Professional Documents
Culture Documents
01 2022
Product Catalog
Index
General Information - Features A2
Fluids and filtering A6
Service life of bearings for axial piston units A11
General installation guidelines A16
Nominal values calculation A23
Conversion Factor A24
Product Identification A25
SH11C Fixed displacement motors B1
SH11CR Plug-in fixed displacement motors for gearbox C1
SH11C Fixed displacement pumps D1
H1C Fixed displacement pumps/motors E1
H1CR Plug-in fixed displacement motors for gearbox F1
H1V Variable displacement axial piston pumps for open circuit G1
S5AV Variable displacement axial piston pumps for open circuit H1
HD1 Variable displacement axial piston pumps for closed circuit I1
S6CV Variable displacement axial piston pumps for closed circuit L1
SH7V Variable displacement axial piston motor for open and closed circuit M1
SH7VR Plug-in variable displacement motor for gearbox N1
SH9V Variable displacement axial piston motor for open and closed circuit O1
MAV4211SH Electronic control card P1
VALVES Valves Q1
Dana has introduced the interactive index and bookmarks, which allow you to arrive and print the relevant section faster
DC5A1G1_0000000 - 01/22
i/01
A2 General information - Features
SH11C Sez. D
• Fixed displacement
• For open circuit
• ISO and SAE version
• Displacements 10-16-20-30-45-55-63-
75-90-108-125 160-180 cm³/rev
• Nominal pressure 430 bar [6240 psi]
• Peak pressure 480 bar [6960 psi]
H1C Sez. E
• Fixed displacement
• For open and closed circuit
• Displacements 20-30-45-55-63-75-90
108-125-160-180 cm³/rev
• Nominal pressure 430 bar [6240 psi]
• Peak pressure 480 bar [6960 psi]
H1V Sez. G
• Variable displacement
• For open circuit
• ISO and SAE version
• Displacements 55-75-108-160-226 cm³/rev
• Nominal pressure 350 bar [5080 psi]
• Peak pressure 450 bar [6530 psi]
DC5A1G1_0000000 - 01/22
i/01
General information - Features A3
S5AV Sez. H
• Variable displacement
• For open circuit
• Displacements 32-45-50-63-75-93 cm³/rev
• Nominal pressure 280÷350 bar [4060÷5080 psi]
• Peak pressure 350÷420 bar [5080÷6090 psi]
HD1 Sez. I
• Variable displacement
• For closed circuit
• ISO and SAE version
• Displacement 55 cm³/rev
• Nominal pressure 420 bar [6090 psi]
• Peak pressure 450 bar [6530 psi]
S6CV Sez. L
• Variable displacement
• For closed circuit
• ISO and SAE version
• Displacements 75-128 cm³/rev
• Nominal pressure 400 bar [5800 psi]
• Peak pressure 450 bar [6530 psi]
DC5A1G1_0000000 - 01/22
i/01
A4 General information - Features
SH11C Sez. B
• Fixed displacement
• For open circuit
• ISO and SAE version
• Displacements 10-16-20-30-45-55-63-
75-90-108-125 160-180 cm³/rev
• Nominal pressure 430 bar [6240 psi]
• Peak pressure 480 bar [6960 psi]
SH11CR Sez. C
• Fixed displacement
• For open and closed circuit
• Displacements 20-30-45-55-63-75-90
108-125-160-180 cm³/rev
• Nominal pressure 430 bar [6240 psi]
• Peak pressure 480 bar [6960 psi]
H1C Sez. E
• Fixed displacement
• For open and closed circuit
• Displacements 20-30-45-55-63-75-90
108-125-160-180 cm³/rev
• Nominal pressure 430 bar [6240 psi]
• Peak pressure 480 bar [6960 psi]
H1CR Sez. F
• Fixed displacement
• For open and closed circuit
• Displacements 45 cm³/rev
• Nominal pressure 350 bar [5080 psi]
• Peak pressure 450 bar [6530 psi]
DC5A1G1_0000000 - 01/22
i/01
General information - Features A5
SH7V Sez. M
• Variable displacement
• For open and closed circuit
• ISO and SAE version
• Displacements 55-75-108-160-200 cm³/rev
• Nominal pressure 430 bar [6240 psi]
• Peak pressure 480 bar [6960 psi]
SH7VR Sez. N
• Variable displacement
• For open and closed circuit
• ISO and SAE version
• Displacement 55-75-108-160 cm³/rev
• Nominal pressure 430 bar [6240 psi]
• Peak pressure 480 bar [6960 psi]
SH9V Sez. O
• Variable displacement
• For open and closed circuit
• ISO and SAE version
• Execution with 9 pistons for greater torque and
smoothness rotation
• Displacements 61-85-115-165-215 cm³/rev
• Nominal pressure 430 bar [6240 psi]
• Peak pressure 480 bar [6960 psi]
DC5A1G1_0000000 - 01/22
i/01
A6 Fluids and filtering
HL Anticorrosive, antioxidant
Flame-resitant fluids
HFA Oil-based emulsion in water (water > 90%)
Organic fluids
HETG Vegetable-based fluids
2. Viscosity index
The optimum viscosity of the fluid νopt at the operating temperature (temperature of the tank for open circuits or temperature of the
circuit for closed circuits) must fall between the minimum and maximum values shown in the table below. The minimum viscosity
νmin shown in the table is permitted in extreme conditions and for short periods. This value refers to a maximum fluid temperature
of 90°C (temperature of drainage fluid). The maximum viscosity νmax for short intervals and during cold starts is shown in the table
below. The temperature of the fluid must never exceed a maximum of +90°C and a minimum of -25°C.
DC5A1G1_0000000 - 01/22
i/01
Fluids and filtering A7
3. Viscosity grades
Under the ISO standard, hydraulic fluids are divided into 6 grades of viscosity (see table below). Viscosity grades are shown by
the letters VG followed by the viscosity of the fluid in cSt at a temperature of 40 °C.
ν 40°
ISO viscosity grades
(cSt)
VG 10 9 ÷ 11
VG 22 19.8 ÷ 24.2
VG 32 28.8 ÷ 35.2
VG 46 41.4 ÷ 50.6
VG 68 61.2 ÷ 71.5
VG 188 90 ÷ 110
In order to choose the correct type of fluid, it is essential to know the operating temperature of the fluid (temperature of the tank
for open circuits or temperature of the circuit for closed circuits) and its viscosity index. At the operating temperature, the viscosity
of the fluid must fall within the optimum viscosity values (νopt). The diagram below shows the variations of viscosity at various
temperatures of a class of fluids sharing the same viscosity index.
5000 VG100
3000
VG68
1500
1000 VG46
600 VG32
400
300 VG22
200 VG10
150
100
80
60
50
Viscosity
40 40
ν (cSt)
30
25
ν0pt
20
16
14 15
11
9
8
7
6
5
4.5
4.0
3.5
3.0
2.6
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 °C
T (°C)
Temperature
* The diagram is only an example. It shows the viscosity–temperature characteristics of typical fluids with different viscosities but
sharing the same viscosity index. Ask to your hydraulic fluid supplier for the real viscosity-temperature diagram of the fluid used in
your system.
DC5A1G1_0000000 - 01/22
i/01
A8 Fluids and filtering
Example: in a fully operational system, the operating temperature of the fluid is 50°. Suitable fluids for this type of system are those
with viscosity which falls within the range νopt at a temperature of 50° (VG32 and VG46 in this case). The operating temperature of
a fluid in a system depends on a large number of factors. The temperature stabilises when the heat produced by the system (due
to mechanical friction and rolling of the fluid) is equal to the heat released outside (heat exchangers and tank). Since the heat
produced increases at the same rate as the difference between the ambient temperature and that of the system, the system has a
specific thermal equilibrium temperature for every ambient temperature. As a result, the working environment must be taken into
consideration when choosing a fluid. A machine located in North Africa, for example, should be operated with a different type of
fluid to a machine in northern Europe.
4. Contamination levels
Efficient filtering is essential if an hydraulic system is to work correctly. A good quality fluid extends the working life of hydraulic
parts and makes the system more reliable. Bent axis units usually have a higher tolerance of pollutants than swash plate ones.
Dana allows the following maximum permissible contamination grades for its axial piston units:
S6CV 20/18/15
S5AV 20/18/15
Axial piston pumps usually work satisfactorily even if the fluid does not meet the maximum contamination standard mentioned
above. However, experience has shown that keeping the contamination grade below certain limits and a good quality of the
hydraulic fluid (antifoaming capacity, anti-wear additives, etc.) is essential for the durability and efficient operation of hydraulic
systems.
5. Filtering grade
ISO 16889 standard states that the filtering grade βx(c) is the ratio between the number of particles of pollutant (per unit of volume)
of a size greater than or equal to “x”μm(c) entering the filter and the number of particles of the same size leaving the filter. The
grade βx(c) therefore gives an indication of the efficiency of the filter.
Radio
Filtering capacity Notes
βx(c)
≥2 50% Average size of filter pores equal to smallest particles retained
≥ 20 95% Normal retention
≥ 100 99% Absolute retention
Example: A filter with a filtering ratio of β10(c) ≥ 100 is able to capture almost all particles greater than or equal to 10 μm(c). To
achieve the correct contamination level, Dana recommends filters with the following βx(c) ratios for its axial pis-ton pumps):
DC5A1G1_0000000 - 01/22
i/01
Fluids and filtering A9
130.000.000 250.000.000 28
64.000.000 130.000.000 27
32.000.000 64.000.000 26
16.000.000 32.000.000 25
8.000.000 16.000.000 24
4.000.000 8.000.000 23
2.000.000 4.000.000 22
1.000.000 2.000.000 21
500.000 1.000.000 20
250.000 500.000 19
130.000 250.000 18
64.000 130.000 17
32.000 64.000 16
16.000 32.000 15
8.000 16.000 14
4.000 8.000 13
2.000 4.000 12
1.000 2.000 11
500 1.000 10
250 500 9
130 250 8
64 130 7
32 64 6
16 32 5
8 16 4
4 8 3
2 4 2
1 2 1
0 0 0
DC5A1G1_0000000 - 01/22
i/01
A10 Fluids and filtering
Looking at the table in page 8, the code 21/15/11 of ISO 4406:1999 standard states that in a volume unit of 1 ml are present:
Between 10000 and 20000 particles of dimension ≥ 4 µm (c);
Between 160 and 320 particles of dimension ≥ 6 µm (c);
Between 10 and 20 particles of dimension ≥ 14 µm (c).
The recommended levels above are referred to normal operating conditions and a normal environment. Should the unit be used
with particular kind of fluids or in corrosive environments please contact us.
DC5A1G1_0000000 - 01/22
i/01
Service life of bearings for axial piston units A11
1. Introduction
The sliding surfaces of the moving parts in the pumps/motors are protected by a film of oil which provides lubrication and hydrostatic
balancing and the related wear is negligible when optimum filtration and recommended operating conditions are achieved. Therefore
the operating life of the pumps/motors can be defined by bearing life. L10h factor of bearing life means that 90% of the bearings will last
longer than the number of hours calculated. In practice 50% of the bearings will last more than five times the L10h life. L10h bearing life is
dependent on operating pressure and speed and also on external shaft loads and fluid viscosity. L10h bearing life at given pressure and
speed can be estimated by the formula:
Where L0 is the L10h life (in hours) of the bearings at n0 rpm and p0 bar (the operating pressure is the sum of pressures on the motor
inlet and outlet ports or pump delivery and suction ports), n1 is the speed of the shaft in rpm, p1 is the operating pressure in bar
and L1 is the estimated service life (in hours) at a pressure of p1 and a speed of n1.
Note: Dana has a computer program for determining the estimated operating bearing life. It is our commitment to help and assist you in
determining life at specific operating conditions and cycle. Please contact us should you require it.
2. Operating cycle
When the operating cycle of the pumps/motors shows time variant (alone or in combinations) of speed and pressure, the bearing life
formula comes to:
service life of the bearings at a pressure of pi and a speed of ni, Ti is the length of the cycle during which the unit operates at a
speed of ni and a pressure of pi and Tt is the total length of the cycle.
DC5A1G1_0000000 - 01/22
i/01
A12 Service life of bearings for axial piston units
2.4
2.2
2.0
40
Viscosity
1.8
ν (cSt)
a23
23
35
a
30 1.6
25
1.4
20
1.2
15
1
1200 1800 2400 3000 3600 4200 4800 5400 rpm
nSpeed
(rpm)
5. S6CV pump
The drive shaft can stand both radial and axial loads. The maximum permissible loads in the following table are calculated in such
a way as to guarantee a service life of at least 80% of the service life of bearings to which no load is applied.
Fq Displacement
+ Fax 75 128
- Fax N 2400 4600
Radial load Fq max [lbf] [540] [1035]
N 1900 4300
Axial load Fax max [lbf] [428] [967]
X/2 X/2
6. S5AV pump
The drive shaft can stand both radial and axial loads. The maximum permissible loads in the following table are calculated in such
a way as to guarantee a service life of at least 80% of the service life of bearings to which no load is applied.
Fq Displacement
+ Fax
32/45 50/63 75/90
- Fax N 1000 1500 2400
Radial load Fq max [lbf] [225] [338] [540]
N 1200 1500 1900
Axial load Fax max [lbf] [270] [338] [428]
X/2 X/2
DC5A1G1_0000000 - 01/22
i/01
Service life of bearings for axial piston units A13
120%
Alternating rotation
CW motor
φ φ CCW motor
100%
90% B A
80%
70%
-180 -135 -90 -45 0 45 90 135 180
φ (°)
The bearing operating life increases up to 30% when the load is applied with some peculiar directions and the maximum
increase is dependent on the operating pressure and the nominal size of the unit. The following table is a guide to determine
max. permissible radial loads. Values are calculated in such a way to assure at least 80% of the bearing operating life where no
radial load is applied. The published values are related to loads applied midshaft and in the least favourable direction. The max
permissible load is dependent on the operating pressure and the values are in N/bar.
DC5A1G1_0000000 - 01/22
i/01
A14 Service life of bearings for axial piston units
Pushing loads
Within certain limits and at low operating pressure, pushing loads do not affect the bearing operating life. The following table
shows maximum pushing axial loads at pressures less than 100 bar [1450 psi]. At pressures above 100 bar [1450 psi], higher
pushing loads may be applied in proportion to the pressure increase. Pushing loads tend to extend the bearing operating life.
Pulling loads
Pulling loads always reduce the bearing operating life. The following table shows maximum pulling axial loads which, at pressures
of 250 bar [3625 psi] and 350 bar [5075 psi], assure an operating life more than 80% of the service life under no axial loads.
Where possible pulling loads should be avoided.
< 100 bar [<1450 psi] > 100 bar [>1450 psi] 250 bar [3625 psi] 350 bar [5075 psi]
H1C H1V - H2V
N [lbf] N [lbf] N [lbf] N [lbf]
< 100 bar [<1450 psi] > 100 bar [>1450 psi] 250 bar [3625 psi] 350 bar [5075 psi]
SH11C
N [lbf] N [lbf] N [lbf] N [lbf]
Pushing < 100 bar [<1450 psi] > 100 bar [>1450 psi] 250 bar [3625 psi] 350 bar [5075 psi]
SH7V
loads N [lbf] N [lbf] N [lbf] N [lbf]
DC5A1G1_0000000 - 01/22
i/01
Service life of bearings for axial piston units A15
6 6 [1.585] 55 10 [2.642]
12 6 [1.585] 75 10 [2.642]
226 20 [5.283]
075 5 [1.32]
090 5 [1.32]
108 10 [2.642]
125 10 [2.642]
160 15 [3.963]
180 15 [3.963]
DC5A1G1_0000000 - 01/22
i/01
A16 General installation guidelines
These general installation and commissioning specifications are intended for Dana axial piston units. Adherence to these
recommendations has a decisive effect on the service life of the units. The following specifications refer to standard units with
standard internal elements, used with common hydraulic fluids. Carefully read these notes before installing and commissioning
the application. For every unit type, a specific installation and commissioning manual is available: please ask for a copy. In case
of doubt, please contact us.
OIL OIL
2. Connections
To reduce noise levels, rigid pipes with short flexible hoses sections are recommended (suction and return hoses, delivery and
drain hoses respectively for pumps and motors plus a bleed hose). Suction and drainage hoses should be as short and straight
as possible. Ensure that pressure drops in lines are not caused by couplings, elbows and differences in diameter, particularly in
suction hoses.
Where rigid pipes are used, ensure that the pipes do not put stresses on the piston unit ports. All lines connected to the tank
(suction, return and drainage lines) should be immersed at least 200 mm [7.80 in] below the minimum oil level and at least 150
mm [5.85] in from the bottom of the tank.
DC5A1G1_0000000 - 01/22
i/01
General installation guidelines A17
Fluid velocity
Service
m/s
Suction / intake 0.6 ÷ 1.2
Drain line 1.5 ÷ 4
Pressure lines 2 ÷ 5.5
The lower the fluid velocity is kept, the more efficient and safe the operation of the pump will be. Practical and cost limitations will
tell how far to go in this direction. To Calculate fluid velocity (see also Flow - Velocity Nomogram in the following page):
v = Q × 21.22 / D2
Where:
v = velocity in metres per second (m/sec)
Q = flow rate in litres per minute (l/min)
D = inside diameter of pipe or hose in millimetres (mm)
Example:
if boost pump of an S6CV 75 is (18 cm3/giro [1.09 in3/rev]) and maximum engine speed is 2200 rpm the boost pump output flow
will be about 40 l/min [10.56 U.S. gpm].
To avoid cavitation conditions or not fall below 0.8 bar [11.6 psi] absolute pressure in the suction line a 1 m/s fluid velocity is to be
considered as acceptable. At 40 l/min [10.56 U.S. gpm] this require a line of 29 mm [1.13 in] minimum inside diameter (1 1/4 G
BSPP). An effective solution is to use both FA1 and FA2 ports connected to the selected 1 1/4 G (BSPP) suction line via a T fitting,
splitting the line in two (as short as possible) 1 G (BSPP) sections. Always avoid elbows and sharp bends.
When the pump is in neutral the flow above is the amount of flow that will pass through the case drain ports and drain lines. If the
pump is working under load the case drain flow can be increased due to external leakage flow peaks. Considering a 8% reduction
of pump efficiency under peak loading conditions, the case drain lines can be dimensioned for
This, considering a flow velocity of 3.0 m/s requires a 3/4 G (BSPP) drain line.
As for the pressure lines, the maximum output flow of the S6CV 75 @ 2200 rpm is 165 l/min [43.56 U.S. gpm]. Using an optimum
3.5 m/sec flow velocity the required line diameter should be 30 mm [1.17 in], close to a 1 1/4 G (BSPP) line.
WARNING:
whatever is the theoretical calculation, NEVER use fittings or line diameters lower than the port dimension on the pump. Larger
lines are viceversa welcome.
DC5A1G1_0000000 - 01/22
i/01
A18 General installation guidelines
} Recommended
Recommended
velocityrange
velocity
for
forintake
range
intakelines
lines
v (m/sec)
q (l/min)
Ø (mm)
} Recommended
Recommended
velocity range
Flow
Bore diameter
Flow velocity
velocity range
forpressure
for pressurelines
lines
5. Drive shaft
Take special care to ensure that the units are correctly flanged and coupled. Ensure that the shaft and flange are lined up ac-
curately to prevent additional loads on the shaft bearings. Flexi-ble couplings should be used for pumps. Caution: incorrectly
aligned parts significantly reduce the service life of the bear-ings.
6. Installation position
Pumps and motors may be installed both above and below the level of the fluid in the tank, that is, the lowest level of the oil when
the system is in use (see note 6 and 7). When the circuits are open, the oil level is influenced by the number and size of any
hydraulic cylinders used on the system. In case of mobile installations it is important to take into account the slope of the ground
and the effect of centrifugal forces on the oil level.
DC5A1G1_0000000 - 01/22
i/01
General installation guidelines A19
Special requirement for H1V units when mounted above the tank:
H1V series variable piston pumps must always be installed horizontally with the intake turned upwards. The suc-tion hose should
be curved upwards and positioned higher than the pump to prevent fluid from draining from the casing when the machine is out
of service (Figure 3) and should have a check valve. Observe the maximum levels shown in Figure 3. Caution: above the reservoir
the pump must never be operated with zero displacement; a minimum displacement of 5% of the maximum value is essential.
Warning:
it is a general recommendation to mount all pumps below the tank where possible.
50mm [1.97 in]
DC5A1G1_0000000 - 01/22
i/01
A20 General installation guidelines
9. First starting
Before starting fill the system components with new and filtered oil. In addition fill the pre-cleaned reservoir with the same type of
oil. We recommend to flush the circuit. Verify that charge pressure is correct (closed circuits). Restore oil level inside reservoir.
10. Flushing
In case bent axis design axial piston motors and bent axis design axial piston pumps for open circuit are installed with shaft
turned upwards, and/or in case of high oil temperature inside the tank (>50°), and/or in case units are used for a long operation
time at high pressures (>250 bar [>3625 psi]), it is recommended to flush motor/pump bearings, by using oil at equal or lower
temperature than the tank one. Flush the bearing through the port R (Figure 4).
Warning:
H1V pumps with constant pressure control (PC, CR, PI+PC etc.) must be always flushed in case of zero stroke operation for more
than 5 min. and a working pressure higher than 250 bar [3626 psi]. In this case it is recommended the use of both the R and S1 or
S2 ports (Figure 4).
Flushing fluid
The flushing can be stopped as the oil contamination level in the closed loop according to ISO 4406:1999 is at least conformal to
the values shown in ”Recommended contamination levels” of page A/9 or lower. The same maximum acceptable oil contamination
level applies to the whole circuit. When the flushing is completed, the in line filter and the eventual auxiliary hoses must be
removed to configure the circuit to the design layout. After the circuit has been restored to the design layout, the machine can be
tested under load, and the eventual pressure adjustments and final tests can be done.
DC5A1G1_0000000 - 01/22
i/01
General installation guidelines A21
Circuit example
PS GS GA
S1
V1 A
V4
V2
R1 R2
T
V3
B
S2
X2 X1 P L1L2 L3 GT FA FA1 GB
PS GS GA
S1
V1 A
A V4
V2
4 μm absolute
R1 R2
V3
B
S2
X2 X1 P L1L2 L3 GT FA FA1 GB
B V4
V2
R1 R2 4 μm absolute
T
V3
S2
X2 X1 P L1L2 L3 GT FA FA1 GB
DC5A1G1_0000000 - 01/22
i/01
A22 General installation guidelines
12. Maintenance
First oil change to be made after approximately 500 hours of operation. Filter cartridge must be replaced first time after 50 hours
for preliminary circuit cleaning and then every 500 hours. Subsequent oil change every 2000 hours.
Such intervals should be reduced when the filter clogging indicator shows that the cartridge is clogged or when the system works
in a heavily polluted environment and/or at high temperatures and/or high pressure.
DC5A1G1_0000000 - 01/22
i/01
Nominal values calculation A23
Output flow
Vg × n × v
Q=
1000
Drive torque
p × Vg 1
M= ×
62.8 hm
Driver power
M × n Q × ∆p 1
W= = ×
9550 600 ɻt
Input flow
Vg × n 1
Q= ×
1000 v
Output torque
p × Vg × hm
M=
62.8
Output power
M × n Q × ∆p t
W= =
9550 600
Output speed
Q × 1000 v
n=
DC5A1G1_0000000 - 01/22
i/01
A24 Conversion factors
The following table shows the conversion factor from the Metric system to English (or American) system for the main units used in
hydraulics.
to convert to convert
multiply by multiply by
from to from to
length mm in 0.039 in mm 25.4
capacity I gal 0.219 gal I 4.546
mass kg Ib 2.204 Ib kg 0.4536
force N Ibf 0.225 Ibf N 4.45
torque N·m Ibf·ft 0.737 Ibf·ft N·m 1.357
pressure bar psi 14.5 psi bar 0.06895
flow l/min U.S. gpm 0.264 U.S. gpm l/min 3.79
power kW hp 1.34 hp kW 0.746
rotation speed giri/min r.p.m. 1 r.p.m. giri/min 1
displacement cm3/giro in3/rev 0.061 in3/rev cm3/giro 16.387
temperature °C °F 1.8x°C+32 °F °C (°F-32)/1.8
DC5A1G1_0000000 - 01/22
i/01
Product identification A25
Data plate
Each Dana AXIAL products are supplied with an identification data plate. The full identification of the product is made only through
the serial number. Every request of information must quote this number.
OLD SOLUTION
Product Product
description description
XXXXXXXXX XXXXXXXXX
YYMM-SSSSSS YYMM-SSSSSSBB
Serial Serial
number number
YY = Year of production YY = Year of production
MM = Month of production MM = Month of production
SSSSSS = Batch number SSSSSS = Batch number
BB = Batch progressive number
OLD SOLUTION
Product Product
description description
XXXXXXXXX XXXXXXXXX
Serial Serial
number number
YY = Year and month of production YY = Year and month of production
(see the perpetual calendar) (see the perpetual calendar)
SSSSSS = Batch number SSSSSS = Batch number
/BB = Batch progressive number (where required) /BB = Batch progressive number (where required)
DC5A1G1_0000000 - 01/22
i/01
DC5A1G1_0000000 - 01/22
SH11C - Fixed displacement motors B1
Index
SH11C 020 19.9 [1.213] 125 [33.00] 430 [6235] 480 [6960]
SH11C 030 31.9 [1.945] 201 [53.06] 430 [6235] 480 [6960]
SH11C 055 56.35 [3.437] 282 [74.45] 430 [6235] 480 [6960]
SH11C 063 63.26 [3.859] 316 [83.42] 430 [6235] 480 [6960]
SH11C 075 77.82 [4.747] 350 [92.4] 430 [6235] 480 [6960]
SH11C 090 86.23 [5.26] 388 [102.5] 430 [6235] 480 [6960]
SH11C 108 108.4 [6.612] 433 [114.31] 430 [6235] 480 [6960]
SH11C 125 124.8 [7.613] 500 [132.00] 430 [6235] 480 [6960]
SH11C 160 163.9 [9.998] 590 [155.76] 430 [6235] 480 [6960]
SH11C 180 178.1 [10.864] 641 [169.22] 430 [6235] 480 [6960]
SH11C motors are a family of fixed displacement, bent axis piston motors for operation in both open and closed circuit.
The proven design incorporating the lens shape valve plate, the high quality components and manufacturing techniques make the
SH11C motors to able provide up to 430 bar [6235 psi] continuous and 480 bar [6960 psi] peak performance.
Fully laboratory tested and field proven, these units provide maximum efficiency and longlife. Heavy duty bearings permit high radial
and axial loads.
Versatile design includes a variety of port plates, shaft ends and valves packages that will fit the SH11C motors to any application
both industrial and mobile. SH11C motors are available in both ISO and SAE version.
DC5A1G1_0000000 - 01/22
SH11C-M/01
B2 General information - Features
Simbology:
N/bar l/min
C
[lbf/psi]
Load Qmax [U.S. gpm]
Maximum flow
N l/min
Fax max Axial pushing load Qd External drain flow
[lbf] [U.S. gpm]
N Nm/bar
Fax max Axial pulling load Tk Torque costant
[lbf] [lbf.ft/psi]
N Nm
Fq Radial load Tmax Maximum torque at pressure continuous
[lbf] [lbf.ft]
N Nm
Fq max Maximum permissible radial load Tpeak Maximum torque at pressure peak
[lbf] [lbf.ft]
kg·m2 cm3/rev
J Moment of inertia Vg Displacement
[lbf·ft2] [in3/rev]
kg kW
m Weight Pmax Maximum power at pnom
[lbs] [hp]
n max rpm Maximum speed ηhm % Mech-hyd. efficiency
bar
pmax [psi]
Maximum continuous pressure ηv % Volumetric efficiency
bar
ppeak [psi]
Maximum pressure peak
Hydraulic fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15 ÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed, for
different types of viscosity please contact Dana. Viscosities less then 10 cSt are not allowed. A viscosity range of 10 ÷ 15 cSt is
allowed for extreme operating conditions and for short periods only.
Temperature ranges:
The operating temperature of the oil must be within -25ºC÷ 115ºC [-13ºF ÷ 239ºF]. For applications with lower temperatures please
contact Dana.
Filtering:
A correct filtering is essential for long and satisfactory life of axial piston units. In order to ensure a correct functioning of the unit, the
max. permissible contamination class is 21/19/16 according to ISO 4406:1999.
Operating pressure:
The maximum permissible pressure on pressure ports is 430 bar [6235 psi] continuous and 480 bar [6960 psi] peak. If two motors
are connected in series, total working pressure P1+P2 has to be limited 700 bar max. [10150 psi].
P1 P2 P3
DC5A1G1_0000000 - 01/22
SH11C-M/01
General information - Features B3
p
psi bar 160-180 108-125
220 15
210 075-090
200 14
045-055-063
190 13
180
12
020-030
170
11
010-016
160
150 10
Pressure
140
130 9
120 8
110
100 7
90 6
80
70 5
60 4
50
3
40
30 2
20
1
0 1000 2000 3000 4000 5000 6000 7000 8000 n
Speed rpm
Output shaft:
Table is a guide to determine max. permissible loads. Values are calculated in such a way to assure at least 80% of the bearing
operating life where no external load is applied. The published values are related to loads applied in the middle of shaft and in the
least favourable direction.
Fq
+ Fax
- Fax
* : work in progress
1) : in the following table, values of Fq max for the output shafts
When an external side (radial) load is applied to the drive shaft, the bearing life will vary accordingly to the magnitude, location and
direction of the load. The diagram shows how the bearing operating life varies versus the direction of the load. In the diagram 100%
represents the bearing operating life where no external side load is applied to the drive shaft.
DC5A1G1_0000000 - 01/22
SH11C-M/01
B4 General information - Features
120%
Alternating rotation
110%
CW motor φ φ CCW motor
Bearing life (%)
100%
B A
90%
80%
70%
-180 -135 -90 -45 0 45 90 135 180
φ (°)
The bearing operating life increases up to 30% when the load is applied with some peculiar directions
and the maximum increase is dependent on the operating pressure and the nominal size of the unit.
When considering the permissible axial force, the force - transfer direction must be taken in account:
• Pushing axial loads increase the bearing life.
• Pulling axial loads reduce the bearing life (if possible pulling axial loads should be avoided).
Seals:
Seals used on SH11C series are of FKM (Fluoroelastomer). In case of use of special fluids, contact Dana.
Installation:
SH11C series motors can be installed in every position or direction. These axial piston units have separate ports and drain chambers
and so must be always drained. For further details see on the General Information Catalogue, the section “General installation
guidelines”.
Flangeable valves:
Flangeable valves are available for motors both in open and closed loop. For more information see the catalogue Axial Valves.
Flushing valves:
The motors can be equipped with flushing valves.
The mount the flushing valve on motors, it is necessary to use a special port cover. For more information see the catalogue Axial
Valves.
DC5A1G1_0000000 - 01/22
SH11C-M/01
Technical data B5
Size
010* 016* 20 30 045* 55 63 75 90 108 125 160 180
cm3/rev 10.3 16 19.9 31.9 46 56.35 63.26 77.82 86.23 108.4 124.8 163.9 178.1
Displacement Vg [in3/rev] [0.626] [0.976] [1.213] [1.945] [2.807] [3.437] [3.859] [4.747] [5.26] [6.612] [7.613] [9.998] [10.864]
bar 430 430 430 430 430 430 430 430 430 430 430 430 430
Max. pressure pmax [psi] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235]
bar 480 480 480 480 480 480 480 480 480 480 480 480 480
Max. peak pressure ppeak [psi] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960]
Max. speed nmax rpm 8000 8000 6300 6300 5600 5000 5000 4500 4500 4000 4000 3600 3600
l/min 82 128 125 201 257 282 316 350 388 433 500 590 641
Max. flow Qmax [US gpm] [21.66] [33.81] [33] [53.06] [67.89] [74.45] [83.42] [92.4] [102.5] [114.31] [132] [155.76] [169.22]
kW 59 92 90 144 184 202 226 251 278 310 358 423 459
Max. power at pmax Pmax [hp] [79.1] [123.4] [120.6] [192.96] [246.7] [270.68] [302.84] [336.34] [372] [415.4] [479.72] [566.82] [615.06]
Nm/bar 0.16 0.25 0.3 0.5 0.73 0.9 1 1.2 1.4 1.7 2 2.6 2.8
Torque costant Tk [lbf.ft/psi] [0.008] [0.013] [0.015] [0.025] [0.037] [0.045] [0.05] [0.06] [0.07] [0.085] [0.1] [0.13] [0.14]
Nm 71 110 136 218 315 386 433 533 590 742 855 1122 1219
Max. torque at pmax Tmax [lbf.ft] [52.36] [81.13] [100.23] [160.66] [232.33] [284.48] [319.12] [392.82] [435.13] [546.85] [630.13] [826.91] [898.40]
Nm 79 122 152 244 352 431 484 595 659 829 954 1253 1361
Max peak torque at ppeak Tpeak [lbf.ft] [58.27] [89.98] [112.02] [179.82] [260.36] [317.65] [356.71] [438.51] [486.05] [610.97] [703.10] [923.46] [1003.06]
kg·m2 0.0005 0.0005 0.001 0.001 0.004 0.004 0.004 0.007 0.007 0.012 0.012 0.022 0.022
Moment of inertia (3) J [lbf.ft2] [0,0118] [0,0118] [0.0235] [0.0235] [0.094] [0.094] [0.094] [0.1645] [0.1645] [0.2820] [0.2820] [0.5170] [0.5170]
kg 6 6 10 10 18 19 19 23.7 23.7 35 35 48 48
Weight (3) m [lbs] [13.22] [13.22] [22.04] [22.04] [39.68] [41.876] [41.876] [52.23] [52.23] [77.14] [77.14] [105.79] [105.79]
*) Work in progress
3) Approximate values.
4) Average values at 250 bar [3625 psi] with mineral oil at 45°C [113°F] and 35 cSt of viscosity.
(Theorical values, without considering ηhm and ηv approximate values). Peak operations must not exceed 1% of every minute.
A simultaneous maximum pressure and maximum speed not recommended.
DC5A1G1_0000000 - 01/22
SH11C-M/01
B6 SH11C 010-016 Fan motors
SH11C 10-16 cc motors are common in fan application. Typical need of this application are built-in check valve in anti-cavitation
function.
The fan motor can work safely at very high speed without reliability problems thanks to anti-cavitation valve.
When the flow to the motor is shut off and the motor is rotating at high speed, the anti-cavitation valve will open and direct flow to the
motor inlet port. To execute this function, it is necessary that sufficient return port back pressure is available. If the inlet pressure is
insufficient, motor cavitation will be experienced.
A back pressure, in an open circuit, can be created by a counter pressure valve through the line to the tank; if possible, it should be
pilot operated to minimize power losses. A back pressure of about 8÷10 bar is sufficient in most applications.
Ordering code due to the built-in anti-cavitation valve, the direction of rotation of the motor must be specified when ordering the
motor.
Typical applications
• Head exchangers
• Air seeders
• Blowers
A - B Service ports
T1 - T2 Drain ports
DC5A1G1_0000000 - 01/22
SH11C-M/01
Ordering code B7
The following alphanumeric codes system has been developed to identify all of the configuration options for the SH11C motors. Use
the model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering.
We advise to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Special feature
Flushing valve
Displacement
Mount flange
Valve feature
Direction of
Port cover
Shaft end
Painting
rotation
Version
Series
Motor
Valve
Seal
S H 1 1 C M 0 3 0 M E O C C M B L M 1 R V V V C D M 0 0 0 0 6 0 3 0 1
1
Series
SH11C Fixed displacement, bent axis, axial piston unit
2
Motor
M Motor
3
Displacement
010* 10.3 cm3/rev [0.626 in3/rev]
4
Version
ME ISO
SE SAE
DC5A1G1_0000000 - 01/22
SH11C-M/01
B8 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
5
Size
Mount flange
010* - 016* 020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
OA ISO 4 holes Ø 80 mm [Ø3.15 in] ME – – – – –
02 SAE-B 2 holes SE – – – – –
05 SAE-C 4 holes – SE SE SE – –
08 SAE-D 4 holes – – – – SE SE
* : work in progress
1) The ME digit means that the flange in only available for the ISO version.
2) The SE digit means that the flange in only available for the SAE version.
DC5A1G1_0000000 - 01/22
SH11C-M/01
Ordering code B9
1 2 3 4 5 6 7 8 9 10 11 12 13 14
6
Size
Shaft end
010* - 016* 020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
Parallel keyed Ø20 mm k6 [0.787 in k6]
CAV ME – – – – –
Key 6x6x30 [0.23x0.23x1.18]
Parallel keyed Ø25 mm k6 [0.984 in k6]
CMB ME – – – – –
Key 8x7x32 [0.31x0.27x1.25]
Parallel keyed Ø25 mm k6 [0.984 in k6]
CBM – ME – – – –
Key 8x7x40 [0.31x0.27x1.57]
Parallel keyed Ø 30 mm k6 [1.181 in k6]
CBN – ME – – – –
Key 8x7x40 [0.31x0.27x1.57]
Parallel keyed Ø 30 mm k6 [1.181 in k6]
CAW – – ME – – –
Key 8x7x50 [0.31x0.27x1.97]
Parallel keyed Ø 35 mm k6 [1.377 in k6]
CBO – – ME–SE – – –
Key 10x8x50 [0.39x031x1.97]
Parallel keyed Ø 40 mm k6 [1.574 in k6]
CBP – – – ME – –
Key 12x8x56 [0.47x0.31x2.204]
Parallel keyed Ø 40 mm k6 [1.574 in k6]
CAK – – – – ME –
Key 12x8x63 [0.47x0.31x2.48]
Parallel keyed Ø 45 mm k6 [1.772 in k6]
CAJ – – – – ME–SE –
Key 14x9x63 [0.55x0.35x2.48]
Parallel keyed Ø 45 mm k6 [1.772 in k6]
CBQ – – – – – ME
Key 14x9x70 [0.55x0.35x2.75]
Parallel keyed Ø 50 mm k6 [1.968 in k6]
CAX – – – – – ME–SE
Key 14x9x70 [0.55x0.35x2.75]
Parallel keyed Ø 35 mm k6 [1.377 in k6]
CAY – – – ME – –
Key 10x8x56 [0.39x0.31x2.204]
SAF Splined W20x1.25x30x14x9g DIN 5480 ME – – – – –
* : work in progress
1) The ME digit means that the flange in only available for the ISO version.
2) The SE digit means that the flange in only available for the SAE version.
DC5A1G1_0000000 - 01/22
SH11C-M/01
B10 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
7
Size
Port cover
010* - 016* 020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
VM2 Lateral ports same side – ME–SE ME–SE ME–SE ME–SE ME–SE
* : work in progress
1) The ME digit means that the flange in only available for the ISO version.
2) The SE digit means that the flange in only available for the SAE version.
8
Direction of rotation (viewed from shaft side)
RV Reversible
9
Seal
V FKM
10
Size
Valve
010* - 016* 020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
XXXX None • • • • • •
VCDM VCD/M Pilot assisted overcentre valve – VM2–FM2 VM2–FM2 VM2–FM2 VM2–FM2 VM2–FM2
VCD1 VCD/1 Pilot assisted overcentre valve – – LM2 LM2 LM2 LM2
VCR3 VCR3 Double acting overcentre valve – – VM2–FM2 VM2–FM2 VM2–FM2 VM2–FM2
* : work in progress
• : Available
The valves are available with ISO port cover only, please contact Technical department for SAE version.
The VM2-FM2-LM2 digits means that the valves are only available with VM2-FM2-LM2 port covers.
DC5A1G1_0000000 - 01/22
SH11C-M/01
Ordering code B11
1 2 3 4 5 6 7 8 9 10 11 12 13 14
11
Valve
Valve feature
XXXX VCDM VCD1 VCD2 VCR1 VCR3 VU16 VSD1
• : Available
1) : Not available with VM2 port cover.
Please contact Technical department for valve which requie specific setting.
For the technical specifications see catalogue valves.
DC5A1G1_0000000 - 01/22
SH11C-M/01
B12 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
12
Size
Flushing valve
010* - 016* 020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
XX None • • • • • •
PR Arranged for Flushing Valve – LM2 LM2 LM2 LM2 LM2
06 VSC/F Flushing valve - 6 l/min [1.58 U.S. gpm] – LM2-VM2 LM2-VM2 LM2-VM2 LM2-VM2 LM2-VM2
09 VSC/F Flushing valve - 10.5 l/min [2.77 U.S. gpm] – LM2-VM2 LM2-VM2 LM2-VM2 LM2-VM2 LM2-VM2
15 VSC/F Flushing valve - 15 l/min [3.96 U.S. gpm] – LM2-VM2 LM2-VM2 LM2-VM2 LM2-VM2 LM2-VM2
* : work in progress
• : Available
It is not possible to combine the flushing valves with valve on table 10. For the technical specifications see catalogue valves.
1) The ME digit means that the flange in only available for the ISO version.
2) The SE digit means that the flange in only available for the SAE version.
13
Size
Special feature
010* - 016* 020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
XX None • • • • • •
03 SAE version with ISO port cover – – • (1)
• (2) – –
* : work in progress
• : Available
14
Painting
XX None
01 Painted RAL 9005
DC5A1G1_0000000 - 01/22
SH11C-M/01
Dimensions ISO 4 Bolts flange (OA) SH11C 010-016 ME B13
120.2 [4.73]
29 [1.14] 95 [3.741]
R
11.1 [0.44]
6 [0.24]
S1 Ø100 [3.94]
Ø 79.5 [3.13]
Ø 80 [3.15]
96 [3.78]
40°
A, B: Service line ports
58 [2.28]
R: Air bleed (plugged) - 1/8 G (BSPP)
12 [0.47]
60 [2.36]
7 Port cover
90 [3.54]
34 [1.34] 47.5 [1.87] 48 [1.89]
59.1 [2.33]
76.4 [3.01]
104.2 [4.10]
97.6 [3.84]
Depth
c M22x1.5 M22x1.5
M22x1.5 M22x1.5
20 [0.79] 20 [0.79] Depth
M22x1.5 20 [0.79] Depth 20 [0.79] Depth 46[1.81]
134.7 [5.30] 103.2 [4.06]
20 [0.79] Depth
155.3 [6.11] 157.3 [6.19]
6 Shaft end
Key 6x6x30 UNI 6604 Key 8x7x32 UNI 6604 Spline W25x1.25x30x18x9g Spline W20x1.25x30x14x9g
5 [0.20] DIN 5480 DIN 5480
5 [0.20]
22 [0.87]
30 [1.18] 32 [1.26] 22 [0.87]
22.5 [0.89]
28 [1.10]
M6
M10x1.0
M10x1.0 [0.39]
Ø25 [0.98]
16
6 [0.236]
Ø20 [0.78]
[0.63] 22 [0.87] 16
[0.63]
22 [0.87]
21[0.83] 30 [1.18]
20 [0.79]
20 [0.79]
20 [0.79] 20 [0.79]
60 [2.36] 40 [1.89] 54 [2.13]
60 [2.36]
DC5A1G1_0000000 - 01/22
SH11C-M/01
B14 Dimensions ISO 4 Bolts flange (OB) SH11C 020-030 ME
134 [5.28]
23.2 [0.91] 27 [1.06]
Ø
10.7 [0,42]
8 [0.31] 12 118 [4.64]
R 5[
4.9
2]
S1
S1, S2: Drain ports (1 plugged) - 3/8 G (BSPP)
Ø 100 [3.94]
118 [4.65]
Ø 95 [3.74]
S2
64 [2.25]
7 Port cover
87.4 [3.44]
87.4 [3.44]
127 [5.00]
127 [5] 59 [2.32]
3/4 G [BSPP]
M8
18.24 [0.718]
C
C
3/4 G [BSPP] 173.1 [6.82] 40.49 [1.594]
173.1 [6.82]
VM2 LM2
Detail
Visto da C
C/Detail C Visto Detail
da C/Detail
C C
183.7 [7.23]
191.1 [7.52]
90.2 [3.55]
87.4 [3.44]
119 [4.69]
115 [4.53]
59 [2.32] 1/2” SAE 6000
1/2” SAE 6000
1/2” SAE 6000 1/2” SAE 6000
108.9 [4.29]
4]
59
.
[1
9
18.24 [0.718]
.4
M8
40
40.49 [1.594]
159 [6.26] C 18
.2
M8 4
[0
.7
18
173.1 [6.82] ]
6 Shaft end
Profilo /Spline
Spline
Profilo /Spline
Spline W30x2x30x16x9g DIN 5480
Linguetta
Key/ Key Key W25x1.25x30x18x9g DIN 5480
Linguetta / Key
8x7x40 UNI 6604
8x7x40 UNI 6604
Ø29.6 [1.165]
Ø24.8 [0.976]
28 [1.10]
Ø 25 [0.984]
33 [1.29]
Ø30 [1.181]
M8
M10
M10
M8
DC5A1G1_0000000 - 01/22
SH11C-M/01
Dimensions ISO 4 Bolts flange (OC) SH11C 045-055-063 ME B15
78 [3.07]
70 [2.76]
10 [0.393] 10 [0.393] 150 [5.91]
° 45°
R 45
S1
Ø125 0-0.063 [4.921 00.00248 ]
75.5 [2.97]
79.5 [3.13]
59.5 [2.34]
7 Port cover
109.9 [4.33]
109.9 [4.33]
88.4 [3.48]
155 [6.10]
147 [5.79] 147 [5.79]
58 [2.283] 75 [2.953]
G 1”BSPP G 1”BSPP 3/4” SAE 6000 3/4” SAE 6000
137.8 [5.43]
137.8 [5.43]
A B
23.8 [0.937]
M10 Prof.18
C M10
18 Depth [0.708]
[0.708] Depth
C
50.8 [2.00]
168.8 [6.65]
VM2 LM2
215.3 [8.48]
205 [8.07] VistoDetail C
da C/Detail C 168.8 [6.65]
111.1 [4.37]
Visto da C/Detail
Detail C C
88.4 [3.48]
137.8 [5.43]
A B
Ø19 [0.748]
Ø19 [0.748]
23.8 [0.937]
M10 Prof.18 23
M10
18 Depth [0.708]
[0.708] Depth .8
[0
.9 C
37
176.8 [6.96] C 50.8 [2.00] ]
]0
.0
[2
M10 Prof.18
.8
M10[0.708]
18 Depth [0.708]
Depth
50
6 Shaft end
32 [1.26]
28 1.102
38 1.496
Ø29.6 [1.17]
Ø34.5 [1.36]
33 [1.30]
M10
M12
Ø300.015
M10
+0,000
+0,001
22 [0.87] 22 [0.87]
14.5 [0.57]
Linguetta
Key / Key 32 [1.26] 24 [0.94]
32 1.26
+0.002
+0.018
72 [2.83] 67 [2.64]
DC5A1G1_0000000 - 01/22
SH11C-M/01
B16 Dimensions ISO 4 Bolts flange (OD) SH11C 075-090 ME
85.5 [3.37]
29 [1.14] 155.7 [6.13]
164.8 [6.49]
10 [0.39] 14 [0.55]
R ° 45°
45
12.1 [0.48]
Ø135 0-0.063 [5.512 00.00248 ]
83.1 [3.27]
83 [3.27]
62.8 [2.47]
7 Port cover
LM2 FM2
232.7 [9.16] Visto Detail
da C/Detail
C C 232.7 [9.16]
Visto da C/Detail
Detail C C
183.2 [7.212] 208.5 [8.208]
95.1 [3.744]
116.3 [4.578]
148.5 [5.85]
A B
148.5 [5.85]
5]
Ø25 [0.98]
Ø25 [0.98]
.2
27
27.76 [1.093]
[2
.7
5
6
.1
[1
57
.0
93 C
] C 57.15 [2.25]
VM2
27.76 [1.093]
6 Shaft end
AS 10x8x56 AS 12x8x56
0.0007
0.0007
M12
M16
Ø34.5 [1.36]
Ø39.5 [1.55]
0.018
43 [1.69]
Ø35 0.018
38 [1.49]
M16
M12
Ø40
28 [1.102] 36 [1.41]
28 [1.102] 36 [1.42]
32 [1.26]
37 [1.45]
DC5A1G1_0000000 - 01/22
SH11C-M/01
Dimensions ISO 4 Bolts flange (OE) SH11C 108-125 ME B17
14.7 [0.578]
R
]
Ø2
[6.299 -0.0024
00
[7.8
74]
0
191 [7.52]
Ø1 A, B: Service line ports
7.5
90 [3.543]
R: Air bleed (plugged) - 1/8 G (BSPP)
Ø160 -0.063
[0.6
9]
0
10 [0.39] S2
36.5 [1.44]
59.5 [2.342]
7 Port cover
FM2
265.9 [10.47] Visto Detail
da C/Detail
C C
242.7 [9.555] 202.1 [7.95]
194 [7.64]
1” 1/4 SAE 6000 1” 1/4 SAE 6000
31.75 [1.25]
136.9 [5.389]
A B
166.2 [6.54]
M14 Prof. 19
66.68 [2.625] M14
19 Depth Depth
[0.748] [0.748]
C 99 [3.897]
VM2 LM2
Visto da C/Detail
Detail C C
265.9 [10.47] 1” 1/4 SAE 6000
VistoDetail
da C/Detail
C C
212.8 [8.377]
194 [7.64] 194 [7.64]
1” 1/4 SAE 6000 1” 1/4 SAE 6000 M14 Prof.25
99 [3.897]
M14 Depth [0.984]
25 [0.984] Depth
1” 1/4 SAE 6000
135.7 [5.34]
A
159.6 [6.29]
B
31.75 [1.25]
66 111.9 [4.405]
M14 Prof.19
166.2 [6.54]
A B
Ø32 [Ø1.26]
]
Ø32 [Ø1.26]
25
M14 Depth
19 [0.748] [0.748]
Depth
.6
[2
31
.7
8
66.68 [2.625]
.6
5
C [1
.2
225.3 [8.87] 5]
C
262 [10.31]
6 Shaft end
ProfiloSpline
/ Spline Profilo /Spline
Spline
Linguetta
Key/ Key Linguetta
Key/ Key W40x2x30x18x9g DIN 5480 W45x2x30x21x9g DIN 5480
12x8x63 UNI 6604 14x9x63 UNI 6604
0.002 [Ø1.574 0.00007 ]
0.0007
48.5 [1.91]
Ø39.6 [1.56]
Ø44.5 [1.75]
43 [1.69]
M12
M16
M12
M16
Ø 40 0.018
Ø 45 0.018
23 [0.91] 36 [1.42]
37.4 [1.47] 42 [1.65]
28 [1.10] 36 [1.42]
40 [1.57] 40 [1.57]
40 [1.57] 40 [1.57]
85 [3.35] 90 [3.54]
120 [4.73] 120 [4.73]
DC5A1G1_0000000 - 01/22
SH11C-M/01
B18 Dimensions ISO 4 Bolts flange (OF) SH11C 160-180 ME
200.5 [7.893]
210 [8.27]
25 [0.98]
45°
16.8 [0.66] 45°
R
13.9 [0.547]
-0.0098 ]
0
Ø180 -0.025 [7.087
S1
210 [8.27]
°
113 [4.449]
]
0
.819
4 [8
Ø22
69]
37.2 [1.46] [0.
7.5
S2 Ø1
10 [0.39]
71.8 [2.827]
7 Port cover
LM2 FM2
293.7 [11.56] 293.7 [11.56]
236.5 [9.31] M14 Prof.25 Detail
Visto da C
C/Detail C
Detail
Visto da C C
C/Detail 267.9 [10.55]
M14
25Depth [0.984]
[0.984] Depth 210 [8.27]
1” 1/4 SAE 6000
31.75 [1.25]
129.8 [5.11]
156.2 [6.15]
191.4 [7.54]
191.4 [7.54]
A B
]
25
.6
A B M14 Prof. 19
[2
31
66.68 [2.625]
8
.7 M14
19 Depth [0.748]
[0.748]
.6
5
Ø32 [1.26]
Ø32 [1.26]
66
[1 Depth
.2 C 99 [3.897]
5]
C
VM2
285.7 [11.25]
Detail
Visto da C
C/Detail C
1” 1/4 SAE 6000
194 [7.64]
149.2 [5.87]
31.75 [1.25]
189 [7.32]
A B
M14 Prof.19
66.68 [2.625] M14
19 Depth [0.748]
[0.748] Depth
C
239.7 [9.44] 99 [3.897]
6 Shaft end
0.00007 ]
48.5 [1.91]
53.5 [2.11]
Ø44.5 [1.75]
Ø49.8 [1.96]
0.0007
0.0007
M16
M16
M16
M16
[1.968
Ø 45 0.018
0.018
0.002
36 [1.42] 36 [1.42]
Ø 50
DC5A1G1_0000000 - 01/22
SH11C-M/01
Dimensions SAE C 2 Bolts flange (OA) SH11C 010-016 SE B19
11.1 [0.44]
39.3 [1.55] R
S1
Ø101 .6 [4]
°
40
S1, S2: Drain ports (1 plugged) - 3/4”-16 UNF 2B
A, B: Service line ports
Ø14 [0.55]
R: Air bleed (plugged) - 7/16”-20 UNF 2B
59 [2.32]
9.7 [0.38] S2
12 [0.47]
73.3 [2.89]
7 Port cover
LM1
190.7 [7.51]
Visto Detail
da C/Detail
C C
59.1 [2.33]
90 [3.54]
104.2 [4.10]
C
1”1/16 12-2B
146.8 [5.78] 20 [0.79]
[0.79] Prof./Depth
Depth
6 Shaft end
Splined
S05 shaft
Spline
Profilo / Spline
D.P. 16/32 Z13 ANSI B92.1 26 [1.02]
Ø5/16-18 UNC
19
[0.75]
34 [1.34]
41.9 [1.65]
DC5A1G1_0000000 - 01/22
SH11C-M/01
B20 Dimensions SAE C 4 Bolts flange (O5) SH11C 020-030 SE
146 [5.75]
154.3 [6.08]
45°
12.7 [0.50] 20 [0.79] Ø1 45°
14.5 [0.57]
6 2[
6.3
8]
]
-0.002
S1
146 [5.75]
0
S2
67 [2.64]
Ø14
81 [3.19]
.3 [
.560
]
7 Port cover
LM2 FM2
208.2 [8.20]
Visto da C/Detail
Detail C C 208.2 [8.20] Visto da C/Detail
Detail C C
169.1 [6.66]
69.7 [2.75]
87.4 [3.44]
119 [4.69] 1/2” SAE 6000
127 [5.00]
59 [2.32]
108.9 [4.29]
108.9 [4.29]
]
94
.5
[1
9
.4
40
18.24 [0.718]
C 5/16”-18 UNC 2B
18 190.2 [7.49]
.2 40.49 [1.594]
4
5/16”-18 UNC 2B [0
.7
18
]
VM2
Visto Detail
da C/Detail
C C
200.8.7 [7.91] 1/2” SAE 6000
90.2 [3.55]
115 [4.53]
59 [2.32]
18.24 [0.718]
5/16”-18 UNC 2B
C 40.49 [1.594]
176.1 [6.93]
6 Shaft end
6.35x6.2x28
7/16”-14 UNC-2B
[0.25x0.24x1.10]
Ø21.8 [0.858]
Ø31.2 [1.228]
24.9 [0.98]
5/16”-18 UNC 2B
Ø22.22 [0.874]
28 [1.10] 22 [0.86]
26 [1.02] 32 [1.26] 31 [1.22]
31 [1.22] 56 [2.20]
41.1 [1.62]
DC5A1G1_0000000 - 01/22
SH11C-M/01
Dimensions SAE C 4 Bolts flange (O5) SH11C 045-055-063 SE B21
163.2 [6.43]
12.7 [0.50] 34.1 [1.34] 146 [5.75]
73 [2.87]
17.5 [0.69] 45°
45°
15.5 [0.61]
R
]
]
[0.56
-0.002
S1
.3 S1, S2: Drain ports (1 plugged) - 1” 1/16 - 12 UN 2B
Ø14
0
[5.00
8]
Ø 127
6.3
S2 2[
73 [2.87]
6
79.5 [3.13]
Ø1
83.6 [3.29]
7 Port cover
LM2 FM2
250.4 [9.86] Detail
Visto da C
C/Detail C
250.4 [9.86]
192.9 [7.60] 218.6 [8.61] 155 [6.10]
88.4 [3.48]
109.9 [4.33]
Visto da C/Detail
Detail C C 147 [5.79]
147 [5.79] 75 [2.953]
3/4” SAE 6000 3/4” SAE 6000 3/4” SAE 6000
3/4” SAE 6000
147.9 [5.82]
147.9 [5.82]
A B
Ø19 [0.748]
Ø19 [0.748]
23.8 [0.937]
23
.8
[0
.9 C 50.8 [2.00]
37 C
]
3/8”-16 UNC 2B Prof.18
0]
.0
3/8”-16
18 UNCDepth
[0.708] 2B [0.708]
[2
3/8”-16 UNC
20 [0.79] 2B Depth [0.79]
Depth
50
VM2
229.1 [9.02] Visto Detail
da C/Detail
C C
147 [5.79]
75 [2.953]
3/4” SAE 6000 3/4” SAE 6000
111.1 [4.37]
132.2 [5.21]
23.8 [0.937]
C
199.2 [7.84] 50.8 [2.00]
3/8”-16 UNC 2B Prof.18
18 [0.708] Depth
6 Shaft end
Ø31.2 [1.23]
-0.0019 ]
3/8" 16 UNC 2B
+0.002 1,378 +0.00008
0
31.5 [1.24]
Ø 31.75 0-0.05 [1.25
DC5A1G1_0000000 - 01/22
SH11C-M/01
B22 Dimensions SAE C 4 Bolts flange (O5) SH11C 075-090 SE
12.7 [0.50] 180.9 [7.122]
146 [5.75]
73 [2.87]
39 [1.535]
45°
20 [0.79] 45°
13.3 [0.523]
R
]
-0.002
S1
°
0
40
Ø162
0
]
[0.56
Ø 127
.3
Ø14
73 [2.87]
87.7 [3.452]
S2
93 [3.661]
7 Port cover
LM2 FM2
256.9 [10.11] 256.9 [10.11]
Visto Detail C
da C/Detail C
207.4 [8.165] Visto Detail
da C/Detail
C C 232.7 [9.161]
95.1 [3.744]
174 [6.85]
166 [6.54] 166 [6.54]
84 [3.307]
1” SAE 6000 1” SAE 6000
1” SAE 6000 1” SAE 6000
116.3 [4.578]
148.5 [5.85]
148.5 [5.85]
5]
A B
.2
27
[2
27.76 [1.093]
Ø25 [0.98]
Ø25 [0.98]
.7
5
6
.1
[1
57
.0
93 C C
] 57.15 [2.25]
7/16”-14 UNC 2B Prof.18
7/16”-14 UNC 2B Prof.18
7/16”-14 UNC
18 [0.708] 2B Depth [0.709]
Depth
7/16”-14
18 UNC
[0.708] 2B Depth [0.709]
Depth
VM2
249.5 [9.82]
Visto Detail
da C/Detail
C C
166 [6.54]
84 [3.307]
1” SAE 6000 1” SAE 6000
124.5 [4.901]
144.4 [5.69]
27.76 [1.093]
C 57.15 [2.25]
216.4 [8.519]
7/16”-14 UNC 2B Prof.18
7/16”-14
18 UNC
[0.708] 2B Depth [0.748]
Depth
6 Shaft end
Spline
Profilo / Spline 66,5 [2.62] Spline
Key
D.P. 12/24 Z14 ANSI A 11.11 x 9.2 x 60 D.P.16/32 Z21
B92.1 a 1976 ANSI B92.1a 1976
3/8”-16 UNC-2B
3/8" 16 UNC 2B
Ø31.15 [1.22]
-0,0020
49,15 [1.94]
1/2” 20 UNF
32 [1.26]
0
1,75
39.6 [1.56]
-0,05
36 [1.42]
0
Ø 44,45
DC5A1G1_0000000 - 01/22
SH11C-M/01
Dimensions SAE D 4 Bolts flange (O8) SH11C 108-125 SE B23
215.8 [8.496]
200 [7.87]
12.7 [0.50] 49.6 [1.952]
45°
24.9 [0.98] 45°
R
15.3 [0.602]
Ø2
28.
6 [9
.00
]
]
[6.00-0.0019
200 [7.87]
A, B: Service line ports
93 [3.661]
Ø20
.6 [0 R: Air bleed (plugged) - 7/16”-20 UNF
Ø152.4 -0.05
.81]
0
S2
59.5 [2.342]
7 Port cover
LM2 FM2
297.9 [11.73] Visto da C/Detail
Detail C C Visto Detail C
da C/Detail C
244.9 [9.641] 1” 1/4 SAE 6000 297.9 [11.73]
274.8 [10.818] 1” 1/4 SAE 6000
111.8 [4.401]
31.75 [1.25]
166.2 [6.54]
136.9 [5.389]
]
A
25
B A B
166.2 [6.54]
.6
Ø32 [1.26]
[2
Ø32 [1.26]
8
31
.6
.7
66
5 66.68 [2.625]
[1
.2 C
5] 99 [3.897]
C
1/2”-13 UNC 2B Prof.25 1/2”-13 UNC 2B Prof.19
1/2”-13 UNCDepth
25 [0.984] 2B Depth [0.984] 1/2”-13 UNC
19 [0.748] 2B Depth [0.748]
Depth
VM2
294 [11.58]
Visto da C/Detail
Detail C C
194 [7.64]
1” 1/4 SAE 6000 99 [3.897] 1” 1/4 SAE 6000
A B
135.7 [5.34]
31.75 [1.25]
159.8 [6.29]
66.68 [2.625]
6 Shaft end
Ø43.9 [1.73]
[1.748 0+0.0019]
1/2” 20 UNF
1/2” 20 UNF
1/2” 20 UNF
Ø38 [1.50]
7.86 [0.31]
+0.05
DC5A1G1_0000000 - 01/22
SH11C-M/01
B24 Dimensions SAE D 4 Bolts flange (O8) SH11C 160-180 SE
200 [7.87]
232 [9.134]
48.9 [1.925] 45°
45°
12.7 [0.50]
R
13.2 [0.519]
[6.087 -0.0019 ]
200 [7.87]
A, B: Service line ports
°
40
113 [4.449]
.6 [9.0
-0.05
Ø228
0
Ø152.4
.83]
Ø21 [0
25 [0.98] S2
103.9 [4.09]
7 Port cover
LM2 FM2
325.8 [12.83] 325.8 [12.83]
Detail C
Visto da C/Detail C
268.6 [10.58]
1” 1/4 SAE 6000
300 [11.81] Visto Detail
da C/Detail
C C
1” 1/4 SAE 6000
31.75 [1.25]
156.2 [6.15]
188.6 [7.43]
A B
188.6 [7.43]
Ø32 [Ø1.26]
Ø32 [Ø1.26]
]
25
A B
.6
[2
31
8
.7
.6
5
66
[1 66.68 [2.625]
.2 C C
5]
99 [3.897]
1/2”-13 UNC 2B Prof.19 1/2”-13 UNC 2B Prof.19
19 1/2”-13
[0.748]UNC 2B Depth [0.748]
Depth 1/2”-13 UNC
19 [0.748] 2B Depth [0.748]
Depth
VM2
317.8 [12.51]
Visto da C/Detail
Detail C C
1” 1/4 SAE 6000
194 [7.64]
149.2 [5.87]
31.75 [1.25]
186 [7.32]
A B
66.68 [2.625]
C
99 [3.897]
271.8 [10.70]
6 Shaft end
C18 Parallel
Albero
cilindrico
keyed shaft S15 Splined
Albero
scanalato
shaft
Linguetta
Key/ Key
Linguetta
11.11x9.2x60 [0.43x0.36x2.36] Spline
Profilo / Spline
Profilo
D.P. 8/16 Z13 ANSI
36 [1.42] B92.1 a 1976
49.1 [1.94]
Ø43.9 [Ø1.73]
1/2” 20 UNF
1/2” 20 UNF
+0.0019]
0
Ø44.4 0+0.05 [1.748
DC5A1G1_0000000 - 01/22
SH11C-M/01
Other caratteristics B25
A C
D
B
Flushing valve Arranged for flushing valve
(06-09-15) (PR)
ME SE
010 020 045-055 075 108 160 010 020 055 075 108 160
016 030 063 090 125 180 016 030 063 090 125 180
mm 225 245.7 259.4 294.3 319.6 242 269.8 283.5 326.4 351.7
A [in]
–
[8.85] [9.67] [10.21] [11.58] [12.58]
–
[9.52] [10.62] [11.16] [12.85] [13.85]
mm 130 152.8 159.1 179.9 199.1 130 152.8 159.1 179.8 199.1
B [in]
–
[5.11] [6.01] [6.26] [7.08] [7.84]
–
[5.11] [6.01] [6.26] [7.08] [7.84]
mm 204 225.7 239.4 274.3 299.6 221 204 263.5 306.4 331.7
C [in]
–
[8.03] [8.88] [9.42] [10.79] [11.79]
–
[8.70] [9.83] [10.37] [12.06] [13.05]
mm 120 142.8 149.1 169.9 189.1 120 142.8 149.1 169.8 189.1
D [in]
–
[4.72] [5.62] [5.87] [6.68] [7.44]
–
[4.72] [5.62] [5.87] [6.68] [7.44]
A
B
Flushing valve
(06-09-15)
ME SE
010 020 045-055 075 108 160 010 020 055 075 108 160
016 030 063 090 125 180 016 030 063 090 125 180
mm 211 239.2 258.8 298.8 313.2 229 263.3 282.9 330.8 345.3
A [in]
–
[8.31] [9.41] [10.18] [1.76] [12.33]
–
[9.01] [10.36] [11.13] [13.02] [13.59]
mm 173 193.6 205.2 218.2 231.7 173 193.6 205.2 218.2 231.7
B [in]
–
[6.81] [7.62] [8.08] [8.59] [9.12]
–
[6.81] [7.62] [8.08] [8.59] [9.12]
DC5A1G1_0000000 - 01/22
SH11C-M/01
B26 Other caratteristics
Clockwise Counterclockwise
B B
97.6 [3.84]
A A
103.2 [4.06]
157.3 [6.19]
T1 T1
T2 T2
Clockwise Counterclockwise
B B
97.6 [3.841]
A A
116.3 [4.581]
169.4 [6.668]
T1 T1
B B
DC5A1G1_0000000 - 01/22
SH11C-M/01
Other caratteristics B27
S1 S1
S2 S2
For the SH11C is possible to request the drain plug reversed compared to standard.
If it is necessary in this configuration, to specify in the purchase order the value “RD” (see position 13 of ordering code).
