07 MCC -Local/ Remote Mode

1 18 0 DI S11_RIO2_CL_AF7_RUN_ST Axial Flow Fan-07 Run Status


1 18 1 DI S11_RIO2_CL_AF7_TRIP_ST Axial Flow Fan-07 Trip Status
1 18 2 DI S11_RIO2_CL_AF8_L/R Axial Flow Fan-08 MCC -Local/ Remote Mode
1 18 3 DI S11_RIO2_CL_AF8_RUN_ST Axial Flow Fan-08 Run Status
1 18 4 DI S11_RIO2_CL_AF8_TRIP_ST Axial Flow Fan-08 Trip Status
1 18 5 DI Spare
1 18 6 DI Spare
1 18 7 DI Spare
1 18 8 DI Spare
1 18 9 DI Spare
1 18 10 DI Spare
1 18 11 DI Spare
1 18 12 DI Spare
1 18 13 DI Spare
1 18 14 DI Spare
1 18 15 DI Spare

1 19 0 DI Spare
1 19 1 DI Spare
1 19 2 DI Spare
1 19 3 DI Spare
1 19 4 DI Spare
1 19 5 DI Spare
1 19 6 DI Spare
1 19 7 DI Spare
1 19 8 DI Spare
1 19 9 DI Spare
1 19 10 DI Spare
1 19 11 DI Spare
1 19 12 DI Spare
1 19 13 DI Spare
1 19 14 DI Spare
1 19 15 DI Spare

1 20 0 DI Spare
1 20 1 DI Spare
1 20 2 DI Spare
1 20 3 DI Spare
1 20 4 DI Spare
1 20 5 DI Spare
1 20 6 DI Spare
1 20 7 DI Spare
1 20 8 DI Spare
1 20 9 DI Spare
1 20 10 DI Spare
1 20 11 DI Spare
1 20 12 DI Spare
1 20 13 DI Spare
1 20 14 DI Spare

Project : OYO Project FPSO Reciprocating Gas Compressor Page 21 of 51


Client : Technics Offshore Engineering Pte Ltd
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
FIELD TB'S
CHN TYPE

ENG UNIT
Max EU
Field

Min EU

LO-LO
SL NO

RACK

SLOT

HI-HI
CHN

LO
I/O Controller Tag Address TAG NAME DESCRIPTION Contact COMMENTS

HI
From

1 20 15 DI Spare

1 21 0 DI Spare
1 21 1 DI Spare
1 21 2 DI Spare
1 21 3 DI Spare
1 21 4 DI Spare
1 21 5 DI Spare
1 21 6 DI Spare
1 21 7 DI Spare
1 21 8 DI Spare
1 21 9 DI Spare
1 21 10 DI Spare
1 21 11 DI Spare
1 21 12 DI Spare
1 21 13 DI Spare
1 21 14 DI Spare
1 21 15 DI Spare

1 22 0 DO S11_RIO2_CL_EPP_CB1_ON_CMD EPP Breaker - 01 ON Command (Incoming)


1 22 1 DO S11_RIO2_CL_EPP_CB1_OFF_CMD EPP Breaker - 01 OFF Command (Incoming)
1 22 2 DO S11_RIO2_CL_EPP_CB2_ON_CMD EPP Breaker - 02 ON Command (Incoming)
1 22 3 DO S11_RIO2_CL_EPP_CB2_OFF_CMD EPP Breaker - 02 OFF Command (Incoming)
1 22 4 DO S11_RIO2_CL_EPP_CB3_ON_CMD EPP Breaker - 03 ON Command (Incoming)
1 22 5 DO S11_RIO2_CL_EPP_CB3_OFF_CMD EPP Breaker - 03 OFF Command (Incoming)
1 22 6 DO S11_RIO2_CL_EPP_COUPLR_ON_CMD EPP Breaker ON Command (Bus Coupler)
1 22 7 DO S11_RIO2_CL_EPP_COUPLR_OFF_CMD EPP Breaker OFF Command (Bus Coupler)

1 23 0 DO S11_RIO2_CL_AF1_CMD Axial Flow Fan-01 Run Command


1 23 1 DO S11_RIO2_CL_AF2_CMD Axial Flow Fan-02 Run Command
1 23 2 DO S11_RIO2_CL_AF3_CMD Axial Flow Fan-03 Run Command
1 23 3 DO S11_RIO2_CL_AF4_CMD Axial Flow Fan-04 Run Command
1 23 4 DO S11_RIO2_CL_AF5_CMD Axial Flow Fan-05 Run Command
1 23 5 DO S11_RIO2_CL_AF6_CMD Axial Flow Fan-06 Run Command

Project : OYO Project FPSO Reciprocating Gas Compressor Page 22 of 51


Client : Technics Offshore Engineering Pte Ltd
FIELD TB'S
CHN TYPE
SL NO

RACK

SLOT

CHN

I/O Controller Tag Address

2 0 - - - - - -

2 1 0 DI S11_RIO2_CL_APFC1_AS
2 1 1 DI S11_RIO2_CL_APFC1_MS
2 1 2 DI S11_RIO2_CL_APFC2_AS
2 1 3 DI S11_RIO2_CL_APFC2_MS
2 1 4 DI S11_RIO2_CL_APFC1_CB1_ST
2 1 5 DI S11_RIO2_CL_APFC1_CB2_ST
2 1 6 DI S11_RIO2_CL_APFC1_CB3_ST
2 1 7 DI S11_RIO2_CL_APFC1_CB4_ST
2 1 8 DI S11_RIO2_CL_APFC1_CB5_ST
2 1 9 DI S11_RIO2_CL_APFC1_CB6_ST
2 1 10 DI S11_RIO2_CL_APFC1_CB7_ST
2 1 11 DI S11_RIO2_CL_APFC1_CB8_ST
2 1 12 DI S11_RIO2_CL_APFC1_CB9_ST
2 1 13 DI S11_RIO2_CL_APFC2_CB1_ST
2 1 14 DI S11_RIO2_CL_APFC2_CB2_ST
2 1 15 DI S11_RIO2_CL_APFC2_CB3_ST

