ODOVTOS
BASIC RESEARCH DOI: 10.15517/IJDS.2022.52970
Received:
12-VII-2022
Depth of Cure, Mechanical Properties and Morphology of
Accepted:
Dual-Cure Bulk-Fill Composites
14-X-2022
Ayca Sarialioglu Gungor DDS¹; Ali Durmus PhD²; Belma Zengin Kurt PhD³;
Safiye Selin Köymen DDS⁴; Nazmiye Dönmez DDS, PhD⁵
ABSTRACT: This study evaluated selected structural and physical properties, such as
degree of conversion (DC), Vickers hardness (VHN), and compression strength (CS), of
three new dual-cure bulk-fill resin-based composites (RBCs; ACTIVA, HyperFIL, and
Fill-Up) and compared them to those of a conventional RBC (Filtek Z250) at three
clinically relevant depths. Samples (n=180) were prepared in three depths (2,4, and
6mm). Fourier-transform infrared spectroscopy (FTIR) analysis and VHN and CS tests
were performed. The DC value was calculated by considering the relative change
in the aliphatic C=C peaks. The fractured surfaces of representative samples were
characterized using scanning electron microscopy (SEM). Data were statistically
evaluated using two-way analysis of variance and post hoc Bonferroni tests (p<0.05).
According to the VHN results, Filtek Z250 showed the highest bottom/top hardness ratio
(97.94±1.01) at 2mm thickness and ACTIVA showed the lowest bottom/top hardness
ratio (43.48±5.64) at 6mm thickness (p<0.001). According to the FTIR results, the DC
decreased with increasing thickness in all materials (p<0.05). Filtek Z250 showed the
highest (301±12.4 MPa) and ACTIVA exhibited the lowest (232±17.2 MPa) CS values
at 2mm thickness (p<0.05). The lowest CS values were obtained for ACTIVA, and the
highest values were obtained for Filtek Z250 for samples with thicknesses of 4 and
SARIALIOGLU A., DURMUS A., ZENGIN B., KÖYMEN S.S., DÖNMEZ N., 2023: Depth of Cure, Mechanical Properties and Morphology of Dual-Cure
Bulk-Fill Composites.-ODOVTOS-Int. J. Dental Sc., 25-1 (January-April): 72-87.
ODOVTOS-Int. J. Dent. Sc. | No. 25-1: 72-87, 2023 | ISSN: 2215-3411. 72
Sarialioglu et al: Depth of Cure, Mechanical Properties and Morphology of Dual-Cure Bulk-Fill Composites
cal properties or compromising the quality of the activation (21). While light irradiation enables
restored teeth (7). In addition, the shorter operation rapid initiation of polymerization on the surface
times associated with bulk-fill RBCs are regarded and to a certain depth and stabilizes restorations,
as a positive factor in the selection of products polymerization proceeds at a much slower rate
for clinical use (8). However, it has been reported deeper in the composite due to insufficient light
that light-cured bulk-fill RBCs possess insufficient penetration (21). To the best of our knowledge,
polymerization for thicker applications, which can to date, few studies have examined the polyme-
significantly affect the clinical success of restorations rization characteristics and mechanical properties
due to increased cytotoxicity (9), decreased hardness of these dual-cure bulk-fill RBCs. In addition, it
(10), and sensitivity to marginal defects (11). is essential to investigate how composite thick-
ness affects mechanical parameters such as
RBCs used in dental restoration harden compression strength (CS) and Vickers hardness
during the polymerization process. This invol- (VHN). According to several studies (1-3,5,10,15),
ves many small molecules (monomers) combining these properties may be connected to the DC of
to form macromolecules via a series of chemical the material and, as a result, may be diminished
reactions; in short, it is the conversion of monomers at the deeper levels of an increment. Moreover,
into polymers (12). A key parameter used to the properties of dual-cured restorative materials
quantify polymerization reactions is the degree of should be compared to those of light-cured
conversion (DC), which corresponds to the conver- materials to establish whether their performance
sion ratio of carbon-carbon double bonds (C=C) is sufficient and appropriate for clinical use.
