5.

0 FOUNDATIONS
GENERAL 5.01 FOUNDATIONS HAVE BEEN DESIGNED FOR THE FOLLOWING ALLOWABLE PRESSURES: 7.0 REINFORCEMENT
1.01 TECHNICAL SPECIFICATIONS OR SPECIFIC INSTRUCTIONS ON DRAWINGS 7.01 REINFORCEMENT SYMBOLS
TAKE PRECEDENCE OVER THESE NOTES. S DENOTES GRADE 250 S HOT ROLLED DEFORMED BARS TO AS
ELEMENT BEARING SHAFT ELEMENT SURFACE PRIME COAT SECOND COAT THIRD COAT
1.02 THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH AL 4671
PRESSURE (kPa) ADHESION (kPa) PREPARATION
ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS N DENOTES GRADE D500 N BARS TO AS 4671 GRADE N
AND WITH SUCH OTHER WRITTEN INSTRUCTIONS AS MAY BE ISSUED DURING THE WAFFLE SLAB,PAD & SL &RL DENOTES GRADE 250 HOT ROLLED PLANS BARS TO AS 4671 ABRASIVE BLAST 2 COATS R.O.Z.P
STRIP FOOTINGS 150 - ALL U.N.O REFER REFER
COURSE OF THE CONTRACT,ANY DISCREPANCY SHALL BE REFERRED TO THE SQUARE CLASS 2.5 (MIN.DRY FILM ARCHITECT ARCHITECT
ENGINEER BEFORE PROCEEDING WITH THE WORK.CONSTRUCTION FROM THESE PILES 300 25 RECTANGULAR MESH RESPECTIVELY THICKNESS TO 75
DRAWINGS AND THEIR ASSOCIATED CONSULTANCTS DRAWINGS IS NOT TO R DENOTES GRADE 250 HOT ROLLED PLAIN BARS TO AS 4671 ALL EXTERNAL MICRONS)
W DENOTES HARD-DRAWN PLAIN WIRE TO AS 4671 HOT DIP REFER REFER
COMMENCE UNTIL APPROVED BY THE LOCAL AUTHORITIES. STTELWORK -
ARCHITECT ARCHITECT
1.03 ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE 5.02 THE FOUNDATION MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER FOR THIS NUMBER OFDW BARS IN DENOTES COLD ROLLED RIBBED
BAR GRADE WIRE
AND TO AS 4671
TYPE (INCL.LINTELS)
GALVANISED
RELEVANT AND CURRENTSTANDARDS AUSTRALIA CODES AND WITH BY-LAWS & BEARING CAPACITY BEFORE PLACING ANY MEMBRANE,REINFORCEMENT OR CONCRETE,WHERE GROUP
ORDINACES OF THE RELEVANT BUILDING AUTHORITIES EXCEPT WHERE VARIEDNECESSARY,THE FOOTING DESIGN MAY BE ALTERED.
BY THE PROJECT SPECIFICATION. 5.03 SITE CLASSIFICATION IS ASSUMED CLASS "M" IN ACCORDANCE WITH AS2870,THIS IS TO BE
1.04 ALL DIMENSIONS SHOWN SHALL BE VERIFIED BY THE BUILDER ON CONFIRMED ON SITE ON SITE AFTER EXCAVATION HAS TAKEN PLACE. 17N20-250 9.12 THE BUILDER SHALL PROVIDE ALL CLEATS AND DRIL ALL HOLES
SITE.ENGINEER'S DRAWINGS SHALL NOT BE SCALED FOR DIMENSIONS 5.04 THE BUILDER SHALL BE RESPONSIBLE FOR MAINTAINING ANY EXCAVATIONS IN A STABLE CONDITION NECESSARY FOR FIXING STEEL TO STEEL AND TIMBER TO STEEL
1.05 DURING CONSTRUCTION THE STRUCTURE AND ANY ASSOCIATED WITHOUT ADVERSELY AFFECTING SURROUNDING PROPERTIES INCLUDING SERVICES,THIS INCLUDES NOMINAL BAR SIZE IN mm WHETHER OR NOT DETAILED IN THE DRAWINGS.
OBTAINING ALL NECESSARY APPROVALS FOR SHORING AND ANCHORING SYSTEMS. BAR SPACING IN mm 9.13 FREE ALL MEMBERS FROM TWISTS AND DISTORTIONS BEFORE AND
EXCAVATIONS SHALL BE MAINTAINED IN A STABLE CONDITION AND NO PART
SHALL BE OVERSTRESSED.TEMPORARY BRACING SHALL BE PROVIDED BY THE 5.05 FOOTING SHALL BE LOCATED CENTRALLY UNDER WALLS AND COLUMNS UNLESS NOTED AFTER WELDING.