2 2 0 DI S11_RIO2_CL_APFC2_CB4_ST
2 2 1 DI S11_RIO2_CL_APFC2_CB5_ST
2 2 2 DI S11_RIO2_CL_APFC2_CB6_ST
2 2 3 DI S11_RIO2_CL_APFC2_CB7_ST
2 2 4 DI S11_RIO2_CL_APFC2_CB8_ST
2 2 5 DI S11_RIO2_CL_APFC2_CB9_ST
2 2 6 DI S11_RIO2_LV_CL_MDB_INCOMR_1_CB_L/R
2 2 7 DI S11_RIO2_LV_CL_MDB_INCOMR_1_CB_TEST
2 2 8 DI S11_RIO2_LV_CL_MDB_INCOMR_1_CB_SERVICE
2 2 9 DI S11_RIO2_LV_CL_MDB_INCOMR_2_CB_L/R
2 2 10 DI S11_RIO2_LV_CL_MDB_INCOMR_2_CB_TEST
2 2 11 DI S11_RIO2_LV_CL_MDB_INCOMR_2_CB_SERVICE
2 2 12 DI S11_RIO2_LV_CL_MDB_INCOMR_3_CB_L/R
2 2 13 DI S11_RIO2_LV_CL_MDB_INCOMR_3_CB_TEST
2 2 14 DI S11_RIO2_LV_CL_MDB_INCOMR_3_CB_SERVICE
2 2 15 DI

2 3 0 DI S11_RIO2_LV_CL_MDB_OUTR1_CB_ST
2 3 1 DI S11_RIO2_LV_CL_MDB_OUTR1_CB_TRIP
2 3 2 DI S11_RIO2_LV_CL_MDB_OUTR2_CB_ST
2 3 3 DI S11_RIO2_LV_CL_MDB_OUTR2_CB_TRIP
2 3 4 DI S11_RIO2_LV_CL_MDB_OUTR3_CB_ST
2 3 5 DI S11_RIO2_LV_CL_MDB_OUTR3_CB_TRIP
2 3 6 DI S11_RIO2_LV_CL_MDB_OUTR4_CB_ST
2 3 7 DI S11_RIO2_LV_CL_MDB_OUTR4_CB_TRIP
2 3 8 DI S11_RIO2_LV_CL_MDB_OUTR5_CB_ST
2 3 9 DI S11_RIO2_LV_CL_MDB_OUTR5_CB_TRIP
2 3 10 DI S11_RIO2_LV_CL_MDB_OUTR6_CB_ST
2 3 11 DI S11_RIO2_LV_CL_MDB_OUTR6_CB_TRIP
2 3 12 DI S11_RIO2_LV_CL_MDB_OUTR7_CB_ST
2 3 13 DI S11_RIO2_LV_CL_MDB_OUTR7_CB_TRIP
2 3 14 DI S11_RIO2_LV_CL_MDB_OUTR8_CB_ST
2 3 15 DI S11_RIO2_LV_CL_MDB_OUTR8_CB_TRIP
S11_RIO2_LV_CL_MDB_OUTR9_CB_ST
2 4 0 DI S11_RIO2_LV_CL_MDB_OUTR9_CB_TRIP
2 4 1 DI S11_RIO2_LV_CL_MDB_OUTR10_CB_ST
2 4 2 DI S11_RIO2_LV_CL_MDB_OUTR10_CB_TRIP
2 4 3 DI S11_RIO2_LV_CL_MDB_OUTR11_CB_ST
2 4 4 DI S11_RIO2_LV_CL_MDB_OUTR11_CB_TRIP
2 4 5 DI S11_RIO2_LV_CL_MDB_OUTR12_CB_ST
2 4 6 DI S11_RIO2_LV_CL_MDB_OUTR12_CB_TRIP
2 4 7 DI S11_RIO2_LV_CL_MDB_OUTR13_CB_ST
2 4 8 DI S11_RIO2_LV_CL_MDB_OUTR13_CB_TRIP
2 4 9 DI S11_RIO2_LV_CL_MDB_OUTR14_CB_ST
2 4 10 DI S11_RIO2_LV_CL_MDB_OUTR14_CB_TRIP
2 4 11 DI S11_RIO2_LV_CL_MDB_OUTR15_CB_ST
2 4 12 DI S11_RIO2_LV_CL_MDB_OUTR15_CB_TRIP
2 4 13 DI S11_RIO2_LV_CL_MDB_OUTR16_CB_ST
2 4 14 DI S11_RIO2_LV_CL_MDB_OUTR16_CB_TRIP
2 4 15 DI

