Professional Documents
Culture Documents
E 10 04
T W M
ISSUE ST EDITION
D LE EA
MID
TEKNOWARE 4
CENTRAL MONITORING 37
CONTENTS 116
TEKNOWARE OY
Teknoware Oy is an international Both electronic and mechanical components
electronics company located in Lahti, are engineered and manufactured
in our factory in Lahti, Finland. Also
Finland. We design and manufacture our sales unit is located in Lahti.
LED-based vehicle interior lighting In addition to partners operating in more
than 20 countries around the world,
systems, and emergency lighting systems we have sales units in the United Arab
for buildings and ships. We employ Emirates, the USA, Sweden and Brazil.
approximately 360 people. We have Made in Finland
production facilities in Lahti and in
Connecticut, in the United States. We Lahti
Teknoware worldwide
Teknoware started a big factory Teknoware opened subsidiary in Sweden North Gate Mall in Doha, Qatar will be
expansion at Ilmarisentie 3, Lahti, in January 2015. The aim is to obtain a one of the world´s biggest Shopping
Finland. New expansion will increase stronger position, and to introduce new, Centres. Teknoware’s Central Battery
the production and office space by technologically advanced emergency Systems and luminaires are used in the
4,500 m². The new building is expected lighting solutions on the Swedish market. project.
to be in use by summer 2016.
In addition to traditional emergency Teknoware has
lighting products, Teknoware will focus been part of
on its self-contained ESCAP emergency Helsinki Airport
lights, where the battery is replaced already since 1980,
with an environmentally friendly Super along with every
capacitor, as well as AALTO CONTROL, expansion and reconstruction of the
the advanced, wireless remote airport. Currently, there is an on-going
monitoring system. expansion of P5 Parking Garage, with
The investment will ensure a sufficient
3,000 new parking spaces. P5 Parking
production capacity also in the future,
Garage will be opened in summer
and help to meet the growing customer
2016, equipped with Teknoware’s latest
demand
emergency lighting system.
4
Teknoware Emergency Lighting Product Catalogue
TOUR OF THE TEKNOWARE FACTORIES IN LAHTI
5
Teknoware Emergency Lighting Product Catalogue
EMERGENCY LIGHTING SYSTEMS
Teknoware offers a complete range of The Most Innovative Product at the practice, this means that the device must
Emergency Lighting products, based on Sähkö Tele Valo & AV fair in Finland. be designed especially for Emergency
the following three main categories: Afterwards, it has continued to grow Lighting usage. UPS devices and central
its popularity, both in Finland and units used for controlling other systems,
• Central Battery Systems
internationally. With the development originally not designed for Emergency
of Super capacitors and LEDs, the Lighting use don’t typically meet the
• Self-Contained Emergency and Exit
performance and cost effectiveness requirements of EN 50171.
Lights, using a traditional battery
has increased further. Currently, there is
already the 3rd generation of the ESCAP Teknoware offers a wide range of Central
• ESCAP Self-Contained Emergency and Battery Systems, specifically designed
technology in production.
Exit Lights, using a maintenance-free and manufactured for Emergency
and environmentally friendly Super Lighting usage. Thanks to the modular
capacitor technology product range, we can offer solutions
REMOTE MONITORING SYSTEMS for buildings of all sizes. Starting from
our basic models, all the types fulfil the
Teknoware offers a comprehensive
In Central Battery Systems, the batteries requirements of the standard EN 50171.
range of alternatives for the
and the most important actuators In addition we offer several options
effective Centralized Monitoring of
are centrally located, which is a big making the controlling, monitoring and
the Emergency Lighting Systems.
advantage concerning maintenance servicing easier.
Teknoware’s Central Monitoring Systems
and service. The larger the building, the
provide real time information on the
bigger the advantage.
automatic tests, as well as a log book.
In Self-Contained Systems, each There are even options to access the
Emergency and Exit Light has its own system through the Internet.
backup power source, traditionally a
battery. This kind of a system is the most
applicable in such buildings, where the
maintenance of the batteries, located
in each luminaire, can be arranged with
reasonable costs.
6
Teknoware Emergency Lighting Product Catalogue
AN EMERGENCY LUMINAIRE IS A
SAFETY EQUIPMENT
The primary function of the Emergency SGS Fimko, as a sign of which they have based on them. The luminous flux values
Lighting is to ensure a fast and safe SGS Fimko marking on them. are measured with the Ulbricht’s sphere,
evacuation of the building, in the case in our own lighting laboratory.
of an emergency. This is valid both,
when the general lighting is working, as
LEDS ARE TODAY´S TECHNOLOGY
well as when there is a power outage.
The escape route is marked with Exit The LEDs have been developing notably
Lights. The safe moving in the escape fast, regarding the light efficacy, as well
THE PERFORMANCE REQUIREMENTS
route, and in the open areas, is secured as the dependability. Nowadays, the
FOR THE EXIT LIGHTS
with Emergency Lights, giving general LEDs are a considerable option for very
light. The observability of the Exit Lights Teknoware Exit Lights fulfil the many lighting applications. In Emergency
becomes even more important, when performance requirements of the Lighting solutions, LEDs have been used
the general lighting is still functional, European standard EN 1838. This for several years already.
because the pictograms in Exit Lights standard determines the requirements
must always clearly stand out from both for the luminance and the contrasts. Teknoware has been one of the pioneers
the surroundings. Also, the possible The minimum luminance of the green in this field, and continues to be it, still
smoke poses a big challenge to the area is 2 cd/m2. The contrast between today. Our first Exit Light with green
observability of the Exit Lighting. the white and the green area must be LEDs, LEDMAN, was introduced in the
between 1:5 and 1:15. Within the same mid 90’s, and more than 15 years ago
In Emergency Lighting, the performance we introduced our first Exit Lights with
colour, the contrast must be less than
of the light is a crucial safety factor, white LEDs. Even today, our luminaires
1:10. These will guarantee the minimum
which means that it must always fulfil are continuously developed further,
observability for the pictogram. This is
its requirements. This is ensured, by by applying the most advanced LED
the most important feature of an Exit
following the relevant standards, technology and optics.
Light, and it cannot be neglected e.g.
the most important of which are the
due to the quest for a lower energy
European standards for Emergency
consumption, or the product costs. In
Lighting, EN 1838 and EN 60598-2-
the end, the owner of the building is
22 for the luminaires, and EN 50171
responsible for the emergency lighting
for Central Battery Systems. In Europe,
system to be according to the standards. LEDMAN from 1995
the responsibility for the conformity
of an electric device belongs to the Today, the LEDs play an important role,
manufacturer. As a sign of this, the also as the light source of Emergency
manufacturer attaches a CE marking THE PHOTOMETRIC PROPERTIES OF Lights, giving overall illumination.
in the device. A common problem is, THE EMERGENCY LIGHTS Compared to fluorescent tubes, they
however, that the CE marking as such make it possible to design remarkably
The purpose of Emergency Lights is
alone does not guarantee the safety of smaller luminaires, with a considerable
to give a minimum illuminance level
the device. The CE marking is only the decrease in energy consumption.
for orientation, during a power failure.
manufacturer’s own promise, for which
According to the European standard Compared to other luminaire sources,
the arguments may sometimes be rather
EN 1838, the minimum is 1,0 lux for the LEDs mean, however, also new
inadequate. A conscious manufacturer,
escape routes and 0,5 lux for open technical challenges for the design
such as Teknoware, takes care of fulfilling
areas. In order for this to be achieved, of the luminaires. The correct thermal
the requirements already in the design
the photometric data of each luminaire design is crucial, when it comes to the
phase of the products. The only reliable
is required, in the system planning stage. lifetime of the LED, and the photometric
way to do this, are the measurements
The Emergency Lighting Standard benefits can only be utilized with efficient
and tests, according to the standards,
EN 60598 - 2 - 22 requires, that the optics. Due to this, it is important, that
with appropriate and calibrated
manufacturer of an Emergency Light the luminaire design is initially made for
measuring devices. This goes for
must give the verified data for each LEDs, rather than an upgrade of an old
electromagnetic compatibility, electric
luminaire. We provide the luminous flux design for fluorescent lights.
safety and also for the performance
values and light distribution tables for all
of the product. We can present At Teknoware, we combine our long-
our Emergency Lights. For the simulation
these documents for our products, if time experience with the utilization of
with the DIALux software, we also
requested. the latest design tools and measuring
provide the necessary Eulumdat files.
devices, in our day-to-day design
In addition to the CE marking, our main
The data of the luminaires is based on process.
