You are on page 1of 7

HYBRID POLYMER LINE POST CATALOG

GAMMA Insulator Company is the utility products manufacturing subsidiary of the Corona Group,
a multinational conglomerate with over 135 years manufacturing experience.

GAMMA's manufacturing facility is located in Colombia, South America, near the city of Medellín.

The Free Trade Agreement in force between Colombia and the United States provides
elimination of tariffs and removes barriers to the sale of our products in the US market.

GAMMA’s fully stocked North American warehouse, located in Houston, TX, provides a solution
for all immediate supply needs.

We hope this brochure will become a tool for decision-making processes and facilitate the
purchasing activity, making GAMMA your first choice for insulators.
Po
Polymer line post
Insulators for distribution
Ins

Ø2 3/8”
Ø2 4/5”

Hot dip /5
R3


R1
galvanized Steel Porcelain

11/10”
1 1/10” Ø1 7/10”

2 3/10”
Ø1 7/10” 10”
2 3/10” 11 3/10”

Ø3” Ø 3.0”
Ø4 2/5” Ø4 2/5”
Ø5 3/5” Ø5 3/5”

PL015 PL015H
STANDARD VERSION *HYBRID VERSION

CATALOG NUMBER PL015 PL015H


ANSI (C29.18)
Class 51-1F
Neck type F
CRITICAL DISTANCES, inches
Arcing distance 6 1/2 6 3/4
Leakage distance 13 7/10 14 7/10

MECHANICAL VALUES, Lb
SCL 5,000 3,000
Maximum density cantilever load 1,348 1,348
Tensile strength 5,000 3,000
ELECTRICAL VALUES,kV
Rated voltage 15 15
Low-frequency dry flashover 85 85
Low-frequency wet flashover 55 55
Critical impulse flashover, positive 150 150
Critical impulse flashover, negative 155 155

RADIO INFLUENCE VOLTAGE DATA


Low-frequency test voltage, RMS to ground, kV 10 10
Maximum RIV at 1,000 kHZ, μV 4 4
DIMENSIONS ACCORDING TO DRAWING
Center hole nominal thread size 3/4” 3/4”
Note1: Dimensions in inches.
* Combines a ceramic head and silicone elastomer housing properties superior leakage distance and reduced unit weight.
Housing: High voltage silicone - High temperature vulcanized (HTV).
Fittings: Hot dip galvanized steel.
Po
Polymer line post
Insulators for distribution
In

Ø 2 4/5”
Ø2 3/10”
Hot dip

R1
galvanized Steel Porcelain

R3

/5”
Ø1 4/5” Ø2 4/5”
Ø7/10”

Ø2 3/10”
Ø7/10”

Ø2 3/10”
13 7/10”
12 2/5”

Ø3”
Ø3”
Ø 4 2/5” Ø 4 2/5”
Ø5 1/5” Ø5 1/5”

PL028 PL028H
STANDARD VERSION *HYBRID VERSION

CATALOG NUMBER PL028 PL028H


ANSI (C29.18)
Class 51-2F
Neck type F
CRITICAL DISTANCES, inches
Arcing distance 8 4/5 9 7/32
Leakage distance 22 22 4/5

MECHANICAL VALUES, Lb
SCL 5,000 3,000
Maximum density cantilever load 1,348 1,348
Tensile strength 5,000 3,000
ELECTRICAL VALUES,kV
Rated voltage 29 29
Low-frequency dry flashover 100 100
Low-frequency wet flashover 75 75
Critical impulse flashover, positive 175 175
Critical impulse flashover, negative 190 190
RADIO INFLUENCE VOLTAGE DATA
Low-frequency test voltage, RMS to ground, kV 10 10
Maximum RIV at 1,000 kHZ, μV 4 4
DIMENSIONS ACCORDING TO DRAWING
Center hole nominal thread size 3/4” 3/4”
Note1: Dimensions in inches.
* Combines a ceramic head and silicone elastomer housing properties superior leakage distance and reduced unit weight.
Housing: High voltage silicone - High temperature vulcanized (HTV).
Fittings: Hot dip galvanized steel.
Po
Polymer line post
Ins
Insulators for distribution

Ø 2 4/5” Ø2 3/10
Hot dip
galvanized Steel

R3
R1

/5”
Porcelain


1 4/5”
1 4/5”
Ø 7/10”

2 3/10”
Ø7/10”

2 3/10”
14 4/5”
16 1/10”

Ø3” Ø3”
Ø4 2/5” Ø4 2/5”
Ø5 3/5” Ø5 3/5”

PL035 PL035H
STANDARD VERSION *HYBRID VERSION

CATALOG NUMBER PL035 PL035H


ANSI (C29.18)
Class 51-3F
Neck type F
CRITICAL DISTANCES, inches
Arcing distance 11 1/5 11 9/16
Leakage distance 30 1/4 30 3/4

MECHANICAL VALUES, Lb
SCL 5,000 3,000
Maximum density cantilever load 1,348 1,348
Tensile strength 5,000 3,000
ELECTRICAL VALUES,kV
Rated voltage 35 35
Low-frequency dry flashover 130 130
Low-frequency wet flashover 95 95
Critical impulse flashover, positive 210 210
Critical impulse flashover, negative 230 230
RADIO INFLUENCE VOLTAGE DATA
Low-frequency test voltage, RMS to ground, kV 10 10
Maximum RIV at 1,000 kHZ, μV 4 4

DIMENSIONS ACCORDING TO DRAWING


Center hole nominal thread size 3/4” 3/4”
Note1: Dimensions in inches.
* Combines a ceramic head and silicone elastomer housing properties superior leakage distance and reduced unit weight.
Housing: High voltage silicone - High temperature vulcanized (HTV).
Fittings: Hot dip galvanized steel.
Poly
Polymer line post
Insulators for distribution
Insu

Ø2 4/5”
Hot dip Ø2 4/5”

R1
galvanized Steel

R3

/5
Porcelain


Ø7/10”
Ø1 7/10”
1 1/10”
1 1/10”
18 2/5” 17 1/5”

2 3/10”
2 3/10”

Ø3” Ø3”
Ø 4 2/5” Ø 4 2/5”
Ø5 3/5” Ø5 3/5”

PL046 PL046H
STANDARD VERSION *HYBRID VERSION
CATALOG NUMBER PL046 PL046H
ANSI (C29.18)
Class 51-4F
Neck type F
CRITICAL DISTANCES, inches
Arcing distance 13 3/5 13 15/16
Leakage distance 38 1/2 38 13/16

MECHANICAL VALUES, Lb
SCL 5,000 3,000
Maximum density cantilever load 1,348 1,348
Tensile strength 5,000 3,000
ELECTRICAL VALUES,kV
Rated voltage 46 46
Low-frequency dry flashover 148 148
Low-frequency wet flashover 120 120
Critical impulse flashover, positive 250 250
Critical impulse flashover, negative 270 270

RADIO INFLUENCE VOLTAGE DATA


Low-frequency test voltage, RMS to ground, kV 10 10
Maximum RIV at 1,000 kHZ, μV 4 4

DIMENSIONS ACCORDING TO DRAWING


Center hole nominal thread size 3/4” 3/4”
Note1: Dimensions in inches.
* Combines a ceramic head and silicone elastomer housing properties superior leakage distance and reduced unit weight.
Housing: High voltage silicone - High temperature vulcanized (HTV).
Fittings: Hot dip galvanized steel.
WWW.GAMMAINSULATORS.COM
PHONE NUMBERS:
+1 (618) 649-4162
+1 (760) 742 9749

You might also like