B
A
ME SE
020 045-055 075 108 160 020 045-055 075 108 160
030 063 090 125 180 030 063 090 125 180
A mm 61.5 56.5 63 74 74.5 78.5 81 88 106 107.5
[inch] [2.42] [2.22] [2.48] [2.91] [2.93] [3.09] [3.18] [3.46] [4.17] [4.23]
B mm 57 68.5 71.7 77.4 85 57 68.5 71.7 77.4 85
[inch] [2.24] [2.69] [2.82] [3.04] [3.34] [2.24] [2.69] [2.82] [3.04] [3.34]
Size
020 045-055 075 108 160
030 063 090 125 180
Number of pulses per revolution 38 47 53 59 67
DC5A1G1_0000000 - 01/22
SH11C-M/01
DC5A1G1_0000000 - 01/22
SH11CR - Plug-in fixed displacement motors for gearbox C1
Index
SH11C 020 19.9 [1.213] 125 [33] 430 [6235] 480 [6960]
SH11C 030 31.9 [1.945] 201 [53.06] 430 [6235] 480 [6960]
SH11C 055 56.35 [3.437] 282 [74.45] 430 [6235] 480 [6960]
SH11C 063 63.26 [3.859] 316 [83.42] 430 [6235] 480 [6960]
SH11C 075 77.82 [4.747] 350 [92.4] 430 [6235] 480 [6960]
SH11C 090 86.23 [5.26] 388 [102.5] 430 [6235] 480 [6960]
SH11C 108 108.4 [6.612] 433 [114.31] 430 [6235] 480 [6960]
SH11C 125 124.8 [7.613] 500 [132] 430 [6235] 480 [6960]
SH11C 160 163.9 [9.998] 590 [155.76] 430 [6235] 480 [6960]
SH11C 180 178.1 [10.864] 641 [169.22] 430 [6235] 480 [6960]
SH11CR series are a family of fixed displacement motors, bent axis piston design for operation in both open and closed circuit.
SH11CR series motors are mainly intended for installation in mechanical gearboxes such as track drive and winches gear boxes.
The proven design incorporating the lens shape valve plate, the high quality components and manufacturing tecniques make the
SH11CR series motors able to provide up to 430 bar [6235 psi] continuos and 480 bar [6960 psi] peak performance.
Fully laboratory tested and field proven, these motors provide maximum efficiency and long life. Heavy duty bearings permit high
radial and axial loads.
Flangeable valves, both for open and closed circuit, enable SH11CR series motors to meet the requirements of the most different
types of applications.
DC5A1G1_0000000 - 01/22
SH11CR-M/01
C2 General information - Features
Simbology:
N/bar l/min
C
[lbf/psi]
Load Qmax [U.S. gpm]
Maximum flow
N l/min
Fax max Axial pushing load qd External drain flow
[lbf] [U.S. gpm]
N Nm/bar
Fax max Axial pulling load Tk Torque costant
[lbf] [lbf.ft/psi]
N Nm
Fq Radial load Tmax Maximum torque at pressure continuous
[lbf] [lbf.ft]
N Nm
Fq max Maximum permissible radial load Tpeak Maximum torque at pressure peak
[lbf] [lbf.ft]
kg·m2 cm3/rev
J Moment of inertia Vg Displacement
[lbf·ft2] [in3/rev]
kg kW
m Weight Pmax Maximum power at pnom
[lbs] [hp]
n max rpm Maximum speed ηhm % Mech-hyd. efficiency
bar
pmax [psi]
Maximum continuous pressure ηv % Volumetric efficiency
bar
ppeak [psi]
Maximum pressure peak
Hydraulic fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15 ÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed, for
different types of viscosity please contact Dana. Viscosities less then 10 cSt are not allowed. A viscosity range of 10 ÷ 15 cSt is
allowed for extreme operating conditions and for short periods only.
Temperature ranges:
The operating temperature of the oil must be within -25ºC÷ 115ºC [-13ºF ÷ 239ºF]. For applications with lower temperatures please
contact Dana.
Filtering:
A correct filtering is essential for long and satisfactory life of axial piston units. In order to ensure a correct functioning of the unit, the
max. permissible contamination class is 21/19/16 according to ISO 4406:1999.
Operating pressure:
The maximum permissible pressure on pressure ports is 430 bar [6235 psi] continuous and 480 bar [6960 psi] peak. If two motors
are connected in series, total working pressure P1+P2 has to be limited 700 bar max. [10150 psi].
P1 P2 P3
DC5A1G1_0000000 - 01/22
SH11CR-M/01
General information - Features C3
p
psi bar 160-180 108-125
220 15
210 075-090
200 14
045-055-063
190 13
180 020-030
12
170
160 11
150
10
Pressure
140
130 9
120 8
110
100 7
90 6
80
70 5
60 4
50
40 3
30 2
20
1 n
0 1000 2000 3000 4000 5000 6000 7000 rpm
Speed
Output shaft:
The service life of the shaft seal is influenced by the speed of rotation of the motor and by case pressure. It’s recommended not to
exceed the value of 10 bar [145 psi], at reduced speed please see the diagram. Instantaneous pressure spikes (t<0.1 sec) up to
15 bar [217.5 psi] are permitted.
Seals:
Seals used on standard SH11CR series axial piston motors are made by FKM seals (Fluoroelastomer). In case of use of special
fluids, contact Dana.
Installation:
SH11CR motors can be installed in various position and directions; however, installation in vertical position with shaft towards upper
is not allowed. These axial piston units have separated ports and drain chambers and so must be always drained. For further detail
see at General installation guidelines.
DC5A1G1_0000000 - 01/22
SH11CR-M/01
C4 General information - Features
Flangeable valves:
Flangeable valves are available for motors both in open and closed loop. For more information see the catalogue Axial Valves.
Flushing valves:
The motors can be equipped with flushing valves.
The mount the flushing valve on motors, it is necessary to use a special port cover. For more information see the catalogue Axial
Valves.
Relation between direction of rotation and direction of flow:
The relation between direction of rotation of shaft and direction of flow in SH11CR piston units is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH11CR-M/01
Technical data C5
Size
020 030 045* 055 063 075 090 108 125 160 180
cm3/rev 19.9 31.9 46 56.35 63.26 77.82 86.23 108.4 124.8 163.9 178.1
Displacement Vg [in3/rev] [1.213] [1.945] [2.807] [3.437] [3.859] [4.747] [5.26] [6.612] [7.613] [9.998] [10.864]
bar 430 430 430 430 430 430 430 430 430 430 430
Max. pressure pmax [psi] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235]
bar 480 480 480 480 480 480 480 480 480 480 480
Max. peak pressure ppeak [psi] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960]
Max. speed nmax rpm 6300 6300 5600 5000 5000 4500 4500 4000 4000 3600 3600
l/min 125 201 257 282 316 350 388 433 500 590 641
Max. flow Qmax [US gpm] [33] [53.06] [67.89] [74.45] [83.42] [92.4] [102.5] [114.31] [132] [155.76] [169.22]
kW 90 144 184 202 226 251 278 310 358 423 459
Max. power at pmax Pmax [hp] [120.6] [192.96] [246.7] [270.68] [302.84] [336.34] [372] [415.4] [479.72] [566.82] [615.06]
Nm/bar 0.3 0.5 0.73 0.9 1 1.2 1.4 1.7 2 2.6 2.8
Torque costant Tk [lbf.ft/psi] [0.015] [0.025] [0.037] [0.045] [0.05] [0.06] [0.07] [0.085] [0.1] [0.13] [0.14]
Nm 136 218 315 386 433 533 590 742 855 1122 1219
Max. cont. torque at pmax Tmax [lbf.ft] [100.23] [160.66] [232.33] [284.48] [319.12] [392.82] [435.13] [546.85] [630.13] [826.91] [898.40]
Nm 152 244 352 431 484 595 659 829 954 1253 1361
Max peak torque at ppeak Tpeak [lbf.ft] [112.02] [179.82] [260.36] [317.65] [356.71] [438.51] [486.05] [610.97] [703.10] [923.46] [1003.06]
kg·m2 0.001 0.001 0.004 0.004 0.004 0.007 0.007 0.012 0.012 0.022 0.022
Moment of inertia (2) J [lbf.ft2] [0.0235] [0.0235] [0.094] [0.094] [0.094] [0.1645] [0.1645] [0.2820] [0.2820] [0.5170] [0.5170]
kg 10 10 18 19 19 23.7 23.7 35 35 48 48
Weight (2) m [lbs] [22.04] [22.04] [39.68] [41.876] [41.876] [52.23] [52.23] [77.14] [77.14] [105.79] [105.79]
* : work in progress
(Theorical values, without considering ηhm and ηv approximate values). Peak operations must not exceed 1% of every minute. A
simultaneous maximum pressure and maximum speed not recommended.
Notes:
1) Approximate values.
2) Average values at 250 bar [3625 psi] with mineral oil at 45°C [113°F] and 35 cSt of viscosity.
DC5A1G1_0000000 - 01/22
SH11CR-M/01
C6 Ordering code
The following alphanumeric codes system has been developed to identify all of the configuration options for the SH11CR series. Use
the model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering.
We advise to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Special feature
Flushing valve
Displacement
Mount flange
Valve feature
Direction of
Port cover
Shaft end
Painting
rotation
Version
Series
Motor
Valve
Seal
SH11CR M 030 GE OH SAG VM2 RV V VCDM 000 06 RD 01
1
Series
SH11CR Fixed displacement, bent axis, axial piston unit
2
Motor
M Motor
3
Displacement
020 20 cm3/rev [1.22 in3/rev]
030 30 cm3/rev [1.83 in3/rev]
045* 46 cm /rev
3
[2.807in3/rev]
055 55 cm3/rev [3.355 in3/rev]
063 63 cm /rev
3
[3.843 in3/rev]
075 75 cm3/rev [4.575 in3/rev]
090 90 cm3/rev [5.49 in3/rev]
108 108 cm /rev 3
[6.588 in3/rev]
125 125 cm3/rev [7.625 in3/rev]
160 160 cm /rev 3
[9.76 in3/rev]
180 180 cm3/rev [10.98 in3/rev]
* : work in progress
4
Version
GE ISO 3019-2 metric
DC5A1G1_0000000 - 01/22
SH11CR-M/01
Ordering code C7
1 2 3 4 5 6 7 8 9 10 11 12 13 14
5
Displacement
Mount Flange
020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
OH 2 holes Ø 135 mm [Ø 5.315 in] • – – – –
OL 2 holes Ø 160 mm [Ø 6.299 in] – • – – –
OM 2 holes Ø 190 mm [Ø 7.480 in] – – • – –
ON 2 holes Ø 200 mm [Ø 7.874 in] – – – • •
• : Available
* : Work in progress
6
Displacement
Shaft end
020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
Port cover
8
Direction of rotation (viewed from shaft side)
RV Reversible
9
Seal
V FKM
DC5A1G1_0000000 - 01/22
SH11CR-M/01
C8 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
10
Displacement
Valve
020 - 030 045 - 055* - 063 075 - 090 108 - 125 160 - 180
XXXX None • • • • •
VCDM VCD/M Pilot assisted overcentre valve VM2 VM2–FM2 VM2 VM2 VM2
VCD1 VCD/1 Pilot assisted overcentre valve – LM2 LM2 LM2 LM2
VCR3 VCR3 Double acting overcentre valve – VM2 VM2 VM2 VM2
• : Available
* : Work in progress
1) The VM2 digit means that the valve is only available with VM2 port cover.
2) The LM2 digit means that the valve is only available with LM2 port cover.
11
Valve
Valve feature
XXXX VCDM VCD1 VCD2 VCR1 VCR3
DC5A1G1_0000000 - 01/22
SH11CR-M/01
Ordering code C9
1 2 3 4 5 6 7 8 9 10 11 12 13 14
12
Flushing valve
XX None •
PR Arranged for Flushing Valve LM2
• : Available
* : Work in progress
It is not possible to combine the flushing valves with valve on table 10.
For the technical specifications see catalogue valves.
1) The LM2-VM2 digit means that the valve is only available with LM2 and VM2 port cover.
13
Special feature
XX None
14
Painting
XX None
01 Painted RAL 9005
02 Painted RAL 5015
DC5A1G1_0000000 - 01/22
SH11CR-M/01
C10 Dimensions 2 Bolts flange (OH) SH11CR 020-030
187.5 [0.74]
71 [2.80]
87.1 [3.43]
160 [6.30]
15 [0.59] 72.8 [2.866]
Ø14 [0.55]
S1
S1, S2: Drain ports (1 plugged) - 3/8 G (BSPP)
Ø135 h6 [5.31]
Ø94 [3.70]
92 [3.622]
13.7 [0.539]
OR 2-250
80 [3.15]
S2
15 [0.59]
7 Port cover
VM2
Detail
Visto da C
C/Detail C
119.9 [4.72]
115 [4.53]
59 [2.32]
1/2” SAE 6000 1/2” SAE 6000
A B
90.2 [3.55]
M8 Prof.18
18.24 [0.718]
M8[0.708]
18 Depth [0.708]
Depth.
40.49 [1.594]
95.2 [3.75]
C
LM2
127.3 [5.01]
88.2 [3.47]
Visto Detail C
69.7 [2.75]
da C/Detail C
119 [4.69]
]
94
.5
[1
9
.4
40
C
18
.2
4
[0
.7
18
]
6 Shaft end
Splined Splined
SAG shaft SAI shaft
Spline / Spline
Profilo Spline
Profilo / Spline
W25x1.25x30x18x9g DIN 5480 W30x2x30x14x9g DIN 5480
88.9 [3.50]
Ø29.6 [1.17]
Ø24.8 [0.976]
M10
M8
22 [0.87]
22 [0.87]
30 [1.18]
28 [1.10]
88.8 [3.50]
121.9 [4.80]
123.8 [4.87]
DC5A1G1_0000000 - 01/22
SH11CR-M/01
Dimensions 2 Bolts flange (OL) SH11CR 045-055-063 C11
90 [3.54] 83 [3.267]
234.3 [9.22]
20.5 [0.807]
15 [0.59]
200 [7.874]
18 [0.71]
Ø160 0-0.025 [6.299 0-0.0009 ]
104 [4.094]
OR 2-258
S2
18.8 [0.74]
7 Port cover
VM2
144.7 [5.69] Visto Detail
da C/Detail
C C
147 [5.79]
75 [2.953]
3/4” SAE 6000 3/4” SAE 6000
111.1 [4.37]
A B
M10 Prof.18
23.8 [0.937]
M10[0.708]
18 Depth [0.708]
Depth
C 50.8 [2.00]
116.5 [4.59]
LM2
155 [6.10]
147 [5.79]
3/4” SAE 6000 3/4” SAE 6000
137.8 [5.43]
A B
Ø19 [0.748]
Ø19 [0.748]
23
.8
[0
.9
37 C
]
0]
.0
M10 Prof.18
[2
.8
M10
18 Depth [0.708]
[0.708] Depth
50
6 Shaft end
Splined Splined
SAI shaft SAM shaft
Spline
Profilo / Spline
W30x2x30x14x9g DIN 5480 Spline
Profilo / Spline
W35x2x30x16x9g DIN 5480
Ø29.6 [1.17]
Ø34.5 [1.36]
M10
M12
22 [0.87]
28 [1.10]
24 [0.94]
92.3 [3.63] 32 [1.26]
127.3 [5.01] 92.3 [3.63]
132.3 [5.21]
Maximum working pressure for 063 displacement: 300 bar [4350 psi]
DC5A1G1_0000000 - 01/22
SH11CR-M/01
C12 Dimensions 2 Bolts flange (OM) SH11CR 075-090
106 [4.17] 82 [3.23]
15 [0.59]
259 [10.20]
13.9 [0.55]
224 [8.82]
-0.0011 ]
22 [0.87]
S1
97.7 [3.85]
Ø140.3 [5.52]
0
40°
121 [4.76]
110 [4.33]
OR 2-262
S2
17.1 [0.67]
7 Port cover
VM2
147.6 [5.81]
Detail
Visto da C
C/Detail C
84 [3.307]
1” SAE 6000 1” SAE 6000
122.7 [4.83]
A B
27.76 [1.093]
M12 Prof.19
M12[0.748]
19 Depth [0.748]
Depth
57.15 [2.25]
114.4 [4.503]
LM2
154.8 [6.09]
166 [6.54]
A
148.5 [5.85]
B
Ø25 [0.98]
Ø25 [0.98]
5]
.2
27
[2
.7
5
6
.1
[1
57
.0
93
] C
M12 Prof.18
M12[0.708]
18 Depth [0.708]
Depth
6 Shaft end
Splined Splined
SAM shaft SAO shaft
Spline / Spline
Profilo
W35x2x30x16x9g DIN 5480 Spline
Profilo / Spline
W40x2x30x18x9g DIN 5480
Ø34.2 [1.34]
39.5 [1.55]
M16
M12
36 [1.42]
28 [1.10] 37 [1.45]
32 [1.26] 110 [4.33]
110 [4.33]
155 [6.10]
150 [5.905]
DC5A1G1_0000000 - 01/22
SH11CR-M/01
Dimensions 2 Bolts flange (ON) SH11CR 108-125 C13
15 [0.59]
22 [0.87]
103 [4.06]
Ø200 0-0.029 [7.874 0-0.0011 ]
S1
S1, S2: Drain ports (1 plugged) - 1/2 G (BSPP)
152.3 [6.00]
40°
116 [4.57]
125 [4.921]
OR 2-264
S2
19.6 [0.771]
7 Port cover
VM2
179.4 [7.06] Visto Detail C
da C/Detail C
194 [7.64]
1”1/4” SAE 6000 1”1/4 SAE 6000
99 [3.897]
A B
31.75 [1.25]
135.7 [5.342]
159.8 [6.29]
M14 Prof.19
M14 Depth [0.748]
66.68 [2.625]
143 [5.629]
LM2
183.3 [7.22] Visto da C/Detail
Detail C C
130.3 [5.129]
194 [7.64]
A
166.2 [6.54]
B
Ø32 [1.26]
Ø32 [1.26]
]
25
.6
[2
31
8
.7
.6
5
66
[1
.2
5] C
M14 Prof.25
M14
25 Depth [0.984]
[0.984] Depth
6 Shaft end
Splined Splined
SAO shaft SAP shaft
Spline
Profilo / Spline
Spline
Profilo / Spline
W40x2x30x18x9g DIN 5480
W45x2x30x21x9g DIN 5480
Ø44.5 [1.75]
M12
Ø39.6 [1.56]
M16
23 [0.91]
37.4 [1.47] 36 [1.41]
122.5 [4.82] 42 [1.65]
167.5 [6.60] 122.5 [4.82]
172.5 [6.79]
Maximum working pressure for 125 displacement: 300 bar [4350 psi]
DC5A1G1_0000000 - 01/22
SH11CR-M/01
C14 Dimensions 2 Bolts flange (ON) SH11CR 160-180
119 [4.70] 117.1 [4.61] 286 [11.26]
15 [0.59] 250 [9.842]
13.2 [0.519]
[7.874 0-0.0011 ]
104 [4.09]
S1
171.6 [6.76]
87
[0.
116 [4.57]
R: Air bleed (plugged) - 1/8 G (BSPP)
147 [5.787]
0
2
Ø2
OR 2-264
S2
23 [0.905]
7 Port cover
VM2
202.9 [7.99]
Detail
Visto da C
C/Detail C
194 [7.64]
1”1/4 SAE 6000 1”1/4 SAE 6000
31.75 [1.25]
149.2 [5.874]
186 [7.32]
A B
M14 Prof.19
66.68 [2.625] M14
19 Depth [0.748]
[0.748] Depth.
C 99 [3.897]
156.9 [6.177]
LM2
210.9 [8.30]
153.7 [6.051]
Visto Detail
da C/Detail
C C
M14 Prof.25 202 [7.95]
M14 Depth [0.984]
25 [0.984] Depth.
A B
Ø32 [1.26]
]
Ø32 [1.26]
25
.6
[2
8
.6
66
31
.7
5
[1 C
.2
5]
6 Shaft end
Splined Splined
SAP
CAK Parallel
shaftshaft
keyed SAR shaft
Spline
Profilo / Spline Spline
Profilo / Spline
W45x2x30x21x9g DIN 5480
W50x2x30x24x9g DIN 5480
M16
Ø44.5 [1.75]
Ø48.8 [1.96]
M16
36 [1.41]
42 [1.65] 36 [1.41]
DC5A1G1_0000000 - 01/22
SH11CR-M/01
Other caratteristics C15
A C
D
B
Flushing valve Arranged for flushing valve
A
B
DC5A1G1_0000000 - 01/22
SH11CR-M/01
C16 Other caratteristics
B 30°
TW TZ
2-Channel differential-hall effect operating principle (1 square 2-Channel differential-hall effect operating principle Sensor
wave -1 digital for direction of rotation) Output signal PNP with dual-channel output (90°)
Power supply 4.5-16 VDC Power supply 8-32 VDC
Frequency 0 - 20.000 Hz Frequency 0-20.000 Hz
Operating temperature -40°C - +110°C Operating temperature -40°C +125°C
Degree of protection IP67
Sensor connector Deutsch DT04-4P
Electromagnetic compatibility according to EN 60947-5-2
Resistence to schock and vibration in accordance with IEC
68-2-17 IEC 68-2-6
Size
020 045-055 075 108 160
030 063 090 125 180
DC5A1G1_0000000 - 01/22
SH11CR-M/01
C17
S1 S1
S2 S2
For the SH11CR motors it is possible to request the drain plug reversed compared to standard.
If it is necessary the motor with this configuration, to specify in the purchase order the value “RD” (See position 13 of ordering code).
DC5A1G1_0000000 - 01/22
SH11CR-M/01
DC5A1G1_0000000 - 01/22
SH11C - Fixed displacement pumps D1
Index
SH11C 055 56.35 [3.437] 282 [74.45] 430 [6235] 480 [6960]
SH11C 063 63.26 [3.859] 112 [29.5] 430 [6235] 480 [6960]
SH11C 075 77.82 [4.747] 127 [33.5] 430 [6235] 480 [6960]
SH11C 090 86.23 [5.26] 388 [102.5] 430 [6235] 480 [6960]
SH11C 108 108.4 [6.612] 140 [36.96] 430 [6235] 480 [6960]
SH11C 125 124.8 [7.613] 155 [40.92] 430 [6235] 480 [6960]
SH11C 160 163.9 [9.998] 173 [45.67] 430 [6235] 480 [6960]
SH11C 180 178.1 [10.864] 193 [50.95] 430 [6235] 480 [6960]
SH11C pumps are a family of fixed displacement, bent axis piston pumps for operation in open circuit. The proven design
incorporating the lens shape valve plate, the high quality components and manufacturing techniques make the SH11C pumps to
able provide up to 430 bar [6235 psi] continuous and 480 bar [6960 psi] peak performance. Fully laboratory tested and field proven,
these pumps provide maximum efficiency and longlife. Heavy duty bearings permit high radial and axial loads.
Versatile design will be fit the SH11C pumps to any application both industrial and mobile. SH11C pumps are available in both ISO
and SAE version.
DC5A1G1_0000000 - 01/22
SH11C-P/01
D2 General information - Features
Simbology:
N/bar l/min
C
[lbf/psi]
Load Qmax [U.S. gpm]
Maximum flow
N l/min
Fax max Axial pushing load Qd External drain flow
[lbf] [U.S. gpm]
N Nm/bar
Fax max Axial pulling load Tk Torque costant
[lbf] [lbf.ft/psi]
N Nm
Fq Radial load Tmax Maximum torque at pressure continuous
[lbf] [lbf.ft]
N Nm
Fq max Maximum permissible radial load Tpeak Maximum torque at pressure peak
[lbf] [lbf.ft]
kg·m2 cm3/rev
J Moment of inertia Vg Displacement
[lbf·ft2] [in3/rev]
kg kW
m Weight Pmax Maximum power at pnom
[lbs] [hp]
n max rpm Maximum speed ηhm % Mech-hyd. efficiency
bar
pmax [psi]
Maximum continuous pressure ηv % Volumetric efficiency
bar
ppeak [psi]
Maximum pressure peak
Hydraulic fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15 ÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed, for
different types of viscosity please contact Dana. Viscosities less then 10 cSt are not allowed. A viscosity range of 10 ÷ 15 cSt is
allowed for extreme operating conditions and for short periods only.
Temperature ranges:
The operating temperature of the oil must be within -25ºC÷ 115ºC [-13ºF ÷ 239ºF]. For applications with lower temperatures please
contact Dana.
Filtering:
A correct filtering is essential for long and satisfactory life of axial piston units. In order to ensure a correct functioning of the unit,
the max. permissible contamination class is 21/19/16 according to ISO 4406:1999.
Operating pressure:
Maximum permissible case drain pressure is 10 bar [145 psi].
A higher pressure can damage the main shaft seal or reduce its life.
DC5A1G1_0000000 - 01/22
SH11C-P/01
General information - Features D3
p
psi bar 160-180 108-125
220 15
210 075-090
200 14
045-055-063
190 13
180
12
020-030
170
11
010-016
160
150 10
Pressure
140
130 9
120 8
110
100 7
90 6
80
70 5
60 4
50
3
40
30 2
20
1
0 1000 2000 3000 4000 5000 6000 7000 8000 n
Speed rpm
Output shaft:
Table is a guide to determine max. permissible loads. Values are calculated in such a way to assure at least 80% of the bearing
operating life where no external load is applied. The published values are related to loads applied in the middle of shaft and in the
least favourable direction.
Fq
+ Fax
- Fax
* : work in progress
1) : in the following table, values of Fq max for the output shafts
When an external side (radial) load is applied to the drive shaft, the bearing life will vary accordingly to the magnitude, location
and direction of the load. The diagram shows how the bearing operating life varies versus the direction of the load. In the diagram
100% represents the bearing operating life where no external side load is applied to the drive shaft.
DC5A1G1_0000000 - 01/22
SH11C-P/01
D4 General information - Features
120%
Alternating rotation
110%
CCW Pump φ φ CW Pump
Bearing life (%)
100%
B A
90%
80%
70%
-180 -135 -90 -45 0 45 90 135 180
φ (°)
The bearing operating life increases up to 30% when the load is applied with some peculiar directions and the maximum increase
is dependent on the operating pressure and the nominal size of the unit.
When considering the permissible axial force, the force - transfer direction must be taken in account:
• Pushing axial loads increase the bearing life.
• Pulling axial loads reduce the bearing life (if possible pulling axial loads should be avoided).
Seals:
Seals used on SH11C series are of FKM (Fluoroelastomer). In case of use of special fluids, contact Dana.
Installation:
SH11C series motors can be installed in every position or direction. These axial piston units have separate ports and drain
chambers and so must be always drained. For further details see on the General Information Catalogue, the section “General
installation guidelines”.
Flangeable valves:
Flangeable valves are available for motors both in open and closed loop. For more information see the catalogue Axial Valves.
DC5A1G1_0000000 - 01/22
SH11C-P/01
Technical data D5
Size
010* 016* 020 030 045* 055 063 075 090 108 125 160 180
cm3/rev 10.3 16 19.9 31.9 46 56.35 63.26 77.82 86.23 108.4 124.8 163.9 178.1
Displacement Vg [in3/rev] [0.626] [0.976] [1.213] [1.945] [2.807] [3.437] [3.859] [4.747] [5.26] [6.612] [7.613] [9.998] [10.864]
bar 430 430 430 430 430 430 430 430 430 430 430 430 430
Max. pressure pmax [psi] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235] [6235]
bar 480 480 480 480 480 480 480 480 480 480 480 480 480
Max. peak pressure ppeak [psi] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960] [6960]
Max. continuous speed nmax rpm 3150 3150 2500 2500 2245 2000 2000 1800 1800 1600 1550 1450 1450
Max. intermittent speed(1) nmax rpm 6000 6000 4750 4750 4250 3750 3750 3350 3350 3000 3000 2650 2650
l/min 32 50 50 80 103 282 112 127 388 140 155 173 193
Max. flow Qmax [US gpm] [8.5] [13.2] [13.2] [21.1] [27.2] [74.45] [29.5] [33.5] [102.5] [36.96] [40.92] [45.67] [50.95]
Nm 71 110 136 218 315 386 433 533 590 742 855 1122 1219
Max. cont. torque at pmax Tmax [lbf.ft] [52.36] [81.13] [100.23] [160.66] [232.33] [284.48] [319.12] [392.82] [435.13] [546.85] [630.13] [826.91] [898.40]
Nm 79 122 152 244 352 431 484 595 659 829 954 1253 1361
Max peak torque at ppeak Tpeak [lbf.ft] [58.27] [89.98] [112.02] [179.82] [260.36] [317.65] [356.71] [438.51] [486.05] [610.97] [703.10] [923.46] [1003.06]
kg·m2 0.0005 0.0005 0.001 0.001 0.004 0.004 0.004 0.007 0.007 0.012 0.012 0.022 0.022
Moment of inertia (3) J [lbf.ft2] [0.0118] [0.0118] [0.0235] [0.0235] [0.094] [0.094] [0.094] [0.1645] [0.1645] [0.2820] [0.2820] [0.5170] [0.5170]
kg 6 6 10 10 18 19 19 23.7 23.7 35 35 48 48
Weight (3) m [lbs] [13.22] [13.22] [22.04] [22.04] [39.68] [41.876] [41.876] [52.23] [52.23] [77.14] [77.14] [105.79] [105.79]
* : work in progress
(Theorical values, without considering ηhm and ηv approximate values). Peak operations must not exceed 1% of every minute. A
simultaneous maximum pressure and maximum speed not recommended.
1) The pump rotation speed my be increased by increasing the suction pressure. To calculate the max. permissible speed related
to the pump suction pressure see the diagram at side.
2) The values are valid for a rotating speed of n1 max cont.
3) Approximate values.
4) Average values at 250 bar [3625 psi] with mineral oil at 45°C [113°F] and 35 cSt of viscosity.
n1 / n1max
2.0
1.9
1.8
1.7
Speed limit
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
p
0.8
0 1 2 3 4 bar
0 10 20 30 40 50 psi
Inlet pressure
DC5A1G1_0000000 - 01/22
SH11C-P/01
D6 Ordering code
The following alphanumeric codes system has been developed to identify all of the configuration options for the SH11C motors.
Use the model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering.
We advise to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Special feature
Flushing valve
Displacement
Mount flange
Valve feature
Direction of
Port cover
Shaft end
Painting
rotation
Version
Series
Pump
Valve
Seal
SH11C P 030 ME OC CMB FP2 DX V XXXX 000 XX RD 01
1
Series
SH11C Fixed displacement, bent axis, axial piston unit
2
Pump
P Pump
3
Displacement
010* 10.3 cm3/rev [0.626 in3/rev]
* : work in progress
4
Version
ME ISO
SE SAE
DC5A1G1_0000000 - 01/22
SH11C-P/01
Ordering code D7
1 2 3 4 5 6 7 8 9 10 11 12 13 14
5
Size
Mount flange
010* - 016* 020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
OA ISO 4 holes Ø 80 mm [Ø3.15 in] ME – – – – –
02 SAE-C 4 holes SE – – – – –
05 SAE-C 4 holes – SE SE SE – –
08 SAE-D 4 holes – – – – SE SE
* : work in progress
1) The ME digit means that the flange in only available for the ISO version.
2) The SE digit means that the flange in only available for the SAE version.
DC5A1G1_0000000 - 01/22
SH11C-P/01
D8 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
6
Size
Shaft end
010* - 016* 020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
Parallel keyed Ø20 mm k6 [0.787 in k6]
CAV ME – – – – –
Key 6x6x30 [0.23x0.23x1.18]
Parallel keyed Ø25 mm k6 [0.984 in k6]
CMB ME – – – – –
Key 8x7x32 [0.31x0.27x1.25]
Parallel keyed Ø25 mm k6 [0.984 in k6]
CBM – ME – – – –
Key 8x7x40 [0.31x0.27x1.57]
Parallel keyed Ø 30 mm k6 [1.181 in k6]
CBN – ME – – – –
Key 8x7x40 [0.31x0.27x1.57]
Parallel keyed Ø 30 mm k6 [1.181 in k6]
CAW – – ME – – –
Key 8x7x50 [0.31x0.27x1.97]
Parallel keyed Ø 35 mm k6 [1.377 in k6]
CBO – – ME–SE – – –
Key 10x8x50 [0.39x031x1.97]
Parallel keyed Ø 40 mm k6 [1.574 in k6]
CBP – – – ME – –
Key 12x8x56 [0.47x0.31x2.204]
Parallel keyed Ø 40 mm k6 [1.574 in k6]
CAK – – – – ME –
Key 12x8x63 [0.47x0.31x2.48]
Parallel keyed Ø 45 mm k6 [1.772 in k6]
CAJ – – – – ME–SE –
Key 14x9x63 [0.55x0.35x2.48]
Parallel keyed Ø 45 mm k6 [1.772 in k6]
CBQ – – – – – ME
Key 14x9x70 [0.55x0.35x2.75]
Parallel keyed Ø 50 mm k6 [1.968 in k6]
CAX – – – – – ME–SE
Key 14x9x70 [0.55x0.35x2.75]
Parallel keyed Ø 35 mm k6 [1.377 in k6]
CAY – – – ME – –
Key 10x8x56 [0.39x0.31x2.204]
SAF Splined W20x1.25x30x14x9g DIN 5480 ME – – – – –
* : work in progress
1) The ME digit means that the flange in only available for the ISO version.
2) The SE digit means that the flange in only available for the SAE version.
DC5A1G1_0000000 - 01/22
SH11C-P/01
Ordering code D9
1 2 3 4 5 6 7 8 9 10 11 12 13 14
7
Size
Port cover
010* - 016* 020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
FP2 Frontal ports ME–SE ME–SE ME–SE ME–SE ME–SE ME–SE
* : work in progress
1) The ME digit means that the flange in only available for the ISO version.
2) The SE digit means that the flange in only available for the SAE version.
8
Direction of rotation (viewed from shaft side)
DX CW
SX CCW
9
Seal
V FKM
10
Valve
XXXX None
11
Valve feature
000 None
DC5A1G1_0000000 - 01/22
SH11C-P/01
D10 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
12
Flushing valve
XX None
13
Size
Special feature
010* - 016* 020 - 030 045* - 055 - 063 075 - 090 108 - 125 160 - 180
XX None • • • • • •
RD Drain plugs reversed – • • • • •
* : work in progress
• : Available
14
Painting
XX None
DC5A1G1_0000000 - 01/22
SH11C-P/01
Dimensions ISO 4 Bolts flange (OA) SH11C 010-016 ME D11
120.2 [4.73]
29 [1.14] 95 [3.741]
R
11.1 [0.44]
6 [0.24]
Ø 100 [3.94]
S1
Ø 79.5 [3.13]
96 [3.78]
Ø 80 [3.15]
58 [2.28]
40
60 [2.36]
7 Port cover
FP2
Visto Detail
da C/Detail
C C
178.3 [7.019]
135 [5.302] 15 [0.591]
59 [2.328]
103.8 [4.086]
M33x2
18 [0.71] Depth
Prof. / Depth
C
M22x1.5
14 [0.55] Prof.
Depth/ Depth
6 Shaft end
28 [1.10]
M6
M10x1.0
M10x1.0 [0.39]
Ø25 [0.98]
16
6 [0.236]
Ø20 [0.78]
[0.63] 22 [0.87] 16
[0.63]
22 [0.87]
21[0.83] 30 [1.18]
20 [0.79] 20 [0.79]
20 [0.79] 20 [0.79]
40 [1.89] 54 [2.13]
60 [2.36] 60 [2.36]
DC5A1G1_0000000 - 01/22
SH11C-P/01
D12 Dimensions ISO 4 Bolts flange (OB) SH11C 020-030 ME
134 [5.28]
23.2 [0.91] 27 [1.06]
10.7 [0,42]
8 [0.31] Ø 118 [4.64]
R 12
5[
4.9
2]
S1
S1, S2: Drain ports (1 plugged) - 3/8 G (BSPP)
Ø 100 [3.94]
Ø 95 [3.74]
118 [4.65]
A, B: Service line ports
°
40
.43]
1 [0
18 [0.71] Ø1
67 [2.64]
S2
64 [2.52]
7 Port cover
FP2
VistoDetail C
da C/Detail C
191.1 [7.52]
87.4 [3.44]
]
94
.5
[1
9
.4
22.23 [0.875]
40
C 47.63 [1.875]
18
.2 M8
4
[0
173.1 [6.82] .7
18
]
6 Shaft end
Profilo /Spline
Spline Profilo /Spline
Spline
Key/ Key
Linguetta Key/ Key
Linguetta W25x1.25x30x18x9g DIN 5480 W30x2x30x16x9g DIN 5480
8x7x40 UNI 6604 8x7x40 UNI 6604
Ø29.6 [1.165]
Ø24.8 [0.976]
28 [1.10]
Ø 25 [0.984]
33 [1.29]
Ø30 [1.181]
M10
M8
M10
M8
22 [0.86] 19 [0.74]
19 [0.74] 22 [0.86]
28 [1.10]
30 [1.18] 30 [1.18]
28 [1.10]
25.1 [0.98]
25 [0.98] 25 [0.98]
25 [0.98]
58.1 [2.28]
75 [2.95] 60 [2.36]
75 [2.95]
DC5A1G1_0000000 - 01/22
SH11C-P/01
Dimensions ISO 4 Bolts flange (OC) SH11C 045-055-063 ME D13
78 [3.07]
70 [2.76]
10 [0.393] 10 [0.393] 150 [5.91]
° 45°
R 45
Ø125 0-0.063 [4.921 00.00248 ]
S1
S1, S2: Drain ports (1 plugged) - 1/2 G (BSPP)
40°
75.5 [2.97]
79.5 [3.13]
59.5 [2.34]
7 Port cover
FP2
215.3 [8.48]
168.8 [6.65] VistoDetail
da C/Detail
C C
88.4 [3.48]
151 [5.94]
147 [5.79]
1” SAE 6000
3/4” SAE 6000 M10
18 [0.708] Depth
137.8 [5.43]
A
26.19 [1.031]
23
Ø19 [0.748]
.8
[0
.9 C
37 52.37 [2.062]
]
0]
.0
[2
M10 Prof.18
.8
6 Shaft end
32 [1.26]
Ø29.6 [1.17]
28 1.102
Ø34.5 [1.36]
38 1.496
33 [1.30]
Ø300.015
M10
M12
M10
+0,000
+0,001
67 [2.64] 72 [2.83]
DC5A1G1_0000000 - 01/22
SH11C-P/01
D14 Dimensions ISO 4 Bolts flange (OD) SH11C 075-090 ME
85.5 [3.37]
29 [1.14] 155.7 [6.13]
164.8 [6.49]
10 [0.393] 14 [0.55]
R ° 45°
45
12.1 [0.48]
Ø140 0-0.063 [5.512 00.00248 ]
83.3 [3.27]
Ø
62.8 [2.47]
7 Port cover
FP2
232.6 [9.16] Detail
Visto da C C
C/Detail
183.2 [7.21]
165 [6.50]
85.7 [3.37]
30.18 [1.188]
18 [0.71]
1”1/4 SAE 3000
1”SAE 6000
95.1 [3.75]
148.3 [5.84]
5]
.2
[2
5
.1
27
57
.7
6
[1 C 58.72 [2.312]
.0 M10 Prof.17
93
] M10 DepthDepth
17 [0.669] [0.669]
M12 Prof.17
M12
17 DepthDepth
[0.669] [0.669]
6 Shaft end
AS 10x8x56 AS 12x8x56
0.0007
0.0007
M16
M12
Ø39.5 [1.55]
Ø34.5 [1.36]
0.018
Ø35 0.018
38 [1.49]
43 [1.69]
M12
M16
Ø40
DC5A1G1_0000000 - 01/22
SH11C-P/01
Dimensions ISO 4 Bolts flange (OE) SH11C 108-125 ME D15
14.7[0.578]
Ø2
Ø160 0-0.063[6.299 0-0.0024]
00
[7.8
74]
S1 S1, S2: Drain ports (1 plugged) - 1/2 G (BSPP)
Ø 158 [6.22]
191 [7.52]
A, B: Service line ports
40°
Ø1
7.5 R: Air bleed (plugged) - 1/8 G (BSPP)
90 [3.543]
[0.6
9]
10 [0.39] S2
36.5 [1.44]
59.5 [2.34]
7 Port cover
FP2
265.9 [10.47]
212.8 [8.38]
Visto da C/Detail
Detail C C
111.9 [4.40]
197 [7.76]
35.71 [1.045]
20 [0.79]
1”1/2 SAE 3000
1”1/4 SAE 6000
164.5 [6.48]
]
25
.6
[2
31
8
.6
.7
66
5 C
[1
.2 M12 Prof.20
5]
M12
20 Depth [0.787]
[0.787] Depth
M14 Prof.25 69.85 [2.75]
M14
25 Depth [0.984]
[0.984] Depth
6 Shaft end
ProfiloSpline
/ Spline Profilo Spline
/ Spline
Key/ Key
Linguetta Linguetta
Key/ Key W40x2x30x18x9g DIN 5480 W45x2x30x21x9g DIN 5480
12x8x63 UNI 6604 14x9x63 UNI 6604
0.002 [Ø1.574 0.00007 ]
0.0007
48.5 [1.91]
Ø39.6 [1.56]
Ø44.5 [1.75]
43 [1.69]
M12
M16
M12
M16
Ø 40 0.018
Ø 45 0.018
23 [0.91] 36 [1.42]
37.4 [1.47] 42 [1.65]
28 [1.10] 36 [1.42]
40 [1.57] 40 [1.57]
40 [1.57] 40 [1.57]
85 [3.35] 90 [3.54]
120 [4.73] 120 [4.73]
DC5A1G1_0000000 - 01/22
SH11C-P/01
D16 Dimensions ISO 4 Bolts flange (OF) SH11C 160-180 ME
13.9[0.547]
Ø180 0-0.025[7.087 0-0.0098]
210 [8.27]
A, B: Service line ports
R: Air bleed (plugged) - 1/8 G (BSPP)
40°
113 [4.449]
9]
8.81
24 [
Ø2
9]
0.6
37.2 [1.46] 7. 5[
S2 Ø1
10 [0.39]
71.8 [2.827]
7 Port cover
FP2
293.7 [11.56]
236.5 [9.31]
Visto Detail C
da C/Detail C
111.9 [4.40]
205 [8.07]
15 [0.59]
35.71 [1.045]
]
25
.6
[2
31
8
.6
.7
66
5 C
[1 M12 Prof.20
.2
5]
20M12 DepthDepth
[0.787] [0.787]
69.85 [2.75]
M14 Prof.28
28
M14[1.102] Depth
Depth [1.102]
6 Shaft end
53.5 [2.11]
Ø44.5 [1.75]
Ø49.8 [1.96]
0.0007
0.0007
M16
M16
M16
M16
Ø 45 0.018
Ø 50 0.018
36 [1.42] 36 [1.42]
42 [1.65] 47.8 [1.88]
36 [1.42] 36 [1.42]
40 [1.57] 40 [1.57]
40 [1.57] 40 [1.57]
90 [3.54] 95 [3.74]
130 [5.12] 130 [5.12]
DC5A1G1_0000000 - 01/22
SH11C-P/01
Dimensions SAE C 4 Bolts flange (OA) SH11C 010-016 SE D17
11.1[0.44]
S1
Ø 101.6 [4]
40°
59 [2.32]
9.7 [0.38] S2
12 [0.47]
73.3 [2.89]
7 Port cover
FP2
Visto da C/Detail
Detail C C
178.3 [7.019]
135 [5.302] 15 [0.59]
59 [2.328]
103.8 [4.086]
1”5/16
20
Prof.[0.787] Depth
20 / Depth [0.787]
C
1”1/16
20
Prof.[0.787] Depth
20 / Depth [0.787]
6 Shaft end
Splined
S05 shaft
Spline
Profilo / Spline
D.P. 16/32 Z13 ANSI B92.1 26 [1.02]
Ø5/16-18 UNC
19
[0.75]
34 [1.34]
41.9 [1.65]
DC5A1G1_0000000 - 01/22
SH11C-P/01
D18 Dimensions SAE C 4 Bolts flange (O5) SH11C 020-030 SE
146 [5.75]
154.3 [6.08]
45° 45°
12.7 [0.50] 20 [0.79] Ø
16
14.5 [0.57]
2[
6.3
8]
]
-0.002
S1
0
146 [5.75]
S1, S2: Drain ports (1 plugged) - 3/4”-16 UNF 2B
Ø127 0-0.05 [5.00
40°
S2
Ø1
67 [2.64]
81 [3.19]
4.3
[0.5
6]
7 Port cover
FP2
208.2 [8.20]
Visto da C/Detail
Detail C C
169.1 [6.66]
69.7 [2.75]
]
94
.5
[1
9
.4
40
22.23 [0.875]
C 47.63 [1.875]
18
.2
4
5/16”-18 UNC 2B [0
.7
18
]
6 Shaft end
Spline
Profilo / Spline
Profilo /Spline
Spline
Key D.P. 16/32 Z13 ANSI B92.1
D.P. 12/24 Z14
6.35x6.2x28 ANSI B92.1 a 1976
[0.25x0.24x1.10]
5/16”-18 UNC-2B
7/16”-14 UNC-2B
Ø31.2 [1.228]
Ø21.8 [0.858]
24.9 [0.98]
5/16”-18 UNC 2B
Ø22.22 [0.874]
28 [1.10]
22 [0.86]
32 [1.26]
26 [1.02] 31 [1.22]
56 [2.20]
31 [1.22]
41.1 [1.62]
DC5A1G1_0000000 - 01/22
SH11C-P/01
Dimensions SAE C 4 Bolts flange (O5) SH11C 045-055-063 SE D19
163.2 [6.43]
12.7 [0.50] 34.1 [1.34] 146 [5.75]
73 [2.87]
17.5 [0.69] 45°
45°
15.5 [0.61]
R
-0.05 [5.00 -0.002 ]
S1 .56]
.3 [0
0
8]
[ 6.3
S2 79.5 [3.13]
62
75 [2.95]
1
Ø
83.6 [3.29]
7 Port cover
FP2
239.4 [9.42]
192.9 [7.60] Detail
Visto da C
C/Detail C
88.4 [3.48]
151 [5.94]
147 [5.79]
1” SAE 3000
3/4” SAE 6000 3/8” - 16 UNC Prof.18
3/8” - 16 UNC
18 [0.708] Depth [0.708]
Depth
137.8 [5.43]
23 A
26.19 [1.031]
Ø19 [0.748]
.8
[0
.9 C
37 52.37 [2.062]
]
0]
.0
[2
3/8”[0.708]
18 - 16 UNC Depth [0.708]
Depth
50
6 Shaft end
Key
Linguetta / Key Spline
Key Profilo / Spline Spline
7.93x7.3x40 [0.31x0.287x1.57]
10x8x50 UNI 6604 D.P. 12/24 Z14 ANSI
B92.1 a 1976
D.P.16/32 Z21 ANSI
32 [1.26]
B92.1a 1976
38 [1.5]
3/8”-16 UNC-2B
3/8”-16 UNC 2B
35 [1.38]
Ø31.2 [1.23]
1,378 ++0.0.00071
00008
-0.0019 ]
3/8" 16 UNC 2B
31.5 1.24
0
Ø 31.75 0-0.05 [1.25
28 [1.1]
39.6 1.56
∅ 35 ++0.018
0.002
DC5A1G1_0000000 - 01/22
SH11C-P/01
D20 Dimensions SAE C 4 Bolts flange (O5) SH11C 075-090 SE
12.7 [0.50] 180.9 [7.122]
146 [5.75]
73 [2.87]
39 [1.535]
20 [0.79] 45° 45°
13.3 [0.523]
R
-0.05 [5.00 -0.002 ]
S1
0
.56]
.3 [0
Ø 14
73 [2.87]
S2 87.7 [3.452]
93 [3.661]
7 Port cover
FP2
256.9 [10.11]
207.4 [8.165] Detail
Visto da C C
C/Detail
95.1 [3.744]
165 [6.50]
85.7 [3.37]
30.18 [1.188]
18 [0.71]
1”1/4” SAE 3000
1” SAE 6000
148.5 [5.85]
5]
.2
[2
27
.7
5
6
.1
[1
57
.0
93
] C 7/16” - 14 UNC 2B Prof.22 58.72 [2.312]
7/16”
22 - 14 UNC
[0.866] 2B Depth [0.866]
Depth
7/16” - 14 UNC 2B Prof.22
7/16”
22 - 14 UNC
[0.866] 2B Depth [0.866]
Depth
6 Shaft end
3/8" 16 UNC 2B
32 [1.26]
49.15 [1.94]
-0,0020
1/2” 20 UNF
0
39.6 [1.56]
1,75
32 [1.26] 8 [0.315]
-0,05
39.6 [1.56]
Ø 44,45
55.78 [2.2]
55.6 [2.18]
DC5A1G1_0000000 - 01/22
SH11C-P/01
Dimensions SAE D 4 Bolts flange (O8) SH11C 108-125 SE D21
215.8 [8.496]
200 [7.87]
12.7 [0.50] 49.6 [1.952]
45°
45°
24.9 [0.98]
15.3 [0.602]
Ø2
R 28.
Ø152.4 0-0.05 [6.00 0-0.0019 ]
6 [9
.00
]
S1 S1, S2: Drain ports (1 plugged) - 1” 1/16-12 UN 2B
200 [7.87]
40°
93 [3.661]
Ø2 R: Air bleed (plugged) - 7/16”-20 UNF
0.6
[0.8
1]
S2
91.6 [3.29]
7 Port cover
FP2
297.9 [11.73]
244.9 [9.64]
Visto Detail C
da C/Detail C
111.8 [4.40]
197 [7.76]
35.71 [1.045]
20 [0.79]
1”1/2 SAE 3000
1” 1/4 SAE 6000
164.4 [6.47]
]
25
.6
[2
8
31
.6
.7
66
5
[1 C
.2 1/2” - 13 UNC 2B Prof.24
5]
1/2” - 13 UNCDepth
24 [0.945] 2B Depth [0.945]
1/2” - 13 UNC 2B Prof.19 69.85 [2.75]
1/2”[0.748]
19 - 13 UNC 2B Depth [0.748]
Depth
6 Shaft end
Key
Linguetta / Key Spline Spline/ Spline
Profilo
Profilo / Spline
11.11x9.2x60 [0.43x0.36x2.36] D.P. 8/16 Z13 ANSI D.P. 16/32 Z23 ANSI
B92.1 a 1976 B92.1 a 1976
36 [1.42]
49.1 [1.94]
1/2” 20 UNF
Ø43.9 [1.73]
1/2” 20 UNF
Ø38 [1.50]
[1.748 0+0.0019]
1/2” 20 UNF
69.7 [2.75]
Ø 44.4
74.9 [2.95]
DC5A1G1_0000000 - 01/22
SH11C-P/01
D22 Dimensions SAE D 4 Bolts flange (O8) SH11C 160-180 SE
200 [7.87]
232 [9.134]
48.9 [1.925]
45°
45°
12.7 [0.50]
13.2 [0.519]
R
Ø152.4 0-0.05 [6.00 0-0.0019 ]
200 [7.87]
40°
113 [4.449]
8.6 [9
Ø 22
]
[0.83
Ø 21
25 [0.98] S2
103.9 [4.09]
7 Port cover
FP2
325.8 [12.83]
268.6 [10.58] Detail
Visto da C C
C/Detail
129.8 [5.11]
205 [8.07]
15 [0.59]
35.71 [1.045]
]
25
.6
[2
C
31
8
.6
.7
66
5
[1 1/2” - 13 UNC 2B Prof.24
.2
5]
1/2”[0.945]
24 - 13 UNC 2B Depth [0.945]
Depth
1/2” - 13 UNC 2B Prof.19 69.85 [2.75]
19
1/2”[0.748] Depth
- 13 UNC 2B Depth [0.748]
6 Shaft end
Parallel Splined
C18 Albero
keyed shaft
cilindrico S15 shaft
Linguetta
Key/ Key
Linguetta
11.11x9.2x60 [0.43x0.36x2.36]
Spline
Profilo / Spline
Profilo
36 [1.42] D.P. 8/16 Z13 ANSI
B92.1 a 1976
49.1 [1.94]
1/2” 20 UNF
Ø43.9 [Ø1.73]
1/2” 20 UNF
Ø44.4 0+0.05 [1.748 +0.0019]
0
DC5A1G1_0000000 - 01/22
SH11C-P/01
Other caratteristics D23
S1 S1
S2 S2
For the SH11C is possible to request the drain plug reversed compared to standard.
If it is necessary in this configuration, to specify in the purchase order the value “RD” (see position 13 of ordering code).
DC5A1G1_0000000 - 01/22
SH11C-P/01
DC5A1G1_0000000 - 01/22
H1C - Fixed displacement pump / motors E1
Indice
Displacement Max. flow motor Max. flow pump Max. pressure cont.
Type
cm3/rev [in3/rev] l/min [U.S. gpm] l/min [U.S. gpm] bar [psi]
H1C 006 6.067 [0.37] 36.4 [9.61] 30.3 [7.99] 350 [5100]
H1C 040 40.1 [2.45] 175 [46.1] 132 [34.8] 350 [5100]
H1C 226 225.1 [13.73] 540 [142.5] 360 [95] 350 [5100]
H1C series units are a family of fixed displacement pumps and motors, bent axis piston design for operation in both open and closed
circuit. The proven design incorporating the lens shape valve plate, the high quality components and manufacturing techniques
make the H1C series units to able provide up to 350 bar [5100 psi] continuous and 450 bar [6500 psi] peak performance. Fully
laboratory tested and field proven, these units provide maximum efficiency and longlife. Heavy duty bearings permit high radial and
axial loads. Versatile design includes a variety of port plate, shaft end and valves package that will adapt the H1C series units to any
application both industrial and mobile. H1C series units are available in both ISO and SAE version.
DC5A1G1_0000000 - 01/22
H1C-MP/01
E2 General information - Features
Simbology:
N/bar l/min
C
[lbf/psi]
Load Qmax [U.S. gpm]
Maximum flow
N l/min
Fax max Axial pushing load Qd External drain flow
[lbf] [U.S. gpm]
N Nm/bar
Fax max Axial pulling load Tk Torque costant
[lbf] [lbf.ft/psi]
N Nm
Fq Radial load Tmax Maximum torque at pressure continuous
[lbf] [lbf.ft]
N Nm
Fq max Maximum permissible radial load Tpeak Maximum torque at pressure peak
[lbf] [lbf.ft]
kg·m2 cm3/rev
J Moment of inertia Vg Displacement
[lbf·ft2] [in3/rev]
kg kW
m Weight Pmax Maximum power at pnom
[lbs] [hp]
n max rpm Maximum speed ηhm % Mech-hyd. efficiency
bar
pmax [psi]
Maximum continuous pressure ηv % Volumetric efficiency
bar
ppeak [psi]
Maximum pressure peak
Hydraulic fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15 ÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed.
Viscosities less then 10 cSt are not allowed. A viscosity range of 10 ÷ 15 cSt is allowed for extreme operating conditions and for short
periods only. For further information see on the General Information Catalogue, the section “Fluids and filtering”.
Temperature ranges:
The operating temperature of the oil must be within -25ºC÷ 90ºC [-13ºF ÷ 194ºF]. The running of the axial piston unit with oil
temperature higher than 90ºC [194°F] or lower than -25ºC [-13°F] is not allowed. For further information see at Fluids and filtering
section.
Filtering:
A correct filtering is essential for long and satisfactory life of axial piston units. In order to ensure a correct functioning of the unit, the
max. permissible contamination class is 21/19/16 according to ISO 4406:1999. For further details see on the General Information
Catalogue, the section “Fluids and filtering”.
Inlet pressure:
(Pumps in open circuit) Minimum absolute pressure at suction port is 0.8 bar [11.6 psi]. In no circumstances can inlet pressure be
lower.
P1 P2 P3
DC5A1G1_0000000 - 01/22
H1C-MP/01
General information - Features E3
Operating pressure:
The maximum permissible pressure on pressure ports is 350 bar [5100 psi] continuous and 450 bar [6500 psi] peak. If two motors
are connected in series, working pressure has to be limited to following values: P1 400 bar max. [5800 psi] and P2 200 bar max.
[2900 psi].
Seals:
Seals used on standard H1C series axial piston pumps/motors are of NBR (Acrylonitrile-Butadiene Elastomer). For special uses
(high temperatures or corrosive fluids) it is possible to order the unit with FKM seals (Fluoroelastomer). In case of use of special
fluids, contact Dana.
Output shaft:
Main shaft has bearings that can bear both radial and axial loads. As for loads permissible values, see on the General Information
Catalogue, the section “Service life of bearings for axial piston units”.
Installation:
H1C series pumps and motors can be installed in every position or direction. These axial piston units have separate ports and drain
chambers and so must be always drained. As for pumps, installation of the unit with shaft in vertical position and above the tank
involves some limitations. For further details see on the General Information Catalogue, the section “General installation guidelines”.
Flangeable valves:
Flangeable valves are available for motors both in open and closed loop. For further details see at Valves Catalogue.
Note: for pump operation, the direction of rotation is determined by the port plate mounting position. Usually, in order to change
direction of rotation of a pump, port plate has to be removed, turned of 180° and reassembled.
DC5A1G1_0000000 - 01/22
H1C-MP/01
E4 Technical Data
Dimensione
006 012 040 226
cm3/rev 6.067 10.9 40.1 225.1
Displacement Vg [in3/rev] [0.37] [0.66] [2.45] [13.73]
* Max. speed pump (1) nmax rpm 5000 4300 3300 1600
kW 17.7 27 77 210
Max. power at pmax pump Pmax [hp] [23.7] [36] [103] [281]
kg 5.5 5.5 22 86
Weight (3) m [lbs] [12.1] [12.1] [48.5] [189.5]
(Theorical values, without considering ηhm e ηv approximate values). Peak operations must not excede 1% of every minute. A
simultaneus maximum pressure and maximum speed not recomended.
* Pump values refer to open circuit operation.
1.7
1.4
Speed limits
n / n1max
1.2
1.1
0.9
0.8
0 1 2 3 4 5 bar
0 10 20 30 40 50 60 70 psi
DC5A1G1_0000000 - 01/22
H1C-MP/01
Ordering code E5
The following alphanumeric codes system has been developed to identify all of the configuration options for the H1C series. Use
the model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering.
We advise to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Special feature
Flushing valve
Valves feature
Displacement
Mount flange
Motor/pump
Direction of
Port cover
Shaft end
Painting
rotation
Version
Series
Valve
Seal
H1C M/P 006 ME/SE OA CAV LM1 RV N/V XXXX 000 XX XX XX
1
Series
H1C Fixed displacement, bent axis, axial piston unit
2
Motor / Pump
M Motor
P Pump
3
Displacement
006 6 cm3/giro [0.366 in3/rev]
4
Displacement
Version
006 012 040 226
ME ISO • • • •
SE SAE – – • •
•: Available
–: Not Available
5
Dispacement
Mount flange
006 012 040 226
OA ISO 4 Bolts Ø 80 mm [Ø 3.12 in] ME ME – –
05 SAE-C 4 Bolts – – SE –
10 SAE-E 4 Bolts – – – SE
1) The ME digit means that the flange is only available for the ISO version
2) The SE digit means that the flange is only available for the SAE version
DC5A1G1_0000000 - 01/22
H1C-MP/01
E6 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
6
Displacement
Shaft end
006 012 040 226
CAV Parallel keyed Ø 20 mm k6 [0.79 in k6] ME ME – –
7
Displacement
Port Cover
006 012 040 226
LM1 Lateral ports (Motor) ME ME – –
- : Not Available
(*) The port cover threads are ISO also in SAE option.
1) The ME digit means that the port cover is only available for the ISO version.
2) The SE digit means that the port cover is only available for the SAE version.
3)The ME-SE digit means that the port cover is available for the ISO and SAE version.
4) Special on request.
8
Direction of rotation (viewed from shaft side)
RV Reversibile (Motor)
DX CW (Pump)
SX CCW (Pump)
DC5A1G1_0000000 - 01/22
H1C-MP/01
Ordering code E7
1 2 3 4 5 6 7 8 9 10 11 12 13 14
9
Seal
N NBR
V FKM
10
Displacement
Valve
006 012 040 226
XXXX None • • • •
VCDM VCD/M Pilot assisted overcentre valve – – VM2 –
•: Available
–: Not Available
The valves are available with ISO port cover only, please contact Technical department for SAE version The VSD1 is not available with flushing valve.
1) The VM2 digit means that the valve is only available with VM2 port cover.
2) The LM2 digit means that the valve is only available with LM2 port cover.
11
Valves
Valves feature
XXXX VCDM VCD1 VCD2 VCR3 VSD1
•: Available
–: Not Available
Please contact Technical department for valve which requie specific setting.
For the feature see catalogue valves.
DC5A1G1_0000000 - 01/22
H1C-MP/01
E8 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
12
Displacement
Lushing valve
006 012 040 226
XX Not Required • • • •
06 Flushing Valve VSC/F - 6 l/min – – LM2-VM2 LM2
• : Available
– : Not Available
It is not possible to combine the flushing valves with valve in pos.10
For the feature see catalogue valves.
13
Displacement
Special feature
006 012 040 226
XX None • • •1)
•
01 Special shaft seal 5 bar [72.5 psi] – – •2)
•
03 SAE Version with ISO port cover – – •3)
•4)
• : Available
– : Not Available
1) Not available with SAE version and VM2 port cover.
2) Only with NBR seals.
3) Available with FM1 - VM2 - LP2 port cover.
4) Available with LM2 port cover.
14
Displacement
Verniciatura
006 012 040 226
XX None • • • •
01 Black Painted RAL 9005 • • • •
02 Blue Painted RAL 5015 • • • •
• : Available
– : Not Available
DC5A1G1_0000000 - 01/22
H1C-MP/01
Dimensions ISO 4 Bolts flange (OA) H1C 006 ME E9
77.5 [3.05]
44 [1.73]
S1 91 [3.58]
45° 45° ]
18.2 [0.72] 30.8 [1.21] 37
3.9
0 0[
ø1
S1, S2: Drain ports (1 plugged) - 3/8 G (BSPP)
ø80 h8 [3.149]
91 [3.58]
11°
54] S: Suction port
[0.3
ø9
77.5 [3.05] S2
51 [2.01]
7 Port cover
FP1
Vista da C/Detail
Detail C C
172 [6.77]
90 [3.54]
G1”
59.3 [2.33]
A S
18.1 [0.71]
22 [0.86]
G 3/4”
C
148 [5.82]
167.7 [6.60] 20 [0.79]
LM1
Vista da C/Detail
Detail C C
172 [6.77]
90 [3.54]
59.3 [2.33]
A B
C
18.1 [0.71]
G 3/4”
G 3/4”
148 [5.82]
6 Shaft end
CAV Splined
shaft SAF Splined
shaft
Prof. 23 Depth
Prof. 23Depth
Spline
Linguetta/Key Spline
Profilo/Splined
ø20 K6 [0.787]
23[0.91]
M6M6
M6
ø19.7 [0.775]
22.5 [0.88]
DC5A1G1_0000000 - 01/22
H1C-MP/01
E10 Dimensions ISO 4 Bolts flange (OA) H1C 012 ME
58 [2.28]
91 [3.58]
40.5 [1.59]
38 [1.50] S1
7]
45° 45° .93
11 [0.43] 0 [3
ø10
91 [3.58]
20°
59 [2.32]
28 [1.10] 58 [2.28]
7 Port cover
FP1 For pump operation (open circuit) LM1 For motor operation
90 [3.54]
32 [1.26]
39 [1.53]
90 [3.54]
32 [1.26]
G1”
67 [2.64]
A S A B
67 [2.64]
C
G 3/4”
G 3/4”
G 3/4”
C
124 [4.88]
20 [0.79]
143 [5.63] 124 [4.88]
FM1 For motor operation Upon request FLM For motor operation Upon request
Detail
Vista da C C
C/Detail
Detail
Vista da C C
C/Detail 150 [5.90]
39 [1.53]
32 [1.26]
90 [3.54] 90 [3.54]
G 3/4” G 3/4”
39 [1.53]
M22x1.5 M22x1.5
A B
67 [2.64]
A B
67 [2.64]
C
42 [1.65] C 34 [1.34]
M22x1.5
143 [5.63]
124 [4.88]
150 [5.90] 143 [5.63]
6 Shaft end
Splined Splined
CAV shaft SAF shaft
Spline Profilo/Splined
23 [0.91] Depth
M6 Depth [0.91]
Prof.Depth.
23
M6 Prof. 23
ø19.7 [0.77]
A 6x6x30 UNI6604
22.5 [0.88]
[0.91]
23M6
40 [1.57] 40 [1.57]
34 [1.34] 40 [1.57]
DC5A1G1_0000000 - 01/22
H1C-MP/01
Dimensions ISO 4 Bolts flange (OC) H1C 040 ME E11
60 [2.36]
20 [0.79]
45° 45° [ 6.2
S1 60
ø1
S1, S2: Drain ports - (1 plugged) - 1/2 G (BSPP)
ø125 h8 [4.921]
150 [5.90]
18°
S: Suction port
R: Air bleed (plugged) - 1/8 G (BSPP)
R R15
10 [0.393] 73 [2.87] [0.59] ø13 [0.511]
S2
95 [3.74]
7 Port cover
FM1 - FP1 For pump operation (open circuit) LM2 For motor operation
43 [1.69]
0]
[2.0
50.8
A B
107 [4.21]
ø18 [0.71]
ø18 [0.71]
A B
107 [4.21]
C C
75 [2.95]
20M10
[0.79] Depth 140 [5.51]
Prof. 20
226 [8.89] 135 [5.31] 204 [8.03] M10 Depth [0.79]
Vista da C/Detail
Detail C C
224 [8.82]
60 [2.36]
ø19 [0.75]
150 [5.90]
A
108 [4.25]
75 [2.95]
3/4” SAE6000
6 Shaft end
Key Spline
Profilo/Splined
Linguetta/Key
M10 Depth [0.87]
W30x2x14x9g DIN5480
M10 Depth [0.87]
22
ø29.6 [1.165]
22
Prof.
Prof.
33 [1.29]
[0.87]
[0.87]
22M10
22M10
DC5A1G1_0000000 - 01/22
H1C-MP/01
E12 Dimensions ISO 4 Bolts flange (OG) H1C 226 ME
142 [5.59]
31 [1.22] 236 [9.29]
92 [3.62]
38 [1.49] 2]
84
10 [0.393] S1 45° 45°
0 [9.
ø25
ø200 h8 [7.874]
236 [9.29]
A, B: Service line ports
25° S: Suction port
R: Air bleed (plugged) - 1/8 G (BSPP)
R25
45 [1.77] R [0.98]
7 Port cover
FP2 For pump operation (open circuit) LM2 For motor operation
95 [3.74]
1” 1/4 SAE6000 3” 1/2 SAE3000 4]
6]
6]
.62
.62
120 [4.72]
7 [2
191 [7.52]
7 [2
S
189.5 [7.46]
A B
66.
A
66.
ø32 [1.26]
ø32 [1.26]
C
ø32 [1.26]
69.8 [2.748]
ø89 [3.50]
C
120.6 [4.748]
28M14
[1.10] Depth
Prof. 28 220 [8.66]
310 [12.20] 28M14
[1.10] Depth
M14 Depth [1.10] 310 [12.20] Prof. 28
220 [8.66]
M14 Depth [1.10]
364 [14.33] 25M16
[0.99] Depth
Prof. 25
M16 Depth [0.98]
Vista da C/Detail
Detail C C
120.6 [4.748]
398 [15.67] 3” 1/2 SAE3000 1” 1/4 SAE6000
31. 1” 1/4 SAE6000
6 [1
.24
95 [3.74]
4]
6]
A B
.62
69.8 [2.748]
ø32 [1.26]
ø32 [1.26]
7 [2
189.5 [7.46]
66.
220 [8.66]
C
25M16
[0.99] Depth
Prof. 25
28M14
[1.10] Depth
Prof. 28 M16 Depth [1.01]
310 [12.20] M14 Depth [1.10]
6 Shaft end
Parallel Splined
CAX keyed shaft SAR shaft
M16 Depth [1.42]
KeyLinguetta/Key Profilo/Splined
Spline
Depth
W50x2x24x9g DIN5480
ø49.6 [1.953]
Prof.
