DESIGN OF A SQUARE/RECTANGULAR FOOTING
REFERENCE:
FOOTING No: GRID Ref: 8 - KL
Fc= 40 N/MM² COLUMN DIMENSIONS
Fy= 460 N/MM² a= 200 MM
SBC OF SOIL = 150 N/MM² b= 600 MM
LOAD FROM COLUMN= 1200 kN
(UNFACTORED LOAD)
MOMENT Mxx= 0 KN-m L= 3200 MM
MOMENT Myy= 0 KN-m B= 3000 MM
SOIL ABOVE FOOTING (Hs)= 0.7 m D= 500 MM
DENSITY OF CONCRETE = 25 kN/m³ COVER= 50 MM
DENSITY OF SOIL ABOVE = 16 kN/m³
SELF WEIGHT OF SOIL ABOVE = 106.176 Kn Eff Depth (d)= 442 MM
SELFWEIGHT OF FOOTING= 120.00 Kn 8 (Y)
AREA OF FOOTING REQUIRED= 9.51 m²
Mxx
B =3 m
AREA OF FOOTING PROVIDED= 9.6 m²
AREA RECOMMENDED= (3.09 X 3.09)m b (X)
AREA PROVIDED IS SAFE KL Myy a KL
5.12 m⁴
Zxx=
4.80 m⁴
Zyy= L=3.2 m
Net PRESSURE(Ver LOAD ONLY)= 125.00 kN/MM²
PRESSURE MAX (MOMENT)= 125.00 kN/MM² 8
PRESSURE MIN (MOMENT)= 125.00 kN/MM²
SOIL PRESSURES WITHIN LIMITS
X-X DIRECTION Y-Y DIRECTION
D= 0.5 Hs =0.7 m
MAX BM= 140.63 KN-m MAX BM= 90.00 KN-m SOIL b =0.6
ULT BM= 210.94 KN-m ULT BM= 135.00 KN-m
Ast Reqd= 1232.62 MM² Ast Reqd= 779.38 MM²
% St Reqd= 0.28 % % St Reqd= 0.18 %
16 MM Ø 150 MM C/C 1340.41 X-Direction L=3.2 m
16 MM Ø 150 MM C/C 1340.41 Y-Direction
% OF STEEL PROVIDED IN X- DIRECTION = 0.30 OK
% OF STEEL PROVIDED IN Y- DIRECTION = 0.30 OK
CHECK FOR SHEAR
1.5d 1.0d 0.5d d
PERIMETER 6904 5136 3368 1600
SHEAR FORCE 1248.92 1498.38 1674.57 1800.00
Vu 0.409 0.660 1.125 1.697
Vc 0.497 0.745 1.490 5.000
SHEAR CHECK ÖK ÖK ÖK ÖK