COLUMN DESIGN

COLUMN % of steel from


Floor Col. T ype GRID X GRID Y B D Area required Ast provided Pt provided Reinforcement Remarks
ID etabs
1 floor C 1 C7 0.4 0.4 0.93 1488 1608 1.01 8-F 16 OK
2 floor
C1 C 1 C7 0.4 0.4 0.8 1280 1608 1.01 8-F 16 OK
3 floor C 1 C7 0.35 0.35 0.98 1201 1257 1.03 4-F 16+4-F 12 OK

1 floor D 1 C10 0.4 0.4 1.15 1840 2061 1.29 8-F16 +4-F 12 OK
2 floor C1 D 1 C10 0.4 0.4 0.8 1280 1608 1.01 8-F16 +4-F 12 OK
3 floor D 1 C10 0.35 0.35 0.98 1201 1257 1.03 4-F 16+4-F 12 OK

1 floor C 1 C7 0.35 0.35 1.21 1482 1608 1.31 8-F 16 OK


2 floor C2 C 1 C7 0.35 0.35 1.01 1237 1257 1.03 4-F 16+4-F 13 OK
3 floor C 1 C7 0.35 0.35 0.98 1201 1257 1.03 4-F 16+4-F 14 OK

1 floor A 1 C1 0.35 0.35 0.85 1041 1257 1.03 4-F 16+4-F 12 OK


2 floor C2 A 1 C1 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK

1 floor A 2 C2 0.35 0.35 0.83 1017 1608 1.31 8-F 16 OK


2 floor C2 A 2 C2 0.35 0.35 1.17 1433 1608 1.31 8-F 16 OK

1 floor A 3 C3 0.35 0.35 0.9 1103 1257 1.03 4-F 16+4-F 12 OK


2 floor C2 A 3 C3 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK

1 floor B 1 C4 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK


2 floor C2 B 1 C4 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK
3 floor B 1 C4 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK

1 floor B 2 C5 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK


2 floor C2 B 2 C5 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK
3 floor B 2 C5 0.35 0.35 0.88 1078 1257 1.03 4-F 16+4-F 12 OK

1 floor B 2 C6 0.35 0.35 0.81 992 1257 1.03 4-F 16+4-F 12 OK


2 floor C2 B 2 C6 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK
3 floor B 2 C6 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK

1 floor C 2 C8 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK


2 floor C2 C 2 C8 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK
3 floor C 2 C8 0.35 0.35 0.88 1078 1257 1.03 4-F 16+4-F 12 OK

1 floor C 3 C9 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK


2 floor C2 C 3 C9 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK
3 floor C 3 C9 0.35 0.35 0.92 1127 1257 1.03 4-F 16+4-F 12 OK

1 floor D 2 C11 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK
2 floor C2 D 2 C11 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK
3 floor D 2 C11 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK

1 floor D 3 C12 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK
2 floor C2 D 3 C12 0.35 0.35 0.8 980 1257 1.03 4-F 16+4-F 12 OK
3 floor D 3 C12 0.35 0.35 0.96 1176 1257 1.03 4-F 16+4-F 12 OK

1 floor D 3 C12 1.13 1070 1206 1.71 6-F 16 OK


2 floor C3 D 3 C12 Dia of column = 0.3 1.51 799 1206 1.71 6-F 16 OK
3 floor D 3 C12 1.41 994 1206 1.71 6-F 16 OK
Beam Design
Grid ID position b D d Pt required Ast req. Ast provided Pt provided Reinforcement Remarks

