You are on page 1of 1

Catalog PCC-4/USA (Revised 09-18-14) Logic

Part Numbers Time Delay Relays

Time Delay Relays Specifications


For Mounting on any 2* or 3-Port Subbase Air Quality -
Using Atmospheric Air for Control Standard Shop Air, Lubricated or Dry, 40 μm Filtration

Single Turn Adjustment Cv .............................................................................0.14 (1.8)


Filter .............................................. a-PPRL23, Vent - PPRL20
A
Output
(S or 3
- Red) Flow rate at 90 PSI (6 bar) in SCFM (l/mn ANR) ....6.4 (180)
Supply t1 0 ON Delay Interchangable 50 μm Filter –
(P or 2
- Black/None) Signal a (Input)...................................................................PPRL23
(a or 1 Input Cylinder ..........................................................PPRL20
- Green)
Output
Materials –
(S or 3 - Body...................................................................Polyamide
- Red) - Poppet........................................................... Polyurethane
t1 0 - Seals ......................................................... Nitrile (Buna N)
Supply OFF Delay
(P or 2
- Black/None) Signal Mounting ................................................ 2 or 3-Port Subbase
(a or 1
- Green) PRTA10 Number of Operations with Dry Air at 90 PSI and 70°F,
*Function Must Be Checked. Frequency 1 Hz .......................................................10 Million
Operating Positions........................................................... All
Part Number Description Timing Range
Operating Pressure ....................40 to 115 PSIG (3 to 8 bar)
PRTE10 ON Delay 0.1 to 3 sec.
Repeatability ........................................... ±5% / 5 Operations
PRTA10 ON Delay 0.1 to 30 sec.
Response Time ................................................... 2 to 3 msec
PRTB10 ON Delay 10 to 180 sec. Temperature –
PRTF10 OFF Delay 0.1 to 3 sec. Operating .............................. 32°F to 122°F (0°C to +50°C)
Storage .............................-22°F to 140°F (-30°C to +60°C)
PRTC10 OFF Delay 0.1 to 30 sec.
PRTD10 OFF Delay 10 to 180 sec.
Tamperproof Cap
PRTA12 PRTA10 on PZUA12 Subbase
• Locking
LA9D901 Tamperproof Cap Set desired time delay, then place transparent cap over
setting knob and tighten screw.
The Time Delay Relay delays a maintained input signal • Sealing
during an adjustable time period after which a regenerated Bend tab over screw head; run wire over head, then seal.
output appears.
Screw Tab Seal
Setting
• Delay is set by turning knob.
• One 360° turn covers complete timing range. Transparent
• When white line on dial is set at top dead center, TDR Cap
goes to infinity. This feature facilitates machine set up.
Connections: 3-Port Subbase with
• Instant Straight Connections
• Instant Swivel Connections
Dimensions
PRT•10
• 1/8" NPT Female Connections
Timing Functions
• Positive Output 1.31
(33) Dia.
Pressure
Control Signal a

Time Delay Relay: .56


Positive Output
(14)
0
Output Signal S 1.91
Adjustable Time Time (48)

• Inverted Output
Pressure 0
Control Signal a
A

Time Delay Relay: 1.66


F

1.41
Inverted Output, M4 (42)
(36)
B

Adjustable Pulse D
C
Output Signal S Function
0
T Time
3.84
Repeatability +2% (98)

A15 Parker Hannifin Corporation


Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics