Background:
It has been advised that the O-Rings utilized in the V8114AC container of the
CMZ500/Mod700 & CMZ700 Series Gyrocompass need to be replaced during the annual
overhaul. Furthermore, the addition of Supporting Liquid into the Air Chamber to ensure
proper operation of the Gyrocompass.
Objective:
This document will define to the Installing Engineer the proper procedure to accomplish
this task
Equipment Required:
#2 Phillips Screw Driver
Syringe, Large
Parts Used:
SK5700 – Seal Kit, CMZ500/MOD700 & CMZ700
SL5000 Or SL1000 – Supporting Liquid
Source:
AGMarine
CMZ500(mod700)/700 Maintenance Procedure Page 1 / 6
1-1. Service
Replace O-rings and Seal-Washer every assembling.
Also clean surface which O-rings and Seal-Washer will touch before fitting them.
Location of them is shown in Fig.-1 Container assy/
1-2.Background
O-ring or Seal-Washer which has been tightened will have invisible scratch or transform.
Re-using them may cause leakage.
2-1.Service
Remove Rubber Isolator and confirm form on overhauling. If the form has been changed as
below figure, Fig.-3 Change form of Rubber Isolator, replace it with new one(P/#. V8114FL).
*Confirmation must be done only while it is removed from Master compass, not confirm
while it is fitted in Master compass.
Universal Joint
Depth
Detail of A 2.0 mm
Fig.-2 Rubber Isolator
Depth
6.0 mm
New
Need to be replaced
2-2.Background
Form of Rubber Isolator will change due to long time use(2-3 years). Rubber isolator which
is like above figure, “Need to be replaced” does not have proper performance to absorb
vibration in ups and downs. This may cause unstable heading or damage on any parts such
as Centering pin.
3-1.Service
Upon disassembling, soak up Supporting liquid in Air-Chamber of Upper Container unit by Injector.
Before re-assembling Upper Container unit to Lower Container unit, insert 150cc of Supporting
liquid in Air-Chamber. Refer to Fig.-7 New.
3-2.Background
Air-Chamber has one hole(dia 3.0mm) to lead Gyrosphere compartment. There should be no
Supporting liquid in Air-Chamber upon assembling. Supporting liquid expanding for running
Gyrosphere, will ingress into Air-Chamber to avoid damage on Gyrosphere due to high pressure. .
Air-Chamber
Gyrosphere conpartment
Hole(dia 3.0mm)
However, too much Supporting liquid in Air-Chamber has been found on several systems. This
must be from Gyrosphere compartment and followings would be reason for the ingressing.
aa. Poor airtight of Air-Chamber (there is other hole). Then Supporting liquid can be ingressed
from Gyrosphere compartment without expanding.
bb. Gyrosphere compartment could not be filled up by Supporting liquid. In this case, Liquid
can be easily ingressed into Air-Chamber through hole(dia 3.0mm) when Container unit is
disturbing/vibrating although airtight of Air-Chamber was correct.
By adding Supporting liquid in Air-Chamber, Gyrosphere will work correctly because loss of liquid
in Gyropshere compartment will not be excessive.
AGMarine, Inc.
Attn: VSDepartment / Vessel Data File Archive
5711 34th Avenue NW, #201
Gig Harbor, WA 98335-8548
Info@agmarine.com
http://www.agmarine.com
2. Legal:
Gentle Reminder:
Travel costs other than auto mileage, tolls, and two (2) hours travel time, are
specifically excluded on all products. Travel costs, which are excluded from the
coverage of this Warranty, include, but are not limited to: taxi; launch fees,
aircraft rental, subsistence, customs, shipping, communication charges, etc.
Travel costs, mileage, and time; in excess to that allowed must have prior
approval from AGM in writing.
TM
5711 34th Avenue NW, #201
Gig Harbor, WA 98335-8548
§: 253.851.0862 ¨: 253.851.0865
Info@agmarine.com http://www.agmarine.com
{service@agmarine.com
Copyright Igcor, llc / Chat Lunatique / AGMarine, Inc 2000 ~ 2005™©
All rights reserved
-
Please Recycle