2 5 0 DI S11_RIO2_CL_APFC3_MS
2 5 1 DI S11_RIO2_CL_APFC4_AS
2 5 2 DI S11_RIO2_CL_APFC4_MS
2 5 3 DI S11_RIO2_CL_APFC3_CB1_ST
2 5 4 DI S11_RIO2_CL_APFC3_CB2_ST
2 5 5 DI S11_RIO2_CL_APFC3_CB3_ST
2 5 6 DI S11_RIO2_CL_APFC3_CB4_ST
2 5 7 DI S11_RIO2_CL_APFC3_CB5_ST
2 5 8 DI S11_RIO2_CL_APFC3_CB6_ST
2 5 9 DI S11_RIO2_CL_APFC3_CB7_ST
2 5 10 DI S11_RIO2_CL_APFC3_CB8_ST
2 5 11 DI S11_RIO2_CL_APFC3_CB9_ST
2 5 12 DI S11_RIO2_CL_APFC3_CB10_ST
2 5 13 DI S11_RIO2_CL_APFC3_CB11_ST
2 5 14 DI S11_RIO2_CL_APFC3_CB12_ST
2 5 15 DI S11_RIO2_CL_APFC4_CB1_ST

2 6 0 DI S11_RIO2_CL_APFC4_CB2_ST
2 6 1 DI S11_RIO2_CL_APFC4_CB3_ST
2 6 2 DI S11_RIO2_CL_APFC4_CB4_ST
2 6 3 DI S11_RIO2_CL_APFC4_CB5_ST
2 6 4 DI S11_RIO2_CL_APFC4_CB6_ST
2 6 5 DI S11_RIO2_CL_APFC4_CB7_ST
2 6 6 DI S11_RIO2_CL_APFC4_CB8_ST
2 6 7 DI S11_RIO2_CL_APFC4_CB9_ST
2 6 8 DI S11_RIO2_CL_APFC4_CB10_ST
2 6 9 DI S11_RIO2_CL_APFC4_CB11_ST
2 6 10 DI S11_RIO2_CL_APFC4_CB12_ST
2 6 11 DI S11_RIO2_LV_CL_WPP_INCOMR_CB_ST
2 6 12 DI S11_RIO2_LV_CL_WPP_INCOMR_CB_TRIP
2 6 13 DI S11_RIO2_LV_CL_WPP_OUTR1_CB_ST
2 6 14 DI S11_RIO2_LV_CL_WPP_OUTR1_CB_TRIP
2 6 15 DI S11_RIO2_LV_CL_WPP_OUTR2_CB_ST

2 7 0 DI S11_RIO2_LV_CL_WPP_OUTR2_CB_TRIP
2 7 1 DI S11_RIO2_LV_CL_WPP_OUTR3_CB_ST
2 7 2 DI S11_RIO2_LV_CL_WPP_OUTR3_CB_TRIP
2 7 3 DI S11_RIO2_LV_CL_WPP_OUTR4_CB_ST
2 7 4 DI S11_RIO2_LV_CL_WPP_OUTR4_CB_TRIP
2 7 5 DI S11_RIO2_LV_CL_WPP_OUTR5_CB_ST
2 7 6 DI S11_RIO2_LV_CL_WPP_OUTR5_CB_TRIP
2 7 7 DI S11_RIO2_LV_CL_WPP_OUTR6_CB_ST
2 7 8 DI S11_RIO2_LV_CL_WPP_OUTR6_CB_TRIP
2 7 9 DI S11_RIO2_LV_CL_WPP_OUTR7_CB_ST
2 7 10 DI S11_RIO2_LV_CL_WPP_OUTR7_CB_TRIP
2 7 11 DI S11_RIO2_LV_CL_WPP_OUTR8_CB_ST
2 7 12 DI S11_RIO2_LV_CL_WPP_OUTR8_CB_TRIP
2 7 13 DI S11_RIO2_LV_CL_WPP_OUTR9_CB_ST
2 7 14 DI S11_RIO2_LV_CL_WPP_OUTR9_CB_TRIP
2 7 15 DI S11_RIO2_LV_CL_WPP_ATS_HO

2 8 0 DI S11_RIO2_LV_CL_WPP_ATS_CO
2 8 1 DI S11_RIO2_LV_CL_WPP_ATS_P1_ST
2 8 2 DI S11_RIO2_LV_CL_WPP_ATS_P2_ST
2 8 3 DI S11_RIO2_CL_WPP_VF1_OP_L/R
2 8 4 DI S11_RIO2_CL_WPP_VF1_RUN_ST
2 8 5 DI S11_RIO2_CL_WPP_VF1_CB_TRIP
2 8 6 DI S11_RIO2_CL_WPP_VF2_OP_L/R
2 8 7 DI S11_RIO2_CL_WPP_VF2_RUN_ST
2 8 8 DI S11_RIO2_CL_WPP_VF2_CB_TRIP
2 8 9 DI S11_RIO2_DSP1_RUN_ST
2 8 10 DI S11_RIO2_DSP1_CB_TRIP
2 8 11 DI S11_RIO2_DSP2_RUN_ST
2 8 12 DI S11_RIO2_DSP2_CB_TRIP
2 8 13 DI S11_RIO2_HPP1_L/R
2 8 14 DI S11_RIO2_HPP1_RUN_ST
2 8 15 DI S11_RIO2_HPP1_TRIP_ST