products are also 3rd-party-certified, by
real measurements, and the simulations
7
Teknoware Emergency Lighting Product Catalogue
REFERENCES
8
Teknoware Emergency Lighting Product Catalogue
CENTRAL BATTERY SYSTEMS
SYSTEMS
230 V CENTRAL BATTERY SYSTEMS | TKT65B 22
Battery SystemS
24 V CENTRAL BATTERY SYSTEMS | TKT31, TKT41 24
Central BATTERY
ACCESSORIES FOR CENTRAL BATTERY SYSTEMS 26
CENTRAL
LOCAL CONTROLLER | TS906, TST68 32
SEPARATE ADDRESS MODULES | TS982, TST96 34
CENTRAL MONITORING OPTIONS | WEBCM & WEBACM, ACM, BACNET, LON, BCM 37
9
Teknoware Emergency Lighting Product Catalogue
FEATURES OF CENTRAL BATTERY SYSTEMS
Basic information
Features
Circuit Monitoring — — —
Integrated printer — — —
LCD Display — — —
LON Interface — — —
BACnet Interface — — —
Compatibility of external
system modules
Local Controller — — x
Switch Controller — — x
Address module — — x
10
Teknoware Emergency Lighting Product Catalogue
TKT65xxC TKT65xxCP TKT66xxC(F/P) TKT67xxC TKT68xxC
230 VAC 230 VAC 220-240 VAC 220-240 VAC 220-240 VAC
216 VDC 216 VDC 216 VDC 216 VDC 216 VDC
216 VDC 216 VDC 216 VDC 216 VDC 216 VDC
65 Ah 65 Ah 65 Ah 450 Ah 65 Ah
2000 W-6000 W 2000 W-6000 W 2800 W-6000 W 5600 W-19600 W 2800 W-6000 W
— — x x x
x x x x x
x x x x x
x x x x x
x x x x x
x x x x x
x x x x x
11
Teknoware Emergency Lighting Product Catalogue
ADDRESSABLE TAPSA CONTROL
CENTRAL BATTERY SYSTEMS
The addressable testing of Tapsa Control data cabling between the luminaires.
• In addition to the scheduled tests, the
Central Battery Systems, together with The luminaires must be addressable,
condition of the batteries is monitored
a wide selection of Central Monitoring of the Teknoware products with the
continuously.
options, offers considerable savings in letter K in the end, or they must have
Emergency Lighting system maintenance a separate address module. Utilisation
• They are fully compatible with
and service. of these luminaires also enables the
Teknoware’s Local Contoller and
connection of maintained and non-
The addressable Central Battery Systems Switch Controller, as well as Intelligent
maintained Emergency and Exit Lights
offer effective solutions, for supplying Controller.
to the same luminaire circuit, and allows
a large quantity of luminaires. They are the monitoring of the local supply, using
suited for small and large premises, • User can program battery operation to
Teknoware Local Controller, or Intelligent
depending on the type of the Central continue from 1 to 15 minutes, after the
Controller system.
Battery System. A maximum of 12- electric power has been restored
32 addressable luminaires can be The addressable Tapsa Control Central
connected to one luminaire circuit, Battery Systems include all the basic
depending on the type of the Central functions, required by the standard
Battery System. EN50171. Moreover, the following
additional features, among others, are
In addition to the normal Emergency included:
Lighting functions, the addressable
Central Battery Systems in the Tapsa • The system is self-learning, which
Control series make it possible to test enables automatic configuration during
automatically the condition of the the commissioning.
central unit itself, and the luminaires
connected to it. The testing of the • The system performs an automatic
luminaires is based on individual luminaire test once every day, or week,
addresses, and the communication is and a battery duration test once every
by means of the power supply cables. six months.
Thus, there is no need for any separate
mains supply 1 2 3 4 32
Tapsa 1
Control
2
CBU
3 up to 32 luminaires
in the same circuit
free circuit
Battery arrangement
Cabinet
= non-maintained luminaire
12
Teknoware Emergency Lighting Product Catalogue
COMPONENTS OF THE ADDRESSABLE TAPSA CONTROL CENTRAL BATTERY SYSTEMS
13
Teknoware Emergency Lighting Product Catalogue
TAPSA CONTROL TKT67xxC EN
50171
IP
31
Central Battery Systems in the TKT67 series make it possible to test using Teknoware Local Controller, or
series offer effective solutions for automatically the condition of the Intelligent Controller, which can also
supplying a large quantity of luminaires. central unit itself and the luminaires be used to control the non-maintained
They are especially suited for large connected to it. The testing of luminaires emergency lights.
premises. is based on individual addresses and These Central Battery Systems have,
The central unit input voltage is the communication is by means of the depending on the model, either 16, 24,
220-240 VAC. The output voltage is power supply cables. Thus there is no 32, 40, 48 or 56 output circuits, which
220-240 VAC in normal mode and need for any separate data cabling can be set to function as maintained
216 VDC in battery mode. The battery between the luminaires. The luminaires or non-maintained. A maximum of
voltage is 216 V, which is achieved by must be addressable, of the Teknoware 32 addressable luminaires can be
connecting eighteen 12 volt batteries in model ending in K, or they must have connected to one circuit. Circuits can
series. a separate address module. Utilisation also be connected in parallel to increase
of the luminaires also enables the the output power with the following
In addition to the normal emergency connection of maintained and non-
lighting functions, Central Battery changeover module outputs possible:
maintained lights to the same circuit 8 x 350 VA, 4 x 700 VA or 2 x 1400 VA.
Systems in the Tapsa Control TKT67C and allows local supply monitoring
DIMENSIONS
509 601
601
509
1929 1929
597
R597
14
Teknoware Emergency Lighting Product Catalogue
TYPE OF THE CBS
Product code Max input Number of circuits / Max load, Max total load Weight
power (mains) Outputs maintained lights 1-3 h durations (kg)
OPTIONAL FEATURES
Product code Product description For
15
Teknoware Emergency Lighting Product Catalogue
TAPSA CONTROL TKT68xxCx EN
50171
IP
31
A MAXIMUM
230 V NO SEPARATE
OF 32
ADDRESSABLE BATTERY
ADDRESSABLE
CENTRAL CABINET
LUMINAIRES /
BATTERY NEEDED
ONE CIRCUIT
SYSTEM
Central Battery Systems in the TKT68C TKT68C Central Battery System can Utilisation of these luminaires also
series offer effective and space-saving fit batteries of up to 18 x 65 Ah into its enables the connection of maintained
solutions for supplying a moderate casing; therefore, it is well suited for and non-maintained lights to the
quantity of luminaires. They are locations where only a limited amount of same circuit and allows local supply
especially suited for mid-sized and large space is available. monitoring using Teknoware Local
premises where it is desirable to divide Controller, or Intelligent Controller,
the central battery system into multiple In addition to the normal emergency which can also be used to control the
independent regions. lighting functions, Central Battery non-maintained emergency lights.
Systems in the Tapsa Control TKT68C
The central unit input voltage is series make it possible to test These central batteryunits have,
220-240 VAC, except for three phase automatically the condition of the central depending on the model, either 8,
input models (that end in letter F) the unit itself and the luminaires connected 16 or 24 output circuits, which can
input voltage, of which is 400 VAC to it. The testing of luminaires is based on be set to function as maintained
between the phases. The output voltage individual addresses. The communication of non-maintained. A maximum of
is 220-240 VAC in normal mode and is by means of the power supply cables. 32 addressable luminaires can be
216 VDC in battery mode. The battery Thus there is no need for any separate connected to one circuit. Circuits can
voltage is 216 V, which is achieved by data cabling between the luminaires. The also be connected in parallel to increase
connecting eighteen 12 volt batteries in luminaires must be addressable, of the the output power with the following
series. Teknoware model ending in K, or they changeover module outputs possible:
must have a separate address module. 8 x 350 VA, 4 x 700 VA or 2 x 1400 VA.
DIMENSIONS
506 859
859
506
1921 1921
R645
R194
R852
16
Teknoware Emergency Lighting Product Catalogue
TYPE OF THE CBS
Product code Max input Number of circuits/ Max load, Max total load, Max total load, Weight
power (mains) Outputs maintained 1 h duration 3 h duration (kg)
lights
OPTIONAL FEATURES
Product code Product description For
17
Teknoware Emergency Lighting Product Catalogue
TAPSA CONTROL TKT66xxCx EN
50171
IP
20
IP
34
TKT66XXC TKT66XXCP
Central Battery Systems in the TKT66C In addition to the normal emergency same circuit and allows local supply
series offer effective and space-saving lighting functions, Central Battery monitoring using Teknoware Local
solutions for supplying a moderate Systems in the Tapsa Control TKT66C Controller, or Intelligent Controller,
quantity of luminaires. They are series make it possible to test which can also be used to control the
especially suited for mid-sized and large automatically the condition of the non-maintained emergency lights.
premises where it is desirable to divide central unit itself and the luminaires
the central battery system into multiple connected to it. The testing of luminaires These central units have, depending
independent regions. is based on individual addresses and on the model, either 8, 16 or 24 output
the communication is by means of the circuits, which can be set to function
The central unit input voltage is power supply cables. Thus, there is no as maintained of non-maintained. A
220-240 VAC, except for three phase need for any separate data cabling maximum of 32 addressable luminaires
input models (that end in letter F) the between the luminaires. The luminaires can be connected to one circuit. Circuits
input voltage, of which is 400 VAC must be addressable, of the Teknoware can also be connected in parallel to
between the phases. The output voltage model ending in K, or they must have a increase the output power with the
is 220-240 VAC in normal mode and separate address module. following changeover module outputs
216 VDC in battery mode. The battery possible: 8 x 350 VA, 4 x 700 VA or 2 x
voltage is 216 V, which is achieved by Utilisation of these luminaires also 1400 VA.