53.5 [2.11]
Prof.
[1.42]
[1.42]
36M16
36M16
DC5A1G1_0000000 - 01/22
H1C-MP/01
Dimensions SAE C 4 Bolts flange (05) H1C 040 SE E13
98 [3.86]
150 [5.90]
15.7 [0.62]
70 [2.75]
7]
12.7 [0.50] 45° 45° 37
S1
2 [6.
ø 16
ø127 -0.05 [5.00 -0.0019]
150 [5.90]
18° S: Suction port
+0
R16
[0.63]
S2
98 [3.86] 77 [3.03] ø14.3 [0.563]
7 Port cover
294.5 [11.60]
257/16”-14
[0.99] Depth.
UNC 2B Prof. 25
Vista Detail C
da C/Detail C
42.9 7/16”-14 UNC 2B Depth [0.99]
[1.6
88]
2” SAE3000 1” SAE6000
57.1 [2.248]
48 [1.89]
63]
[3.0
77.8
107 [4.21]
S
C B
ø25 [0.98]
27.8 [1.094] ø51 [2.01]
251/2”-13
[0.99] Depth.
UNC 2B Prof. 25 160 [6.29]
243 [9.57] 1/2”-13 UNC 2B Depth [0.99]
270 [10.63]
Vista Detail C
da C/Detail C
27.8
[1.0
94] 1” SAE6000 1” SAE6000
43 [1.69]
48]
[2.2
57.1
107 [4.21]
C A B
ø25 [0.98]
ø25 [0.98]
207/16”-14
[0.79] Depth.
UNC 2B Prof. 20 140 [5.51]
229 [9.01] 7/16”-14 UNC 2B Depth [0.79]
6 Shaft end
Splined Splined
C17
CAK Parallel
shaftshaft
keyed S12 shaft
3/8”-16 UNC 2B 32 [1.26]
Prof. 32 Depth. 3/8”-16 UNC 2B 32 [1.26]
Prof. 32 Depth.
3/8”-16 UNC 2B Depth [1.26]
[1.25 -0.0019]
A 0.31x0.29x1.57
Linguetta Key
A 7.93x7.3x40 Spline
Profilo/Splined
A 0.31x0.29x1.57 Key D.P. 12/24 z 14
35.05 [1.38]
ø31.2 [1.23]
ø31.75 -0.05
+0
8 [0.314] 8 [0.314]
DC5A1G1_0000000 - 01/22
H1C-MP/01
E14 Dimensions SAE E 4 Bolts flange (10) H1C 226 SE
130 [5.12]
25 [0.98]
265 [10.43]
S1, S2: Drain ports (1 plugged) - 1” 3/16-12 UN 2B
A, B: Service line ports
105 [4.13]
12.5 [0.492] ]
2.5 S: Suction port
45° 45° [1
15.8 [0.62] .5
R S1 17 R: Air bleed (plugged) - 7/16”-20 UNF
ø3
ø165.1 -0.05 [6.5 -0.0019]
+0
265 [10.43]
25°
+0
R19
S2 [0.75]
130 [5.12] 105 [4.13] ø20.6 [0.81]
7 Port cover
441 [17.36]
36 Vista Detail
da C/Detail
C C 335/8”-11
[1.30] Depth
UNC 2B Prof. 33
.5 5/8”-11 UNC 2B Depth [1.30]
[1.
43
7]
95 [3.74]
35 [1.38]
69.8 [2.748]
ø89 [3.50]
5]
1” 1/2 SAE6000
.12
4 [3
191 [7.52]
79.
C S
A
120 [4.72]
ø38 [1.49]
3”1/2 SAE3000
353 [13.90]
355/8”-11
[1.38] Depth
UNC 2B Prof. 35
407.5 [16.04] 5/8”-11 UNC 2B Depth [1.38] 120.6 [4.748]
5]
.12
4 [3
191 [7.52]
79.
A S
C
ø38 [1.49]
ø38 [1.49]
220 [8.66]
353 [13.90] 355/8”-11
[1.38] Depth
UNC 2B Prof. 35
5/8”-11 UNC 2B Depth [1.38]
6 Shaft end
Parallel Splined
C18 keyed shaft S15 shaft
1/2”-20
36 [1.42] UNF Prof. 36
Depth 361/2”-20
[1.42] Depth
UNF Prof. 36
[1.75 -0.0019]
A 0.44x0.36x2.36
Linguetta Key
A 11.11x9.2x60 Spline
Profilo/Splined
A 0.44x0.36x2.36 Key
ø43.7 [1.720]
D.P. 8/16 z 13
49.15 [1.93]
ø44.45 -0.05
+0
DC5A1G1_0000000 - 01/22
H1C-MP/01
DC5A1G1_0000000 - 01/22
DC5A1G1_0000000 - 01/22
H1CR - Plug-in fixed displacement motors for gearbox F1
Index
H1CR series are a family of fixed displacement motors, bent axis piston design for operation in both open and closed circuit. H1CR
series motors are mainly intended for installation in mechanical gearboxes such as track drive and winches gear boxes.
The proven design incorporating the lens shape valve plate, the high quality components and manufacturing tecniques make the
H1CR series motors able to provide up to 350 bar [5100 psi] continuos and 450 bar [6500 psi] peak performance.
Fully laboratory tested and field proven, these motors provide maximum efficiency and long life. Heavy duty bearings permit high
radial and axial loads.
Flangeable valves, both for open and closed circuit, enable H1CR series motors to meet the requirements of the most different
types of applications.
DC5A1G1_0000000 - 01/22
H1CR-M/01
F2 General information - Features
Simbology:
N/bar l/min
C [lbf/psi]
Load qmax [U.S. gpm]
Maximum flow
N l/min
Fax max [lbf]
Axial pushing load qd [U.S. gpm]
External drain flow
N Nm/bar
Fax max [lbf]
Axial pulling load Tk [lbf.ft/psi]
Torque costant
N Nm
Fq [lbf]
Radial load Tnom [lbf.ft]
Maximum torque at pressure cont.
N Nm
Fq max [lbf]
Maximum permissible radial load Tmax [lbf.ft]
Maximum torque at pressure peak
kg·m2 cm3/rev
J [lbf·ft2]
Moment of inertia Vg [in3/rev]
Displacement
kg kW
m [lbs]
Weight Pmax [hp]
Maximum power at pnom
Hydraulic fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed.
Viscosities less then 10 cSt are not allowed. A viscosity range of 10÷15 cSt is allowed for extreme operating conditions and for short
periods only. For further information see at Fluids and filtering section.
Temperature ranges:
The operating temperature of the oil must be within -25ºC÷90ºC [-13ºF÷194ºF]. The running of the axial piston unit with oil temperature
higher than 90ºC [194°F] or lower than -25ºC [-13°F] is not allowed. For further information see at Fluids and filtering section.
Filtering:
A correct filtration helps to extend the service life of axial piston units. In order to ensure a correct functioning of the unit, the max.
permissible contamination class is 21/19/16 according to ISO 4406:1999. For further details see at Fluids and filtering section.
Operating pressure:
The maximum permissible pressure on pressure ports is 350 bar [5100 psi] continuos and 450 bar [6500 psi] peak. It two motors
are connected in series, working pressure has to be limited to following values: P1 400 bar max. [5800 psi] and P2 200 bar max.
[2900 psi].
P1 P2 P3
DC5A1G1_0000000 - 01/22
H1CR-M/01
General information - Features F3
Seals:
Seals used on standard H1CR series axial piston motors are of NBR (Acrylonitrile-Butadiene Elastomer). For special uses (high
temperatures or corrosive fluids) it is possible to order the unit with FKM seals (Fluoroelastomer). In case of use of use special fluids,
contact Dana.
Installation:
H1CR motors can be installed in various position and directions; however, installation in vertical position with shaft towards upper
is not allowed. These axial piston units have separated ports and drain chambers and so must be always drained. For further detail
see at General installation guidelines.
Installation:
H1CR motors can be installed in various position and directions; however, installation in vertical position with shaft towards upper
is not allowed. These axial piston units have separated ports and drain chambers and so must be always drained. For further detail
see at General installation guidelines.
Flangeable valves:
Flangeable valves are available for motors both in open and closed loop. VSC06F, VSC09F, VSC15F AND VSC21F flushing valves
are for closed loop, VCD/M overcentre valve is for open loop. For further details see at Valves section.
DC5A1G1_0000000 - 01/22
H1CR-M/01
F4 Technical data
cm3/rev 44.3
Displacement Vg [in3/rev] [2.67]
bar 350
Max. Press. cont. pnom [psi] [5100]
bar 450
Max. Press. peak pmax [psi] [6500]
l/min 186
Max. flow qmax [U.S.gpm] [49]
kW 108
Max. power at pnom Pmax [hp] [145]
Nm/bar 0.70
Torque costant Tk [lbf.ft/psi] [0.036]
Nm 247
Max. torque cont. at pnom Tnom [lbf.ft] [182]
Nm 317
Max torque peak at pmax Tmax [lbf.ft] [233.6]
kg·m2 0.004
Moment of inertia (1) J [lbf.ft2] [0.094]
kg 20
Weight (1) m [lbs] [44.1]
l/min 0.7
External drain flow (2) qd [U.S.gpm] [0.18]
* Out of production
(Theorical values, without considering ηhm and ηv; approximate values). Peak operations must not excede 1% of every minute.
A simultaneus maximum pressure and maximum speed not recomended.
Pump values refer to open circuit operation.
Notes:
(1)Approximate values.
(2)Average values at 250 bar [3600 psi] with mineral oil at 45°C [113°F] and 35 cSt.
DC5A1G1_0000000 - 01/22
H1CR-M/01
Ordering code F5
The following alphanumeric codes system has been developed to identify all of the configuration options for the H1CR series.
Use the model code below to specify the desired features. All alphanumeric digits system of the code must be present when
ordering. We advise to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Special feature
Flushing valve
Valves feature
Displacement
Mount flange
Direction of
Port cover
Shaft end
Painting
rotation
Version
Series
Motor
Valve
Seal
H1CR M 045 GE OL SAI LM2 RV V VCDM 000 06 RD 01
1
Series
H1CR Plug-in fixed displacement motors for gearbox
2
Motor
M Motor
3
Displacement
030 35 cm3/rev [2.135 in3/rev]
4
Version
ME ISO
SE SAE
5
Flange
OL 2 bolts Ø 160 mm h6 [Ø 6.3 in]
6
Shaft end
SAI Splined W30x2x14x9g DIN 5480
DC5A1G1_0000000 - 01/22
H1CR-M/01
F6 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
7
Port cover
FM1 Frontal ports
8
Direction of rotation (viewed from shaft side)
RV Reversible
9
Seal
N NBR
V FKM
10
Port cover
Valve
FM1 LM2 VM2
XXXX None • • •
VCDM VCD/M Pilot assisted overcentre valve – – •
VCR3 VCR3 Control Rotation Valve – – •
– : Not available
• : Available
11
Valve
Valvel feature
XXXX VCDM VCR3
000 None • – –
Please contact Technical department for valve which require specific setting. For the technical specifications see catalogue valves.
DC5A1G1_0000000 - 01/22
H1CR-M/01
Ordering code F7
1 2 3 4 5 6 7 8 9 10 11 12 13 14
12
Port cover
Flushing valve
FM1 LM2 VM2
XX None • • •
06 VSC/F Flushing valve - 6 l/min [1.58 U.S. gpm] – • •
09 VSC/F Flushing valve - 10.5 l/min [2.77 U.S. gpm] – • •
15 VSC/F Flushing valve - 15 l/min [3.96 U.S. gpm] – • •
21 VSC/F Flushing valve - 20 l/min [5.28 U.S. gpm] – • •
– : Not available
• : Available
It is not possible to combine the flushing valves with valve in pos.10. For the technical specifications see catalogue valves.
13
Special feature
XX None
14
Painting
XX None
DC5A1G1_0000000 - 01/22
H1CR-M/01
F8 Dimensions 2 Bolts flange (OL) H1CR 045
90 [3.54] 80 [3.14]
15 [0.59] 15 [0.59]
45 [1.77]
S1
18 [0.70]
Ø160 h6 [6.299]
164 [6.45]
Ø121 [4.76]
88 [3.46]
OR 2-163 196 [7.716]
S2
30 [1.18]
Ø235 [9.251]
7 Port cover
LM2 FM1
183.3 [7.21] Detail C 180.6 [7.11]
Visto da C/Detail C
Visto Detail C
da C/Detail C
23.8
47.8 [1.88]
Ø18 [0.70]
[0.9
37]
3/4” SAE 6000
G 1”1/4
00]
A B
[2.0
110.6 [4.35]
A
109.7 [4.31]
B
Ø18 [0.70]
50.8
G 1”1/4
3/4” SAE 6000
55.5 [2.18]
C
140 [5.511] 75 [2.952]
C
M10 Depth
Prof.2020 135 [5.31]
141.9 [5.58] 163.5 [6.43]
[0.79][0.79]
M10 Depth
VM2
Visto Detail C
da C/Detail C
160.3 [6.31]
M10 Depth
Prof.1818
23.8 [0.937] [0.71][0.71]
M10 Depth
3/4” SAE 6000
75 [2.952]
150 [5.90]
50.8 [2.000]
112.8 [4.44]
5°
0.7
9[
130.4 [5.13]
Ø1
6 Shaft end
22 [0.86]
Ø29.6 [1.165]
M10
Profilo / Spline
Spline
W30x2x14x9g DIN5480
35 [1.37]
129.7 [5.10]
DC5A1G1_0000000 - 01/22
H1CR-M/01
Special version F9
S1 S1
S2 S2
For the H1CR motors it is possible to request the drain plug reversed compared to standard.
If it is necessary the motor with this configuration, to specify in the purchase order the value “RD” (See position 13 of ordering code).
DC5A1G1_0000000 - 01/22
H1CR-M/01
DC5A1G1_0000000 - 01/22
H1V - Variable displacement axial piston pumps for open circuit G1
Index
H1V series are a family of variable displacement pumps, bent axis piston design for operation in open circuit. The proven design
incorporating the lens shape valve plate, the high quality components and manufacturing tecniques make able the H1V series
pumps to provide up to 350 bar [5100 psi] continuous and 450 bar [6500 psi] peak performance. Fully laboratory tested and field
proven, these pumps assure maximum efficiency and long life, even at very bad filtering conditions. Heavy duty bearings permit
high radial and axial loads.
Versatile design includes a variety of control and shaft ends that will adapt the H1V series pumps to any application both industrial
and mobile. H1V series pumps are available in both ISO and SAE version.
DC5A1G1_0000000 - 01/22
H1V-P/01
G2 General information - Features
Simbology:
N/bar bar
C Load pmax Maximum pressure peak
[lbf/psi] [psi]
N l/min
Fax max Axial pushing load qmax Maximum flow
[lbf] [U.S. gpm]
N l/min
Fax max Axial pulling load qd External drain flow
[lbf] [U.S. gpm]
N Nm/bar
Fq Radial load Tk Torque costant
[lbf] [lbf.ft/psi]
N Nm
Fq max Maximum permissible radial load Tnom Maximum torque at pressure cont.
[lbf] [lbf.ft]
kg·m2 Nm
J Moment of inertia Tmax Maximum torque at pressure peak
[lbf·ft2] [lbf.ft]
kg cm3/rev
m Weight Vg Displacement
[lbs] [in3/rev]
kW
n0 max rpm Maximum speed Pmax Maximum power at pnom
[hp]
bar
pnom Maximum cont. pressure ηhm % Mech-hyd. efficiency
[psi]
ηv % Volumetric efficiency
Hydraulic fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed.
Viscosities less then 10 cSt are not allowed. A viscosity range of 10¸15 cSt is allowed for extreme operating conditions and for short
periods only. For further information see at Fluids and filtering section.
Temperature ranges:
The operating temperature of the oil must be within -25ºC÷90ºC [-13ºF÷194ºF]. The running of the axial piston unit with oil temperature
higher than 90ºC [194°F] or lower than -25ºC [-13°F] is not allowed. For further information see at Fluids and filtering section.
Filtering:
A correct filtering is essential for long and satisfactory life of axial piston units. In order to ensure a correct functioning of the unit,
the maximum permissible contamination class is 21/19/16 according to ISO 4406:1999. For further details see at Fluids and filtering
section.
Inlet pressure:
(Pumps in open loop) Minimum absolute pressure at suction port is 0.8 bar [11.6 psi]. Case inlet pressure can never be lower.
Operating pressure:
The maximum permissible continuous pressure on pressure ports is 350 bar [5100 psi]. The peak pressure is 450 bar [6500 psi].
DC5A1G1_0000000 - 01/22
H1V-P/01
General information - Features G3
Seals:
Seals used on standard H1V series axial piston pumps are of NBR (Acrylonitrile-Butadiene Elastomer). For special uses (high
temperatures or special fluids) it is possible to order the unit with FKM seals (Viton®). In case of use of special fluids, contact Dana.
Output shaft:
Shaft has bearings that can bear both radial and axial loads. As for loads permissible values, see relevant section at Service life of
bearings for axial piston units.
Port plates:
The H1V pump port plate has outlet ports, both lateral (L2 cover) and frontal (F2 cover). Unused port is plugged with a blind flange.
The kind of port to be used must be specified when ordering. The suction port is always frontal.
Installation:
H1V series pumps can be installed in every position or direction. These axial piston units do not have have separate inlet and drain
chambers and so must be never drained. Installation of the unit with shaft in vertical position and above the tank involves some
limitations. For further details see at General installation guidelines.
DC5A1G1_0000000 - 01/22
H1V-P/01
G4 Technical data
Displacement
55 75 108 160 226
cm3/rev 54.8 75.3 107.5 160.8 225.1
Max. displacement Vgmax
[in3/rev] [3.34] [4.60] [6.56] [9.81] [13.73]
cm3/rev 0 0 0 0 0
Min. displacement Vgmin
[in3/rev] [0] [0] [0] [0] [0]
bar 350
Max. Press. cont. pnom
[psi] [5100]
bar 450
Max. Press. peak pmax
[psi] [6500]
Max. speed at Vgmax nmax1 (2) rpm 2600 2300 2000 1800 1500
Max. speed at Vg <Vgmax nmax2 (2) 3300 2900 2600 2300 1900
Speed limit nlim (3) rpm 3700 3200 2800 2500 2100
(Theorical values, without considering ηhm e ηv; approximate values). Peak operations must not excede 1% of every minute.
A simultaneus maximum pressure and maximum speed not recomended.
Notes:
1. The minimum and maximum displacements are infinitely adjustable. In the order code please indicate the needed Vgmax
and Vgmin.
2. The values shown are valid for an absolute pressure of 1 bar [14.5 psi] at the suction inlet port an when operated on mineral oil.
By decreasing the the displacement the speed may be increased to the max permissible speed, see diagram.
3. By increasing the inlet pressure (pabs > 1 bar [14.5 psi]) the speed my be increased to the max. permissible speed (nlim), see
diagram.
4. Approximate values.
DC5A1G1_0000000 - 01/22
H1V-P/01
Technical data G5
1.3
2 [29]
1.8 [26.1]
1.4 [20.3]
1.1
1.2 [17.4]
1 1 [14.5]
0.8 [11.6]
0.9
0.8
0.6 0.7 0.8 0.9 1 Vg / Vgmax
Displacement
DC5A1G1_0000000 - 01/22
H1V-P/01
G6 Ordering code
The following alphanumeric codes system has been developed to identify all of the configuration options for the H1V pumps.
Use the model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering.
We advise to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 A 6B 6C 6D 6E 7 8 9
Displac. setting
Direct. of rotat.
Displacement
Displacement
min / max
Prressure
Port plate
Shaft end
1500 rpm
Solenoid
Power at
Version
Control
voltage
Series
Seals
H1V 075 S L2 D NC 1 030 50 03 17/160 M NBR
1
Series
H1V Variable displacement axial piston pumps for open circuit
2
Displacement
055 54.8 cm /rev [3.34 in /rev]
3 3
3
Shaft end
C Cylindrical keyed
S Splined
4
Port plate
L2 At side
F2 At rear
5
Direction of rotation (viewed from shaft side)
D CW
S CCW
DC5A1G1_0000000 - 01/22
H1V-P/01
Ordering code G7
1 2 3 4 5 6 A 6B 6C 6D 6E 7 8 9
6
Controls Controls
Pressure controls – – – PC CR – – – –
Hydraulic controls – – – – – PI – – –
6A
Electric controls – – – – – – EM – –
Manual controls – – – – – – – – LC
Displacement
1 (Vgmax - Vgmin) • • • • • • • • •
6B setting
2 (Vgmin - Vgmax) – – – – – • • – •
6C Power at 1500 rpm (kW) See power table
50 ÷ 350 bar
Pressure PC
[725 ÷ 5075 psi]
– • – • • – – – –
6D 18 ÷ 35 bar / 50 ÷ 350 bar
Pressure LS/TP
[261 ÷ 507.5 psi] / [725 ÷ 5075 psi]
– – – – – – – • –
Solenoid
12 Vdc – – – – – – • – –
6E voltage
24 Vdc •
* : with drain
Notes:
1) The NC+PC control is not available with displacement 55 cm3/rev [3.34 in3/rev].
Displacement
Controls NC / NC+PC / NC+PI
55 75 108 160 226
kW 5 ÷ 30 11 ÷ 45 13 ÷ 70 22 ÷ 98 27 ÷ 130
6C Power a 1500 rpm P [hp] [6.7 ÷ 40.2] [14.7 ÷ 60.3] [17.4 ÷ 93.8] [29.4 ÷ 131.2] [36.1 ÷ 174.2]
7
Vgmin / Vgmax
6 / 55 cm3/rev 10 / 75 cm3/rev 13 / 107 cm3/rev 17 / 160 cm3/rev 20 / 225 cm3/rev
[0.37 / 3.36 in3/rev] [0.61 / 4.58 in3/rev] [0.79 / 6.54 in3/rev] [1.04 / 9.77 in3/rev] [1.22 / 13.74 in3/rev] Control NC
0 / 55 cm3/rev 0 / 75 cm3/rev 0 / 107 cm3/rev 0 / 160 cm3/rev 0 / 225 cm3/rev
[0 / 3.36 in3/rev] [0 / 4.58 in3/rev] [0 / 6.54 in3/rev] [0 / 9.77 in3/rev] [0 / 13.74 in3/rev] Other control
8
Version
M ISO
SAE SAE
9
Seals
NBR Nitrile STD
FKM Viton ®
DC5A1G1_0000000 - 01/22
H1V-P/01
G8 Constant power control Control NC
The constant power control makes it possible to control the output flow of the pump in relation to the operating pressure so to keep
the pre-set drive power constant at a constant speed:
p∙Q
N= = cost
600
N = Power (kW)
p = pressure (bar)
Q = flow (l/min)
The operating pressure applies a force on the pilot which is matched by an adjustable spring so that the pump keeps Vg max until
the operating pressure overtakes the pre-set spring force. When the operating pressure rises beyond the pre-set spring force, the
spool valve opens and the positioning piston moves allowing the pump to swivel toward Vg min until a force balance on the control
rod is restored by feed back springs so that the output flow reduces in the same ratio by which the operating pressure has risen.
Therefore at constant drive speed the drive power keeps constant. The displacement setting is (1) (MAX-MIN) with two feed back
springs. Calibration starts from 50 bar [725 psi].
B Y1
Y2 Y3
X1
A T S
H1V 55 H1V 75
psi
psi bar
bar psi
psi bar
bar
5000 350 5000 350
4500 4500
300 300
4000 4000
250 250 45 kW [60.3 hp]
3500 30 kW [40.2 hp] 3500
Pressure
Pressure
DC5A1G1_0000000 - 01/22
H1V-P/01
Constant power control NC G9
4500 4500
300 300
4000 70 kW [93.8 hp] 4000
250 250 98 kW [131.3 hp]
3500 3500
Pressure
Pressure
3000 200 3000 200
50 kW [67 hp]
2500 2500
65 kW [87.1 hp]
150 150
2000 2000
30 kW [40.2 hp] 50 kW [67 hp]
1500 100 1500 100 40 kW [53.6 hp]
1000 1000 30 kW [40.2 hp]
20 kW [26.8 hp]
50 13 kW [17.4 hp] 50
500 500 22 kW [29.4 hp]
0 0
0 20 60 100 140 180 l/min
l/min 0 50 100 150 200 250 l/min
l/min
0 10 20 30 40 U.S. gpm
US GPM 0 10 20 30 40 50 60 U.S. gpm
US GPM
Flow Flow
H1V 226
psi
psi bar
bar
5000 350
4500
300
4000
250 130 kW [174.2 hp]
3500
Pressure
DC5A1G1_0000000 - 01/22
H1V-P/01
G10 Constant power control with pressure compensator NC+PC
The NC+PC control operates as the NC constant power control with the addition of a max pressure cut-off so that, if the operating
pressure exceeds the setting value, the pump automatically detrokes to Vgmin maintaning the pressure.
The pressure limiting device is made by the adjustable sequence valve mounted on the pump. The valve is adjustable up to 350
bar [5000 psi]. The pressure limiting device overrides the constant power control, i.e. below the pre-set operating pressure the
displacement is adjusted according to the pre-set drive power curve and if the operating pressure rises such as to exceed the
pre-set operating pressure, the pressure limiting device overrides the constant power control. It should be required for the pump to
operate long term at zero stroke, more then 200 bar [2900 psi] for more than 5 min., pump flushing is necessary through the S port
and flushing flow must be 7-10% approx. of the nominal pump flow. The VSI T1 port must be connected to the tank directly. Any
relief included in the circuit must be set at least at 30 bar [435 psi] above the pressure limiting device setting. Displacement setting
is (1) (MAX-MIN).
psi bar
H1V NC+PC
A S2 Y3 Y1
psi bar
400
5500
5000 350
4500
300
PC pressure setting
4000
250
Pressure
3500
3000 200
2500
T1 150
2000
1500 100
1000
50
500
S X1 T S1 0
0 10 20 30 40 50 60 70 80 90 100 %
q / qmax
DC5A1G1_0000000 - 01/22
H1V-P/01
Constant power control with hydraulic limiting device NC+PI G11
The NC+PI control operates as the NC constant power control, with the additional option of being able to limit the flow in proportion
of the pilot pressure applied on port X2. The hydraulic limiting device is overridden by the constant power control, i.e. below the pre-
set drive power curve the displacement is adjusted in relation to the pilot pressure and if operating pressure rises such as to exceed
the power curve, the constant power control overrides the hydraulic limiting device and reduces the displacement according to
the power curve. To zero the displacement a piloting pressure of about 10% of working pressure (10 to 35 bar depending on spool
diameter) [145-508 psi] is required at port X2; maximum pressure on X2 port 250 bar [3625 psi].
Displacement setting is (1) (MAX to MIN).
H1V NC+PI
B X2 Y1
psi
psi bar
bar
5000 350
Y2 Y3 4500
300
4000
250
3500
Pressure
3000 200
2500
150
2000
1500 100
1000
50
500
0
X1 0 10 20 30 40 50 60 70 80 90 100 %
q / qmax
A T S X2 Pressure
max min
Control boosting:
When it is necessary to change the displacement of the pump with a working pressure lower than 40 bar [580 psi], the control must
be boosted by means of an auxiliary circuit connected at Y3 port.
5-25 bar
[72.5-362.5 psi]
B X2 Y1
Y2 40 min
Y3 [580 psi]
6 l/min
[1.5 US gpm]
X1
A T S
Note:
The above illustrated circuit has the only aim to show the connection required to construct a boosting circuit.
DC5A1G1_0000000 - 01/22
H1V-P/01
G12 Constant power control PC
The constant pressure control controls the pump displacement in relation to flow requirements in such a way to maintain the pressure
in the hydraulic circuit constant.
The operating pressure applies a force on the pilot which is matched by an adjustable spring. There is no feed back. Should the flow
requirements reduce, the operative pressure rises and exceed the pre-set pressure, consequently the spool opens and the pump
swivels back until the pre-set pressure is restored. The swivel back time to zero stroke is about 0.2 sec.
while the time to restore the output flow is about 0.8 sec. The setting range of the control is 50 bar [725 psi] to 350 bar [5000 psi].
Should it be requested the pump to operate for long time, i.e. more then 200 bar [2900 psi] for more than 5 min, at zero stroke, pump
flushing is necessary through the port S and flushing must be 7% approx. of the nominal pump flow. The relief valve included in the
circuit should be set at least at 30 bar [435 psi] above the constant pressure control setting and the T1 port of the control must be
connected directly to the tank. Displacement settng is (1) (MAX- MIN).
H1V PC
S2 A T1 psi
psi bar
bar
400
5500
5000 350
M
4500
300
Pressure setting
4000
3500 250
Pressure
3000 200
2500
150
2000
1500 100
1000
50
500
0
S X1 T S1
0 10 20 30 40 50 60 70 80 90 100 %
q / qmax
DC5A1G1_0000000 - 01/22
H1V-P/01
Remote constant pressure control CR G13
The constant pressure control of the pump can be remotely piloted by means of the internal piloting sequence valve VSI (see valves
and accessories section). VSI valve is directly assembled on pump, but it also can be ordered separately. Setting adjustment is
50 bar [725 psi] to 350 bar [5075 psi]; the piping length should not exceed 5 mt [16ft]. Port T2 (fixed restrictor) must be directly
connected to the tank and circuit relief valve must be 30 bar [435 psi] higher than the PCR control.
Other features of PCR controls are similar to PC ones.
Displacement setting is 1 (MAX to MIN).
Note:
Please contact our technical department when 2 or more pressure settings are required.
psi bar
H1V CR
psi bar
A S2 Y1 400
5500
Y3 350
Y2 5000
4500
300
Pressure setting
15 bar max
4000
T2 3500 250
Pressure
3000 200
2500
Pm 150
2000
X1 1500 100
1000
S T S1 50
500
0
0 10 20 30 40 50 60 70 80 90 100 %
q / qmax
DC5A1G1_0000000 - 01/22
H1V-P/01
G14 Hydraulic proportional control PI
The hydraulic proportional control allows a stepless adjustment of the pump displacement proportionally to the pilot pressure
applied to port X2. The pilot pressure applies a force on the spool and the pump swivels until a force balance on the arm is
restored by feed back spring. Therefore the pump displacement is adjusted in direct proportion with the pilot pressure. Standard
displacement setting is 2 (Min → Max), however displacement setting 1 (Min → Max) is also available. The required flow can be
obtained by setting the pressure relief valve at X2 port: 8 - 23 bar [115 - 335 psi]. Maximum permissible pilot pressure at port X2 is
50 bar [725 psi] A min. 40 bar [580 psi] approx. operating pressure is required to operate the control. In case of operating pressure
lower than 40 bar [580 psi], a boost pressure must be applied at port Y3 to control the pump.
A S2 X2 Y1
H1V PI (2) H1V PI (1)
Y2 Y3 psi
psi bar
bar psi
psi bar
bar
350 25 350 25
300 20 300 20
250 250
15 15
200 200
Px2
Px2
150 10 150 10
100 100
5 5
50 50
0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 % 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 %
X1 Vg / Vgmax Vg / Vgmax
S T S1
Control boosting:
When it is required to change the displacmeent of the pump with working pressure lower than 40 bar [580 psi], the control must be
boosted by means of an auxiliary circuit connected at port Y3.
5-25 bar
[72.5-362.5 psi]
A S2 X2 Y1
Y2 40 min
Y3 [580 psi]
6 l/min
[1.5 US gpm]
X1
S T S1
Note:
The above illustrated circuit has the only aim to show the connection required to construct a boosting circuit.
DC5A1G1_0000000 - 01/22
H1V-P/01
Electric proportional control EM G15
The electrical proportional control allows stepless and programmable adjustment of the pump displacement proportionally to the
current strength supplied to a proportional solenoid valve, available in 12V DC and 24V DC versions. The proportional solenoid
valve applies a force on the spool proportional to the current strength and the pump swivels until a force balance is restored by
a feed-back spring. To control the proportional solenoid valve a 24V DC (12V DC) supply is required. Current range between 350
(700) and 700 (1400) mA approx. (with standard setting of Max and Min displacement). Max permissible current = 800 (1600) mA.
Usually the swivel range is from Vgmin to Vgmax (displacement setting 2) so that increasing the current strength the pump swivels
towards Vgmax, however displacement setting 1 (swivels range from Vgmax to Vgmin) is also available. A min. 40 bar [580 psi]
approx. operating pressure is required to operate the control. Two electronic devices are available to control the solenoid (they must
be ordered separately): VPD/AD (two channel) - VPC/AP (one channel).
Current
A S2 Y1 12V 12V
1000 1000
800 800
Y2 Y3 600 600
400 400
200 200
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 % 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 %
Vg / Vgmax Vg / Vgmax
Current
500 500
400 400
S X1 T S1 300 300
200 200
100 100
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 % 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 %
Vg / Vgmax Vg / Vgmax
Control boosting:
When it is required to change the displacement of the pump with working pressure lower than 40 bar [580 psi], the control must
be boosted by means of an auxiliary circuit connected at port Y3.
40 min
A S2 Y1 [580 psi]
Y2
Y3
6 l/min
[1.5 US gpm]
X1
S T S1
Note:
The above illustrated circuit has the only aim to show the connection required to construct a boosting circuit.
DC5A1G1_0000000 - 01/22
H1V-P/01
G16 Load sensing control with pressure cut-off CLS+TP
The Load Sensing control device is a regulating valve that controls the pump displacement in function of the working pressure so
as to satisfy the demands for the various users. The pump flow is influenced from an external restrictor (the variable restrictor or
proportional compensated flow control valve) placed between the user and the pump.
The Load Sensing control compares the pressure before and after the restrictor and varies the pump displacement so as to maintain
a constant the pressure drop through the restrictor (Δp). In this way, the flow of the pump depends exclusively on the section of
passage of the variable restrictor. The field of calibration of the Δp is contained between 18 bars [261 psi] end 35 bars [507 psi].
The standard calibration is 20 bars [290 psi]. The variable restrictor not supplied with the pump.
The control has a pressure cut-off built-in valve (with drain) with setting from 50 to 350 bar [725 ÷ 5075 psi].
The pressure of calibration of the control however, can not exceed the value of nominal pressure (pnom) of the pump. The pressure
relief valve in the circuit has to be set at a pressure level of at least 20 bar [290 psi] higher than the setting pressure of the TP control.
Not suppliyed
Non fornita
psi
Not supplyed psi bar
bar
400
5500
S2 A T1 X2 5000 350
4500
300
M 4000
3500 250
Pressure
3000
200
2500
150
2000
1500 100
1000
50
500
LS
0
0 10 20 30 40 50 60 70 80 90 100 %
S X1 T S1
q / qmax
DC5A1G1_0000000 - 01/22
H1V-P/01
Manual control LC G17
The pump displacement is adjusted by manually operating the handwheel. The standard swivel range is from Vgmax to Vgmin
(displacement setting 1 as per our ordering code), however displacement setting 2 (swivel range from Vgmin to Vgmax) can be
supplied.
S1
A
S S2
The table shows number of handwheel turns required to swivel the pump from zero displacement to maximum displacement or vice
versa.
Displacement
55 75 108 160 226
Handwhell rounds 28 29 24 36 40
DC5A1G1_0000000 - 01/22
H1V-P/01
G18 Dimensions ISO 4 Bolts flange H1V 55 M
S1, S2: Flushing ports (plugged) - 1/8” G (BSPP)
R: Air bleed (plugged) - 1/8” G (BSPP)
210.5 [8.29]
Ø 125 h8 [4.921]
150 [5.90]
106.5 [4.19]
62 [2.44]
Ø
16 S1
0[
159 [6.26]
6.2
99
]
150 [5.90]
Ø 13 [0.511]
12.5°
186 [7.32]
30.5 [1.20]
42 [1.65]
B R
S2
9 [0.354]
80 [3.15]
45° 45° 18 [0.71]
261 [10.27]
VistoDetail B
da B/Detail B
166 [6.54]
42.9 [1.688]
M10 Prof.22
Depth
22 [0.87]
[0.87] Depth M12 Prof.20
3/4” SAE 6000
Depth
20 [0.79Depth
[0.79] ]
77.8 [3.062]
50.8 [2.00]
Ø19 [0.75]
Ø51 [2.01]
23.8 [0.937]
48 [1.89] 45 [1.77]
73 [2.87]
3 Shaft end
Splined Parallel
S shaft C keyed shaft
Profilo Spline
/ Spline Key
Linguetta A 8x7x50 DIN 6885
W30x2x14x9g DIN 5480 Key A 0.31x0.28x1.97
A 8x7x50 DIN 6885
[0.31x0.28x1.97] DIN 6885
Depth
Ø30 k6 [1.181]
Depth
Ø29.6 [1.165]
M10 Prof. 22
M10 Prof. 22
[0.87]
[0.87]
[0.87]
33 [1.30]
[0.87]
Depth
Depth
22
22
DC5A1G1_0000000 - 01/22
H1V-P/01
Dimensions ISO 4 Bolts flange H1V 75 M G19
231.5 [9.11]
164 [6.46]
Ø 140 h8 [5.511]
101 [3.98]
Ø
67 [2.64]
18
0[
7.0 S1
164.5 [6.48]
86
]
164 [6.46]
Ø 14 [0.551]
12.5°
192.5 [7.58]
33.5 [1.32]
46 [1.81]
B
R
S2
10 [0.393]
80.6 [3.17]
45° 45°
23 [0.91]
93 [3.66]
Vista Detail B
da B/Detail B
287.5 [11.32]
184 [7.24]
50.8 [2.00]
M12 Prof.26
26Depth
[1.02][1.02]
Depth M12 Prof.26
Depth
26 [1.02]
[1.02] Depth
1” SAE 6000
57.2 [2.251]
Ø25 [0.98]
Ø63 [2.48]
88.9 [3.50]
50 [1.97] 41 [1.61] 27.8 [1.094]
80 [3.15]
3 Shaft end
Splined Parallel
S shaft C keyed shaft
Profilo / Spline Linguetta A 10x8x56 DIN 6885
W35x2x16x9g DIN 5480 Key 0.39x0.31x2.20
A 10x8x56 DIN 6885
[0.39x0.31x2.20] DIN 6885
Depth
Depth
Ø34.5 [1.358]
Ø35 k6 [1.377]
M12 Prof. 28
M12 Prof. 28
[1.10]
[1.10]
[1.10]
[1.10]
38 [1.50]
Depth
Depth
28
28
DC5A1G1_0000000 - 01/22
H1V-P/01
G20 Dimensions ISO 4 Bolts flange H1V 108 M
S1, S2: Flushing ports (plugged) - 1/2” G (BSPP)
R: Air bleed (plugged) - 1/8” G (BSPP)
259 [10.20]
190 [7.48]
Ø 160 h8 [6.299]
115 [4.53]
Ø
80 [3.15]
20
0[
7.8 S1
74
168 [6.61]
]
190 [7.48]
Ø 17 [0.67]
12.5°
36.5 [1.44]
204 [8.03]
49 [1.93]
B
R
S2
100.5 [3.96]
10 [0.393]
45° 45°
125 [4.92]
VistaDetail
da B/Detail
B B
317 [12.48]
193.5 [7.62]
50.8 [2.00]
M12 Prof.26
26Depth
[1.02] [1.02]
Depth M12 Prof.26
Depth
26 [1.02]
[1.02] Depth
1” SAE 6000
57.2 [2.251]
Ø25 [0.98]
Ø63 [2.48]
88.9 [3.50]
48 [1.89] 55 [2.16] 27.8 [1.094]
91 [3.58]
3 Shaft end
Splined Parallel
S shaft C keyed shaft
Profilo Spline
/ Spline Key
Linguetta A 12x8x63 DIN 6885
W40x2x18x9g DIN 5480 AKey 0.47x0.31x2.48
12x8x63 DIN 6885
[0.47x0.31x2.48] DIN 6885
Ø40 k6 [1.574]
Depth
Depth
Ø39.5 [1.555]
M12 Prof. 28
M12 Prof. 30
[1.10]
[1.18]
[1.10]
[1.18]
43 [1.69]
Depth
Depth
28
30
DC5A1G1_0000000 - 01/22
H1V-P/01
Dimensions ISO 4 Bolts flange H1V 160 M G21
306 [12.05]
Ø 180 h8 [7.086]
204 [8.03]
100 [3.94]
95 [3.74]
Ø
22
4[ S1
8.8
201 [7.91]
18
]
Ø 18 [0.71]
204 [8.03]
A
12.5°
245 [9.64]
B
58 [2.28]
45 [1.77]
R
S2
105 [4.13]
10 [0.393]
45° 45°
25 [0.98]
1”1/4 SAE 6000
100 [3.94]
Vista Detail B
da B/Detail B
366.5 [14.43]
206 [8.11] M14 Prof.28 31.7 [1.248]
28Depth
[1.10] [1.10]
Depth
M12 Prof.25
1”1/4 SAE 6000 Depth
25 [0.98][0.98]
Depth
66.7 [2.625]
Ø32 [1.26]
89 [3.50]
Ø63 [2.48]
55 [2.16] 46 [1.81] 50.8 [2.00]
100 [3.94]
3 Shaft end
Splined Parallel
S shaft C keyed shaft
ProfiloSpline
/ Spline Key
Linguetta A 14x9x80 DIN 6885
W45x2x21x9g DIN 5480 Key A 0.55x0.35x3.15
A 14x9x80 DIN 6885
[0.55x0.35x3.15] DIN 6885
Depth
Ø45 k6 [1.771]
Depth
Ø44.6 [1.756]
M12 Prof. 36
M12 Prof. 36
[1.42]
[1.42]
[1.42]
48.5 [1.91]
[1.42]
Depth
36Depth
36
DC5A1G1_0000000 - 01/22
H1V-P/01
G22 Dimensions ISO 4 Bolts flange H1V 226 M
S1, S2: Flushing ports (plugged) - 3/4” G (BSPP)
R: Air bleed (plugged) - 1/8” G (BSPP)
333 [13.11]
Ø 224 h8 [8.818]
246 [9.68]
Ø 110 [4.33]
28
0[
105 [4.13]
11
.02 S1
3]
220 [8.66]
Ø 22 [0.87]
252 [9.92]
A
12.5°
275 [10.83]
B
66 [2.60]
50 [1.97]
R
S2
118 [4.64]
10 [0.393]
45° 45°
110 [4.33]
Vista Detail B
da B/Detail B
404.5 [15.92]
245 [9.64]
M14 Prof.28 70 [2.755]
28Depth
[1.10][1.10]
Depth
M16 Prof.28
1”1/4 SAE 6000 28Depth
[1.10][1.10]
Depth
Ø89 [3.50]
Ø32 [1.26]
66.7 [2.625]
120.7 [4.751]
72 [2.83] 52 [2.05] 31.7 [1.248]
105 [4.13]
3 Shaft end
Splined Parallel
S shaft C keyed shaft
Profilo Spline
/ Spline Linguetta A 14x9x80 DIN 6885
Key
[1.42]Depth
Ø49.6 [1.952]
36 [1.42]
M16 Prof. 36
53.5 [2.11]
[1.42]
Depth
[1.42]
Depth
36
DC5A1G1_0000000 - 01/22
H1V-P/01
Dimensions SAE C 4 Bolts flange H1V 55 SAE G23
]-0.0019
319 [12.56] 12.7 [0.5]
+0
234.5 [9.23]
[ 5.00
150 [5.90]
98 [3.86]
-0.05
Ø
70 [2.75]
16 S1
+0
1.9 15.7 [0.62]
[6.
Ø127
159 [6.26]
34
7]
Ø 14.3 [0.562]
150 [5.90]
12.5°
186 [7.32]
30.5 [1.20]
42 [1.65]
B R
S2 8 [0.315]
80 [3.15]
45° 45°
98 [3.86]
Vista Detail
da B/Detail
B B 3/4” SAE 6000 285.5 [11.24]
166 [6.53]
42.9 [1.688]
3/8”-16 UNC 2B Prof.24
Depth
24 [0.94][0.94]
Depth
1/2”-13 UNC 2B Prof.20
3/4” SAE 6000 Depth [0.79]
20 [0.79] Depth
Ø19.1 [0.751]
50.8 [2.00]
77.8 [3.062]
Ø50.8 [2.00]
48 [1.89] 45 [1.77] 23.8 [0.937]
73 [2.87]
3 Shaft end
Splined Parallel
S C
]
+0
ProfiloSpline
/ Spline Key
Linguetta A 7.93x7.3x40
-0.05 [1.25
D.P. 12/24 z 14 A
A 7.93x7.3x40 [0.31x0.29x1.57]
Key 0.31x0.29x1.57
3/8”-16 UNC 2B
3/8”-16 UNC 2B
32 [1.26] Prof.
32 [1.26] Prof.
Ø31.2 [1.228]
45.05 [1.38]
Ø31.75 +0
DC5A1G1_0000000 - 01/22
H1V-P/01
G24 Dimensions SAE D 4 Bolts flange H1V 75 SAE
S1, S2: Flushing ports (plugged) - 1” 1/16-12 UN 2B
R: Air bleed (plugged) - 7/16”-20 UNF
-0.0019 ]
344 [13.54] 12.7 [0.5]
[ 6.00 +0
256 [10.08]
-0.05
22 11.5 [0.452]
8.5
+0
[8.
80 [3.15]
Ø152.4
99 S1 R
6]
164.5 [6.48]
33.5 [1.32]
Ø 20.6 [0.81]
204 [8.03]
12.5°
193 [7.60]
46 [1.81]
B
S2
20 [0.79]
80 [3.15]
45° 45°
105 [4.13]
1” SAE 6000
312 [12.28]
Vista da B / Detail
Detail B B
1” SAE 6000
Ø25.4 [1.00]
Ø63.5 [2.5]
57.1 [2.284]
80 [3.15]
3 Shaft end
Splined Parallel
S shaft C keyed shaft
]
-0.0019
Depth [1.42]
Depth [1.42]
ProfiloSpline
+0
/ Spline
1/2”-20 UNF Prof. 36
1/2”-20 UNF Prof. 36
Depth
A Key 0.44x0.36x2.36
11.11x9.2x60
Ø43.7 [1.720]
[0.44x0.36x2.36]
[1.42]UNF
49.15 [1.93]
UNF
Ø44.45 +0
36 [1.42]
1/2”-20
1/2”-20
36
DC5A1G1_0000000 - 01/22
H1V-P/01
Dimensions SAE D 4 Bolts flange H1V 108 SAE G25
-0.0019 ]
389.5 [15.33] 12.7 [0.5]
[ 6.00 +0
297 [11.69]
204 [8.03]
Ø 130 [5.12]
-0.05
22 12 [0.472]
8.5
90 [3.54]
+0
[8.
S1
Ø152.4
99 R
6]
168 [6.61]
Ø 20.6 [0.81]
204 [8.03]
12.5°
204 [8.03]
36.5 [1.44]
49 [1.93]
B
S2
90 [3.54]
45° 45° 20 [0.79]
130 [5.12]
1” SAE6000
354.5 [13.96]
Vista da B /B
Detail Detail B
1”SAE6000
Ø25.4 [1.00]
57.1 [2.284]
Ø63.5 [2.5]
88.9 [3.5]
48 [1.89] 55 [2.16] 27.8 [1.094]
91 [3.58]
3 Shaft end
Splined Parallel
S shaft C keyed shaft
]
Depth [1.42]
Depth [1.42]
-0.0019
+0
1/2”-20 UNF Prof. 36
Profilo / Spline
Key
-0.05 [1.75
Depth
11.11x9.2x60
43.7 [1.720]
UNF
UNF
[0.44x0.36x2.36]
49.15 [1.93]
[1.42]
Ø44.45 +0
[1.42]
1/2”-20
1/2”-20
36
36
DC5A1G1_0000000 - 01/22
H1V-P/01
G26 Dimensions SAE D 4 Bolts flange H1V 160 SAE
S1, S2: Flushing ports (plugged) - 1” 1/16-12 UN 2B
R: Air bleed (plugged) - 7/16”-20 UNF
-0.0019 ]
447 [17.60] 12.7 [0.5]
[ 6.00 +0
346 [13.62]
204 [8.03]
135 [5.31]
Ø
-0.05
95 [3.74]
22 13 [0.511]
+0
8.5
[8. S1
Ø152.4
R
201 [7.91]
99
6]
Ø 20.6 [0.81]
204 [8.03]
12.5°
245 [9.64]
B
58 [2.28]
45 [1.77]
S2
25 [0.98]
105 [4.13]
45° 45° 135 [5.31]
Ø31 [1.22]
Ø63.5 [2.5]
89 [3.50]
100 [3.94]
3 Shaft end
Splined Parallel
S shaft C keyed shaft
]
-0.0019
Depth [1.42]
Depth [1.42]
+0
Spline/ Spline
Profilo Linguetta A 11.11x9.2x60
1/2”-20 UNF Prof. 36
1/2”-20 UNF Prof. 36
A Key 0.44x0.36x2.36
Key
-0.05 [1.75
D.P. 8/16 z 13
Depth
Depth
11.11x9.2x60
Ø43.7 [1.720]
[0.44x0.36x2.36]
[1.42]UNF
UNF
49.15 [1.93]
Ø44.45 +0
36 [1.42]
1/2”-20
1/2”-20
36
DC5A1G1_0000000 - 01/22
H1V-P/01
Dimensions SAE E 4 Bolts flange H1V 226 SAE G27
-0.0019 ]
493 [19.41] 15.8 [0.62]
[ 6.50 +0
384.5 [15.14]
105 [4.13]
-0.05
7. 12 [0.472]
5
+0
[1
2. S1 R
5]
Ø165.1
220 [8.66]
Ø 20.6 [0.81]
265 [10.43]
12.5°
275 [10.83]
B
66 [2.60]
50 [1.97]
105 [4.13]
S2
25 [0.98]
45° 45°
130 [5.12]
1” 1/4 SAE 6000
Detail B 456 [17.95]
Vista da B / Detail B
Ø31.8 [1.25]
120.7 [4.751]
66.7 [2.625]
Ø88.9 [3.5]
105 [4.13]
3 Shaft end
Splined Parallel
S shaft C keyed shaft
Depth [1.42]
Depth [1.42]
]-0.0019
1/2”-20 UNF Prof. 36
Profilo
Spline/ Spline Linguetta A 11.11x9.2x60
1/2”-20 UNF Prof. 36
+0
Ø43.7 [1.720]
11.11x9.2x60
[1.42]UNF
49.15 [1.93]
[1.42]UNF
[0.44x0.36x2.36]
1/2”-20
Ø44.45 +0
1/2”-20
36
36
DC5A1G1_0000000 - 01/22
H1V-P/01
G28 Control dimensions NC
B
C
Power setting
A B C
Size Version mm mm mm
[in] [in] [in]
295 161 186
M
[11.61] [6.33] [7.32]
55
319 161 186
SAE
[12.55] [6.33] [7.32]
DC5A1G1_0000000 - 01/22
H1V-P/01
Control dimensions NC+PC G29
B
C
Power setting
Y1
A B C D Y1
Size Version mm mm mm mm
[in] [in] [in] [in]
339 164 193 115.5
M
[13.34] [6.45] [7.59] [4.54]
1/4 G (BSPP)
75
364 164 193 115.5
SAE
[14.33] [6.45] [7.59] [4.54]
7/16” - 20 UNF
DC5A1G1_0000000 - 01/22
H1V-P/01
G30 Control dimensions NC+PI
E
X2
G
B
D
F
C
Power setting
A B C D E F G Y X2
Size Version mm mm mm mm mm mm mm
[in] [in] [in] [in] [in] [in] [in]
303 222 186 172.5 301 83 231
M [11.92] [8.74] [7.32] [6.79] [11.85] [3.26] [9.09]
1/4 G (BSPP) 1/8 G (BSPP)
55
349 222 186 167.5 346 83 255
SAE [13.74] [8.74] [7.32] [6.59] [13.62] [3.26] [10.03]
7/16” - 20 UNF 7/16” - 20 UNF
DC5A1G1_0000000 - 01/22
H1V-P/01
Control dimensions PC G31
B
C
Power setting
A B C
Size Version mm mm mm
[in] [in] [in]
317 159.5 186
M
[12.48] [6.27] [7.32]
55
341 159.5 186
SAE
[13.42] [6.27] [7.32]
DC5A1G1_0000000 - 01/22
H1V-P/01
G32 Control dimensions CR
B
C
A B C
Size Version mm mm mm
[in] [in] [in]
295 161 189
M
[11.61] [6.33] [7.44]
55
319 161 189
SAE
[12.55] [6.33] [7.44]
DC5A1G1_0000000 - 01/22
H1V-P/01
Control dimensions Displacement setting 1 PI G33
Min. stroke
Min. stroke adjuster
adjuster
Pilot pressure
X2
E
G
Y2
F
C A
A B C D E F G X2 Y2
Size Version mm mm mm mm mm mm mm
[in] [in] [in] [in] [in] [in] [in]
295 159 186 126.5 274 83 231
M 1/4 G (BSPP) 1/4 G (BSPP)
[11.61] [6.25] [7.32] [4.98] [10.78] [3.26] [9.09]
55
319 159 186 147 302.5 83 255
SAE 7/16” - 20 UNF 7/16” - 20 UNF
[12.55] [6.25] [7.32] [5.78] [11.90] [3.26] [10.04]
DC5A1G1_0000000 - 01/22
H1V-P/01
G34 Control dimensions Displacement setting 2 PI
F
D
C
Y2
Pilot pressure
X2 Max stroke adjuster
A B C D E F G X2 Y2
Size Version mm mm mm mm mm mm mm
[in] [in] [in] [in] [in] [in] [in]
286 119 220 200.5 201.5 142.5 180.5
M 1/4 G (BSPP) 1/4 G (BSPP)
[11.25] [4.68] [8.66] [7.89] [7.93] [5.61] [7.10]
55
310 119 223 221 221 142.5 204.5
SAE 7/16” - 20 UNF 7/16” - 20 UNF
[12.20] [4.68] [8.77] [8.70] [8.70] [5.61] [8.05]
DC5A1G1_0000000 - 01/22
H1V-P/01
Control dimensions Displacement setting 1 EM G35
Y2
D
C
Power setting
A B C D E Y2
Size Version mm mm mm mm mm
[in] [in] [in] [in] [in]
310 207 186 83 231
M 1/4 G (BSPP)
[12.20] [8.14] [7.32] [3.26] [9.09]
55
334 207 186 83 255
SAE 7/16” - 20 UNF
[13.14] [8.14] [7.32] [3.26] [10.4]
DC5A1G1_0000000 - 01/22
H1V-P/01
G36 Control dimensions Displacement setting 2 EM
D
C
Y2
A B C D E Y2
Size Version mm mm mm mm mm
[in] [in] [in] [in] [in]
286 119 281 142.5 180.5
M 1/4 G (BSPP)
[11.25] [4.68] [11.06] [5.61] [7.10]
55
310 119 281 142.5 204.5
SAE 7/16” - 20 UNF
[12.20] [4.68] [11.06] [5.61] [8.05]
DC5A1G1_0000000 - 01/22
H1V-P/01
Control dimensions CLS+TP G37
I
TP control setting
A
B CLS control setting
A B C D E F G H I L LS / LS1 T1
Size Version mm mm mm mm mm mm mm mm mm mm
[in] [in] [in] [in] [in] [in] [in] [in] [in] [in]
299.5 282.6 116.6 260.6 223.5 129.2 137.4 198.5 77 93.5
55 M
[11.79] [11.12] [4.59] [10.26] [8.79] [5.08] [5.41] [7.81] [3.03] [3.68]
1/8 G (BSPP) 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
H1V-P/01
G38 Control dimensions Displacement setting 1 LC
A B C
Size Version mm mm mm
[in] [in] [in]
354 213 185
M
[13.93] [8.38] [7.28]
55
378 213 185
SAE
[14.88] [8.38] [7.28]
DC5A1G1_0000000 - 01/22
H1V-P/01
Control dimensions Displacement setting 2 LC G39
B
C
A B C
Size Version mm mm mm
[in] [in] [in]
284 119.5 278.5
M
[11.18] [4.70] [10.96]
55
308 119.5 278.5
SAE
[12.12] [4.70] [10.96]
DC5A1G1_0000000 - 01/22
H1V-P/01
DC5A1G1_0000000 - 01/22
S5AV - Variable displacement axial piston pumps for open circuit H1
Index
S5AV is a family of pumps for open circuit, axial piston design for mobile and industrial applications. A strong proven rotating roup
allows the pumps to handle high continuous and peak pressure. The pump features patented swash plate assembly resulting in
minimal leaks and high volumetric efficiency. An adjustable maximum/minimum volume stops provides a means of tuning flow to
your system.
Controls options are designed lo provide high accuracy and repeatability of operation.
Versatile design includes 100% through-drive capability for multiple pump options.
DC5A1G1_0000000 - 01/22
S5AV-P/01
H2 General information - Features
Simbology:
N/bar bar
C [lbf/psi]
Load pmax [psi]
Maximum pressure peak
N l/min
Fax max [lbf]
Axial pushing load qmax [U.S. gpm]
Maximum flow
N l/min
Fax max [lbf]
Axial pulling load qd [U.S. gpm]
External drain flow
N Nm/bar
Fq [lbf]
Radial load Tk [lbf.ft/psi]
Torque costant
N Nm
Fq max [lbf]
Maximum permissible radial load Tnom [lbf.ft]
Maximum torque at pressure cont.
kg·m2 Nm
J [lbf·ft2]
Moment of inertia Tmax [lbf.ft]
Maximum torque at pressure peak
kg cm3/rev
m [lbs]
Weight Vg [in3/rev]
Displacement
kW
n0 max rpm Maximum speed Pmax [hp]
Maximum power at pnom
bar
pnom [psi]
Maximum cont. pressure ηhm % Mech-hyd. efficwiency
ηv % Volumetric efficiency
Hydraulic fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15 ÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed.
Viscosities less then 10 cSt are not allowed. A viscosity range of 10 ÷15 cSt is allowed for extreme operating conditions and for short
periods only. For further information see at Fluids and filtration section.
Temperature ranges:
The operating temperature of the oil must be within -25 ºC ÷ 90 ºC (-13 ºF ÷ 194 ºF). The running of the axial piston unit with oil
temperature higher than 90 ºC (194 °F) for lower than -25 ºC (-13 °F) is not allowed. For further information see at Fluids and filtration
section.
Filtration:
A correct filtration is essential for long and satisfactory life of axial piston units. In order to ensure a correct functioning of the unit,
the maximum permissible contamination class is 20/18/15 according to ISO 4406:1999. For further details see at Fluids and filtration
section.
Inlet pressure:
Minimum absolute pressure at suction port 0.8 bar [11.6 psi]. In no case inlet pressure can be lower.
DC5A1G1_0000000 - 01/22
S5AV-P/01
General information - Features H3
Seals:
Seals used on standard S5AV series axial piston pumps are of NBR (Acrylonitrile-Butadiene Elastomer). For special uses (high
temperatures or special fluids) it is possible to order the unit with FKM seals (Viton®).
Warning:
In the unit with FKM (Viton®) version, the seals on the controls are in NBR version.
In case of use of special fluids, contact Dana.
Fq
Displacement
+ Fax
032 045 050 063 075 093
- Fax
Radial load Fq max Ibf 225 225 338 338 540 540
Axial load Fax max Ibf 270 270 338 338 428 428
X/2 X/2
Installation:
S5AV series pumps can be installed in every position or direction. These axial piston units have separate ports and drain chambers
and so must be always drained. Installation of the unit with shaft in vertical position and above the tank involves some limitations.
For further details see at General installation guide lines.
Noise level:
Researches carried out by a university institute supplied us with some data concerning noise level and its correlation with structural
vibrations. These data allow us to state as partial result a max. noise level value of 70 dB, at 1 m distance from the pump, under
following working conditions: max. displacement, rotating speed 1500 rpm, pressure 200 bar [2900 psi] and mineral oil at 45 °C
with viscosity 35 cSt.
DC5A1G1_0000000 - 01/22
S5AV-P/01
H4 Technical data
Displacement
032 045 050 063 075 093
cm3/rev 32.00 43.3 49.65 63.98 75.00 93.76
Displacement (1) Vg max [in3/rev] [1.95] [2.64] [3.05] [3.90] [4.57] [5.72]
cm3/rev 0 0 0 0 0 0
Displacement (1) Vg min [in3/rev] [0] [0] [0] [0] [0] [0]
bar 280 300 320 320 350 320
Press. max. cont. pnom [psi] [4000] [4350] [4600] [4600] [5000] [4600]
bar 350 350 380 380 420 380
Press. max. peak pmax [psi] [5000] [5000] [5500] [5500] [6000] [5500]
Max speed at Vg max(1) n max nom rpm 3150 2700 3000 2500 2250 2100
Minimum Recommended Speed n min rpm 500 500 500 500 500 500
(Theoretical values, without considering hhm and hv;approximate values). Peak operations must not excide 1% of every minute. A
simultaneous maximum pressure and maximum speed are not recommended.
If speed and oil viscosity are different from standard, please contact us.
Notes:
(1)
The values shown are valid for an absolute pressure (pass) of 1 bar [14.5 psi] at the suction inlet port an when operated on
mineral oil in conditions of optimum viscosity.
(2)
Approximate values.
DC5A1G1_0000000 - 01/22
S5AV-P/01
Ordering code H5
The following alphanumeric codes system has been developed to identify all of the configuration options for the S5AV pumps.
Use the model code below to specify the desired features. All alphanumeric digits system of the code must be present when
ordering. We recommend to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Through drive
Displacement
displacement
displacement
Mount flange
Serie feature
of rotation
Maximum
Shaft end
limitation
limitation
Minimum
Direction
Painting
Version
Control
Control
feature
Series
Pump
Seal
S5AV P 032 0÷32 0÷32 ME 02 S10 DX N PCXXX 000 XX XX XX
1
Series
S5AV Variable displacement axial piston pump
2
Pump
P Pump
3
Displacement
032 1.95 in /rev
3
4
Displacement
Maximum displacement limitation
032 045 050 063 075 093
DC5A1G1_0000000 - 01/22
S5AV-P/01
H6 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
5
Displacement
Minimum displacement limitation
032 045 050 063 075 093
• Available
– Not available
6
Version
ME ISO
7
Displacement
Mount flange
032 045 050 063 075 093
02 2 Bolts SAE-B • • • • – –
04 2 Bolts SAE-C – – – – • •
08(*) 4 Bolts SAE-D – – – – • •
* : Not available for second pump Tandem 075 / 093 + 075 / 093.
• Available
– Not available
DC5A1G1_0000000 - 01/22
S5AV-P/01
Ordering code H7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
8
Displacement
Shaft end
032 045 050 063 075 093
• Available
– Not available
9
Direction of rotation (viewed from shaft side)
DX CW
SX CCW
10
Seal
N NBR
V(*) FKM
* : The seals on the Controls are in NBR version.
DC5A1G1_0000000 - 01/22
S5AV-P/01
H8 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
11
Displacement
Control
032 045 050 063 075 093
• Available
– Not available
12
Control
Control feature
PCXXX LSPCX LSPCY NCPCX NLP0X NLP1X
000 None – – – – – –
6.5÷35 S5AV 50 – – – • • •
8÷45 S5AV 63 – – – • • •
Power at 1500 rpm [kW]
9.5÷60 S5AV 75 – – – • • •
12÷60 S5AV 93 – – – • • •
Standard
18÷35 Load Sensing (bar)
20 bar
– • • – • •
Standard
50÷350 Pressure Setting (bar)
305 bar • • • • • •
• Available
– Not available
Please verify the possibility of the values showed with the control diagrams present on the catalogue.
DC5A1G1_0000000 - 01/22
S5AV-P/01
Ordering code H9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
13
Displacement
Through drive
032 045 050 063 075 093
• Available
– Not available
In tandem combinations where 2nd pump is S5AV, use only T0-T1-T2-T4 through drive.
DC5A1G1_0000000 - 01/22
S5AV-P/01
H10 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
14
Serie feature
XX None
15
Painting
XX None
01 Black Paint ed RAL 9005
DC5A1G1_0000000 - 01/22
S5AV-P/01
Operating curves H11
n=1500 rpm
U.S. gpm l/min n=3000 rpm kW hp
100 60 80
25 90 Q 54
70
80 48
20 Wq max 60
70 42
Power
Flow
60 36 50
15
50 Q 30 40
10 40 W qmax 24 30
30 18
20
5 20 12
10 6 10
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 bar
0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 psi
Pressure
n=1500 rpm
U.S. gpm l/min kW hp
n=3000 rpm
40 150 90
140 84 100
36
130 78 90
Q
32 120 72
110 66 80
28
100 60 70
24 W qmax
90 54
60
20 80 48
Power
Flow
70 Q 42 50
16 60 36
W qmax 40
50 30
12 30
40 24
8 30 18 20
20 12
4 10
10 6
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 bar
0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 4500 psi
Pressure
Q
n=1500 rpm W
U.S. gpm l/min
n=2500 rpm kW hp
40 150 90
Q 100
140 84
36
130 78 90
32 120 72
110 x 66 80
28 W qma
100 60 70
24 90 54
60
80 48
Power
20 Q
Flow
70 42 50
16 60 W qmax 36
40
50 30
12 30
40 24
8 30 18 20
4 20 12
10
10 6
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 bar
P
0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 4500 psi
Pressure
The curves are representative of the standard Dana production. Tests made with mineral oil ISO VG 46 at 50°C
DC5A1G1_0000000 - 01/22
S5AV-P/01
H12 Operating curves
Q W
n=1500 rpm
U.S. gpm l/min kW hp
n=2500 rpm
45 170 102 136
160 Q 96 128
40 150 90 120
140 84 112
35 130 78 104
W qmax
120 72 96
30 110 66 88
100 60
Power
Q 80
Flow
25 90 54 72
80 W qmax 48 64
20 70 42 56
60 36 48
15
50 30 40
40 24 32
10
30 18 24
5 20 12 16
10 6 8
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 bar
0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 4500 psi
Pressure
Q
n=1500 rpm W
U.S. gpm l/min n=2500 rpm hp
kW
51 200
190 Q 162
48
180 120
45 170
42 160 135
39 150 100
36 140
33 130
108
Power
x
120 W qma 80
Flow
30 Q
110
27
100
24 60 81
90
21 80 W qmax
18 70
60 40 54
15
12 50
40
9 27
30 20
6 20
3 10
0 0 0 0
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 bar
P
0 350 700 1050 1400 1750 2100 2450 2800 3150 3500 3850 4200 4450 4900 5250 psi
Pressure
Q
n=1500 rpm W
U.S. gpm l/min n=2000 rpm hp
kW
51 200
190 Q 162
48
180 120
45 170
42 160 135
39 150 100
140 Q
36
33 130
Power
108
Flow
30 120 x 80
110 W qma
27
100
24 W qmax 60 81
90
21 80
18 70
60 40 54
15
12 50
40
9 27
30 20
6 20
3 10
0 0 0 0
20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 bar
P
0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 4500 psi
Pressure
The curves are representative of the standard Dana production. Tests made with mineral oil ISO VG 46 at 50°C
DC5A1G1_0000000 - 01/22
S5AV-P/01
Constant pressure control (CTP) Control PCXXX H13
The constant pressure control device allows to maintain a constant pressure in the hydraulic circuit, within the field of regulation of
the pump, by changing the flow to adapt it to the demands of the system.
In absence of pressure, the pump will swivel to the maximum displacement.