2 9 0 DI S11_RIO2_HPP2_L/R
2 9 1 DI S11_RIO2_HPP2_RUN_ST
2 9 2 DI S11_RIO2_HPP2_TRIP_ST
2 9 3 DI S11_RIO2_LDB_GL_1/RA_01_ON/OFF_ST
2 9 4 DI S11_RIO2_LDB_GL_1/RA_02_ON/OFF_ST
2 9 5 DI S11_RIO2_LDB_GL_1/RA_03_ON/OFF_ST
2 9 6 DI S11_RIO2_LDB_GL_1/RA_04_ON/OFF_ST
2 9 7 DI S11_RIO2_LDB_GL_1/RA_05_ON/OFF_ST
2 9 8 DI S11_RIO2_LDB_GL_1/RA_06_ON/OFF_ST
2 9 9 DI S11_RIO2_LDB_GL_1/RB_01_ON/OFF_ST
2 9 10 DI S11_RIO2_LDB_GL_1/RB_02_ON/OFF_ST
2 9 11 DI S11_RIO2_LDB_GL_1/RB_03_ON/OFF_ST
2 9 12 DI S11_RIO2_LDB_GL_1/RB_04_ON/OFF_ST
2 9 13 DI S11_RIO2_LDB_GL_1/RB_05_ON/OFF_ST
2 9 14 DI S11_RIO2_LDB_GL_1/RB_06_ON/OFF_ST
2 9 15 DI

2 10 0 DI
2 10 1 DI
2 10 2 DI
2 10 3 DI
2 10 4 DI
2 10 5 DI
2 10 6 DI
2 10 7 DI
2 10 8 DI
2 10 9 DI
2 10 10 DI
2 10 11 DI
2 10 12 DI
2 10 13 DI
2 10 14 DI
2 10 15 DI

2 11 0 DI
2 11 1 DI
2 11 2 DI
2 11 3 DI
2 11 4 DI
2 11 5 DI
2 11 6 DI
2 11 7 DI
2 11 8 DI
2 11 9 DI
2 11 10 DI
2 11 11 DI
2 11 12 DI
2 11 13 DI
2 11 14 DI
2 11 15 DI

2 12 0 DI
2 12 1 DI
2 12 2 DI
2 12 3 DI
2 12 4 DI
2 12 5 DI
2 12 6 DI
2 12 7 DI
2 12 8 DI
2 12 9 DI
2 12 10 DI
2 12 11 DI
2 12 12 DI
2 12 13 DI
2 12 14 DI
2 12 15 DI

2 13 0 DO S11_RIO2_CL_WPP_VF1_RUN_CMD
2 13 1 DO S11_RIO2_CL_WPP_VF2_RUN_CMD
2 13 2 DO S11_RIO3_BL_HPP1_RUN_CMD
2 13 3 DO S11_RIO3_BL_HPP2_RUN_CMD
2 13 4 DO S11_RIO2_LDB_GL_1/RA_01_ON/OFF_ST
2 13 5 DO S11_RIO2_LDB_GL_1/RA_02_ON/OFF_ST
2 13 6 DO S11_RIO2_LDB_GL_1/RA_03_ON/OFF_ST
2 13 7 DO S11_RIO2_LDB_GL_1/RA_04_ON/OFF_ST

2 14 0 DO S11_RIO2_LDB_GL_1/RA_05_ON/OFF_ST
2 14 1 DO S11_RIO2_LDB_GL_1/RA_06_ON/OFF_ST
2 14 2 DO S11_RIO2_LDB_GL_1/RB_01_ON/OFF_ST
2 14 3 DO S11_RIO2_LDB_GL_1/RB_02_ON/OFF_ST
2 14 4 DO S11_RIO2_LDB_GL_1/RB_03_ON/OFF_ST
2 14 5 DO S11_RIO2_LDB_GL_1/RB_04_ON/OFF_ST
2 14 6 DO S11_RIO2_LDB_GL_1/RB_05_ON/OFF_ST
2 14 7 DO S11_RIO2_LDB_GL_1/RB_06_ON/OFF_ST

2 15 0 DO
2 15 1 DO
2 15 2 DO
2 15 3 DO
2 15 4 DO
2 15 5 DO
2 15 6 DO
2 15 7 DO

2 16 0 F-DI S11_RIO2_CL_APFC1_CB1_ST
2 16 1 F-DI S11_RIO2_CL_APFC1_CB2_ST
2 16 2 F-DI S11_RIO2_CL_APFC1_CB3_ST
2 16 3 F-DI S11_RIO2_CL_APFC1_CB4_ST
2 16 4 F-DI S11_RIO2_CL_APFC1_CB5_ST
2 16 5 F-DI S11_RIO2_CL_APFC1_CB6_ST
2 16 6 F-DI S11_RIO2_CL_APFC1_CB7_ST
2 16 7 F-DI S11_RIO2_CL_APFC1_CB8_ST

2 17 0 F-DI S11_RIO2_CL_APFC1_CB9_ST
2 17 1 F-DI S11_RIO2_CL_APFC2_CB1_ST
2 17 2 F-DI S11_RIO2_CL_APFC2_CB2_ST
2 17 3 F-DI S11_RIO2_CL_APFC2_CB3_ST
2 17 4 F-DI S11_RIO2_CL_APFC2_CB4_ST
2 17 5 F-DI S11_RIO2_CL_APFC2_CB5_ST
2 17 6 F-DI S11_RIO2_CL_APFC2_CB6_ST
2 17 7 F-DI S11_RIO2_CL_APFC2_CB7_ST
2 18 0 F-DI S11_RIO2_CL_APFC2_CB8_ST
2 18 1 F-DI S11_RIO2_CL_APFC2_CB9_ST
2 18 2 F-DI S11_RIO2_LV_CL_MDB_INCOMR_1_CB_ON_ST
2 18 3 F-DI S11_RIO2_LV_CL_MDB_INCOMR_1_CB_OFF_ST
2 18 4 F-DI S11_RIO2_LV_CL_MDB_INCOMR_1_HT_ CB_TRIP_ST
2 18 5 F-DI S11_RIO2_LV_CL_MDB_INCOMR_1_CB_TRIP_ST
2 18 6 F-DI S11_RIO2_LV_CL_MDB_INCOMR_1_V_CB_TRIP_ST
2 18 7 F-DI S11_RIO2_LV_CL_MDB_INCOMR_2_CB_ON_ST