connecting eighteen 12 volt batteries in enables the connection of maintained
series. and non-maintained lights to the
DIMENSIONS
TKT66XXC TKT66XXCP
600 240 572 690
23
654 262
654 6
72
690
215 240
262
600
R690
18
Teknoware Emergency Lighting Product Catalogue
TYPE OF THE CBS
Product code Max input Number of circuits / Max load, Max total load, Max total load, Weight
power (mains) Outputs maintained lights 1 h duration 3 h duration (kg)
OPTIONAL FEATURES
Product code Product description For
19
Teknoware Emergency Lighting Product Catalogue
TAPSA CONTROL TKT65xxCx EN
50171
IP
20
IP
34
TKT65XXC TKT65XXCP
Central Battery Systems in the TKT65C Systems in the Tapsa Control TKT65C maintained lights to the same circuit
series offer effective solutions for series make it possible to test and allows local supply monitoring
supplying a moderate number of lights. automatically the condition of the using Teknoware Local Controller, or
They are especially suited for mid-sized central unit itself and the luminaires Intelligent Controller, which can also
and large premises where it is desirable connected to it. The testing of luminaires be used to control the non-maintained
to divide the central system into multiple is based on individual addresses and emergency lights.
independent regions. the communication is by means of the These central units have, depending
The central unit input voltage is power supply cables. Thus there is no on the model, either 8, 16 or 24 output
230 VAC. The output voltage is need for any separate data cabling circuits, which can be set to function
230 VAC in normal mode and 216 VDC between the luminaires. The luminaires as maintained or non-maintained. A
in battery mode. The battery voltage is must be addressable, of the Teknoware maximum of 16 addressable luminaires
216 V, which is achieved by connecting model ending in K, or they must have can be connected to one circuit.
eighteen 12 volt batteries in series. a separate address module. Utilisation
of these luminaires also enables the
In addition to the normal emergency connection of maintained and non-
lighting functions, Central Battery
DIMENSIONS
TKT65XXC TKT65XXCP
518 239 490 630
6 6
590 262 590
40
67
518
630
239 262
R630
20
Teknoware Emergency Lighting Product Catalogue
TYPE OF THE CBS
Product code Max input Number of circuits/ Outputs Max load, Max total load, Weight (kg)
power (mains) maintained lights 1 h duration
OPTIONAL FEATURES
Product code Product description For
21
Teknoware Emergency Lighting Product Catalogue
TKT65xxBx EN
50171
IP
20
IP
34
ALWAYS NEEDS
230 V 18 BATTERIES,
CENTRAL A BATTERY
BATTERY CABINET +
SYSTEM BATTERY CABLES
Central Battery Systems in the TKT65B The Central Battery System input voltage These Central Battery Systems have,
series offer simple solutions for supplying is 230 VAC, except for three phase input depending on the model, either 6, 12,
a moderate number of lights. They are models (that end in letter F) the input 18 or 24 output circuits, which can be
especially suited for mid-sized and large voltage, of which is 400 VAC between set to function as maintained or non-
premises where it is desirable to divide the phases. The output voltage is maintained in groups of two.
the central battery system into multiple 230 VAC in normal mode and 216 VDC
independent regions. in battery mode. The battery voltage is
216 V, which is achieved by connecting
eighteen 12 volt batteries in series.
DIMENSIONS
TKT65XXB TKT65XXBP
518 242 490 6 630
262 590 6
590
41
67
518 630
262
242
R630
22
Teknoware Emergency Lighting Product Catalogue
TYPE OF THE CBS
Product code Max input Number of circuits/ Max load, Max total load, Weight
power (mains) Outputs maintained lights 1 h duration (kg)
OPTIONAL FEATURES
Product code Product description For
23
Teknoware Emergency Lighting Product Catalogue
TKT31/41xx EN
50171
IP
20
Central Battery Systems in the TKT3122 The Central Battery System input voltage depending on the model, either 8 or 16
and TKT41 series offer simple solutions is 230 VAC. The output voltage is output circuits.
for supplying a relatively small number 24 VAC in normal mode and 24 VDC TKT3122 Central Battery System has
of lights in a limited area. They are in battery mode. The battery voltage is 4 output circuits, which can be set
especially suited for small premises 24 V, which is achieved by connecting to function as maintained or non-
and applications where it is desirable to two 12 volt batteries in series. maintained in groups of two.
divide the central system into multiple TKT41 Central Battery Systems have,
independent regions.
DIMENSIONS
30
419
244
24
Teknoware Emergency Lighting Product Catalogue
TYPE OF THE CBS
Product Max Outputs Output circuit Max load, Max Space for Max Weight
code input maintained total batteries battery (kg)
power lights load, 1 h inside capacity
(mains) duration the unit
TKT3122 300 VA 4x Can be set in steps of two circuits / total 4 circuits: 250 VA 290 W 2 x 12 V / 24 Ah 12,5
120 W • maintained circuits max 120 W / circuit 24 Ah
• non-maintained circuits max 190 W / circuit
TKT4144 1300 VA 8x Can be set in steps of two circuits / total 8 circuits: 1050 VA 1370 W 2 x 12 V / 100 Ah 24,0
TKT4188 1300 VA 16 x Can be set in steps of two circuits / total 16 circuits: 1050 VA 1370 W 2 x 12 V / 100 Ah 24,5
120 W • maintained circuits max 120 W / circuit 38 Ah
• non-maintained circuits max 190 W / circuit
OPTIONAL FEATURES
Product code Product description For
25
Teknoware Emergency Lighting Product Catalogue
BATTERY CABINETS IP
44
26
Teknoware Emergency Lighting Product Catalogue
Sl.No. Model Number Battery Rating Cabinet Size
(WxDxH) mm
Specifications
Frame thickness: 2 mm
Door thickness: 2 mm
Applications
Standards
27
Teknoware Emergency Lighting Product Catalogue
BATTERIES
Teknoware batteries are maintenance free, sealed, leak proof, lead acid gas recombination type battery with following system
features:
• AGM technology
Voltage (V) Capacity Dimension (mm) Total Height Weight (kgs) Battery cabinet dimension
(Ah) (W x D x H) mm
Length Width Height
28
Teknoware Emergency Lighting Product Catalogue
REMOTE SWITCHES IP
20
Phase Controller Modules enable to control 1-4 phases of local fuse boxes. There are 2 pieces of potential free contact relays, which will be
activated, when one or more controlled phases drop or is missing. Relay outputs can be connected in NO or NC and it is possible to control other
devices with them.
CBU CBU
29
Teknoware Emergency Lighting Product Catalogue
SWITCH CONTROLLER IP
20
*)
POSSIBLE TO COMPATIBLE
ACTIVATE THE WITH ALL
LUMINAIRES TEKNOWARE
CONNECTED TO CENTRAL
THE CENTRAL BATTERY
BATTERY SYSTEMS SYSTEMS
USING EITHER A HAVING A
LIGHT SWITCH 230 VAC/DC
OR A TIMER OUTPUT
Utilising the Switch Controller TST28xx, In this case, all the luminaires will be lit Switch Controller has also a dimming
it is possible under normal mode to automatically whether the light switch is control output, which can be used to
activate the luminaires connected to the on or off. dim the light during emergency mode.
Central Battery System using either a The Switch Controller TST28xxx is The control output is compatible with
light switch or a timer. compatible with all Teknoware Central electronic ballasts having a 1-10 V
During an emergency mode, the Switch Battery Systems having a 230 VAC/DC dimming control input according to
Controller switches the supply to take output. It can also be used with the Local IEC 60929.
place from the Central Battery System. Controller.
