Professional Documents
Culture Documents
The EUROPEAN Lead Fast Reactor Demonstrator PDF
The EUROPEAN Lead Fast Reactor Demonstrator PDF
The EUROPEAN
Lead Fast Reactor Demonstrator
Alessandro
Alemberti
ALFRED
EVOLUTION, GOALS and the SIX Generation IV
International Forum (GIF) Reactor Concepts
GEN IV - GOALS
SUSTAINABILITY:
effective fuel utilization;
reduce the long-term waste
ECONOMICS:
cost advantage
Limited financial risk
Strategy:
LFR road-map
Exp. Facilities ETPP DEMO PROTOTYPE First of a Kind
GUINEVERE MYRRHA ALFRED PROLFR ELFR
ELECTRA
EU-Lab Exp.
ALFRED – DESIGN GUIDELINES
4 Safety Rods
12 Control Rods
Hole for
Instruments
ALFRED - Inner Vessel
Upper grid
Main Vessel
Cylinder
Pin
Inner Vessel
Lower grid assembly
Inner Vessel
ALFRED - Steam Generator Bayonet Tube Concept
SGs Tubes, forged plates and shells made of Steam Generator Performance
X10CrMoVNb9-1, RCC-MRx code (T91 steel) Removed Power [MW]
37.5
Core outlet Lead Temperature [°C]
480.0
Pump casing
Core inlet Lead Temperature [°C]
400.0
Feedwater Temperature [°C]
335.0
Steam outlet
Tubes
Second
tubesheet
First tubesheet
ALFRED - Reactor Block Configuration
Decay Heat Removal Systems
• Several systems for the decay heat removal function have been conceived and
designed for ALFRED
– One non safety-grade system, the secondary system, used for the normal decay
heat removal following the reactor shutdown
– Two independent, passive, high reliable and redundant safety-related Decay
Heat
Removal systems (DHR N1 and DHR N2): in case of unavailability of the
secondary
system, the DHR N1 system is called upon and in the unlike event of
unavailability of
the first two systems the DHR N2 starts to evacuate the DHR
• DHR N1:
– Isolation Condenser system connected to four out of eight SGs
• DHR N2:
– Other four Isolation Condenser to the other four SGs have been added
Consider that, each SG is continuously monitored, ALFRED is a
demonstrator
and a redundancy of 266% is maintained
• DHR Systems features:
Independence obtained by means of two different systems with nothing in
common
Redundancy is obtained by means of three out of four loops (of each system)
sufficient to fulfil the DHR safety function even if a single failure occurs
Isolation Condenser History
• 8 Independent loops
• DHR N1 4 loops
• DHR N2 the other 4 loops
• Each Isolation Condenser loop is
comprehensive of:
– One heat exchanger (Isolation
Condenser), constituted by a vertical tube
bundle with an upper and lower header
– One water pool, where the isolation
condenser is immersed (the amount of
water contained in the pool is sufficient to
guarantee 3 days of operation)
1 loop (typical)
– One condensate isolation valve (function
will be performed by at least two parallel
valves)
ALFRED - Isolation Condenser Heat Exchanger
500
550
480
460
500
440
420
450
400
°C
°C
360
340
350
320
Freezing temperature
300
300
Freezing temperature
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000
• GUINEVERE is operating
critical condition achieved in February 2011
sub-critical coupling with accelerator achieved in November 2011