BUILDER TO KEEP THE WORKS AND EXCAVATIONS STABLE AT ALL TIMES. OTHERWISE. THE FIGURES FOLLOWING THE FABRIC SYMBOL IS THE REFERENCE NUMBER FOR 9,14 ALL MEMBERS TO BE IN ONE LENGTH,UNLESS OTHERWISE
APPROVED.
1.06 UNLESS NOTED OTHERWISE,ALL DIMENSIONS ARE IN MILLIMETERS (mm) 5.06 FOOTING NEAR BOUNDARIES MUST NOT BE LOCATED HIGHER OR LOWER THAN FOOTNGS OF FABRIC TO AS 4671
AND ALL LEVELS ARE IN METERS (m) TO AUSTRALIAN HEIGHT DATUM (AHD). ADJACENT PROPERTIES UNLESS APPROVED. 7.02 ALL REINFORCEMENT SHALL FIRMLY SUPPORTED ON MILD STEEL PLASTIC TIPPED
1.07 ALL ABBREVIATIONS ARE IN ACCORDANCE WITH AS1100.ADDITIONAL 5.07 WHERE FOOTINGS ARE OVER-EXCAVATED,FILL OVER-EXCAVATED AREAS WITH BINDING CONCRETE CHAIRS OR CONCRETE CHAIRS AT NOT GREATER THAN 1 METER CENTRES BOTH
ABBRVIATIONS USED ARE AS FOLLOWS: GRADE SAME AS FOOTING TO A MINIMUM THICKNESS OF 50 mm. WAYS,BARS SHALL BE TIED AT ALTERNATE INTERSECTIONS.IN EXPOSURE CONSITIONS 10.0 STRUCTURAL TIMBER
NSOP NOT SHOWN ON PLAN 5.08 KEEP FOOTING CLEAN AND FREE OF LOOSE MATERIAL BEFORE INSPECTION,IMMEDIATELY PRIOR TO GREATHER THAN B1 ONLY PLASTIC CHAIRS. 10.01 ALL TIMBER DESIGN CONSTRUCTION AND MATERIAL TO BE AS
NSOE NOT SHOWN ON ELEVATION POURING OF CONCRETE,AND DURING POURING. 7.03 REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY AND NOT NECESSARILY IN 1720.1 AND AS 1720.2 U.N.O.
UNO UNLESS NOTED OTHERWISE 5.09 DO NOT EXCEED A RISE OF 1000 mm IN A RUN OF 3000 mm FOR THE LINE UNTIL OF SLOPE BETWEEN TRUE PROJECTION. 10.02 AS 1684 SHALL BE APPLIED TO DOMESTIC CONSTRUCTION IN
U/S UNDERSIDE ADJACENT FOOTINGS OR EXCAVATIONS. 7.04 SLAB REINFORCEMENT SHALL EXTEND AT LEAST 75 mm ONTO MASONARY SHELTERED LOCATIONS.
GL GROUND LINE 5.10 DO NOT BACKFILL RETANING WALLS (OTHER THAN CANTELEVER WALLS) UNTIL FLOOR SUPPORT WALLS AND 50 PERCENT OF BOTTOM REINFORCEMENT SHALL BE COGGED 10.03 SOFTWOOD TO BE MINIMUM GRADE F7 U.N.O. HARDWOOD TO BE
FFL FINISHED FLOOR LEVEL CONSTRUCTION AT TOP AND BOTTOM IS COMPACTED.ENSURE FREE DRANING BACKFILL AND DRANAGE TO ACHIVE ANCHORAGE AT SIMPLY SUPPORTED ENDS. MINIMUM GRADE F14.
IN PLACE. 7.05 SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN POSITIONS SHOWN OR 10.04 EXTERNAL TIMBER TO BE EITHER HARDWOOD DURABILITY CLASS I
2.0 DESIGN DATA 5.11 FOOTINGS ARE TO BE CONSTRUCTED AND BACKFILLED AS SOON AS POSSIBLE FOLLOWING OTHERWISE APPOROVED IN WRITTING BY THE ENGINEER.LAPS SHALL BE IN OR II AS PER AS 1720.2 OR IMPREGNATED PINE GRADE F7,PRESSURE
2.01 THE STRUCTURAL COMPONENTS DETAILED ON THESE DRAWINGS HAVE EXCAVATION TO AVOID SOFTENING OR DRYING OUT BY EXPOSURE. ACCORDANCE WITH THE FOLLOWING: TREATED TO AS `604 AND RE-DRIED PRIOR TO USE.SUPPLEMENTARY
BEEN DESIGNED IN ACCORDANCE WITH THE RELEVANT STANDARDS AUSTRALIA5.12 FOR FOOTINGS FOUNDED ON CONTROLLED FILL REFER TO NOTE 4.04. FABRIC SHALL BE LAPPED SUCH THAT THE TWO OUTERMOST WIRES OF ONE SHEET TREATMENT SHALL BE APPLIED TO ALL OUT SURFACES,SUPPLY
