52DK Fuling inverter can be programmed to control three different
spindles on a CNC router. The programming involves setting various parameters to configure the inverter's behavior. Below is an explanation of the functions and sub-functions from 00 to 30 for F3 to F8.
Function F3: Operation Control Parameters
Sub-function 00: Acceleration Time (ACC)
This parameter determines the time taken by the spindle to accelerate from a stopped state to its maximum speed. It is set in seconds. Sub-function 01: Deceleration Time (DEC) This parameter determines the time taken by the spindle to decelerate from its maximum speed to a stopped state. It is set in seconds. Sub-function 02: Jog Acceleration (J-ACC) This parameter sets the acceleration time for jogging the spindle. Jogging refers to manually controlling the spindle speed. It is set in seconds. Sub-function 03: Jog Deceleration (J-DEC) This parameter sets the deceleration time for jogging the spindle. It is set in seconds. Sub-function 04: Frequency Upper Limit (F-H) This parameter sets the maximum operating frequency for the spindle. It is set in Hertz. Sub-function 05: Frequency Lower Limit (F-L) This parameter sets the minimum operating frequency for the spindle. It is set in Hertz. Sub-function 06: Voltage Upper Limit (U-H) This parameter sets the maximum output voltage for the spindle. It is set in volts. Sub-function 07: Voltage Lower Limit (U-L) This parameter sets the minimum output voltage for the spindle. It is set in volts. Sub-function 08: Motor Rated Voltage (U-R) This parameter specifies the rated voltage of the spindle motor. It is set in volts. 10. Sub-function 09: Motor Rated Current (I-R) This parameter specifies the rated current of the spindle motor. It is set in amperes.
Function F4: Running Parameters
11. Sub-function 00: Voltage Boosting (U-Boost)
This parameter determines the voltage boosting level during spindle operation. It is set as a percentage. 12. Sub-function 01: Dynamic Braking Time (DB-Time) This parameter sets the time for dynamic braking, which helps quickly stop the spindle. It is set in seconds. 13. Sub-function 02: Dynamic Braking Voltage (DB-Voltage) This parameter sets the voltage level used for dynamic braking. It is set as a percentage of the maximum output voltage.
Function F5: Control and Protection Parameters
14. Sub-function 00: Control Method Selection (CTRL)
This parameter selects the control method for the spindle. Options may include V/F control or vector control. 15. Sub-function 01: Overvoltage Protection Level (OVP) This parameter sets the level at which overvoltage protection is activated.