to carbon-carbon single bonds (C-C) to form the
polymeric network (13). This chemical reaction is Therefore, the aim of this study was to
known as crosslinking and is theoretically charac- evaluate the DC, CS, and bottom/top VHN values
terized by the formation of a rigid structure with of three new dual-cure bulk-fill RBCs and compare
infinite molecular weight and viscosity. A high DC them to a conventional light-cure RBC at various
value is an essential structural feature for impro- application depths: 2,4, and 6mm. The following
ving the mechanical properties, chemical stabi- null hypotheses were tested: 1) regardless of the
lity, and durability of dental restorations (14,15). material, the DC does not significantly decrease as
Incomplete monomer conversion not only leads to the increment thickness increases, 2) the bottom/top
premature damage to restorations and secondary VHN ratio of the tested materials does not significantly
caries (16), but also to monomer elution, which decrease as the increment thickness increases, and
is considered the cause of undesirable biological 3) the CS of the tested materials does differ signi-
reactions, such as cytotoxicity and inflammation of ficantly as the thickness increases.
the pulp tissue (17). In addition, residual monomers
in the composite structure may change the color of MATERIALS AND METHODS
the composite and deteriorate its long-term struc-
tural properties via oxidation (18,19). SAMPLE SIZE CALCULATION
As paste-paste fluid materials, dual-cure The power of the sample size (n=180) was
bulk-fill resin composites have recently been calculated using G*Power software (version 3.1,
presented (20) with the objective of decreasing Heinrich-Heine Dusseldorf University, Dusseldorf,
the light attenuation effects by using chemical Germany) with a 95% confidence interval, 80%
power, and 0.50 effect size values according to used as the test materials: a flowable dual-cure
one-way analysis of variance (ANOVA)-type power bulk-fill composite (Fill-Up, Coltène/Whaledent
analysis. The minimum sample size was calculated AG, Altstätten, Switzerland), a bioactive flowa-
to be 15 specimens per group. ble dual-cure bulk-fill composite (ACTIVA BioAc-
tive Restorative, Pulpdent Corp., Watertown, MA),
COMPOSITE MATERIALS and a low-viscosity dual-cure bulk-fill composite
(HyperFIL HAp, Parkell Inc., New York, USA). The
In this study, four commercially available chemical compositions and lot numbers of the
dental restorative materials were evaluated. A composites, as well as the particle sizes of their
conventional RBC was used as the control material inorganic components, are shown in Table 1, and
(Filtek Z250, 3M ESPE, St. Paul, MN). The following the information is based on the data sheets provi-
three dual-cure bulk-fill composite materials were ded by the manufacturers.
Filtek Z250 20s Light-cure BisGMA, UDMA, and BisEMA Zirconia/silica particles 0.01-3.5μm 22
(3M Espe, St. Paul, microhybrid resin 82 wt%
MN, USA) composite
(N993561)
*BisEMA: bisphenol A ethoxy dimethacrylate; BisGMA: bisphenol A glycidyl methacrylate; BPO: dibenzoyl peroxide; DUDMA: Diurethane
dimethacrylate; HEMA: 2-hydroxyethyl methacrylate; MPAA: Modified polyacrylic acid; TEGDMA: triethylene glycol dimethacrylate; TMDPO:
(2,4,6-trimethylbenzoyl) diphenylphosphinoxide; TMPTA: trimethylolpropane triacrylate; TMPTMA: trimethylol propane trimethacrylate;
UDMA: urethane dimethacrylate.
are presented. The mechanical parameters of the ber range of 1,550-1,775 cm-¹ and the C=C
samples were determined from typical stress- double-bond region (1,590-1,660 cm-¹), respec-
strain curves obtained from the compression tests. tively. Figure 2.a shows the peaks of aliphatic and
aromatic C=C bonds in an uncured representa-
FRACTURE SURFACE ANALYSIS BY SCANNING tive sample (Filtek Z250). The FTIR transmittance
ELECTRON MICROSCOPY (SEM) spectrum of samples was deconvoluted into two
peaks by a Lorentzian function after performing
The fracture surfaces of representative a linear baseline correction in a wavenumber
samples (n=2/group) were examined using scanning range of 1,590-1,660 cm-¹. Areas of 1,608 cm-¹
electron microcopy (SEM) (Hitachi SU3500 T2, and 1,637 cm-¹ peaks were determined with the
Hitachi Corp., Tokyo, Japan). The size, geometry, peak deconvolution operation using OriginPro 8.0
and distribution of the inorganic particles in the software. A change in peak intensity at 1,637 cm-¹
organic matrix were observed. Prior to SEM analy- due to crosslinking is illustrated in Figure 2.b.
sis, all samples were coated with a 10nm thin Figure 2.c compares the calculated DC% values of
gold film under vacuum using the SC7620 Mini the samples as a function of sample thickness. It
Sputter Coater (Quorum, East Sussex, UK) to make was found that the DC% values decreased in the
the samples conductive. After the compression order of ACTIVA>HyperFIL>Filtek Z250>Fill-Up for
test, the cracked surfaces of the samples were sample thicknesses of 2mm and 4mm. For the 6
photographed directly using the high-pressure mm-thick samples, this order was HyperFIL>Filtek
method at 20kV and a working distance of 10mm Z250≥ACTIVA>Fill-Up.
at 1,500× and 5,000× magnifications.