2 19 0 F-DI S11_RIO2_LV_CL_MDB_INCOMR_2_CB_OFF_ST
2 19 1 F-DI S11_RIO2_LV_CL_MDB_INCOMR_2_HT_ CB_TRIP_ST
2 19 2 F-DI S11_RIO2_LV_CL_MDB_INCOMR_2_CB_TRIP_ST
2 19 3 F-DI S11_RIO2_LV_CL_MDB_INCOMR_2_V_CB_TRIP_ST
2 19 4 F-DI S11_RIO2_LV_CL_MDB_INCOMR_3_CB_ON_ST
2 19 5 F-DI S11_RIO2_LV_CL_MDB_INCOMR_3_CB_OFF_ST
2 19 6 F-DI S11_RIO2_LV_CL_MDB_INCOMR_3_HT_ CB_TRIP_ST
2 19 7 F-DI S11_RIO2_LV_CL_MDB_INCOMR_3_CB_TRIP_ST

2 20 0 F-DI S11_RIO2_LV_CL_MDB_INCOMR_3_V_CB_TRIP_ST
2 20 1 F-DI S11_RIO2_CL_APFC3_CB1_TRIP
2 20 2 F-DI S11_RIO2_CL_APFC3_CB2_TRIP
2 20 3 F-DI S11_RIO2_CL_APFC3_CB3_TRIP
2 20 4 F-DI S11_RIO2_CL_APFC3_CB4_TRIP
2 20 5 F-DI S11_RIO2_CL_APFC3_CB5_TRIP
2 20 6 F-DI S11_RIO2_CL_APFC3_CB6_TRIP
2 20 7 F-DI S11_RIO2_CL_APFC3_CB7_TRIP

2 21 0 F-DI S11_RIO2_CL_APFC3_CB8_TRIP
2 21 1 F-DI S11_RIO2_CL_APFC3_CB9_TRIP
2 21 2 F-DI S11_RIO2_CL_APFC3_CB10_TRIP
2 21 3 F-DI S11_RIO2_CL_APFC3_CB11_TRIP
2 21 4 F-DI S11_RIO2_CL_APFC3_CB12_TRIP
2 21 5 F-DI S11_RIO2_CL_APFC4_CB1_TRIP
2 21 6 F-DI S11_RIO2_CL_APFC4_CB2_TRIP
2 21 7 F-DI S11_RIO2_CL_APFC4_CB3_TRIP

2 22 0 F-DI S11_RIO2_CL_APFC4_CB4_TRIP
2 22 1 F-DI S11_RIO2_CL_APFC4_CB5_TRIP
2 22 2 F-DI S11_RIO2_CL_APFC4_CB6_TRIP
2 22 3 F-DI S11_RIO2_CL_APFC4_CB7_TRIP
2 22 4 F-DI S11_RIO2_CL_APFC4_CB8_TRIP
2 22 5 F-DI S11_RIO2_CL_APFC4_CB9_TRIP
2 22 6 F-DI S11_RIO2_CL_APFC4_CB10_TRIP
2 22 7 F-DI S11_RIO2_CL_APFC4_CB11_TRIP

2 23 0 F-DI S11_RIO2_CL_APFC3_CB12_TRIP
2 23 1 F-DI
2 23 2 F-DI
2 23 3 F-DI
2 23 4 F-DI
2 23 5 F-DI
2 23 6 F-DI
2 23 7 F-DI
2 24 0 F-DO S11_RIO2_LV_CL_MDB_INCOMR_1_CB_CMD
2 24 1 F-DO S11_RIO2_LV_CL_MDB_INCOMR_2_CB_CMD
2 24 2 F-DO S11_RIO2_LV_CL_MDB_INCOMR_3_CB_CMD
2 24 3 F-DO
2 24 4 F-DO
2 24 5 F-DO
2 24 6 F-DO
2 24 7 F-DO

2 25 0 F-AI
2 25 1 F-AI
2 25 2 F-AI
2 25 3 F-AI

2 26 0 AQ
2 26 1 AQ
2 26 2 AQ
2 26 3 AQ

2 27 0 AQ
2 27 1 AQ
2 27 2 AQ
2 27 3 AQ

2 28 CM Ptp

2 29 CM Ptp

2 30 CM Ptp
Field
TAG NAME DESCRIPTION Contact
From

Interface Module

APFC-01 Auto Status


APFC-01 Manual Status
APFC-02 Auto Status
APFC-02 Manual Status
APFC-01 Breaker-01 On/ Off Status
APFC-01 Breaker-02 On/ Off Status
APFC-01 Breaker-03 On/ Off Status
APFC-01 Breaker-04 On/ Off Status
APFC-01 Breaker-05 On/ Off Status
APFC-01 Breaker-06 On/ Off Status
APFC-01 Breaker-07 On/ Off Status
APFC-01 Breaker-08 On/ Off Status
APFC-01 Breaker-09 On/ Off Status
APFC-02 Breaker-01 On/ Off Status
APFC-02 Breaker-02 On/ Off Status
APFC-02 Breaker-03 On/ Off Status