OVERLAP THE TWO OUTERMOST WIRES OF THE OTHER SHEET BY 25 mm MINIMUM. SUPPORTING DOCUMENTATION FOR PRESERVATIVE TREATMENT.
CODES AND LOCAL GOVERNMENT ORDINANCES FOR THE FOLOOWING
LOADINGS,REFER TO ARCHITECTURAL DRAWINGS FOR PROPOSED FLOOR 6.0 CONCRETE A MAXIMUM OF THREE SHEETS OF FABRIC SHALL BE LAPPED AT ANY POINT. 10.05 TIMBER TRUSSES TO BE PRE-CAMBERED AN AMOUNT EQUAL TO
USAGE. 6.01 ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 3600 CURRENT EDITION DEAD LOAD DEFLECTION.THREE (3) COPIES OF SHOP DRAWINGS ARE TO
2.02 LIVE LOADS ARE IN ACCORDANCE WITH AS 1170.1 WITH AMENDMENTS,EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS. 8.0 STRUCTURAL MASONARY BE SUBMITTED TO THE ENGINEER FOR APPROVAL CLEARLY SHOWING
6.02 PRE-MIXED CONCRETE SUPPLY SHALL COMPLY WITH AS 1379. 8.01 ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 3700 THE DESIGN LOADS ON THE ROOF AND CEILING AND TRUSS NODE POINT
6.03 NO ADMIXTURES SHALL BE USED IN CONCRETE UNLESS APPROVED IN WRITING. CURRENT ADDITION WITH AMENDMENTS AND OTHER RELEVANT CODES. LOADS AND PRECAMBER.
6.04 CONCRETE MIX DESIGNS TO BE SUBMITTED FOR REVIEW PRIOR TO USE OF CONCRETE. 8.02 MORTAR ADMIXTURES SHALL NOT BE USED WITHOUT THE WRITTEN APPROVAL OF 10.06 ALL BOLTS IN TIMBER CONSTRUCTION TO BE MINIMUM M12 U.N.O.
FLOOR SUPERIMPOSED LIVE LOADS
6.05 ENSURE CLEAR COVER TO REINFORCEMENT IS AS FOLLOWING UNLESS DETAILED OTHERWISE. THE ENGINEER. BOLT HOLES TO BE DRILLED EXACT SIZE,WASHER UNDER HEADS AND
USAGE DEAD LOADS (kPa)
8.03 NON LOAD BEARING WALLS SHALL BE SEPERATED FROM CONCRETE ABOVE BY 25 NUTS TO BE AT LEAST 2.5 TIMES BOLT DIAMETER.
RESIDENTIA (kPa)
COVER (mm) mm GAP.PROVIDE JOINT FILLER TO THE ARCHITECT'S DETAILS. 10.07 TIMBER DIMENSIONS ON THE FINISHED WIDTH AND THICKNESS TO
L
-INTERNAL 0.50 1.50
FORMED FORMED-NOT NOT FORMED- 8.04 NO CHASES OR RECESSES ARE PERMITTED IN LOAD BEARING MASONARY BE:
-WET AREAS 1.00 1.50 ELEMENT EXPOSED TO EXPOSED TO CAST AGAINST I) SEASONED SOFTWOOD:5,-0 mm
WITHOUT THE APPROVAL OF THE ENGINEER.
-BALCONIES 0.50 2.00 WEATHER (B1) WEATHER (A1) GROUND II) UNSEASONEDSOFTWOOD : >F7:+3,-3mm OR F7:+2,-4mm
8.05 REINFORCED BRICKWORK SHALL COMPLY WITHT THE FOLLOWING U.N.O
I) FILL ALL BED JOINTS AND PERPENDS WITH MORTAR EXCEPT AT WEEP III) SEASONED HARDWOOD : +2,-0mm
FOOTINGS & PILES - - 20 IV) UNSEASONED HARDWOOD : +3,-3 mm
HOLES.
SLABS ON GROUND II) PROVIDE CLEAN-OUTS AT BASE OF REINFORCED CORES AND (SEE ALSO CLAUSE 1.6.2 IN AS 2082)
(TOP COVER) 40 20 - 10.08 ALL TIMBER JOINTS AND NOTCHES ARE TO BE 100 mm MINIMUM
2.03 WIND LOADS ARE IN ACCORDANCE WITH AS 1170.2-2002 AS FOLLOWS: CAVITIES.REMOVE MORTAR PROTRUSIONS BEFORE CORE OR CAVITY
REGIONAL WIND SPEED Vr = 46 m/s FILLING. AWAY FROM LOOSE KNOTS,SEVERE SLOPING GRAIN,GUM VEINS OR
ANNUAL PROBABILITY OF EXCEEDANCE = 1:1000 6.06 CONCRETE SIZES SHOWN DO NOT INCLUDE THICKNESSES OF APPLIED FINISHES. III) COMPACT GROUT FILLING BY RODDING OR MECHANICAL VIBRATOR. OTHER MINOR DEFECTS.
