You are on page 1of 1

TABLE OF CONTENTS

DRAWING SHEET
DESCRIPTION
NUMBER NUMBER
ARCHITECTURAL
PERPECTIVE 1-3 / 10
A-00-A-02 SITE DEVELOPMENT PLAN
VICINITY MAP
GROUND FLOOR PLAN
SECOND FLOOR PLAN
ROOF PLAN
GROUND FLOOR REFLECTED CEILING PLAN OFFICE OF THE BUILDING OFFICIALS
SECOND FLOOR REFLECTED CEILING PLAN GENERAL SANTOS CITY
DISTRICT/CITY/MUNICIPALITY
FRONT ELEVATION

RIGHT SIDE ELEVATION LAND USE & ZONING

LEFT SIDE ELEVATION


REAR ELEVATION
CROSS SECTION - 01
LONGITUDINAL SECTION - 01
WINDOW SCHEDULE
APPROVED BY DATE
DOOR SCHEDULE
STRUCTURAL LINE AND GRADE
FOUNDATION PLAN 4-6/ 10
SECOND FLOOR FRAMING PLAN
S-01-S-02 FOOTING DETAILS
FOOTING SCHEDULES
WALL FOOTING DETAILS
ROOF BEAM FRAMING PLAN
APPROVED BY DATE
COLUMN SCHEDULE & DETAIL
BEAM SCHEDULE & DETAIL ARCHITECTURAL
REINFORCE CONCRETE SLAB DETAIL TYPICAL
ROOF BEAM FRAMING PLAN
ROOF FRAMING PLAN
STAIR REINFORCEMENT DETAIL
SANITARY
WATER SERVICE PIPE LAYOUT GROUND FLOOR 9-10/ 10
3 PERSPECTIVES P-01- P-02
WATER SERVICE PIPE LAYOUT SECOND FLOOR
APPROVED BY DATE

A-000 SCALE NTS DRAINAGE PIPE LAYOUT GROUND FLOOR STRUCTURAL


DRAINAGE PIPE LAYOUT SECOND FLOOR
ISOMETRIC
15.00 m
SEPTIC TANK DETAIL
2.00 m 2.35 m 1.05 m
1.40 m 6.20 m 2.00 m SPECIFICATION
CATCH BASIN DETAIL
VICINITY MAP
APPROVED BY DATE
ELECTRICAL
LIGHTING LAYOUT GROUND FLOOR 7-8/ 10 SANITARY
E-01- E-02
LIGHTING LAYOUT SECOND FLOOR
7.00 m

7.00 m

POWER LAYOUT GROUND FLOOR

POWER LAYOUT SECOND FLOOR

POWER LAYOUT ROOF DECK FLOOR


APPROVED BY DATE
LOAD SCHEDULE
LOAD COMPUTATION ELECTRICAL
2.38 m

SINGLE LINE DIAGRAM


VICINITY MAP
4.01 m
25.00 m

25.00 m

APPROVED BY DATE
12.10 m

MECHANICAL

PROPOSED SINGLE
STOREY RESIDENTIAL
6.81 m

PROJECT SITE APPROVED BY DATE

GEODITIC ENGINEER
N
3.90 m
2.80 m
4.80 m

W E
2.00 m

2.00 m

APPROVED BY DATE

S FIRE PROTECTION

2.00 m 2.52 m 6.58 m 1.90 m 2.00 m

15.00 m
1 2 VICINITY MAP
SITE DEVELOPMENT PLAN
SCALE A-000
SCALE NTS
A-000 1 : 100M
APPROVED BY DATE

ARCHITECT: SECTION 25, REPUBLIC ACT 545 ENGINEER: PROJECT TITLE: APPROVED BY: SHEET CONTENTS: DRAWN BY: DRAWING NUMBER:
REF.NO. DATE:
Drawings and specifications duly signed, sealed or

A-000
CHECKED BY:
stamped, as instrument of service, are the property and
documents of the architect, whether the object for which - SINGLE STOREY RESIDENTIAL DATE:
they are made is executed or not. it shall be unlawful for
any person, without the written concent of the architect
REVISION NO.:DATE REVISED DRWG.NO.
or author of said document. to duplicate or to make
PRC.NO.: Date Issue: PRC.NO.: 0105636 Date Issue: LOCATION:
copies of said documents for use in repetition of and for
other projects or buildings, whether executed partly or
SHEET NUMBER
PTR.NO.: Place Issue: in whole. PTR.NO.: Place Issue: OWNER
T.I.N.NO.: T.I.N.NO.: ADDRESS: 1-7