The field of calibration of the pressure control device is comprised between 50 [730 psi] and 350 bar [5000 psi]. However, the setting
pressure of the control does not have to exceed the value of the nominal pressure (pnom) of the pump. The pressure relief valve
inserted in the circuit must be set at a pressure of at least 20 bar [290 psi] higher than the setting pressure of the CTP control device.
G P M1
CLS+TP
(bar) 400 5800 (psi)
350 5075
300 4350
250 3625
200 2900
P
150 2175
100 1450
qmin
50 725
qmax 0 0
0 10 20 30 40 50 60 70 80 90 100
V (%)
S T1 R1 T2 R2 M2
The control has a internal drain line to cool the pump during the stand-by operations. The drain flow value depends on pressure setting. The ave-
rage oil flow at different working pressures can be found in the following table.
Oil flow U.S. gpm 0.66 0.92 1.19 1.45 1.58 1.72 1.85
DC5A1G1_0000000 - 01/22
S5AV-P/01
LSPCX
H14 Load sensing control with pressure cut-off (CLS+TP) LSPCY
The Load Sensing control device is a regulating valve that controls the pump displacement in function of the working pressure so
as to satisfy the demands for the various users. The pump flow is influenced from an external restrictor (the variable restrictor or
proportional compensated flow control valve) placed between the user and the pump. The Load Sensing control compares the
pressure before and after the restrictor and varies the pump displacement so as to maintain a constant the pressure drop through
the restrictor (Δp). In this way, the flow of the pump depends exclusively on the section of passage of the variable restrictor. The field
of calibration of the Δp is contained between 18 bars [261 psi] end 35 bars [507 psi]. The standard calibration is 20 bars [290 psi].
The variable restrictor not supplied with the pump.
The control has a pressure cut-off built-in valve. Two are the valves available whit one field of calibration: LSPCX from 50 to 350 bar
[730 ÷ 5000 psi] with drain and LSPCY from 50 to 350 bar [730 ÷ 5000 psi] without drain.
The pressure of calibration of the control however, can not exceed the value of nominal pressure (pnom) of the pump. The pressure
relief valve in the circuit has to be set at a pressure level of at least 20 bar [290 psi] higher than the setting pressure of the TP control.
LS LS
Y1 Y1
CLS+TP
(bar) 400 5800 (psi)
350 5075
300 4350
250
G P M1 G P M1
200 2900
P
150 2175
100 1450
50 725
qmin qmin 0 0
0 10 20 30 40 50 60 70 80 90 100
qmax qmax V (%)
S T1 R1 T2 R2 M2 S T1 R1 T2 R2 M2
DC5A1G1_0000000 - 01/22
S5AV-P/01
Constant power control with constant pressure control (NC+PC) NCPCX H15
The constant power control regulates the pump displacement depending on the working pressure to avoid that the power absorbed
by the pump can never exceed the power supplied by the engine.
The NC+PC includes also the Constant Pressure features that overrides the constant power control.
The minimum pressure of the setting operation of the NC control is between 50 bar [725 psi] and 320 bar [4.640 psi]. The field of
calibration of the pressure control device is comprised between 50 [730 psi] and 350 bar [5000 psi]. The setting pressure of the
control, however can not exceed the nominal pressure (pnom) of the pump.
The pressure relief valve in the circuit has to be set at a pressure level of at least 20 bar [290 psi] higher than the setting pressure
of the TP control.
NC
(bar) 400 5800 (psi)
350 5075
320 bar
300 4350 (4640 psi)
250 3625
Setting range
200 2900
P 150 2175
100 1450
50 bar
50 725
(725 psi)
0 0
0 10 20 30 40 50 60 70 80 90 100
V (%)
PC
G P M1 (bar) 400 5800 (psi)
350 5075
300 4350
200 2900
P
150 2175
100 1450
50 725
0 0
0 10 20 30 40 50 60 70 80 90 100
qmin V (%)
qmax
NC+PC
(bar) 400 5800 (psi)
350 5075
300 4350
250 3625
200 2900
P
150 2175
S T1 R1 T2 R2 M2
100 1450
50 725
0 0
0 10 20 30 40 50 60 70 80 90 100
V (%)
DC5A1G1_0000000 - 01/22
S5AV-P/01
NLP0X
H16 Constant power control with load sensing and pressure cut-off (NC+LS+TP3) NLP1X
The constant power control regulates the pump displacement depending on the working pressure to avoid that the power absorbed
by the pump can never exceed the power supplied by the engine.
The NC+LS+TP3 includes also the Load Sensing and Pressure Cut-Off features.
The minimum pressure of the setting operation of the NC control is between 50 bar [725 psi] and 320 bar [4.640 psi]. The pressure
setting range of the Δp is between 18 bar [261 psi] and 35 bar (507 psi). The standard setting is 20 bar [290 psi].
Inside the control there is a pressure cut-off built-in valve (TP3).
Two are the TP valves available whit one field of calibration:
TP3C from 50 to 350 bar [730 ÷ 5000 psi] with drain and TP3 from 50 to 350 bar [730 ÷ 5000 psi] without drain.
The pressure relief valve in the circuit has to be set at a pressure level of at least 20 bar [290 psi] higher than the setting pressure
of the TP3 control.
NC
LS (bar) 400 5800 (psi)
350 5075
Y1 320 bar
300 4350 (4640 psi)
250 3625
Setting range
200 2900
P
150 2175
100 1450
G P M1 50 bar
50 725
(725 psi)
0 0
0 10 20 30 40 50 60 70 80 90 100
V (%)
TP3
qmin (bar) 400 5800 (psi)
300 4350
200 2900
P
150 2175
S T1 R1 T2 R2 M2
100 1450
50 725
NC+LS+TP3 (Without drain)
0 0
0 10 20 30 40 50 60 70 80 90 100
V (%)
LS 350 5075
300 4350
Y1
250 3625
200 2900
P
150 2175
100 1450
50 725
0 0
0 10 20 30 40 50 60 70 80 90 100
V (%)
DC5A1G1_0000000 - 01/22
S5AV-P/01
Pump and controls dimensions S5AV 032/045 H17
S5AV 032/045 Pump - Mounting flange SAE B 2 Bolts - CTP (PCXXX) Control
DETTAGLIO X
DETAIL X
157.5 [6.20]
M10
ø101.6 [4.00]
17 [0.67] Depht
(SAE-B)
qmin
ø50.8 [2.000]
12
5]
.8
0
[6
[4
]
14
48
.7
4
.7
17
2]
[0
[5
.5
95.1 [3.74]
51
6
A,B
14
]
ø19 [0.75]
23.8 [0.937]
A,B T1
M2
94.5 [3.72]
35 [1.378]
69.9 [2.751]
131.5 [5.18]
45
T2 T2
35 [1.378]
ø39 [1.54]
°
DETTAGLIO Y
52 [2.047]
DETAIL Y
qmax S
R2
92.5 [3.642] 78.6 [3.095]
204.5 [8.05]
65 [2.56]
VISTA W VISTA W
M1
Y VIEW W VIEW W
M1
9 [0.354] 16 [0.63]
R1 S B A S
M2 M2
20 [0.787]
M1
65 [2.56]
143 [5.629]
DC5A1G1_0000000 - 01/22
S5AV-P/01
H18 Pump and controls dimensions S5AV 032/045
S5AV 032/045 Pump - Mounting flange SAE B 2 Bolts - CLS+TP (LSPCX - LSPCY) Control
78.6 [3.09]
115 [4.527]
131.5 [5.18]
TARATURA REGOLATORE TP
TP CONTROL SETTING LS/Y1
13.5 [0.531] LS/Y1
TARATURA REGOLATORE CLS
CLS CONTROL SETTING
8 Shaft options
3/8” 16 UNC-2B
36 [1.42]
1/4"-20UNC-2B [0.22]
∅ 17.8 [0.70]
Key
Linguetta
UNI 6604-A 8x7x36
DC5A1G1_0000000 - 01/22
S5AV-P/01
Pump and controls dimensions S5AV 050/063 H19
S5AV 050/063 Pump - Mounting flange SAE B 2 Bolts - CTP (PCXXX) Control
81.5 [3.21]
TARATURA REGOLATORE CTP 225.5 [8.878] DX-CW
196 [7.716] CTP CONTROL SETTING 194 [7.638] SX-CCW
5]
.8
[6
]
48
qmin T1
45 [1.772]
.7
17
[5
R1 M1
181 [7.13]
164.5 [6.48]
14
M1
67.5 [2.657]
45 [1.772]
T1
45°
ø101.6 [4.00]
W
(SAE-B)
14
122.7 [4.83]
66 [2.598]
[0
.5
5
1]
67.5 [2.657]
A,B
12
M2
2.
R2
2
[4
T2 M2
.8
1
31 [1.22]
]
qmax
125.5 [4.941] DETTAGLIO X
76.5 [3.01] 76.5 [3.01]
ø19 [0.75]
DETAIL X
214.8 [8.457]
23.8 [0.937]
ø50.8 [2.000]
VISTA W VISTA W
VIEW W VIEW W
Y
A,B
M10
M1 M1 17 [0.67] Depht
DETTAGLIO Y
DETAIL Y
ø50 [1.97]
42.9 [1.688]
X M2
M2
S
ROTAZIONE DESTRA ROTAZIONE SINISTRA
M12
CLOCKWISE ROTATION COUNTER-CLOCKWISE ROTATION
20 [0.78] Depht
DC5A1G1_0000000 - 01/22
S5AV-P/01
H20 Pump and controls dimensions S5AV 050/063
S5AV 050/063 Pump - Mounting flange SAE B 2 Bolts - CLS+TP (LSPCX - LSPCY) Control
LS/Y1
81.5 [3.209]
TARATURA REGOLATORE CLS
CLS CONTROL SETTING
LS/Y1
TARATURA REGOLATORE TP
TP CONTROL SETTING
164.5 [6.476]
181 [7.13]
LS: Load Sensing Pressure port - 1/8 G (BSPP) Deep 10 [0.393]
Y1: Remote port - 1/8 G (BSPP) Deep 10 [0.393]
For the ports not showed please to make reference to PCXXX Control
S5AV 050/063 Pump - Mounting flange SAE B 2 Bolts - NC+LS+TP3 (NLP0X-NLP1X) Control
52.3 [2.059] Y1
145.3 [5.72]
LS TARATURA REGOLATORE TP TARATURA REGOLATORE LS
TP CONTROL SETTING LS CONTROL SETTING
183.5 [7.22]
167.5 [6.594]
157.5 [6.2]
TARATURA REGOLATORE NC
NC CONTROL SETTING
M2
67 [2.64]
M2
210.8 [8.299]
224.8 [8.85]
192.8 [7.59]
M1
G
38 [1.496]
DC5A1G1_0000000 - 01/22
S5AV-P/01
Pump and controls dimensions S5AV 050/063 H21
S5AV 050/063 Pump - Mounting flange SAE B 2 Bolts - NC+PC (NCPCX) Control
274.6 [10.81]
159.5 [6.28]
For the ports not showed please to make reference to NLP0X-NLP1X Control
8 Shaft options
Key
Linguetta ANSI B92.1a-1976 35x2x30x16x9g
35 [1.38]
M12
M12
28.5 [1.12]
32 [1.26]
28 [1.10] 22 [0.87]
40 [1.57]
58 [2.28]
32 [1.18]
66 [2.59] 50 [1.97]
38 [1.49]
46 [1.81]
DC5A1G1_0000000 - 01/22
S5AV-P/01
H22 Pump and controls dimensions S5AV 075/093
S5AV 075/093 Pump - Mounting flange SAE D 4 Bolts - PCXXX (CTP) Control
DETTAGLIO X
DETAIL X
271.1 [10.67] 27.8 [1.094] M12
135.7 [5.34]
20 [0.78] Prof.
Depht
235.1 [9.256]
57.2 [2.251]
6]
56.5 [2.224]
9
qmin
.9
[8
R1
.5
28
191 [7.52]
ø25 [0.98]
ø2
A,B
M1
DETTAGLIO Y
A,B DETAIL Y
ø152.4 [6.00]
200 [7.87]
W
(SAE-D)
50.8 [2.000]
S
M2
135.7 [5.34]
88.9 [3.500]
45 [1.772]
ø2
73 [2.874]
1[
0.8
3]
R2 qmax T1 M12 210 [8.27]
ø63 [2.48]
20 [0.78] Depht
222.6 [8.764]
235.6 [9.275]
VISTA W VISTA W
VIEW W VIEW W
TARATURA REGOLATORE CTP TARATURA REGOLATORE CTP
19 [0.75]
CTP CONTROL SETTING CTP CONTROL SETTING
12.7 [0.500]
45 [1.772]
45 [1.772]
147.8 [5.819] Y
T2
T2 T2
M1 M1
B S S A
M2 M2
147.8 [5.819]
T2 82.5 [3.25]
82.5 [3.25] 82.6 [3.25] 82.6 [3.25]
X
ROTAZIONE DESTRA ROTAZIONE SINISTRA
CLOCKWISE ROTATION COUNTER-CLOCKWISE ROTATION
S5AV 075/093 Pump - Mounting flange SAE C 2 Bolts - PCXXX (CTP) Control
271.3 [10.68]
19 [0.75]
12.7 [0.500]
17.5 [0.69]
191 [7.52]
200 [7.87]
ø127 [5.00]
(SAE-C)
127.3 [5.01]
A,B
210 [8.27]
DC5A1G1_0000000 - 01/22
S5AV-P/01
Pump and controls dimensions S5AV 075/093 H23
S5AV 075/093 Pump - Mounting flange SAE D 4 Bolts - LSPCX - LSPCY (CLS+TP) Control
174.5 [6.87]
191 [7.52]
LS: Load Sensing Pressure port - 1/8 G (BSPP) Deep 10 [0.393]
Y1: Remote port - 1/8 G (BSPP) Deep 10 [0.393]
For the ports not showed please to make reference to PCXXX Control
S5AV 075/093 Pump - Mounting flange SAE D 4 Bolts - NLP0X-NLP1X (NC+LS+TP3) Control
167.5 [6.594]
TARATURA REGOLATORE NC
NC CONTROL SETTING
S A,B
A,B
73 [2.874]
M2
235.8 [9.283]
247.3 [9.736]
39.5 [1.555]
212.3 [8.358]
M1
G
DC5A1G1_0000000 - 01/22
S5AV-P/01
H24 Pump and controls dimensions S5AV 075/093
S5AV 075/093 Pump - Mounting flange SAE D 4 Bolts - NCPCX (NC+PC) Control
TARATURA REGOLATORE NC
297.1 [11.7] NC CONTROL SETTING TARATURA REGOLATORE PC
PC CONTROL SETTING
169.5 [6.67]
S A,B
A,B
For the ports not showed please to make reference to NLP0X-NLP1X Control
8 Shaft options
7/16” 14 UNC-2B
M12
ø40 [1.574]
M12
DC5A1G1_0000000 - 01/22
S5AV-P/01
Through drive H25
S5AV pump can be supplied with through drive. It is possible use the through drive with a second pump (another S5AV or a pump
of other kind). Available flanges are:
• Standard G2 and G3 gear pump flange
• SAE A, SAE B, SAE B-B, SAE C and SAE C-C flange
• TANDEM flange
The maximum permissible torques on drive shaft of the first pump and the maximum through drive torques are listed in the btables
below.
M1
ME
MC
Size Drive Shaft Drive Shaft max torque ME Through drive max torque MC
Nm [lbf•ft] Nm [lbf•ft]
CBB 170 170
(Ø 25) [125] [125]
S10 300 250
032/045
(15T 16/32 DP) [221] [184]
SAX 210 210
(13T 16/32 DP) [169] [169]
CBC 450 350
(Ø 32) [330] [260]
SAH 800 350
050/063
(W 35x2x30x16x9g) [590] [260]
S11 300 300
(15T 16/32 DP) [220] [220]
CBD 700 610
(Ø 40) [516] [450]
SAL 11850 610
(W 40x2x30x18x9g) [364] [450]
075/093
SAC 950 610
(21T 16/32 DP) [700] [450]
S13 620 610
(14T 12/24 DP) [457] [450]
DC5A1G1_0000000 - 01/22
S5AV-P/01
H26 Through drives dimensions
ø82.6 [3.251]
TO MOUNTING FLANGE
(SAE-A)
N 4 M10
15 [0.59] Depht
SPLINED
SAE A 5/8” 9T 16/32 DP
Size
20 [0.79] 032/045 050/063 075/093
9.5 [0.374] 224.5 260 291.3
106 [4.17]
A mm [in] [8.83] [10.23] [11.46]
A
TO MOUNTING FLANGE
146.6 [5.77]
ø101.6 [4.00]
(SAE-B)
N 2 M12
Size
10 [0.393]
032/045 050/063 075/093
20 [0.79]
SPLINED
224.5 2260 291.3
SAE B 7/8” 13T 16/32 DP A mm [in] [8.83] [10.23] [11.46]
SAE B-B 1” 15T 16/32 DP
A
TO MOUNTING FLANGE
SPLINED
SAE C 1-1/4” 14T 12/24 DP
114.6 [4.51]
Size
050/063 075/093
280 311.3
N 4 FORI M14 N 2 FORI M16
A mm [in] [11.02] [12.25]
N 4 HOLES M14 181 [7.13] N 2 HOLES M16 40 [1.57]
DC5A1G1_0000000 - 01/22
S5AV-P/01
Through drives dimensions H27
G2 Flange
A
TO MOUNTING FLANGE
ø36.5 [1.437]
32.5 [1.28]
71.5 [2.81]
20 [0.79]
G3 Flange
A
TO MOUNTING FLANGE
43 [1.69]
ø50.8 [2.00]
98.5 [3.88]
N 4 M10
224.5 260 291.3
A mm [in] [8.83] [10.23] [11.46]
DC5A1G1_0000000 - 01/22
S5AV-P/01
H28 Tandem combination dimensions
A (MAX)
A (Max) B C
Size mm mm mm
[in] [in] [in]
431 157.5 384
032 T0 / 045 T0 + 032 [16.97] [6.20] [15.12]
WARNING: In combination pump the rear pump can be equipped only with one of the shaft listed in the following table.
For an S5AV 075 / 093 used as 2nd pump is available only the option for SAE-C 2 holes flange.
(SAH)
S5AV 050 / 063 (S10)
1st Pump (S11)
(SAH) (S13)
S5AV 075 / 093 (S10)
(S11) (SAC)
DC5A1G1_0000000 - 01/22
S5AV-P/01
DC5A1G1_0000000 - 01/22
DC5A1G1_0000000 - 01/22
HD1 - Variable displacement axial piston pumps for closed circuit I
1
Index
The HD1 series variable piston pumps for closed loop circuits are axial pistons pumps with swash plate design and through drive
shaft on option. These pumps have been specifically designed for use in closed circuit hydrostatic transmissions. The delivery
is proportional to the rotation speed and the swash plate angle. The delivery increases when swash plate’s angle of inclination
increases from 0 to maximum position. Inverting the swash plate’s angle, the flow direction is inverted. The technical choices allow
the new unit to operate at pressures up to of 450 bar [6525 psi].
DC5A1G1_0000000 - 01/22
HD1-P/01
I General information - Features
2
The pump has two built-in pressure relief valves to protect the circuit from pressure overloads. The charge pump circuit features
a gerotor pump with different displacement on option.
The pump design allows the installation of many accessories, such as:
• Hydraulic pressure compensator standard.
• Electric cut-off valve.
• Combined electric cut-off – hydraulic pressure compensator.
• A wide range of through drive options.
• Charge pump delivery pressure filter.
• Electric or optical clogging sensor on the filter.
Simbology:
N/bar l/min
C [lbf/psi]
Load qmax [U.S. gpm]
Maximum flow
N l/min
Fax max [lbf] Axial pushing load qd [U.S. gpm]
External drain flow
N Nm/bar
Fax max [lbf] Axial pulling load Tk [lbf.ft/psi]
Torque costant
N Nm
Fq [lbf]
Radial load Tnom [lbf.ft]
Maximum torque at pressure cont.
N Nm
Fq max [lbf]
Maximum permissible radial load Tmax [lbf.ft]
Maximum torque at pressure peak
kg·m2 cm3/rev
J [lbf·ft2]
Moment of inertia Vg [in3/rev]
Displacement
kg kW
m [lbs]
Weight Pmax [hp]
Maximum power at pnom
Fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15 ÷ 40 cSt. For short periods and upon cold start, a max.viscosity of 800 cSt is allowed.
Viscosities less then 10 cSt are not allowed. A viscosity range of 10 ÷15 cSt is allowed for extreme operating conditions and for
short periods only. For further information see at Fluids and Filtration section.
Operating temperature:
The operating temperature of the oil must be within -25 ºC ÷ 90 ºC (-13 ºF ÷ 194 ºF). The running of the axial piston unit with oil
temperature higher than 90 ºC (194 °F) or lower than -25 ºC (-13 °F) is not recommended. For further information see at Fluids and
filtration section.
DC5A1G1_0000000 - 01/22
HD1-P/01
General information - Features I
3
Filtration:
In the HD1 pump it is possible to provide a filter in the suction line but we recommend to use the optional pressure filter on the
out-let line of the charge pump. The filter on the charge pump out-let line is supplied by Dana while if the filter assembled in the
suction line is used the following recommendation applies:
Install the filter on the suction line of the auxiliary pump. We recommend to use filters with clogging indicator, no by-pass or with
by-pass plugged and filter elementrating of 10 μm absolute. The maximum pressure drop on the filtration element must not exceed
0.2 bar [3 psi]. A correct filtration helps to extend the service life of axial piston units.In order to ensure a correct functioning of the
unit, the max permissible contamination class is 20/18/15 according to ISO 4406:1999.
Suction pressure:
The minimum absolute pressure on the auxiliary pump suction must be of 0.8 bar [11.6 absolute psi]. On cold starting and for
short-periods an absolute pressure of 0.5 bar [7.25 psi] is allowed. In no case inlet pressure can be lower.
Operating pressure:
Main pump: The maximum permissible continuous pressure on pressure ports is 450 bar [6525 psi]. Peak pressure is 480 bar
[6960 psi]. Charge pump: The nominal pressure is 22 bar [319 psi]. Maximum admissible pressure is 30 bar [435 psi].
Seals:
Standard seals used on HD1 pumps are of FKM (Fluoroelastomer). In case of use special fluids, contact Dana.
Displacement limiting:
The pump is equiped with the externally adjustable mechanical displacement limiting device. Displacement limitation is obtained
by means of two setting screws which limit the control piston stroke.
Fq
X/2 X/2
Installation:
HD1 series pumps can be installed in every position or direction. For further details contact Dana.
DC5A1G1_0000000 - 01/22
HD1-P/01
I General information - Features
4
cm3/rev 55
Displacement Vg max [in3/rev] [3.35]
cm3/rev 0
Displacement Vg min [in3/rev] [0]
bar 450
Pressure cont. pnom [psi] [6525]
bar 480
Pressure peak pmax [psi] [6960]
l/min 209
Max flow at nmax qmax [U.S.gpm] [55.2]
Maximum power kW 157
Pmax [hp] [210]
cont.
kW 167
Maximum power int. Pmax [hp] [224]
Max torque cont. Nm 394
Tnom [lbf.ft] [291]
(pnom) at Vgmax
Max torque peak Nm 420
(pmax) at Vgmax Tmax [lbf.ft] [310]
kg·m2 0.0064
Moment of inertia(1) J [lbf.ft2] [0.156]
kg 46
Weight(1) m [lbs] [101.4]
cm3/rev 11 14 18
Displacement charge pump
[in3/rev] [0.67] [0.85] [1.1]
bar 22
Charge pump setting pressure
[psi] [319]
bar 40
Charge pump maximum pressure
[psi] [580]
Maximum Pressure in the housing bar 4
cont. [psi] [58]
bar 6
Maximum Pressure in the housing int
[psi] [87]
Theorical values, without considering the efficency; approximate values. Peak operations must not excide 1% of every minute.
Avoid continuously working at simultaneusly maximum pressure and maximum speed.
Notes:
(1) Approximate values.
DC5A1G1_0000000 - 01/22
HD1-P/01
Ordering code I
5
The following alphanumeric codes system has been developed to identify all of the configuration options for the HD1 pumps.
Use the model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering (as in the example below).
We recommend to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Control feature
Flushing valve
Through drive
Displacement
Charge pump
Pump feature
Shaft end
Painting
Version
Control
Series
Pump
Filter
HD1 P 055 A055 A055 ME 06 13 DX HIR IH 00 25 25 AE PC 000 XX XX XX XXX XX
1
Series
HD1 Variable displacement axial piston pump for closed circuit
2
Pump
P Pump
3
Displacement
055 55 cm3/rev [3.36 in3/rev]
4
Displacement limitation side A
A055 Max displacement 55 cm3/rev [3.36 in3/rev] not adjustable (Standard)
DC5A1G1_0000000 - 01/22
HD1-P/01
I Ordering code
6
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
5
Displacement limitation side B
A055 Max displacement 55 cm3/rev [3.36 in3/rev] not adjustable (Standard)
6
Version
ME ISO
SE SAE
7
Mouting flange
06 SAE-C 2/4 Bolts
8
Shaft end
13 Splined 14T - 12/24 DP
Note:
For Tandem assembly check chapter “TANDEM COMBINATION DIMENSIONS”
9
Direction of rotation (viewed from shaft side)
DX CW
SX CCW
DC5A1G1_0000000 - 01/22
HD1-P/01
Ordering code I
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
10
Control
HLR Manual lever with feed-back
11
Control
Control feature
HLR HIR HIN HER HEN HE2 HEH HFD HME HMI
IH Hydraulic inching — — — — — — — — • •
IM Inching Mechanical inching — — — — — — — — — —
00 Without inching — — — — — — — — • •
12 (V) 12 connector DIN 43650 — — — • — • • — • —
24 (V) 24 connector DIN43650 — — — • — • • — • —
D2 (V) 12 - Deutsch DT04 — — — • — • • — • —
Voltage
D4 (V) 24 - Deutsch DT04 — — — • — • • — • —
N2 (V) 12 AMP JUNIOR — — — — • — — • — —
N4 (V) 24 AMP JUNIOR — — — — • — — • — —
00 mm [in] Without control orifices S • — • • — — • — —
05 mm [in] Ø 0.5 [Ø 0.019] — — • — — — — — — —
06 mm [in] Ø 0.6 [Ø 0.024] — • — • — — — — — —
07 mm [in] Ø 0.7 [Ø 0.027] — • • • — — — — — —
Control orifices diameter (1)
08 mm [in] Ø 0.8 [Ø 0.031] — S S S — — S — — —
09 mm [in] Ø 0.9 [Ø 0.035] — • • — — — — — — —
12 mm [in] Ø 1.2 [Ø 0.047] — • — — — S — — S S
15 mm [in] Ø 1.5 [Ø 0.059] — — — — — — — — • •
(*) Starting speed (rpm) — — — — — — — — • •
(*) Maximum torque speed (rpm) — — — — — — — — • •
(*) Maximum torque value (Nm) — — — — — — — — • •
DC5A1G1_0000000 - 01/22
HD1-P/01
I Ordering code
8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
12
Charge pump
Not Available
00 Without charge pump with Filter and
Automotive control
11 Displacement 11 cm3/rev [0.671 in³/rev]
13
Pressure relief valve side A
25 250 bar [3625 psi]
14
Pressure relief valve side B
25 250 bar [3625 psi]
15
Control
Charge pressure relief valve
HLR HIR HIN HER HEN HE2 HEH HFD HME HMI
AE 20 bar a 1000 rpm [290 psi at 1000 rpm] • • • • • • • — • •
• : Available
– : Not available
DC5A1G1_0000000 - 01/22
HD1-P/01
Ordering code I
9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
16
Control
Pressure compensator valves HLR HIR HIN HER HEN HE2 HEH HFD HME HMI
XX Without Pressure Compensator — — — — — — — — • •
PC Pressure compensator • • • • • • • • — —
17
Compensator
Pressure compensator feature
XX PC EP
000 Feature not necessary • – –
18
• : Available Control
– : Not available Filtro HLR - HIR - HIN - HER
HME - HMI
HEN- HE2 - HEH - HFD
XX Without Filter Standard • •
E2 Electric clogging sensor (8 bar) [116 psi] + DIN 43650 connector with LED 24V • —
E1 Electric clogging sensor (8 bar) [116 psi] + DIN 43650 connector with LED 12V • —
DC5A1G1_0000000 - 01/22
HD1-P/01
I Ordering code
10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
19
Through drive
Through drive for 2nd pump assembled by the customer
SA SAE A = Z9 - 16/32 DP
20
Additional feature
XX Not Required
21
Pump feature
XXX Not Required
22
Painting
XX Not Required
DC5A1G1_0000000 - 01/22
HD1-P/01
Controls
10 Control
The displacement of the pump is directly proportional to the angle of rotation of the lever. The feedback system feels the position
of the swashplate and works automatically to compensate a positioning error. The diagram below shows the relationship between
angle and displacement.
40
30
20 PS GE GA
10 X1
A
Angle (°)
X2
V4
0
V2
R1 R2
-10
V3
-20
-30 B
-40 Z2 Z1 S L1
L2 FA GS GB
-100 -80 -60 -40 -20 0 20 40 60 80 100
40°
40°
60 [2.36]
Note:
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic fluid, abrasion or
residual contamination from system components). As a result, the axial piston unit can no longer supply the flow specified by the operator. Check
whether your application requires that remedial measures be taken on your machine in order to bring the driver consumer into a safe position (e.g.
immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B B
HD1 055
A A
DC5A1G1_0000000 - 01/22
HD1-P/01
I Hydraulic proportional control with feed-back HIR
12
10 Control
The pump displacement is proportional to the pilot pressure on Y1 or Y2 ports, which also affect flow direction. The feedback
system feels the position of the swashplate and works automatically to compensate a positioning error. Piloting can be provided
by boost pressure from GS port. The piloting pressure will have to be controlled then by a joystick or by a pressure reducing valve
(not supplied).
psi bar
290 20
240 16
Y2 Y1
180 12
PS GE GA
120 8
X1
A
60 4
X2
V4
0 0
Pressure (p)
V2
R1 R2
-60 -4
V3
-120 -8
-180 -12
B
-240 -16
L2 FA
-290 -20 Z2 Z1 S L1 GS GB
-100 -80 -60 -40 -20 0 20 40 60 80 100
Note:
The tolerance on piloting pressure is ± 10% of maximum value.
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic fluid, abrasion or
residual contamination from system components). As a result, the axial piston unit can no longer supply the flow specified by the operator. Check
whether your application requires that remedial measures be taken on your machine in order to bring the driver consumer into a safe position (e.g.
immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
Y2 Y2
B B
A A
DC5A1G1_0000000 - 01/22
HD1-P/01
Hydraulic proportional control without feed-back HIN I
13
10 Control
The pump displacement is proportional to the pilot pressure on Y1 or Y2 piloting ports, which also affect flow direction. The flow is
also influenced by the working pressure and by the rotation speed of the pump. With a given input signal (piloting pressure) the
pump can vary the displacement and the flow when working pressure or rotating speed change. Feeding pressure to the control
joystick can be provided by charge pressure from GS port. The piloting pressure must then be controlled by said joystick or by
a pressure reducing valve (not supplied). The orifice dimensions must be choosed in function of the response time required, see
the table below.
Warning:
Use of the HIN control can require a review of the motor engine and vehicle parameters to ensure that the pump is set up
correctly. We recommend that all HIN applications be reviewed by a Dana. In case, please contact our technical service.
psi bar
Y2 Y1
290 20
240 16
180 12
120 PS GE GA
8
Pressure (p)
60 4 X1
A
X2
0 0 V4
-60 -4 V2
R1 R2
-120 -8 V3
-180 -12
-240 -16 B
-290 -20 L2 FA
-100 -80 -60 -40 -20 0 20 40 60 80 100 Z2 Z1 S L1 GS GB
Note:
The tolerance on piloting pressure is ± 10% of maximum value.
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
Y2 Y2
B B
A
A
DC5A1G1_0000000 - 01/22
HD1-P/01
I Electric proportional control with feed-back HER
14
10 Control
The displacement of the pump is directly proportional to the input current of one of the two proportional solenoids. The feedback
system feels the position of the swashplate and works automatically to compensate a positioning error. The input current of the
two proportional solenoids must be controlled by an external amplifier card and it is recommended to use our amplifier specific
for HD1. Flow direction depends on which solenoid is energized. Standard solenoids are proportional at 24V d.c. max. current 1A.
(Optional solenoids 12V d.c. max. current 2A). For emergency operation only it is however possible to control solenoids directly
with 24V d.c.voltage (or 12V d.c.), by-passing the amplifier.
1200
1000
800
600
PS GE GA
400 12V
Current (mA)
X1
A
200 24V
X2
V4
0
V2
-200 24V R1 R2
V3
-400 12V
-600
B
-800
-1000 L2 FA
Z2 Z1 S L1 GS GB
-1200
-100 -80 -60 -40 -20 0 20 40 60 80 100
Solenoid 24V:
Current min. 200 mA max 600 mA
Solenoid 12V:
Current min. 400 mA max 1200 mA
Note:
The tolerance on piloting current is ± 10% of maximum value.
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic fluid, abrasion or
residual contamination from system components). As a result, the axial piston unit can no longer supply the flow specified by the operator. Check
whether your application requires that remedial measures be taken on your machine in order to bring the driver consumer into a safe position (e.g.
immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B B
A A
DC5A1G1_0000000 - 01/22
HD1-P/01
Electric proportional control without feed-back HEN I
15
10 Control
The displacement of the pump is directly proportional to the input current of one of the two proportional solenoids. The flow is also
influenced by the working pressure and by the rotation speed of the pump. With a given input signal (piloting current) the pump
can vary the displacement and the flow when working pressure or rotating speed change. The input current of the two proportional
solenoids must be controlled by an external amplifier card and it is recommended to use our amplifier specific for HD1. Flow
direction depends on which solenoid is energized. Standard solenoids are proportional 24V d.c. max. current 1A. (Optional
solenoids 12V d.c. max. current 2A). For emergency operation only it is however possible to control solenoids directly with 24V
d.c.voltage (or 12V d.c.), by-passing the amplifier.
Warning:
Use of the HEN control can require a review of the motor engine and vehicle parameters to ensure that the pump is set up
correctly. We recommend that all HEN applications be reviewed by a Dana. In case, please contact our technical service.
1400
1200
1000
800
600 12V
PS GE GA
400
Current (mA)
24V X1
200 A
X2
0 V4
-200 V2
R1 R2
24V
-400
V3
-600 12V
-800
B
-1000
-1200 L2
Z2 Z1 S L1 FA GS GB
-1400
-100 -80 -60 -40 -20 0 20 40 60 80 100
Solenoid 24V:
Current min. 300 mA max 650 mA
Solenoid 12V:
Current min. 600 mA max 1300 mA
Note:
The tolerance on piloting current is ± 10% of maximum value.
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
S2 S2
B B
A A
DC5A1G1_0000000 - 01/22
HD1-P/01
I Electric on-off HE2
16
10 Control
Switching one of the solenoids the pump swivels to maximum displacement in the corresponding output flow direction.
Switching off the stated solenoid will result in swivelling back the pump to zero displacement position.
PS GE GA
X1
A
X2
V4
V2
R1 R2
V3
L2 FA
Z2 Z1 S L1 GS GB
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B B
A A
DC5A1G1_0000000 - 01/22
HD1-P/01
Electric proportional control with hydraulic emergency override HEH I
17
10 Control
This control has the same electric proportional features of HER control, but it also has an emergency hydraulic proportional control
capability when a pilot pressure on Y1 and Y2 ports. The input current of the two proportional solenoids must be controlled by an
external amplifier card and it is recommended to use our amplifier specific for HD1. Hydraulic operation of HEH control is meant
to be an emergency device to control displacement of the pump in case of a breakdown of the electric circuit. A pilot pressure of
22 bar [319 psi] is required to swivel the pump to max displacement in emergency operation.
Y2 Y1
PS GE GA
X1
A
X2
V4
V2
R1 R2
V3
L2 FA
Z2 Z1 S L1 GS GB
Warning:
Y1 and Y2 ports must not have any back pressure during normal electric control operation (vented to tank).
Note:
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic fluid, abrasion or
residual contamination from system components). As a result, the axial piston unit can no longer supply the flow specified by the operator. Check
whether your application requires that remedial measures be taken on your machine in order to bring the driver consumer into a safe position (e.g.
immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B B
A A
DC5A1G1_0000000 - 01/22
HD1-P/01
I Electric fun drive control HFD
18
10 Control
Pump displacement
100
80
60 PS GE GA
40 X1
A
Vg max (%)
20 X2
V4
0
V2
R1 R2
-20
V3
-40
-60
-80 B
-100
L1 L2 FA
0 10 20 30 40 50 60 70 80 90 100 Z2 Z1 S GS GB
I max (%)
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
Flow direction depending to the I max current value.
S1 S1
Flow direction
B B
S1 < 85% I max
DC5A1G1_0000000 - 01/22
HD1-P/01
Automotive HME-HMI I
19
10 Control
The “AUTOMOTIVE” (speed related) control, is used in hydrostatic transmissions with closed loop variable displacement pumps.
This kind of controls allows to:
• Control of the vehicle translation speed;
• Limit the amount of Torque required from the Engine;
• Inching of the vehicle speed. The control of the Inching valve can be done with an hydraulic signal (Minimum 12 bar [174 psi] is
required to swivel the pump to null displacement) or with a lever.
• Possibility to control the direction of flow electrically (HME) and hydraulically (HMI).
V2
+
HM without VSC
HME
St
Pi
VS In
VT
PS GE GA
X1
A
X2 VC
V4
V2
V3
L2 FA
Z2 Z1 S L1 GS GB
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
Y1 S1 Y1
Y2 Y2 S1
S2 S2
B B B B
A A A A
DC5A1G1_0000000 - 01/22
HD1-P/01
I Pressure compensator valves PC-EP
20
PC Pressure compensator
The pressure compensator valve is meant to avoid opening of the relief valves: whenever working pressure reaches the PC valve
setting, the swashplate is swivelled back reducing flow. The valve allows to maintain a costant pressure in the circuit at the setting
value. It is advisable to fit the cut-off valve to all system where pressure peaks close to the relief valves setting value occur or in
hydraulic systems engineered to the maximum pump pressure. It is recommended to set the pressure cut-off valve at 30 bar [435
psi] lower than the high pressure relief valve setting. Setting range:100÷430 bar [1450÷6237 psi].
Note:
The pressure compensator valve is standard on HD1 pump and it can be combined with TE (EP) valve.
PS GE GA
X1
A
X2
V4
V2
R1 R2
V3
L2 FA
Z2 Z1 S L1 GS GB
The electric cut-off valve swivels back to zero the pump flow when power supply to the ON/OFF solenoid is cut-off. This valve has
been designed for applications subject to safety rules, which required stopping of the machine in case of no electric signal. Feed
voltage is 24V d.c.
GE GA
PS
X1
A
X2
V4
V2
R1 R2
V3
L1 L2 FA
Z2 Z1 S GS GB
DC5A1G1_0000000 - 01/22
HD1-P/01
Angle swivel indicator ASI I
21
21 Pump feature
GA
Y2 Y1
PS GE GA
X1
A
X2
V4
A
V2
R1 R2
V3
B
B
GB Ua L1 L2 FA
Z2 Z1 S GS GB
Output Voltage
Features Range
Flow Operating Output Supply Voltage Ub 9 to 30 V DC
direction Pressure Voltage
0.5 V 2.5 V 4.5 V
Output Voltage Ua
B to A Gb > 2.5 (Vg max) (Vg 0) (-Vg max)
CW
Shaft direction A to B Ga < 2.5 Reverse voltage protection Short circuit-resistance
of Rotation A to B Ga > 2.5 Operating temperature range -40 °C to +140 °C
CCW
B to A Gb < 2.5 Vibration resistance BS EN 60068-2-64:1995
Sinusoidal vibration Sec 8.4(31.4gn rms)
EN 60068-2-6 20 to 2000Hz random
Shock resistance
3m drop onto concrete
Continuous shock
Mid point of And 2500g
IEC 68-2-29
electrical angle
Output increases Output increases Type of protection IP68 (to 2m depth for 1 hour)
for CW unit when for CCW unit when DIN/EN 60529 and IP69K
viewed as shown viewed as shown
pin 3 pin 4
pin 2 pin 1
DC5A1G1_0000000 - 01/22
HD1-P/01
I Pressure filter
22
18 Filter
In order to guarantee an optimum fluid contamination level in the closed loop the HD1 can be equipped with a filter positioned
on the delivery outlet of the charge pump. Only the flow necessary to reintegrate the lost oil due to leakage will pass through the
filter, all the excess flow is not filtered and discharged through the pump drain line. In this way a longer life of the filter is achieved.
The filter contains a composite fibre filtering element, with capacity of 12 micron absolute. The system uses sensors of clogging
differential pressure of 8 bar [116 psi]) in optical and electrical (Connector DIN43650/ISO4400) version.
It is available a conversion cable from DIN43650/ISO4400 to Deutsch DT04 connector code M54050011. The filter is without by-pass.
It is available a version for filtering in filter pressure not mounted on the pump. It’s available also version:
• FP arranged for filter
• FR with openings for external filter under pressure
GE GF
PS GA
X1
A
X2
V4
V2
R1 R2
V3
L2 FA
Z2 Z1 S L1 GB
1 N.A. 3
2 N.C.
GE GF
PS GA
X1
A
X2
V4
V2
R1 R2
V3
L2 FA
Z2 Z1 S L1 GB
DC5A1G1_0000000 - 01/22
HD1-P/01
Pressure filter I
23
FR Remote filter
Non fornito
Not supplied
GE IN OUT
PS GA
X1
A
X2
V4
V2
R1 R2
V3
L2 FA
Z2 Z1 S L1 GB
Non fornito
Not supplied
IN OUT
PS GE GF GS GA
X1
A
X2
V4
V2
R1 R2
V3
L2 FA
Z2 Z1 S L1 GB
DC5A1G1_0000000 - 01/22
HD1-P/01
I By-pass valve
24
21 Pump feature
By-pass function: 2
- Take out the cap 1; Ch=5
- Unscrew the valve 2 max 5 turns.
Y2 Y1
PS GE GA
X1
A
X2
V4
V2
R1 R2
V3
L2 FA
Z2 Z1 S L1 GS GB
DC5A1G1_0000000 - 01/22
HD1-P/01
Shafts dimensions I
25
8 Shaft end
AC Splined 13 Splined
SAE 1-1/4” 21T 16/32 - FLAT ROOT CLASS 5 ANSI B92.1a - 1976 14T 12/24 DP - FLAT ROOT CLASS 5 ANSI B92.1a - 1976
35 [1.36]
32 [1.24]
40 [1.56]
40 [1.59]
48 [1.89]
48.1 [1.89]
56 [2.20]
56 [2.20]
E
F
mm [inch]
Type ØA ØB ØC ØD E F
34
AC 21T 16/32” DP
35 [1.34] 127 72 12.7 7.9
[1.38] 32.9 [5.08] [2.83] [0.50] [0.31]
ØD
ØC
13 14T 12/24” DP
[1.30]
Coupling hub
ØB
ØA
To avoid dangerous contacts, the external diameter of the hub must be less than the diameter dimension “ØD” while the internal
diameter must be less than the diameter “ØB”.
DC5A1G1_0000000 - 01/22
HD1-P/01
I Pump and controls dimensions
26
10 Control
HLR
223.5 [8.80]
226.5 [8.92]
228.5 [9.00]
FA GS
GA 27.8 [1.09]
11 [0.43]
Ø2
4 [0.16]
65 [2.56] 25.5 [1.00]
6 [Ø
123 [4.84]
1.0
105.9 [4.17] 119.2 [4.69] 93 [3.66]
123 [4.84]
2]
12.7 [0.50]
14.3 [0.56]
57.2 [2.25]
167.2 [6.58]
166.2 [6.54]
X1 B X2
44 [1.73]
20 [0.79]
76 [2.99]
76 [2.99]
Ø127 [5.00]
10 [0.39]
17.5 [0.69]
44 [1.73]
20 [0.79]
47.5 [1.87]
57.2 [2.25]
93 [3.66]
88.8 [3.50]
L1 GE
114.5 [4.51] A L2
55.4 [2.18] 241.5 [9.51]
181 [7.13]
223.5 [8.80] Flange
212 [8.35]
SAE J744
N°8 7/16 14-UNC-2B SAE
78.5 [3.09] N°8 M12 ISO
prof/depth 20 [0.78]
65 [2.56] 25 [0.98]
GB PS
20 [0.79]
284.5 [11.20]
Ø8
[0.3
241.5 [9.51]
1]
233.5 [9.19]
223.5 [8.80]
207.7 [8.18]
93 [3.66]
mm [inch]
Z2 S Z1
59 [2.32] 59 [2.32]
DC5A1G1_0000000 - 01/22
HD1-P/01
Pump and controls dimensions I
27
10 Control
HIR
D
E
A B
Y1 Y2
mm [inch]
A 56.5 [2.22]
B 56.5 [2.22]
C
F
C 159.1 [6.26]
D 174 [6.85]
E 140.2 [5.52]
F 123.3 [4.93]
Y1, Y2: control piloting pressure ports -1/4 G (BSPP) (ISO) - 7/16” - 20 UNF 2B (SAE)
HIN
D
E
A B
Y1 Y2
mm [inch]
A 33.8 [1.33]
F
C
B 39.7 [1.56]
C 137 [5.39]
D 174 [6.35]
E 127.5 [5.02]
F 121 [4.76]
Y1, Y2: control piloting pressure ports -1/4 G (BSPP) (ISO) - 7/16” - 20 UNF 2B (SAE)
A
B C E
Connector
DIN43650 (ISO4400) F
mm [inch]
A 195 [7.63]
B 67.4 [2.65]
G
D
C 67.4 [2.65]
D 159.1 [6.26]
E 174 [6.85]
F 140.2 [5.52]
G 153.3 [6.04]
DC5A1G1_0000000 - 01/22
HD1-P/01
I Pump and controls dimensions
28
10 Control
HER - DT04
D
A B E
Connector
DT04
mm [inch]
A 85.5 [3.37]
C
B 85.5 [3.37]
F
C 162.4 [6.33]
D 174 [6.85]
E 140.2 [5.52]
F 151.2 [3.95]
HEN
D
E
A B
Connector
AMP-Junior-Timer mm [inch]
A 108.2 [4.26]
B 101.1 [3.98]
C
C 129.4 [5.09]
D 175 [6.89]
E 141 [5.55]
F 114.4 [4.50]
HE2
Connector DIN 43650 (ISO 4400)
A C
D
mm [inch]
B
A
E
188.3 [7.41]
B 185.5 [7.30]
C 174 [6.85]
D 128.5 [5.06]
E 174.4 [6.87]
DC5A1G1_0000000 - 01/22
HD1-P/01
Pump and controls dimensions I
29
10 Control
HEH - DT04
A E
Connector
Y1 B Y2 F DT04
C
mm [inch]
A 241.8 [9.52]
D
G
B 207 [8.15]
C 95 [3.74]
D 162.6 [6.40]
E 174 [6.85]
F 140.2 [5.52]
G 151.2 [5.99]
Y1, Y2: control piloting pressure ports -1/8” G (BSPP) (ISO) - 5/16” - 24 UNF (SAE)
A E
Connector
Y1 B Y2 F DIN43650 (ISO 4400)
C
mm [inch]
A 239.8 [9.44]
D
B 171.7 [6.76]
C 95 [3.74]
D 152.9 [6.02]
E 174 [6.85]
F 140.2 [5.52]
Y1, Y2: control piloting pressure ports -1/8” G (BSPP) (ISO) - 5/16” - 24 UNF (SAE)
HFD
D
E
A B
Connector
AMP-Junior
mm [inch]
A 108.2 [4.26]
B 93.2 [3.67]
C
C 114.4 [4.50]
D 175 [6.83]
E 141 [5.55]
F 129.4 [5.09]
DC5A1G1_0000000 - 01/22
HD1-P/01
I Pump and controls dimensions
30
10 Control
HME Automotive
116 [4.57]
156 [6.14]
140 [5.51]
203.7 [8.02]
171.5 [6.75]
247.7 [9.75]
In
185.9 [7.32]
60 [2.36]
38 [1.50]
126 [4.96]
Pi
98 [3.86]
85.8 [3.38]
21.2 [0.83]
78.5 [3.09]
mm [inch]
DC5A1G1_0000000 - 01/22
HD1-P/01
Pump and controls dimensions I
31
10 Control
HME Automotive
116 [4.57]
156 [6.14]
203.7 [8.02]
171.5 [6.75]
247.7 [9.75]
In
60 [2.36]
157.6 [6.21]
126 [4.96]
38 [1.50]
Pi
98 [3.86]
85.8 [3.38]
21.2 [0.83]
Thermostatic valve VT
109 [4.29] 117 [4.61]
121.5 [4.78]
129 [5.08]
234.7 [9.24]
156 [6.14]
203.7 [8.02]
Starting control valve ST 183.2 [7.21]
Y1
116 [4.57]
78.5 [3.09]
mm [inch]
Y2
DC5A1G1_0000000 - 01/22
HD1-P/01
I Pump and accessories dimensions
32
Electric Cut-Off +
EP Pressure Compensator valve
C
A D
B E
mm [inch]
A 154.1 [6.07]
B 141.7 [5.58]
C 56.9 [2.24]
D 25 [0.98]
G
F
E 5.3 [0.21]
F 201 [7.91]
G 216 [8.50]
DC5A1G1_0000000 - 01/22
HD1-P/01
Pump and accessories dimensions I
33
18 Filter
mm [inch]
GF
1/4” G (BSPP) UNI/ISO 228/1
GE
Depth 12 [0.47]
H
GF
F
ISO
GF
GE 7/16”-20 UNF-2B ISO 11926
G
Depth 12 [0.47]
B
GE
19°
SAE
C A 110 [4.33]
D
GF: Boost pressure B 81.4 [3.21]
E
GE: Working pressure
C 47.4 [1.87]
D 250.8 [9.87]
E 258.8 [10.19]
F 18.9 [0.74]
G 1.6 [0.06]
H 102.1 [4.02]
K
J
I 179 [7.05]
I
J 140.5 [5.53]
K 128 [5.04]
mm [inch]
GF
GF 1/4” G (BSPP) UNI/ISO 228/1
F
GE
A
Depth 12 [0.47]
ISO
G
GF
B
GE
19° GE 7/16”-20 UNF-2B ISO 11926
Depth 12 [0.47]
C SAE
GF: Boost pressure
D
A 72 [2.83]
E
GE: Working pressure B 81.4 [3.21]
C 47.4 [1.87]
D 250.8 [9.87]
E 258.8 [10.19]
F 18.9 [0.74]
G 1.6 [0.06]
K
J
I 179 [7.05]
I
J 140.5 [5.53]
K 128 [5.04]
DC5A1G1_0000000 - 01/22
HD1-P/01
I Pump and accessories dimensions
34
18 Filter
E mm [inch]
F
OUT A
IN
1/2” G (BSPP) UNI/ISO 228/1
GE OUT Depth 18 [0.71]
ISO
IN
3/4’’ - 16 UNF-2B ISO R725
OUT Depth 15 [0.59]
IN SAE
GE 1/4” G (BSPP) UNI/ISO 228/1
ISO Depth 12 [0.47]
B
GE
C
A -0.2 [-0.01]
B 243.5 [9.59]
C 206.5 [8.13]
D 226.5 [8.92]
E 132.9 [5.23]
IN: Return from the filter F 116.9 [4.60]
OUT: Flow to the filter
GE: Working pressure
A
B E
mm [inch]
GS GE
GS
GE 1/4” G (BSPP) UNI/ISO 228/1
GF Depth 12 [0.47]
GF
ISO
GS
GE 7/16”-20 UNF-2B ISO 11926
GF Depth 12 [0.47]
D
C
SAE
A 10 [0.39]
B 5 [0.20]
C 226.8 [8.93]
D 241.5 [9.51]
E 98 [3.86]
DC5A1G1_0000000 - 01/22
HD1-P/01
Pump and accessories dimensions I
35
21 Pump feature
A B
mm [inch]
A 83 [3.27]
C
B 69 [2.72]
C 241.5 [9.51]
DC5A1G1_0000000 - 01/22
HD1-P/01
I Through drives
36
19 Through drives
HD1 pump can be supplied with through drive. The through drive can driving with a second HD1 or a pump of other kind.
Available flanges are:
• SAE A, SAE B, SAE C, SAE B-B and SAE C-C flange
• TANDEM flange
The maximum permissible torques on drive shaft of the first pump and the maximum through drive torques are listed in the table
below.
Warning:
The effective torque value on the shaft of first pump is given by the sum of the torques required from each pump making the
system.
M1
ME
MC
Drive shaft
AC 13
(Z21 16/32 DP) (Z14 12/24 DP)
Nm 950 620
Drive shaft max torque ME
[lbf·ft] [700] [457]
Nm 522 522
Through drive max torque MC
[lbf·ft] [385] [385]
DC5A1G1_0000000 - 01/22
HD1-P/01
Tandem combination dimensions I
37
19 Through drives
HD1 05 5 H
577 [ 22.72] 625.6 [24.63]
AC 13
Shafts
13 13
Warning: the TC-TX through drives must be used in the configuration of the first pump in the following cases:
1. Tandem pump combination.
2. Dana second pump
Example:
• If it is needed to purchase a single pump for Tandem pump combination, the pump will must have the TC through drive.
DC5A1G1_0000000 - 01/22
HD1-P/01
I Through drives dimensions
38
19 Through drives
Type mm [inch]
E (Ø)
Dept 16 [0.63]
B
3/8” 16 UNC-2B
SAE Dept 16 [0.63]
A
C 106.4 [4.19]
D 296.5 [11.67]
B
n.2 holes E 82.55 [3.25]
OR 2.62x82.22 (2-152)
SA 14.5 [0.57]
C F F
AA 14.5 [0.57]
Type mm [inch]
D
SB SAE B - 7/8” -13T 16/32 DP
A
BB SAE BB - 1” - 15T 16/32 DP
E (Ø)
M12
ISO Dept 19 [0.75]
B
1/2” 13 UNC-2B
A SAE Dept 19 [0.75]
C 146 [5.75]
B D 296.5 [11.67]
n.2 holes
OR 2.62x101.27 (2-155) E 101.6 [4.00]
C F SB 17.1 [0.67]
F
BB 15.1 [0.59]
DC5A1G1_0000000 - 01/22
HD1-P/01
Through drives dimensions I
39
19 Through drives
SC SAE C Flange
Type mm [inch]
G (Ø)
Dept 30 [1.18]
3° *
M12
ISO Dept 21 [0.83]
A C
1/2” 13 UNC-2B
SAE Dept 21 [0.83]
D
B
D 114.5 [4.51]
n.2 holes OR 3.53x126.6 (2-250) E 181 [7.13]
3° *
C F 292.5 [11.52]
D H
n.4 holes
E G 127 [5.00]
H 18.1 [0.71]
DC5A1G1_0000000 - 01/22
HD1-P/01
DC5A1G1_0000000 - 01/22
S6CV - Variable displacement axial piston pumps for closed circuit L1
Indice
The S6CV series variable piston pumps for closed loop circuits are axial pistons pumps with swash plate design and through drive
shaft on option. These pumps have been specifically designed for use in closed circuit hydrostatic transmissions. The delivery
is proportional to the rotation speed and the swash plate angle. The delivery increases when swash plate’s angle of inclination
increases from 0 to maximum position. Inverting the swash plate’s angle, the flow direction is inverted. The technical choices allow
the new unit to operate at pressures up to of 400 bar [5800 psi].
DC5A1G1_0000000 - 01/22
S6CV-P/01
L2 General information - Features
The pump has two built-in pressure relief valves to protect the circuit from pressure overloads. The charge pump circuit features a
gerotor pump with different displacement on option.
The pump design allows the installation of many accessories, such as:
• Hydraulic pressure compensator.
• Electric cut-off valve.
• Combined electric cut-off – hydraulic pressure compensator.
• A wide range of through drive options.
• Charge pump delivery pressure filter.
• Electric or optical clogging sensor on the filter.
Simbology:
N/bar l/min
C [lbf/psi]
Load qmax [U.S. gpm]
Maximum flow
N l/min
Fax max [lbf]
Axial pushing load qd [U.S. gpm]
External drain flow
N Nm/bar
Fax max [lbf]
Axial pulling load Tk [lbf.ft/psi]
Torque costant
N Nm
Fq Radial load Tnom [lbf.ft]
Maximum torque at pressure cont.
[lbf]
N Nm
Fq max Maximum permissible radial load Tmax [lbf.ft]
Maximum torque at pressure peak
[lbf]
kg·m2 cm3/rev
J Moment of inertia Vg [in3/rev]
Displacement
[lbf·ft2]
kg kW
m Weight Pmax [hp]
Maximum power at pnom
[lbs]
n0 max rpm Maximum speed ηhm % Mech-hyd. efficiency
Fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15 ÷ 40 cSt. For short periods and upon cold start, a max.viscosity of 800 cSt is allowed.
Viscosities less then 10 cSt are not allowed. A viscosity range of 10 ÷15 cSt is allowed for extreme operating conditions and for short
periods only. For further information see at Fluids and Filtration section.
Operating temperature:
The operating temperature of the oil must be within -25 ºC ÷ 90 ºC (-13 ºF ÷ 194 ºF). The running of the axial piston unit with oil
temperature higher than 90 ºC (194 °F) or lower than -25 ºC (-13 °F) is not recommended. For further information see at Fluids and
filtration section.
DC5A1G1_0000000 - 01/22
S6CV-P/01
General information - Features L3
Filtration:
In the S6CV pump it is possible to provide a filter in the suction line but we recommend to use the optional pressure filter on the out-
let line of the charge pump. The filter on the charge pump out-let line is supplied by Dana while if the filter assembled in the suction
line is used the following recommendation applies:
Install the filter on the suction line of the auxiliary pump. We recommend to use filters with clogging indicator, no by-pass or with
by-pass plugged and filter elementrating of 10 μm absolute. The maximum pressure drop on the filtration element must not exceed
0.2 bar [3 psi]. A correct filtration helps to extend the service life of axial piston units.In order to ensure a correct functioning of the
unit, the max.permissible contamination class is 20/18/15 according to ISO 4406:1999.
Suction pressure:
The minimum absolute pressure on the auxiliary pump suction must be of 0.8 bar [11.6 absolute psi]. On cold starting and for short-
periods an absolute pressure of 0.5 bar [7.25 psi] is allowed. In no case inlet pressure can be lower.
Operating pressure:
Main pump: The maximum permissible continuous pressure on pressure ports is over 400 bar [5800 psi]. Peak pressure is 450 bar
[6525 psi]. Charge pump: The nominal pressure is 22 bar [319 psi]. Maximum admissible pressure is 40 bar [580 psi].
Seals:
Standard seals used on S6CV pumps are of FKM (Viton ®). In case of use special fluids, contact Dana.
Displacement limiting:
The pump is equiped with the externally adjustable mechanical displacement limiting device. Displacement limitation is obtained by
means of two setting screws which limit the control piston stroke.
Fq Displacement
+ Fax
075 128
- Fax Radial load Fq max N [lbf] 2400 [540] 4600 [1035]
Installation:
S6CV series pumps can be installed in every position or direction. For further details contact Dana.
DC5A1G1_0000000 - 01/22
S6CV-P/01
L4 General information - Features
Displacement
075 128
cm3/rev 75(1) 128 (1)
Displacement Vg max
[in3/rev] [4.57] (1) [7.8] (1)
cm3/rev 0 0
Displacement Vg min
[in3/rev] [0] [0]
bar 400 400
Pressure cont. pnom
[psi] [5800] [5800]
bar 450 450
Pressure peak pmax
[psi] [6525] [6525]
Theorical values, without considering the efficency; approximate values. Peak operations must not excide 1% of every minute. Avoid
continuously working at simultaneusly maximum pressure and maximum speed.
Notes:
(1) For 075 displacement it is possible to achieve the displacement 81 cm3/rev [4.941 in3/rev]. For 128 displacement it is possible to achieve the
displacement 136 cm3/rev [8.296 in3/rev]. Please contact our technical service for the technical specifications.
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Ordering code L5
The following alphanumeric codes system has been developed to identify all of the configuration options for the S6CV 75 pumps.
Use the model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering. We recommend to carefully read the catalogue
before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Control feature
Flushing valve
Through drive
Displacement
Charge pump
Pump feature
Shaft end
Painting
Version
Control
Flange
Series
Pump
Filter
S6CV P 075 60 60 ME 06 AC DX HME 24 00 25 25 AF PC 000 XX XX XX XXX 01
1
Series
S6CV Variable displacement axial piston pump for closed circuit
2
Pump
P Pump
3
Displacement
075 75 cm3/rev [4.575 in3/rev]
4
Displacement limitation side A
0+81 From 0 cm /rev to 81 cm3/rev [4.940 in3/rev]
3
5
Displacement limitation side B
0+81 From 0 cm3/rev to 81 cm3/rev [4.940 in3/rev]
DC5A1G1_0000000 - 01/22
S6CV-P/01
L6 S6CV 075 - Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
6
Version
ME ISO
SE SAE
7
Mouting flange
06 SAE-C 2/4 Bolts
Note:
For Tandem assembly check chapter “TANDEM COMBINATION DIMENSIONS”
8
Shaft end
13 Splined 14T - 12/24 DP
9
Direction of rotation (viewed from shaft side)
DX CW
SX CCW
10
Control
HLR Manual lever with feed-back
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Ordering code L7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
11
Control
Control features
HLR HIR HIN HER HEN HE2 NEH HME HMI
IH Hydraulic inching – – – – – – – • •
IM Inching Mechanical inching – – – – – – – – –
00 Without inching – – – – – – • •
12 (V) 12 connector DIN 43650 – – – • • • • • –
24 (V) 24 connector DIN43650 – – – • • • • • –
Voltage
D2 (V) 12 - Deutsch DT04 – – – • – • • • –
D4 (V) 24 - Deutsch DT04 – – – • – • • • –
00 mm [in] Without control orifices S • – • – – – – –
05 mm [in] Ø 0.5 [Ø 0.019] – – • – – – – – –
06 mm [in] Ø 0.6 [Ø 0.024] – • – • – – – – –
07 mm [in] Ø 0.7 [Ø 0.027] – • • • – – – – –
08 mm [in] Ø 0.8 [Ø 0.031] – S S S S – S – –
Control orifices diameter (1)
H8 mm [in] Ø 0.8 [Ø 0.031] – • – – – – – – –
09 mm [in] Ø 0.9 [Ø 0.035] – • • – – – – – –
12 mm [in] Ø 1.2 [Ø 0.047] – • – – – S – S S
15 mm [in] Ø 1.5 [Ø 0.059] – – – – – – – • •
20 mm [in] Ø 2.0 [Ø 0.0787] – – – • – – – – –
(*) Starting speed (rpm) – – – – – – – • •
(*) Maximum torque speed (rpm) – – – – – – – • •
(*) Maximum torque value (Nm) – – – – – – – • •
(*) Supply the setting value.
• : Required
– : Not required
S: standard
(1)
in case of the different response times, please you contact sales office
12
Charge pump
00 Without charge pump
18 Displacement 18 cm3/rev [1.098 in3/rev] Standard
23 Displacement 23.1 cm /rev [1.41 in /rev]
3 3
13
Pressure relief valve side A
25 250 bar [3625 psi]
30 300 bar [4350 psi]
35 350 bar [5075 psi]
42 420 bar [6090 psi] Standard
DC5A1G1_0000000 - 01/22
S6CV-P/01
L8 S6CV 075 - Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
14
Pressure relief valve side B
25 250 bar [3625 psi]
15
Charge pressure relief valve
AE 20 bar a 1000 rpm [290 psi at 1000 rpm]
16
Control
Pressure compensator and Cut-Off valves
HLR HIR HIN HER HEN HE2 NEH HME HMI
XX Without pressure compensator Standard • • • • • • • • •
PC Pressure compensator • • • • • • • – –
TE Electric Cut-Off • • • • • • • – –
• : Available
– : Not available
17
Cut-Off valves
Cut-Off valves feature
XX PC TE EP
000 Feature not necessary • – – –
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Ordering code L9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
18
Regolatore
Filtro
HLR HIR HIN HER HEN HE2 HEH HME HMI
XX Without Filter Standard • • • • • • • • •
M8 Optical clogging sensor (8 bar) [116 psi] • • • • • • • – –
E2 Electric clogging sensor (8 bar) [116 psi] + DIN 43650 connector with LED 24V • • • • • • • – –
E1 Electric clogging sensor (8 bar) [116 psi] + DIN 43650 connector with LED 12V • • • • • • • – –
Through drive remote filter
FR • • • • • • • = =
• : Available
– : Not available
= : Not available for HME/HMI + Cut-Off valve TE/TP
Note:
E9 feature as “Standard production” for electric clogging sensor
19
Through drive
Through drive for 2ndPump assembled by the customer
SA SAE A = Z9 - 16/32 DP
G2 GR2 L = 4
G3 GR3
TZ (1)
Tandem through drive with flange SAE B-B = 15T - 16/32 DP (Special for S5AV 032/045/050/063 pumps)
TY (2) Tandem through drive with flange SAE B - DIN 5480 W35x2x30x16x9g (Special for S5AV 050/063 pumps)
DC5A1G1_0000000 - 01/22
S6CV-P/01
L10 S6CV 075 - Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
20
Regolatore
Flushing valve
HLR HIR HIN HER HEN HE2 HEH HME HMI
XX Not request • • • • • • • • •
PR Arranged for Flushing Valve – – – – – – – • •
06 6 l/min [1.58 U.S. gpm] Orifice Diameter Ø 1.5 [0.005] – – – – – – – • •
09 10.5 l/min [2.77 U.S. gpm] Orifice Diameter Ø 2.0 [0.07] – – – – – – – • •
15 15 l/min [3.96 U.S. gpm] Orifice Diameter Ø 2.5 [0.09] – – – – – – – • •
21 20 l/min [5.28 U.S. gpm] Orifice Diameter Ø 3.0 [0.11] – – – – – – – • •
• : Available
– : Not available
21
Caratteristica pompa
XXX Not request
22
Verniciatura
XX Not request
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Manual lever control with Feed-Back S6CV 075 - Control HLR L11
The displacement of the pump is directly proportional to the angle of rotation of the lever. The feedback system feels the position of
the swashplate and works automatically to compensate for a positioning error. The diagram below shows the ralationship between
angle and displacement.
40
30
v]
3 /re
in
57
20
v [4. PS T GS GA
3 /re
cm X2
10 75
X1 V1 A
Angle (°)
0 V4
-10 V2
] R1 R2
rev
n/
3
i
4 .57 V3
-20 v[
3 /re
c m
75
-30
B
-40
-100 -80 -60 -40 -20 0 20 40 60 80 100
L2 FA FA1 GB
Vg/Vg max (%) Z1 Z2 S L1 L3 GT
ø8
[0
.3
15
40°
]
The torque necessary at the control lever is between 1 and 2.45 Nm [0.737
and 1.80 lbf·ft].