REGION : A2 6.07 DEPTHS OF BEAMS ARE GIVEN FIRST AND INCLUDE SLAB THICKNESS. IV) MAXIMUM HEIGHT OF POUR FOR CAVITY FILLED WALLS TO BE 1200 mm.
TERRIAN CATEGORY: 3 6.08 FOR CHAMFERS,DRIP GROOVES,RIGLETS ETC.REFER TO ARCHITECTURAL DETAILS,MAINTAIN COVER
2.04 THE CONCRETE ELEMENTS HAVE BEEN DESIGNED FOR THE FOLLOWING TO REINFORCEMENT AT THESE DETAILS. 8.06 WATERPROOF REAR FACE OF RETAINING WALLS AS SPECIFIED BY THE
EXPOURE CLASSIFICATIONS IN ACCORDANCE WITH AS 3600 6.09 NO HOLES,CHASES OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THE STRUCTURAL ARCHITECT. SITE PREPERATIONS
DRAWINGS SHALL BE MADE IN CONCRETE MEMBERS WITHOUT THE PRIOR WRITTEN APPROVAL OF THE 8.07 UNLESS NOTED OTHERWISE PROVIDE VERTICAL CONTROL JOINTS AT 12.0 m
ELEMENT CLASSIFICAION ENGINEER. CLEAR AREA UNDER SLAB OF ALL TOP SOIL CONTAINING HUMUS AND VEGETATABLE MATTER 100mm
MAXIMUM CENTRES AND 6.0 m FROM CORNERS IN ALL MASONARY WALLS U.N.O.
EXTERIOR CONCRETE S B1 6.10 CONSTRUCTION JOINTS WHERE NOT SHOWN SHALL BE LOCATED TO THE APPROVAL OF THE 8.08 BACKFILL TO RETAINING WALLS TO BE FREE DRAINING GRANNULAR MATERIAL MIN.
INTERNAL A1 ENGINEER. U.N.O.PROVIDE SUBSOIL DRAIN OR WEEP HOLES. PROVIDE FILL UNDER SLAB WHERE REQUIRED TO PRODUCE FINISHED LEVELS AS SHOWN ON PLANS.
CONCRETE 6.11 THE FINISHED CONCRETE SHALL BE A DENSE HOMOGENEOUS MASS COMPLETELY FILLING THE 8.09 ALL CAVITY CONSTRUCTION TO HAVE GALVANISED WALL TIES INSTALLED AS PER FILLING USED IN THE CONSTRUCTION OF A SLAB,EXCEPT WHERE THE SLAB IS SUSPENDED, SHALL
FORMWORK THOROUGHLY EMBEDDING THE REINFORCEMENT AND FREE OF STONE POCKETS,ALL CLAUSE 3.4 AND 4.10 AS 3700 CONSISTS OF CONTROLLED FILL ROLLED FILL AS FOLLOWS:
3.0 BULK EARTHWORKS CONCRETE INCLUDING SLABS ON GROUND AND FOOTINGS SHALL BE COMPACTED WITH MECHANICAL a) CONTROLLED FILL IS MATERIAL THAT HAS BEEN PLACED AND COMPACTED IN LAYERS BY
3.01 ALL EXCAVATION WORK TO BE CARRIED OUT TO THE SATISFACTION OF THEVIBRATORS. 9.0 STRUCTURAL STEELWORK COMPACTION EQUIPMENT WITHIN A DEFEND MOISTURE RANGE TO A DEFINED DENSITY
GEOTECHNICAL CONSULTANT INCLUDING INSPECTION OF STRIPPING APPROVAL6.12 CURING OF ALL CONCRETE IS TO BE ACHIEVED BY KEEPING SURFACES CONTINUOUSLY WET FOR A 9.01 ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH AS 4100 REQUIREMENT. EXCEPT AS PROVIDED BELOW, CONTROLLED FILL SHALL BE PLACED IN ACCORDANCE
OF FILL MATERIAL AND APPROVAL OF COMPACTION. PERIOD OF 3 DAYS AND PREVENTION OF LOSS OF MOISTURE FOR A TOTAL OF 7 DAYS FOLLOWED BY A EXCEPT WHERE VARIES BY THE CONTRACT DOCUMENTS. WITH AS3798.
3.02 REFER TO THE GEOTECHNICAL REPORT FOR EXCAVATION GRADUAL DRYING OUT,APPROVED SPRAYED ON CURING COMPOUNDS THAT COMPLY WITH AS 3799 MAY 9.02 UNLESS NOTED OTHERWISE,ALL STEEL SHALL BE IN ACCORDANCE WITH AS 3678 SAND FILL UP TO 0.8M DEEP, WELL COMPACTED IN NOT MORE THAN 0.3M THICK LAYERS BY A