SWITCH CONTROLLER
TST2801/ TST2803(B)
TST2800
60 117 3,5
213
20 160
20
38 38
82 127
5,5
60
127 213
107 75 75
117
TST2802 TST8501
123
117
86 65 150
32 32
43 43
44
150
4 140
123
44
5,5
86
107
30
Teknoware Emergency Lighting Product Catalogue
SWITCH CONTROLLER
TST2800 230 V 250 VA Inside a distribution panel • in normal mode the luminaires take their supply from the
AC/DC light switch
• controls emergency lights by normal light switch
• a dimming control output 1-10 V
TST2801 230 V 250 VA With the junction box enclosure • in normal mode the luminaires take their supply from the
AC/DC (IP20) for independent installation light switch
• controls emergency lights by normal light switch
• a dimming control output 1-10 V
TST2802 230 V 1400 VA Inside a distribution panel • controls emergency lights from Central Battery System
AC/DC • a dimming control output 1-10 V
TST2803 230 V 1400 VA With the junction box enclosure • controls emergency lights from Central Battery System
AC/DC (IP20) for independent installation • a dimming control output 1-10 V
TST2803B 230 V 1400 VA With the junction box enclosure • in normal mode the luminaires take their supply from the
AC/DC (IP20) for independent installation light switch
• controls emergency lights by normal light switch
• a dimming control output 1-10 V
TST8501 230 V 1000 VA Inside a distribution panel • controls emergency lights from Central Battery System
AC/DC • inverting function in AC
31
Teknoware Emergency Lighting Product Catalogue
LOCAL CONTROLLER IP
20
*)
ENABLES LOCAL
EXTRA SAFETY CONTROL OF
WITH LOWER EMERGENCY
INSTALLATION LIGHTS IN
COSTS CENTRAL BATTERY
SYSTEMS
Local Controller enables local control Local Controller is connected to the connected luminaires remain lit, after the
of emergency lights in central battery emergency supply cabling between normal power supply has been restored
systems. It monitors the local supply, and the Central Battery System, and the Both maintained and non-maintained
controls the emergency lights connected luminaires. Its monitoring inputs are emergency lights can be connected to
to it. It provides two remarkable connected to the mains supply of the the same circuit wiring.
advantages: local general lighting, and it can monitor
up to 3 phases independently. If any Teknoware’s addressable luminaires (K
• Local voltage breakdown switches on in the end of the product code) can be
of the monitoring inputs detect supply
the non-maintained emergency lights, installed as non-maintained, when used
failure, Local Controller sends a message
even if the supply to the Central Battery with Local Controller.
via supply cable to the non-maintained
System remains.
lights and they switch themselves on. Models TS90695, TS90696, TST6803,
When the supply recovers, the normal TST6804 and TST6805 have a relay
• Both maintained and non-maintained
operation returns automatically. output for controlling other devices. The
emergency lights can be connected
to the same circuit. This eliminates Models TS90695, TS90696, TST6803, relay output changes status, when Local
separate cabling for maintained and TST6804 and TST6805 also have a Controller is activated.
non-maintained lights. switch control input and a potentiometer,
for setting a time delay, so that the
43
43
60
123
123
5,5
60
86
38 38
107
117
45 45
127 82 127
89
127 213
75 75
32
Teknoware Emergency Lighting Product Catalogue
CENTRAL BATTERY SYSTEMS
| Data moves in circuit cables
| The Local Controller enables controlling local mains supply
LOCAL CONTROLLER
Product code Input Power Installation Feature
voltage
TS90686 230 V 250 VA With the junction box enclosure • 1-3-phase monitoring,
(IP20) for independent installation • Controlling the non-maintained lights through the supply cabling
TS90695 230 V 250 VA Inside a distribution panel • 1-3-phase monitoring /230 V control input,
• Controlling the non-maintained lights through the supply cabling,
• Switch control input,
• Relay contact output from 1-3-phase monitoring (NC/NO),
• 0-15 min adjustable delay for return to mains operations
TS90696 230 V 250 VA With the junction box enclosure • 1-3-phase monitoring /230 V control input,,
(IP20) for independent installation • Controlling the non-maintained lights through the supply cabling,
• Switch control input,
• Relay contact output from 1-3-phase monitoring (NC/NO)
• 0-15 min adjustable delay for return to mains operations
TST6801 230 V 1400 VA Inside a distribution panel, • 1-3-phase monitoring /230 V control input,
DIN rail compatible • Controlling the non-maintained lights through the supply cabling
TST6802 230 V 1400 VA With the junction box enclosure • 1-3-phase monitoring /230 V control input,
(IP20) for independent installation • Controlling the non-maintained lights through the supply cabling
TST6803 230 V 1400 VA Inside a distribution panel • 1-3-phase monitoring /230 V control input,
• Controlling the non-maintained lights through the supply cabling,
• Switch control input,
• Relay contact output from 1-3-phase monitoring (NC/NO),
• 0-15 min adjustable delay for return to mains operations
TST6804 230 V 1400 VA With the junction box enclosure • 1-3-phase monitoring /230 V control input,
(IP20) for independent installation • Controlling the non-maintained lights through the supply cabling,
• Switch control input,
• Relay contact output from 1/3-phase monitoring (NC/NO)
• 0-15 min adjustable delay for return to mains operations
TST6805 230 V 1400 VA Inside a distribution panel • Intelligent Controller (IC) compatible,
• 1-3-phase monitoring /230 V control input,
• Controlling the non-maintained lights through the supply cabling,
• Switch control input,
• Relay contact output from 1-3-phase monitoring (NC/NO),
• 0-15 min adjustable delay for return to mains operations
with 1 minute spacing with DIP Switch
33
Teknoware Emergency Lighting Product Catalogue
SEPARATE ADDRESS MODULES
TS98253 100 VA 1 VA / 1 W 10±5 mA 230 V DC Maintained / • Operation can be selected by a DIP switch, 98 x 41 x 21
non-maintained • IC, C, Local Controller
TS98253B 100 VA 1 VA / 1 W 10±5 mA 230 V DC Maintained / • Operation can be selected by a DIP switch, 142 x 30 x 25
non-maintained • IC, C, Local Controller, SLIM model
TS98254 200 VA 1 VA / 1 W 10±5 mA 230 V DC Maintained / • Operation can be selected by a DIP switch, 150 x 44 x 32
non-maintained • IC, C, Local Controller
TS98255 625 VA 2 VA / 2 W 400 mA 230 V DC Maintained / • Operation can be selected by a DIP switch, 150 x 44 x 32
non-maintained • C, Local Controller
TS98281 200 VA 1,5 VA / 10±5 mA 220-240 V, Maintained / • Operation can be selected by a DIP switch 150 x 43 x 32
1,5 W 50/60 Hz non-maintained • Phase input
AC,DC • Switch control output,
• IC, C, Local Controller
34
Teknoware Emergency Lighting Product Catalogue
SEPARATE ADDRESS MODULES - CONNECTIONS
Central
Battery
Unit
DALI BALLAST
DALI BALLAST
TS98271 is a DALI-compatible address module, connected to a luminaire. It simulates the function of DALI-master.
Setting of luminous output: 10-100% manually. Saves and resets data of the DALI address module in its memory.
Central
Batteries battery
unit
phase input
phase output
TS98281 Electronic
ballast
Local e.g.
distribution light switch
board
TS98281 is an address module, with switch and supply monitoring input. Function is similar to the Local Controller and Switch Controller.
TST98281 address module is used with one luminaire and with one controlled phase.
35
Teknoware Emergency Lighting Product Catalogue
INTELLIGENT CONTROLLER (IC)
Teknoware’s IC (Intelligent Controller) The IC system consists of the following in the memory of the Central Battery
system enables a large amount of components: System, thus, there is no need for the PC
different options, to turn the non- • TKT65C, TKT66C, TKT67C or TKT68C, except during the programming.
maintained emergency lights ON and addressable Tapsa Control Central Any input of any of the IC Input Modules
OFF, by using voltage inputs, which can Battery System can be set to control any luminaire or
be freely chosen. luminaires, in any circuit. Furthermore,
At the same time, the voltage of several • addressable, K-type emergency Lights logical switches can be programmed in
fuse boxes or general lighting can be the IC system. The inputs of an IC Input
monitored. When the voltage in one • TST8801, IC Input Module Module can form groups, which can
or several fuse boxes drops out, the (up to 31 pcs in a single IC system) control the luminaires.
selected emergency lights are turned These logical switches work so, that
ON, with AC voltage. • TST6x5x, IC Interface for the Central
when any switch of any group is
Battery System (including a PC
In one IC Input Module, there are eight activated, the luminaires assigned for
software, with which the IC system is
voltage inputs, each of which have it switch ON. Single inputs and logical
programmed)
their own, galvanic separated L and N switches can also be used inverted: when
connection. Each IC Input Module has The programming of the IC system a voltage is fed to an input, the luminaire
its own address, which is set by a DIP settings and the emergency lights is switches OFF.
switch. done, using the PC software, during the
implementation, via a USB port, into the
IC Interface. The programming is saved
36
Teknoware Emergency Lighting Product Catalogue
WEBCM & WEBACM
WebCM enables central monitoring of
the central battery systems via Internet.
The system consists of a Web module
connected to a Central Battery System.
Each Central Battery System has an
individual IP address and an ordinary
Internet browser serves as a user
interface.
mains supply
Tapsa
Control
PC /IP CBU outputs
TCP/IP CP
T
Battery
INTERNET Cabinet
PC IP
P/
TC
37
Teknoware Emergency Lighting Product Catalogue
ACM
Teknoware’s Advanced Central
Monitoring (ACM), is a central
monitoring system, utilising a separate
network, for the Tapsa Control Central
Battery Systems. ACM utilises RS485
protocol, which makes communications
possible even if the distance between
the Central Battery System and the
computer is up to 1 km.
ACM’s PC Software screen displays the
status of all the Central Battery Systems
and the luminaires connected to them.
The user may also run battery and light
tests. ACM saves the test log book
information automatically as per the
requirements of fire safety authorities.
