You are on page 1of 7

\ D’Info NO.

CS 20-05 27 November 2020


No. CS 20-01

FEATURES OF WIFI CONTROL

CONVENIENCE
• In-home & Out-of-home operation allow
user to stay in control of their unit
anywhere and anytime.
• Weekly scheduling allow user to pre-set
multiple units at different location
effortlessly just from a device.

PEACE OF MIND
• Remote monitoring for you to monitor
your unit operation in real time.
• Error code message shows the error occurs
to your unit.

COMFORT
• Various operation modes to suit every
user’s need.
• Advance control for better cooling comfort.

SMART ENERGY
• Energy usage monitoring to keep track of
your energy usage for more optimization
cooling comfort.
• Historical data analysis to compare with
previous energy usage data.
\ D’Info NO. CS 20-05 27 November 2020
No. CS 20-01

R32 SINGLE SPLIT INVERTER


WALL MOUNTED
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
1.0 FTKF25AV1M RKF25AV1M 9,000 (3400 - 9000) / X X
1.5 FTKF35AV1M RKF35AV1M 12,300 (4,100-13,000) / X X
2.0 FTKF50AV1M RKF50AV1M 18,000 (5,200-18,500) / X X
2.5 FTKF71AV1M RKF71AV1M 24,000 (6,600-24,500) / X X

CEILING CASSETTE
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
2.0 FCF50CVM RZF50CVM 17,100 (10,900-19,100) X / /
2.5 FCF60CVM RZF60CVM 20,500 (10,900-20,500) X / /
3.0 FCF71CVM RZF71CVM 24,200 (10,900-27,300) X / /
4.0 FCF100CVM RZF100CVM 34,100 (17,100-38,200) X / /
5.0 FCF125CVM RZF125CVM 42,700 (19,500-47,800) X / /
5.5 FCF140CVM RZF140CVM 47,800 (21,200-52,900) X / /

CEILING DUCTED
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
2.0 FBA50BVMA RZF50CVM 17,100 (10,900-19,100) X / /
2.5 FBA60BVMA RZF60CVM 20,500 (10,900-20,500) X / /
3.0 FBA71BVMA RZF71CVM 24,200 (10,900-27,300) X / /
4.0 FBA100BVMA RZF100CVM 34,100 (17,100-38,200) X / /
5.0 FBA125BVMA RZF125CVM 42,700 (19,500-47,800) X / /
5.5 FBA140BVMA RZF140CVM 47,800 (21,200-52,900) X / /

CEILING EXPOSED
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
2.0 FHA50BVMA RZF50CVM 17,100 (10,900-19,100) X / /
2.5 FHA60BVMA RZF60CVM 20,500 (10,900-20,500) X / /
3.0 FHA71BVMA RZF71CVM 24,200 (10,900-27,300) X / /
4.0 FHA100BVMA RZF100CVM 34,100 (17,100-38,200) X / /
5.0 FHA125BVMA RZF125CVM 42,700 (19,500-47,800) X / /
5.5 FHA140BVMA RZF140CVM 47,800 (21,200-52,900) X / /
/ - Available
X - Not Available
\ D’Info NO. CS 20-05 27 November 2020
No. CS 20-01

R32 SINGLE SPLIT NON INVERTER


WALL MOUNTED
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
1.0 FTV28PV1L RV28FV1P 9,500 / X /
1.5 FTV35PV1L RV35FV1P 12,000 / X /
2.0 FTV50PV1L RV50CV1P 18,000 / X /
2.5 FTV60PV1L RV60CV1P 22,000 / X /
3.0 FTV85PSV1L RC85AV1P 30,000 / X /

CEILING CASSETTE
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
1.0 FFC25AV1MF RC25A 9,500 / X X
1.5 FFC35AV1MF RC35A 12,500 / X X
2.0 FCC50AV1M RC50AV1M 18,500 / X /
2.5 FCC60AV1M RC60AV1M 24,000 / X /
3.0 FCC85AV1M RC85AV1M 30,000 / X /
3.5 FCC100AV1M RC100AV1M 36,000 / X /
4.0 FCC125AV1M RC125AY1M 42,000 / X /
5.0 FCC140AV1M RC140AY1M 48,000 / X /

CEILING DUCTED
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
2.0 FDMC50AV1M RC50AV1M 18,500 X X /
2.5 FDMC60AV1M RC60AV1M 23,500 X X /
3.0 FDMC85AV1M RC85AV1M 30,000 X X /
3.5 FDMC100AV1M RC100AV1M 36,000 X X /
4.0 FDMC125AV1M RC125AY1M 42,000 X X /
5.0 FDMC140AV1M RC140AY1M 48,000 X X /
6.0 FDMC160AV1M RC160AY1M 55,000 X X /

CEILING EXPOSED
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
2.0 FHC50AV1M RC50AV1M 18,500 X / /
2.5 FHC60AV1M RC60AV1M 23,500 X / /
3.0 FHC85AV1M RC85AV1M 29,500 X / /
3.5 FHC100AV1M RC100AV1M 36,000 X / /
4.0 FHC125AV1M RC125AY1M 42,000 X / /
5.0 FHC140AV1M RC140AY1M 46,000 X / /
6.0 FHC160AV1M RC160AY1M 55,000 X / /
/ - Available
X - Not Available
\ D’Info NO. CS 20-05 27 November 2020
No. CS 20-01