CONDITIONS,INCLUDING NATURAL WATER LEVELS AND GROUND CONDITIONS. BE USED WHERE FLOOR FINISHES WILL NOT BE AFFECTED(REFER MANUFACTURER'S GRADE 250 OR AS 3679 GRADE 300,OR AS 1163 GRADE C350 AS APPROPRIATE. VIBRATING PLATE OR VIBRATING ROLLER SHALL BE DEEMED TO COMPLY WITH THIS REQUIREMENT. A
3.03 REFER TO SURVEY DRAWINGS FOR EXISTING SERVICES AND LEVELS. SPECIFICATION),POLYTHENE SHEETING OR WET HESSIAN MAY BE USED TO RETAIN CONCRETE 9.03 TWO (2) COPIES OF WORKSHOP FABRICATION DRAWINGS SHALL BE SUBMITTED SATISFACTORY TEST FOR SAND FILL NOT CONTAINING GRAVEL SIZED MATERIALIS THE ACHIEVEMENT
3.04 ALL LEVELS SHOWN ARE TO AUSTRALIAN HEIGHT DATUM. MOISTURE WHERE PROTECTED WIND AND TRAFFIC. TO THE ENGINEER FOR REVIEW AT LEAST 7 DAYS PRIOR TO COMMENCEMENT OF OF A BLOW COUNT OF 7 OR MORE PER 0.3M USING THE PENETROMETER TEST DESCRIBED IN AS
3.05 V.R.C INDICATES VERTICAL ROCK CUT,ROCK TO BE OUT NEAR VERTICAL 6.13 CONSTRUCTION SUPPORT PROPPING IS TO BE LEFT IN PLACE WHERE NEEDED TO AVOID FABRICATION.FABRICATION IS NOT TO COMMENCE WITHOUT ENGINEER'S APPROVAL AS1289.6.3.3. NON-SAND FILL UP TO 0.4M DEEP, WELL COMPACTED IN NOT MORE THAN 0.15M LAYERS
FROM LOWER BENCH AT 90 TO 95 DEGREE WITH HORIZON UNLESS NOTED OVERSTRESSING THE STRUCTURE DUE TO CONSTRUCTION LOADING.NO MASONARY OR PARTITION OF WORKSHOP DRAWINGS.ALL DIMENSIONS AND SETOUTS TO BE OBTAINED FROM BY A MECHANICAL ROLLER SHALL BE DEEMED TO COMPLY WITH THIS REQUIREMENT, CLAY FILL
OTHERWISE. WALLS ARE TO BE CONSTRUCTED ON SUSPENDED LEVELS UNTIL ALL PROPPING IS REMOVED AND THE ARCHITECTURAL DRAWINGS WHERE NOT INDICATED ON STRUCTURAL DRAWINGS. SHALL BE MOIST DURING COMPACTION.
3.06 OVERBURNDEN OCCURING ABOVE ROCK SHALL BE BATTERED BACK AT 2:1 SLAB HAS ABSORBED ITS DEAD LOAD DEFLECTION. 9.04 BOLT CATEGORY : COMMENTS b) ROLLED FILL CONSISTS OF MATERIAL COMPACTED IN LAYERS BY REPEATED ROLLING WITH AN
AS REQUIRED. 6.14 THE ENGINEER SHALL BE GIVEN24 HOURS NOTICE FOR REINFORCEMENT INSPECTION AND 4.6/S COMMERCIAL BOLTS OF GRADE 4.6 TO AS 1111SNUG EXCAVATIOR. ROLLED FILL SHALL NOT EXCEED 0.6M COMPACTED IN LAYER NOT MORE THAN 0.3M
3.07 SITE SURFACE CONTOURS SHOWN ARE INDICATIVE ONLY,FOR TRUE CONCRETE SHALL NOT BE DELIVERED UNTIL FINAL APPROVAL OBTAINED. TIGHTENED THICK FOR SAND MATERIAL OR 0.3M COMPACTED IN LAYERS NOT MORE THAN 0.15M THICK FOR
SURFACE LEVELS REFER SURVEY DRAWINGS. 6.15 CONDUITS PIPES ETC SHALL ONLY BE LOCATED IN THE MIDDLE THIRD OF THE SLAB DEPTH,PIPES OR 8.8/S HIGH STRENGTH STRUCTURAL BOLTS OF GRADE 8.8 TO AS OTHER MATERIAL.
4.0 SLAB ON GROUND CONDUITS SHALL NOT BE PLACED WITHIN THE COVER TO REINFORCEMENT. 1252 SNUG TIGHTENED A 50mm MIN. BASE COURSE OF PACKING SAND SHALL BE SPREAD OVER THE SUB-BASE AND TO BE
4.01 REMOVE ALL TOP SOIL INCLUDING ROOTS AND ANY OTHER ORGANIC 6.16 SLABS AND BEAMS SHALL BE CONSTRUCTED TO BEAR ONLY ON THE BEAMS,WALLS COLUMNS ETC 9.05 UNLESS NOTED OTHERWISE ALL CLEAT PLATES SHALL BE MINIMUM 10 mm THICK. THOROGHLY ROLLED AND COMPACTED TO A SMOOTH LEVEL SURFACE. THE SAND SHALL BE
