You are on page 1of 1

5 4 3 2 1 Client:

1800
LIFTINGHOOK

200
Consultant:

500
TRANSFARMER

1500
200
Notes:

400
LT VAR. 4000 TO 4500
VAR.
VAR. 1500 TO 1670 100

200
100 VAR. 1800 TO 2400 130 TO 500
D D
VAR. 1800 TO 2400 VAR. 1500 TO 1800
VAR. 1800 TO 2400
PLAN 200 400
VAR. 500 TO 800
200 200

200 200
LIFTINGHOOK 200 VAR. 1400 TO 2000 200

200
VAR. 500 TO 800
1500

300

300
1800 G.L G.L G.L

VAR. 1500 TO 1800


VAR. 1500 TO 1800
200 1400 200 200 400 200 500 200 TRANSFORMER

500
TRANSFORMER

200
300

300

2000

200

800
G.L

800
G.L G.L
CABLE

600
RMU CABLE ENTRY
ENTRY

1100

400
4Ways LT

400
LT

800
800

200
100200
CABLE ENTRY CABLE
600

ENTRY
PLAN FRONT VIEW SIDE VIEW
LIFTINGHOOK
Note:
FRONT VIEW SIDE VIEW CEMENT 350KG/M³
CONCRETE COMPRESIVE STRENGTH 300KG/CM²
SOIL BEARING CAPICITY 150KN/M²

FIG 02: PLAN & SIDE VIEWS FOR FOUNDATION OVER ALL PLAN FOR FOUNDATION FIG 02: PLAN & SIDE VIEWS FOR FOUNDATION
300/500 KVA UNIT SUBSTATION OF UNIT SUBSTATION OF UNIT SUBSTATION

B
VAR. 1800 TO 2400
200 1400 200
2-12 DIA 200mm
VAR. 1500 TO 1800
200

STIRRUPS C/C (TYPE)


10 DIA 150 mm
C/C (TYPE)
VAR. 1500 TO 1800

G.L
821,27
200

2188,63
TO 800

C A A C
1640,42

CABLE
600

ENTRY 4000
400
200 500

100 1800 500 1500 100


VAR.

200 200 400


200

C C VAR. 500 TO 800


STIRRUPS
10 DIA 150 mm 2-12 DIA 200mm SECTION B-B
C/C (TYPE) PLAN B C/C (TYPE)
200
200

200 VAR. 1400 TO 2000 200 2-12 DIA 200mm


STIRRUPS VAR. 1800 TO 2400 C/C (TYPE)
500

10 DIA 150 mm TRANSFARMER


C/C (TYPE)
UNIT SUBSTATION RATINGS OVERALL DIMENSIONS IN (mm)
1700

MV TERMINATION
300

1500
2000

G.L G.L BOX


200

RMU

1100
TRANSFORMER
Ways KVA LOAD VOLTAGE (V) LENGTH WIDTH HEIGHT
1100

400

LT
800

600

2-12 DIA 200mm


500 400/230 4000 2000 2200
200

C/C (TYPE) LV COMPARTMENT


100

WIDTH (W)
General Key Plan:
1000 400/230 4000 2000 2200

NO E
RTH
200 200

TRU
STIRRUPS
10 DIA 150 mm
C/C (TYPE) SECTION A-A SECTION C-C LIFTINGHOOK PACKAGE SUBSTATION ENCLOSURE

QIBLA
Note: 1500 400/230 4500 2000 2200
CEMENT 350KG/M³
CONCRETE COMPRESIVE STRENGTH 300KG/CM²
SOIL BEARING CAPICITY 150KN/M²
LIFTING LUG (HOT DIP GALVANIZED)
DIA 16mm CAR WASH

FIG 03: REINFORCEMENT DETAILS FOR FOUNDATION OVER ALL PLAN FOR FOUNDATION SEC UNIT SUBSTATION COMPONENT LAYOUT UNIT SUBSTATION DIMENSIONS
OF UNIT SUBSTATION UNIT SUBSTATION AS PER 56-SDMS-01-REV1

Project Name:
B B

FINISHED ROAD LEVEL FINISHED ROAD LEVEL FINISHED ROAD LEVEL Tas'helat Retail Fuel Service
Stations in Central and
Eastern Regions
Project Number S0006-0100D

ROAD CONSTRUCTION LAYER ROAD CONSTRUCTION LAYER ROAD CONSTRUCTION LAYER

FINISHED GROUND LEVEL TENDER DESIGN


MAY 2021

180 WARNING TAPE SOIL BACKFILL SOIL BACKFILL SOIL BACKFILL

BACKFILL
800mm 200 Ø 100 mm UVPC DUCT Ø 100 mm UVPC DUCT Ø 100 mm UVPC DUCT
TYPICAL TYPICAL TYPICAL

SOIL SOIL SOIL


0 31-05-2021 TENDER DESIGN G.S.
Rev Date Description Appr
100

PLASTIC SPACER PLASTIC SPACER PLASTIC SPACER Issue:

100
CABLE
FILE NAME S20006-0100D-PK006-R0015-GN000-TD-EG-508
: REV 0

MODEL NAME -:

100 FINE SAND DRAWN BY: N.K.

DESIGN BY: A.S./N.G./E.H./A.C.

CHECKED BY: I.R.


APPROVED BY: G.S.

150mm 300mm 150mm

A A Sheet Title

MISCELLENIOUS
DETAILS
MV TRENCH CONFIGURATION (2 CABLES)
LOW VOTAGE UPVC LOW VOTAGE UPVC LOW VOTAGE UPVC
300mm TRENCH WIDTH DUCTS IN SOIL DUCTS IN SOIL DUCTS IN SOIL
4x100mm 6x100mm 8x100mm Sheet No.
PLOT BUILDING
PHASE PACKAGE ZONE LEVEL
NUMBER CODE

TD PK006 0015 GN000 R -

EG-508 1OF1
5 4 3 2 1

You might also like