STATISTICAL ANALYSIS
RESULTS
DC
Figure 1.a and Figure 1.b show the FTIR Figure 1. FTIR spectrum of uncured composites in the wavenumber
spectra of the uncured composites in the wavenum- range of (a) 1550-1775 cm-1 and (b) C=C double bond region.
COMPRESSION TEST
the Filtek Z250 composite at different thicknes- lines that appeared in the 6-mm thickness ACTIVA
ses, and the images taken at a lower magnifica- sample. Vertical and deep cracks that fragmented
tion were used to determine the failure mechanism the specimen into several big pieces are clearly
of the composites. Figure 7.d shows the fracture seen in this image.
Figure 3. Representative photographs of (a) test specimens with a thickness of 2, 4, and 6mm, (b) compression test device, and (c) a
cracked composite sample after compression test.
Figure 4. (a) A typical stress-strain behavior of samples obtained from compression test. The characteristic mechanical parameters of
samples (i) “elastic (or compressive) modulus,” which is a slope of the SS curve, and (ii) “CS,” which is a maximum stress value before
failure and “strain at failure” under compressive loads are defined on the SS curves. (b) Comparing the CS values of samples as a function
of composite type and thickness.
Figure 5. SEM images of composites with a magnification of x1500. (a) Filltek Z250, (b) Fill-Up, (c) HyperFIL, and (d) ACTIVA.
Figure 6. SEM images of composites with a magnification of x5000. (a) Filltek Z250, (b) Fill-Up, (c) HyperFIL, and (d) ACTIVA.
Figure 7. Comparing the fractured regions of composites (a) Filltek Z250 (2mm and magnification of x250), (b) Filltek Z250 (4mm and
magnification of x250), (c) Filltek Z250 (6mm and magnification of x55), and (d) ACTIVA (6mm and magnification of x55).
Fill-Up, despite the resin content of HyperFIL Sideridou et al. (34) reported that the DC of
(25-30 wt%) being lower than that of Fill-Up (35 light-cured dimethacrylate-containing RBCs was
wt%), according to the data sheet information affected by their chemical components, and that
listed in Table 1. This may be related to the higher the DC increased in the order of Bis-GMA<Bis-
reactive group content of the HyperFIL composite EMA<UDMA<TEGDMA. However, the ratio of filler
resin. Moreover, HyperFIL was photoactivated for 40 amount to resin is also important for polymeriza-
s, resulting in a total radiant exposure of 44 J/cm². tion. As the amount of filler increases, it becomes
This may have contributed to a higher DC% (31). more difficult for the composite to polymerize (35).
Increasing the amount of filler prevents polymeric
The second null hypothesis-that the bottom/ chain propagation (36) and reduces the mobility
top VHN ratio of the tested materials does not of Bis-GMA due to its high viscosity (34). Hence,
significantly decrease as the increment thickness in our study, the finding that ACTIVA showed the
increases-was partially rejected. The thickness highest DC% at thicknesses of 2 and 4mm (Figure
of the layers in which the composite resin must 2) can be attributed to it containing a low amount
be applied is important to achieve an acceptable of filler.