By using the computer equipped with
ACM, it is possible to connect, e.g., to a
BACnet building automation system
Central
CAT 5/6
Battery
Unit
Central
Battery
CAT 5/6
Unit
Central
Battery
Unit
CAT 5/6
Central
Battery Power supply cable
PC
Unit
SB /6
T5
U
CA
Modem
= non-maintained emergency luminaire
38
Teknoware Emergency Lighting Product Catalogue
BACNET
The BACnet module in the Central
Battery System allows it to be connected
directly to a building automation
system. The BACnet application make
it possible to access all the information
supplied by the Central Battery System.
In the BACnet interface, information is
transferred as BACnet objects.
Ethernet switch
Central
TCP / IP NETWORK CAT 5/6 Battery
Unit
CAT 5/6
Central
Battery Power supply cable
Unit
39
Teknoware Emergency Lighting Product Catalogue
LON
LON central monitoring solution is
Product Product desc- For based on the COBA Building Operating
code ription
System, which offers a standard open
TST6722 LON Interface TKT67xxC platform for building automation and
TST6822 LON Interface TKT68xxC security systems.
TST6622 LON Interface TKT66xxC The LON interface also makes it possible
TST6522 LON Interface TKT65xxC to access all information from the field,
XKT2301 LON Interface TK23xxC in a centralised manner.
| Also a separate COBA Software is needed for the PC. The system consists of an open LON
network and a server, which link the
Central Battery Systems together.
Central
battery
2C LON
unit
Central
battery
2C LON
unit
Central
battery
unit
2C LON
Central
battery Power supply cable
PC
unit
SB N
U
LO
2C
TC
LNI
P
/
N
IP
40
Teknoware Emergency Lighting Product Catalogue
BCM UNIT
Product code Product description Supply voltage Casing Temperature range Input fuse
TST1809 Basic Central Monitoring Unit 1 ~230 V AC 50 Hz IP44 +10... 30 °C Glass-tube fuse 1 AT 5 x 20mm
with Printer
TST1809B Basic Central Monitoring 1 ~230 V AC 50 Hz IP44 +10... 30 °C Glass-tube fuse 1 AT 5 x 20mm
Unit without Printer
Product code Product description For Basic Central Monitoring unit (BCM) is
possible to be connected in all Central
319
260
192
Central
69
260
68
130
Battery
Unit
Central
Battery
Unit
Central
Battery
BCM
Unit
3-c ta cable
o r e da
Central
Battery Power supply cable
Unit
41
Teknoware Emergency Lighting Product Catalogue
ESCAP SELF-CONTAINED LIGHTS
WITH SUPER CAPACITOR BACKUP
Cutting-edge technology for Teknoware solves the battery problem ESCAP adds speed to safety
emergency lighting of self-contained lights, by replacing Recharging time in ESCAP luminaires
For emergency lighting there have been, the batteries with ESCAP technology. is significantly shorter, than in self-
and still are, only two basic solutions, Using LED ESCAP luminaires and contained emergency and exit lights,
both of which are determined by the the wireless Aalto Control remote with traditional battery.
location of the battery: management system together, it is
possible to create a solution, where Super capacitors cannot replace
the advantages of both central battery batteries directly, due to their different
• Central battery systems, where a voltage characteristics. A super
and self-contained systems can be
central battery bank powers several capacitor’s charge voltage and current
combined, and the disadvantages
luminaires must be controlled accurately. As wide
eliminated.
relative voltage range as possible must
• Self-contained systems, where each be utilised, when the super capacitor is
luminaire has its own battery Super capacitors replace batteries discharged. Teknoware has developed
Each alternative offers certain special power converter technology to
ESCAP is a product line, which
advantages and disadvantages. Central overcome these challenges. As a result,
combines capacitive energy storage
battery systems offer the advantage of it has been possible to utilise this quickly
with the latest LED technology in self-
easy testing and maintenance, whereas advancing technology in practical
contained emergency and exit lights.
self-contained systems offer flexible applications.
Unlike traditional applications, the
installations, due to simpler cabling.
energy required during a power outage
The definitive disadvantage of self-
in ESCAP luminaires is not stored in
contained systems has been the limited
traditional electrochemical batteries, but
lifespan of batteries. The changing of the
in very high capacitance, low-voltage
batteries could be very labour intensive,
super capacitors.
as the batteries are located in possibly
hundreds of luminaires.
42
Teknoware Emergency Lighting Product Catalogue
UPM Headquarter in Helsinki, Finland, uses ESCAP luminaires with Aalto Control
43
Teknoware Emergency Lighting Product Catalogue
AALTO CONTROL WIRELESS MONITORING
UNIT FOR WALL-MOUNTING
Aalto Control Wireless Monitoring Unit (TST5108)
With the wall-mounted Aalto Control Wireless Monitoring Unit (WMU), it is possible to monitor and control self-contained Aalto
Control emergency and exit lights, equipped with Super Capacitors, or traditional batteries. Aalto Control WMU enables the local,
wireless monitoring of emergency and exit lights. Aalto Control WMU is installed on the wall, equipped with a 7” touch screen, and
an easy-to-use graphical user interface. Typical indoor luminaire to luminaire and Aalto Control Wireless Monitoring Unit to luminaire
is up to 40 m. Up to 500 luminaires can be connected to a single Aalto Control WMU system.
TST5108
TST5108 DIMENSIONS
282 38
ED
OUNT
W WALL-MROL UNIT
N E CON T
A ALTO
7“
NDLY
S E R - F RIE E E N
U H S CR
343 343
TOUC
C
RAP
O N E ED F O
N
0
TO 5 0
N I T O RS U P
M O A IR E S
L U MIN 282
38
TST5103(B) Aalto Control Wireless / Ethernet Coordinator (2-pin ”Europlug”), (TST5103B=3-pin ”UK-plug”)
TST5107 Aalto Control Relay Output Module, a module which enables the Aalto Control system to control a relay-based device,
such as an alarm device, or an indicator light
• Prohibition times can be defined for luminaire and battery tests USA (FCC Part 15.247)
• Various user levels can be defined for different users Industry Canada (IC)
• Saves the data and location of the connected luminaires in the data base Europe (CE) ETSI
• A Relay Output makes it possible to tranfer a fault alarm to external systems RoHS Compatible
Internet node
(modem, router, switch etc.)
2 3 INTERNET
45
Teknoware Emergency Lighting Product Catalogue
AALTO CONTROL WIRELESS CENTRAL
MONITORING FOR SELF-CONTAINED
LUMINAIRES
PC SYSTEM
WIRELESS CENTRAL MONITORING FOR SELF-CONTAINED EMERGENCY AND EXIT LIGHTS
Aalto Control provides a wireless Installation is simple, and the luminaires is as robust and resistant to failures as any
central monitoring for self-contained can be easily positioned, even during other self-contained light system. Aalto
lights. There is no need to connect the renovations. Each luminaire is a node, Control lights always include Lumi Test.
luminaires with data cables. The only receiving and transmitting the signal to Product codes of Aalto Control lights
requirement is that each individual other luminaires. The signal penetrates end in letter A.
luminaire has a local power supply, like normal walls, doors and floors easily,
any standard self-contained light. All the and climbs stairways. The network is The new Aalto Control 4.0 enables
benefits of the self-contained lights are used only for collecting information and Central remote monitoring through
preserved, and each luminare functions does not affect the operation of the several Aalto Wireless / Ethernet
independently. luminaires. For this reason, Aalto Control Coordinators (Max 30 pcs), from one
location.
AALTO WALL ROUTER
EXPANSION OF
THE SYSTEM
Several Wireless /
WIRELESS / ETHERNET
Ethernet Coordinators
EVERYTHING AT A GLANCE can be included in one
COORDINATOR
Aalto Control software collects data Aalto Control system
In the new Aalto Control 4.0 (Max 30 pieces).
from all the luminaires. Software has one
system, the PC and Wireless /
logbook, which saves all test data from This is useful when e.g.
Ethernet Coordinator can be
every luminaire. Software has a very the system is desired
positioned freely, e.g. in separate
user-friendly map, which clearly shows, to be divided in
rooms or buildings.
what is the status of the luminaires, at different sections, e.g.
The communication between the moment. Adding or moving the separate buildings.
PC and Coordinators is done via luminaires is very simple and easy.
Ethernet connection.
46
Teknoware Emergency Lighting Product Catalogue
AALTO CONTROL PC SYSTEM LAYOUT
TYPICAL AALTO CONTROL PC SYSTEM
Exit light
Emergency light
Coordinator
Switch / Router
PC
Ethernet cabling
(existing Ethernet cabling
can be used)
Exit light
Internet
Emergency light
Coordinator
Internet node
(modem, router, switch etc.)