R410A SINGLE SPLIT INVERTER


CEILING CASSETTE
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
1.0 FFR10CV1 RR10DV1 9,500 (3,650-12,000) X / /
1.5 FFR15CV1 RR15DV1 12,500 (4,800-14,000) X / /
2.0 FCQ50KAVEA RZR50MVM 17,100 (7,900-19,100) X / /
2.5 FCQ60KAVEA RZR60MVM 20,500 (8,900-21,500) X / /
3.0 FCQ71KAVEA RZR71MVM 24,200 (10,900-27,300) X / /
4.0 FCQ100KAVEA RZR100MVM 34,100 (17,100-38,200) X / /
5.0 FCQ125KAVEA RZR125MVM 42,700 (19,500-47,800) X / /
5.5 FCQ140KAVEA RZR140MVM 47,800 (21,200-52,600) X / /

CEILING DUCTED
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
1.0 FDMR10CV1M RR10DV1 9,200 (4,100-10,500) X / /
1.5 FDMR15CV1M RR15DV1 12,500 (4,600-14,000) X / /
2.0 FBQ50EVE RZR50MVM 17,100 (7,900-19,100) X / /
2.5 FBQ60EVE RZR60MVM 20,500 (8,900-21,500) X / /
3.0 FBQ71EVE RZR71MVM 24,200 (10,900-27,300) X / /
4.0 FBQ100EVE RZR100MVM 34,100 (17,100-38,200) X / /
5.0 FBQ125EVE RZR125MVM 42,700 (19,500-47,800) X / /
5.5 FBQ140EVE RZR140MVM 47,800 (21,200-52,600) X / /

CEILING EXPOSED
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
1.5 FLR15EV1 RR15DV1 12,500 (5,400-14,000) X / /
2.0 FHQ50DAVMA RZR50MVM 17,100 (7,900-19,100) X / /
2.5 FHQ60DAVMA RZR60MVM 20,500 (8,900-21,500) X / /
3.0 FHQ71DAVMA RZR71MVM 24,200 (10,900-27,300) X / /
4.0 FHQ100DAVMA RZR100MVM 34,100 (17,100-38,200) X / /
5.0 FHQ125DAVMA RZR125MVM 42,700 (19,500-47,800) X / /
5.5 FHQ140DAVMA RZR140MVM 47,800 (21,200-52,600) X / /
/ - Available
X - Not Available
\ D’Info NO. CS 20-05 27 November 2020
No. CS 20-01

R410A SINGLE SPLIT NON INVERTER


CEILING CASSETTE
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
1.0 FFN10CV1 RN10FV1 9,500 X / /
1.5 FFN15CV1 RN15FV1 12,500 X / /
2.0 FCN20FV1 RN20CV1 18,500 X / /
2.5 FCN25FV1 RN25CV1 23,000 X / /
2.8 FCN30FV1 RN28CV1 28,000 X / /
3.0 FCN30FV1 RN30CV1 30,000 X / /
3.5 FCN35FV1 RN35DV1 36,000 X / /
4.0 FCN40FV1 RN40DY1 42,000 X / /
5.0 FCN50FV1 RN50DY1 46,000 X / /

CEILING DUCTED
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
1.0 FDBN10CV1 RN10FV1 9,000 X X /
1.5 FDBN15CV1 RN15FV1 12,000 X X /
2.0 FDBN20CV1 RN20CV1 18,000 X X /
2.5 FDBN25CV1 RN25CV1 21,000 X X /
2.8 FDMN30CV1 RN28CV1 28,000 X X /
3.0 FDMN30CV1 RN30CV1 30,000 X X /
3.5 FDMN40CV1 RN35DV1 36,000 X X /
4.0 FDMN40CV1 RN40DY1 42,000 X X /
5.0 FDMN50CV1 RN50DY1 47,000 X X /
6.0 FDMN60CV1 RN61DY1 55,000 X X /

CEILING EXPOSED
COOLING CAPACITY. at 19°CWB BUILD-IN OPTIONAL WIRED – NO
HP FCU CU
(btu/hr) WIFI WIFI WIFI
1.5 FHN15CBV1 RN15FV1 12,500 X / /
2.0 FHN20CBV1 RN20CV1 18,000 X / /
2.5 FHN25CBV1 RN25CV1 21,000 X / /
2.8 FHN30CBV1 RN28CV1 27,000 X / /
3.0 FHN30CBV1 RN30CV1 29,000 X / /
3.5 FHN35CBV1 RN35DV1 35,000 X / /
4.0 FHN40CBV1 RN40DY1 41,000 X / /
5.0 FHN50CBV1 RN50DY1 44,500 X / /
6.0 FHN62CV1 RN61DY1 55,000 X / /
/ - Available
X - Not Available
\ D’Info NO. CS 20-05 27 November 2020
No. CS 20-01

OVERVIEW OF BUILD-IN WIFI

Indoor Unit

Log In Through Apps

Internet Router

OVERVIEW OF OPTIONAL WIFI

Wifi Accessory
Indoor Unit

Log In Through Apps


Internet Router
\ D’Info NO. CS 20-05 27 November 2020
No. CS 20-01

OVERVIEW OF VRV REMOTE CONTROL

Log in through Browser

You might also like