DC (32). When the microhardness measurement
method is used, the DC of a composite resin is The third null hypothesis, that the CS of the
determined by the ratio of the bottom/top surfaces tested materials differs significantly as the thick-
microhardness values. In the literature, a bottom/ ness increases, was also rejected. The mechanical
top surface ratio of 80-90% is stated as a clinica- parameters of restorative composites obtained from
lly acceptable degree of curing (33). According to typical low-speed compression tests have been
our results, as the thickness increased from 2mm previously defined in detail (37) and can be found
to 6mm, the DC%, bottom/top ratios of VHN, and elsewhere (38,39). CS is regarded as the most
CS values of all samples decreased. The bottom/ important mechanical property of dental restora-
top VHN ratio of Filtek Z250 at a thickness of 6mm tive materials because it directly represents the
showed the highest value when compared to the mechanical durability and long-term performance
other bulk-fill composite resins (98.17±2.4; Table of a material under loading conditions. Poiate et
2). This may be because it was polymerized using al. reported the standard and maximum masti-
the conventional method at the 2-mm thickness. catory forces on adult posterior teeth as 100 N
When the Filtek Z250 composite resin content and 235.9 N, respectively (40). Many studies have
was examined, it was found that a large amount reported on the force distribution on the occlusal
of TEGDMA had been replaced by UDMA and points and associated stresses on posterior teeth
Bis-EMA. We think that the increased amount of (41-43). The CS and mechanical performance of
UDMA monomer in the structure of the composite a dental restorative composite depend on many
resin was also a factor that contributed to the high parameters, such as (i) the composite composition,
DC. The UDMA monomer shows a higher DC% than (ii) the interfacial interaction between the organic
the Bis-GMA monomer due to its relatively high resin and the inorganic particles, (iii) the geometry,
molecular weight, double-bond concentration, and size, and size distribution of the inorganic parti-
low viscosity. The fact that the bottom/top surface cles, (iv) the curing procedure, and (v) the post-
VHN values of the ACTIVA samples prepared at curing treatments. It is generally accepted that the
thicknesses of 2, 4, and 6mm were less than 80% composite composition (specifically the number
may be because ACTIVA does not contain UDMA of inorganic particles), the curing procedure (e.g.,
and Bis-GMA monomers. the light source’s power and wavelength and the
irradiation time), and other related features (e.g., structures. Our finding that ACTIVA demonstrated
the DC in the resin matrix and the shrinking ratio) a higher DC% than Filtek Z250 aligns with the
greatly influence the success of a filling operation results of Leprince et al. (46).
and the life of filling materials. Although no statisti-
cal difference was found between the values, in our The images shown in Figure 6 prove that
study, the CS of the composites decreased as the the interfacial adhesion between the resin and the
sample thickness increased, as expected. This was particles was strong in each of the tested samples.
possibly due to the reduction in the DC values, as ACTIVA probably includes particles with a broader
previously reported (4,37). At a thickness of 2mm, size distribution. One can easily note that the
it was found that the CS decreased in the order rough fracturing tracks shift to smoother, vertica-
of Filtek Z250>Fill-Up>HyperFIL>ACTIVA. The CS lly aligned tracks with an increase in thickness.
values of Fill-Up, ACTIVA, and HyperFIL were found This was probably due to the decrease in the DC%
to be similar at a thickness of 6 mm, whereas Filtek with increasing thickness and the occurrence of
Z250 yielded the highest CS at this thickness. This fracturing throughout the resin phase (4). It may
result clearly implies that the CS was not greatly be concluded that the resin phase, which has
influenced by the DC when the cured composite much lower stiffness than the inorganic particles,
was relatively thick. In these circumstances, it can is mainly responsible for the fracturing of thick
be concluded that the most effectual parameter is composites, based on the similarities observed
the number of inorganic particles because Filtek between Figure 7.c and Figure 7.d.
Z250 possesses a higher inorganic content than
the other composites. The CS values recorded in Dual-cure bulk-fill RBCs are new to the
this study are also consistent with those repor- market, and further studies are needed to deter-
ted in a previous study. Khosrevani reported the mine their long-term clinical performance. Additio-
CS and elastic modulus values of Filtek Z250 as nal research is needed to validate the results of
418±16 MPa and 2.14±0.15 GPa, respectively, our study, especially studies with different dual-
when tested at a thickness of 4mm (44). cure bulk-fill composite materials.
7. Reis A.F., Vestphal M., Amaral R.C.D., 16. Opdam N.J., Bronkhorst E.M., Roeters J.M.,
Rodrigues J.A., Roulet J.F., Roscoe M.G. Loomans B.A. A retrospective clinical study
Efficiency of polymerization of bulk-fill on longevity of posterior composite and
composite resins: a systematic review. Braz amalgam restorations. Dent Mater. 2007; 23
Oral Res. 2017; 31 (suppl 1): e59. (1): 2-8.
8. Benetti A.R., Havndrup-Pedersen C., Honore 17. Cebe M.A., Cebe F., Cengiz M.F., Cetin A.R.,
D., Pedersen M.K., Pallesen U. Bulk-fill Arpag O.F., Ozturk B. Elution of monomer
resin composites: polymerization contrac- from different bulk fill dental composite
tion, depth of cure, and gap formation. Oper resins. Dent Mater. 2015; 31 (7): e141-9.