40°
60 [2,36]
Note:
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic fluid, abrasion or
residual contamination from system components). As a result, the axial piston unit can no longer supply the flow specified by the operator. Check
whether your application requires that remedial measures be taken on your machine in order to bring the driver consumer into a safe position (e.g.
immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
L12 S6CV 075 - Hydraulic proportional control with Feed-Back HIR
The pump displacement is proportional to the pilot pressure on Y1 or Y2 ports, which also affect flow direction. The feedback
system feels the position of the swashplate and works automatically to compensate for a positioning error. Piloting can be provided
by boost pressure from GS port. The piloting pressure will then have to be controlled by a joystick or by a pressure reducing valve
(not supplied).
psi bar
300 20
240 16 v] Y2 Y1
3 /re
in
4.57
180 12 v[
3 /re PS GS GA
cm
75 X2
120 8
X1 V1
A
Pressione/Pressure
60 4
V4
Pressure
bar [psi]
0 0
V2
R1 R2
-60 -4
V3
-120 -8 v]
3
n /re
7i
4.5
-180 -12 v[
3 /re
m
75c B
-240 -16
Pilot pressure = 6÷18 bar [87÷261 psi] (at ports Y1, Y2)
Start of control = 6 bar [87 psi]
End of control = 18 bar [261 psi] (Max displacement)
Note:
The tolerance on piloting pressure is ± 10% of maximum value.
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic fluid, abrasion or
residual contamination from system components). As a result, the axial piston unit can no longer supply the flow specified by the operator. Check
whether your application requires that remedial measures be taken on your machine in order to bring the driver consumer into a safe position (e.g.
immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
Y2 Y2
B B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Hydraulic proportional control without feed-back HIN L13
The pump displacement is proportional to the pilot pressure on Y1 or Y2 piloting ports, which also affect flow direction. The flow is
also influenced by the working pressure and by the rotation speed of the pump. With a given input signal (piloting pressure) the
pump can vary the displacement and the flow when working pressure or rotating speed change. Feeding pressure to the control
joystick can be provided by charge pressure from GS port. The piloting pressure must then be controlled by said joystick or by a
pressure reducing valve (not supplied). The orifice dimensions must be choosed in function of the response time required, see the
table below.
Warning:
Use of the HIN control can require a review of the motor engine and vehicle parameters to ensure that the pump is set up correctly.
We recommend that all HIN applications be reviewed by a Dana. In case, please contact our technical service.
Y2 Y1
Y2 Y1
V1: CLOSED
PS GS GA
PS GS GA
X2
X1 V1 X2
A X1 A
V4
V4
V2
R1 R2 V2
R1 R2
V3 V3
B B
L2 FA L2 FA
Z1 Z2 S L1 L3 GT FA1 GB Z1 Z2 S L1 L3 GT FA1 GB
psi bar
300 20
240 16
]
3 /rev
180 12 7 in
[4.5
3 /rev
cm
Pilot pressure = 6÷14 bar [87÷ 203 psi] (at ports Y1, Y2) 120 8
75
-60 -4
]
/rev
Note:
3
-120 -8 7 in
[4.5
The tolerance on piloting pressure is ± 10% of maximum value. 3 /rev
cm
-180 -12 75
-240 -16
-300 -20
-100 -60 -20 0 20 60 100
Y2
Y2
A
A
DC5A1G1_0000000 - 01/22
S6CV-P/01
L14 S6CV 075 - Electric proportional control with feed-back HER
The displacement of the pump is directly proportional to the input current of one of the two proportional solenoids. The feedback
system feels the position of the swashplate and works automatically to compensate for a positioning error. The input current of the
two proportional solenoids must be controlled by an external amplifier card and it is recommended to use our amplifier specific for
S6CV. Flow direction depends on which solenoid is energized. Standard solenoids are proportional at 24V d.c. max. current 1A.
(Optional solenoids 12V d.c. max. current 2A).
For emergency operation only it is however possible to control solenoids directly with 24V d.c.voltage (or 12V d.c.), by-passing the
amplifier.
mA
1200
1000 v]
3 /re
in
57
800 4.
v[
3 /re
cm
600 75 ]
3 /rev GS GA
7 in PS
[4.5
400 12V 3 /rev
cm X2
75
X1 V1
200 24V A
Current
0 V4
-200
V2
24V
R1 R2
3 /rev
]
-400 7 in 12V
[4.5 V3
3 /rev
cm
-600 75
v]
3 /re
in
-800 .57
[4
3 /re
v B
-1000 cm
75
FA
-1200 Z1 Z2 S L1 L2 L3 GT FA1 GB
-100 -80 -60 -40 -20 0 20 40 60 80 100
Solenoid 24V:
Current min. 200 mA max 600 mA
Solenoid 12V:
Current min. 400 mA max 1200 mA
Note:
The tolerance on piloting current is ± 10% of maximum value.
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic
fluid, abrasion or residual contamination from system components). As a result, the axial piston unit can no longer supply the flow
specified by the operator. Check whether your application requires that remedial measures be taken on your machine in order to
bring the driver consumer into a safe position (e.g. immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B
B
A
A
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Electric proportional control without feed-back HEN L15
The displacement of the pump is directly proportional to the input current of one of the two proportional solenoids. The flow is also
influenced by the working pressure and by the rotation speed of the pump. With a given input signal (piloting current) the pump can
vary the displacement and the flow when working pressure or rotating speed change. The input current of the two proportional sole-
noids must be controlled by an external amplifier card and it is recommended to use our amplifier specific for S6CV. Flow direction
depends on which solenoid is energized. Standard solenoids are proportional 24V d.c. max. current 1A. (Optional solenoids 12V
d.c. max. current 2A). For emergency operation only it is however possible to control solenoids directly with 24V d.c.voltage (or 12V
d.c.), by-passing the amplifier.
Warning:
Use of the HEN control can require a review of the motor engine and vehicle parameters to ensure that the pump is set up correctly.
We recommend that all HEN applications be reviewed by a Dana. In case, please contact our technical service.
mA
1400
1200 v]
3 /re
7 in
1000 4.5
v[
3 /re
c m
800
75
3 ev
]
600 12V in /r PS GS GA
[ 4.57
/rev 3
400 75 cm X2
X1 V1
24V A
200
V4
Current
0
V2
R1 R2
-200
3 ev
] 24V
in /r V3
-400 [ 4.57
/rev
3
75 cm
-600 12V
v]
3 /re B
n
-800 7i
4.5
v[
-1000 3 /re
cm L2 FA
75 Z1 Z2 S L1 L3 GT FA1 GB
-1200
-1400
-100 -80 -60 -40 -20 0 20 40 60 80 100
Solenoid 24V:
Current min. 300 mA max 650 mA
Solenoid 12V:
Current min. 600 mA max 1300 mA
Note:
The tolerance on piloting current is ± 10% of maximum value.
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
S2 S2
B B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
L16 S6CV 075 - Electric On-Off HE2
By switching on one of the solenoids the pump swivels to maximum displacement in the corresponding output flow direction.
Switching off the stated solenoid will result in swivelling back the pump to zero displacement position.
PS GS GA
X2
X1 V1 A
V4
V2
R1 R2
V3
L2 FA
Z1 Z2 S L1 L3 GT FA1 GB
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
S1 S1
S2
S2
B
B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Electric proportional control with hydraulic emergency override HEH L17
This control has the same electric proportional features of HER control, but it also has an emergency hydraulic proportional control
capability when a pilot pressure on Y1 and Y2 ports. The input current of the two proportional solenoids must be controlled by an
external amplifier card and it is recommended to use our amplifier specific for S6CV. Hydraulic operation of HEH control is meant to
be an emergency device to control displacement of the pump in case of a breakdown of the electric circuit. A pilot pressure of 22
bar [319 psi] is required to swivel the pump to max displacement in emergency operation.
S1
Y2
Y1
PS GS GA
X2
X1 V1
A
V4
V2
R1 R2
V3
Z1 Z2 S L1 L2 L3 GT FA FA1 GB
Warning:
Y1 and Y2 ports must not have any back pressure durino normal electric control operation (vented to tank).
Note:
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic fluid, abrasion or
residual contamination from system components). As a result, the axial piston unit can no longer supply the flow specified by the operator. Check
whether your application requires that remedial measures be taken on your machine in order to bring the driver consumer into a safe position (e.g.
immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B
B
A
A
DC5A1G1_0000000 - 01/22
S6CV-P/01
L18 S6CV 075 - Automotive HME-HMI
The “AUTOMOTIVE” (speed related) control, is used in hydrostatic transmissions with closed loop variable displacement pumps.
This kind of controls allows to:
• Control of the vehicle translation speed;
• Limit the amount of Torque required from the Engine;
• Inching of the vehicle speed. The control of the Inching valve can be done with an hydraulic signal (Minimum 12 bar [174 psi]
is required to swivel the pump to null displacement) or with a lever.
• Possibility to control the direction of flow electrically (HME) and hydraulically (HMI).
To allows an oil cooling action, when operating at high speed and power, it is possible to mount a flushing valve.
Y1 HMI Y2 Y1 HMI Y2
HME HME
St Pi UNF St Pi UNF
Pi Gas Pi Gas
VC VS In VC VS In
VT T1 VT T1
T GS T GS
PS GA PS GA
X1 X1
X2 V1 X2 V1
A A
V4 V4
V2 V2
R1 R2 R1 R2
V3 V3
B B
L2 FA L2 FA
Z1 Z2 S L1 L3 GT FA1 GB Z1 Z2 S L1 L3 GT FA1 GB
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
HMI (CCW)
HMI HME
HME(CCW) HMI (CW) HME
HME(CW)
Y1 S1 Y1 S1
Y2 S2 Y2 S2
B
B B
B
A A
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Pressure compensator valve and electric Cut-off valve PC - TE L19
Note:
The pressure compensator valve is standard on HD1 pump and it can be combined with TE (EP) valve.
Valvola EP Valve
EP Valve
Detail C
S1
PS GS GA
X2
X1 V1 A
V4
V2
R1 R2
V3
The electric cut-off valve, directly flangeable on S6CV pump housing, swivels back to zero the pump flow when power supply to the
ON/OFF solenoid is cut-off. This valve has been designed for applications subject to safety rules, which required stopping of the
machine in case of no electric signal. Feed voltage is 24V d.c. (optional 12V d.c.).
Valvola EP Valve
EP Valve
S1
PS GS GA
X2 Spline
X1 V1 A
V4
V2
R1 R2
V3
L2
Z1 Z2 S L1 L3 GT FA FA1 GB
DC5A1G1_0000000 - 01/22
S6CV-P/01
L20 S6CV 075 - Pressure filter
18 Filter
In order to guarantee an optimum fluid contamination level in the closed loop the S6CV can be equipped with a filter positioned on
the delivery outlet of the charge pump. Only the flow necessary to reintegrate the lost oil due to leakage will pass through the filter, all
the excess flow is not filtered and discharged through the pump drain line. In this way a longer life of the filter is achieved. The filter
contains a composite fibre filtering element, with capacity of 12 micron absolute. The system uses sensors of clogging differential
pressure of 8 bar [116 psi]) in optical and electrical (Connector DIN43650/ISO4400) version.
It is available a conversion cable from DIN43650/ISO4400 to Deutsch DT04 connector. The filter is without by-pass.
It is available a Remote Filter version for filtering in filter pressure not mounted on the pump.
It’s possible to combine the filter with both cut-off valves.
1 N.A. 3
2 N.C.
S1
S1
PS GS GA PS GS GA
X2 X2
X1 V1 X1 V1
A A
V4 V4
V2 V2
R1 R2 R1 R2
V3 V3
B B
Z1 Z2 S L1 L2 L3 GT FA FA1 GB Z1 Z2 S L1 L2 L3 GT FA FA1 GB
Non fornito
Not supplied
Not
supplied
B
B
L1 L2 L3 GT FA FA1 GB Z1 Z2 L1 L2 L3 GT FA FA1 GB
Z1 Z2 S S
21 Pump feature
The By-pass valve allows, if necessary, to connect the pressure port line A and B.
To open the valve unlock the locking nut and turn the screw 6 turns counter-clockwise
PS T GS GA
X1
X2 V1
A BY-PASS
V4
V2
R1 R2
V3
Z2 Z1 S L1 L2 L3 GT FA FA1 GB
DC5A1G1_0000000 - 01/22
S6CV-P/01
L22 S6CV 075 - Pump and controls dimensions
10 Control
Regolatore HLR Control
HLR
159.3 [6.27]
36.1 [1.42]
222.7 [8.77]
34 [1.34]
231.1 [9.10]
288.1 [11.34]
L3
GA
GS
FA2
Displacement
Regolazione setting
della cilindrata Displacementdella
Regolazione setting
cilindrata
Displacement setting Displacement setting
71.9 [2.83] 37.8 [1.49]
162.6 [6.40]
ø127-0.05 [5.00 -0.002]
0.000
27.8 [1.09]
15 [0.59]
21.7 [0.85]
PS
35.8 [1.41]
0
169.8 [6.69]
170.8 [6.72]
146.2 [5.76]
B
81.6 [3.21]
81.6 [3.21]
114.6 [4.51]
149 [5.87]
18 [0.71]
83.5 [3.29]
95.3 [3.75]
24.5 [0.96]
33.8 [1.33]
27.8 [1.09]
114.6 [4.51]
15 [0.59]
A 122.6 [4.83]
122.3 [4.81] 180 [7.09]
L1 143.1 [5.63]
212 [8.35] L2
8]
211.6 [8.33]
0.9
M12 (M)
5[
FA1
GB
324.6 [12.78]
20 [0.79]
288.1 [11.34]
222.7 [8.77]
231.6 [9.12]
36.1 [1.42]
10.5 [0.41]
Z2 S Z1
64.5 [2.54] 64.5 [2.54]
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Pump and controls dimensions L23
10 Control
HIR
Regolatore HIR Control
142.6 [5.61]
56.5 [2.22] 56.5 [2.22]
V1
158.8 [6.25]
128.1 [5.04]
128.1 [5.04]
Y1 Y2
Y1, Y2: Control piloting pressure ports -1/4” G (BSPP) (ISO) - 7/16” - 20 UNF 2B (SAE)
V1: Adjustable throttle valve
V1
137.6 [5.41]
124.1 [4.89]
124.1 [4.89]
Y1 Y2
Y1, Y2: Control piloting pressure ports -1/4” G (BSPP) (ISO) - 7/16” - 20 UNF 2B (SAE)
V1: Adjustable throttle valve
HIN
Regolatore HIN valve
with Cut-Off con valvole di taglio
HIN Control with cut-off valves
125 [4.92]
Spline
Y1, Y2: Control piloting pressure ports -1/4” G (BSPP) (ISO) - 7/16” - 20 UNF 2B (SAE)
V1: Adjustable throttle valve
DC5A1G1_0000000 - 01/22
S6CV-P/01
L24 S6CV 075 - Pump and controls dimensions
10 Control
HER
Regolatore HER Control
V1
1616.4 [6.55]
161.97 [6.38]
V1: Adjustable throttle valve
HEN
Regolatore HEN Control
V1
148.1 [5.83]
148.1 [5.83]
HE2
Connector DIN 43650 (ISO 4400)
188.3 [7.41]
128.5 [5.06]
185.5 [7.30]
174.4 [6.87]
129 [5.08]
129 [5.08]
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Pump and controls dimensions L25
10 Control
HEH
Regolatore HEH Control
V1
156.1 [6.15]
156.1 [6.15]
Y1 Y2
Y1, Y2: Control piloting pressure ports -1/8” G (BSPP) (ISO) - 5/16” - 24 UNF (SAE)
V1: Adjustable throttle valve
DC5A1G1_0000000 - 01/22
S6CV-P/01
L26 S6CV 075 - Pump and controls dimensions
10 Control
Automotive HME con Inching idraulico (IH)
Automotive HME with hydraulic inching (IH)
Automotive HME with hydraulic Inching (IH)
98.5 [3.88]
In
299.1 [11.78]
320.1 [12.6]
25 [0.98]
Pi UNF T
44 [1.73]
115 [4.53]
Pi Gas
106 [4.17]
13 [0.51]
19.5 [0.77]
T1
103.5 [4.07] Without flushing valve 161.6 [6.36]
Without flushing valve
Thermostatic valve
With flushing valve
Flushing valve
mm [inc
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Pump and controls dimensions L27
Control
Automotive10HMI con Inching idraulico (IH)
Automotive HMI with hydraulic inching (IH)
Automotive HMI with hydraulic Inching (IH)
98.5 [3.88]
In
320.1 [12.6]
86.4 [3.4]
116.5 [3.59]
99.5 [3.92]
122.8 [4.83]
94.5 [3.72]
Y1 Y2
159.1 [6.27]
25 [0.98]
Pi UNF T
44 [1.73]
115 [4.53]
Pi Gas
106 [4.17]
13 [0.51]
19.5 [0.77]
T1
Without flushing valve
Flushing valve
mm [inch]
Y1-Y2: Control piloting pressure ports - 1/4” G (BSPP) (ISO) - 7/16” - 20 UNF with Nipple (SAE
DC5A1G1_0000000 - 01/22
S6CV-P/01
L28 S6CV 075 - Shafts dimensions
10 Shaft end
Splined Splined
AC shaft 13 shaft
SAE 1-3/8” 21T 16/32 - FLAT ROOT CLASS 5 SAE 1-1/4” 14T 12/24 DP - FLAT ROOT CLASS 5
ANSI B92.1a - 1976 ANSI B92.1a - 1976
55.9 [2.2]
55.9 [2.2]
48 [1.89] 48 [1.89]
3/8-16 UNC-2B
39.3 [1.55]
40.2 [1.58]
22 [0.87] 22 [0.87]
M10
ø34 [1.338]
ø31.2 [1.228]
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Pump and accessories dimensions L29
Optical
84.2 [3.32] Ottico/Optical
123 [4.84]
252.6 [9.94]
85.3 [3.36]
60 [2.36]
22
Elettrico/Electric
[0.
8 7]
Electric
42.1 [1.66]
216.1 [8.51]
105.1 [4.14]
Ottico/Optical
84.2 [3.32] Optical
72 [2.83]
85.3 [3.36]
22
Elettrico/Electric
[0.
87
]
Electric
160 [6.3]
133.5 [5.26]
22
[0.
95.1 [3.74]
87
]
89.9 [3.54]
101.8 [4.01]
DC5A1G1_0000000 - 01/22
S6CV-P/01
L30 S6CV 075 - Pump and accessories dimensions
165.3 [65.08]
154.2 [6.08]
100.55 [3.96]
81.4 [3.20] 108.5 [4.27]
Connector DIN 43650 (ISO 4400)
131.5 [5.18]
109.25 [4.30]
72 [2.83]
89.8 [3.54]
101.8 [4.00]
Filtro remoto
Remote filter
Remote filter
121.5 [4.78]
26 [1.02]
9 [0.35]
252.1 [9.93]
1/2 G (BSPP) (ISO) 103 [4.06]
7/8” - 14 UNF (SAE)
41.5 [1.63]
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Pump and accessories dimensions L31
142 [5.59]
193.1 [7.60] Valvola di taglio pressione 119.75 [4.71]
Cut-Off pressure valve
Cut-off pressure valve
148 [5.83]
11 [0.43]
153.5 [6.04]
91.5 [3.6]
10.5 [0.41]
157.75 [6.21]
193.1 [7.60] Valvola di taglio pressione
Cut-Off pressure valve
Cut-off pressure valve
120.5 [4.74]
Connector DIN 43650 (ISO 4400)
148 [5.83]
92.3 [3.63]
11 [0.43]
180 [7.09]
DC5A1G1_0000000 - 01/22
S6CV-P/01
L32 S6CV 075 - Pump and accessories dimensions
21 Pump feature
216.1 [8.51]
123 [4.84]
191.3 [7.53]
BPV By - pass
BY-PASS
120 [4.72]
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Through drives L33
S6CV 75 pump can be supplied with through drive. The through drive can driving with a second S6CV 75 or a pump of other kind.
The maximum permissible torques on drive shaft of the first pump and the maximum through drive torques are listed in the table
below.
WARNING:
The effective torque value on the shaft of first pump is given by the sum of the torques required from each pump making the system.
M1
ME
MC
Displacement
075
AC 13
Drive shaft
(Z21 16/32 DP) (Z14 12/24 DP )
DC5A1G1_0000000 - 01/22
S6CV-P/01
L34 S6CV 075 - Tandem combination dimensions
19 Throught drive
557.7 [21.96]
212.6 [8.37]
669.2 [26.35]
Configuration
075/075
Shafts AC AC
Shafts AC 13
Shafts 13 13
Warning:
The TA-TB-BT-TC-TX-TZ-TY through drives must be used in the configuration of the first pump in the following cases:
Example:
• If it is needed to purchase a Tandem pump combination with two S6CV 75 pumps and the second pump has the AC (21T - 16/32 DP) shaft, the
first pump will must have the TX through drive.
• If it is needed to purchase a single S6CV 75 pump for Tandem pump combination with a S6CV 75 second pump with 13 (14T - 12/24 DP shaft,
the pump will must have the TC through drive.
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 075 - Throught drives dimensions L35
19 Throught drive
Flangia SAE A (SA)
SAE A (SA) Flange
SA SAE A flange
326.6 [12.85]
Alla flangia/To mounting
to mounting flangeflange
Scanalato/Splined
Splined
SAE A 5/8” 9T 16/32 DP
ø82.55 [3.25]
OR 2.62x82.22 (2-152)
20 [0.79]
106 [4.17]
326.6 [12.85]
Alla flangia/To mounting
to mounting flange flange
175 [6.89]
I
ø101.6 [4.00]
N° 2 Fori/Holes
N° 2 holes M12 (ISO) OR 2.62x101.27 (2-155)
N° 2 Fori/Holes
N° 2 holes 1/2” 13 UNC-2B (SAE) 10 [0.39]
20 [0.79]
344.6 [13.56]
Alla flangia/To mounting
to mounting flangeflange
114.6 [4.51]
Scanalato/Splined
Splined
SAE C 1-1/4 14T 12/24 DP
SAE C-C 1-1/2 17T 12/24 DP
114.6 [4.51]
ø127 [5.00]
OR 3.53x126.6 (2-250)
38 [1.5]
N° 4 Fori/Holes
N° 4 holes M14 (ISO) N°N°2 2Fori/Holes
holes M16M16
(ISO)(ISO)
181 [7.13]
N° 4 Fori/Holes
N° 4 holes 1/2” 13 UNC (SAE) N°N°2 2Fori/Holes 5/8”
holes 5/8”11 11 (SAE)
UNC UNC (SAE)
DC5A1G1_0000000 - 01/22
S6CV-P/01
L36 S6CV 075 - Throught drives dimensions
19 Throught drive
G2 Flangia G2
G2 flange
G2 Flange
327.1 [12.87]
Alla flangia/To
To mounting flangemounting flange
ø36.5 [1.44]
32.5 [1.28]
OR 3.53x34.52 (2-220)
CONICITÀ
Tapered 1:81:8
TAPERED 1:8
20 [0.79]
63.5 [2.5]
deep 12
N° 4 M8 PROF.
N° 4[0.47]
M8 DEEP [0.47]
G3Flangia G3
G3 flange
G3 Flange
327.1 [12.87]
To Alla
mounting flange
flangia/To mounting flange
98.5 [3.88]
43 [1.69]
ø50.8 [2.00]
OR 2.62x50.47 (2-136)
85 [3.35]
CONICITÀ
Tapered 1:81:8
TAPERED 1:8
20 [0.79]
N° 4 M10
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Ordering code L37
The following alphanumeric codes system has been developed to identify all of the configuration options for the S6CV 128 pumps.
Use the model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering. We recommend to carefully read the catalogue
before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Control feature
Flushing valve
Through drive
Displacement
Charge pump
Pump feature
Shaft end
Painting
Version
Control
Flange
Series
Pump
Filter
S6CV P 128 60 60 ME 11 BE DX HME 24 00 25 25 AF PC 000 XX XX XX XXX 01
1
Series
S6CV Variable displacement axial piston pump for closed circuit
2
Pump
P Pump
3
Displacement
128 128 cm3/rev [7.808 in3/rev]
4
Displacement limitation side A
0+136 From 0 cm /rev to 136 cm3/rev [8.296 in3/rev]
3
5
Displacement limitation side B
0+136 From 0 cm3/rev to 136 cm3/rev [8.296 in3/rev]
DC5A1G1_0000000 - 01/22
S6CV-P/01
L38 S6CV 128 - Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
6
Version
ME ISO
SE SAE
7
Mouting flange
11 SAE-D 2/4 Bolts
8
Shaft end
BF Splined Z13 - 16/32” DP
BI Splined W45x2x30x21
BL Splined W40x2x30x18
Note:
For Tandem assembly check chapter “TANDEM COMBINATION DIMENSIONS”
9
Direction of rotation (viewed from shaft side)
DX CW
SX CCW
10
Control
HLR Manual lever with feed-back
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Ordering code L39
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
11
Control
Control features
HLR HIR HIN HER HEN HE2 NEH HME HMI
IH Hydraulic inching – – – – – – – • •
IM Inching Mechanical inching – – – – – – – – –
00 Without inching – – – – – – • •
12 (V) 12 connector DIN 43650 – – – • • • • • –
24 (V) 24 connector DIN43650 – – – • • • • • –
Voltage
D2 (V) 12 - Deutsch DT04 – – – • – • • • –
D4 (V) 24 - Deutsch DT04 – – – • – • • • –
00 mm [in] Without control orifices S • – • – – – – –
05 mm [in] Ø 0.5 [Ø 0.019] – – • – – – – – –
06 mm [in] Ø 0.6 [Ø 0.024] – • – • – – – – –
07 mm [in] Ø 0.7 [Ø 0.027] – • • • – – – – –
08 mm [in] Ø 0.8 [Ø 0.031] – S S S S – S – –
Control orifices diameter (1)
H8 mm [in] Ø 0.8 [Ø 0.031] – • – – – – – – –
09 mm [in] Ø 0.9 [Ø 0.035] – • • – – – – – –
12 mm [in] Ø 1.2 [Ø 0.047] – • – – – S – S S
15 mm [in] Ø 1.5 [Ø 0.059] – – – – – – – • •
20 mm [in] Ø 2.0 [Ø 0.0787] – – – • – – – – –
(*) Starting speed (rpm) – – – – – – – • •
(*) Maximum torque speed (rpm) – – – – – – – • •
(*) Maximum torque value (Nm) – – – – – – – • •
(*) Supply the setting value.
• : Required
– : Not required
S: standard
(1)
in case of the different response times, please you contact sales office
12
Charge pump
00 Without charge pump
23 Displacement 23.1 cm3/rev [1.41 in3/rev]
27 Displacement 27.3 cm3/rev [1.647 in3/rev] Standard
13
Pressure relief valve side A
25 250 bar [3625 psi]
35 350 bar [5075 psi]
42 420 bar [6090 psi] Standard
DC5A1G1_0000000 - 01/22
S6CV-P/01
L40 S6CV 128 - Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
14
Pressure relief valve side B
25 250 bar [3625 psi]
15
Charge pressure relief valve
AF 22 bar a 1000 rpm [319 psi at 1000 rpm] Standard
16
Control
Pressure compensator and Cut-Off
HLR HIR HIN HER HEN HE2 NEH HME HMI
XX Without pressure compensator Standard • • • • • • • • •
PC Pressure compensator • • • • • • • – –
TE Electric Cut-Off • • • • • • • – –
17
Cut-Off valves
Cut-Off valves feature
XX PC TE EP
000 Feature not necessary • – – –
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Ordering code L41
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
18
Regolatore
Predisposizioni
HLR HIR HIN HER HEN HE2 HEH HME HMI
XX Without Filter Standard • • • • • • • • •
M8 Optical clogging sensor (8 bar) [116 psi] • • • • • • • – –
E9 Electric clogging sensor (8 bar) [116 psi] • • • • • • • – –
E3 Electric clogging sensor (8 bar) [116 psi] + DIN 43650 connector • • • • • • • – –
E2 Electric clogging sensor (8 bar) [116 psi] + DIN 43650 connector with LED 24V • • • • • • • – –
E1 Electric clogging sensor (8 bar) [116 psi] + DIN 43650 connector with LED 12V • • • • • • • – –
FR Through drive remote filter • • • • • • • = =
• : Available
– : Not available
= : Not available for HME/HMI + Cut-Off valve TE/TP
Note:
E9 feature as “Standard production” for electric clogging sensor
19
Through drive
Through drive for 2ndPump assembled by the customer
XX Without through drive Standard
SA SAE A = Z9 - 16/32 DP
SB SAE B = Z13 - 16/32 DP
BB SAE B-B = Z15 - 16/32 DP
SC SAE C = Z14 - 12/24 DP
S5 SAE C = Z21 - 16/32 DP
CC SAE C-C = Z17 - 12/24 DP
SD SAE D = Z13 - 12/24 DP
G2 GR2 L = 4
G3 GR3
Through drive for 2nd pump assembled by Dana
TA Tandem through drive with flange SAE A = 9T - 16/32 DP
TB Tandem through drive with flange SAE B = 13T - 16/32 DP
TZ (1)
Tandem through drive with flange SAE B-B = 15T - 16/32 DP (Special for S5AV 032/045/050/063 pumps)
TY (2)
Tandem through drive with flange SAE B - DIN 5480 W35x2x30x16x9g (Special for S5AV 050/063 pumps)
BT Tandem through drive with flange SAE B-B = 15T - 16/32 DP
TC Tandem through drive with flange SAE C = 14T - 12/24 DP
T5 Tandem through drive with flange SAE C = 21T - 16/32 DP
CT Tandem through drive with flange SAE C = 21T - 16/32 DP
TD Tandem through drive with flange SAE D = 13T - 8/16 DP
TJ Tandem through drive with flange SAE D = 23T - 16/32 DP
(1) Tandem S6CV 75 + S5AV 032/045/050/063 with shaft Z15 16/32 DP
(2) Tandem S6CV 75 + S5AV 050/063 with shaft DIN 5480 W35x2x30x16x9g
DC5A1G1_0000000 - 01/22
S6CV-P/01
L42 S6CV 128 - Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
20
Regolatore
Flushing valve
HLR HIR HIN HER HEN HE2 HEH HME HMI
XX Not request • • • • • • • • •
PR Arranged for Flushing Valve – – – – – – – • •
06 6 l/min [1.58 U.S. gpm] Orifice Diameter Ø 1.5 [0.005] – – – – – – – • •
09 10.5 l/min [2.77 U.S. gpm] Orifice Diameter Ø 2.0 [0.07] – – – – – – – • •
15 15 l/min [3.96 U.S. gpm] Orifice Diameter Ø 2.5 [0.09] – – – – – – – • •
21 20 l/min [5.28 U.S. gpm] Orifice Diameter Ø 3.0 [0.11] – – – – – – – • •
• : Available
– : Not available
21
Pump feature
XXX Not request
22
Painting
XX Not request
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Manual lever control with Feed-Back S6CV 128 - Control HLR L43
10 Control
The displacement of the pump is directly proportional to the angle of rotation of the lever. The feedback system feels the position
of the swashplate and works automatically to compensate for a positioning error. The diagram below shows the ralationship
between angle and displacement.
40
30
v]
3 /re
20 in
81
v [7. PS GS GA
3 /re
c m X2
10 28
Angolo/Angle (°)
1 X1 V1
A
Angle (°)
0 V4
V2
v] R1 R2
-10 3 /re
n
1i V3
7.8
v[
-20 3 /re
8 cm
12
-30 B
L2 FA2 FA1 GB
-40 Z1 Z2 S L1 L3 GT
-100 -80 -60 -40 -20 0 20 40 60 80 100
60 [2,36]
40°
The torque necessary at the control lever is between 1 and 2.45 Nm [0.737
and 1.80 lbf·ft].
40°
ø8
[0.
31
5]
Note:
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic fluid, abrasion or
residual contamination from system components). As a result, the axial piston unit can no longer supply the flow specified by the operator. Check
whether your application requires that remedial measures be taken on your machine in order to bring the driver consumer into a safe position (e.g.
immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
L44 S6CV 128 - Hydraulic proportional control with Feed-Back HIR
The pump displacement is proportional to the pilot pressure on Y1 or Y2 ports, which also affect flow direction. The feedback
system feels the position of the swashplate and works automatically to compensate for a positioning error. Piloting can be provided
by boost pressure from GS port. The piloting pressure will then have to be controlled by a joystick or by a pressure reducing valve
(not supplied).
psi bar
300 20
]
240 16 rev
n/
3
1i
7.8
180 12 3 /re
v[
Y2 Y1
8 cm
12
120 8 GS GA
PS
60 4 X2
Pressure
X1 V1 A
0 0
V4
-60 -4
V2
R1 R2
-120 -8
re v]
n/
3
1i
V3
-180 -12 7.8
v[
3 /re
m
-240 -16 8c
12
B
-300 -20
-100 -60 -20 0 20 60 100
Pilot pressure = 6÷18 bar [87÷261 psi] (at ports Y1, Y2)
Start of control = 6 bar [87 psi]
End of control = 18 bar [261 psi] (Max displacement)
Note:
The tolerance on piloting pressure is ± 10% of maximum value.
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic fluid, abrasion or
residual contamination from system components). As a result, the axial piston unit can no longer supply the flow specified by the operator. Check
whether your application requires that remedial measures be taken on your machine in order to bring the driver consumer into a safe position (e.g.
immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Hydraulic proportional control without feed-back HIN L45
The pump displacement is proportional to the pilot pressure on Y1 or Y2 piloting ports, which also affect flow direction. The flow is
also influenced by the working pressure and by the rotation speed of the pump. With a given input signal (piloting pressure) the
pump can vary the displacement and the flow when working pressure or rotating speed change. Feeding pressure to the control
joystick can be provided by charge pressure from GS port. The piloting pressure must then be controlled by said joystick or by a
pressure reducing valve (not supplied). The orifice dimensions must be choosed in function of the response time required, see the
table below.
Warning:
Use of the HIN control can require a review of the motor engine and vehicle parameters to ensure that the pump is set up correctly.
We recommend that all HIN applications be reviewed by a Dana. In case, please contact our technical service.
psi bar
300 20
Y2 Y1
240 16
3 /rev
]
180 12 1 in
[7.8
3 /rev PS GS GA
cm
120 8 128
X2
X1
60 4 A
Pressure
0 0 V4
V2
-60 -4 R1 R2
]
3 /rev
-120 -8 1 in V3
[7.8
3 rev
cm/
-180 -12 128
-240 -16 B
-300 -20
-100 -60 -20 0 20 60 100 L2 FA2
Z1 Z2 S L1 L3 GT FA1 GB
Vg/Vg max (%)
Pilot pressure = 6÷14 bar [87÷ 203 psi] (at ports Y1, Y2)
Maximum Pilot pressure = 30 bar [435 psi]
Start of control = 6 bar [87 psi]
End of control = 14 bar [203 psi](Max displacement)
Note:
The tolerance on piloting pressure is ± 10% of maximum value.
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
Y1 Y1
Y2 Y2
B B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
L46 S6CV 128 - Electric proportional control with feed-back HER
The displacement of the pump is directly proportional to the input current of one of the two proportional solenoids. The feedback
system feels the position of the swashplate and works automatically to compensate for a positioning error. The input current of the
two proportional solenoids must be controlled by an external amplifier card and it is recommended to use our amplifier specific for
S6CV. Flow direction depends on which solenoid is energized. Standard solenoids are proportional at 24V d.c. max. current 1A.
(Optional solenoids 12V d.c. max. current 2A).
For emergency operation only it is however possible to control solenoids directly with 24V d.c.voltage (or 12V d.c.), by-passing the
amplifier.
mA
1200
1000 v]
3 /re
in
81
7.
800 v[
3 /re
cm
600 8
12 3 /rev
]
1 in PS GS GA
[ 7.8
400 12V 3 /rev
cm X2
128
Corrente/Current (mA)
X1 V1
200 24V A
Current
0 V4
-200 24V V2
R1 R2
3 /rev
]
-400 1 in 12V
[7.8 V3
3 /rev
cm
-600 128 v]
3 /re
in
-800 .81
[7
v B
3 /re
-1000 cm
8
12
Solenoid 24V:
Current min. 200 mA max 600 mA
Solenoid 12V:
Current min. 400 mA max 1200 mA
Note:
The tolerance on piloting current is ± 10% of maximum value.
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic
fluid, abrasion or residual contamination from system components). As a result, the axial piston unit can no longer supply the flow
specified by the operator. Check whether your application requires that remedial measures be taken on your machine in order to
bring the driver consumer into a safe position (e.g. immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Electric proportional control without feed-back HEN L47
The displacement of the pump is directly proportional to the input current of one of the two proportional solenoids. The flow is also
influenced by the working pressure and by the rotation speed of the pump. With a given input signal (piloting current) the pump can
vary the displacement and the flow when working pressure or rotating speed change. The input current of the two proportional sole-
noids must be controlled by an external amplifier card and it is recommended to use our amplifier specific for S6CV. Flow direction
depends on which solenoid is energized. Standard solenoids are proportional 24V d.c. max. current 1A. (Optional solenoids 12V
d.c. max. current 2A). For emergency operation only it is however possible to control solenoids directly with 24V d.c.voltage (or 12V
d.c.), by-passing the amplifier.
Warning:
Use of the HEN control can require a review of the motor engine and vehicle parameters to ensure that the pump is set up correctly.
We recommend that all HEN applications be reviewed by a Dana. In case, please contact our technical service.
mA
1400
1200 v]
3 /re
in
1000 7.81
v[
3 /re
m
800 8c
12
] GS GA
3 /rev PS
600 12V 1 in
[7.8 X2
/rev
3
cm X1
400 128 V1
A
Corrente/Current (mA)
24V
200 V4
Current
V2
0 R1 R2
-200 V3
]
in
3 /rev 24V
-400 [7.81
3 /rev
cm
-600 128 12V B
v]
3 /re
i n
-800
7.81 L2
v[ Z1 Z2 S L1 L3 GT FA2 FA1 GB
-1000
3 /re
m
8c
12
-1200
-1400
-100 -80 -60 -40 -20 0 20 40 60 80 100
Solenoid 24V:
Current min. 300 mA max 650 mA
Solenoid 12V:
Current min. 600 mA max 1300 mA
Note:
The tolerance on piloting current is ± 10% of maximum value.
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
L48 S6CV 128 - Electric On-Off HE2
By switching on one of the solenoids the pump swivels to maximum displacement in the corresponding output flow direction.
Switching off the stated solenoid will result in swivelling back the pump to zero displacement position.
PS GS GA
X2
X1 V1 A
V4
V2
R1 R2
V3
L2 FA2
Z1 Z2 S L1 L3 GT FA1 GB
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
S1 S1
S2
S2
B
B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Electric proportional control with hydraulic emergency override HEH L49
This control has the same electric proportional features of HER control, but it also has an emergency hydraulic proportional control
capability when a pilot pressure on Y1 and Y2 ports. The input current of the two proportional solenoids must be controlled by an
external amplifier card and it is recommended to use our amplifier specific for S6CV. Hydraulic operation of HEH control is meant to
be an emergency device to control displacement of the pump in case of a breakdown of the electric circuit. A pilot pressure of 22
bar [319 psi] is required to swivel the pump to max displacement in emergency operation.
S1
Y2 Y1
PS GS GA
X2
X1 V1 A
V4
V2
R1 R2
V3
FA2
Z1 Z2 S L1 L2 L3 GT FA1 GB
Warning:
Y1 and Y2 ports must not have any back pressure durino normal electric control operation (vented to tank).
Note:
The spring return feature in the control units is not a safety device.
The spool valve inside the control unit can get stuck in an undefined position by internal contamination (contaminated hydraulic fluid, abrasion or
residual contamination from system components). As a result, the axial piston unit can no longer supply the flow specified by the operator. Check
whether your application requires that remedial measures be taken on your machine in order to bring the driver consumer into a safe position (e.g.
immediate stop).
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
Y1 Y1
Y2 Y2
S1 S1
S2 S2
B B
A A
DC5A1G1_0000000 - 01/22
S6CV-P/01
L50 S6CV 128 - Automotive HME-HMI
The “AUTOMOTIVE” (speed related) control, is used in hydrostatic transmissions with closed loop variable displacement pumps.
This kind of controls allows to:
• Control of the vehicle translation speed;
• Limit the amount of Torque required from the Engine;
• Inching of the vehicle speed. The control of the Inching valve can be done with an hydraulic signal (Minimum 12 bar [174 psi]
is required to swivel the pump to null displacement) or with a lever.
• Possibility to control the direction of flow electrically (HME) and hydraulically (HMI).
To allows an oil cooling action, when operating at high speed and power, it is possible to mount a flushing valve.
HMI Y1 HMI Y2
Y1 Y2
HME HME
St Pi UNF St Pi UNF
Pi Gas Pi Gas
VC VS VC VS In
In
T1 VT T1
VT
T T
PS GS GA PS GS GA
X1 X1
X2 A X2 A
V4 V4
R1 R2 R1 R2
V3 V3
V2 V2
B B
L2 GT FA2 L2 FA2
Z1 Z2 S L1 L3 FA1 GB Z1 Z2 S L1 L3 GT FA1 GB
Flow direction:
Correlation between direction of rotation (shaft view) control and direction of flow.
B
B B B
A A A
A
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Pressure compensator valve and electric Cut-off valve PC - TE L51
The pressure compensator valve is meant to avoid opening of the relief valves: whenever working pressure reaches the PC valve
setting, the swashplate is swivelled back reducing flow. The valve allows to maintain a costant pressure in the circuit at the setting
value. It is advisable to fit the cut-off valve to all system where pressure peaks close to the relief valves setting value occur or in
hydraulic systems engineered to the maximum pump pressure. It is recommended to set the pressure cut-off valve at 30 bar [435
psi] lower than the high pressure relief valve setting. Setting range:100÷400 bar [1450÷5800 psi].
Note:
The pressure compensator valve is standard on HD1 pump and it can be combined with TE (EP) valve.
Valvola EP Valve
EP valve
PS GS GA
X2
X1 V1
A
V4
V2
R1 R2
V3
L2 FA2
Z1 Z2 S L1 L3 GT FA1 GB
The electric cut-off valve, directly flangeable on S6CV pump housing, swivels back to zero the pump flow when power supply to the
ON/OFF solenoid is cut-off. This valve has been designed for applications subject to safety rules, which required stopping of the
machine in case of no electric signal. Feed voltage is 24V d.c. (optional 12V d.c.).
Note :
The electric Cut-Off valve can be assembled on standard S6CV pump and it can be combined with PC (EP) valve.
Valvola EP Valve
EP valve
S1
PS GS GA
X2
X1 V1
A
V4
V2
R1 R2
V3
S L2 FA2
Z1 Z2 L1 L3 GT FA1 GB
DC5A1G1_0000000 - 01/22
S6CV-P/01
L52 S6CV 128 - Pressure filter
18 Filter
In order to guarantee an optimum fluid contamination level in the closed loop the S6CV can be equipped with a filter positioned on
the delivery outlet of the charge pump. Only the flow necessary to reintegrate the lost oil due to leakage will pass through the filter, all
the excess flow is not filtered and discharged through the pump drain line. In this way a longer life of the filter is achieved. The filter
contains a composite fibre filtering element, with capacity of 12 micron absolute. The system uses sensors of clogging differential
pressure of 8 bar [116 psi]) in optical and electrical (Connector DIN43650/ISO4400) version.
It is available a conversion cable from DIN43650/ISO4400 to Deutsch DT04 connector. The filter is without by-pass.
It is available a Remote Filter version for filtering in filter pressure not mounted on the pump.
It’s possible to combine the filter with both cut-off valves.
1 N.A. 3
2 N.C.
S1
S1
PS GS GA
PS GS GA
X2
X1 V1 X2
A X1
V1 A
V4
V4
V2
R1 R2
V2
R1 R2
V3
V3
B
B
Z1 Z2 S L1 L2 L3 GT
FA2 FA1 GB
Z1 Z2 S L1 L2 L3 FA2 FA1 GB
GT
FR Remote filter
Not
Nonsupplied
fornito
Not supplied
IN OUT
PS GS GA
X2
X1 V1 A
V4
V2
R1 R2
V3
Z1 Z2 S L1 L2 L3 GT FA2 FA1 GB
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Pump and controls dimensions L53
10 Control
184.5 [7.26]
258.3 [10.17]
260.8 [10.27]
93 [3.66] 45.5 [1.79]
325.3 [12.81] L3
26.5 [1.04]
GA
FA2
GT
37.8 [1.49]
183.3 [7.22]
21 [0.83]
V1 L2
31.8 [1.25]
PS
198.7 [7.82]
207 [8.15]
197.7 [7.78]
42 [1.65]
167.2 [6.58]
B
21 [0.83]
ø152.4 [6.00]
204.9 [8.07]
161.6 [6.36]
109.6 [4.31]
101.5 [4.00]
92.5 [3.64]
96.5 [3.80]
136.5 [5.37]
34 [1.34]
34 [1.34]
38 [1.50]
364.3 [14.34]
89 [3.50] 37.8 [1.49]
25 [0.98]
FA1 GS
GB
325.3 [12.81]
260.8 [10.27]
78.5 [3.09]
243.5 [9.59]
37.5 [1.48]
Z2
Z1
mm [inch]
S
67 [2.64] 67 [2.64]
DC5A1G1_0000000 - 01/22
S6CV-P/01
L54 S6CV 128 - Pump and controls dimensions
10 Control
HIR
Regolatore HIR Control
V1
Max 189.8 [7.47]
156 [6.14]
156 [6.14]
Y2
Y1
Y1, Y2: Control piloting pressure ports -1/4” G (BSPP) (ISO) - 7/16” - 20 UNF 2B (SAE)
V1: Adjustable throttle valve
HIN
Regolatore HIN Control
137.9 [5.429] 36.8 [1.45] 36.7 [1.44]
V1
168.5 [6.63]
152.6 [6.004]
152.5 [6.004]
Y1 Y2
Y1, Y2: Control piloting pressure ports -1/4” G (BSPP) (ISO) - 7/16” - 20 UNF 2B (SAE)
V1: Adjustable throttle valve
HER
Regolatore HER Control
V1
194.5 [7.66]
189.87 [7.48]
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Pump and controls dimensions L55
10 Control
HENHEN Control
Regolatore
V1
172.5 [6.79]
154.5 [6.083]
HE2
Regolatore HE2 Control
Connector DIN 43650 (ISO 4400)
V1
200.4 [7.889]
200.4 [7.889]
211.5 [8.33]
HEH
Regolatore HEH Control
Connector DIN 43650 (ISO 4400)
V1
184 [7.24]
Y2
Y1
Y1, Y2: Control piloting pressure ports -1/8” G (BSPP) (ISO) - 5/16” - 24 UNF (SAE)
V1: Adjustable throttle valve
DC5A1G1_0000000 - 01/22
S6CV-P/01
L56 S6CV 128 - Pump and controls dimensions
10 Control
356 [14.02]
335 [13.19]
123 [4.84]
48.8 [1.92] 48.8 [1.92] 141 [5.55]
183 [7.2]
13 [0.51]
Pi UNF
Pi Gas
1 [0.04]
118 [4.65]
7.5 [0.3]
T1
56 [2.2]
Without flushing valve
190 [7.48]
Flushing valve
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Pump and controls dimensions L57
10 Control
356 [14.02]
335 [13.19]
123 [4.84]
86.4 [3.4]
86.4 [3.4]
Y2
187.5 [7.38]
13 [0.51]
Pi UNF
Pi Gas
118 [4.65]
7.5 [0.3]
1 [0.04]
T1
56 [2.2]
Without flushing valve
190 [7.48]
Flushing valve
Y1-Y2: Control piloting pressure ports - 1/4” G (BSPP) (ISO) - 7/16” - 20 UNF with Nipple (SAE)
Pi Gas: Piloting pressure gauge port - 1/4” G (BSPP) (ISO)
Pi UNF: Piloting pressure gauge port - 7/16” - 20 UNF (SAE)
In: Piloting pressure Inching port - 1/8” G (BSPP) (ISO) - 7/16” - 20 UNF with Nipple (SAE)
T1: Drainage pressure gauge port - 1/8” G (BSPP)
T: Drainage pressure gauge port - 1/4” G (BSPP)
DC5A1G1_0000000 - 01/22
S6CV-P/01
L58 S6CV 128 - Shafts dimensions
8 Shaft end
BE Splined BF Splined
43.9 [1.73]
ø37.8 [1.488]
53.4 [2.10]
ø44.2 [1.74]
M10
M10
35 [1.38] 35 [1.38]
27T 16/32” DP - ANSI B92.1a - 1976 FLAT ROOT 23T 16/32” DP - ANSI B92.1a - 1976 FLAT ROOT
BG Splined BH Splined
59.6 [2.35]
5/8-11 UNC-2B
5/8-11 UNC-2B
ø50.6 [1.992]
ø44 [1.732]
68.6 [2.70]
36 [1.42]
36 [1.42]
81.5 [3.21]
68.5 [2.69]
88 [3.46]
75 [2.95]
15T 8/16” DP - ANSI B92.1a - 1976 FLAT ROOT 13T 8/16” DP - ANSI B92.1a - 1976 FLAT ROOT
BI Splined BL Splined
ø39.6 [1.559]
ø44.5 [1.751]
36 [1.42]
36 [1.42]
53.5 [2.11]
48.5 [1.91]
60 [2.36]
55 [2.16]
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Pump and accessories dimensions L59
151.5 [5.96]
Elettrico/Electric
22
[0.
8 7]
Electric
78 [3.07]
252 [9.92]
288 [11.34]
Ottico/Optical
93.5 [3.68]
60.5 [2.38]
88.8 [3.5]
84.6 [3.33] Ottico
22
Elettrico/Electric
[0.
87
Elettrico
]
173.5 [6.831]
FR Remote filter
DC5A1G1_0000000 - 01/22
S6CV-P/01
L60 S6CV 128 - Pump and accessories dimensions
TE
Taglio elettrico (TE-EP)
Electric Cut-Off
Cut-off electric valve (TE-EP)
170 [6.69]
229 [9.02] 137 [5.394]
79.5 [3.123]
110 [4.33]
23.5 [0.93] Connector DIN 43650 (ISO 4400)
21 Pump feature
252 [9.92]
147.5 [5.81]
191.3 [7.53]
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Through drives L61
S6CV 128 pump can be supplied with through drive. The through drive can driving with a second S6CV or a pump of other kind.
The maximum permissible torques on drive shaft of the first pump and the maximum through drive torques are listed in the table
below.
WARNING:
The effective torque value on the shaft of first pump is given by the sum of the torques required from each pump making the system.
M1
ME
MC
Displacement
128
BE BF BG BH BI BL
Drive shaft
(Z27 16/32 DP) (Z23 16/32 DP) (Z15 8/16 DP) (Z13 8/16 DP) (W45x2x30x21) (W40x2x30x18)
Nm 1900 1250 2670 1640 2190 1460
Drive shaft max torque ME
[lbf·ft] [1400] [921] [1967] [1208] [1614] [1076]
Nm 1000 1000 1000 1000 1000 1000
Through drive max torque MC
[lbf·ft] [737] [737] [737] [737] [737] [737]
DC5A1G1_0000000 - 01/22
S6CV-P/01
L62 S6CV 128 - Tandem combination dimensions
19 Through drive
662.8 [26.09]
399.2 [15.716]
Vista da X Vista da Y
View from X View from Y
242.5 [9.547] View from X View from Y
18 [0.71]
13 [0.51]
Depth[0.71]
Y
45 [1.772]
7/16-20 UNF-2B
20 [0.787]
17 [0.669]
M10 Prof. 18
1818 [0.71]
M10 Depth
12 [0.47] Prof./Depth
3/8”-16 UNC 2B Depth [0.71]
Depth
M10
Depth
3/8”-16 UNC 2B Prof.
17 [0.669]
20 [0.787]
1/4 G (BSPP)
45 [1.772]
Prof./Depth
Depth
X 399.4 [15.724]
784.6 [30.89]
Configuration
128/128
Shaft BF BF-BH
Shaft BE BF-BH
Shaft BG BF-BH
Shaft BH BF-BH
Shaft BI BF-BH
Shaft BL BF-BH
Warning:
The TA-TB-TZ-TY-BT-TC-CT-TD-TJ through drives must be used in the configuration of the first pump in the following cases:
Example:
• If it is needed to purchase a Tandem pump combination with two S6CV 128 pumps and the second pump has the BF (23T - 16/32 DP) shaft,
the first pump will must have the TJ through drive.
• If it is needed to purchase a single S6CV 128 pump for Tandem pump combination with a second pump has the BH (13T - 8/16 DP) shaft, the
pump will must have the TD through drive.
DC5A1G1_0000000 - 01/22
S6CV-P/01
S6CV 128 - Through drives dimensions L63
19 Through drive
366.3 [14.42]
Alla flangia/To
to mounting mounting flange
flange
Splined
Scanalato/Splined
ø82.55 [3.25]
SAE A 5/8” 9T 16/32 DP
OR 2.62x82.22 (2-152)
N° 22 Fori/Holes
N° fori
N° 2 holesM10 (ISO)
N° 2 N° 2 holes 3/8” 16 UNC-2B (SAE)
Fori/Holes 9.5 [0.37]
20 [0.79]
106 [4.17]
146.6 [5.77]
Scanalato/Splined
Splined
13.5 [0.53] SAE B 7/8” 13T 16/32 DP
SAE B-B 1” 15T 16/32 DP
ø101.6 [4.00]
N° 2 Fori/Holes
N° 2 holes M12 (ISO) OR 2.62x101.27 (2-155)
N° 2 Fori/Holes
N° 2 holes 1/2” 13 UNC-2B (SAE) 10 [0.39]
20 [0.79]
384.3 [15.12]
Alla flangia/To
to mounting mounting flange
flange
114.6 [4.51]
Scanalato/Splined
Splined
SAE C 1-1/4 14T 12/24 DP
SAE C 1-3/8 21T 16/32 DP
SAE C-C 1-1/2 17T 12/24 DP
ø127 [5.00]
114.6 [4.51]
OR 3.53x126.6 (2-250)
38 [1.5]
N° 4 Fori/Holes
N° 4 holes M14 (ISO) N° 2 holes
Fori/Holes M16 (ISO)
N° 4 Fori/Holes
N° 4 holes1/2” 13 UNC (SAE) N° 2 holes
N° Fori/Holes 5/8” 11 UNC (SAE)
181 [7.13]
DC5A1G1_0000000 - 01/22
S6CV-P/01
L64 S6CV 128 - Through drives dimensions
19 Through drive
langia SAE D
AE D (SD)SD
Flange SAE D flange
419.4 [16.51]
Alla flangia/Toflange
to mounting mounting flange
161.6 [6.36]
Scanalato/Splined
Splined
SAE D 1-3/4 13T 8/16 DP
8.5 [0.34]
ø152.4 [6.00]
161.6 [6.36]
OR 3.53x151.99 (2-258)
73.1 [2.88]
N° 4 Fori/Holes
N° 4 holes M20 (ISO) 228.6 [9.00]
N°N°
2 2Fori/Holes
holes M20M20 (ISO)
(ISO)
N° 4 Fori/Holes
N° 4 holes 3/4” 10 UNC 2B (SAE) 270 [10.63]
N°N°
2 2Fori/Holes
holes 3/4”3/4” 10 UNC
10 UNC 2B (SAE)
2B (SAE)
Flangia G2
G2
G2 Flange G2 flange
366.3 [14.42]
Alla flangia/To
to mounting mounting flange
flange
71.5 [2.81]
4 [0.157]
32.5 [1.28]
ø36.5 [1.44]
OR 3.53x34.52 (2-220)
CONICITÀ 1:8
Tapered 1:8
20 [0.79] TAPERED 1:8
63.5 [2.5]
N° 4 M8 PROF. 12[0.47]
depth.12
N° 4 M8 DEEP [0.47]
angia G3
3 FlangeG3 G3 flange
366.3 [14.42]
Alla flangia/To
to mounting mounting flange
flange
98.5 [3.88]
43 [1.69]
ø50.8 [2.00]
OR 2.62x50.47 (2-136)
85 [3.35]
CONICITÀ
Tapered 1:8 1:8
20 [0.79] TAPERED 1:8
N° 4 M10
N° 4 M10
DC5A1G1_0000000 - 01/22
S6CV-P/01
DC5A1G1_0000000 - 01/22
DC5A1G1_0000000 - 01/22
SH7V - Variable displacement axial piston motors for open and closed circuit M1
Index
SH7V 075 80.58 [4.91] 322 [85] 430 [6235] 480 [6960]
SH7V 108 112.5 [6.86] 400 [105.6] 430 [6235] 480 [6960]
SH7V 160 160.8 [9.81] 500 [132] 430 [6235] 480 [6960]
SH7V 200 216 [13.176] 626 [165.37] 430 [6235] 480 [6960]
SH7V series are a family of variable displacement motors, bent axis piston design for operation in both open and closed circuit.
The proven design incorporating the lens shape valve plate, the high quality components and manufacturing techniques
make able the SH7V series motors to provide up to 430 bar [6235 psi] continuous and 480 bar [6960 psi] peak performance.
Fully laboratory tested and field proven, these motors provide maximum efficiency and long life even at very bad filtering conditions.
Heavy duty bearings permit high radial and axial loads. Versatile design includes a variety of control and shaft ends that will adapt
the SH7V series motors to any application both industrial and mobile.
DC5A1G1_0000000 - 01/22
SH7V-M/01
M2 General information - Features
Simbology:
N/bar l/min
C [lbf/psi]
Load qmax [U.S. gpm]
Maximum flow
N l/min
Fax max [lbf]
Axial pushing load qd [U.S. gpm]
External drain flow
N Nm/bar
Fax max [lbf]
Axial pulling load Tk [lbf.ft/psi]
Torque costant
N Nm
Fq [lbf]
Radial load Tnom [lbf.ft]
Maximum torque at pressure cont.
N Nm
Fq max [lbf]
Maximum permissible radial load Tmax [lbf.ft]
Maximum torque at pressure peak
kg·m2 cm3/rev
J [lbf·ft2]
Moment of inertia Vg [in3/rev]
Displacement
kg kW
m [lbs]
Weight Pmax [hp]
Maximum power at pnom
Hydraulic fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed.
Viscosities less then 10 cSt are not allowed. A viscosity range of 10÷15 cSt is allowed for extreme operating conditions and for short
periods only. For further information see at Fluids and filtering section.
Temperature ranges:
The operating temperature of the oil must be within -25ºC ÷ 115ºC [-13ºF ÷ 239ºF]. The running of the unit with oil temperature higher
than 115ºC [239°F] or lower than -25ºC [-13°F] is not allowed. For further information see at Fluids and filtering section.
Filtering:
A correct filtering helps to extend the service life of axial piston units. In order to ensure a correct functioning of the unit, the max.
permissible contamination class is 21/19/16 according to ISO 4406:1999. For further details see at Fluids and filtration section.
Operating pressure:
The maximum permissible pressure on pressure ports is 430 bar [6235 psi] continuous and 480 bar [6960 psi] peak. It two motors
are connected in series, total pressure has to be limited to following values: P1+P2 700 bar max. [10150 psi max].
P1 P2 P3
DC5A1G1_0000000 - 01/22
SH7V-M/01
General information - Features M3
Seals:
Seals used on standard SH7V series axial piston motors are of FKM seals (Fluoroelastomer - Viton®). In case of use of use special
fluids, contact Dana.
Port plates:
The SH7V motor port plate has inlet and outlet ports, both lateral (LM-LS cover) and frontal (FM-FS cover). Unused ports are plugged
with blind flanges. The kind of ports to be used must be specified when ordering.
Flushing valve:
The motors can be equipped with built in flushing valve for closed circuit operation.
Installation:
SH7V series motors can be installed in every position or direction. These axial piston units have separate ports and drain chambers
and so must be always drained. Installation of the unit with shaft in vertical position and above the tank involves some limitations.
For further details see at General installation guidelines.
DC5A1G1_0000000 - 01/22
SH7V-M/01
M4 Technical data
Size
55 75 108 160 200
cm3/rev 61 80.58 112.5 160.8 216
Max. Displacement Vg [in3/rev] [3.72] [4.91] [6.86] [9.81] [13.176]
cm3/rev 30 40 56 80 108
Min. Displacement Vg min [in3/rev] [1.83] [2.44] [3.416] [4.88] [6.59]
cm3/rev 12.2 16 22 32.2 43
Displacement minimum possible Vg min [in3/rev] [0.74] [0.97] [1.34] 1.96] [2.62]
cm3/rev 0 0 0 0 0
Displacement Optional Vg o [in3/rev] [0] [0] [0] [0] [0]
bar 430 430 430 430 430
Max. Press. cont. pnom [psi] [6235] [6235] [6235] [6235] [6235]
bar 480 480 480 480 480
Max. Press. peak pmax [psi] [6960] [6960] [6960] [6960] [6960]
l/min 271 322 400 500 626
Max. flow qmax [U.S.gpm] [71.5] [85] [105.6] [132] [165.37]
Max. speed at Vgmax and qmax n0 max rpm 4450 4000 3550 3100 2900
Max. speed at Vg<Vgmax(2) n0 max lim rpm 7000 6150 5600 5000 4600
Max. speed at Vg0 n0 max lim rpm 8350 7350 6300 5500 5100
(Theorical values, without considering ηhm and ηv approximate values). Peak operations must not exceed 1% of every minute. A simultaneous maxi-
mum pressure and maximum speed not recommended.
Notes:
(1) Maximum and minimum displacement can be changed with continuity. When ordering state Vgmax and Vgmin required.
(2) Determination of admissible speed nmax value can be increased by reducing motor maximum displacement. To determine the relationship
beetwen Vgmax and nmax use the right side chart. Motor maximum admissible speed is nmax lim.
(3) Approximate values.
(4) Maximum value at 250 bar [3625 psi] with mineral oil at 45ºC [113°F] and 35 cSt of viscosity.
Permessible
Velocità speed speed
ammissibile/Permessible
1.0
(Vg / Vgmax)
0.8
Cilindrata/Displacement
0.6
(Vg/Vg max)
Displscement
0.4
0.2
0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
Velocità/Speed
Speed(n/n(n/n
max)max)
DC5A1G1_0000000 - 01/22
SH7V-M/01
Ordering code M5
The following alphanumeric codes system has been developed to identify all of the configuration options for the SH11C motors.
Use the model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering.
We advise to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Flanged valves
Flushing valve
Displacement
displacement
displacement
Mount flange
specification
Serie feature
Port cover
Maximum
Shaft end
limitation
limitation
Minimum
Painting
features
Control
Control
Series
Motor
Valve
Seal
SH7V M 055 61÷30 12÷42 OC S20 FM V RPE 000 XXXX 000 PR XX XX
1
Series
SH7V Variable displacement axial piston motor for open and closed circuit
2
Motore
M Motor
3
Displacement
055 55 cm3/rev [3.355 in3/rev]
4
Displacement
Maximum displacement limitation
055 075 108 160 200
From 61 cm /rev [3.721 in /rev]
3 3
Standard
61÷30
to 30 cm3/rev [1.830 in3/rev] 30 cm3/rev [1.830 in3/rev] • – – – –
DC5A1G1_0000000 - 01/22
SH7V-M/01
M6 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
5
Displacement
Minimum displacement limitation
055 075 108 160 200
0 0 cm3/rev • • • • •
From 12 cm /rev [0.732 in /rev]
3 3
Standard
12÷42
to 42 cm3/rev [2.562 in3/rev] 30 cm3/rev [1.830 in3/rev] • – – – –
6
Displacement
Mount flange
055 075 108 160 200
OC ISO 4 Bolts Ø 125 mm [Ø 4.921 in] • – – – –
OD ISO 4 Bolts Ø 140 mm [Ø 5.511 in] – • – – –
OE ISO 4 Bolts Ø 160 mm [Ø 6.299 in] – – • – –
OF ISO 4 Bolts Ø 180 mm [Ø 7.086 in] – – – • –
OG ISO 4 Bolts Ø 200 mm [Ø 7.87 in] – – – – •
05 SAE-C 4 Bolts • • – – –
08 SAE-D 4 Bolts – – • • –
10 SAE-E 4 Bolts – – – – •
• Available
– Not available
DC5A1G1_0000000 - 01/22
SH7V-M/01
Ordering code M7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
7
Displacement
Shaft end
055 075 108 160 200
• Available
– Not available
1) Special on request
8
Displacement
055 075 108 160 200
Port cover
Mount flange
OC 05 OD 05 OE 08 OF 08 OG 10
• Available
– Not available
Warning
Referred ports are the ones on the portplate and on the controls
DC5A1G1_0000000 - 01/22
SH7V-M/01
M8 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
9
Seal
V FKM
10
Control
2EE Electric two positions control with pressure override
DC5A1G1_0000000 - 01/22
SH7V-M/01
Ordering code M9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
11
Control
Valve Feature
RPE ROE 2EE 2EN 2IE 2IN REE RED (1) REN RID (1) RIE RIN RPI ROI ROS RPS
00 None – – – – – – – – – – – – – – – –
100÷400 bar
[1430÷5802 psi] • – • – • – • • – • • – • – – –
Pressure
(*)
Setting (*)
100÷350 bar
[1430÷5076 psi]
– • – – – – – – – – – – – • • •
Start of control, 5-10-15-20 bar
(*)
Setting range (*) [72-145-218-290 psi]
– – – – – – – – – • • • – – – –
Δp Displacement 25 bar
(*)
change [363 psi]
– – – – – – – – – • • • – – – –
12 - Connector
12
DIN43650
– – • • – – • • • – – – – – • •
24 - Connector
24
DIN43650
– – • • – – • • • – – – – – • •
D2 12 - Deutsch DT04 – – • • – – • – • – – – – – • •
Voltage
D4 24 - Deutsch DT04 – – • • – – • – • – – – – – • •
12 V - ATEX T6
A2
(Solo 55 2EN)
– – – • – – – – • – – – – – – –
24 V - ATEX T6
A4
(Solo 55 2EN)
– – – • – – – – • – – – – – – –
With
04 Ø 0.4 mm [Ø 0.015 in] • – • • • • – – – – – – – – – –
Control Orifice
With
05 Control orifice (**) Ø 0.5 mm [Ø 0.0196 in] – • – – – – • • • • • • • • • •
Control Orifice
With
07 Ø 0.7 mm [Ø 0.027 in] • • • • • • • • • • • • • • • •
Control Orifice
• Available
– Not available
(*) Supply the setting value
(**) 0.4 mm [Ø 0.015 in] (standard) nozzle, provides a smooth control response (max-to-min and min-to-max), while
Ø 0.5-0.7 mm [Ø 0.0196-0.027 in] (optional) nozzle, provides a faster reaction.
Warning:
The values showed are only valid in maximum and minimum displacement conditions of the respective displacement. For
different values, verify the possibility with the control diagrams present on the catalogue.
DC5A1G1_0000000 - 01/22
SH7V-M/01
M10 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
12
Displacement
Valve
055 075 108 160 200
XXXX None • • • • •
VCD1 VCD/1 Pilot assisted overcentre valve LM LM LM LM LM
• Available
– Not available
The valves are available with ISO port cover only, please contact Technical department for SAE version
The LM - FM digit means that the valve is only available with LM - FM port cover.
13
Valve
Flanged valves features
XXXX VCD1 VCD2 VCR2 VCR4
000 Feature not necessary • – – – –
002 Not Set 0÷350 bar [0 to 5075 psi] [Piloting ratio 2.9:1] - Control of rotation CW – • – – –
006 Not Set 0÷350 bar [0 to 5075 psi] [Piloting ratio 2.9:1] - Control of rotation CCW – • – – –
003 Not Set 250÷500 bar [3625 to 7250 psi] [Piloting ratio 13:1] - Control of rotation CW – – • – –
007 Not Set 250÷500 bar [3625 to 7250 psi] [Piloting ratio 13:1] - Control of rotation CCW – – • – –
010 Not Set - Aluminum 60÷350 bar [870 to 5075 psi] [Piloting ratio 6.2:1] – – – • –
013 Not Set 140÷350 bar [2030 to 5075 psi] [Piloting ratio 4.5:1] – – – – •
• Available
– Not available
Please contact Technical department for valve which require specific setting.