left 0.23 0.355 0.315 0.64 522.56 628.3185307 0.77 3-F20+2-F16 OK


mid 0.23 0.355 0.315 0.4 326.6 628.3185307 0.77 3-F20+2-F16 OK
Top right 0.23 0.355 0.315 0.3 244.95 628.3185307 0.77 3-F20+2-F16 OK
1--1'
left 0.23 0.355 0.315 0.22 179.63 402.1238597 0.49 2-F16 OK
mid 0.23 0.355 0.315 0.22 179.63 402.1238597 0.49 2-F16 OK
Bottom right 0.23 0.355 0.315 0.22 179.63 402.1238597 0.49 2-F16 OK
left 0.23 0.355 0.315 0.27 220.455 402.124 0.49 2-F16 OK
mid 0.23 0.355 0.315 0.37 302.105 402.124 0.49 2-F16 OK
2--2 Top right 0.23 0.355 0.315 0.35 285.775 402.124 0.49 2-F16 OK
left 0.23 0.355 0.315 0.22 179.63 402.124 0.49 2-F16 OK
mid 0.23 0.355 0.315 0.37 302.105 402.124 0.49 2-F16 OK
Bottom right 0.23 0.355 0.315 0.24 195.96 402.124 0.49 2-F16 OK
left 0.23 0.355 0.41 0.37 302.105 402.124 0.49 2-F16 OK
mid 0.23 0.355 0.41 0.22 179.63 402.124 0.49 2-F16 OK
3--3 Top right 0.23 0.355 0.41 0.36 293.94 402.124 0.49 2-F16 OK
left 0.23 0.355 0.41 0.22 179.63 402.124 0.49 2-F16 OK
mid 0.23 0.355 0.41 0.22 179.63 402.124 0.49 2-F16 OK
Bottom right 0.23 0.355 0.41 0.22 179.63 402.124 0.49 2-F16 OK
left 0.23 0.355 0.315 0.36 293.94 515.221 0.63 12-F12+2-F16 OK
mid 0.23 0.355 0.315 0.22 179.63 515.221 0.63 12-F12+2-F16 OK
A--A Top right 0.23 0.355 0.315 0.4 326.6 515.221 0.63 12-F12+2-F16 OK
left 0.23 0.355 0.315 0.22 179.63 402.124 0.49 2-F16 OK
mid 0.23 0.355 0.315 0.22 179.63 402.124 0.49 2-F16 OK
Bottom right 0.23 0.355 0.315 0.22 179.63 402.124 0.49 2-F16 OK
left 0.23 0.355 0.315 0.31 253.115 402.124 0.49 2-F16 OK
mid 0.23 0.355 0.315 0.22 179.63 402.124 0.49 2-F16 OK
B--B Top right 0.23 0.355 0.315 0.31 253.115 402.124 0.49 2-F16 OK
left 0.23 0.355 0.315 0.22 179.63 402.124 0.49 2-F16 OK
mid 0.23 0.355 0.315 0.22 179.63 402.124 0.49 2-F16 OK
Bottom right 0.23 0.355 0.315 0.22 179.63 402.124 0.49 2-F16 OK
left 0.23 0.355 0.315 0.29 236.785 402.12 0.49 2-F16 OK
mid 0.23 0.355 0.315 0.22 179.63 402.12 0.49 2-F16 OK
C--C Top right 0.23 0.355 0.315 0.28 228.62 402.12 0.49 2-F16 OK
left 0.23 0.355 0.315 0.22 179.63 402.12 0.49 2-F16 OK
mid 0.23 0.355 0.315 0.22 179.63 402.12 0.49 2-F16 OK
Bottom right 0.23 0.355 0.315 0.22 179.63 402.12 0.49 2-F16 OK
left 0.23 0.355 0.315 0.41 334.765 515.22 0.63 12-F12+2-F16 OK
mid 0.23 0.355 0.315 0.22 179.63 515.22 0.63 12-F12+2-F16 OK
D--D Top right 0.23 0.355 0.315 0.37 302.105 515.22 0.63 12-F12+2-F16 OK
left 0.23 0.355 0.315 0.24 195.96 402.12 0.49 2-F16 OK
mid 0.23 0.355 0.315 0.22 179.63 402.12 0.49 2-F16 OK
Bottom right 0.23 0.355 0.315 0.22 179.63 402.12 0.49 2-F16 OK
left 0.23 0.23 0.19 0.2 105.8 226.194 0.43 2-F12 OK
mid 0.23 0.23 0.19 0.2 105.8 226.194 0.43 2-F12 OK
Plinth Beam Top right 0.23 0.23 0.19 0.2 105.8 226.194 0.43 2-F12 OK
left 0.23 0.23 0.19 0.2 105.8 226.194 0.43 2-F12 OK
mid 0.23 0.23 0.19 0.2 105.8 226.194 0.43 2-F12 OK
Bottom right 0.23 0.23 0.19 0.2 105.8 226.194 0.43 2-F12 OK
left 0.23 0.355 0.315 0.91 743.015 829.38 1.02 3-F16+2-F12 OK
mid 0.23 0.355 0.315 0.63 514.395 829.38 1.02 3-F16+2-F12 OK
Top right 0.23 0.355 0.315 0.91 743.015 829.38 1.02 3-F16+2-F12 OK
Stair Beam
left 0.23 0.355 0.315 0.74 604.21 628.318 0.77 2-F16+2-F12 OK
mid 0.23 0.355 0.315 0.69 563.385 628.318 0.77 2-F16+2-F12 OK
Bottom right 0.23 0.355 0.315 0.77 625.439 628.318 0.77 2-F16+2-F12 OK