Dent. 2015; 40 (2): 190-200. 18. Tanaka K., Taira M., Shintani H., Wakasa K.,
9. Toh W.S., Yap A.U., Lim S.Y. In Vitro Yamaki M. Residual monomers (TEGDMA
Biocompatibility of Contemporary Bulk- and Bis-GMA) of a set visible-light-cured
fill Composites. Oper Dent. 2015; 40 (6): dental composite resin when immersed in
644-52. water. J Oral Rehabil. 1991; 18 (4): 353-62.
10. de Mendonca B.C., Soto-Montero J.R., de 19. Vankerckhoven H., Lambrechts P., van
Castro E.F., Kury M., Cavalli V., Rueggeberg Beylen M., Davidson C.L., Vanherle G.
F.A., et al. Effect of extended light activation Unreacted methacrylate groups on the surfa-
and increment thickness on physical proper- ces of composite resins. J Dent Res. 1982; 61
ties of conventional and bulk-filled resin- (6): 791-5.
based composites. Clin Oral Investig. 2022; 20. Hayashi J., Espigares J., Takagaki T.,
26 (3): 3141-50. Shimada Y., Tagami J., Numata T., Chan D.,
11. Ferracane J.L., Mitchem J.C., Condon J.R., Sadr A. Real-time in-depth imaging of gap
Todd R. Wear and marginal breakdown of formation in bulk-fill resin composites. Dent
composites with various degrees of cure. J Mater. 2019; 35: 585-96.
Dent Res. 1997; 76 (8): 1508-16. 21. Vandewalker J.P., Casey J.A., Lincoln
12. Stansbury J.W. Curing dental resins and T.A., Vandewalle K.S. Properties of dual-
composites by photopolymerization. J Esthet cure, bulk-fill composite resin restorative
Dent. 2000; 12 (6): 300-8. materials. Gen Dent. 2016; 64 (2): 68-73.
13. Kwaśny M,. Bombalska A., Obroniecka K. 22. de Mendonça B.C., Soto-Montero J.R., de
A reliable method of measuring the conver- Castro E.F., Pecorari V.G.A., Rueggeberg F.A.,
sion degrees of methacrylate dental resins. Giannini M. Flexural strength and microhard-
Sensors (Basel). 2022; 10; 22 (6): 2170. ness of bulk-fill restorative materials. J Esthet
14. da Silva E.M., Almeida G.S., Poskus L.T., Restor Dent. 2021; 33 (4): 628-35.
Guimaraes J.G. Relationship between the 23. Bouschlicher M.R., Rueggeberg F.A., Wilson
degree of conversion, solubility and salivary B.M. Correlation of bottom-to-top surface
sorption of a hybrid and a nanofilled resin microhardness and conversion ratios for a
composite. J Appl Oral Sci. 2008; 16 (2): variety of resin composite compositions.
161-6. Oper Dent. 2004; 29 (6): 698-704.
15. Schneider L.F., Pfeifer C.S., Consani S., Prahl 24. Alrahlah A. Diametral tensile strength, flexu-
S.A., Ferracane J.L. Influence of photoinitia- ral strength, and surface microhardness of
tor type on the rate of polymerization, degree bioactive bulk fill restorative. J Contemp
of conversion, hardness and yellowing of Dent Pract. 2018; 19 (1): 13-9.
dental resin composites. Dent Mater. 2008; 25. Daabash R., Alshabib A., Alqahtani M.Q,.
24 (9): 1169-77. Price R.B., Silikas N., Alshaafi M.M. Ion
releasing direct restorative materials: Key mechanical properties of two bulk-fill flowa-
mechanical properties and wear. Dent Mater. ble RBC base materials. Dent Mater. 2013;
2022 Oct 3:S0109-5641 (22) 00274-3. 29 (8): 906-12.
26. Hughes K.O., Powell K.J., Hill A.E., Tantbi- 34. Sideridou I., Tserki V., Papanastasiou G.
rojn D., Versluis A. Delayed Photoactivation Effect of chemical structure on degree of
of Dual-cure Composites: Effect on Cuspal conversion in light-cured dimethacrylate-
Flexure, Depth-of-cure, and Mechanical based dental resins. Biomaterials. 2002; 23
Properties. Oper Dent. 2019; 44 (2): 97-104. (8): 1819-29.