MATTER,STORE TOP SOIL AS REQUIRED. SHOWN ON THE DRAWINGS.ALL OTHER BUILDING ELEMENTS SHALL BE KEPT 20 mm MINIMUM CLEAR 9.06 UNLESS NOTED OTHERWISE ALL BOLTS SHALL BE M20 CATEGORY 8.8/S,NO MOISTENED PRIOR TO THE PLACEMENT OF A 0.2mm POLYTHENE MEMBRANE IN 360mm MIN. WIDE
4.02 WHERE SHOWN ON THE DRAWINGS,BASE AND SAND BUNDING ARE TO BE FROM SOFFITS OF STRUCTURE. CONNECTION SHALL HAVE LESS THAN 2 BOLTS. ALL BOLTS,NUTS AND WASHERS SHALL SHEETS LAPPED 150mm AND JOINED WITH 75mm WIDE PRESSURE SENSITIVE TAPE. THE TAPE SHALL
PLACED AND COMPACTED AS SPECIFIED. 6.17 CONCRETE QUALITY SHOWN IN CONCRETE MIX DESIGN TABLE. BE HOT DIPPED GALVANISED,UNLESS NOTED OTHERWISE.ALL HOLDING DOWN BOLTS BE LAID UNDER ALL SLABS AND WALLS IN CONTACT WITH THE GROUND.
CONCRETE MIX TABLE THE TOTAL FILL BENEATH THE SLAB PANELS MUST NOT EXCEED 300MM.i.e. THE SUM OF EXISTING FILL
4.03 EXCAVATE TO THE REQUIRED FORMATON LEVEL AND PROOF ROLL SHALL BE M20 CATEGORY 4.6/S. ALL BOLTS,NUTS AND WASHERS SHALL BE HOT DIPPED
FORMATION WITH 6 PASSES OF A 10 TONNE SMOOTH WHEELED ROLLER,SOFT EXPOSURE STRENGTH (MPa) GALVANISED. PLUS ANY NEW FILLING PLACED TOGETHER MUST NOT EXCEED 300mm MAX.
AREAS ARE TO BE REMOVED AND REPLACED WITH SUITABLE FILL COMPACTED CLASSIFICATION U.N.O 9.07 FABRICATION SHALL COMPLY WITH AS 4100,SECTION 14. OVER THE PROPOSED BUILDING AREA, BUILDER TO REMOVE ALL TREES AND TREE ROOTS/MATERAIL.
TO THE DENSITY NOMINATED BELOW. ELEMENT (AS 3600) Pc AT 28 COVER 9.08 ERECTION SHALL COMPLY WITH AS 4100 SECTION 15. ANY SOFT OR LOOSE MATERIAL THAT DOES NOT RESPOND TO COMPACTION SHOULD BE EXCAVATED TO
4.04 CONTROLLED FILL MATERIAL SHALL MEET THE REQUIREMENTS OF THE DAYS 9.09 UNLESS NOTED OTHERWISE,ALL FILLET WELDS SHALL BE 6 mm CONTINUOUS ACHIEVE A FIRM WORKING BASE. FILL HOLES WITH NON POROUS FILL COMPACTED IN 150mm MAX.
GEOTECHNICAL REPORT,PLACE IN MAXIMUM 150mm.THICK LAYERS TO 98% FOOTINGS A1 25 50 CATEGORY GP USING E41XX ELECTRODES.ALL BUT WELDS SHALL BE COMPLETE LAYERS.
STANDARD COMPACTION IN ACCORDANCE WITH AS 1289E1.1 MAXIMUM DEPTH WALLS/COLUMNS INTERNAL A1 32 40 PENETRATION BUTT WELDS CATEGORY SP TO AS 1554.1. UNLESS NOTED OTHERWISE
OF FILL IS TO BE 400 mm FOR COHESIVE FILL AND 800 mm FOR GRANULAR FILL. WALLS/COLUMNS EXTERNAL B1 32 40 ALL PURLIN CLEAT WELDS SHALL BE 6 mm CONTINUOUS CATEGORY GP USING E41XX
4.05 CLAY SUBGRADE FORMATION IS TO BE MAINTAINED AT OPTIMUM MOSTURE ELECTRODES.
CONTENT -O,+3% PRIOR TO COVERING. SLABS ON GROUND A1 25 40 9.10 PROVIDE SEAL PLATES TO THE ENDS OF ALL HOLLOW SECTIONS,WITH 'BREATHER'
INTERNAL SUSPENDED SLABS A1 32 40 HOLES IF MEMBERS TO BE HOT DIP GALVANISED.
EXTERNAL SUSPENDED SLABS B1 9.11 STRUCTURAL STEELWORK NOT ENCASED IN CONCRETE SHALL HAVE THE
32 40
FOLLOWING SURFACE TREATMENT IN ACCORDANCE WITH THE SPECIFICATION.
PILES A1 25 75