PC
Ethernet cabling
(existing Ethernet cabling
can be used)
Exit light
Emergency light
Coordinator
PC
Ethernet cabling
(existing Ethernet cabling
can be used)
47
Teknoware Emergency Lighting Product Catalogue
AALTO CONTROL PC SYSTEM FEATURES
PC SYSTEM
TECHNICAL DATA
Indoor range up to 40 m
CERTIFICATION OF WIRELESS
TECHNOLOGY
RoHS Compatible
48
Teknoware Emergency Lighting Product Catalogue
Product Product description
code
TST5107 Aalto Control Relay Output Module, a module which enables the Aalto system to control a relay-based device, such as an alarm device,
or an indicator light
Aalto Wireless/ Ethernet Coordinator Aalto Control Exit Light Aalto Control Aalto Wall Router
Emergency Light
Symbols
Slow blinking
(1 Hz, once / second)
Fast blinking
(2 Hz, twice / second)
OFF
ON
PAN ID Code Control lights are added afterwards, customer doesn’t specify any code, the
(= Aalto Control network ID) PAN ID Code of the existing Aalto code is automatically set to zero (0), at
Control network needs to be Teknoware´s factory.
Aalto Control lights can be defined to
communicated to Teknoware. This
work with a certain Aalto Wireless /
way, PAN ID Codes can be set in the
Ethernet Coordinator, with the help of
new Aalto Control lights already at
PAN ID Code (Network Identification
Teknoware’s factory.
Code). This is useful, for example, if
an Aalto Control system of a big site, The customer also has the possibility
with several Aalto Wireless / Ethernet to specify PAN ID Code for Aalto
Coordinators, needs to be divided in Control network. PAN ID Code can
separate networks. include maximum four (4) digits and
contain letters (a-f) and/or numbers. The PAN ID / RFID stickers, which will be delivered
If there already is an Aalto Control with Aalto Control luminaires
code can be, for example, 123F. If the
system in a building, and new Aalto
49
Teknoware Emergency Lighting Product Catalogue
REFERENCES
50
Teknoware Emergency Lighting Product Catalogue
EXIT AND EMERGENCY LIGHTS
EXIT LIGHTS
ESC 10 | TW802, TW850, TWS85, TW844 60-65
SILVER | TWT65, TWT66, TWT67, TWT68 66-73
ESC 6L | TWT62, TWS62 74
ESC 6 | TWT60, TWS60 76
ESC 29 | TWT29, TWS29 78
ESC 96 | TWT96 80
LINESPOT II LOWBAY | TWT99, TWT14 82, 86
LINESPOT II MIDBAY | TWT88 84
LINESPOT | TWT50, TWS50 88
ZONESPOT II LOWBAY | TWT92, TWT04 90, 96
ZONESPOT II MIDBAY | TWT93 92
EMERGENCY LIGHTS
ZONESPOT II HIGHBAY | TWT84 94
SAFE 29 | TWT29, TWS29 98
SAFE 82 | TWT82 100
SAFE 6 | TWT82 102
TRISPOT | TWT75, TWT76 104
SLIMSPOT | TWT97, TWS97 106
MINI LINESPOT | TWT73, TWS73 108
SAFE 95 | TWT95 110
HANDRAIL EMERGENCY LIGHT | TWT91 112
51
Teknoware Emergency Lighting Product Catalogue
ESC 90 EN
60598-2-22
EN
1838
-o- LED IP
44
RAL
9003
25 m
CEILING
AND WALL
MOUNTING
AS STANDARD
283
120 36 120
268 40 40 13 5 64 21 18 17 13 2215 120 18 13
5 64 21
268 5 64 21 40
202 187
125 125
21 102
RECESS MOUNTING
64 5 326 94
120
64
52
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
TWT9053WA 220-240 V, 5,3 VA 3 h battery + Aalto -5…+30°C 2/3 x 2,5 mm2 0,53
50/60 Hz AC -o-
EXIT LIGHTS
PICTOGRAMS SPECIAL PICTOGRAMS
Product Pictogram Product description Product Pictogram Product description
code code
PB9007 White label (1 pc supplied with the light) PB9006H Down arrow, unobstructed escape route with lift
PB401 Set of pictograms PB9005H Right arrow, unobstructed escape route with lift
(PB9006 x 2, PB9005 x 1, PB9004 x 1)
PB9004H Left arrow, unobstructed escape route with lift
| Pictograms in the table are 1-sided PB9020 Fire Extinguisher
| Custom Pictogram options available
PB9003A EXIT, Down arrow
85 326
297
275
40 7
115
5,5 94 45
Max. 1000mm
53
Teknoware Emergency Lighting Product Catalogue
ESC 80 EN
60598-2-22
EN
1838
-o- LED IP
44
RAL
9003
20 m 26 m 30 m
CEILING
AND WALL
MOUNTING
AS STANDARD
DIMENSIONS
20 M 120
40 5 64 21
268
28 18
185
100
26 M
268 21 102
64 5
120
217
130
30 M
268
237
150
54
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
EXIT LIGHTS
SEPARATELY ORDERED PICTOGRAMS ACCESSORIES
Product code Pictogram Product description Viewing distance Product code Product
PBV80202E Down arrow 20 m TWT9002 Flag bracket
PBV80201E Left/right arrow 20 m TWT9000 Suspension bracket
XWT8003 White label 20 m TW77507B Shock protecting cover
(dims: X=320, Y=165, Z=305, A=340)
PBV80262E Down arrow 26 m
85
40
115
5,5
Max. 1000mm
283
36
15
55
Teknoware Emergency Lighting Product Catalogue
ESC 80 EN
60598-2-22
EN
1838
-o- LED IP
44
RAL
9003
20 m 26 m 30 m
RECESS
MOUNTING
WITH A
SEPARATE
FRAME
RECESS MOUNTING
326 83
69
328 318
299 276
275
7
83 45 88 82
| Aperture for recess mounting of centrally | Aperture for recess mounting of centrally
supplied lights: 45 mm x 275 mm (TWT8001) supplied lights: 45 mm x 275 mm (TWT8001)
| Aperture for recess mounting of self-contained | Aperture for recess mounting of self-contained
lights: 53 mm x 275 mm (TWT8001B) lights: 53 mm x 275 mm (TWT8001B)
56
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
EXIT LIGHTS
SEPARATELY ORDERED PICTOGRAMS ACCESSORIES
Product code Pictogram Product description Viewing distance Product code Product
PBV80202E Down arrow 20 m TWT8001 Recess mounting frame for centrally
supplied lights, (Mounting with screws)
PBV80201E Left/right arrow 20 m
TWT8006 Recess mounting frame for centrally
XWT8003 White label 20 m supplied lights, (Mounting with springs)
PBV80262E Down arrow 26 m TWT8001B Recess mounting frame for self-contained
lights, (Mounting with screws)
PBV80261E Left/right arrow 26 m
TWT8006B Recess mounting frame for self-contained
XWT8002 White label 26 m
lights, (Mounting with springs)
PBV80302E Down arrow 30 m
TW77507B Shock protecting cover
PBV80301E Left/right arrow 30 m (dims: X=320, Y=165, Z=305, A=340)
57
Teknoware Emergency Lighting Product Catalogue
ESC 81 EN
60598-2-22
EN
1838
-o- LED IP
44
RAL
9003
40 m 60 m
CEILING
AND WALL
MOUNTING
AS STANDARD
DIMENSIONS
37
287
200
60 M 21 102
405
268 64 5
120
RECESS MOUNTING
468 83
69
386
305
30 m
-o- LED
TWT8151W 220-240 V, 5,5 VA/ CBS -30…+50°C 2/3 x 2,5 mm2 1,35
50/60 Hz AC,DC 3,2 W -o-
EXIT LIGHTS
SEPARATELY ORDERED PICTOGRAMS
Product code Pictogram Product description Viewing distance
ACCESSORIES
Product code Product
85 468
439
415
40 7
115
5,5 83 45
Max. 1000mm
59
Teknoware Emergency Lighting Product Catalogue
ESC 10 EN
60598-2-22
EN
1838
-o- LED IP
20
AL
30 m
A BRACKET
IS ALWAYS
NEEDED
45
70
122
287
287 272 272
251
215 30 51
167 21
21
68
33
30 51
33
324 76 369
8 324
94
60
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
Product code Nominal Max input power Light Operation Temperature Electrical installation Weight
supply voltage source mode range (kg)
EXIT LIGHTS
TWT8553WA 220-240 V, 9 VA LED 3 h battery -5…+30°C 3 x 2,5 mm2 2,9
50/60 Hz AC + Aalto -o-
ACCESSORIES
Product code Product
61
Teknoware Emergency Lighting Product Catalogue
ESC 10 EN
60598-2-22
EN
1838
-o- LED IP
20
AL
40 m
A BRACKET
IS ALWAYS
NEEDED
28 239 68 76
27 8
70
122 45
311
326 311
326
324
21 215
167 51 30
68
51 30 21
33
33
62
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
EXIT LIGHTS
supply voltage source mode (kg)
ACCESSORIES
Product code Product
63
Teknoware Emergency Lighting Product Catalogue
ESC 10 EN
60598-2-22
EN
1838
-o- LED IP
20
AL
30 m
FOR
WALL
MOUNTING
DIMENSIONS
277
6 265
277 95
21 30
52 52 41
71
219 219
219
64
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
EXIT LIGHTS
Product code Pictogram Product description
ACCESSORIES
Product code Product
65
Teknoware Emergency Lighting Product Catalogue
SILVER EN
60598-2-22
EN
1838
-o- LED IP
20
RAL
9006
30 m
CEILING MOUNTING
TWT6551WK
SUSPENSION
MOUNTING
SUSPENSION MOUNTING
TWT6551WKL
Metal framed, stylish Silver LED exit lights
are especialy suited for areas requiring
truly elegant exit signs.