APFC-02 Breaker-04 On/ Off Status


APFC-02 Breaker-05 On/ Off Status
APFC-02 Breaker-06 On/ Off Status
APFC-02 Breaker-07 On/ Off Status
APFC-02 Breaker-08 On/ Off Status
APFC-02 Breaker-09 On/ Off Status
ACB-01 Breaker - REMOTE mode status (MDB-Incoming)
ACB-01 Breaker TEST position status (MDB-Incoming)
ACB-01 Breaker Service status (MDB-Incoming)
ACB-02 Breaker - REMOTE mode status (MDB-Incoming)
ACB-02 Breaker TEST position status (MDB-Incoming)
ACB-02 Breaker Service status (MDB-Incoming)
ACB-03 Breaker - REMOTE mode status (MDB-Incoming)
ACB-03 Breaker TEST position status (MDB-Incoming)
ACB-03 Breaker Service status (MDB-Incoming)
MDB On/ Off Status-01 (Outgoing)

MDB Trip Status-01 (Outgoing)


MDB On/ Off Status-02 (Outgoing)
MDB Trip Status-02 (Outgoing)
MDB On/ Off Status-03 (Outgoing)
MDB Trip Status-03 (Outgoing)
MDB On/ Off Status-04 (Outgoing)
MDB Trip Status-04 (Outgoing)
MDB On/ Off Status-05 (Outgoing)
MDB Trip Status-05 (Outgoing)
MDB On/ Off Status-06 (Outgoing)
MDB Trip Status-06 (Outgoing)
MDB On/ Off Status-07 (Outgoing)
MDB Trip Status-07 (Outgoing)
MDB On/ Off Status-08 (Outgoing)
MDB Trip Status-08 (Outgoing)
MDB On/ Off Status-09 (Outgoing)

MDB Trip Status-09 (Outgoing)


MDB On/ Off Status-10 (Outgoing)
MDB Trip Status-10 (Outgoing)
MDB On/ Off Status-11 (Outgoing)
MDB Trip Status-11 (Outgoing)
MDB On/ Off Status-12 (Outgoing)
MDB Trip Status-12 (Outgoing)
MDB On/ Off Status-13 (Outgoing)
MDB Trip Status-13 (Outgoing)
MDB On/ Off Status-14 (Outgoing)
MDB Trip Status-14 (Outgoing)
MDB On/ Off Status-15 (Outgoing)
MDB Trip Status-15 (Outgoing)
MDB On/ Off Status-16 (Outgoing)
MDB Trip Status-16 (Outgoing)
APFC-03 Auto Status

APFC-03 Manual Status


APFC-04 Auto Status
APFC-04 Manual Status
APFC-03 Breaker-01 On/ Off Status
APFC-03 Breaker-02 On/ Off Status
APFC-03 Breaker-03 On/ Off Status
APFC-03 Breaker-04 On/ Off Status
APFC-03 Breaker-05 On/ Off Status
APFC-03 Breaker-06 On/ Off Status
APFC-03 Breaker-07 On/ Off Status
APFC-03 Breaker-08 On/ Off Status
APFC-03 Breaker-09 On/ Off Status
APFC-03 Breaker-10 On/ Off Status
APFC-03 Breaker-11 On/ Off Status
APFC-03 Breaker-12 On/ Off Status
APFC-04 Breaker-01 On/ Off Status

APFC-04 Breaker-02 On/ Off Status


APFC-04 Breaker-03 On/ Off Status
APFC-04 Breaker-04 On/ Off Status
APFC-04 Breaker-05 On/ Off Status
APFC-04 Breaker-06 On/ Off Status
APFC-04 Breaker-07 On/ Off Status
APFC-04 Breaker-08 On/ Off Status
APFC-04 Breaker-09 On/ Off Status
APFC-04 Breaker-10 On/ Off Status
APFC-04 Breaker-11 On/ Off Status
APFC-04 Breaker-12 On/ Off Status
WPP On/ Off Status (Incoming)
WPP Trip Status (Incoming)
WPP On/ Off Status-01 (Outgoing)
WPP Trip Status-01 (Outgoing)
WPP On/ Off Status-02 (Outgoing)

WPP Trip Status-02 (Outgoing)


WPP On/ Off Status-03 (Outgoing)
WPP Trip Status-03 (Outgoing)
WPP On/ Off Status-04 (Outgoing)
WPP Trip Status-04 (Outgoing)
WPP On/ Off Status-05 (Outgoing)
WPP Trip Status-05 (Outgoing)
WPP On/ Off Status-06 (Outgoing)
WPP Trip Status-06 (Outgoing)
WPP On/ Off Status-07 (Outgoing)
WPP Trip Status-07 (Outgoing)
WPP On/ Off Status-08 (Outgoing)
WPP Trip Status-08 (Outgoing)
WPP On/ Off Status-09 (Outgoing)
WPP Trip Status-09 (Outgoing)
WPP ATS MM [Handle Operated]

WPP ATS MM [Controller Operated]


WPP ATS Position I Status
WPP ATS Position II Status
WPP Ventilation Fan-01 MCC- Local/Remote mode
WPP Ventilation Fan-01 Run Status
WPP Ventilation Fan-01 Trip Status
WPP Ventilation Fan-02 MCC- Local/Remote mode
WPP Ventilation Fan-02 Run Status
WPP Ventilation Fan-02 Trip Status
Drainage Sump Pump-01 Run Status
Drainage Sump Pump-01 Trip Condition Status
Drainage Sump Pump-02 Run Status
Drainage Sump Pump-02 Trip Condition Status
Hydro-pneumatic Pump-01 MCC - Remote/ Local
Hydro-pneumatic Pump-01 - Run Status
Hydro-pneumatic Pump-01 - Trip Status