Sheet Title :
RASMAN Pty.Ltd. No. Description Date CLIENT:
BASANA K C & SAGAR SILWAL
Project Status : VERIFICATION:
DO NOT SCALE THE DRAWINGS,READ ALL DIMENSIONS
SHOWN ALL DIMENSIONS,NOTES ON PLAN & CONSENT
ABDULALLH ALLK Civil/Structure P. Eng. 1 Revision 1 Date 1 STRUCTURAL GENERAL Project Status DOCUMENTS MUST BE CHECKED & VERIFIED BY THE
M.I.E (Aust.) 3281602 NOTES CONTRACTOR PRIOR TO ANY COMMENCEMENT OF
13 Greendale Cr. Chester hill NSW 2162 PROJECT: PROJECT: Project Number
BUILDING WORKS ON SITE TO CLARIFY ANY
DISCRIPANCIES BETWEEN ALL PLAN DRAWINGS &
Mobile 0406 674 982 SHEET NO : DOCUMENTATION RELEVANT TO THE PROPOSAL,SITE
LOT 2129 (No. 41) - DP 1236712 DATE: 08/25/20 WORKS,GROUND LEVELS MAY VARY DUE TO SITE
CONDITIONS.
COPY RIGHT: THIS DRAWING IS THE PROPERTY OF
RASMAN Pty Ltd CREATED BY GRID DRAFTING
PROJECT ADDRESS: DRAWN BY: PG MIEAust 4406526 S01
a.allk@yahoo.com, SERVICES AND MAY NOT BE RETAINED,COPIED IN FELLING STREET DESIGNED BY: PG MIEAust 4406526
WHOLE OR IN PART OR USED OTHER THAN FOR THE SCALE : REVISION :
ACN 22126810273 SPECIFIC USE,LICENSED AND ISSUED WITHOUT THE BOX HILL - ALBERT PARK PROJECT CHECKED BY: ALLK. MIEAust 3281602
WRITTEN CONSENT OF BOTH PARTIES.
APPROVED BY: Approver
As indicated No
Top of Wall R.L =46.01
Top of Wall R.L =46.01