For the feature see catalogue valves.
14
Flushing valve
PR Arranged for Flushing Valve
DC5A1G1_0000000 - 01/22
SH7V-M/01
Ordering code M11
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
15
Displacement
Serie feature
055 075 108 160 200
XX None • • • • •
TS Prepared for tachometer sensor • • • • •
TW Tachometer + sensor 2-channel-Hall effect PNP - 5V • • • • •
TZ Tachometer + sensor 2-channel-Hall effect • • • • •
• Available
– Not available
16
Painting
XX Not Required
01 Black Painted RAL 9005
02 Blue Painted RAL 5015
DC5A1G1_0000000 - 01/22
SH7V-M/01
M12 Hydraulic two positions control with pressure override 2EE
The 2EE control version with the pressure override allows the motor to swivel to Vgmax when the pressure setting is reached. Same
as ‘2EN’ control, when solenoid valve is switched off the motor is at Vgmax. The motor displacement is adjusted to Vgmin when the
solenoid valve is switched on and if the operating pressure rises beyond the pressure setting, the pressure limiting device overrides
the electric two positions control and the motor swivels out to Vgmax. Swivel range is from Vgmax to Vgmin (displacement setting 1 per
our ordering code).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size:
Dimensioni: 055-075-108-160 Size:200
Dimensioni:
055-075-108-160
Size: 055-075-108-160 Size: 200200
B S1 F1 S1
B
B Y1
B Y1
Vg min
Vgmax
A Vg max
A Vgmin
A S2 A S2
DC5A1G1_0000000 - 01/22
SH7V-M/01
Hydraulic two positions control 2EN M13
The electric two positions control allows the displacement of the motor to be set to Vgmax or Vgmin by switching an ON/OFF solenoid
valve. The feed back spring is missing so Vgmax or Vgmin only can be set. 12V DC and 24V DC ON/OFF solenoid are available.
The swivel range is 1 (from Vgmax to Vgmin) or 2 (swivel range from Vgmin to Vgmax).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
F1
B S1 X2 B S1
B Y1
B Y1
Vg min
Vgmax
A Vg max
A
Vgmin
A S2 A S2
DC5A1G1_0000000 - 01/22
SH7V-M/01
M14 Hydraulic two positions control with pressure override 2IE
The 2IE control version with the pressure override allows the motor to swivel to Vgmax when the pressure setting is reached. Same as
2IN control, the motor displacement is adjusted to Vgmin when the pilot pressure applied at port X2. Minimum required pilot pressure
= 10 bar [145 psi] and maximum permissible pressure at port X2=100 bar [1450 psi]. If the operating pressure rises beyond the
pressure setting, the pressure limiting device the motor swivels out to Vgmax. Swivel range is from Vgmax to Vgmin (displacement setting
1 per our ordering code).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size: Size:
Dimensioni: 055-075-108-160
055-075-108-160 200 200
Dimensioni:
Size: 055-075-108-160 Size: 200
F1 X2
X2 B
B S1
S1
B Y1
B Y1
Vg min
Vgmax
A Vg max A
Vgmin
S2 A S2
A
DC5A1G1_0000000 - 01/22
SH7V-M/01
Hydraulic two positions control 2IN M15
The hydraulic two positions control allows the displacement of the motor to be set to Vgmax or Vgmin by applying or not a pilot pressure
at port X2. The feed back spring is missing so Vgmax or Vgmin only can be set. Minimum required pilot pressure = 10 bar [145 psi]
and maximum permissible pressure at port X2=100 bar [1450 psi]. The swivel range is 1 (from Vgmax to Vgmin) or 2 (swivel range from
Vgmin to Vgmax).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
isDimensioni:
not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be Dimensioni:
055-075-108-160 applied at port
200Y1.
Size: 055-075-108-160 Size: 200
Size: Size:
055-075-108-160 200
F1 X2
S1 X2
B B
S1
B Y1
B Y1
Vg min
Vgmax
A Vg max A
Vgmin
A S2
A S2
DC5A1G1_0000000 - 01/22
SH7V-M/01
M16 Electric proportional control with pressure override REE
The REE control version with the pressure override allows the motor to swivel to Vgmax when the pressure setting is reached. Same as
REN control, when solenoid valve is switched off the motor is at Vgmax. The proportional solenoid valve is available in 12V DC and
24V DC version and with connector DIN 43650 o DEUTSCH. The motor displacement is adjusted to Vgmin when the solenoid valve is
switched on and if the operating pressure rises beyond the pressure setting, the pressure limiting device overrides the electric two
positions control and the motor swivels out to Vgmax. Swivel range is from Vgmax to Vgmin (displacement setting 1 per our ordering
code).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
B B F1
K1 S1
MB Y1
B Y1
Vg min
Vgmax
MA Vg max X1
A Vgmin
A S2
A S1 S2
DC5A1G1_0000000 - 01/22
SH7V-M/01
Electric proportional control with double step pressure override RED M17
The RED control version with the pressure override allows the motor to swivel to Vgmax when the pressure setting is reached. Same
as REN control, when solenoid valve is switched off the motor is at Vgmax. The proportional solenoid valve is available in 12V DC and
24V DC version and with connector DIN 43650 o DEUTSCH. The motor displacement is adjusted to Vgmin when the solenoid valve is
switched on and if the operating pressure rises beyond the pressure setting, the pressure limiting device overrides the electric two
positions control and the motor swivels out to Vgmax. Swivel range is from Vgmax to Vgmin (displacement setting 1 per our ordering code).
Applying a pressure to port X3, the setting of PE control can be overridden by a different value of pressure.
Setting range from 16 bar [232 psi] to 64 bar [928 psi] around.
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size: Size:
Dimensioni: 055-075-108-160 Dimensioni: 200
055-075-108-160 200
Size: 055-075-108-160 Size: 200
B F1 F3 F1
B S1
MB Y1
B Y1
X3
Vg min
MA Vg max X1 Vgmax
A Vgmin
A S1 S2 A S2
X3
DC5A1G1_0000000 - 01/22
SH7V-M/01
M18 Electric proportional control REN
The electrical proportional control allows stepless and programmable adjustment of the motor displacement proportionally to the
current strength supplied to a proportional solenoid valve available in 12V DC and 24V DC version and with connector DIN 43650 o
DEUTSCH. The proportional solenoid valve applies a force on the spool proportional to the current strength and the motor swivels
until a force balance is restored by a feed-back spring. To control the proportional solenoid valve a 24V DC (12V DC) supply is
required. Current range between 200 (400) and 600 (1200) mA approx. (with standard setting of Max and Min displacement). Max
permissible current = 800 (1600) mA. Usually the swivel range is from Vgmax to Vgmin (displacement setting type 1 as per our ordering
code) so that increasing the current strength the motor swivels towards Vgmin, however displacement setting type 2 (swivels range
from Vgmin to Vgmax) is also available. The electronic devices are available to control the solenoid (they must be ordered separately).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size:
055-075-108-160
-075-108-160 I REN 12V (2) I REN 12V (1)
8-160 B mA
S1 REN 12V (2) mA REN 12V (1)
B Y1 1600 1600
1400 1400
1200 1200
Current
1000 1000
Current
12V 12V
I (mA)
I (mA)
800 800
600 600
400 400
Vg min
200 200
A Vg max
0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1
A S2 VVg/Vg
g
/V max(%)
g max
Vg/Vg max
Vg/V (%)
g max
Size:
200
I I
F1 S1 REN 24V (2) REN 24V (1)
B mA mA REN 24V (1)
REN 24V (2)
800 800
B Y1 700 700
600 600
Current
Current
500 500
24V
I (mA)
I (mA)
DC5A1G1_0000000 - 01/22
SH7V-M/01
Hydraulic proportional control with pressure override RIE M19
The RIE control version with the pressure override allows the motor to swivel to Vgmax when the pressure
setting is reached. Same as RIN control, the motor displacement is adjusted to Vgmin when the pilot pressure
applied at port X2. If the operating pressure rises beyond the pressure setting, the pressure limiting device the
motor swivels out to Vgmax. Swivel range is from Vgmax to Vgmin (displacement setting 1 per our ordering code).
Start of control, Setting range from 5 bar [72.5 psi] to 20 bar [290 psi] around. Pilot pressure range 25 bar [362.5 psi]. Max
permissible pilot pressure at port X2 = 100 bar [1450 psi].
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Dimensioni:
Size: 055-075-108-160 Dimensioni:
Size:200
Size: 055-075-108-160
055-075-108-160 Size: 200200
F1 X2
B K1 X2 B
S1
MB Y1
B Y1
Vg min
Vg max X1 Vgmax
MA
A Vgmin
S1 S2 A S2
A
DC5A1G1_0000000 - 01/22
SH7V-M/01
M20 Hydraulic proportional control with double step pressure override RID
The RID control version with the pressure override allows the motor to swivel to Vgmax when the pressure
setting is reached. Same as RIN control, the motor displacement is adjusted to Vgmin when the pilot pressure
applied at port X2. If the operating pressure rises beyond the pressure setting, the pressure limiting device the
motor swivels out to Vgmax. Swivel range is from Vgmax to Vgmin (displacement setting 1 per our ordering code).
Applying a pressure to port X3, the setting of PE control can be overridden by a different value of pressure.
Setting range from 16 bar [232 psi] to 64 bar [928 psi] around. Start of control, Setting range from 5 bar [72.5 psi] to 20 bar [290 psi]
around. Pilot pressure range 25 bar [362.5 psi]. Max permissible pilot pressure at port X2 = 100 bar [1450 psi].
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size: Size:
055-075-108-160
Dimensioni: 055-075-108-160 200
Dimensioni: 200
Size: 055-075-108-160 Size: 200
X2 B F1 X2
B F1 F3
S1
MB Y1
B Y1
X3
Vg min
Vgmax
MA Vg max X1
A Vgmin
A S2
A S1 S2 X3
DC5A1G1_0000000 - 01/22
SH7V-M/01
Hydraulic two positions control RIN M21
The hydraulic proportional control allows a stepless adjustment of the motor displacement proportionally to the pilot pressure
applied at port X2. The pilot pressure applies a force on the spool and the motor swivels until a force balance on the arm is
stored by feed back spring. Therefore the motor displacement is adjusted in direct proportion with the pilot pressure. Usually the
swivel range is from Vgmax to Vgmin (displacement setting type 1 as per our ordering code) so that increasing the pilot pressure
the motor swivels towards Vgmin, however, displacement setting type 2 (swivel range from Vgmin to Vgmax) is also available. Start of
control, Setting range from 5 bar [72.5 psi] to 20 bar [290 psi] around. Pilot pressure range 25 bar [362.5 psi]. Max permissible
pilot pressure at port X2 = 100 bar [1450 psi].
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size:
ioni: 055-075-108-160
055-075-108-160
5-075-108-160
px2
RIN (1)
psi bar RIN (1)
B S1 X2
650 45
600
Y1 550
X2
pressure
B 35
di pilotaggio
500
increase
Pressure
400
350 25
fieldfield
Campo di taratura
Vg max 0
0 0.2 0.4 0.6 0.8 1
Setting
A Vg min VVg/Vg
/Vg max (%)
Setting
g max
A S2
Size:
nsioni: 200 px2
200 RIN (2)
200 psi bar RIN (2)
B F1 X2
650 45
S1 600
Pressure X 2
550
di pilotaggio
500 35
Px2 bar [psi]
B Y1 450
400
350 25
increaseincrease
300
pressure
250
200 15
pressione
150
100
Pilot pressure
50 5 Campo di taratura
0
Pilot
0 0.2 0.4 0.6 0.8 1
field
Aumento della
field
g maxmax
Setting
A Vgmin
A S2
DC5A1G1_0000000 - 01/22
SH7V-M/01
M22 Working pressure control Control RPE
The working pressure control allows to swivel the motor displacement from Vg min to Vg max when the operating pressure rises
beyond the preset operating pressure, so that the motor is at Vg min when min torque and max speed are required and at Vg max
when max torque and min speed are required. The operating pressure applies a force on the spool which is matched by an
adjustable spring. The motor keeps the Vgmin until the operating pressure reaches the setting value (pressure setting). Once
the preset pressure rises beyond, the motor swivels from Vg min to Vg max. The swivel range is from Vg min to Vg max (displacement
setting type 2 as per our ordering code). Start of control adjustable between 100 and 400 bar [1450 and 5800 psi].
Size:
055 - 075 - 108 - 160
55-075-108-160
108-160
B S1
B Y1 psi p bar
psi bar
6500 450
6000
400
5500
4500
A Vg max 300
Pressure
Setting field
4000
3500 250
A S2
3000
200
2500
Size: 2000
150
Torque
T/Tat 400 bar [5946 psi]
Vg min
A Vg max
A S2
DC5A1G1_0000000 - 01/22
SH7V-M/01
Working pressure control with hydraulic override Control RPI M23
The hydraulic limiting device makes possible to reduce the pressure setting of RPE control by means of an
external pilot pressure applied at port X2. The RPE control pressure setting is reduced proportionally to the
pilot pressure in the ratio of 1/17 (for each pilot pressure bar, the preset operating pressure is reduced of 17
bar) [170 psi each 10 psi of pilot pressure]. Max permissible pilot pressure at port X2 = 100 bar [1450 psi].
Example: preset operating pressure of RPE control = 300 bar [4350 psi]. By applying at port X2 a pilot pressure of 10 bar [145
psi] , the pressure setting comes to 130 bar [1885 psi] (300-(10x17)=130) (4350- (145X17)=1885). Should it be required to swivel
the motor to Vgmax independently from the operating pressure, a pilot pressure of 20 bar [290 psi] should be applied at port X2.
Swivel range from Vgmin to Vgmax (assembly type 2 as per our ordering code). Start of control adjustable between 100 and 400 bar
[1450 and 5800 psi].
nsioni: 055-075-108-160
Size:
055-075-108-160
055-075-108-160
B S1 X2
B Y1
p
psi
psi bar
bar
450 [6525] 6500 450
6000
400 [5800] 400
Vg min 5500
field
Pressione/Pressure Torque bar/[psi]
4500
300 [4350] 300
taratura/Setting
Pressure
A S2 4000
field
250 [3625] 250
Campo diSetting
3500
Size:
3000
200 200 [2900] 200
imensioni: 200 2500
ize: 200 150 [2175] 150
F1 S1 2000
B
0 0
0 0.2 0.4 0.6 0.8 1 1.2
Vgmin
Coppia/TorqueTorque
(T/Tat 400 bar [5946 psi])
A Vgmax 0 0.2 T/Tat 0.6
0.4 0.8 psi]
400 bar [5946 1 1.2
A S2
DC5A1G1_0000000 - 01/22
SH7V-M/01
M24 Working pressure control with electrical override RPS
RPS control is a pressure related control which permits the changing of displacement Vg min to Vg max when working pressure
exceeds setting threshold, so that the motor works at Vg min when low torque and high speed are required and at Vg max when high
torque and low speed are required. The motor stands at Vg min till working pressure reaches setting threshold.
Δp of working pressure that allows the changing of diaplacement from minimum to maximum is around 10 bar (such as RPE
control).
This pressure related control can be overridden by an electrical signal; when solenoid is energized , the motor reaches maximum
displacement without stopping in an intermediate position. Swivel range from Vg min to Vg max (assembly type 2 as per our ordering
code).
Setting pressure range is 100-300 bar.
Size: Size:
055 - 075 - 108 - 160 200
Dimensioni: 055-075-108-160 Dimensioni: 200
Size: 055-075-108-160 Size: 200
F2 F1 Y1 B F1 S1
B
Ma
B Y1
Vg min
Vg min
X1
Mb Vg max
A Vg max
A S2
A S1 S2
DC5A1G1_0000000 - 01/22
SH7V-M/01
Working pressure control - high pressure rise ROE M25
The “ROE” control allows a larger pressure range for displacement variation in comparison to “RPE” control. The increase of
pressure range for variation from Vgmin to Vgmax allows a smoother working of the motor during displacement variation. The “ROE”
allows the displacement variation with the pressure range show in the table.
Δp Pmin Pmax
bar [psi] bar [psi] bar [psi]
Where:
• ∆p is the working pressure range that allows the displacement variation.
• Pmin is the minimum pressure at which displacement variation starting can be set.
• Pmax is the maximum pressure at which displacement variation starting can be set.
Size:
055-075-108-160
ioni: 055-075-108-160
5-075-108-160 p
B S1 psi bar
psi bar
MB Y1
450 [6525] 6500 450
6000
400 [5800] 400
5500
bar [1450psi]
field field
350 [5075] 5000 350
di taratura/Setting
4500
300 [4350] 300
Vg min
∆p 1450 psi
4000
100 bar
Pressure
Campo Setting
∆p 100
250 [3625] 250
3500
MA Vg max
∆p
200 [2900]
3000
200
A S2 2500
150 [2175] 150
2000
200
ensioni: 200 50 [725]
1000
50
B F1 S1 500
: 200
0 0
0 0.2 0.4 0.6 0.8 1 1.2
B Y1
Torque
Coppia/Torque (T/Tat 350 bar [5075 psi])
T/Tat 400 bar [5946 psi]
0 0.2 0.4 0.6 0.8 1 1.2
Vgmin
Warning:
A Vgmax
in case of displacement limitation, the control shall vary
of a reduced ∆p with respect to its standard one.
A S2
Please contact Dana for more info.
DC5A1G1_0000000 - 01/22
SH7V-M/01
M26 Working pressure control Δp 100 bar with hydraulic override ROI
The hydraulic limiting device makes possible to reduce the pressure setting of ROE control by means of an external pilot
pressure applied at port X2. The ROE control pressure setting is reduced proportionally to the pilot pressure in the ratio of 1/17 (for
each pilot pressure bar, the preset operating pressure is reduced of 17 bar) [170 psi each 10 psi of pilot pressure]. Max permissible
pilot pressure at port X2 = 100 bar [1450 psi].
Example: preset operating pressure of ROE control = 300 bar [4350 psi]. By applying at port X2 a pilot pressure of 10 bar
[145 psi] , the pressure setting comes to 130 bar [1885 psi] (300-(10x17)=130) (4350 - (145X17)=1885). Should it be required
to swivel the motor to Vg max independently from the operating pressure, a pilot pressure of 20 bar [290 psi] should be applied at
port X2.
Swivel range from Vg min to Vg max (assembly type 2 as per our ordering code). Start of control adjustable between 100 and 350 bar
[1450 and 5000 psi].
Size:
i: 055-075-108-160
055 - 075 - 108 - 160
75-108-160
p
psi bar
B S1 X2 psi bar
6500 450
Mb Y1
6000
400
5500
5000 350
Setting field
3500 250
Pressure
A S2
3000
200
Size:
200 2500
i: 200 2000
150
F1 S1
B
1500 100
B Y1 1000
X2 50
500
0
0 0.2 0.4 0.6 0.8 1 1.2
Vgmin Torque
A Vgmax
T/Tat 400 bar [5946 psi]
A S2
DC5A1G1_0000000 - 01/22
SH7V-M/01
Working pressure control Δp 100 bar with electrical override ROS M27
ROS control is a pressure related control which permits the changing of displacement Vg min to Vg max when working pressure exceeds
setting threshold, so that the motor works at Vg min when low torque and high speed are required and at Vg max when high torque
and low speed are required. The motor stands at Vg min till working pressure reaches setting threshold. Δp of working pressure that
allows the changing of diaplacement from minimum to maximum is 100 bar ( such as ROE control ).
This pressure related control can be overridden by an electrical signal; when solenoid is energized , the motor reaches maximum
displacement without stopping in an intermediate position. Swivel range from Vg min to Vg max (assembly type 2 as per our ordering
code).
Setting pressure range is 100-300 bar.
Size: Size:
055 - 075 -055-075-108-160
Dimensioni: 108 - 160 Dimensioni:
200 200
Size: 055-075-108-160 Size: 200
B F2 F1 Y1 F1
B S1
Ma
B Y1
Vg min
X1
Vgmin
Mb Vg max
A Vgmax
A S2 A S2
S1
DC5A1G1_0000000 - 01/22
SH7V-M/01
M28 SH7V 055 - Motor dimensions
172.4 [6.79]
149.9 [5.9]
74 [2.91]
77 [3.03]
72 [2.83] Ø1 ]
3 99
31 [1.22] [ ∅ 150 [5.9] .2
M10 0.5 ∅6
[
35.8 [1.41]
Depth 19 [0.74] 10 [0.39] S1 1] 6 0
73 [2.87]
Ø1
25.3 [1]
B
[2]
A
∅125 [ ∅4.921]
50.8
150 [5.9]
Y1
14°
A
C 23.8
S2 [0.93
15 [0.59] 7 ]
61.5 [2.42]
45°
45°
143.1 [5.64]
126.8 [4.99]
142.2 [5.6]
Max. stroke adjuster 151.3 [5.96]
214.6 [8.45]
290.3 [11.43]
150 [5.91] 196.5 [7.74]
Min. stroke adjuster
72 [2.83] 98 [3.86]
Ø1
4 146 [5.748] 5]
74 [2.91]
Y1 20 [0.79] .3 .3
3/8" - 16 UNC 2B [0. [6
56 1.2
Depth 21 [0.826] ] 6
43.3 [1.71]
12.7 [0.5] S1 Ø1
25.3 [1]
A B
[2]
146 [5.748]
∅127 [ ∅5]
50.8
14°
C 23.8
S2 [0.93
17 [0.67] 7]
82 [3.23]
91.2 [3.59]
45°
268.8 [10.58] A 0' 0'
45°
Max. stroke adjuster
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 055 - Shafts dimensions for mounting flange ISO 4 bolts (OC) M29
7 Shaft end
W SAM
INDRICO/PARALLEL KEYED SCANALATO/SPLINED
Parallel Splined
CAW
0 mm [1.181 in] keyed shaft SAM
W35x2x30x16 - DIN 5480
shaft
ø34.5 [1.358]
ø30 k6 [1.18]
Key 8x7x508x7x50
Linguetta [0.31x0.28x1.97]
UNI 6604
Spline W35x2x30x16 - DIN 5480
UNI 6604UNI 6604 Key
8x7x50
33 [1.3]
M12
M10
28 [1.1]
22 [0.87] 32 [1.26]
32 [1.26]
32 [1.26]
72 [2.84]
92 [3.62]
ALATO/SPLINED S12
x30x14 - DIN 5480 SCANALATO/SPLINED
14T 12/24 DP
Splined Splined
SAI shaft S12 3/8” 16 UNC-2B shaft
ø31.15 [1.226]
ø29.6 [1.17]
22 [0.87]
26.7 [1.05]
24 [0.95]
32 [1.26] 32 [1.26]
67 [2.64] 32 [1.26]
79.6 [3.14]
DRICO/PARALLEL KEYED
5 mm [1.25 in]
Parallel
C17 keyed shaft
3/8” 16 UNC-2B
ø31.75 [1.25]
Key 7.93x7.3x40
Linguetta 7.93x7.3x40
35.1 [1.38]
[0.31x0.29x1.57]
7.93x7.3x40 Key
32 [1.26]
32 [1.26]
79.6 [3.14]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M30 SH7V 055 - Shafts dimensions for mounting flange SAE-C 4 bolts (O5)
SAM
W 7 Shaft end SCANALATO/SPLINED
NDRICO/PARALLEL KEYED W35x2x30x16 - DIN 5480
mm [1.181 in] Parallel Splined
CAW keyed shaft SAM shaft
ø34.5 [1.358]
ø30 k6 [1.18]
Linguetta
Key 8x7x508x7x50 UNI 6604
[0.31x0.28x1.97]
Spline W35x2x30x16 - DIN 5480
8x7x50
UNI 6604UNI 6604 Key
33 [1.3]
M12
M10
28 [1.1]
22 [0.87]
8 [0.31] 32 [1.26]
8 [0.31]
48 [1.89]
68 [2.68]
S12
SCANALATO/SPLINED
LATO/SPLINED
14T 12/24 DP
30x14 - DIN 5480 Splined Splined
SAI shaft S12 shaft
ø31.15 [1.226]
3/8” 16 UNC-2B
ø29.6 [1.17]
24 [0.95] 32 [1.26]
8 [0.31] 8 [0.31]
43 [1.69]
55.6 [2.19]
NDRICO/PARALLEL KEYED
75 mm [1.25 in]
Parallel
C17 keyed shaft
3/8” 16 UNC-2B
ø31.75 [1.25]
Linguetta
Key 7.93x7.3x40
7.93x7.3x40
35.1 [1.38]
7.93x7.3x40 Key
[0.31x0.29x1.57]
32 [1.26]
8 [0.31]
55.6 [2.19]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 055 - Controls dimensions for mounting flange ISO 4 bolts (OC) (Displ. setting 1) M31
10 Control
175.7 [6.92]
175.7 [6.92]
102.8 [4.05]
102.8 [4.05]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
pressure adjustment
130.2 [5.13] 107.8 [4.24] 130.2 [5.13] 58.3 [2.29]
252.5 [9.94]
252.5 [9.94]
143.2 [5.64]
143.2 [5.64]
175.7 [6.92]
102.8 [4.05]
175.7 [6.92]
102.8 [4.05]
Taratura pressione
Control starting
inizio regolazione
pressure adjustment
Control starting
X2 X2
pressure adjustment
67 [2.64] 108 [4.25] 67 [2.64] 58.5 [2.3]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
REN Control
Regolatore REN RIN Regolatore RIN
Control
REN Control RIN Control
152.8 [6.01]
152.8 [6.01]
111.5 [4.39]
122.8 [4.83]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M32 SH7V 055 - Controls dimensions for mounting flange ISO 4 bolts (OC) (Displ. setting 1)
10 Control
152.8 [6.01]
152.8 [6.01]
111.7 [4.4]
122.8 [4.83]
X2: Piloting port - 1/4 G (BSPP)
Regolatore RED
RID Control Regolatore RID RED Control RED Control
RID Control
129.5 [5.1]
X3
129.5 [5.1] 279.1 [10.99] 52.5 [2.07]
266.2 [10.48] X3
245 [9.65] 52.5 [2.07]
X2
192.9 [7.59]
152.8 [6.01]
152.8 [6.01]
122.8 [4.83]
111.7 [4.4]
92.6 [3.64]
92.6 [3.64]
X2: Piloting port - 1/4 G (BSPP) X3: Double step piloting port - 1/4 G (BSPP)
X3: Double step piloting port - 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 055 - Controls dimensions for mounting flange ISO 4 bolts (OC) (Displ. setting 2) M33
10 Control
Regolatore 2EN
2EN Control
RPE Control Regolatore RPE 2EN Control
RPE Control
146.8 [5.78]
175.7 [6.92]
123.3 [4.85]
102.8 [4.05]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
pressure adjustment
55.2 [2.17] 108 [4.25]
Regolatore 2IN
2IN Control
2IN Control RIN Control
Regolatore RIN
RIN Control
102.8 [4.05]
123.2 [4.85]
88.7 [3.49]
185.5 [7.31]
180.4 [7.1]
X2
172.5 [6.79]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
102.8 [4.05]
258.6 [10.18]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M34 SH7V 055 - Controls dimensions for mounting flange ISO 4 bolts (OC) (Displ. setting 2)
10 Control
Regolatore RPI
ROI Control Regolatore ROI
ROI Control
RPI Control
RPI Control
185.6 [7.31]
185.6 [7.31]
102.8 [4.05]
102.8 [4.05]
180.4 [7.1]
180.4 [7.1]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
102.8 [4.05]
102.8 [4.05]
258.6 [10.18]
258.6 [10.18]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 055 - Controls dimensions for mounting flange SAE-C 4 bolts (O5) (Displ. setting 1) M35
10 Control
175.7 [6.92]
102.8 [4.05]
102.8 [4.05]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
pressure adjustment
130.1 [5.12] 107.9 [4.25] 130.1 [5.12] 58.4 [2.3]
143.2 [5.64]
143.2 [5.637]
175.8 [6.92]
96.5 [3.8]
175.8 [6.92]
96.6 [3.8]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
X2 pressure adjustment X2
67.1 [2.64] 58.4 [2.3]
67 [2.64] 108 [4.25]
X2: Piloting port - 7/16” - 20 UNF X2: Piloting port - 7/16” - 20 UNF
122.8 [4.83]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M36 SH7V 055 - Controls dimensions for mounting flange SAE-C 4 bolts (O5) (Displ. setting 1)
10 Control
Regolatore REE
RIE Control Regolatore RIE REE Control REE Control
RIE Control
Taratura pressione
inizio regolazione
Taratura pressione
Control starting
inizio regolazione
Control starting pressure adjustment
Control adjustment
pressure starting 103.5 [4.07]
pressure adjustment 303.1 [11.93] 52.5 [2.07]
290.2 [11.43] 103.6 [4.08]
269 [10.59] 52.4 [2.06]
X2
192.9 [7.59]
152.8 [6.01]
152.7 [6.01]
111.7 [4.4]
122.8 [4.83]
Regolatore RED
RED Control
RID Control Regolatore RID
RID Control
RED Control
150.5 [5.92]
X3
303.1 [11.93] X3 52.5 [2.07]
290.2 [11.43] 150.6 [5.93]
269 [10.59] X2 52.4 [2.06]
192.9 [7.59]
152.8 [6.01]
152.7 [6.01]
111.7 [4.4]
92.6 [3.64]
122.8 [4.83]
92.6 [3.64]
X2: Piloting port - 7/16” - 20 UNF X3: Double step piloting port - 7/16” - 20 UNF
X3: Double step piloting port - 7/16” - 20 UNF
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 055 - Controls dimensions for mounting flange SAE-C 4 bolts (O5) (Displ. setting 2) M37
10 Control
276.5 [10.89]
306.8 [12.08]
175.8 [6.92]
102.8 [4.05]
102.8 [4.05]
258.6 [10.18]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
pressure adjustment
55.2 [2.17] 108 [4.25]
Regolatore 2IN
2IN Control
2IN Control RIN Control
Regolatore RIN
RIN Control
102.8 [4.05]
123.2 [4.85]
88.7 [3.49]
185.5 [7.31]
180.4 [7.1]
X2
196.5 [7.74]
X2: Piloting port - 7/16” - 20 UNF X2: Piloting port - 7/16” - 20 UNF
Regolatore ROE
Regolatore REN ROE Control
REN Control
REN Control ROE Control
306.7 [12.07]
306.8 [12.08]
102.8 [4.05]
185.5 [7.31]
102.8 [4.05]
258.6 [10.18]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M38 SH7V 055 - Controls dimensions for mounting flange SAE-C 4 bolts (O5) (Displ. setting 2)
10 Control
185.6 [7.31]
102.8 [4.05]
102.8 [4.05]
180.4 [7.1]
180.4 [7.1]
196.3 [7.73] 51.5 [2.03] 50.3 [1.98] 196.3 [7.73] 51.5 [2.03] 50.3 [1.98]
X2 X2
X2: Piloting port - 7/16” - 20 UNF X2: Piloting port - 7/16” - 20 UNF
306.8 [12.08]
306.8 [12.08]
102.8 [4.05]
102.8 [4.05]
258.6 [10.18]
258.6 [10.18]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 075 - Motor dimensions M39
277.1 [10.91]
192.9 [7.594]
Min. stroke adjuster
164 [6.46] 83.7 [3.295]
82 [3.228] 31 [1.22]
80.5 [3.17]
M12 7]
Depth 19 [0.74] . 08
Ø1
4
164 [6.46] Ø7
10 [0.39] [ Ø [
S1 0.5 8 0
5] Ø1
]
[2.25
A B
57.15
∅140 [5.511]
164 [6.46]
157.2 [6.19]
149.9 [5.9]
Y1
14°
C A
S2
14 [0.551]
73.5 [2.893]
27.8 [1.094]
80.9 [3.19]
38.8 [1.527]
27.76
[1.09 45°
145.8 [5.74]
3] 45°
Max. stroke adjuster
170.3 [6.7]
237.1 [9.334]
Depth 19 [0.74] S1 6
∅ 14.5 [
∅ 0.57] ∅1
A B
∅127 [ ∅5]
150 [5.91]
157.2 [6.19]
149.9 [5.9]
Y1
14°
C A
1]
A
30.5 [1.2] S2
[2.25
93 [3.661]
57.2
261.1 [10.279]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M40 SH7V 075 - Shafts dimensions for mounting flange ISO 4 bolts (OD)
7 Shaft end
SAM
CAY
CAY Parallel
CILINDRICO/PARALLEL
keyed KEYED
shaft SAM Splined
SCANALATO/SPLINED shaft
W35x2x30x16 - DIN 5480
ø35 mm [1.377 in]
Linguetta
Key 10x8x56
10x8x56 UNI 6604
[0.39x0.31x2.2]
ø34.3 [1.35]
ø35 k6 [1.38]
0.39x0.31x2.2
UNI 6604 UNI 6604 Key
38 [1.5]
M12
M12
28 [1.1]
28 [1.1]
29 [1.14]
32 [1.26]
32 [1.26]
72 [2.84]
102 [4.02]
S12
AO SCANALATO/SPLINED
Splined Splined
SAO
CANALATO/SPLINED
shaft
W40x2x30x18 - DIN 5480
14T 12/24 S12
DP
shaft
ø30.8 [1.21]
M12
28 [1.1] 32 [1.26]
32 [1.26] 32 [1.26]
79.6 [3.14]
77 [3.03]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 075 - Shafts dimensions for mounting flange SAE-C 4 bolts (O5) M41
7 Shaft end
SAM
Parallel
CAY keyed shaft SAM Splined
SCANALATO/SPLINED
shaft
CAY W35x2x30x16 - DIN 5480
CILINDRICO/PARALLEL KEYED
ø35 mm [1.377 in] Spline W35x2x30x16 - DIN 5480
ø34.1 [1.34]
Key 10x8x56
Linguetta [0.39x0.31x2.2]
10x8x56 UNI 6604
ø35 k6 [1.38]
UNI 6604
0.39x0.31x2.2 UNI 6604 Key
38 [1.5]
M12
M12
28 [1.1]
28 [1.1] 30 [1.18]
8 [0.31]
78 [3.07] 48 [1.89]
Splined Splined
SAO shaft S12 shaft
SAO S12
SCANALATO/SPLINED SCANALATO/SPLINED
W40x2x30x18 - DIN 5480 14T 12/24 DP
8 [0.31]
3/8” 16 UNC-2B
ø39.3 [1.55]
8 [0.31]
ø30.8 [1.21]
M12
28 [1.1] 32 [1.26]
55.6 [2.19]
53 [2.09]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M42 SH7V 075 - Controls dimensions for mounting flange ISO 4 bolts (OD) (Displ. setting 1)
10 Control
277.1 [10.91]
277.1 [10.91]
110.2 [4.34]
188.1 [7.41]
188.1 [7.41]
110.2 [4.34]
Regolatore 2IN
2IN Control
277.1 [10.91]
277.1 [10.91]
149.9 [5.9]
149.9 [5.9]
188.1 [7.41]
188.1 [7.41]
110.2 [4.34]
110.2 [4.34]
Control starting
X2 pressure adjustment X2
67 [2.64] 67 [2.64] 58.5 [2.3]
110 [4.33]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
REN Control
Regolatore REN RIN Control
Regolatore RIN
REN Control
RIN Control
160.4 [6.32]
116.7 [4.59]
125.4 [4.94]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 075 - Controls dimensions for mounting flange ISO 4 bolts (OD) (Displ. setting 1) M43
10 Control
Regolatore REE
RIE ControlRegolatore RIE REE Control
REE Control
RIE Control
302 [11.89]
298.2 [11.74]
268.7 [10.58]
X2
194.6 [7.66]
160.4 [6.32] 125.4 [4.94]
160.4 [6.32]
X2: Piloting port - 1/4 G (BSPP)
298.2 [11.74]
268.7 [10.58] X3
X2
194.6 [7.6]
160.4 [6.32]
160.4 [6.32]
116.7 [4.59]
125.4 [4.94]
95.3 [3.75]
X2: Piloting port - 1/4 G (BSPP) X3: Double step piloting port - 1/4 G (BSPP)
X3: Double step piloting port - 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
SH7V-M/01
M44 SH7V 075 - Controls dimensions for mounting flange ISO 4 bolts (OD) (Displ. setting 2)
10 Control
130.2 [5.13]
110.2 [4.34]
166 [6.53]
Control starting
pressure adjustment
55.2 [2.17]
110 [4.33]
87.6 [3.45]
102.6 [4.04]
186.1 [7.32]
190.5 [7.5]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
102.7 [4.04]
195.5 [7.7]
265.7 [10.46]
53 [2.09] 40 [1.57]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 075 - Controls dimensions for mounting flange ISO 4 bolts (OD) (Displ. setting 2) M45
10 Control
ROI Control
Regolatore ROI
RPI Control
Regolatore RPI
ROI Control RPI Control
102.7 [4.04]
102.7 [4.04]
190.5 [7.5]
195.5 [7.7]
190.5 [7.5]
195.5 [7.7]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
102.4 [4.03]
102.4 [4.03]
265.7 [10.46]
265.7 [10.46]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M46 SH7V 075 - Controls dimensions for mounting flange SAE-C 4 bolts (05) (Displ. setting 1)
10 Control
110.2 [4.34]
188.1 [7.41]
188.1 [7.41]
110.2 [4.34]
Control starting
pressure adjustment
Regolatore 2IN
2IE Control
149.9 [5.9]
149.9 [5.9]
110.5 [4.35]
110.5 [4.35]
187.8 [7.4]
187.8 [7.4]
Control starting
pressure adjustment
X2 X2
67 [2.64] 67 [2.64] 58.5 [2.3]
110 [4.33]
Regolatore REN
RIN ControlRegolatore RIN REN ControlREN Control
RIN Control
160.4 [6.32]
160.4 [6.32]
125.4 [4.94]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 075 - Controls dimensions for mounting flange SAE-C 4 bolts (05) (Displ. setting 1) M47
10 Control
Regolatore REE
Regolatore RIE
RIE Control RIE Control REE ControlREE Control
194.6 [7.66]
160.4 [6.32] 125.4 [4.94]
117 [4.6]
160.4 [6.32]
X2: Piloting port - 7/16”-20 UNF
194.6 [7.66]
117 [4.6]
160.4 [6.32]
160.4 [6.32]
95.3 [3.75]
95.3 [3.75]
125.4 [4.94]
X2: Piloting port - 7/16”-20 UNF X3: Double step piloting port - 7/16”-20 UNF
X3: Double step piloting port - 7/16”-20 UNF
DC5A1G1_0000000 - 01/22
SH7V-M/01
M48 SH7V 075 - Controls dimensions for mounting flange SAE-C 4 bolts (05) (Displ. setting 2)
10 Control
Regolatore 2EN
RPE Control 2EN 2EN Control
Control
166.1 [6.54]
130.2 [5.13]
110.5 [4.35]
187.8 [7.4]
55.2 [2.17]
110 [4.33]
185.8 [7.31]
87.6 [3.45]
102.6 [4.04]
190.5 [7.5]
X2 45.8 [1.8]
57 [2.24]
217.2 [8.55]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
102.7 [4.04]
195.4 [7.69]
265.7 [10.46]
53 [2.09] 40 [1.57]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 075 - Controls dimensions for mounting flange SAE-C 4 bolts (05) (Displ. setting 2) M49
10 Control
102.7 [4.04]
190.5 [7.5]
195.4 [7.69]
190.5 [7.5]
X2 X2
57 [2.24] 45.8 [1.8] 57 [2.24] 45.8 [1.8]
215.4 [8.48] 215.4 [8.48]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
102.4 [4.03]
265.7 [10.46]
265.7 [10.46]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M50 SH7V 108 - Motor dimensions
302.6 [11.913]
93 [3.66]
190 [7.48] ]
82 [3.23] 35.2 [1.38] .87
Ø7
M12 7.1 [0.28] S1
0 0[
33.9 [1.33]
44.3 [1.74]
Depth 26 [1.02]
Ø2
97 [3.82]
∅160 [ ∅6.299]
14°
A B
190 [7.48]
7]
[ Ø0.6
Ø17
173,6 [6,83]
174,6 [6,87]
Y1
B
C
1]
S2
[2.25
17.9 [0.7]
95.5 [3.76]
57.2
27.8
Max. stroke adjuster [1.09 45°
173.6 [6.84] 4] 45°
198.6 [7.82]
271,1 [10,66]
335 [13.189]
200 [7.87] ]
82 [3.23] 13 [0.511]
.996
Ø8
7/16"-14 UNC 2B S1
8.5[
44.4 [1.75]
97.2 [3.83]
Depth 26 [1.02] 2
Ø2
34 [1.34]
∅152.4 [ ∅6]
A B
200 [7.87]
14°
0.83]
Ø21 [ Ø
173,6 [6,83]
174,6 [6,87]
Y1 B
C
1]
S2
32.5 [1.28]
[2.25
127.5 [5.02]
57.2
27.8 45°
Max. stroke adjuster [1.09
] 45°
205.6 [8.1]
230.6 [9.08]
303,1 [11,93]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 108 - Shafts dimensions for mounting flange ISO 4 bolts (OE) M51
7 Shaft end
CAK SAP
CAK Parallel
CILINDRICO/PARALLEL
keyed shaft KEYED SAP Splined
SCANALATO/SPLINED
shaft
ø40 mm [1.56 in] W45x2x30x21 - DIN 5480
Spline W45x2x30x21 - DIN 5480
42 [1.65]
30 [1.18]
12 [0.472]
M12
ø13 [0.511]
ø40 k6 [1.574]
43 [1.69]
ø17 [0.669]
M16
44.5 [1.75]
Key 12x8x63
12x8x63 UNI [0.47x0.31x2.48]
6604 Key/linguetta
UNI 6604
40 [1.58]
80 [3.15] 40 [1.58]
50 [1.97]
Splined
SA0 shaft
A0
CANALATO/SPLINED
40x2x30x18 - DIN 5480
Spline W40x2x30x18 - DIN 5480
35 [1.38]
28 [1.1]
9.5 [0.374]
M12
ø13 [0.511]
39.3 [1.55]
40 [1.58]
45 [1.77]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M52 SH7V 108 - Shafts dimensions for mounting flange SAE-C 4 bolts (08)
7 Shaft end
Parallel S15
18
C18 keyed shaft S15 Splined
shaft
SCANALATO/SPLINED
LINDRICO/PARALLEL KEYED 13T 8/16 DP
Spline 13T 8/16 DP
44.45 mm [1.75 in]
37.9 [1.49]
Key 11.11x6x60 [0.44x0.36x2.36]
11.11x9.2x60 Key/linguetta
UNI 6604 36 [1.42]
36 [1.42]
13 [0.511]
13 [0.511]
-0.05 [1.751 -0.0019]
1/2”-20UNF
1/2”-20UNF
ø13 [0.511]
ø13 [0.511]
49.2 [1.94]
44.2 [1.74]
0
8 [0.314]
8 [0.314]
0
66.5 [2.62]
44.5
66.5 [2.62]
Splined
20
S20 shaft
CANALATO/SPLINED
7T 16/32 DPD
Spline 27T 16/32 DPD
55 [2.17]
36 [1.42]
13 [0.511]
ø13 [0.511]
1/2”-20UNF
44.3 [1.74]
8 [0.314]
67.5 [2.66]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 108 - Controls dimensions for mounting flange ISO 4 bolts (OE) (Displ. setting 1) M53
10 Control
Regolatore 2EN
2EN Control
122.5 [4.82]
204.8 [8.06]
122.5 [4.82]
204.8 [8.06]
Control starting
pressure adjustment
134 [5.28] 106 [4.17] 134 [5.28] 54.5 [2.15]
Regolatore 2IN
2IE Control 2IN Control 2IN Control
303 [11.93]
303 [11.93]
122.5 [4.82]
173 [6.81]
204.8 [8.06]
122.5 [4.82]
173 [6.81]
204.8 [8.06]
Control starting
pressure adjustment
X2 X2
71 [2.8] 71 [2.8] 54.5 [2.15]
106 [4.17]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
Taratura pressione
Control starting
inizio regolazione
pressure adjustment
Control starting
pressure adjustment 344 [13.54] 43.8 [1.72] 59.5 [2.34]
344 [13.54] 99 [3.9] 59.5 [2.34]
202.4 [7.97]
202.4 [7.97]
183.9 [7.24]
183.9 [7.24]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M54 SH7V 108 - Controls dimensions for mounting flange ISO 4 bolts (OE) (Displ. setting 1)
10 Control
Regolatore RIE Regolatore RIN
RIN Control
RIE Control RIE Control RIN Control
Taratura pressione
inizio regolazione
Controlstarting
Control starting
pressureadjustment
pressure adjustment 338.8 [13.34]
338.8 [13.34] 311.2 [12.25]
43.8 [1.72] 58.5 [2.3]
99 [3.9] 58.5 [2.3] X2
311.2 [12.25]
X2
140.3 [5.52]
127.1 [5.00]
140.3 [5.52]
127.1 [5.00]
183.9 [7.24]
183.9 [7.24]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
183.9 [7.24]
105.8 [4.17]
183.9 [7.24]
105.8 [4.17]
X2: Piloting port - 1/4 G (BSPP) X3: Double step piloting port - 1/4 G (BSPP)
X3: Double step piloting port - 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 108 - Controls dimensions for mounting flange ISO 4 bolts (OE) (Displ. setting 2) M55
10 Control
Regolatore 2EN
2EN Control
RPE Control 2EN Control
Regolatore RPE
RPE Control
303 [11.93]
137.6 [5.42]
183.9 [7.24]
122.5 [4.82]
204.8 [8.06]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
59.2 [2.33] 139 [5.47] pressure adjustment
103.9 [4.09]
122.5 [4.82]
183.9 [7.24]
289.7 [11.41]
Regolatore ROE
RIN Control
Regolatore RIN ROE Control ROE Control
RIN Control
319.8 [12.59]
319.8 [12.59]
122.5 [4.82]
219.3 [8.63]
122.5 [4.82]
214.4 [8.44]
219.9 [8.66]
55 [2.17] 40 [1.57]
226.1 [8.9] X2 58.5 [2.3] 43.8 [1.72]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M56 SH7V 108 - Controls dimensions for mounting flange ISO 4 bolts (OE) (Displ. setting 2)
10 Control
Regolatore RPI
Regolatore ROI RPI Control
ROI Control ROI Control RPI Control
319.8 [12.59]
319.8 [12.59]
122.5 [4.82]
214.5 [8.44]
219.3 [8.63]
122.5 [4.82]
214.5 [8.44]
219.3 [8.63]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
122.5 [4.82]
122.5 [4.82]
289.7 [11.41]
289.7 [11.41]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 108 - Controls dimensions for mounting flange SAE-C 4 bolts (08) (Displ. setting 1) M57
10 Control
Regolatore 2EN
2EN Control
2EE Control 2EN Control
122.5 [4.82]
122.5 [4.82]
204.8 [8.06]
204.8 [8.06]
Control starting
pressure adjustment
134 [5.28] 106 [4.17]
134 [5.28] 54.5 [2.15]
Regolatore 2IN
2IE Control 2IN Control
2IN Control
173.6 [6.83]
122.5 [4.82]
204.8 [8.06]
Control starting
pressure adjustment
X2
71 [2.8] X2
106 [4.17] 71 [2.8] 54.5 [2.15]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
Regolatore REN
REE Control Regolatore REE REN Control
REN Control
REE Control
Taratura pressione
inizio regolazione 59.5 [2.34]
Control
Control starting
starting
pressure
pressure adjustment
adjustment 376 [14.8] 43.8 [1.72]
59.5 [2.34]
376 [14.8] 99 [3.9]
202.4 [7.97]
202.4 [7.97]
183.9 [7.24]
183.9 [7.24]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M58 SH7V 108 - Controls dimensions for mounting flange SAE-C 4 bolts (08) (Displ. setting 1)
10 Control
Taratura pressione
inizio regolazione
Controlstarting
Control starting
pressureadjustment
pressure adjustment
370.8 [14.6] 58.5 [2.3]
370.8 [14.6] 58.5 [2.3] 343.2 [13.51] 43.8 [1.72]
343.2 [13.51] X2 99 [3.9] X2
140.3 [5.52]
127.1 [5.00]
140.3 [5.52]
127.1 [5.00]
183.9 [7.24]
183.9 [7.24]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
59.5 [2.34]
376 [14.8] 146 [5.75]
370.8 [14.6] 58.5 [2.3] X3
X3
343.2 [13.51] 146 [5.75]
X2
202.4 [7.97]
140.3 [5.52]
127.1 [5.00]
183.9 [7.24]
183.9 [7.24]
105.8 [4.17]
105.8 [4.17]
X2: Piloting port - 7/16”-20 UNF X3: Double step piloting port - 7/16”-20 UNF
X3: Double step piloting port - 7/16”-20 UNF
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 108 - Controls dimensions for mounting flange SAE-C 4 bolts (08) (Displ. setting 2) M59
10 Control
335 [13.19]
341.9 [13.46] 51 [2.01] 134 [5.28]
137.6 [5.42]
122.5 [4.82]
204.8 [8.06]
183.9 [7.24]
Control starting
pressure adjustment
59.2 [2.33]
106 [4.17]
341.9 [13.46]
299.8 [11.8] 51 [2.01] 71 [2.8] 351.8 [13.85]
X2
137.6 [5.42]
183.9 [7.24]
122.5 [4.82]
103.9 [4.09]
289.7 [11.41]
122.5 [4.82]
214.4 [8.44]
219.9 [8.66]
219.3 [8.63]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M60 SH7V 108 - Controls dimensions for mounting flange SAE-C 4 bolts (08) (Displ. setting 2)
10 Control
Regolatore RPI
Regolatore ROI
RPI Control
ROI Control ROI Control RPI Control
122.5 [4.82]
122.5 [4.82]
214.4 [8.44]
219.3 [8.63]
214.4 [8.44]
219.3 [8.63]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
122.5 [4.82]
122.5 [4.82]
289.7 [11.41]
289.7 [11.41]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 160 - Motor dimensions M61
312.3 [12.294]
39 [1.54]
105 [4.13]
92 [3.62] 99.5 [3.92]
Min. stroke adjuster 210 [8.27]
S1
M14
Depth 28 [1.09]
]
Ø8.82
n 180 [Ø7,08]
[
Ø224
A B
210 [8.27]
A
14°
108 [4,25]
182,2 [7,17]
184,9 [7,27]
Ø18
[
38,2 [1,50]
30 [1.18]
Ø0.7
48,1 [1,89]
1 ]
Y1 C
5]
29.5 [1.16] S2
[2,62
99.5 [3.92]
66,7
31.6 45°
Max. stroke adjuster
[1.24
4] 45°
189.7 [7.47]
214.8 [8.46]
290,6 [11,44]
344.3 [13.553]
282.8 [11.13]
173.5 [6.83] 200 [7.87]
Min. stroke adjuster
92 [3.62] S1
1/2"-13 UNC 2B
Depth 28 [1.09] 9]
Ø8.9
8 .5 [
Ø22
A
Ø152.4 [Ø6]
A B
200 [7.87]
14°
182,2 [7,17]
184,9 [7,27]
Ø20.5
38,2 [1,50]
48,1 [1,89]
[ Ø
0.81
]
Y1
32 [1.26] C
5]
108 [4.25]
[2,62
S2
Max. stroke adjuster
66,7
131,5 [5,17]
31.6
[1.24 45° 45°
221,7 [8,72] 4]
246,8 [9,71]
322,6 [12,70]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M62 SH7V 160 - Shafts dimensions for mounting flange ISO 4 bolts (OF)
7 Shaft end
SAP
CAJ SCANALATO/SPLINED
CAJ Parallel
CILINDRICO/PARALLEL KEYED
keyed shaft SAP
W45x2x30x21 - DIN
Splined
5480 shaft
ø45 mm [1.772 in]
Spline W45x2x30x21 - DIN 5480
50 [1.97]
A 14x9x80 DIN 6885
Key
36 [1.42] Key/linguetta
A 14x9x80 [0.511x0.354x3.15] DIN 6885
42 [1.65]
12 [0.472]
36 [1.42]
M16
M16
ø17 [0.669]
ø17 [0.67]
ø45 k6 [1.771]
48.5 [1.91]
43 [1.69]
40 [1.58]
90 [3.54]
Splined Splined
SAR shaft SA0 shaft
R
SA0
ANALATO/SPLINED
SCANALATO/SPLINED
0x2x30x24 - DIN 5480 Spline W50x2x30x24 - DIN 5480 W40x2x30x18 - DIN 5480 Spline W40x2x30x18 - DIN 5480
36 [1.42]
40 [1.57]
12 [0.472]
36 [1.42]
ø17 [0.669]
12 [0.472]
M16
ø17 [0.669]
M16
44 [1.73]
50 [1.97] 41 [1.61]
55 [2.17] 40 [1.57]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 160 - Shafts dimensions for mounting flange SAE-D 4 bolts (08) M63
7 Shaft end
C18
CILINDRICO/PARALLEL KEYED
Parallel Splined
44.45 mmC18
[1.75 in] keyed shaft S15 S15 shaft
SCANALATO/SPLINED
11.11x9.2x60 linguetta
13T 8/16 DP
Key 0.44x0.36x2.36
0.44x0.36x2.36 Key Spline 13T 8/16 DP
UNI 6604
36 [1.42]
55 [2.17]
13 [0.511]
36 [1.42]
13 [0.511]
1/2” - 20 NF
ø44.45 [1.75]
ø13 [0.511]
49.1 [1.94]
1/2”-20 UNF
ø13 [0.511]
7.9 [0.311]
75.5 [2.97]
Splined Splined
0
S20 shaft S19
S19 shaft
CANALATO/SPLINED SCANALATO/SPLINED
T 16/32 DPD 15T 8/16 DP
27T 16/32 DPD Spline 15T 8/16 DPD
55 [2.17]
53 [2.09]
36 [1.42] 36 [1.42]
13 [0.511] 13 [0.511]
ø13 [0.511]
1/2”-20 UNF
1/2”-20 UNF
ø13 [0.511]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M64 SH7V 160 - Controls dimensions for mounting flange ISO 4 bolts (OF) (Displ. setting 1)
10 Control
Regolatore 2EN
2EE Control 2EN Control
2EN Control
312.3 [12.29]
312.3 [12.29]
Control starting
pressure adjustment
133.2 [5.24]
133.2 [5.24]
213.8 [8.42]
213.8 [8.42]
103 [4.06]
137 [5.39] 51.5 [2.03] 137 [5.39]
240 [9.45]
133.1 [5.24]
187.6 [7.39]
187.6 [7.39]
213.8 [8.42]
213.8 [8.42]
Control starting
pressure adjustment
X2 X2
74 [2.91] 103 [4.06]
74 [2.91] 51.5 [2.03]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
363.8 [14.32]
206.2 [8.12]
192.1 [7.56]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 160 - Controls dimensions for mounting flange ISO 4 bolts (OF) (Displ. setting 1) M65
10 Control
Regolatore RIN
RIE Control Regolatore RIE RIN Control RIN Control
RIE Control
143.7 [5.66]
143.7 [5.66]
192.1 [7.56]
130.9 [5.15]
130.9 [5.15]
192.1 [7.56]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
206.2 [8.12]
130.9 [5.15]
111.4 [4.39]
192.1 [7.56]
111.4 [4.39]
192.1 [7.56]
X2: Piloting port - 1/4 G (BSPP) X3: Double step piloting port - 1/4 G (BSPP)
X3: Double step piloting port - 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
SH7V-M/01
M66 SH7V 160 - Controls dimensions for mounting flange ISO 4 bolts (OF) (Displ. setting 2)
10 Control
Regolatore 2EN
RPE Control 2EN Control 2EN Control
Control starting
312.3 [12.29] 137 [5.39] 51.5 [2.03] 328.7 [12.94]
pressure adjustment
140 [5.51]
133.2 [5.24]
192.1 [7.56]
213.8 [8.42]
103 [4.06]
62.2 [2.45]
X2
140 [5.51]
119.2 [4.69]
108.9 [4.29]
192.1 [7.56]
300.5 [11.83]
Regolatore ROE
RIN Control Regolatore RIN ROE Control ROE Control
RIN Control
230.1 [9.06]
225.2 [8.87]
230.6 [9.08]
66 [2.6] 41 [1.61]
242.3 [9.54] X2 66 [2.6] 45 [1.77]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 160 - Controls dimensions for mounting flange ISO 4 bolts (OF) (Displ. setting 2) M67
10 Control
Regolatore ROI Regolatore RPI
ROI Control RPI Control
ROI Control RPI Control
133.2 [5.24]
133.2 [5.24]
225.2 [8.87]
230.1 [9.06]
225.2 [8.87]
230.1 [9.06]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
332.2 [13.08]
332.2 [13.08]
300.5 [11.83]
119.2 [4.69]
300.5 [11.83]
119.2 [4.69]
66 [2.6] 45 [1.77]
66 [2.6] 45 [1.77]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M68 SH7V 160 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 1)
10 Control
Regolatore 2EN
2EE Control 2EN Control
2EN Control
344.3 [13.55]
Control starting 344.3 [13.55]
pressure adjustment
133.2 [5.24]
213.8 [8.42]
133.2 [5.24]
213.8 [8.42]
103 [4.06] 137 [5.39]
51.5 [2.03]
137 [5.39]
240 [9.45]
Regolatore 2IN
2IE Control 2IN Control
2IN Control
344.3 [13.55]
344.3 [13.55]
Control starting
pressure adjustment
187.6 [7.39]
133.2 [5.24]
213.8 [8.42]
187.6 [7.39]
133.2 [5.24]
213.8 [8.42]
X2 X2
103 [4.06] 74 [2.91]
74 [2.91] 51.5 [2.03]
X2: Piloting port - 7/16”-20 UNF-2B X2: Piloting port - 7/16”-20 UNF-2B
192.1 [7.56]
192.1 [7.56]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 160 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 1) M69
10 Control
Regolatore RIN
Regolatore RIE RIN Control
RIE Control
RIE Control RIN Control
143.7 [5.66]
143.7 [5.66]
130.9 [5.15]
192.1 [7.56]
130.9 [5.15]
192.1 [7.56]
X2: Piloting port - 7/16”-20 UNF-2B X2: Piloting port - 7/16”-20 UNF-2B
206.2 [8.12]
111.4 [4.39]
130.9 [5.15]
192.1 [7.56]
111.4 [4.39]
192.1 [7.56]
X2: Piloting port - 7/16”-20 UNF X3: Double step piloting port - 7/16”-20 UNF
X3: Double step piloting port - 7/16”-20 UNF
DC5A1G1_0000000 - 01/22
SH7V-M/01
M70 SH7V 160 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 2)
10 Control
Regolatore 2EN
RPE Control 2EN Control 2EN Control
Regolatore RPE
RPE Control
Control starting
pressure adjustment
344.3 [13.55] 137 [5.39] 51.5 [2.03] 360.7 [14.2]
140 [5.51]
133.2 [5.24]
192.1 [7.56]
213.8 [8.42]
Regolatore REN
Regolatore 2IN
REN Control
2IN Control
2IN Control REN Control
119.2 [4.69]
102.6 [4.04]
192.1 [7.56]
300.5 [11.83]
66 [2.6] 45 [1.77]
133.2 [5.24]
225.2 [8.87]
230.6 [9.08]
230.1 [9.06]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 160 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 2) M71
10 Control
Regolatore ROI Regolatore RPI
ROI Control RPI Control
ROI Control RPI Control
133.2 [5.24]
133.2 [5.24]
230.1 [9.06]
225.2 [8.87]
225.2 [8.87]
230.1 [9.06]
X2: Piloting port - 7/16”-20 UNF-2B X2: Piloting port - 7/16”-20 UNF-2B
119.2 [4.69]
119.2 [4.69]
300.5 [11.83]
300.5 [11.83]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M72 SH7V 200 - Motor dimensions
158.2 [6.229]
31.8 [2.52]
113.1 [4.455]
120 [4.724]
105 [4.134]
Ø200 [7.874]
236 [9.291]
A
66.7[2.626]
14°
.626]
40.5 [1.595]
66.7 [2
217.7 [8.571]
31.8
S2 [1.25
115 [4.528]
32 [1.26] 2]
99 [3.898]
45° °
Max Stroke Adjustment 45
164 [6.457]
243 [9.567]
391.1 [15.399]
345.6 [13.607] Min. Stroke adjuster
304.5 [11.989] °
45 45°
75 [2.953] 199 [7.835]
27 [1.068] S1 Y1
C
Ø317.5 [12.5]
158.2 [6.229]
115 [4.5258] 133 [5.236]
31.8 [1.252]
Ø165.1 [6.5]
262 [10.315]
A B
.626]
66.7 [2
217.7 [8.571]
66.7 [2.626]
31.8
12.7 [0.5] [1.25
2]
Ø2
32 [1.26]
0.6
131 [5.157] S2
[0.
81
262 [10.315]
1]
164 [6.457]
243 [9.567] Max Stroke adjuster
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 200 - Shafts dimensions M73
7 Shaft end
Splined
SAR shaft
SAR
W50x2x30x24 DIN 5480 Spline W50x2x30x24 - DIN 5480
ø48 [1.89]
M16
36 [1.42]
45 [1.77]
56 [2.20]
84.5 [3.33]
95 [3.74]
7 Shaft end
Splined
S19 shaft
S19
SCANALATO/SPLINED
15T 8/16 DPD 15T 8/16 DP FLAT ROOT SIDE FIT
47.62 [1.87]
M16
36 [1.42]
45 [1.77]
75 [2.95]
12.7 [0.50]
DC5A1G1_0000000 - 01/22
SH7V-M/01
M74 SH7V 200 - Controls dimensions for mounting flange ISO 4 bolts (OG) (Displ. setting 1)
10 Control
441.8 [17.39]
441.3 [17.38]
F1
F1
359 [14.13]
381.7 [15.03]
375.9 [14.80]
F1 F1
381.7 [15.03] 359 [14.13]
F1
F1 359.1 [14.14]
381.7 [15.03]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 200 - Controls dimensions for mounting flange ISO 4 bolts (OG) (Displ. setting 1) M75
10 Control
89.5 3.52
89.5 3.52
Piloting port - 7/16"-20 UNF Control starting 42.5 1.67
Pressure adjustment 42.5 1.67
Y1 Y1
X2
375.7 [14.79]
375.9 [14.80]
F1 F1
381.5 [15.02] 359 [14.13]
89.5 3.52
89.5 [3.52]
Control starting
Pressure adjustment Y1 Double step 42.5 1.67
X2 X3 42.5 [1.67]
Piloting port - 7/16"-20 UNF Y1
X3
441.3 [17.38]
375.7 [14.79]
381.7 [15.03] F1
F1
Control starting 381.7 [15.03]
X2: Piloting port - 7/16"-20 UNF Pressure adjustment
X3: Double step Piloting port - 7/16"-20 UNF
DC5A1G1_0000000 - 01/22
SH7V-M/01
M76 SH7V 200 - Controls dimensions for mounting flange ISO 4 bolts (OG) (Displ. setting 2)
10 Control
F1 Y1
441.8 [17.39]
382.6 [15.06]
Y1
349.9 [13.78] F1
Control starting 89.5 [3.52] 42.5 [1.67]
Pressure adjustment 359 [14.13]
F1
Y1 42.5 [1.67] 89.5 [3.52]
X2
454.8 [17.91]
375.9 [14.80]
Y1
F1
Piloting port - 7/16"-20 UNF 359 [14.13] 349.9 [13.78] 89.5 [3.52] 42.5 [1.67]
F1
Y1 42.5 [1.67] 89.5 [3.52]
X2
383.1 [15.08]
375.9 [14.80]
Y1
F1
Piloting port - 7/16"-20 UNF 359 [14.13] 349.9 [13.78] 89.5 [3.52] 42.5 [1.67]
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 200 - Controls dimensions for mounting flange ISO 4 bolts (OG) (Displ. setting 2) M77
10 Control
F1
F1
383.1 [15.08]
383.1 [15.08]
Y Y1 X2 Y1
X2
Piloting port - 7/16"-20 UNF 349.9 [13.78] 89.5 [3.52] 42.5 [1.67] Piloting port - 7/16"-20 UNF 349.9 [13.78] 89.5 [3.52] 42.5 [1.67]
F1 F1
454.8 [17.91]
454.8 [17.91]
Y1 Y1
DC5A1G1_0000000 - 01/22
SH7V-M/01
M78 SH7V 200 - Controls dimensions for mounting flange SAE-D 4 bolts (10) (Displ. setting 1)
10 Control
441.8 [17.39]
441.3 [17.38]
F1 F1
413.7 [16.29] 391 [15.39]
375.9 14.80
F1 F1
Piloting port - 7/16"-20 UNF 413.7 16.29 Piloting port - 7/16"-20 UNF 391.1 15.40
89.5 3.52
89.5 3.52
42.5 1.67
42.5 1.67
Control starting
Y1
Pressure adjustment Y1
441.8 17.39
17.38
441.3
391.1 15.40 F1
F1
413.7 16.29
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 200 - Controls dimensions for mounting flange SAE-D 4 bolts (10) (Displ. setting 1) M79
10 Control
89.5 3.52
89.5 3.52
375.7 14.79
375.9 14.80
Piloting port - 7/16"-20 UNF F1 F1
413.5 16.28 Piloting port - 7/16"-20 UNF 391.1 15.40
441.3 [17.38]
375.7 [14.79]
410 [16.14] F1
F1
413.7 [16.29]
X2:
X2:Piloting
Piloting portport - 7/16”-20
- 7/16"-20 UNF UNF
X3:
X3:Double
Double stepstep piloting
Piloting port - 7/16”-20
port - 7/16"-20 UNF UNF X3: Double
Double stepport
step Piloting piloting
- 7/16"-20port
UNF - 7/16”-20 UNF
DC5A1G1_0000000 - 01/22
SH7V-M/01
M80 SH7V 200 - Controls dimensions for mounting flange SAE-D 4 bolts (10) (Displ. setting 2)
10 Control
F1 F1
382.6 [15.06]
454.8 [17.91]
Y1
Y1
F1 F1
383.1 [15.08]
454.8 [17.91]
X2 Y1 Y1
Y1
DC5A1G1_0000000 - 01/22
SH7V-M/01
SH7V 200 - Controls dimensions for mounting flange SAE-D 4 bolts (10) (Displ. setting 2) M81
10 Control
F1 F1
383.1 [15.08]
383.1 [15.08]
Y1 X2 Y1
X2
F1
F1
454.8 [17.91]
454.8 [17.91]
Y1
Y1
DC5A1G1_0000000 - 01/22
SH7V-M/01
M82 Flushing valve
For closed circuit operation, the motors can be equipped with built in flushing valve.
B X2
B Y1
Vgmin
A Vgmax
A S2
S1
B X2
B Y1
Vgmin
A Vgmax
A S1 S2
DC5A1G1_0000000 - 01/22
SH7V-M/01
Flushing valve M83
DC5A1G1_0000000 - 01/22
SH7V-M/01
M84 Flushing valve
B S1
Y1
Size
SH7V 055 ISO SH7V 075 ISO SH7V 055 SAE SH7V 075 SAE
A mm [in] 268.3 [10.56] 292.6 [11.51] 323 [12.72] 316.6 [12.46] Vgmin
Vgmax
A S2
34.34
DC5A1G1_0000000 - 01/22
SH7V-M/01
Tachometer M85
TS - TW - TZ
B TS TZ-TW
A
phonic wheel assembles on rotating group
without sensor.