Hydro-pneumatic Pump-02 MCC - Remote/ Local


Hydro-pneumatic Pump-02 - Run Status
Hydro-pneumatic Pump-02 - Trip Status
LDB On/ Off Status LDB 1/RA-01
LDB On/ Off Status LDB 1/RA-02
LDB On/ Off Status LDB 1/RA-03
LDB On/ Off Status LDB 1/RA-04
LDB On/ Off Status LDB 1/RA-05
LDB On/ Off Status LDB 1/RA-06
LDB On/ Off Status LDB 1/RB-01
LDB On/ Off Status LDB 1/RB-02
LDB On/ Off Status LDB 1/RB-03
LDB On/ Off Status LDB 1/RB-04
LDB On/ Off Status LDB 1/RB-05
LDB On/ Off Status LDB 1/RB-06
Spare

Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare

Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare

Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare

WPP Ventilation Fan-01 Run Command


WPP Ventilation Fan-02 Run Command
Hydro-Pneumatic Pump -01 On/ Off Command
Hydro-Pneumatic Pump -02 On/ Off Command
LDB On/ Off Status LDB 1/RA-01
LDB On/ Off Status LDB 1/RA-02
LDB On/ Off Status LDB 1/RA-03
LDB On/ Off Status LDB 1/RA-04

LDB On/ Off Status LDB 1/RA-05


LDB On/ Off Status LDB 1/RA-06
LDB On/ Off Status LDB 1/RB-01
LDB On/ Off Status LDB 1/RB-02
LDB On/ Off Status LDB 1/RB-03
LDB On/ Off Status LDB 1/RB-04
LDB On/ Off Status LDB 1/RB-05
LDB On/ Off Status LDB 1/RB-06

Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare

APFC-01 Breaker-01 Trip Status


APFC-01 Breaker-02 Trip Status
APFC-01 Breaker-03 Trip Status
APFC-01 Breaker-04 Trip Status
APFC-01 Breaker-05 Trip Status
APFC-01 Breaker-06 Trip Status
APFC-01 Breaker-07 Trip Status
APFC-01 Breaker-08 Trip Status

APFC-01 Breaker-09 Trip Status


APFC-02 Breaker-01 Trip Status
APFC-02 Breaker-02 Trip Status
APFC-02 Breaker-03 Trip Status
APFC-02 Breaker-04 Trip Status
APFC-02 Breaker-05 Trip Status
APFC-02 Breaker-06 Trip Status
APFC-02 Breaker-07 Trip Status
APFC-02 Breaker-08 Trip Status
APFC-02 Breaker-09 Trip Status
ACB Breaker-01 ON status (MDB-Incoming)
ACB Breaker-01 OFF status (MDB-Incoming)
ACB HT Breaker -01 TRIP status (MDB-Incoming)
ACB Breaker -01 TRIP status (MDB-Incoming)
ACB Breaker -01 V TRIP status (MDB-Incoming)
ACB Breaker-02 ON status (MDB-Incoming)

ACB Breaker-02 OFF status (MDB-Incoming)


ACB HT Breaker -02 TRIP status (MDB-Incoming)
ACB Breaker -02 TRIP status (MDB-Incoming)
ACB Breaker -02 V TRIP status (MDB-Incoming)
ACB Breaker-03 ON status (MDB-Incoming)
ACB Breaker-03 OFF status (MDB-Incoming)
ACB HT Breaker -03 TRIP status (MDB-Incoming)
ACB Breaker -03 TRIP status (MDB-Incoming)

ACB Breaker -03 V TRIP status (MDB-Incoming)


APFC-03 Breaker-01 Trip Status
APFC-03 Breaker-02 Trip Status
APFC-03 Breaker-03 Trip Status
APFC-03 Breaker-04 Trip Status
APFC-03 Breaker-05 Trip Status
APFC-03 Breaker-06 Trip Status
APFC-03 Breaker-07 Trip Status

APFC-03 Breaker-08 Trip Status


APFC-03 Breaker-09 Trip Status
APFC-03 Breaker-10 Trip Status
APFC-03 Breaker-11 Trip Status
APFC-03 Breaker-12 Trip Status
APFC-04 Breaker-01 Trip Status
APFC-04 Breaker-02 Trip Status
APFC-04 Breaker-03 Trip Status

APFC-04 Breaker-04 Trip Status


APFC-04 Breaker-05 Trip Status
APFC-04 Breaker-06 Trip Status
APFC-04 Breaker-07 Trip Status
APFC-04 Breaker-08 Trip Status
APFC-04 Breaker-09 Trip Status
APFC-04 Breaker-10 Trip Status
APFC-04 Breaker-11 Trip Status

APFC-04 Breaker-12 Trip Status


Spare
Spare
Spare
Spare
Spare
Spare
Spare
ACB Breaker -01 On/Off Command (MDB-Incoming)
ACB Breaker -02 On/Off Command (MDB-Incoming)
ACB Breaker -03 On/Off Command (MDB-Incoming)
Spare
Spare
Spare
Spare
Spare

Spare
Spare
Spare
Spare

Spare
Spare
Spare
Spare

Spare
Spare
Spare
Spare
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
ENG UNIT
Max EU
Min EU

LO-LO

HI-HI
LO

HI
COMMENTS
Gissmatic Doc No :
Rev :
Prominent Doc. No :
Client Doc No :
Date :
Filename :