10254

Existing
Ground
3065

Existing
Bottom of wall R.L = 45.31 Ground

Section1 Bottom of wall R.L =


45.31
4 1 : 50
Section2
5 1 : 50

Top of Wall R.L =46.01


21303 270
22522

28631

Top of Wall R.L =46.01 270 CONCRETE WALWAY AT


REAR TO ACCESS AT REAR
GROUND
LEVEL
270 mm WIDE GROUND LEVEL
DOUBLE BRICK WALL

270 mm WIDE DOUBLE


110 mm WIDE BLOCK BRICK WALL
WALL FILLED SOLID
CONCRETE
SLAB
100 DIA TILE DRAIN TO
SOAKAWAY

CONCRETE SLAB

Drafting 1 RETAINING WALL SECTION DETAIL


1609 7747 2041 2 1 : 50 3 1 : 50

Existing Ground
1 1 : 200

Sheet Title :
RASMAN Pty.Ltd. No. Description Date CLIENT:
BASANA K C & SAGAR SILWAL
Project Status : VERIFICATION:
DO NOT SCALE THE DRAWINGS,READ ALL DIMENSIONS
SHOWN ALL DIMENSIONS,NOTES ON PLAN & CONSENT
ABDULALLH ALLK Civil/Structure P. Eng. Retaining Wall Project Status DOCUMENTS MUST BE CHECKED & VERIFIED BY THE
M.I.E (Aust.) 3281602 CONTRACTOR PRIOR TO ANY COMMENCEMENT OF
13 Greendale Cr. Chester hill NSW 2162 PROJECT: PROJECT: Project Number
BUILDING WORKS ON SITE TO CLARIFY ANY
DISCRIPANCIES BETWEEN ALL PLAN DRAWINGS &
Mobile 0406 674 982 SHEET NO : DOCUMENTATION RELEVANT TO THE PROPOSAL,SITE
LOT 2129 (No. 41) - DP 1236712 DATE: 06/27/22 WORKS,GROUND LEVELS MAY VARY DUE TO SITE
CONDITIONS.
COPY RIGHT: THIS DRAWING IS THE PROPERTY OF
RASMAN Pty Ltd CREATED BY GRID DRAFTING
PROJECT ADDRESS: DRAWN BY: Author S02
a.allk@yahoo.com, SERVICES AND MAY NOT BE RETAINED,COPIED IN FELLING STREET DESIGNED BY: Prakash Giri
WHOLE OR IN PART OR USED OTHER THAN FOR THE SCALE : REVISION :
ACN 22126810273 SPECIFIC USE,LICENSED AND ISSUED WITHOUT THE BOX HILL - ALBERT PARK PROJECT CHECKED BY: Checker
WRITTEN CONSENT OF BOTH PARTIES.
APPROVED BY: Approver
As indicated No
Top of Wall R.L =47.51

Top of Wall R.L =45.91

47.51

46.01 45.91

1500
Existing

600
Ground

Bottom of wall R.L = 45.31


Bottom of wall R.L = 45.31

Section X-X
1 1 : 75
47.51

Top of Wall R.L = 48.01

1500
47.51

46.01 45.91
Existing
700

Ground

Bottom of wall R.L = 45.31

Section Y-Y
2 1 : 100

Sheet Title :
RASMAN Pty.Ltd. No. Description Date CLIENT:
BASANA K C & SAGAR SILWAL
Project Status : VERIFICATION:
DO NOT SCALE THE DRAWINGS,READ ALL DIMENSIONS
SHOWN ALL DIMENSIONS,NOTES ON PLAN & CONSENT
ABDULALLH ALLK Civil/Structure P. Eng. Retaining Wall sections Project Status DOCUMENTS MUST BE CHECKED & VERIFIED BY THE
M.I.E (Aust.) 3281602 CONTRACTOR PRIOR TO ANY COMMENCEMENT OF
13 Greendale Cr. Chester hill NSW 2162 PROJECT: PROJECT: Project Number
BUILDING WORKS ON SITE TO CLARIFY ANY
DISCRIPANCIES BETWEEN ALL PLAN DRAWINGS &
Mobile 0406 674 982 SHEET NO : DOCUMENTATION RELEVANT TO THE PROPOSAL,SITE
LOT 2129 (No. 41) - DP 1236712 DATE: 06/28/22 WORKS,GROUND LEVELS MAY VARY DUE TO SITE
CONDITIONS.
COPY RIGHT: THIS DRAWING IS THE PROPERTY OF
RASMAN Pty Ltd CREATED BY GRID DRAFTING
PROJECT ADDRESS: DRAWN BY: Author S03
a.allk@yahoo.com, SERVICES AND MAY NOT BE RETAINED,COPIED IN FELLING STREET DESIGNED BY: Designer
WHOLE OR IN PART OR USED OTHER THAN FOR THE SCALE : REVISION :
ACN 22126810273 SPECIFIC USE,LICENSED AND ISSUED WITHOUT THE BOX HILL - ALBERT PARK PROJECT CHECKED BY: Checker
WRITTEN CONSENT OF BOTH PARTIES.
APPROVED BY: Approver
As indicated No