Size
SH7V055 ME SH7V075 ME SH7V108 ME SH7V160 ME SH7V200 ME SH7V55 SE SH7V075 SE SH7V108 SE SH7V160 SE SH7V200 SE
A mm 64 79.9 88.9 96.9 101.9 88 79.9 88.9 96.9 101.9
[inch] [2.52] [3.14] [3.49] [3.81] [4.01] [3.46] [3.14] [3.49] [3.81] [4.01]
B mm 75.5 76.5 86.5 92.5 105 75.5 100.5 120.5 124.5 105
[inch] [2.97] [3.01] [3.40] [3.64] [4.13] [2.97] [3.95] [4.74] [4.90] [4.13]
TW TZ
2-Channel differential-hall effect operating principle (1 square 2-Channel differential-hall effect operating principle Sensor
wave -1 digital for direction of rotation) Output signal PNP with dual-channel output (90°)
Power supply 4.5-16 VDC Power supply 8-32 VDC
Frequency 0 - 20.000 Hz Frequency 0-20.000 Hz
Operating temperature -40°C - +110°C Operating temperature -40°C +125°C
Degree of protection IP67
Sensor connector Deutsch DT04-4P
Electromagnetic compatibility according to EN 60947-5-2
Resistence to schock and vibration in accordance with IEC
68-2-17 IEC 68-2-6
Size
SH7V 055 SH7V 075 SH7V 108 SH7V 160 SH7V 200
DC5A1G1_0000000 - 01/22
SH7V-M/01
DC5A1G1_0000000 - 01/22
SH7VR - Plug-in variable displacement motor for gearbox N1
Index
SH7VR 075 80.58 [4.91] 322 [85] 430 [6235] 480 [6960]
SH7VR 108 112.5 [6.86] 400 [105.6] 430 [6235] 480 [6960]
SH7VR 160 160.8 [9.81] 500 [132] 430 [6235] 480 [6960]
SH7VR series are a family of variable displacement motors, bent axis piston design for operation in both open and closed circuit.
SH7VR series motors are mainly intended for installation in mechanical gearboxes such as track drive and winches gear boxes.
The proven design incorporating the lens shape valve plate, the high quality components and manifacturing tecniques make able
the SH7VR series motors to provide up to 430 bar [6235 psi] continuous and 480 bar [6960 psi] peak performance.
Fully laboratory tested and field proven, these motors assume maximum efficiency and long life even at very bad filtering conditions.
Heavy duty bearings permit high radial and axial loads.
Versatile design includes a variety of control and shaft ends that will adapt the SH7VR series motors to any application both
industrial and mobile.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N2 General information - Features
Simbology:
N/bar l/min
C [lbf/psi]
Load qmax [U.S. gpm]
Maximum flow
N l/min
Fax max [lbf]
Axial pushing load qd [U.S. gpm]
External drain flow
N Nm/bar
Fax max [lbf]
Axial pulling load Tk [lbf.ft/psi]
Torque costant
N Nm
Fq [lbf]
Radial load Tnom [lbf.ft]
Maximum torque at pressure cont.
N Nm
Fq max [lbf]
Maximum permissible radial load Tmax [lbf.ft]
Maximum torque at pressure peak
kg·m2 cm3/rev
J [lbf·ft2]
Moment of inertia Vg [in3/rev]
Displacement
kg kW
m [lbs]
Weight Pmax [hp]
Maximum power at pnom
Fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed.
Viscosities less then 10 cSt are not allowed. A viscosity range of 10÷15 cSt is allowed for extreme operating conditions and for short
periods only. For further information see at Fluids and filtering section.
Operating temperature:
The operating temperature of the oil must be within -25ºC ÷ 115ºC [-13ºF ÷ 239ºF]. The running of the unit with oil temperature higher
than 115ºC [239°F] or lower than -25ºC [-13°F] is not allowed. For further information see at Fluids and filtering section
Filtration:
A correct filtering helps to extend the service life of axial piston units. In order to ensure a correct functioning of the unit, the max.
permissible contamination class is 21/19/16 according to ISO 4406:1999. For further details see at Fluids and filtration section.
Operating pressure:
The maximum permissible pressure on pressure ports is 430 bar [6235 psi] continuous and 480 bar [6960 psi] peak. It two motors
are connected in series, total pressure has to be limited to following values: P1+P2 700 bar max. [10150 psi max].
Case drain pressure:
Maximum permissible case drain pressure is 10 bar [145 psi]. A higher pressure can damage the main shaft seal or reduce its life.
P1 P2 P3
DC5A1G1_0000000 - 01/22
SH7VR-M/01
General information - Features N3
Seals:
Seals used on standard SH7VR series axial piston motors are of FKM seals (Fluoroelastomer - Viton®). In case of use of use special
fluids, contact Dana.
Port plates:
The SH7VR motor port plate has inlet and outlet ports, both lateral (LM cover) and frontal (FM cover). Unused ports are plugged with
blind flanges. The kind of ports to be used must be specified when ordering.
Flushing valve:
The motors can be equipped with built in flushing valve for closed circuit operation.
Installation:
SH7VR series motors can be installed in every position or direction. These axial piston units have separate ports and drain chambers
and so must be always drained. Installation of the unit with shaft in vertical position and above the tank involves some limitations.
For further details see at General installation guidelines.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N4 Technical data
Displacement
055 075 108 160
cm3/rev 61 80.58 112.5 160.8
Displacement Vg max [in3/rev] [3.72] [4.91] [6.86] [9.81]
cm3/rev 30 40 56 80
Displacement standard Vg min [in3/rev] [1.83] [2.44] [3.416] [4.88]
cm3/rev 0 0 0 0
Displacement optional Vg0 [in3/rev] [0] [0] [0] [0]
Max speed at Vg max e qmax nmax rpm 4450 4000 3550 3100
Max speed at Vg < Vg max (2) nmax lim rpm 7000 6150 5600 5000
kg 28 36 47 63
Weight (3) m [lbs] [61.7] [79.3] [103.6] [138.8]
l/min 3 4 5 5
Drainage flow (4) qd [U.S. gpm] [0.79] [1.05] [1.32] [1.32]
(Theorical values, without considering ηhm e ηv; approximate values). Peak operations must not excede 1% of every minute. A
simultaneous maximum pressure and maximum speed not recommended.
Notes:
(1)
Maximum and minimum displacement can be changed with
continuity. When ordering state Vg max and Vg min required. Permissible speed
(2)
Determination of admissible speed nmax value can be
increased by reducing motor maximum displacement. To
1.0
determine the relationship beetwen Vg max and nmax use the
right side chart. Motor maximum admissible speed is nmax lim.
(3)
Approximate values. 0.8
(4)
Maximum value at 250 bar [3625 psi] with mineral oil at
45ºC [113°F] and 35 cSt of viscosity. 0.6
Displacemnet
(Vg / Vg max)
0.4
0.2
0
0 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
Speed
(n / nmax)
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Ordering code N5
The following alphanumeric codes system has been developed to identify all of the configuration options for the SH7VR motors.
Use the model code below to specify the desired features. All alphanumeric digits system of the code must be present when
ordering. We recommend to carefully read the catalogue before filling the ordering code.
1 2 3 4
Maximum displacement 5 6 7 8 9 10 11 12 13 14 15 16
Minimum displacement
Control specification
Flushing valve
Valves feature
Displacement
Mount flange
Serie feature
Port cover
Shaft end
limitation
limitation
Painting
Control
Valves
Series
Motor
1
Series
SH7VR Plug-in variable displacement motor for gearbox
2
Motor
M Motor
3
Displacement
055 55 cm /rev [3.355 in /rev]
3 3
4
Displacement
Maximum displacement limitation
055 075 108 160
From 61 cm3/rev [3.721 in3/rev] Standard
61÷49
to 49 cm3/rev [2.989 in3/rev] 61 cm3/rev [3.721 in3/rev] • – – –
From 80 cm3/rev [4.880 in3/rev] Standard
80÷64
to 64 cm3/rev [3.904 in3/rev] 80 cm3/rev [4.880 in3/rev]
– • – –
From 112 cm3/rev [6.832 in3/rev] Standard
112÷91
to 91 cm3/rev [5.551 in3/rev] 112 cm3/rev [6.832 in3/rev]
– – • –
From 160 cm3/rev [9.760 in3/rev] Standard
160÷130
to 130 cm3/rev [7.930 in3/rev] 160 cm3/rev [9.760 in3/rev]
– – – •
• : Required
– : Not required
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N6 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
5
Displacement
Minimum displacement limitation
055 075 108 160
From 12 cm3/rev [0.732 in3/rev] Standard
12÷42
to 42 cm3/rev [2.562 in3/rev] 30 cm3/rev [1.830 in3/rev] • – – –
From 16 cm3/rev [0.976 in3/rev] Standard
16÷56
to 56 cm3/rev [3.416 in3/rev] 40 cm3/rev [2.440 in3/rev]
– • – –
From 22 cm3/rev [1.342 in3/rev] Standard
22÷80
to 80 cm3/rev [4.880 in3/rev] 56 cm3/rev [3.416 in3/rev]
– – • –
From 32 cm3/rev [1.952 in3/rev] Standard
32÷112
to 112 cm3/rev [6.832 in3/rev] 80 cm3/rev [4.880 in3/rev]
– – – •
0 0 cm3/rev • • • •
• : Required
– : Not required
6
Displacement
Mount Flange
055 075 108 160
OL 2 Bolts Ø 160 mm [Ø 6.299 in] • – – –
OM 2 Bolts Ø 190 mm [Ø 7.48 in] – • – –
• : Available
– : Not Available
7
Displacement
Shaft end
055 075 108 160
SAI Splined W30x2x30x14 - DIN 5480 • – – –
SAM Splined W35x2x30x16 - DIN 5480 • – – –
• : Available
– : Not Available
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Ordering code N7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
8
Port cover
FM Metric End Main ports
9
Seal
V FKM
10
Control
RPE Working pressure control
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
11
Control
Control specification
RPE ROE 2EE 2EN 2IE 2IN REE RED RID
(1) REN (1) RIE RIN RPI ROI ROS RPS
1 Displacement setting
From max displacement to
min displacement (Vg max→ Vg min) – – • • • • • • • • • • – – – –
2 Displacement setting
From min displacement to
max displacement (Vg min→Vg max) • • – • – • – – • – – • • • • •
00 None – – – – – • – – – – – – – – – –
(1) Specify Pressure Setting values for Step 1 and Step 2 (Step1<Step2)
(**) Ø 0.4 mm [Ø 0.015 in] (standard) nozzle, provides a smooth control response (max-to-min and min-to-max), while Ø 0.5-0.7 mm [Ø 0.0196-0.027
in] (optional) nozzle, provides a faster reaction.
Warning:
The values showed are only valid in maximum and minimum displacement conditions of the respective displacement. For different values, verify the
possibility with the control diagrams present on the catalogue.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Ordering code N9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
12
Displacement
Valves
055 075 108 160
XXXX NONE • • • •
VCD1 VCD/1 Pilot assisted overcentre valve LM LM LM LM
• : Available
– : Not Available
The valves are available with ISO port cover only, please contact Technical department for SAE version.
(1) The LM - FM digit means that the valve is only available with LM - FM port cover.
13
Valve
Valves feature
XXXX VCD1 VCD2 VCR2 VCR4
010 Not Set - Aluminum [60÷350 bar [870 to 5075 psi] [Piloting ratio 6.2:1] – – – • –
013 Not Set 140÷350 bar [2030 to 5075 psi] [Piloting ratio 4.5:1] – – – – •
018 Not Set 140÷350 bar [1450 to 5800 psi] [Piloting ratio 8.5:1] – – – – •
• : Available
– : Not Available
Note:
Please contact Technical department for valve which requie specific setting.
For the feature see catalogue valves.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N10 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
14
Flushing valve
PR Arranged for Flushing Valve
15
Displacement
Serie feature
055 075 108 160
XX None • • • •
TS Prepared for tachometer sensor • • • •
TW Tachometer + sensor 2-channel-Hall effect PNP - 5V • • • •
TZ Tachometer + sensor 2-channel-Hall effect • • • •
• : Available
– : Not Available
16
Painting
XX Not Required
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Working pressure control Control RPE N11
The working pressure control allows to swivel the motor displacement from Vg min to Vg max when the operating pressure rises beyond
the preset operating pressure, so that the motor is at Vg min when min torque and max speed are required and at Vg max when max
torque and min speed are required. The operating pressure applies a force on the spool which is matched by an adjustable spring.
The motor keeps the Vg min until the operating pressure reaches the setting value (pressure setting). Once the preset pressure rises
beyond, the motor swivels from Vg min to Vg max. The swivel range is from Vg min to Vg max (displacement setting type 2 as per our ordering
code). Start of control adjustable between 100 and 400 bar [1450 and 5800 psi].
psi p bar
psi bar
6500 450
6000
400
B S1
5500
5000 350
B Y1
4500
300
Setting field
4000
Pressure
3500 250
3000
200
2500
150
2000
Vgmin
1500 100
1000 A Vgmax
50
500
0
0 0.2 0.4 0.6 0.8 1 1.2 A S2
Torque
T/Tat 400 bar [5946 psi]
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N12 Working pressure control with electrical override RPS
RPS control is a pressure related control which permits the changing of displacement Vg min to Vg max when working pressure exceeds
setting threshold, so that the motor works at Vg min when low torque and high speed are required and at Vgmax when high torque and
low speed are required. The motor stands at Vg min till working pressure reaches setting threshold. Δp of working pressure that allows
the changing of diaplacement from minimum to maximum is around 10 bar (such as RPE control).
This pressure related control can be overridden by an electrical signal; when solenoid is energized, the motor reaches maximum
displacement without stopping in an intermediate position.
Swivel range from Vg min to Vg max (assembly type 2 as per our ordering code).
Setting pressure range is 100-300 bar.
B F2 F1 Y1
Ma
Vgmin
X1
Mb Vgmax
A S1 S2
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Working pressure control with hydraulic override RPI N13
The hydraulic limiting device makes possible to reduce the pressure setting of RPE control by means of an external pilot pressure
applied at port X2. The RPE control pressure setting is reduced proportionally to the pilot pressure in the ratio of 1/17 (for each pilot
pressure bar, the preset operating pressure is reduced of 17 bar) [170 psi each 10 psi of pilot pressure]. Max permissible pilot pres-
sure at port X2 = 100 bar [1450 psi]. Example: preset operating pressure of RPE control = 300 bar [4350 psi]. By applying at port X2
a pilot pressure of 10 bar [145 psi] , the pressure setting comes to 130 bar [1885 psi] (300-(10x17)=130) (4350- (145X17)=1885).
Should it be required to swivel the motor to Vg max independently from the operating pressure, a pilot pressure of 20 bar [290 psi]
should be applied at port X2.
Swivel range from Vg min to Vg max (assembly type 2 as per our ordering code). Start of control adjustable between 100 and 400 bar
[1450 and 5800 psi].
p
psi
psi bar
bar
6500 450
B S1 X2
6000
400
5500 B Y1
5000 350
4500
300
4000
Setting field
Pressure
3500 250
3000
200
2500 Vgmin
150
2000
A Vgmax
1500 100
1000
50 A S2
500
0
0 0.2 0.4 0.6 0.8 1 1.2
Torque
T/Tat 400 bar [5946 psi]
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N14 Working pressure control - high pressure rise ROE
The “ROE” control allows a larger pressure range for displacement variation in comparison to “RPE” control. The increase of pres-
sure range for variation from Vg min to Vg max allows a smoother working of the motor during displacement variation. The “ROE” allows
the displacement variation with the pressure range show in the table.
Where:
• ∆p is the working pressure range that allows the displacement variation.
• Pmin is the minimum pressure at which displacement variation starting can be set.
• Pmax is the maximum pressure at which displacement variation starting can be set.
psi p bar
psi bar
6500 450
B S1
6000
400
MB Y1
5500
5000 350
∆p 100 bar [1450psi]
4500
300
Setting field
4000
Pressure
3500 250
3000
200 Vgmin
2500
150 MA Vgmax
2000
1500 100
1000 A S2
50
500
0
0 0.2 0.4 0.6 0.8 1 1.2
Torque
T/Tat 350 bar [50756 psi]
Warning: in case of displacement limitation, the control shall vary of a reduced ∆p with respect to its standard one. Please contact Dana for more info.
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Working pressure control Δp 100 bar with hydraulic override ROI N15
The hydraulic limiting device makes possible to reduce the pressure setting of ROE control by means of an external pilot pressure
applied at port X2. The ROE control pressure setting is reduced proportionally to the pilot pressure in the ratio of 1/17 (for each pilot
pressure bar, the preset operating pressure is reduced of 17 bar) [170 psi each 10 psi of pilot pressure]. Max permissible pilot pres-
sure at port X2 = 100 bar [1450 psi]. Example: preset operating pressure of ROE control = 300 bar [4350 psi]. By applying at port
X2 a pilot pressure of 10 bar [145 psi] , the pressure setting comes to 130 bar [1885 psi] (300-(10x17)=130) (4350- (145X17)=1885).
Should it be required to swivel the motor to Vg max independently from the operating pressure, a pilot pressure of 20 bar [290 psi]
should be applied at port X2.
Swivel range from Vg min to Vg max (assembly type 2 as per our ordering code). Start of control adjustable between 100 and 350 bar
[1450 and 5000 psi].
When ordering please clearly state:
Control pressure setting.
psi
p bar
psi bar
6500 450
6000
B S1 X2 400
5500
MB Y1 5000 350
Setting field
4000
Pressure
3500 250
3000
200
2500
Vgmin 150
2000
Vgmax 1500
MA 100
1000
50
500
A S2
0
0 0.2 0.4 0.6 0.8 1 1.2
Torque
T/Tat 350 bar [50756 psi]
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N16 Working pressure control Δp 100 bar with electrical override ROS
ROS control is a pressure related control which permits the changing of displacement Vg min to Vg max when working pressure exceeds
setting threshold, so that the motor works at Vg min when low torque and high speed are required and at Vg max when high torque and
low speed are required. The motor stands at Vg min till working pressure reaches setting threshold. Δp of working pressure that allows
the changing of diaplacement from minimum to maximum is 100 bar ( such as ROE control ).
This pressure related control can be overridden by an electrical signal; when solenoid is energized , the motor reaches maximum
displacement without stopping in an intermediate position.
Swivel range from Vg min to Vg max (assembly type 2 as per our ordering code).
Setting pressure range is 100-300 bar.
B F2 F1 Y1
Ma
Vgmin
X1
Mb Vgmax
A S1 S2
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Hydraulic two positions control 2IN N17
The hydraulic two positions control allows the displacement of the motor to be set to Vg max or Vg min by applying or not a pilot pressure
at port X2. The feed back spring is missing so Vg max or Vg min only can be set. Minimum required pilot pressure = 10 bar [145 psi] and
maximum permissible pressure at port X2=100 bar [1450 psi]. The swivel range is 1 (from Vg max to Vg min) or 2 (swivel range from Vg
min
to Vg max).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure is not guaranteed,
an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
X2
B S1
B Y1
Vgmin
Vgmax
A
A
S2
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N18 Hydraulic two positions control with pressure override 2IE
The 2IE control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same as
2IN control, the motor displacement is adjusted to Vg min when the pilot pressure applied at port X2. Minimum required pilot pressure
= 10 bar [145 psi] and maximum permissible pressure at port X2=100 bar [1450 psi]. If the operating pressure rises beyond the
pressure setting, the pressure limiting device the motor swivels out to Vg max. Swivel range is from Vg max to Vg min (displacement setting
1 per our ordering code).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure is not guaranteed,
an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
X2
B S1
B Y1
Vgmin
A Vgmax
A S2
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Electric two positions control 2EN N19
The electric two positions control allows the displacement of the motor to be set to Vg max or Vg min by switching an ON/OFF solenoid
valve. The feed back spring is missing so Vg max or Vg min only can be set. 12V DC and 24V DC ON/OFF solenoid are available. The
swivel range is 1 (from Vg max to Vg min) or 2 (swivel range from Vg min to Vg max).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure is not guaranteed,
an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
B S1
B Y1
Vgmin
Vgmax
A
A
S2
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N20 Hydraulic two positions control with pressure override 2EE
The 2EE control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same
as ‘2EN’ control, when solenoid valve is switched off the motor is at Vg max. The motor displacement is adjusted to Vg min when the
solenoid valve is switched on and if the operating pressure rises beyond the pressure setting, the pressure limiting device overrides
the electric two positions control and the motor swivels out to Vg max. Swivel range is from Vg max to Vg min (displacement setting 1 per
our ordering code).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure is not guaranteed,
an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
B S1
B Y1
Vgmin
A Vgmax
A
S2
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Hydraulic proportional control RIN N21
The hydraulic proportional control allows a stepless adjustment of the motor displacement proportionally to the pilot pressure ap-
plied at port X2. The pilot pressure applies a force on the spool and the motor swivels until a force balance on the arm is stored by
feed back spring. Therefore the motor displacement is adjusted in direct proportion with the pilot pressure. Usually the swivel range
is from Vg max to Vg min (displacement setting type 1 as per our ordering code) so that increasing the pilot pressure the motor swivels
towards Vg min, however, displacement setting type 2 (swivel range from Vg min to Vg max) is also available. Start of control, Setting range
from 5 bar [72.5 psi] to 20 bar [290 psi] around. Pilot pressure range 25 bar [362.5 psi]. Max permissible pilot pressure at port X2
= 100 bar [1450 psi].
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure is not guaranteed,
an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
RIN (1)
650 45
Pressure X 2
600
550
500 35
Setting field
Vg/V (%)
Vg/Vg max
g max
500
Px2 bar [psi]
450
400
350 25
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N22 Hydraulic proportional control with pressure override RIE
The RIE control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same as
RIN control, the motor displacement is adjusted to Vg min when the pilot pressure applied at port X2. If the operating pressure rises
beyond the pressure setting, the pressure limiting device the motor swivels out to Vg max. Swivel range is from Vg max to Vg min (displa-
cement setting 1 per our ordering code).
Start of control, Setting range from 5 bar [72.5 psi] to 20 bar [290 psi] around. Pilot pressure range 25 bar [362.5 psi]. Max permis-
sible pilot pressure at port X2 = 100 bar [1450 psi].
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure is not guaranteed,
an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
K1 X2
B
MB Y1
Vgmin
MA Vgmax X1
A
S2 S2
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Hydraulic proportional control with double step pressure override RID N23
The RID control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same as
RIN control, the motor displacement is adjusted to Vg min when the pilot pressure applied at port X2. If the operating pressure rises
beyond the pressure setting, the pressure limiting device the motor swivels out to Vg max. Swivel range is from Vg max to Vg min (displa-
cement setting 1 per our ordering code).
Applying a pressure to port X3, the setting of PE control can be overridden by a different value of pressure.
Setting range from 16 bar [232 psi] to 64 bar [928 psi] around. Start of control, Setting range from 5 bar [72.5 psi] to 20 bar [290 psi]
around. Pilot pressure range 25 bar [362.5 psi]. Max permissible pilot pressure at port X2 = 100 bar [1450 psi].
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure is not guaranteed,
an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
X2 F1 F3
B
MB Y1
X3
Vgmin
MA Vgmax X1
A S1 S2
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N24 Electric proportional control REN
The electrical proportional control allows stepless and programmable adjustment of the motor displacement proportionally to the
current strength supplied to a proportional solenoid valve available in 12V DC and 24V DC version and with connector DIN 43650 o
DEUTSCH. The proportional solenoid valve applies a force on the spool proportional to the current strength and the motor swivels
until a force balance is restored by a feed-back spring. To control the proportional solenoid valve a 24V DC (12V DC) supply is
required. Current range between 200 (400) and 600 (1200) mA approx. (with standard setting of Max and Min displacement). Max
permissible current = 800 (1600) mA. Usually the swivel range is from Vg max to Vg min (displacement setting type 1 as per our ordering
code) so that increasing the current strength the motor swivels towards Vg min, however displacement setting type 2 (swivels range
from Vg min to Vg max) is also available. The electronic devices are available to control the solenoid (they must be ordered separately).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure is not guaranteed,
an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Current
12V
I (mA)
12V
I (mA)
800 800
B Y1
600 600
400 400
200 200
500 500
24V
I (mA)
Current
I (mA)
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Electric proportional control with pressure override REE N25
The REE control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same
as REN control, when solenoid valve is switched off the motor is at Vg max. The proportional solenoid valve is available in 12V DC and
24V DC version and with connector DIN 43650 o DEUTSCH. The motor displacement is adjusted to Vg min when the solenoid valve
is switched on and if the operating pressure rises beyond the pressure setting, the pressure limiting device overrides the electric
two positions control and the motor swivels out to Vg max. Swivel range is from Vg max to Vg min (displacement setting 1 per our ordering
code).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure is not guaranteed,
an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
K1
B
MB Y1
Vgmin
MA Vgmax X1
A
S1 S2
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N26 Electric proportional control with double step pressure override RED
The RED control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same
as REN control, when solenoid valve is switched off the motor is at Vg max. The proportional solenoid valve is available in 12V DC and
24V DC version and with connector DIN 43650 o DEUTSCH. The motor displacement is adjusted to Vg min when the solenoid valve
is switched on and if the operating pressure rises beyond the pressure setting, the pressure limiting device overrides the electric
two positions control and the motor swivels out to Vg max. Swivel range is from Vg max to Vg min (displacement setting 1 per our ordering
code).
Applying a pressure to port X3, the setting of PE control can be overridden by a different value of pressure.
Setting range from 16 bar [232 psi] to 64 bar [928 psi] around.
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure is not guaranteed,
an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
B F1 F3
MB Y1
X3
Vgmin
MA Vgmax X1
A S1 S2
The relation between direction of rotation of shaft and direction of flow in SH7VR motor is shown in the picture below.
DC5A1G1_0000000 - 01/22
SH7VR-M/01
SH7VR 055 - Motor dimensions SH7VR 055 N27
206.3 [8.121]
SH7VR 055 Motor - Mounting112.5flange
[4.429]
2 Bolts (OL)
58.6 [2.31]
150 [5.91]
91 [3.58]
72 [2.834] 235 [9.25]
Y1 50 [1.97]
Min. stroke adjuster 200 [7.874]
M10 15 [0.59]
Depth 19 [0.75] Min. stroke adjuster
Depth.
A B
∅6.299]
S1
[2]
S2
∅104 [4.09]
∅132 [5.2]
163 [6.42]
50.8
Ø
∅160 h6 [
17
[
∅0
.6
11.9 [0.47]
11.9 [0.47]
7]
25.3 [0.996]
14°
43.3 [1.704]
OR 2-258 S2
Max. stroke adjuster 23.8 A
[0.93
7]
184.8 [7.275]
8 Shaft end
Splined Splined
SAI shaft SAM shaft
W30x2x30x14 - DIN 5480 W35x2x30x16 - DIN 5480
EP
Ø34.2 [1.35]
Ø29.6 [1.16]
M12
M10
28 [1.1]
22 [0.87]
32 [1.26]
92 [3.62]
24 [0.94]
92 [3.62]
132 [5.2]
127 [5]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N28 SH7VR 055 - Controls dimensions (displacement setting 1)
10 Control
2EE 2EN
96.6 [3.8]
175.7 [6.92]
Control starting
pressure adjustment
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
2IE 2IN
252.5 [9.94]
192.6 [7.58]
143.2 [5.64]
143.2 [5.64]
96.6 [3.8]
96.6 [3.8]
175.7 [6.92]
175.7 [6.92]
Control starting
pressure adjustment
X2 X2
67 [2.64] 108 [4.25] 67 [2.64] 58.5 [2.31]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
REE REN
Control starting
pressure adjustment
103.5 [4.07] 219.1 [8.63]
219.1 [8.63] 52.5 [2.07]
193 [7.6]
192.9 [7.59]
152.8 [6.01]
152.8 [6.02]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
SH7VR 055 - Controls dimensions (displacement setting 1) N29
10 Control
RIE RIN
Control starting 206.9 [8.15]
pressure adjustment
206.3 [8.12] 103.5 [4.07] 186 [7.32]
152.8 [6.01]
111.5 [4.39]
122.8 [4.83]
152.8 [6.02]
122.8 [4.83]
111.7 [4.4]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
RID RED
129.5 [5.1]
206.3 [8.12] X3 129.5 [5.1] 219.1 [8.63] 52.5 [2.07]
185.1 [7.29] 52.5 [2.07] X3
X2
192.9 [7.59]
152.8 [6.02]
92.6 [3.64]
122.8 [4.83]
111.7 [4.4]
152.8 [6.02]
92.6 [3.64]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N30 SH7VR 055 - Controls dimensions (displacement setting 2)
10 Control
RPE 2EN
58.5 [2.3] 130 [5.12]
187.5 [7.38]
192.6 [7.58]
146.8 [5.78]
123.2 [4.85]
175.7 [6.92]
96.6 [3.8]
Control starting
pressure adjustment
2IN REN
237.5 [9.35]
58.5 [2.3] 67 [2.64]
187.5 [7.38]
X2
102.8 [4.05]
146.8 [5.78]
258.6 [10.18]
123.2 [4.85]
88.7 [3.49]
RIN ROE
223.5 [8.8]
237.5 [9.35]
186.4 [7.34]
180.4 [7.1]
96.6 [3.8]
185.5 [7.31]
102.8 [4.05]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
SH7VR 055 - Controls dimensions (displacement setting 2) N31
10 Control
RPI ROI
96.1 [3.78]
96.1 [3.78]
223.5 [8.8] 223.5 [8.8]
185.6 [7.31]
180.3 [7.1]
180.3 [7.1]
185.6 [7.31]
51.5 [2.03] 50.3 [1.98] 51.5 [2.03] 50.3 [1.98]
111.9 [4.4] 111.9 [4.4]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
ROS RPS
102.8 [4.05]
258.6 [10.18]
258.6 [10.18]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N32 SH7VR 075 - Motor dimensions SH7VR 075
237.2 [9.34]
194.3 [7.65]
121.4 [4.78]
]
[2.25
B
]
A
0.0024
∅143 [ ∅5.63]
57.15
°
14
S2 S1
0
200 [7.87]
[ ∅7.48
Ø
21
[
11.7 [0.46]
11.7 [0.46]
Ø
-0.06
0.
27.8 [1.09]
83
45.9 [1.81]
∅116 [ ∅4.57]
A
0
]
Y1
∅190
OR 2-262 S2
Min. stroke adjuster
27.76
[1.09
3]
Max. stroke adjuster F1 F2
8 Shaft end
Splined
SAO shaft
28 [1.10]
33.6 [1.32]
110.5 [4.35]
151 [5.945]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
SH7VR 075 - Controls dimensions (displacement setting 1) N33
10 Control
2EE 2EN
205.6 [8.09]
205.6 [8.09]
188.1 [7.41]
110.2 [4.34]
188.1 [7.41]
110.2 [4.34]
Control starting
pressure adjustment
130 [5.12] 130 [5.12] 58.5 [2.3]
110 [4.33]
2IE 2IN
205.6 [8.09]
205.6 [8.09]
149.9 [5.9]
110.2 [4.34]
149.9 [5.9]
188.1 [7.41]
188.1 [7.41]
110.2 [4.34]
Control starting
pressure adjustment X2
X2
67 [2.64] 67 [2.64] 58.5 [2.3]
110 [4.33]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
REE REN
194.6 [7.66]
171.3 [6.74]
171 [6.73]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N34 SH7VR 075 - Controls dimensions (displacement setting 1)
10 Control
RIE RIN
219.7 [8.65]
219.7 [8.65]
190.2 [7.49]
190.2 [7.49]
X2
X2
125.4 [4.94]
171.2 [6.74]
116.7 [4.59]
125.4 [4.94]
116.7 [4.59]
171 [6.73]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
RID RED
125 [4.92]
95.3 [3.75]
223.5 [8.8] X3
95.3 [3.75]
219.7 [8.65]
X3 125 [4.92]
190.2 [7.49]
194.6 [7.66]
X2
171 [6.73]
116.7 [4.59]
125.4 [4.94]
171 [6.73]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
SH7VR 075 - Controls dimensions (displacement setting 2) N35
10 Control
RPE 2EN
166 [6.53]
130.2 [5.13]
110.2 [4.34]
Control starting
pressure adjustment
55.2 [2.17]
110 [4.33]
2IN REN
X2
102.4 [4.03]
166.1 [6.54]
130.2 [5.13]
265.7 [10.46]
87.6 [3.45]
RIN ROE
227.5 [8.96]
227.5 [8.96]
186.1 [7.32]
102.6 [4.04]
190.5 [7.5]
102.5 [4.03]
195.7 [7.71]
X2
114.7 [4.52]
57 [2.24] 45.8 [1.8]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N36 SH7VR 075 - Controls dimensions (displacement setting 2)
10 Control
RPI ROI
227.5 [8.96]
227.5 [8.96]
102.5 [4.03]
195.7 [7.71]
190.7 [7.51]
102.5 [4.03]
195.7 [7.71]
190.7 [7.51]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
ROS RPS
102.4 [4.03]
265.7 [10.46]
265.7 [10.46]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
SH7VR 108 - Motor dimensions SH7VR 108 N37
Depth 26 [1.02]
15 [0.59]
S1
-0.0011]
Y1
]
[2.25
0
S2
[∅7.874
S1 °
57.15
∅168 [ ∅6.61] 14
∅132 [ ∅5.2]
214.2 [8.43]
A B
Ø2
-0.029
1 [ Ø
0
0.8
3]
∅ 200
7.1 [0.279]
7.1 [0.279]
33.9 [1.335]
Min. stroke adjuster
52.3 [2.059]
OR 2-264 B
Max. stroke adjuster
82 [3.228]
27.76
[1.09
3]
8 Shaft end
Splined
SAO shaft
28 [1.1]
35 [1.38]
122.8 [4.83]
167.8 [6.61]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N38 SH7VR 108 - Controls dimensions (displacement setting 1)
10 Control
2EE 2EN
122.5 [4.82]
204.8 [8.06]
122.5 [4.82]
204.8 [8.06]
Control starting
pressure adjustment
2IE 2IN
220.2 [8.67]
220.2 [8.67]
173 [6.81]
122.5 [4.82]
204.8 [8.06]
173 [6.81]
122.5 [4.82]
204.8 [8.06]
Control starting
pressure adjustment
X2 X2
106 [4.17] 71 [2.8] 54.5 [2.15]
71 [2.8]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
REE REN
Control starting
pressure adjustment 261.2 [10.28] 43.8 [1.72] 59.5 [2.34]
261.2 [10.28] 99 [3.9] 59.5 [2.34]
202.4 [7.97]
202.4 [7.97]
183.9 [7.24]
183.9 [7.24]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
SH7VR 108 - Controls dimensions (displacement setting 1) N39
10 Control
RIE RIN
Control starting
257.5 [10.14] pressure adjustment 58.5 [2.3] 256 [10.08]
228.4 [8.99] 99 [3.9] 228.4 [8.99]
X2 43.8 [1.72] 58.5 [2.3]
X2
140.3 [5.52]
140.3 [5.52]
127.1 [5]
127.1 [5]
183.9 [7.24]
183.9 [7.24]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
RID RED
58.5 [2.3] 261.2 [10.28] 125 [4.92] 59.5 [2.34]
257.5 [10.14] X3 X3
228.4 [8.99] 125 [4.92]
X2
202.4 [7.97]
140.3 [5.52]
127.1 [5]
183.9 [7.24]
183.9 [7.24]
105.8 [4.17]
105.8 [4.17]
X2: Piloting port - 1/4 G (BSPP) X3: Double step piloting port - 1/4 G (BSPP)
X3: Double step piloting port - 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N40 SH7VR 108 - Controls dimensions (displacement setting 2)
10 Control
RPE 2EN
137.6 [5.42]
183.9 [7.24]
122.5 [4.82]
204.8 [8.06]
Control starting
pressure adjustment
59.2 [2.33]
106 [4.17]
2IN REN
237 [9.33]
122.5 [4.82]
289.7 [11.41]
183.9 [7.24]
103 [4.09]
RIN ROE
236.8 [9.32] 236.8 [9.32]
122.5 [4.82]
214.4 [8.44]
122.5 [4.82]
219.9 [8.66]
219.3 [8.63]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
SH7VR 108 - Controls dimensions (displacement setting 2) N41
10 Control
RPI ROI
122.5 [4.82]
122.5 [4.82]
214.4 [8.44]
214.4 [8.44]
219.3 [8.63]
219.3 [8.63]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
ROS RPS
237 [9.33]
237 [9.33]
122.5 [4.82]
289.7 [11.41]
122.5 [4.82]
289.7 [11.41]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N42 SH7VR 160 - Motor dimensions SH7VR 160
167.8 [6.606]
67 [2.638]
25 [0.98]
286 [11.26]
122 [4.8]
Min. stroke adjuster 250 [9.842]
92 [3.622]
S1
73 [2.87]
∅150 [ ∅5.91]
∅190 [ ∅7.48]
210 [8.27]
S1 S2 A
Ø2
∅ 200 +0
1
13.1 [0.516]
[ Ø
A B
14°
38.2 [1.503]
0 .8
48.1 [1.894]
3]
Y1 OR 2-264
5]
[2.62
15 [0.59]
66.68
100 [3.94] 31.75
100 [3.94] Max. stroke adjuster [1.25
]
207.6 [8.173]
8 Shaft end
Splined
SAR shaft
44 [1.73]
36 [1.42]
12 [0.472]
M16
Ø17 [0.67]
123 [4.843]
178 [7.01]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
SH7VR 160 - Controls dimensions (displacement setting 1) N43
10 Control
2EE 2EN
229.2 [9.02]
229.2 [9.02]
133.2 [5.24]
133.2 [5.24]
214.2 [8.43]
214.2 [8.43]
Control starting
pressure adjustment
137 [5.39]
103 [4.06] 137 [5.39] 51.5 [2.03]
2IE 2IN
229.2 [9.02]
229.2 [9.02]
184.8 [7.28]
133.2 [5.24]
214.2 [8.43]
184.8 [7.28]
133.2 [5.24]
214.2 [8.43]
Control starting
pressure adjustment
X2 103 [4.06] X2
74 [2.91] 74 [2.91] 51.5 [2.03]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
REE REN
100 [3.94]
Control starting 59.5 [2.34]
66 [2.6]
280.8 [11.06] pressure adjustment 280.8 [11.06] 66 [2.6]
206.2 [8.12]
206.2 [8.12]
192.1 [7.56]
192.1 [7.56]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N44 SH7VR 160 - Controls dimensions (displacement setting 1)
10 Control
RIE RIN
271.3 [10.68]
100 [3.94]
271.3 [10.68] 248.1 [9.77]
41 [1.61] 66 [2.6]
248.1 [9.77] Control starting X2
66 [2.6]
X2 pressure adjustment
141.5 [5.57]
141.5 [5.57]
192.1 [7.56]
130.9 [5.15]
192.1 [7.56]
130.9 [5.15]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
RID RED
206.2 [8.12]
141.5 [5.57]
111.4 [4.39]
192.1 [7.56]
192.1 [7.56]
111.4 [4.39]
130.9 [5.15]
X2: Piloting port - 1/4 G (BSPP) X3: Double step piloting port - 1/4 G (BSPP)
X3: Double step piloting port - 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
SH7VR-M/01
SH7VR 160 - Controls dimensions (displacement setting 2) N45
10 Control
RPE 2EN
229.2 [9.02]
140.1 [5.51]
133.2 [5.24]
214.2 [8.43]
Control starting
pressure adjustment
192.1 [7.56]
103 [4.06]
62.2 [2.45]
2IN REN
X2
140.1 [5.51]
119.2 [4.69]
108.2 [4.26]
192.1 [7.56]
300.5 [11.83]
66 [2.6] 45 [1.77]
X2: Piloting port - 1/4 G (BSPP)
RIN ROE
249.2 [9.81]
133.2 [5.24]
119.2 [4.69]
225.2 [8.87]
230.6 [9.08]
133.2 [5.24]
230.1 [9.06]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N46 SH7VR 160 - Controls dimensions (displacement setting 2)
10 Control
RPI ROI
249.2 [9.81]
249.2 [9.81]
133.2 [5.24]
133.2 [5.24]
230.1 [9.06]
225.2 [8.87]
230.1 [9.06]
225.2 [8.87]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
ROS RPS
249.2 [9.81] 249.2 [9.81]
119.2 [4.69]
119.2 [4.69]
300.5 [11.83]
300.5 [11.83]
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Other caratteristics N47
14 Flushing valve
For closed circuit operation, the motors can be equipped with built in flushing valve.
B X2
B Y1
Vgmin
A Vgmax
A S1 S2
B X2
B Y1
Vgmin
A Vgmax
A S1 S2
DC5A1G1_0000000 - 01/22
SH7VR-M/01
N48 Other caratteristics
14 Flushing valve
B S1
Y1
SH7VR SH7VR
Vgmin
055 075
Vgmax
A mm [in] 214 [8.42] 250 [9.84]
A S1 S2
DC5A1G1_0000000 - 01/22
SH7VR-M/01
Tachometer N49
TS - TW - TZ
Size
SH7VR 055 SH7VR 075 SH7VR 108 SH7VR 160
mm 84.2 88 96.2 103.8
A
[inch] [3.3] [3.46] [3.787] [4.086]
mm 23.5 23 25 29.4
B
[inch] [0.925] [0.906] [0.984] [1.157]
TW TZ
2-Channel differential-hall effect operating principle (1 square 2-Channel differential-hall effect operating principle Sensor
wave -1 digital for direction of rotation) Output signal PNP with dual-channel output (90°)
Power supply 4.5-16 VDC Power supply 8-32 VDC
Frequency 0 - 20.000 Hz Frequency 0-20.000 Hz
Operating temperature -40°C - +110°C Operating temperature -40°C +125°C
Degree of protection IP67
Sensor connector Deutsch DT04-4P
Electromagnetic compatibility according to EN 60947-5-2
Resistence to schock and vibration in accordance with IEC
68-2-17 IEC 68-2-6
Size
SH7VR 055 SH7VR 075 SH7VR 108 SH7VR 160
DC5A1G1_0000000 - 01/22
SH7VR-M/01
DC5A1G1_0000000 - 01/22
SH9V - Variable displacement axial piston motors for open and closed circuit O1
Indice
SH9V 085 85.3 [5.203] 341 [90.02] 430 [6235] 480 [6960]
SH9V 115 115.7 [7.05] 411 [108.5] 430 [6235] 480 [6960]
SH9V 165 166.2 [10.13] 515 [135.96] 430 [6235] 480 [6960]
SH9V 215 216 [13.176] 627 [165.63] 430 [6235] 480 [6960]
H9V series are a family of variable displacement motors, bent axis piston design for operation in both open and closed circuit. The
proven design incorporating the lens shape valve plate, the high quality components and manufacturing techniques make able the
SH9V series motors to provide up to 430 bar [6235 psi] ontinuous and 480 bar [6960 psi] peak performance.
Fully laboratory tested and field proven, these motors provide maximum efficiency and long life even at very bad filtering conditions.
Heavy duty bearings permit high radial and axial loads. Versatile design includes a variety of control and shaft ends that will adapt
the SH9V series motors to any application both industrial and mobile.
DC5A1G1_0000000 - 01/22
SH9V-M/01
O2 General information - Features
Simbology:
N/bar l/min
C [lbf/psi]
Load qmax [U.S. gpm]
Maximum flow
N l/min
Fax max [lbf]
Axial pushing load qd [U.S. gpm]
External drain flow
N Nm/bar
Fax max [lbf]
Axial pulling load Tk [lbf.ft/psi]
Torque costant
N Nm
Fq [lbf]
Radial load Tnom [lbf.ft]
Maximum torque at pressure cont.
N Nm
Fq max [lbf]
Maximum permissible radial load Tmax [lbf.ft]
Maximum torque at pressure peak
kg·m2 cm3/rev
J [lbf·ft2]
Moment of inertia Vg [in3/rev]
Displacement
kg kW
m [lbs]
Weight Pmax [hp]
Maximum power at pnom
Hydraulic fluids:
Use fluids with mineral oil basis and anticorrosive, antioxidant and wear preventing addition agents (HL or HM). Viscosity range
at operating temperature must be of 15÷40 cSt. For short periods and upon cold start, a max. viscosity of 800 cSt is allowed.
Viscosities less then 10 cSt are not allowed. A viscosity range of 10÷15 cSt is allowed for extreme operating conditions and for short
periods only. For further information see at Fluids and filtering section.
Temperature ranges:
The operating temperature of the oil must be within -25ºC ÷ 115ºC [-13ºF ÷ 239ºF]. The running of the unit with oil temperature higher
than 115ºC [239°F] or lower than -25ºC [-13°F] is not allowed. For further information see at Fluids and filtering section
Filtering:
A correct filtering helps to extend the service life of axial piston units. In order to ensure a correct functioning of the unit, the max.
permissible contamination class is 21/19/16 according to ISO 4406:1999. For further details see at Fluids and filtration section.
Operating pressure:
The maximum permissible pressure on pressure ports is 430 bar [6235 psi] continuous and 480 bar [6960 psi] peak. It two motors
are connected in series, total pressure has to be limited to following values: P1+P2 700 bar max. [10150 psi max].
P1 P2 P3
DC5A1G1_0000000 - 01/22
SH9V-M/01
General information - Features O3
Seals:
Seals used on standard SH9V series axial piston motors are of FKM seals (Fluoroelastomer - Viton®). In case of use of use special
fluids, contact Dana.
Port plates:
The SH9V motor port plate has inlet and outlet ports, both lateral (LM-LS cover) and frontal (FM-FS cover). Unused ports are plugged
with blind flanges. The kind of ports to be used must be specified when ordering.
Unit identification:
The SH9V motors compared to SH7V motors can be regognized by an identification mark on the topo of the shaft.
Figura 1 Figura 2
Picture 1 Picture 2
Flushing valve:
The motors can be equipped with built in flushing valve for closed circuit operation.
Installation:
The motors can be installed in every position or direction. These axial piston units have separate ports and drain chambers and so
must be always drained. Installation of the unit with shaft in vertical position and above the tank involves some limitations. For further
details see at General installation guidelines
DC5A1G1_0000000 - 01/22
SH9V-M/01
O4 Technical data
Size
061 085 115 165 215
cm3/rev 62 85.3 115.7 166.2 216
Max. Displacement Vg [in3/rev] [3.78] [5.203] [7.05] [10.13] [13.176]
cm3/rev 30 40 56 80 108
Min. Displacement Vg min [in3/rev] [1.83] [2.44] [3.416] [4.88] [6.59]
cm3/rev 12 17 23 33 43
Displacement minimum possible Vg min [in3/rev] [0.73] [1.03] [1.403] [2.01] [2.62]
cm3/rev 0 0 0 0 0
Displacement Optional Vg o [in3/rev] [0] [0] [0] [0] [0]
bar 430 430 430 430 430
Max. Press. cont. pnom [psi] [6235] [6235] [6235] [6235] [6235]
bar 480 480 480 480 480
Max. Press. peak pmax [psi] [6960] [6960] [6960] [6960] [6960]
l/min 276 341 411 515 627
Max. flow qmax [U.S.gpm] [72.86] [90.02] [108.5] [135.96] [165.63]
Max. speed at Vgmax and qmax n0 max rpm 4450 4000 3550 3100 2900
Max. speed at Vg<Vgmax(2) n0 max lim rpm 7000 6150 5600 5000 4600
Max. speed at Vg0 n0 max lim rpm 8350 7350 6300 5500 5100
(Theorical values, without considering ηhm and ηv; approximate values). Peak operations must not excide 1% of every minute. Avoid continuously
working at simultaneusly maximum pressure and maximum speed.
Notes:
(1) Maximum and minimum displacement can be changed with continuity. When ordering state Vgmax and Vgmin required.
(2) Determination of admissible speed nmax value can be increased by reducing motor maximum displacement. To determine the relationship
beetwen Vgmax and nmax use the right side chart. Motor maximum admissible speed is nmax lim.
(3) Approximate values.
(4) Maximum value at 250 bar [3625 psi] with mineral oil at 45ºC [113°F] and 35 cSt of viscosity.
Permessible
Velocità speed speed
ammissibile/Permessible
1.0
(Vg / Vgmax)
0.8
Cilindrata/Displacement
0.6
(Vg/Vg max)
Displscement
0.4
0.2
0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
Velocità/Speed
Speed(n/n(n/n
max)max)
DC5A1G1_0000000 - 01/22
SH9V-M/01
Ordering code O5
The following alphanumeric codes system has been developed to identify all of the configuration options for the SH11C motors.
Use the model code below to specify the desired features.
All alphanumeric digits system of the code must be present when ordering.
We advise to carefully read the catalogue before filling the ordering code.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Flanged valves
Flushing valve
Displacement
displacement
displacement
Mount flange
specification
Serie feature
Port cover
Maximum
Shaft end
limitation
limitation
Minimum
Painting
features
Control
Control
Series
Motor
Valve
Seal
SH9V M 061 62÷49 13÷42 OC S19 FM V RPE 00 XXXX 000 PR XX XX
1
Series
SH9V Variable displacement axial piston motor for open and closed circuit
2
Motore
M Motor
3
Displacement
061 62 cm3/rev [3.782 in3/rev]
4
Displacement
Maximum displacement limitation
061 085 115 165 215
From 62 cm3/rev [3.782 in3/rev] Standard
62÷49
to 49 cm3/rev [2.989 in3/rev] 62 cm3/rev [3.782 in3/rev] • – – – –
DC5A1G1_0000000 - 01/22
SH9V-M/01
O6 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
5
Displacement
Minimum displacement limitation
061 085 115 165 215
0 0 cm3/rev • • • • •
From 13 cm /rev [0.793 in /rev]
3 3
Standard
13÷42
to 42 cm3/rev [2.562 in3/rev] 30 cm3/rev [1.830 in3/rev] • – – – –
6
Displacement
Mount flange
061 085 115 165 215
OC ISO 4 Bolts Ø 125 mm [Ø 4.921 in] • – – – –
08 SAE-D 4 Bolts – – • • –
10 SAE-E 4 Bolts – – – – •
• Available
– Not available
DC5A1G1_0000000 - 01/22
SH9V-M/01
Ordering code O7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
7
Displacement
Shaft end
061 085 115 165 215
S19 Splined 15T - 8/16 DP – – – • •
S15 Splined 13T - 8/16 DP – – • • –
• Available
– Not available
8
Port cover
FM Metric End Main ports
Warning
Metric Ports (FM-LM) means both main ports and control ports
SAE Ports (FS-LS) means both main ports and control ports
DC5A1G1_0000000 - 01/22
SH9V-M/01
O8 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
9
Seal
V FKM
10
Control
DC5A1G1_0000000 - 01/22
SH9V-M/01
Ordering code O9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
11
Control
Caratteristica valvola
RPE ROE 2EE 2EN 2IE 2IN REE RED (1) REN RID (1) RIE RIN RPI ROI ROS RPS
00 None – – – – – – – – – – – – – – – –
100÷400 bar
[1430÷5802 psi] • – • – • – • • – • • – • – – –
Pressure
(*)
Setting (*)
100÷350 bar
[1430÷5076 psi]
– • – – – – – – – – – – – • • •
Start of control, 5-10-15-20 bar
(*)
Setting range (*) [72-145-218-290 psi]
– – – – – – – – – • • • – – – –
Δp Displacement 25 bar
(*)
change [363 psi]
– – – – – – – – – • • • – – – –
12 - Connector
12
DIN43650
– – • • – – • • • – – – – – • •
24 - Connector
24
DIN43650
– – • • – – • • • – – – – – • •
D2 12 - Deutsch DT04 – – • • – – • – • – – – – – • •
Voltage
D4 24 - Deutsch DT04 – – • • – – • – • – – – – – • •
12 V - ATEX T6
A2
(Solo 55 2EN)
– – – • – – – – • – – – – – – –
24 V - ATEX T6
A4
(Solo 55 2EN)
– – – • – – – – • – – – – – – –
With
04 Ø 0.4 mm [Ø 0.015 in] • – • • • • – – – – – – – – – –
Control Orifice
With
05 Control orifice (**) Ø 0.5 mm [Ø 0.0196 in] – • – – – – • • • • • • • • • •
Control Orifice
With
07 Ø 0.7 mm [Ø 0.027 in] • • • • • • • • • • • • • • • •
Control Orifice
Warning:
The values showed are only valid in maximum and minimum displacement conditions of the respective displacement. For
different values, verify the possibility with the control diagrams present on the catalogue.
(*) Supply the setting value
• Required
– Not available
(**) 0.4 mm [Ø 0.015 in] (standard) nozzle, provides a smooth control response (max-to-min and min-to-max), while
Ø 0.5-0.7 mm [Ø 0.0196-0.027 in] (optional) nozzle, provides a faster reaction.
DC5A1G1_0000000 - 01/22
SH9V-M/01
O10 Ordering code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
12
Displacement
Valve
061 085 115 165 215
XXXX None • • • • •
VCD1 VCD/1 Pilot assisted overcentre valve LM LM LM LM LM
• Available
– Not available
The valves are available with ISO port cover only, please contact Technical department for SAE version
The LM - FM digit means that the valve is only available with LM - FM port cover.
13
Valve
Flanged valves features
XXXX VCD1 VCD2 VCR2 VCR4
002 Not Set 0÷350 bar [0 to 5075 psi][Piloting ratio 2.9:1] - Control of rotation CW – • – – –
006 Not Set 0÷350 bar [0 to 5075 psi][Piloting ratio 2.9:1] - Control of rotation CCW – • – – –
003 Not Set 250÷500 bar [3625 to 7250 psi][Piloting ratio 13:1] - Control of rotation CW – – • – –
007 Not Set 250÷500 bar [3625 to 7250 psi] [Piloting ratio 13:1] - Control of rotation CCW – – • – –
010 Not Set - Aluminum 60÷350 bar [870 to 5075 psi] [Piloting ratio 6.2:1] – – – • –
013 Not Set 140÷350 bar [2030 to 5075 psi] [Piloting ratio 4.5:1] – – – – •
• Available
– Not available
Please contact Technical department for valve which requie specific setting.
For the feature see catalogue valves.
14
Flushing valve
PR Arranged for Flushing Valve
DC5A1G1_0000000 - 01/22
SH9V-M/01
Ordering code O11
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
15
Displacement
Serie feature
061 085 115 165 215
XX None • • • • •
TC Tachometer + Sensor with cable • – – • (*) –
16
Painting
XX Not Required
DC5A1G1_0000000 - 01/22
SH9V-M/01
O12 Electric two positions control with pressure override 2EE
The 2EE control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same
as ‘2EN’ control, when solenoid valve is switched off the motor is at Vg max. The motor displacement is adjusted to Vg min when the
solenoid valve is switched on and if the operating pressure rises beyond the pressure setting, the pressure limiting device overrides
the electric two positions control and the motor swivels out to Vg max. Swivel range is from Vg max to Vg min (displacement setting 1 per
our ordering code).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size: Size:
061-085-115-165 215
Dimensioni: 061-085-115-165 Dimensioni: 215
Size: 061-085-115-165 Size: 215
F1 S1
B S1 B
B Y1
B Y1
Vg min
Vgmax
A Vg max A Vgmin
A S2 A S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
Electric two positions control 2EN O13
The electric two positions control allows the displacement of the motor to be set to Vg max or Vg min by switching an ON/OFF solenoid
valve. The feed back spring is missing so Vg max or Vg min only can be set. 12V DC and 24V DC ON/OFF solenoid are available. The
swivel range is 1 (from Vg max to Vg min) or 2 (swivel range from Vg min to Vg max).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size: Size:
Dimensioni: 215
Dimensioni: 061-085-115-165
061-085-115-165 Size: 215215
Size: 061-085-115-165
F1
B S1 X2 B S1
B Y1
B Y1
Vg min
Vgmax
A Vg max
A
Vgmin
S2 A S2
A
DC5A1G1_0000000 - 01/22
SH9V-M/01
O14 Hydraulic two positions control with pressure override 2IE
The 2IE control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same as
2IN control, the motor displacement is adjusted to Vg min when the pilot pressure applied at port X2. Minimum required pilot pressure
= 10 bar [145 psi] and maximum permissible pressure at port X2=100 bar [1450 psi]. If the operating pressure rises beyond the
pressure setting, the pressure limiting device the motor swivels out to Vg max. Swivel range is from Vg max to Vg min (displacement setting
1 per our ordering code).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size: Size:
061-085-115-165 215
F1 X2
B
S1 X2
B
S1
B Y1
B Y1
Vg min
Vgmax
A Vg max A
Vgmin
S2 A S2
A
DC5A1G1_0000000 - 01/22
SH9V-M/01
Hydraulic two positions control 2IN O15
The hydraulic two positions control allows the displacement of the motor to be set to Vgmax or Vgmin by applying or not a pilot
pressure at port X2. The feed back spring is missing so Vgmax or Vgmin only can be set. Minimum required pilot pressure = 10
bar [145 psi] and maximum permissible pressure at port X2=100 bar [1450 psi]. The swivel range is 1 (from Vgmax to Vgmin) or 2
(swivel range from Vgmin to Vgmax).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1
Size: 061-085-115-165
Dimensioni: Size:
Dimensioni: 215
Size:061-085-115-165
061-085-115-165 Size: 215 215
F1 X2
S1 X2
B B
S1
B Y1
B Y1
Vg min
Vgmax
A Vg max A
Vgmin
A S2
A S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
O16 Electric proportional control with pressure override REE
The REE control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same
as REN control, when solenoid valve is switched off the motor is at Vg max. The proportional solenoid valve is available in 12V DC and
24V DC version and with connector DIN 43650 o DEUTSCH. The motor displacement is adjusted to Vg min when the solenoid valve
is switched on and if the operating pressure rises beyond the pressure setting, the pressure limiting device overrides the electric
two positions control and the motor swivels out to Vg max. Swivel range is from Vg max to Vg min (displacement setting 1 per our ordering
code).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size: Size:
061-085-115-165 215
B K1 B F1
S1
MB Y1
B Y1
Vg min
Vgmax
MA Vg max X1
A Vgmin
A S1 S2 A S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
Electric proportional control with double step pressure override RED O17
The RED control version with the pressure override allows the motor to swivel to Vgmax when the pressure setting is reached. Same
as REN control, when solenoid valve is switched off the motor is at Vg max. The proportional solenoid valve is available in 12V DC and
24V DC version and with connector DIN 43650 o DEUTSCH. The motor displacement is adjusted to Vg min when the solenoid valve
is switched on and if the operating pressure rises beyond the pressure setting, the pressure limiting device overrides the electric
two positions control and the motor swivels out to Vg max. Swivel range is from Vg max to Vg min (displacement setting 1 per our ordering
code).
Applying a pressure to port X3, the setting of PE control can be overridden by a different value of pressure.
Setting range from 16 bar [232 psi] to 64 bar [928 psi] around.
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size: Size:
061-085-115-165 215
Dimensioni: 215
Dimensioni: 061-085-115-165 Size: 215
Size: 061-085-115-165
F1
B S1
B F1 F3
MB Y1
B Y1
X3
Vg min
Vgmax
MA Vg max X1
A Vgmin
A S2
X3
A S1 S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
O18 Electric proportional control REN
The electrical proportional control allows stepless and programmable adjustment of the motor displacement proportionally to the
current strength supplied to a proportional solenoid valve available in 12V DC and 24V DC version and with connector DIN 43650 o
DEUTSCH. The proportional solenoid valve applies a force on the spool proportional to the current strength and the motor swivels
until a force balance is restored by a feed-back spring. To control the proportional solenoid valve a 24V DC (12V DC) supply is
required. Current range between 200 (400) and 600 (1200) mA approx. (with standard setting of Max and Min displacement). Max
permissible current = 800 (1600) mA. Usually the swivel range is from Vg max to Vg min (displacement setting type
1 as per our ordering code) so that increasing the current strength
the motor swivels towards Vg min, however displacement setting type 2 (swivels range from Vg min to Vg max) is also available. The
electronic devices are available to control the solenoid (they must be ordered separately).
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size:
I REN 12V (1) I REN 12V (2)
061-085-115-165
085-115-165 mA REN 12V (1) mA REN 12V (2)
-165 B S1
1600
1600
1400
1400
B Y1 1200
1200
1000
Current
Current
12V
I (mA)
1000
800 12V
I (mA)
800
600
600
400
400
200
200
Vg min 0 0.2 0.4 0.6 0.8 1
0 0.2 0.4 0.6 0.8 1
Vg/Vg max
A Vg max Vg/Vg max (%) VVg/Vg max(%)
/Vg max
g
A S2
Size:
215
5 I
REN 24V (1) I
B F1 S1
mA REN 24V (1) REN 24V (2)
mA REN 24V (2)
800 800
B Y1 700 700
600 600
Current
500 500
I (mA)
24V
I (mA)
Current
400 24V
400
300 300
Vgmax 200 200
100 100
Vgmin
A
0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1
Vg/Vg max (%)
Vg/Vg max
VgVg/Vg max
/Vg max (%)
A S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
Hydraulic proportional control with pressure override RIE O19
The RIE control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same
as RIN control, the motor displacement is adjusted to Vg min when the pilot pressure applied at port X2. If the operating pressure
rises beyond the pressure setting, the pressure limiting device the motor swivels out to Vg max. Swivel range is from Vg max to Vg min
(displacement setting 1 per our ordering code).
Start of control, Setting range from 5 bar [72.5 psi] to 20 bar [290 psi] around. Pilot pressure range 25 bar [362.5 psi]. Max
permissible pilot pressure at port X2 = 100 bar [1450 psi].
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size: Size:
061-085-115-165 215
F1 X2
B K1 X2 B
S1
MB Y1
B Y1
Vg min
Vgmax
MA Vg max X1
A Vgmin
A S2
A S1 S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
O20 Hydraulic proportional control with double step pressure override RID
The RID control version with the pressure override allows the motor to swivel to Vg max when the pressure setting is reached. Same
as RIN control, the motor displacement is adjusted to Vg min when the pilot pressure applied at port X2. If the operating pressure
rises beyond the pressure setting, the pressure limiting device the motor swivels out to Vg max. Swivel range is from Vg max to Vg min
(displacement setting 1 per our ordering code).
Applying a pressure to port X3, the setting of PE control can be overridden by a different value of pressure.
Setting range from 16 bar [232 psi] to 64 bar [928 psi] around. Start of control, Setting range from 5 bar [72.5 psi] to 20 bar [290
psi] around. Pilot pressure range 25 bar [362.5 psi]. Max permissible pilot pressure at port X2 = 100 bar [1450 psi].
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size: Size:
Dimensioni: 061-085-115-165
061-085-115-165 215215
Dimensioni:
Size: 061-085-115-165 Size: 215
B F1 X2
B X2
F1 F3
S1
MB Y1
B Y1
X3
Vg min
Vgmax
MA Vg max X1
A Vgmin
A S2
S1 S2 X3
A
DC5A1G1_0000000 - 01/22
SH9V-M/01
Hydraulic proportional control RIN O21
The hydraulic proportional control allows a stepless adjustment of the motor displacement proportionally to the pilot pressure
applied at port X2. The pilot pressure applies a force on the spool and the motor swivels until a force balance on the arm is stored by
feed back spring. Therefore the motor displacement is adjusted in direct proportion with the pilot pressure. Usually the swivel range
is from Vg max to Vg min (displacement setting type 1 as per our ordering code) so that increasing the pilot pressure the motor swivels
towards Vg min, however, displacement setting type 2 (swivel range from Vg min to Vg max) is also available. Start of control, Setting range
from 5 bar [72.5 psi] to 20 bar [290 psi] around. Pilot pressure range 25 bar [362.5 psi]. Max permissible pilot pressure at port X2
= 100 bar [1450 psi].
Note:
For reliable control, an operating pressure of at least 20 bar [290 psi], is necessary at port A (B). If in the application this pressure
is not guaranteed, an auxiliary pressure of 20 bar [290 psi] is to be applied at port Y1.
Size:
61-085-115-165
115-165 061-085-115-165
B S1 X2 px2
RIN (1)
psi bar RIN (1)
B Y1
650 45
600
550
X2
500 35
Pressure
400
350 25
fieldfield
A Vg min 0
0 0.2 0.4 0.6 0.8 1
Setting
VVg/Vg
/Vg max (%)
Setting
A S2 g max
Size:
215
i: 215 px2
psi bar RIN (2)
F1 X2 RIN (2)
B
650 45
S1 600
Pressure X 2
550
B Y1 500 35
Px2 bar [psi]
450
400
350 25
300 Pilot pressure increase
250
200 15
150
100 5
50
0
Vgmax 0 0.2 Vg/Vg0.6
0.4 (%)
0.8 1
Setting field
max
A S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
O22 Working pressure control Control RPE
The working pressure control allows to swivel the motor displacement from Vg min to Vg max when the operating pressure rises beyond
the preset operating pressure, so that the motor is at Vg min when min torque and max speed are required and at Vg max when max
torque and min speed are required. The operating pressure applies a force on the spool which is matched by an adjustable spring.
The motor keeps the Vgmin until the operating pressure reaches the setting value (pressure setting). Once the preset pressure rises
beyond, the motor swivels from Vg min to Vg max. The swivel range is from Vg min to Vg max (displacement setting type 2 as per our ordering
code). Start of control adjustable between 100 and 400 bar [1450 and 5800 psi].
Size:
061 - 085 - 115 - 165
61-085-115-165
115-165
B S1
psi p bar
B Y1
psi bar
6500 450
6000
400
5500
5000 350
Vg min
4500
300
Pressure
A Vg max
Setting field
4000
3500 250
A S2
3000
200
2500
Size: 2000
150
215
oni: 215 1500 100
5 F1 S1 1000
B
50
500
B Y1
0
0 0.2 0.4 0.6 0.8 1 1.2
Torque
T/Tat 400 bar [5946 psi]
Vg min
A Vg max
A S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
Working pressure control with hydraulic override RPI O23
The hydraulic limiting device makes possible to reduce the pressure setting of RPE control by means of an external pilot pressure
applied at port X2. The RPE control pressure setting is reduced proportionally to the pilot pressure in the ratio of 1/17 (for each
pilot pressure bar, the preset operating pressure is reduced of 17 bar) [170 psi each 10 psi of pilot pressure]. Max permissible pilot
pressure at port X2 = 100 bar [1450 psi].
Example: preset operating pressure of RPE control = 300 bar [4350 psi]. By applying at port X2 a pilot pressure of 10 bar [145 psi]
, the pressure setting comes to 130 bar [1885 psi] (300-(10x17)=130) (4350- (145X17)=1885). Should it be required to swivel the
motor to Vg max independently from the operating pressure, a pilot pressure of 20 bar [290 psi] should be applied at port X2. Swivel
range from Vg min to Vg max (assembly type 2 as per our ordering code). Start of control adjustable between 100 and 400 bar [1450
and 5800 psi].
Size:
061-085-115-165
061 - 085 - 115 - 165
5-115-165
B S1 X2
B Y1
p
psi
psi bar
bar
6000
400 [5800] 400
5500
field field
Pressione/Pressure Torque bar/[psi]
4500
A Vg max 300 [4350] 300
taratura/Setting
4000
Campo diSetting
Pressure
1000
F1 S1 50 [725] 50
B 500
0 0
B Y1 0 0.2 0.4 0.6 0.8 1 1.2
X2 Torque
Coppia/Torque (T/Tat 400 bar [5946 psi])
0 0.2 T/T
0.4 0.6 0.8
at 400 bar [5946 psi]
1 1.2
Vgmin
A Vgmax
A S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
O24 Working pressure control with electrical override RPS
RPS control is a pressure related control which permits the changing of displacement Vg min to Vg max when working pressure exceeds
setting threshold, so that the motor works at Vg min when low torque and high speed are required and at Vg max when high torque and
low speed are required. The motor stands at Vg min till working pressure reaches setting threshold.