DIMENSIONS
CENTRALLY SUPPLIED LIGHTS SELF-CONTAINED LIGHTS
CEILING MOUNTING CEILING MOUNTING
286 282
53 62
300
350
350
SUSPENSION MOUNTING SUSPENSION MOUNTING
282 98
286
60 Up to 1200
57
Up to 1200
56
199 150
201 150
300 14
350
350 14 5 21
5 50 30
17
19 154
15
65
20 65 21
30
66
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
TWT6551WK 220-240 V, 10,4 VA / CBS / C -30… 3 x 2,5 mm2 1,9 Ceiling mounting
50/60 Hz AC,DC 6,5 W +50°C -o- (surface mounting)
TWS6592WA 220-240 V, 7,6 VA 1 h Escap + Aalto -25… 3 x 2,5 mm2 2,8 Ceiling mounting
50/60 Hz AC +35°C -o- (surface mounting)
EXIT LIGHTS
TWS6592WAL 220-240 V, 7,6 VA 1 h Escap + Aalto -25… 3 x 2,5 mm2 3,0 Suspension
50/60 Hz AC +35°C -o- mounting
TWS6592WM 220-240 V, 7,6 VA 1 h Escap + M -25… 3 x 2,5 mm2 2,8 Ceiling mounting
50/60 Hz AC +35°C -o- (surface mounting)
67
Teknoware Emergency Lighting Product Catalogue
SILVER EN
60598-2-22
EN
1838
-o- LED IP
20
RAL
9006
30 m
FLAG
MOUNTING
DIMENSIONS
CENTRALLY SUPPLIED LIGHTS SELF-CONTAINED LIGHTS
52 53
44
399 14 30
16
14
401 102
21
87 300
42 162
5 200 150 203
51 348 15 30
20
60
21 58
53
68
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
TWT6651WK 220-240 V, 10,4 VA / CBS / C -30… 3 x 2,5 mm2 1,7 Flag mounting
50/60 Hz AC,DC 6,5 W +50°C -o-
TWS6692WA 220-240 V, 7,6 VA 1 h Escap -25… 3 x 2,5 mm2 2,5 Flag mounting
50/60 Hz AC + Aalto +35°C -o-
TWS6692WM 220-240 V, 7,6 VA 1 h Escap -25… 3 x 2,5 mm2 2,5 Flag mounting
50/60 Hz AC +M +35°C -o-
EXIT LIGHTS
SEPARATELY ORDERED PICTOGRAMS
Product code Pictogram Product description
69
Teknoware Emergency Lighting Product Catalogue
SILVER EN
60598-2-22
EN
1838
-o- LED IP
20
RAL
9006
30 m
WALL
MOUNTING
DIMENSIONS
CENTRALLY SUPPLIED LIGHTS SELF-CONTAINED LIGHTS
238
350 237 174
86 350
30
4 21
16
4 136
200 150 102 200 150 171 40
16
30 4 5 21
203
202 203
55 39 56 41
70
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
TWT6751WK 220-240 V, 10,4 VA / CBS / C -30… 3 x 2,5 mm2 1,8 Wall mounting, either
50/60 Hz AC,DC 6,5 W +50°C -o- surface or semi-
recessed mounting
TWS6792WA 220-240 V, 7,6 VA 1 h Escap -25… 3 x 2,5 mm2 2,6 Wall mounting, either
EXIT LIGHTS
50/60 Hz AC + Aalto +35°C -o- surface or semi-
recessed mounting
TWS6792WM 220-240 V, 7,6 VA 1 h Escap -25… 3 x 2,5 mm2 2,6 Wall mounting, either
50/60 Hz AC +M +35°C -o- surface or semi-
recessed mounting
71
Teknoware Emergency Lighting Product Catalogue
SILVER EN
60598-2-22
EN
1838
-o- LED IP
20
RAL
9006
30 m
RECESS
MOUNTING
DIMENSIONS
CENTRALLY SUPPLIED LIGHTS SELF-CONTAINED LIGHTS
412 84
52 410 84
359 20
20 355
11 355 26 52
31 34
64
21
23 11
198 150
150 209
348 14
300 14
35 210 350
35 210
25
66
73 21 4 8
21 4
72
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
TWT6851WK 220-240 V, 10,4 VA / CBS / C -30… 3 x 2,5 mm2 2,3 Recess mounting
50/60 Hz AC,DC 6,5 W +50°C -o-
TWS6892WA 220-240 V, 7,6 VA 1 h Escap + Aalto -25… 3 x 2,5 mm2 2,9 Recess mounting
EXIT LIGHTS
50/60 Hz AC +35°C -o-
TWS6892WM 220-240 V, 7,6 VA 1 h Escap + M -25… 3 x 2,5 mm2 2,9 Recess mounting
50/60 Hz AC +35°C -o-
73
Teknoware Emergency Lighting Product Catalogue
ESC 6L EN
60598-2-22
EN
1838
-o- LED IP
44
RAL
9003
40 m
WALL AND
CEILING
MOUNTING
AS
STANDARD
CEILING MOUNTING
455
75 455
21 30
295 295
295
455
404 4,5
21 30
FLAG MOUNTING
37 XWT6213B
75 40
462
7
74
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
TWT6271W 24-230 V, 24 V= 7,3 VA / 4,6 W LED CBS -30…+50°C 24 V= 2 x 2,5 mm2 1,6
50/60 Hz AC,DC 230 V= 14,6 VA / 5 W 230 V=3 x 2,5 mm2
-o-
TWT6251WK 220-230 V, 8,3 VA / 4,6 W LED CBS / C -30…+50°C 3 x 2,5 mm2 1,6
50/60 Hz AC,DC + IC -o-
EXIT LIGHTS
SEPARATELY ORDERED PICTOGRAMS
Product code Pictogram Product description
ACCESSORIES
Product code Product
420
341
57
75
Teknoware Emergency Lighting Product Catalogue
ESC 6 EN
60598-2-22
EN
1838
-o- LED IP
44
RAL
9003
CEILING,
WALL
AND FLAG
22 M
MOUNTING
VIEWING
AS
DISTANCE
STANDARD
267 63
20 79 281
121 24 20 21 17 14
31
65
21
18 21 23 63
18
124
76
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
TWT6071WS 24-230 V, 24 V= 7,5 VA / 4 W LED CBS -30…+50°C 24 V= 2/3 x 2,5 mm2 0,8
50/60 Hz AC,DC 230 V= 11 VA / 4 W 230 V= 2/3 x 2,5 mm2
-o-
TWT6051WK 220-230 V, 8,3 VA / 4,6 W LED CBS / C + IC -30…+50°C 3 x 2,5 mm2 0,8
50/60 Hz AC,DC -o-
TWT6051WKS 220-230 V, 8,3 VA / 4,6 W LED CBS / C + IC -30…+50°C 2/3 x 2,5 mm2 0,8
50/60 Hz AC,DC -o-
EXIT LIGHTS
SELF-CONTAINED EXIT LIGHTS
Product code Nominal supply Input power Light Operation Temperature Electrical installation Weight
voltage source mode range (kg)
SUSPENSION BRACKET
TW77504C
85
5,5
6 214
77
Teknoware Emergency Lighting Product Catalogue
ESC 29 EN
60598-2-22
EN
1838
-o- IP
65
RAL
9003
30 m
WALL AND
SURFACE
MOUNTING
AS STANDARD
DIMENSIONS
341 341
270
53 21
32
189 94
189
80
78
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
TWT2971W 24 - 230 V 24 V= 7,3 VA /4,7 W LED CBS -30… 24 V= 2 x 2,5 mm2 1,2
50/60 Hz AC,DC 230 V=15,4 VA /5,3 W +50°C 230 V=3 x 2,5 mm2
-o-
TWT2951WK 220-240 V, 8,3 VA / 4,6 W LED CBS + IC -30… 3 x 2,5 mm2 1,2
50/60 Hz AC,DC +50°C -o-
Product code Nominal Max input power Light Operation Temperature Electrical installation Weight
supply voltage source mode range (kg)
EXIT LIGHTS
TWS2992WM 220-240 V, 8 VA LED 1 h Escap + M -25… 3 x 2,5 mm2 1,5
50/60 Hz AC +35°C -o-
ACCESSORIES
Product code Product
TWT2901 Wall mounting reflector for TWT29 lights with 9 W fluorescent lamp
5,5
47 390
317
390
180
208
60
79
Teknoware Emergency Lighting Product Catalogue
ESC 96 EN
60598-2-22
EN
1838
-o- LED IP
67 24 m
FOR
SURFACE
MOUNTING
DIMENSIONS
304
126 7
126 120 80
126
280
304
126
80
Teknoware Emergency Lighting Product Catalogue
IP
20
850 °C
RAL
9003
30 m
-o- LED
EXIT LIGHTS
| Custom Pictogram options available
81
Teknoware Emergency Lighting Product Catalogue
LINESPOT II LOWBAY EN
60598-2-22
-o- LED IP
44
RAL
9003
SURFACE
MOUNTING
DIMENSIONS
120
180
50
5
120
180 180 68 43
65 21
21 65
50
21
82
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
Product code Nominal Max input power Luminous Operation Temperature Electrical Weight
supply voltage flux (lm) mode range installation (kg)
TWS9992WA 220-240 V, 3 VA during boost charge 60 1 h Escap -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWS9992WM 220-240 V, 3 VA during boost charge 60 1 h Escap + M -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge +35°C -o-
ACCESSORIES
Product code Product
EMERGENCY LIGHTS
115
1040
137
52
83
Teknoware Emergency Lighting Product Catalogue
LINESPOT II MIDBAY EN
60598-2-22
-o- LED IP
44
RAL
9003
SURFACE
MOUNTING
Direction of the
light pattern Linespot II Midbay, TWT88/TWS88, is a surface
mounted LED emergency light. It has been
designed especially for illuminating 3 to 10 m high
spaces (TWT8871W/51WK). The High Output
version, TWT8856WK, is suitable for illuminating
4 to 16 m high spaces.