CLOSE (V/mA)
OPEN (V/mA)
FIELD TB'S
CHN TYPE

ENG UNIT
Max EU
Field

Min EU

LO-LO
SL NO

RACK

SLOT

HI-HI
CHN

LO
I/O Controller Tag Address TAG NAME DESCRIPTION Contact COMMENTS

HI
From

1 0 - - - - - - Interface Module

1 1 0 DI S11_RIO3_JKY_FP_CB_ST Jockey Pump - Run Status


1 1 1 DI S11_RIO3_LV_GL_DG-AMF_INCOMR_1_CB_L/R ACB REMOTE mode status (DG-AMF Incoming)
1 1 2 DI S11_RIO3_LV_GL_DG-AMF_INCOMR_1_CB_TEST ACB Breaker TEST position status (DG-AMF Incoming)
1 1 3 DI S11_RIO3_LV_GL_DG-AMF_INCOMR_1_CB_SERVICE ACB Breaker Service status (DG-AMF Incoming)
1 1 4 DI S11_RIO3_LV_GL_DG-AMF_OUTR1_CB_ST DG-AMF On/ Off Status-01 (Outgoing)
1 1 5 DI S11_RIO3_LV_GL_DG-AMF_OUTR1_CB_TRIP DG-AMF Trip Status-01 (Outgoing)
1 1 6 DI S11_RIO3_LV_GL_DG-AMF_OUTR2_CB_ST DG-AMF On/ Off Status-02 (Outgoing)
1 1 7 DI S11_RIO3_LV_GL_DG-AMF_OUTR2_CB_TRIP DG-AMF Trip Status-02 (Outgoing)
1 1 8 DI S11_RIO3_LV_GL_DG-AMF_OUTR3_CB_ST DG-AMF On/ Off Status-03 (Outgoing)
1 1 9 DI S11_RIO3_LV_GL_DG-AMF_OUTR3_CB_TRIP DG-AMF Trip Status-03 (Outgoing)
1 1 10 DI S11_RIO3_LV_GL_FPP_OUTR1_CB_ST FPP On/ Off Status-01 (Outgoing)
1 1 11 DI S11_RIO3_LV_GL_FPP_OUTR1_CB_TRIP FPP Trip Status-01 (Outgoing)
1 1 12 DI S11_RIO3_LV_GL_FPP_OUTR2_CB_ST FPP On/ Off Status-02 (Outgoing)
1 1 13 DI S11_RIO3_LV_GL_FPP_OUTR2_CB_TRIP FPP Trip Status-02 (Outgoing)
1 1 14 DI S11_RIO3_LV_GL_FPP_OUTR3_CB_ST FPP On/ Off Status-03 (Outgoing)
1 1 15 DI S11_RIO3_LV_GL_FPP_OUTR3_CB_TRIP FPP Trip Status-03 (Outgoing)

1 2 0 DI S11_RIO3_LV_GL_FPP_OUTR4_CB_ST FPP On/ Off Status-04 (Outgoing)


1 2 1 DI S11_RIO3_LV_GL_FPP_OUTR4_CB_TRIP FPP Trip Status-04 (Outgoing)
1 2 2 DI S11_RIO3_LV_GL_FPP_OUTR5_CB_ST FPP On/ Off Status-05 (Outgoing)
1 2 3 DI S11_RIO3_LV_GL_FPP_OUTR5_CB_TRIP FPP Trip Status-05 (Outgoing)
1 2 4 DI S11_RIO3_LV_GL_FPP_ATS_HO FPP ATS MM [Handle Operated]
1 2 5 DI S11_RIO3_LV_GL_FPP_ATS_CO FPP ATS MM [Controller Operated]
1 2 6 DI S11_RIO3_LV_GL_FPP_ATS_P1_ST FPP ATS Position I Status
1 2 7 DI S11_RIO3_LV_GL_FPP_ATS_P2_ST FPP ATS Position II Status
1 2 8 DI S11_RIO3_PRL_WT_LVL_HI Raw and Portable Water Tank Level High
1 2 9 DI S11_RIO3_PRL_WT_LVL_LO Raw and Portable Water Tank Level Low
1 2 10 DI S11_RIO3_STP_1_ON/OFF_ST STP-01 Air Blower On/ Off Status
1 2 11 DI S11_RIO3_STP_1_OL_TRIP STP-01 Overload Trip Status
1 2 12 DI S11_RIO3_STP_1_L/R_ST STP-01 Control Panel Local-Off-Remote Selector
1 2 13 DI S11_RIO3_STP_2_ON/OFF_ST STP-02 Air Blower On/ Off Status
1 2 14 DI S11_RIO3_STP_2_OL_TRIP STP-02 Overload Trip Status
1 2 15 DI S11_RIO3_STP_2_L/R_ST STP-02 Control Panel Local-Off-Remote Selector

1 3 0 DI S11_RIO3_LDB_GL_3/R_01_ON/OFF_ST LDB On/ Off Status LDB 3/R-01


1 3 1 DI S11_RIO3_LDB_GL_3/R_02_ON/OFF_ST LDB On/ Off Status LDB 3/R-02
1 3 2 DI S11_RIO3_LDB_GL_3/R_03_ON/OFF_ST LDB On/ Off Status LDB 3/R-03
1 3 3 DI S11_RIO3_LDB_GL_3/R_04_ON/OFF_ST LDB On/ Off Status LDB 3/R-04
1 3 4 DI Spare
1 3 5 DI Spare
1 3 6 DI Spare
1 3 7 DI Spare
1 3 8 DI Spare
1 3 9 DI Spare
1 3 10 DI Spare
1 3 11 DI Spare
1 3 12 DI Spare
1 3 13 DI Spare
1 3 14 DI Spare

Project : OYO Project FPSO Reciprocating Gas Compressor Page 51 of 51