Δp of working pressure that allows the changing of diaplacement from minimum to maximum is around 10 bar (such as RPE control).
This pressure related control can be overridden by an electrical signal; when solenoid is energized , the motor reaches maximum
displacement without stopping in an intermediate position. Swivel range from Vg min to Vg max (assembly type 2 as per our ordering
code).
Setting pressure range is 100-300 bar.
Size: Size:
061 - 085 - 115 - 165 215
Dimensioni: 061-085-115-165 Dimensioni: 215
Size: 061-085-115-165 Size: 215
F2 F1 Y1 B F1 S1
B
Ma
B Y1
Vg min Vg min
X1
Mb Vg max
A Vg max
A S2
A S1 S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
Working pressure control - high pressure rise ROE O25
The “ROE” control allows a larger pressure range for displacement variation in comparison to “RPE” control. The increase of
pressure range for variation from Vgmin to Vgmax allows a smoother working of the motor during displacement variation. The “ROE”
allows the displacement variation with the pressure range show in the table.
Δp Pmin Pmax
bar [psi] bar [psi] bar [psi]
Where:
• ∆p is the working pressure range that allows the displacement variation.
• Pmin is the minimum pressure at which displacement variation starting can be set.
• Pmax is the maximum pressure at which displacement variation starting can be set.
Size:
061 - 085 - 115 - 165
1-085-115-165
15-165
B S1
MB Y1 p
psi bar
psi bar
450 [6525] 6500 450
6000
400 [5800] 400
5500
bar [1450psi]
field field
350 [5075] 5000 350
Vg min
Pressione/Pressure Torque bar/[psi]
di taratura/Setting
4500
300 [4350] 300
MA Vg max
∆p 1450 psi
4000
100 bar
Pressure
Campo Setting
∆p 100
250 [3625] 250
3500
A S2
∆p
200 [2900]
3000
200
Size: 2500
215 150 [2175]
2000
150
: 215 F1 S1
B 100 [1450] 1500 100
1000
50 [725] 50
B Y1 500
0 0
0 0.2 0.4 0.6 0.8 1 1.2
Torque
Coppia/Torque (T/Tat 350 bar [5075 psi])
T/Tat 400 bar [5946 psi]
0 0.2 0.4 0.6 0.8 1 1.2
Vgmin
A Vgmax
A S2
Warning:
in case of displacement limitation, the control shall vary of a reduced ∆p with respect to its standard one. Please contact Dana for
more info.
DC5A1G1_0000000 - 01/22
SH9V-M/01
O26 Working pressure control Δp 100 bar with hydraulic override ROI
The hydraulic limiting device makes possible to reduce the pressure setting of ROE control by means of an external pilot pressure
applied at port X2. The ROE control pressure setting is reduced proportionally to the pilot pressure in the ratio of 1/17 (for each
pilot pressure bar, the preset operating pressure is reduced of 17 bar) [170 psi each 10 psi of pilot pressure]. Max permissible pilot
pressure at port X2 = 100 bar [1450 psi].
Example: preset operating pressure of ROE control = 300 bar [4350 psi]. By applying at port X2 a pilot pressure of 10 bar [145 psi]
, the pressure setting comes to 130 bar [1885 psi] (300-(10x17)=130) (4350- (145X17)=1885). Should it be required to swivel the
motor to Vg max independently from the operating pressure, a pilot pressure of 20 bar [290 psi] should be applied at port X2.
Swivel range from Vg min to Vg max (assembly type 2 as per our ordering code). Start of control adjustable between 100 and 350 bar
[1450 and 5000 psi].
Size:
i: 061-085-115-165
061 - 085 - 115 - 165
85-115-165
X2
p
B S1 psi bar
psi bar
Mb Y1 6500 450
6000
400
5500
5000 350
Vg min
Setting field
3500 250
Pressure
A S2
3000
200
Size:
215 2500
150
2000
: 215
F1 S1 1500
B 100
1000
B Y1 50
X2 500
0
0 0.2 0.4 0.6 0.8 1 1.2
Torque
Vgmin
T/Tat 400 bar [5946 psi]
A Vgmax
A S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
Working pressure control Δp 100 bar with electrical override ROS O27
ROS control is a pressure related control which permits the changing of displacement Vg min to Vg max when working pressure exceeds
setting threshold, so that the motor works at Vg min when low torque and high speed are required and at Vg max when high torque and
low speed are required. The motor stands at Vg min till working pressure reaches setting threshold. Δp of working pressure that allows
the changing of diaplacement from minimum to maximum is 100 bar ( such as ROE control ).
This pressure related control can be overridden by an electrical signal; when solenoid is energized , the motor reaches maximum
displacement without stopping in an intermediate position. Swivel range from Vg min to Vg max (assembly type 2 as per our ordering
code).
Setting pressure range is 100-300 bar.
Size: Size:
061 - 085 - 115 - 165 215
Dimensioni: 215
Dimensioni: 061-085-115-165
Size: 215
Size: 061-085-115-165
F1
B F2 F1 Y1 B S1
Ma B Y1
Vg min
X1 Vgmin
Mb Vg max
A Vgmax
A S2
A S2
S1
DC5A1G1_0000000 - 01/22
SH9V-M/01
O28 SH9V 061 - Motor dimensions
252.4 [9.94]
172.4 [6.79]
149.9 [5.9]
74 [2.91]
77 [3.03]
72 [2.83] Ø1 ]
3 99
31 [1.22] [ ∅ 150 [5.9] .2
M10 0 ∅6
[
35.8 [1.41]
Depth 19 [0.74] 10 [0.39] S1 .51 0
] 6
73 [2.87]
Ø1
25.3 [1]
B
[2]
A
∅125 [ ∅4.921]
50.8
150 [5.9]
Y1
14°
A
C 23.8
S2 [0.93
15 [0.59] 7 ]
61.5 [2.42]
45°
45°
143.1 [5.64]
126.8 [4.99]
142.2 [5.6]
Max. stroke adjuster 151.3 [5.96]
214.6 [8.45]
290.3 [11.43]
150 [5.91] 196.5 [7.74]
Min. stroke adjuster
72 [2.83] 98 [3.86]
Ø1
4 146 [5.748] 5]
74 [2.91]
Y1 20 [0.79] .3 .3
3/8" - 16 UNC 2B [0. [6
56 . 2
Depth 21 [0.826] ] 61
43.3 [1.71]
12.7 [0.5] S1 Ø1
25.3 [1]
A B
[2]
146 [5.748]
∅127 [ ∅5]
50.8
14°
C 23.8
S2 [0.93
17 [0.67] 7]
82 [3.23]
91.2 [3.59]
45°
268.8 [10.58] A 0' 0'
45°
Max. stroke adjuster
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 061 - Shafts dimensions for mounting flange ISO 4 bolts (OC) O29
M SAI
7
ANALATO/SPLINED Shaft end SCANALATO/SPLINED
5x2x30x16 - DIN 5480 W30x2x30x14 - DIN 5480
Splined Splined
SAM shaft SAI shaft
ø34.5 [1.358]
ø29.6 [1.17]
Spline W35x2x30x16 - DIN 5480 Spline W30x2x30x14 - DIN 5480
M12
M10
28 [1.1] 22 [0.87]
32 [1.26] 24 [0.95]
32 [1.26]
32 [1.26]
67 [2.64]
72 [2.84]
NALATO/SPLINED
2/24 DP
Splined
S12 shaft
3/8” 16 UNC-2B
ø31.15 [1.226]
26.7 [1.05]
32 [1.26]
32 [1.26]
79.6 [3.14]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O30 SH9V 061 - Shafts dimensions for mounting flange SAE-C 4 bolts (O5)
ø29.6 [1.17]
Spline W35x2x30x16 - DIN 5480 Spline W30x2x30x14 - DIN 5480
M12
M10
28 [1.1] 22 [0.87]
32 [1.26] 24 [0.95]
8 [0.31] 8 [0.31]
48 [1.89] 43 [1.69]
ALATO/SPLINED
/24 DP
Splined
S12 shaft
ø31.15 [1.226]
3/8” 16 UNC-2B
26.7 [1.05]
32 [1.26]
8 [0.31]
55.6 [2.19]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 061 - Controls dimensions for mounting flange ISO 4 bolts (OC) (Displ. setting 1) O31
10 Control
175.7 [6.92]
175.7 [6.92]
102.8 [4.05]
102.8 [4.05]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
pressure adjustment
130.2 [5.13] 107.8 [4.24] 130.2 [5.13] 58.3 [2.29]
252.5 [9.94]
252.5 [9.94]
143.2 [5.64]
143.2 [5.64]
175.7 [6.92]
102.8 [4.05]
175.7 [6.92]
102.8 [4.05]
Taratura pressione
Control starting
inizio regolazione
pressure adjustment
Control starting
X2 X2
pressure adjustment
67 [2.64] 108 [4.25] 67 [2.64] 58.5 [2.3]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
REN Control
Regolatore REN RIN Regolatore RIN
Control
REN Control RIN Control
152.8 [6.01]
152.8 [6.01]
111.5 [4.39]
122.8 [4.83]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O32 SH9V 061 - Controls dimensions for mounting flange ISO 4 bolts (OC) (Displ. setting 1)
10 Control
Regolatore REE
Regolatore RIE
REE Control REE Control RIE Control RIE Control
152.8 [6.01]
152.8 [6.01]
111.7 [4.4]
122.8 [4.83]
X2: Piloting port - 1/4 G (BSPP)
Regolatore RED
RID Control Regolatore RID RED Control RED Control
RID Control
129.5 [5.1]
X3
129.5 [5.1] 279.1 [10.99] 52.5 [2.07]
266.2 [10.48] X3
245 [9.65] 52.5 [2.07]
X2
192.9 [7.59]
152.8 [6.01]
152.8 [6.01]
122.8 [4.83]
111.7 [4.4]
92.6 [3.64]
92.6 [3.64]
X2: Piloting port - 1/4 G (BSPP) X3: Double step piloting port - 1/4 G (BSPP)
X3: Double step piloting port - 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 061 - Controls dimensions for mounting flange ISO 4 bolts (OC) (Displ. setting 2) O33
10 Control
Regolatore 2EN
RPE Control Regolatore RPE 2EN 2EN Control
Control
RPE Control
146.8 [5.78]
175.7 [6.92]
102.8 [4.05]
123.3 [4.85]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
pressure adjustment
55.2 [2.17] 108 [4.25]
102.8 [4.05]
123.3 [4.85]
185.5 [7.31]
88.7 [3.49]
180.4 [7.1]
X2
172.5 [6.79]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
102.8 [4.05]
258.6 [10.18]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O34 SH9V 061 - Controls dimensions for mounting flange ISO 4 bolts (OC) (Displ. setting 2)
10 Control
Regolatore RPI
ROI Control Regolatore ROI
ROI Control
RPI Control
RPI Control
185.6 [7.31]
185.6 [7.31]
102.8 [4.05]
102.8 [4.05]
180.4 [7.1]
180.4 [7.1]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
102.8 [4.05]
102.8 [4.05]
258.6 [10.18]
258.6 [10.18]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 061 - Controls dimensions for mounting flange SAE-C 4 bolts (O5) (Displ. setting 1) O35
10 Control
175.7 [6.92]
102.8 [4.05]
102.8 [4.05]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
pressure adjustment
130.1 [5.12] 107.9 [4.25] 130.1 [5.12] 58.4 [2.3]
143.2 [5.64]
143.2 [5.637]
175.8 [6.92]
96.5 [3.8]
175.8 [6.92]
96.6 [3.8]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
X2 pressure adjustment X2
67.1 [2.64] 58.4 [2.3]
67 [2.64] 108 [4.25]
X2: Piloting port - 7/16” - 20 UNF X2: Piloting port - 7/16” - 20 UNF
122.8 [4.83]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O36 SH9V 061 - Controls dimensions for mounting flange SAE-C 4 bolts (O5) (Displ. setting 1)
10 Control
Regolatore REE
RIE Control Regolatore RIE REE Control REE Control
RIE Control
Taratura pressione
inizio regolazione
Taratura pressione
Control starting
inizio regolazione
Control starting pressure adjustment
Control adjustment
pressure starting 103.5 [4.07]
pressure adjustment 303.1 [11.93] 52.5 [2.07]
290.2 [11.43] 103.6 [4.08]
269 [10.59] 52.4 [2.06]
X2
192.9 [7.59]
152.8 [6.01]
152.7 [6.01]
111.7 [4.4]
122.8 [4.83]
Regolatore RED
RED Control
RID Control Regolatore RID
RID Control
RED Control
150.5 [5.92]
X3
303.1 [11.93] X3 52.5 [2.07]
290.2 [11.43] 150.6 [5.93]
269 [10.59] X2 52.4 [2.06]
192.9 [7.59]
152.8 [6.01]
152.7 [6.01]
111.7 [4.4]
92.6 [3.64]
122.8 [4.83]
92.6 [3.64]
X2: Piloting port - 7/16” - 20 UNF X3: Double step piloting port - 7/16” - 20 UNF
X3: Double step piloting port - 7/16” - 20 UNF
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 061 - Controls dimensions for mounting flange SAE-C 4 bolts (O5) (Displ. setting 2) O37
10 Control
276.5 [10.89]
306.8 [12.08]
175.8 [6.92]
102.8 [4.05]
102.8 [4.05]
258.6 [10.18]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
pressure adjustment
55.2 [2.17] 108 [4.25]
Regolatore 2IN
2IN Control
2IN Control RIN Control
Regolatore RIN
RIN Control
102.8 [4.05]
123.2 [4.85]
88.7 [3.49]
185.5 [7.31]
180.4 [7.1]
X2
196.5 [7.74]
X2: Piloting port - 7/16” - 20 UNF X2: Piloting port - 7/16” - 20 UNF
Regolatore ROE
Regolatore REN ROE Control
REN Control
REN Control ROE Control
306.7 [12.07]
306.8 [12.08]
102.8 [4.05]
185.5 [7.31]
102.8 [4.05]
258.6 [10.18]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O38 SH9V 061 - Controls dimensions for mounting flange SAE-C 4 bolts (O5) (Displ. setting 2)
10 Control
185.6 [7.31]
102.8 [4.05]
102.8 [4.05]
180.4 [7.1]
180.4 [7.1]
196.3 [7.73] 51.5 [2.03] 50.3 [1.98] 196.3 [7.73] 51.5 [2.03] 50.3 [1.98]
X2 X2
X2: Piloting port - 7/16” - 20 UNF X2: Piloting port - 7/16” - 20 UNF
102.8 [4.05]
102.8 [4.05]
258.6 [10.18]
258.6 [10.18]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 085 - Motor dimensions O39
277.1 [10.91]
192.9 [7.594]
Min. stroke adjuster
164 [6.46] 83.7 [3.295]
82 [3.228] 31 [1.22]
80.5 [3.17]
M12 7]
Depth 19 [0.74] . 08
Ø1
4
164 [6.46] Ø7
10 [0.39] [ Ø [
S1 0.5 8 0
5] Ø1
]
[2.25
A B
57.15
∅140 [5.511]
164 [6.46]
157.2 [6.19]
149.9 [5.9]
Y1
14°
C A
S2
14 [0.551]
73.5 [2.893]
27.8 [1.094]
80.9 [3.19]
38.8 [1.527]
27.76
[1.09 45°
145.8 [5.74]
3] 45°
Max. stroke adjuster
170.3 [6.7]
237.1 [9.334]
Depth 19 [0.74] S1 6
∅ 14.5 [
∅ 0.57] ∅1
A B
∅127 [ ∅5]
150 [5.91]
157.2 [6.19]
149.9 [5.9]
Y1
14°
C A
1]
A
30.5 [1.2] S2
[2.25
93 [3.661]
57.2
261.1 [10.279]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O40 SH9V 085 - Shafts dimensions for mounting flange ISO 4 bolts (OD)
7 Shaft end
AM SAO
SAM Splined
CANALATO/SPLINED
shaft SAO Splined
SCANALATO/SPLINED
shaft
W40x2x30x18 - DIN 5480
35x2x30x16 - DIN 5480
ø39.3 [1.55]
ø34.3 [1.35]
M12
M12
28 [1.1]
28 [1.1]
29 [1.14]
32 [1.26] 33.6 [1.32]
32 [1.26]
72 [2.84] 77 [3.03]
NALATO/SPLINED
12/24 DP S12 Splined
shaft
32 [1.26]
37.5 [1.48]
32 [1.26]
79.6 [3.14]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 085 - Shafts dimensions for mounting flange SAE-C 4 bolts (O5) O41
7 Shaft end
SAM SAO
SAM Splined
SCANALATO/SPLINED
shaft SAO Splined
SCANALATO/SPLINED
shaft
W40x2x30x18 - DIN 5480
W35x2x30x16 - DIN 5480
8 [0.31]
ø34.1 [1.34]
ø39.3 [1.55]
M12
M12
28 [1.1] 28 [1.1]
48 [1.89] 53 [2.09]
Splined
S12 shaft
2
ANALATO/SPLINED
12/24 DP
8 [0.31]
ø30.8 [1.21]
32 [1.26]
37.5 [1.48]
55.6 [2.19]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O42 SH9V 085 - Controls dimensions for mounting flange ISO 4 bolts (OC) (Displ. setting 1)
10 Control
Regolatore 2EN
2EN Control
110.2 [4.34]
188.1 [7.41]
188.1 [7.41]
110.2 [4.34]
Control starting
pressure adjustment 130 [5.12] 58.5 [2.3]
130 [5.12] 110 [4.33]
Regolatore 2IN
2IN Control
277.1 [10.91]
277.1 [10.91]
149.9 [5.9]
149.9 [5.9]
188.1 [7.41]
110.2 [4.34]
188.1 [7.41]
110.2 [4.34]
Control starting
X2 pressure adjustment X2
67 [2.64] 67 [2.64] 58.5 [2.3]
110 [4.33]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
REN Control
Regolatore REN RIN Control
Regolatore RIN
REN Control
RIN Control
160.4 [6.32]
116.7 [4.59]
125.4 [4.94]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 085 - Controls dimensions for mounting flange ISO 4 bolts (OD) (Displ. setting 1) O43
10 Control
Regolatore REE
Regolatore RIE REE Control
RIE Control RIE Control REE Control
302 [11.89]
298.2 [11.74]
268.7 [10.58]
X2
194.6 [7.66]
160.4 [6.32] 125.4 [4.94]
160.4 [6.32]
X2: Piloting port - 1/4 G (BSPP)
298.2 [11.74]
268.7 [10.58] X3
X2
194.6 [7.6]
160.4 [6.32]
160.4 [6.32]
116.7 [4.59]
125.4 [4.94]
95.3 [3.75]
X2: Piloting port - 1/4 G (BSPP) X3: Double step piloting port - 1/4 G (BSPP)
X3: Double step piloting port - 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
SH9V-M/01
O44 SH9V 085 - Controls dimensions for mounting flange ISO 4 bolts (OD) (Displ. setting 2)
10 Control
130.2 [5.13]
166 [6.53]
Control starting
pressure adjustment
55.2 [2.17]
110 [4.33]
102.6 [4.04]
87.6 [3.45]
186.1 [7.32]
190.5 [7.5]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
102.7 [4.04]
195.5 [7.7]
265.7 [10.46]
53 [2.09] 40 [1.57]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 085 - Controls dimensions for mounting flange ISO 4 bolts (OD) (Displ. setting 2) O45
10 Control
ROI Control
Regolatore ROI
RPI Control
Regolatore RPI
ROI Control RPI Control
102.7 [4.04]
102.7 [4.04]
190.5 [7.5]
195.5 [7.7]
190.5 [7.5]
195.5 [7.7]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
102.4 [4.03]
102.4 [4.03]
265.7 [10.46]
265.7 [10.46]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O46 SH9V 085 - Controls dimensions for mounting flange SAE-C 4 bolts (05) (Displ. setting 1)
10 Control
301.1 [11.85]
301.1 [11.85]
188.1 [7.41]
110.2 [4.34]
Control starting
110.2 [4.34]
188.1 [7.41]
pressure adjustment
130 [5.12]
110 [4.33]
130 [5.12] 58.5 [2.3]
Regolatore 2IN
2IE Control
149.9 [5.9]
149.9 [5.9]
110.5 [4.35]
187.8 [7.4]
110.5 [4.35]
187.8 [7.4]
Control starting
pressure adjustment
X2 X2
67 [2.64] 67 [2.64] 58.5 [2.3]
110 [4.33]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
Regolatore REN
RIN ControlRegolatore RIN REN ControlREN Control
RIN Control
160.4 [6.32]
160.4 [6.32]
125.4 [4.94]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 085 - Controls dimensions for mounting flange SAE-C 4 bolts (05) (Displ. setting 1) O47
10 Control
Regolatore REE
Regolatore RIE
RIE Control RIE Control REE ControlREE Control
194.6 [7.66]
160.4 [6.32] 125.4 [4.94]
117 [4.6]
160.4 [6.32]
X2: Piloting port - 7/16”-20 UNF
194.6 [7.66]
117 [4.6]
160.4 [6.32]
160.4 [6.32]
95.3 [3.75]
95.3 [3.75]
125.4 [4.94]
X2: Piloting port - 7/16”-20 UNF X3: Double step piloting port - 7/16”-20 UNF
X3: Double step piloting port - 7/16”-20 UNF
DC5A1G1_0000000 - 01/22
SH9V-M/01
O48 SH9V 085 - Controls dimensions for mounting flange SAE-C bolts (05) (Displ. setting 2)
10 Control
Regolatore 2EN
RPE Control 2EN 2EN Control
Control
166.1 [6.54]
130.2 [5.13]
110.5 [4.35]
187.8 [7.4]
55.2 [2.17]
110 [4.33]
185.8 [7.31]
87.6 [3.45]
102.6 [4.04]
190.5 [7.5]
X2 45.8 [1.8]
57 [2.24]
217.2 [8.55]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
102.7 [4.04]
195.4 [7.69]
265.7 [10.46]
53 [2.09] 40 [1.57]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 085 - Controls dimensions for mounting flange SAE-C 4 bolts (05) (Displ. setting 2) O49
10 Control
102.7 [4.04]
190.5 [7.5]
195.4 [7.69]
190.5 [7.5]
X2 X2
57 [2.24] 45.8 [1.8] 57 [2.24] 45.8 [1.8]
215.4 [8.48] 215.4 [8.48]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
330 [12.99]
330 [12.99]
102.4 [4.03]
102.4 [4.03]
265.7 [10.46]
265.7 [10.46]
53 [2.09] 40 [1.57]
53 [2.09] 40 [1.57]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O50 SH9V 115 - Motor dimensions
302.6 [11.913]
93 [3.66]
190 [7.48] ]
82 [3.23] 35.2 [1.38] .87
Ø7
M12 7.1 [0.28] S1 [
00
33.9 [1.33]
44.3 [1.74]
Depth 26 [1.02]
Ø2
97 [3.82]
∅160 [ ∅6.299]
14°
A B
190 [7.48]
7]
[ Ø0.6
Ø17
173,6 [6,83]
174,6 [6,87]
Y1
B
C
1]
S2
[2.25
17.9 [0.7]
95.5 [3.76]
57.2
27.8
Max. stroke adjuster [1.09 45°
173.6 [6.84] 4] 45°
198.6 [7.82]
271,1 [10,66]
335 [13.189]
200 [7.87] ]
82 [3.23] 13 [0.511]
.9 96
Ø8
7/16"-14 UNC 2B S1 [
8.5
44.4 [1.75]
97.2 [3.83]
Depth 26 [1.02] 2
Ø2
34 [1.34]
∅152.4 [ ∅6]
A B
200 [7.87]
14°
0.83]
Ø21 [ Ø
173,6 [6,83]
174,6 [6,87]
Y1 B
C
1]
S2
32.5 [1.28]
[2.25
127.5 [5.02]
57.2
27.8 45°
Max. stroke adjuster [1.09
] 45°
205.6 [8.1]
230.6 [9.08]
303,1 [11,93]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 115 - Shafts dimensions for mounting flange ISO 4 bolts (OE) O51
7 Shaft end
SAP
SA0
SAP Splined
SCANALATO/SPLINED
shaft SA0 Splined
SCANALATO/SPLINED shaft
W45x2x30x21 - DIN 5480
Spline W45x2x30x21 - DIN 5480
W40x2x30x18 - DIN 5480
Spline W40x2x30x18 - DIN 5480
42 [1.65]
35 [1.38]
36 [1.42]
28 [1.1]
12 [0.472]
9.5 [0.374]
ø17 [0.669]
M16
44.5 [1.75]
M12
ø13 [0.511]
39.3 [1.55]
40 [1.58]
40 [1.58]
50 [1.97]
45 [1.77]
Splined
15 S15 shaft
CANALATO/SPLINED
3T 8/16 DP
Spline 13T 8/16 DP
37.9 [1.49]
36 [1.42]
13 [0.511]
1/2”-20UNF
ø13 [0.511]
44.2 [1.74]
8 [0.314]
66.5 [2.62]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O52 SH9V 115 - Shafts dimensions for mounting flange SAE-D 4 bolts (08)
7 Shaft end
15
S15 Splined
shaft
CANALATO/SPLINED
3T 8/16 DP
Spline 13T 8/16 DP
37.9 [1.49]
36 [1.42]
13 [0.511]
1/2”-20UNF
ø13 [0.511]
44.2 [1.74]
8 [0.314]
66.5 [2.62]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 115 - Controls dimensions for mounting flange ISO 4 bolts (OE) (Displ. setting 1) O53
10 Control
Regolatore 2EN
2EN Control
122.5 [4.82]
122.5 [4.82]
204.8 [8.06]
204.8 [8.06]
Control starting
pressure adjustment
134 [5.28] 106 [4.17] 134 [5.28] 54.5 [2.15]
Regolatore 2IN
2IE Control 2IN Control 2IN Control
303 [11.93]
303 [11.93]
122.5 [4.82]
173 [6.81]
204.8 [8.06]
122.5 [4.82]
173 [6.81]
204.8 [8.06]
Control starting
pressure adjustment
X2 X2
71 [2.8] 71 [2.8] 54.5 [2.15]
106 [4.17]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
Taratura pressione
Control starting
inizio regolazione
pressure adjustment
Control starting
pressure adjustment 344 [13.54] 43.8 [1.72] 59.5 [2.34]
344 [13.54] 99 [3.9] 59.5 [2.34]
202.4 [7.97]
202.4 [7.97]
183.9 [7.24]
183.9 [7.24]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O54 SH9V 115 - Controls dimensions for mounting flange ISO 4 bolts (OE) (Displ. setting 1)
10 Control
Regolatore RIE Regolatore RIN
RIN Control
RIE Control RIE Control RIN Control
Taratura pressione
inizio regolazione
Controlstarting
Control starting
pressureadjustment
pressure adjustment 338.8 [13.34]
338.8 [13.34] 311.2 [12.25]
43.8 [1.72] 58.5 [2.3]
99 [3.9] 58.5 [2.3] X2
311.2 [12.25]
X2
140.3 [5.52]
127.1 [5.00]
140.3 [5.52]
127.1 [5.00]
183.9 [7.24]
183.9 [7.24]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
183.9 [7.24]
105.8 [4.17]
183.9 [7.24]
105.8 [4.17]
X2: Piloting port - 1/4 G (BSPP) X3: Double step piloting port - 1/4 G (BSPP)
X3: Double step piloting port - 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 115 - Controls dimensions for mounting flange ISO 4 bolts (OE) (Displ. setting 2) O55
10 Control
Regolatore 2EN
RPE Control 2EN Control 2EN Control
Regolatore RPE
RPE Control
137.6 [5.42]
183.9 [7.24]
122.5 [4.82]
204.8 [8.06]
Taratura pressione
inizio regolazione
Control starting
Control starting
pressure adjustment
59.2 [2.33] 139 [5.47] pressure adjustment
103.9 [4.09]
183.9 [7.24]
122.5 [4.82]
289.7 [11.41]
RIN Control
Regolatore RIN ROE Control Regolatore ROE
ROE Control
RIN Control
319.8 [12.59]
319.8 [12.59]
122.5 [4.82]
122.5 [4.82]
219.3 [8.63]
214.4 [8.44]
219.9 [8.66]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O56 SH9V 115 - Controls dimensions for mounting flange ISO 4 bolts (OE) (Displ. setting 2)
10 Control
Regolatore RPI
Regolatore ROI
ROI Control ROI Control RPI Control RPI Control
319.8 [12.59]
319.8 [12.59]
122.5 [4.82]
214.5 [8.44]
219.3 [8.63]
122.5 [4.82]
214.5 [8.44]
219.3 [8.63]
226.1 [8.9] X2
226.1 [8.9] 55 [2.17] 40 [1.57]
X2 55 [2.17] 40 [1.57]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
122.5 [4.82]
122.5 [4.82]
289.7 [11.41]
289.7 [11.41]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 115 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 1) O57
10 Control
122.5 [4.82]
204.8 [8.06]
122.5 [4.82]
204.8 [8.06]
Control starting
pressure adjustment
134 [5.28] 54.5 [2.15]
134 [5.28] 106 [4.17]
173.6 [6.83]
122.5 [4.82]
122.5 [4.82]
204.8 [8.06]
Control starting
pressure adjustment
X2 X2
71 [2.8] 71 [2.8] 54.5 [2.15]
106 [4.17]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
Regolatore REE
Regolatore REN
REE Control REE Control REN Control
REN Control
Taratura pressione
inizio regolazione
Control
Control starting
starting
pressure
pressure adjustment
adjustment 59.5 [2.34]
59.5 [2.34]
376 [14.8] 43.8 [1.72]
376 [14.8] 99 [3.9]
202.4 [7.97]
202.4 [7.97]
183.9 [7.24]
183.9 [7.24]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O58 SH9V 115 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 1)
10 Control
Taratura pressione
inizio regolazione
Controlstarting
Control starting
pressureadjustment
pressure adjustment
370.8 [14.6] 58.5 [2.3]
370.8 [14.6] 58.5 [2.3] 343.2 [13.51] 43.8 [1.72]
343.2 [13.51] X2 99 [3.9] X2
140.3 [5.52]
127.1 [5.00]
140.3 [5.52]
127.1 [5.00]
183.9 [7.24]
183.9 [7.24]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
59.5 [2.34]
376 [14.8] 146 [5.75]
370.8 [14.6] 58.5 [2.3] X3
X3
343.2 [13.51] 146 [5.75]
X2
202.4 [7.97]
140.3 [5.52]
127.1 [5.00]
183.9 [7.24]
183.9 [7.24]
105.8 [4.17]
105.8 [4.17]
X2: Piloting port - 7/16”-20 UNF X3: Double step piloting port - 7/16”-20 UNF
X3: Double step piloting port - 7/16”-20 UNF
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 115 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 2) O59
10 Control
Regolatore REN
REN Control
RPE Control 2EN Control
122.5 [4.82]
122.5 [4.82]
204.8 [8.06]
289.7 [11.41]
Control starting
pressure adjustment
59.2 [2.33]
106 [4.17]
58.5 [2.3] 43.8 [1.72]
341.9 [13.46]
299.8 [11.8] 51 [2.01] 71 [2.8] 351.8 [13.85]
X2
137.6 [5.42]
183.9 [7.24]
122.5 [4.82]
103.9 [4.09]
289.7 [11.41]
122.5 [4.82]
214.4 [8.44]
219.9 [8.66]
219.3 [8.63]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O60 SH9V 115 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 2)
10 Control
Regolatore RPI
Regolatore ROI
RPI Control
ROI Control ROI Control RPI Control
122.5 [4.82]
122.5 [4.82]
214.4 [8.44]
219.3 [8.63]
214.4 [8.44]
219.3 [8.63]
X2: Piloting port - 7/16”-20 UNF X2: Piloting port - 7/16”-20 UNF
122.5 [4.82]
122.5 [4.82]
289.7 [11.41]
289.7 [11.41]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 165 - Motor dimensions O61
312.3 [12.294]
39 [1.54]
105 [4.13]
92 [3.62] 99.5 [3.92]
Min. stroke adjuster 210 [8.27]
S1
M14
Depth 28 [1.09]
]
Ø8.82
n 180 [Ø7,08]
[
Ø224
A B
210 [8.27]
A
14°
108 [4,25]
182,2 [7,17]
184,9 [7,27]
Ø18
[
38,2 [1,50]
30 [1.18]
Ø0.7
48,1 [1,89]
1 ]
Y1 C
5]
29.5 [1.16] S2
[2,62
99.5 [3.92]
66,7
31.6 45°
Max. stroke adjuster
[1.24
4] 45°
189.7 [7.47]
214.8 [8.46]
290,6 [11,44]
344.3 [13.553]
282.8 [11.13]
173.5 [6.83] 200 [7.87]
Min. stroke adjuster
92 [3.62] S1
1/2"-13 UNC 2B
Depth 28 [1.09] 9 ]
Ø8.9
8 .5 [
Ø22
A
Ø152.4 [Ø6]
A B
200 [7.87]
14°
182,2 [7,17]
184,9 [7,27]
Ø20.5
38,2 [1,50]
48,1 [1,89]
[ Ø
0.81
]
Y1
32 [1.26] C
,625]
108 [4.25]
S2
[2
131,5 [5,17]
31.6
[1.24 45° 45°
221,7 [8,72] 4]
246,8 [9,71]
322,6 [12,70]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O62 SH9V 165 - Shafts dimensions for mounting flange ISO 4 bolts (OF)
7 Shaft end
Splined Splined
SAP shaft SAO SA0 shaft
ALATO/SPLINED SCANALATO/SPLINED
x30x21 - DIN 5480 Spline W45x2x30x21 - DIN 5480
W40x2x30x18 - DIN 5480
Spline W40x2x30x18 - DIN 5480
50 [1.97]
40 [1.57]
42 [1.65]
36 [1.42]
36 [1.42]
12 [0.472]
ø17 [0.669]
M16
M16
ø17 [0.669]
40 [1.58]
50 [1.97] 41 [1.61]
Splined
S19 shaft
NALATO/SPLINED
Spline 15T 8/16 DPD
/16 DPD
53 [2.09]
36 [1.42]
13 [0.511]
1/2”-20 UNF
ø13 [0.511]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 165 - Shafts dimensions for mounting flange SAE-D 4 bolts (08) O63
7 Shaft end
Splined Splined
S15 shaft S19 shaft
S19
SCANALATO/SPLINED
NALATO/SPLINED Splined 13T 8/16 DP
15T 8/16 DP
/16 DP Splined 15T 8/16 DP
53 [2.09]
55 [2.17]
36 [1.42]
36 [1.42]
13 [0.511]
13 [0.511]
1/2”-20 UNF
ø13 [0.511]
1/2”-20 UNF
ø13 [0.511]
8 [0.314]
75.5 [2.97]
68 [2.68] 8 [0.314]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O64 SH9V 165 - Controls dimensions for mounting flange ISO 4 bolts (OF) (Displ. setting 1)
10 Control
312.3 [12.29]
312.3 [12.29]
Control starting
pressure adjustment
133.2 [5.24]
133.2 [5.24]
213.8 [8.42]
213.8 [8.42]
103 [4.06] 51.5 [2.03] 137 [5.39]
137 [5.39]
240 [9.45]
187.6 [7.39]
133.1 [5.24]
187.6 [7.39]
213.8 [8.42]
213.8 [8.42]
Control starting
pressure adjustment
X2
74 [2.91] 103 [4.06] X2
74 [2.91] 51.5 [2.03]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
Control starting
pressure adjustment 100 [3.94] 66 [2.6]
363.8 [14.32]
206.2 [8.12]
192.1 [7.56]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 165 - Controls dimensions for mounting flange ISO 4 bolts (OF) (Displ. setting 1) O65
10 Control
143.7 [5.66]
143.7 [5.66]
192.1 [7.56]
130.9 [5.15]
130.9 [5.15]
192.1 [7.56]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
206.2 [8.12]
130.9 [5.15]
111.4 [4.39]
192.1 [7.56]
111.4 [4.39]
192.1 [7.56]
X2: Piloting port - 1/4 G (BSPP) X3: Double step piloting port - 1/4 G (BSPP)
X3: Double step piloting port - 1/4 G (BSPP)
DC5A1G1_0000000 - 01/22
SH9V-M/01
O66 SH9V 165 - Controls dimensions for mounting flange ISO 4 bolts (OF) (Displ. setting 2)
10 Control
Regolatore 2EN
RPE Control 2EN Control
2EN Control
Control starting
pressure adjustment 312.3 [12.29] 137 [5.39] 51.5 [2.03] 328.7 [12.94]
133.2 [5.24]
213.8 [8.42]
140 [5.51]
192.1 [7.56]
103 [4.06]
62.2 [2.45]
Regolatore REN
2IN Control Regolatore 2IN REN Control
REN Control
2IN Control
332.2 [13.08]
X2
140 [5.51]
119.2 [4.69]
300.5 [11.83]
108.9 [4.29]
192.1 [7.56]
66 [2.6] 45 [1.77]
X2: Piloting port - 1/4 G (BSPP)
Regolatore ROE
Regolatore RIN ROE Control
RIN Control
RIN Control
ROE Control
230.1 [9.06]
225.2 [8.87]
230.6 [9.08]
66 [2.6] 41 [1.61]
242.3 [9.54] X2 66 [2.6] 45 [1.77]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 165 - Controls dimensions for mounting flange ISO 4 bolts (OF) (Displ. setting 2) O67
10 Control
Regolatore ROI Regolatore RPI
ROI Control RPI Control
ROI Control RPI Control
133.2 [5.24]
133.2 [5.24]
225.2 [8.87]
230.1 [9.06]
225.2 [8.87]
230.1 [9.06]
X2: Piloting port - 1/4 G (BSPP) X2: Piloting port - 1/4 G (BSPP)
Regolatore RPS
ROS Control Regolatore ROS RPS Control
ROS Control RPS Control
122.5 [4.82]
370 [14.57]
122.5 [4.82]
370 [14.57]
299.7 [11.8]
299.7 [11.8]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O68 SH9V 165 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 1)
10 Control
133.2 [5.24]
133.2 [5.24]
213.8 [8.42]
213.8 [8.42]
103 [4.06]
137 [5.39]
51.5 [2.03] 137 [5.39]
240 [9.45]
Regolatore 2IN
2IE Control 2IN Control
2IN Control
187.6 [7.39]
187.6 [7.39]
133.2 [5.24]
133.2 [5.24]
213.8 [8.42]
213.8 [8.42]
X2 X2
103 [4.06]
74 [2.91] 74 [2.91] 51.5 [2.03]
X2: Piloting port - 7/16”-20 UNF-2B X2: Piloting port - 7/16”-20 UNF-2B
Regolatore REN
Regolatore REE REN Control
REE Control REE Control REN Control
192.1 [7.56]
192.1 [7.56]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 165 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 1) O69
10 Control
Regolatore RIN
Regolatore RIE RIN Control
RIE Control
RIE Control RIN Control
143.7 [5.66]
143.7 [5.66]
130.9 [5.15]
192.1 [7.56]
130.9 [5.15]
192.1 [7.56]
X2: Piloting port - 7/16”-20 UNF-2B X2: Piloting port - 7/16”-20 UNF-2B
206.2 [8.12]
111.4 [4.39]
130.9 [5.15]
192.1 [7.56]
111.4 [4.39]
192.1 [7.56]
X2: Piloting port - 7/16”-20 UNF X3: Double step piloting port - 7/16”-20 UNF
X3: Double step piloting port - 7/16”-20 UNF
DC5A1G1_0000000 - 01/22
SH9V-M/01
O70 SH9V 165 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 2)
10 Control
Regolatore 2EN
RPE Control 2EN Control 2EN Control
Regolatore RPE
RPE Control
Control starting
pressure adjustment
344.3 [13.55] 137 [5.39] 51.5 [2.03] 360.7 [14.2]
140 [5.51]
192.1 [7.56]
133.2 [5.24]
213.8 [8.42]
Regolatore REN
Regolatore 2IN
REN Control
2IN Control
2IN Control REN Control
119.2 [4.69]
102.6 [4.04]
192.1 [7.56]
300.5 [11.83]
66 [2.6] 45 [1.77]
133.2 [5.24]
225.2 [8.87]
230.6 [9.08]
230.1 [9.06]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 165 - Controls dimensions for mounting flange SAE-D 4 bolts (08) (Displ. setting 2) O71
10 Control
Regolatore ROI Regolatore RPI
ROI Control RPI Control
ROI Control RPI Control
133.2 [5.24]
133.2 [5.24]
230.1 [9.06]
225.2 [8.87]
225.2 [8.87]
230.1 [9.06]
X2: Piloting port - 7/16”-20 UNF-2B X2: Piloting port - 7/16”-20 UNF-2B
119.2 [4.69]
119.2 [4.69]
300.5 [11.83]
300.5 [11.83]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O72 SH9V 215 - Motor dimensions
158.2 [6.229]
31.8 [2.52]
113.1 [4.455]
120 [4.724]
105 [4.134]
Ø200 [7.874]
236 [9.291]
A
66.7[2.626]
14°
.626]
40.5 [1.595]
66.7 [2
217.7 [8.571]
31.8
S2 [1.25
115 [4.528]
32 [1.26] 2]
99 [3.898]
45° °
Max Stroke Adjustment 45
164 [6.457]
243 [9.567]
391.1 [15.399]
345.6 [13.607] Min. Stroke adjuster
304.5 [11.989] °
45 45°
75 [2.953] 199 [7.835]
27 [1.068] S1 Y1
C
Ø317.5 [12.5]
158.2 [6.229]
115 [4.5258] 133 [5.236]
31.8 [1.252]
Ø165.1 [6.5]
262 [10.315]
A B
.626]
66.7 [2
217.7 [8.571]
66.7 [2.626]
31.8
12.7 [0.5] [1.25
2]
Ø2
32 [1.26]
0.6
131 [5.157] S2
[0.
81
262 [10.315]
1]
164 [6.457]
243 [9.567] Max Stroke adjuster
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 215 - Shafts dimensions O73
Splined Splined
SAR shaft S19 shaft
S19
R SCANALATO/SPLINED
0x2x30x24 DIN 5480 Spline W50x2x30x24 - DIN 5480 15T 8/16 DPD 15T 8/16 DP
47.62 [1.87]
ø48 [1.89]
M16
M16
36 [1.42]
36 [1.42]
45 [1.77] 45 [1.77]
56 [2.20] 75 [2.95]
84.5 [3.33] 12.7 [0.50]
95 [3.74]
Splined
S19 shaft
ANALATO/SPLINED
8/16 DPD 15T 8/16 DP
47.62 [1.87]
M16
36 [1.42]
45 [1.77]
75 [2.95]
12.7 [0.50]
DC5A1G1_0000000 - 01/22
SH9V-M/01
O74 SH9V 215 - Controls dimensions for mounting flange ISO 4 bolts (OG) (Displ. setting 1)
10 Control
441.8 [17.39]
441.3 [17.38]
F1
381.7 [15.03] F1
359 [14.13]
375.9 [14.80]
F1 F1
381.7 [15.03] 359 [14.13]
F1
F1 359.1 [14.14]
381.7 [15.03]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 215 - Controls dimensions for mounting flange ISO 4 bolts (OG) (Displ. setting 1) O75
10 Control
89.5 3.52
89.5 3.52
42.5 1.67
Y1
Piloting port - 7/16"-20 UNF Control starting 42.5 1.67 X2
Pressure adjustment Y1
375.9 [14.80]
375.7 [14.79]
F1
F1 359 [14.13]
381.5 [15.02]
89.5 3.52
441.3 [17.38]
375.7 [14.79]
381.7 [15.03] F1
F1
Control starting 381.7 [15.03]
X2: Piloting port - 7/16"-20 UNF
X3: Double step Piloting port - 7/16"-20 UNF Pressure adjustment
DC5A1G1_0000000 - 01/22
SH9V-M/01
O76 SH9V 215 - Controls dimensions for mounting flange ISO 4 bolts (OG) (Displ. setting 2)
10 Control
F1 Y1
441.8 [17.39]
382.6 [15.06]
Y1
349.9 [13.78] F1
Control starting 89.5 [3.52] 42.5 [1.67]
Pressure adjustment 359 [14.13]
454.8 [17.91]
375.9 [14.80]
Y1
F1
Piloting port - 7/16"-20 UNF 359 [14.13]
349.9 [13.78] 89.5 [3.52] 42.5 [1.67]
Y1
F1
Piloting port - 7/16"-20 UNF 359 [14.13] 349.9 [13.78] 89.5 [3.52] 42.5 [1.67]
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 215 - Controls dimensions for mounting flange ISO 4 bolts (OG) (Displ. setting 2) O77
10 Control
F1 F1
383.1 [15.08]
383.1 [15.08]
Y Y1 X2 Y1
X2
Piloting port - 7/16"-20 UNF 349.9 [13.78] 89.5 [3.52] 42.5 [1.67] Piloting port - 7/16"-20 UNF 349.9 [13.78] 89.5 [3.52] 42.5 [1.67]
F1 F1
454.8 [17.91]
454.8 [17.91]
Y1 Y1
DC5A1G1_0000000 - 01/22
SH9V-M/01
O78 SH9V 215 - Controls dimensions for mounting flange SAE-E 4 bolts (10) (Displ. setting 1)
10 Control
441.8 [17.39]
441.3 [17.38]
F1 F1
391 [15.39]
413.7 [16.29]
89.5 [3.52]
89.5 3.52
Control starting 42.5 [1.67] 42.5 1.67
X2 Pressure adjustment Y1
X2
Y1
375.7 14.79
375.9 14.80
F1 F1
Piloting port - 7/16"-20 UNF 413.7 16.29 391.1 15.40
Piloting port - 7/16"-20 UNF
42.5 1.67
42.5 1.67
Control starting Y1
Pressure adjustment Y1
441.8 17.39
17.38
441.3
391.1 15.40 F1
F1
413.7 16.29
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 215 - Controls dimensions for mounting flange SAE-E 4 bolts (10) (Displ. setting 1) O79
10 Control
89.5 3.52
89.5 3.52
Y1 42.5 1.67
Control starting 42.5 1.67
X2 Pressure adjustment X2
Y1
375.9 14.80
375.7 14.79
441.3 [17.38]
375.7 [14.79]
410 [16.14] F1
F1
413.7 [16.29]
X2: Piloting port - 7/16"-20 UNF
X3: Double step Piloting port - 7/16"-20 UNF Double step Piloting port - 7/16"-20 UNF
DC5A1G1_0000000 - 01/22
SH9V-M/01
O80 SH9V 215 - Controls dimensions for mounting flange SAE-E 4 bolts (10) (Displ. setting 2)
10 Control
F1 F1
382.6 [15.06]
454.8 [17.91]
Y1
Y1
F1
F1
383.1 [15.08]
454.8 [17.91]
X2 Y1
Y1
383.1 [15.08]
Y1
391.1 [15.40] F1
381.9 [15.04] 89.5 [3.52] 42.5 [1.67]
Piloting port - 7/16”-20 UNF
DC5A1G1_0000000 - 01/22
SH9V-M/01
SH9V 215 - Controls dimensions for mounting flange SAE-E 4 bolts (10) (Displ. setting 2) O81
10 Control
F1 F1
383.1 [15.08]
383.1 [15.08]
Y1 X2 Y1
X2
F1
F1
454.8 [17.91]
Y1 454.8 [17.91]
Y1
DC5A1G1_0000000 - 01/22
SH9V-M/01
O82 Flushing valve
For closed circuit operation, the motors can be equipped with built in flushing valve.
B X2
B Y1
Vgmin
A Vgmax
A S2
S1
B X2
B Y1
Vgmin
A Vgmax
A S1 S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
Flushing valve O83
B S1
Y1
Vgmin
Vgmax
A S2
DC5A1G1_0000000 - 01/22
SH9V-M/01
O84 Tachometer
TS - TW - TZ
B TS TZ-TW
A
phonic wheel assembles on rotating group
without sensor.
Size
SH9V061 ME SH9V085 ME SH9V115 ME SH9V165 ME SH9V215 ME SH9V061 SE SH9V085 SE SH9V115 SE SH9V165 SE SH9V215 SE
A mm 64 [2.52] 79.9 [3.14] 88.9 [3.49] 96.9 [3.81] 101.9 [4.01] 88 [3.46] 79.9 [3.14] 88.9 [3.49] 96.9 [3.81] 101.9 [4.01]
B mm 75.5 [2.97] 76.5 [3.01] 86.5 [3.40] 92.5 [3.64] 105 [4.13] 75.5 [2.97] 100.5 [3.95] 120.5 [4.74] 124.5 [4.90] 105 [4.13]
TW TZ
2-Channel differential-hall effect operating principle (1 square 2-Channel differential-hall effect operating principle Sensor
wave -1 digital for direction of rotation) Output signal PNP with dual-channel output (90°)
Power supply 4.5-16 VDC Power supply 8-32 VDC
Frequency 0 - 20.000 Hz Frequency 0-20.000 Hz
Operating temperature -40°C - +110°C Operating temperature -40°C +125°C
Degree of protection IP67
Sensor connector Deutsch DT04-4P
Electromagnetic compatibility according to EN 60947-5-2
Resistence to schock and vibration in accordance with IEC
68-2-17 IEC 68-2-6
Size
DC5A1G1_0000000 - 01/22
SH9V-M/01
DC5A1G1_0000000 - 01/22
DC5A1G1_0000000 - 01/22
MAV4211SH - Electronic control card P1
Index
DC5A1G1_0000000 - 01/22
MAV4211SH/01
P2 General information - Features
The MAV4211SH controller unit is used for the control of variable displacement pumps and motors and additional switching functions.
The proportional solenoid outputs are pulse -width-modulated (PWM) and optimally adapted for electric proportional control of Dana
products. The switched outputs are designed for the direct switching of relays, lamps and switching solenoids. The MAV4211SH
unit can managed up to 2 analog input signal and 4 PWM current output. Connecting the card properly, can be used in at least 5
different applications.
The RS232 serial interface and BPE software tool enables the connection of PC for service functions, such as diagnostics, parameter
setting or display of process variables. The software is free downloadable from internet site:
http://www.bpe-electronics.it/upload/bpeterminal.zip
Main features:
- CE requirements: European norms: EN61000-ElectroMagnetic Compatibility (EMC) - industrial environment.
Additional features:
- Aerial platforms
- Mobile cranes
- Agricultural machines
- Handling machines
DC5A1G1_0000000 - 01/22
MAV4211SH/01
Technical data P3
Interfaces RS232
MAV - Enable 1
Forward / Reverse 2
DC5A1G1_0000000 - 01/22
MAV4211SH/01
P4 Ordering code
DC5A1G1_0000000 - 01/22
MAV4211SH/01
Contacts description P5
SICMA 2
8 1
pin 8 7 6 5 4 3 2 1
A On/off output Brake 1 Input EMDV Return PWM 1 A and B PWM out A2 Input Fw / Rw Pos (+) Supply
pin 8 7 6 5 4 3 2 1
B PWM out B1 Return PWM A3 Return PWM A2 input enable Analog input CH1 Analog input CH3 PWM out A3
pin 8 7 6 5 4 3 2 1
C PWM out A2 5V joystick supply PWM out A1 On/off output Brake 2 Analog input Analog input Input Fw/Rw Neg (-) Supply
CH2 CH4
Note:
The negative (0V) of joysticks supply or pedal has to be connected to the negative of battery.
AMP
2
1
GND RX TX
DC5A1G1_0000000 - 01/22
MAV4211SH/01
P6 Dimensions
49.7 [1.96]
3 [0.12]
29 [1.14]
132 [5.20]
118 [4.645]
83 [3.27]
Ø5
[0.
2]
41.5 [1.634]
LAYOUT
Mating Connector
LED
DC5A1G1_0000000 - 01/22
MAV4211SH/01
Working modes P7
MODES 1
Control of one circuit closed pump
Travel pedal
Forward, reverse
switches
Engine
MODES 2
Control of two independent closed circuit pumps.
Engine
DC5A1G1_0000000 - 01/22
MAV4211SH/01
P8 Working modes
MODES 3
Control of two closed circuit pumps in tandem configuration.
Travel pedal
Forward, reverse
switches
Engine
MODES 4
Control of two independent (motors) or open circuit pumps.
Engine
DC5A1G1_0000000 - 01/22
MAV4211SH/01
Working modes P9
MODES 5
Control of one circuit closed circuit pump and one or two variable displacement motors.
Travel pedal
Forward, reverse
switches
Engine
DC5A1G1_0000000 - 01/22
MAV4211SH/01
DC5A1G1_0000000 - 01/22
Valves Q1
Index
DC5A1G1_0000000 - 01/22
VALVES/01
Q2 General information - Features
Pb Pa
VSC
VSC20L
H1CR
Overcentre valves
C1 C2
VCD/M
SH11C SH11CR
VCD/1
VCD/2
V1 C3 V2
Anti-shock valves
H2V
M
VSD 120
P T
Check valves
M
SH7V SH7VR VU165
P T
Overcentre valves
C1 C2 VCR1 D/AF
VCR2 D/AF
VCR3
V1 C3 V2
VCR4
H1V
Sequence valves
Pe
T VSI
Pm
DC5A1G1_0000000 - 01/22
VALVES/01
Technical data VSC Q3
The VSC flushing valve allows an oil cooling action, which is recommended when operating at high speed and power.
The unit is made by a three positions - three way spool valve that allows a small oil flow from the low pressure line of the circuit into
the motor casing without external piping (only H2V 226 still need an external line), then into the tank. For a correct operation
it is necessary to connect the drain port of the motor with the tank.
6.5 [0.255]
9 [0.354]
60 [2.36]
16 [0.63]
30 [1.18]
20 [0.79]
Pb Pa
Pb
65 [2.56]
36 [1.42]
Pa
M6
80 [3.15]
DC5A1G1_0000000 - 01/22
VALVES/01
Q4 Flushing valves dimensions VSC20L
V1 V2
41 [1.61]
T
T
10 [0.393]
90 [3.54]
V1 V2
1/2 G (BSPP)
1” G (BSPP)
Ø8
74 [2.91]
24 [0.94]
.5 60 [2.36] 65 [2.56]
[0.
33 V1 T V2
4]
VSC20L - Flushing valves with flow ˜ 20 l/min [5.28 U.S. gpm] at 21 bar [304 psi] - (in line version).
DC5A1G1_0000000 - 01/22
VALVES/01
Motors predisposition VSC Q5
To mount the flushing valve on H1C-H1CR motors with LM2 ports cover, it is necessary to provide the covers below indicated:
To mount the flushing valve on H1C-H1CR motors with VM2 ports cover, it is necessary to provide the covers below indicated:
L2 H2V motors
To mount the flushing valve on H2V motors with L2 ports cover, it is necessary to provide the covers below indicated:
(*) An external line for the flushing valve output flow is required
- not provided
DC5A1G1_0000000 - 01/22
VALVES/01
Q6 Motors predisposition VSC
SH11C-SH11CR / LM2
To mount the flushing valve on SH11C-SH11CR motors with LM2 ports cover, it is necessary to provide the covers below
indicated:
31760800000 Port cover LM2 VSC SH11C 20/28/32 ISO (ME) SH11C/SH11CR 020/030 ME
1
31760950000 Port cover LM2 VSC SH11C 20/28/32 SAE (SE) SH11C/SH11CR 020/030 SE
31754750000 Port cover LM2 ISO (ME) for flushing valve SH11C/SH11CR 055/063 ME
2
31756900000 Port cover LM2 SAE (SE) for flushing valve SH11C/SH11CR 055/063 SE
31755400000 Port cover LM2 ISO (ME) for flushing valve SH11C/SH11CR 075/090 ME
3
31729150000 Port cover LM2 SAE (SE) for flushing valve SH11C/SH11CR 075/090 SE
31756500000 Port cover LM2 ISO (ME) for flushing valve SH11C/SH11CR 108/125 ME
4
31759700000 Port cover LM2 SAE (SE) for flushing valve SH11C/SH11CR 108/125 SE
31757700000 Port cover LM2 ISO (ME) for flushing valve SH11C/SH11CR 160/180 ME
5
31703900000 Port cover LM2 SAE (SE) for flushing valve SH11C/SH11CR 160/180 SE
SH11C-SH11CR / VM2
To mount the flushing valve on SH11C-SH11CR motors with VM2 ports cover, it is necessary to provide the covers below
indicated:
1 31761100000 Port cover VM2 VSC SH11C 20/28/32 SAE (SE) SH11C/SH11CR 020/030 ME/SE
2 31757150000 Port cover VM2 SAE for flushing valve SH11C/SH11CR 055/063 ME/SE
3 31729250000 Port cover VM2 SAE for flushing valve SH11C/SH11CR 075/090 ME/SE
4 31759950000 Port cover VM2 SAE for flushing valve SH11C/SH11CR 108/125 ME/SE
5 31706300000 Port cover VM2 SAE for flushing valve SH11C/SH11CR 160/180 ME/SE
DC5A1G1_0000000 - 01/22
VALVES/01
Pilot assisted overcentre valves for motors VCD Q7
The pilot assisted overcentre valves prevent the motor from “running ahead” pulled by a driving load and allow cavitation
free operation. The relief section limits the pressure shocks. These valves incorporate also a shuttle valve to release the fail
safe brake. These valves are supplied flangeable on H1C-SH11C-SH11CR/LM2, H1C-H1CR-SH11C-SH11CR/VM2, or H2V/
L2 ports covers.
The setting pressure value must be approx. 1.3 times the load induced pressure.To allow the descent of the load, a minimum pilot
pressure must be supplied to the control valve. This is usually determined with the following formula:
PS - PL
PP =
R+1
where:
PP = pilot pressure
PS = pressure setting of relief valve section
PL = load induced pressure
R = piloting ratio
G 1/4”
C1 C2
C D E F
C3
N
V1
V2
O
C2 C1
V1 C3 V2
M M
30 ÷ 350 350
SPA00000368* 6.2:1 Aluminium
[435 ÷5075] [92.4]
G
30 ÷ 350 350
L
30 ÷ 350 350
SPA00000370* 6.2:1 Aluminium
[435 ÷5075] [92.4]
I J I H 140 ÷ 350 300
SPA00000756 4:1 Steel
[2030 ÷5075] [79.2]
DC5A1G1_0000000 - 01/22
VALVES/01
Q8 Pilot assisted overcentre valves for motors VCD
VCD/1
U1
10 [0.393] 140 [5.51] 10 [0.393] 10 [0.393] 140 [5.51] 10 [0.393]
35 [1.377] A
50 [1.968]
F
65 [2.559]
Pp
100 [3.93]
110 [4.33]
U1
68.6 [2.70]
Pp U1
68 [2.70]
Pp
50 [1.968]
B
50 [1.968]
65 [2.559]
65 [2.559]
35 [1.37]
21 [0.826] D1 21 [0.826]
10 [0.393]
10 [0.393]
M10 D1 F
43 [1.692] 82 [3.228] 35 [1.377]
29 [1.14]
29 [1.14]
43 [1.69] 82 [3.22]
220 [8.66]
2.05 [0.080]
83 [3.26] 77 [3.03] 60 [2.36] Valve Piloting Setting MAX flow Material
Ø14 [0.551]
Pp U1 28 [1.10] Ø19 [0.748] ratio range rate
D1
70 [2.75]
bar l/min
41 [1.61]
F Pp [psi] [U.S.gpm]
E
7 [0.275]
Ø4 [0.157] U1 ØC
0 ÷ 350 180
2.05 [0.080]
1.25 [0.049]
0 ÷ 350 180
SPA00000366 2.9:1 Steel
[0 ÷ 5075] [47.5]
0 ÷ 350 180
SPA00000367 2.9:1 Steel
Valve is supplied with screws and O-rings [0 ÷ 5075] [47.5]
VCD/2
n. 4 holes ØF1 ØF C2
P P
S2
S3
P C3
S1
C3 C3
0-Ring C2 L6
V2 V2
29 [1.14] L 59 [2.34]
L1 L2
P C3 V2
Valve Piloting Setting MAX MAX flow Material
ratio range pressure rate
(*) The mounting on SH7VR, needs an additiona flange. For more information please contact Dana Brevini.
DC5A1G1_0000000 - 01/22
VALVES/01
Internal piloting sequence valve VSI Q9
The internal piloting sequence valve is meant to add a constant pressure control on the pumps standard controls with displace-
ment setting 1 (Vg max → Vg min).
VSI x CR
The valve VSI x CR (code 65002210000) is used only for CR controls.
17 [0.67]
Pe
153.8 [6.06]
30 [1.18]
Pe T
120 [4.72]
100 [3.94]
80 [3.15]
T
75 [2.95]
Pm Pm
VSI 2
The valve VSI 2 (code 65009020000) is used only as a spare part for valves (code 44081520000) used on the old PCR and
+PC controls.
For more informations, see the Service Bulletin 03-0094-A01.
Pe
153.8 [6.06]
100 [3.94]
Pe T
80 [3.15]
120 [4.72]
T
91.5 [3.60]
Pm
Pm
30 [1.18]
DC5A1G1_0000000 - 01/22
VALVES/01
Q10 Motion control valve VCR
304 [11.96]
210 [8.26]
26 [1.02] 26 [1.02]
69.4 [2.73]
C1 C2
V1 C3 V2
A
24 [0.94]
n. 2 0-ring
1/4” GAS
V1 C3 V2
C3
25 [0.98]
V1 V2
C
D
26 [1.024] 26 [1.024]
20 [0.79]
V2 V1 C1 C2
C3
V
C2 C1
S S CH.17
CH.32
C3
V2 V1
Q
R
V1 C3 V2
T U T
DC5A1G1_0000000 - 01/22
VALVES/01
Motion control valve VCR Q11
C1 C2
M1 M2
1 2
DR
L
N
DR DR
25 [0.98]
BR
D
3
H BR BR
B C 0-Ring
I S V1 V2
4.5 [0.177] A
F
E
B C
G
p p
psi bar psi
psi bar
bar
psi bar
540 36 540 36
480 480
420 30 420 30
Pressure
V2-C2
Pressure
360 24 360 24
300 C2-V2 300
18 18
240 240
180 12 180 12
V2-C2 C2-V2
120 120
6 6
60 60
0 0 0
0 30 60 90 120 150
l/min 0 60 120 180 240 300 l/min
q q
0 3 6 9 12 15 18 21 24 27 30 33 36 39 U.S. gpm 0 6 12 18 24 30 36 42 48 54 60 66 72 78
U.S. gpm
Flow Flow
DC5A1G1_0000000 - 01/22
VALVES/01
Q12 Motion control valve VCR
73.5 [2.89]
15 [0.59]
C1 C2
M1 M2
1 2
DR
109 [4.29]
41 [1.61] BR
M1 M2
DR DR
C1 C2 41 [1.61] 3
0-Ring 2-221 14.5 [0.57] 110 [4.33]
48 [1.89] 99 [3.90]
BR BR
V1 V2 V1 V2
31.75 [1.25]
110 [4.33]
84 [3.31]
4.5 [0.177]
66.68 [2.625]
48 [1.89] 99 [3.90]
p
psi
psi bar
bar
540 36
480
420 30
V2-C2
360
Pressure
24
300
18
240
C2-V2
180 12
120
6
60
0 0
0 64 128 192 256 320 l/min
q
0 6 12 18 24 30 36 42 48 54 60 66 72 78 84 U.S. gpm
Flow
DC5A1G1_0000000 - 01/22
VALVES/01
Motion control valve VCR Q13
N C1 C2
L L L
1 2
M1 M2
P
O
V2 V2
Dr
3
I
I
H
M
M
M2 M1
C3
B
I
V1 V2
E
C G G N
0-Ring
F
A 60 [2.36]
C3 Dr
75 [2.95]
64 [2.52]
Valve Piloting MAX Nominal MAX flow Standard Standard Setting Pressure Material
ratio pressure flow rate setting flow rate range increase
SH7V mm mm mm mm mm mm mm mm mm mm mm mm mm mm
SH7VR [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]
FM
60 12.25 12 19 41 180 49 155 57.15 27.76 107 35 20
SPA00000818 075/108 [2.36] [0.48] [0.47] [0.75] [1.614] [7.08] [193] [6.10] [2.25] [1.093] [4.212] [1.378]
M12
[0.78]
70 14.5 14 22 44 200 54 160 66.68 31.75 112 36 22
SPA00000819 160 [2.75] [0.57] [0.55] [0.86] [1.732] [7.87] [2.12] [6.30] [2.625] [1.25] [4.409] [1.417]
M14
[0.86]
DC5A1G1_0000000 - 01/22
VALVES/01
Q14 Check valve and Anti-Shock valve
The valve is used in unidirectional applications when the motor is subject to high inertial loads, avoiding cavitation during
the motor decelerations.
To mount the check valve on H1C-SH11C motors with LM2 ports cover, it is necessary a dedicated cover.
O-Ring 5-256
38 [1.50]
45 [1.77]
Ø12 [0.472]
M
120 [4.72] P
P T
64 [2.52]
50 [1.97]
O-Ring 123
Ø12 [0.472]
Ø11 [0.433]
Ø6.5 [0.255]
T Valve MAX MAX
7 [0.275] 36 [1.42] 7 [0.275] pressure flow
18 [0.71]
25 [0.98]
9 [0.354]
These valves have the purpose to protect the motor from pressure spikes. The response time is very short, being
this valves directly operated. When the pressure in the system exceeds the setting of the valve, the spool opens and
discharges an amount of flow to the low pressure side.
To mount the anti-shock valve on H1C226 motors with LM2 ports cover, it is necessary a dedicated cover.
CH. 30
O-Ring 123
36 [1.42]
43 [1.69]
185.7 [7.31]
Ø12.5 [0.49]
P T
77 [3.03]
117 [4.61]
G 1/4” BSP
50 [1.97]
O-Ring 123
64 [2.5]
n.4 M6x50
40 [1.57]
Ø12.5 [0.49]
Ø6.5 [0.3]
Ø11 [0.43]
Valve MAX
24 [0.94]
17 [0.67]
DC5A1G1_0000000 - 01/22
VALVES/01
DC5A1G1_0000000 - 01/22
Technologies
Customized to
Every Part
of the Globe
With a presence in 33 countries,
Dana Incorporated boasts more than
150 engineering, manufacturing,
and distribution facilities. Our worldwide
network of local service centers provides
assurance that each customer will benefit
from the local proximity and responsiveness.
About Dana Incorporated About Dana Off-Highway Drive and Motion Technologies
Dana is an integral partner for virtually Dana delivers fully optimized Spicer® drivetrain and Brevini® motion systems to customers
every major vehicle and engine in construction, agriculture, material-handling, mining, and industrial markets.
manufacturer worldwide. We are a leading We bring our global expertise to the local level with technologies customized to individual
supplier of drivetrain, sealing, and thermal requirements through a network of strategically located technology centers, manufacturing
technologies to the global automotive, locations, and distribution facilities.
commercial-vehicle, and off-highway
markets. Founded in 1904, we employ
thousands of people across six continents.
Dana-Industrial.com
Application Policy
Capacity ratings, features, and specifications vary depending
upon the model and type of service. Application approvals
must be obtained from Dana; contact your representative for
application approval. We reserve the right to change or modify
our product specifications, configurations, or dimensions at
any time without notice.