27. Borges A., Chase M., Niederberger A., 35. Yoon T.H., Lee Y.K., Lim B.S., Kim C.W.
Gonzalez M., Ribeiro A., Pascon F., et al. A Degree of polymerization of resin composi-
Critical Review on the Conversion Degree of tes by different light sources. J Oral Rehabil.
Resin Monomers by Direct Analyses. Brazi- 2002; 29 (12): 1165-73.
lian Dental Science. 2013;16. 36. Halvorson R.H., Erickson R.L., Davidson
28. Yokesh C.A., Hemalatha P., Muthalagu M., C.L. The effect of filler and silane content on
Justin M.R. Comparative Evaluation of the conversion of resin-based composite. Dent
Depth of Cure and Degree of Conversion of Mater. 2003; 19 (4): 327-33.
Two Bulk Fill Flowable Composites. J Clin 37. Kaya M.S., Bakkal M., Durmus A., Durmus
Diagn Res. 2017; 11 (8): ZC86-ZC9. Z. Structural and mechanical properties of a
29. Nascimento A.S., Lima D.B., Fook M.V.L., giomer-based bulk fill restorative in different
Albuquerque M.S., Lima E.A., Sabino M.A., curing conditions. J Appl Oral Sci. 2018; 26:
et al. Physicomechanical characterization e20160662.
and biological evaluation of bulk-fill compo- 38. Ilie N. Microstructural dependence of
site resin. Braz Oral Res. 2018; 32: e107. mechanical properties and their relationship
30. Lovell L.G., Newman S.M., Bowman C.N. in modern resin-based composite materials. J
The effects of light intensity, temperature, Dent. 2021;114:103829.
and comonomer composition on the polyme- 39. Heintze S.D., Ilie N., Hickel R., Reis A.,
rization behavior of dimethacrylate dental Loguercio A., Rousson V. Laboratory mecha-
resins. J Dent Res. 1999; 78 (8): 1469-76. nical parameters of composite resins and
31. Fraga M.A.A., Correr-Sobrinho L., Sinho- their relation to fractures and wear in clinical
reti M.A.C., Carletti T.M., Correr A.B. Do trials-A systematic review. Dent Mater. 2017;
dual-cure bulk-fill resin composites reduce 33 (3): e101-e14.
gaps and improve depth of cure. Braz Dent J. 40. Poiate I.A., Vasconcellos A.B., Poiate Junior
2021; 32 (5): 77-86. E., Dias K.R. Stress distribution in the cervi-
32. Lindberg A., Peutzfeldt A., van Dijken J.W. cal region of an upper central incisor in a 3D
Curing depths of a universal hybrid and a finite element model. Braz Oral Res. 2009;
flowable resin composite cured with quartz 23 (2): 161-8.
tungsten halogen and light-emitting diode 41. Sana S., Kondody R.T., Talapaneni A.K.,
units. Acta Odontol Scand. 2004; 62 (2): Fatima A., Bangi S.L. Occlusal stress distri-
97-101. bution in the human skull with permanent
33. Finan L., Palin W.M., Moskwa N., McGinley maxillary first molar extraction: A 3-dimen-
E.L., Fleming G.J. The influence of irradia- sional finite element study. Am J Orthod
tion potential on the degree of conversion and Dentofacial Orthop. 2021; 160 (4): 552-9.
42. Campaner L.M., Ribeiro A.O., Tribst J.P.M., loading conditions. J Mech Behav Biomed
Borges A.L., Di Lauro A.E., Lanzotti A., et al. Mater. 2019;93:151-7.
Loading stress distribution in posterior teeth 45. Scribante A., Bollardi M., Chiesa M.,
restored by different core materials under Poggio C., Colombo M. Flexural Proper-
fixed zirconia partial denture: A 3D-FEA ties and Elastic Modulus of Different Esthe-
study. Am J Dent. 2021; 34 (3): 157-62. tic Restorative Materials: Evaluation after
43. Bicalho A.A., Tantbirojn D., Versluis A., Exposure to Acidic Drink. Biomed Res Int.
Soares C.J. Effect of occlusal loading and 2019; 2019: 5109481.
mechanical properties of resin composite on 46. Leprince J.G., Palin W.M., Vanacker J.,
stress generated in posterior restorations. Am Sabbagh J., Devaux J., Leloup G. Physico-
J Dent. 2014; 27 (3): 129-33. mechanical characteristics of commercially
44. Khosravani M.R. Mechanical behavior of available bulk-fill composites. J Dent. 2014;
restorative dental composites under various 42 (8): 993-1000.