DIMENSIONS
50 120
180
65 21
21 65
50
21
84
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
Product code Nominal Max input power Luminous Operation Temperature Electrical Weight
supply voltage flux (lm) mode range installation (kg)
TWS8892WA 220-240 V, 3 VA during boost charge 65 1 h Escap -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWS8892WM 220-240 V, 3 VA during boost charge 65 1 h Escap + M -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge +35°C -o-
TWT8852WA 220-240 V, 3 VA during boost charge 175 1 h battery 0… 3 x 2,5 mm2 0,7
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWT8853WA 220-240 V, 6 VA during boost charge 175 3 h battery 0… 3 x 2,5 mm2 0,9
50/60 Hz AC 5,5 VA during trickle charge + Aalto +35°C -o-
TWT8852WM 220-240 V, 3 VA during boost charge 175 1 h battery + M 0… 3 x 2,5 mm2 0,7
50/60 Hz AC 2 VA during trickle charge +35°C -o-
TWT8853WM 220-240 V, 6 VA during boost charge 175 3 h battery + M 0… 3 x 2,5 mm2 0,9
50/60 Hz AC 5,5 VA during trickle charge +35°C -o-
ACCESSORIES
Product code Product
EMERGENCY LIGHTS
115
1040
137
52
85
Teknoware Emergency Lighting Product Catalogue
LINESPOT II LOWBAY EN
60598-2-22
-o- LED IP
20
IP
44
RAL
9003
APERTURE
FOR
FOR
RECESS
MOUNTING
MOUNTING
Ø 75 MM
DIMENSIONS
TWT14751WK TWT1471W
290 35 229
34
277 215
50 45 50 45
100 21 21
4,5
4,5
290 229 43
75 48 75
TWT145XWA/M TWS1492WA/M
40 284 175 37
270
50 45 42 50 45
270 21
60 4
25
64 284 175
100 4
100 74
67
75 4 165
220
86
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
TWS1492WA 220-240 V, 3 VA during boost charge 60 1 h Escap -25… 3 x 2,5 mm2 0,5
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWS1492WM 220-240 V, 3 VA during boost charge 60 1 h Escap -25… 3 x 2,5 mm2 0,5
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWT1452WA 220-240 V, 3 VA during boost charge 180 1 h battery 0… 3 x 2,5 mm2 0,4
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWT1453WA 220-240 V, 6 VA during boost charge 180 3 h battery 0… 3 x 2,5 mm2 0,4
50/60 Hz AC 5,5 VA during trickle charge + Aalto +35°C -o-
TWT1452WM 220-240 V, 3 VA during boost charge 180 1 h battery 0… 3 x 2,5 mm2 0,4
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWT1453WM 220-240 V, 6 VA during boost charge 180 3 h battery 0… 3 x 2,5 mm2 0,4
50/60 Hz AC 5,5 VA during trickle charge +M +35°C -o-
*) ACCESSORIES
Product code Product
TMT389 Gasket ring, through which the visible parts of the light will achieve IP44 protection rating
EMERGENCY LIGHTS
87
Teknoware Emergency Lighting Product Catalogue
LINESPOT EN
60598-2-22
-o- LED IP
20
RAL
9003
APERTURE
FOR
FOR
RECESS
MOUNTING
MOUNTING
Ø 75 MM
DIMENSIONS
46
9 55
101
101
45 229 21 21 290
215 290 229 21
45 46 277
277 215
54
55 55
4,5 34 4,5 4,5
34 4,5 35
229
290 229 290
101
101 43 43 101
75 48
75
75
88
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
Product code Nominal Max input power Luminous Operation Temperature Electrical installation Weight
supply voltage flux (lm) mode range (kg)
EMERGENCY LIGHTS
89
Teknoware Emergency Lighting Product Catalogue
ZONESPOT II LOWBAY EN
60598-2-22
-o- LED IP
44
RAL
9003
SURFACE
MOUNTING
DIMENSIONS
180 50 120
5
180 180 120
68 43
65 21
21 65
50
21
90
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
TWS9292WA 220-240 V, 3 VA during boost charge 65 1 h Escap -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWS9292WAC 220-240 V, 3 VA during boost charge 80 1 h Escap -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWS9292WM 220-240 V, 3 VA during boost charge 65 1 h Escap -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWS9292WMC 220-240 V, 3 VA during boost charge 80 1 h Escap -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWT9252WA 220-240 V, 3 VA during boost charge 185 1 h battery 0… 3 x 2,5 mm2 0,7
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWT9253WA 220-240 V, 6 VA during boost charge 185 3 h battery 0… 3 x 2,5 mm2 0,9
50/60 Hz AC 5,5 VA during trickle charge + Aalto +35°C -o-
TWT9252WM 220-240 V, 3 VA during boost charge 185 1 h battery 0… 3 x 2,5 mm2 0,7
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWT9253WM 220-240 V, 6 VA during boost charge 185 3 h battery 0… 3 x 2,5 mm2 0,9
50/60 Hz AC 5,5 VA during trickle charge +M +35°C -o-
1040
137
52
91
Teknoware Emergency Lighting Product Catalogue
ZONESPOT II MIDBAY EN
60598-2-22
-o- LED IP
44
RAL
9003
SURFACE
MOUNTING
Installation video of
Zonespot II is easy and fast to install,
Zonespot II Midbay thanks to a separate mounting base
into which also the supply cables are
connected.
DIMENSIONS
50 120
180
65 21
21 65
50
21
92
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
Product code Nominal Max input power Luminous Operation Temperature Electrical Weight
supply voltage flux (lm) mode range installation (kg)
TWS9392WA 220-240 V, 3 VA during boost charge 60 1 h Escap -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWS9392WAC 220-240 V, 3 VA during boost charge 70 1 h Escap -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWS9392WM 220-240 V, 3 VA during boost charge 60 1 h Escap -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWS9392WMC 220-240 V, 3 VA during boost charge 70 1 h Escap -25… 3 x 2,5 mm2 0,9
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWT9352WA 220-240 V, 3 VA during boost charge 165 1 h battery 0… 3 x 2,5 mm2 0,7
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWT9353WA 220-240 V, 6 VA during boost charge 165 3 h battery 0… 3 x 2,5 mm2 0,9
50/60 Hz AC 5,5 VA during trickle charge + Aalto +35°C -o-
TWT9352WM 220-240 V, 3 VA during boost charge 165 1 h battery 0… 3 x 2,5 mm2 0,7
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWT9353WM 220-240 V, 6 VA during boost charge 165 3 h battery 0… 3 x 2,5 mm2 0,9
50/60 Hz AC 5,5 VA during trickle charge +M +35°C -o-
ACCESSORIES
Product code Product
EMERGENCY LIGHTS
SHOCK PROTECTING COVER SUSPENSION BRACKET
TW77507B TW77504F
115
1040
137
52
93
Teknoware Emergency Lighting Product Catalogue
ZONESPOT II HIGHBAY EN
60598-2-22
-o- LED IP
44
RAL
9003
SURFACE
HIGH MOUNTING
OUTPUT
460 FROM
LUMENS 6 TO 30
METERS
DIMENSIONS
50 120
180
65 21
21 65
50
21
94
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
1040
137
52
EMERGENCY LIGHTS
95
Teknoware Emergency Lighting Product Catalogue
ZONESPOT II LOWBAY EN
60598-2-22
-o- LED IP
20
IP
44
RAL
9003
APERTURE
FOR
FOR
RECESS
MOUNTING
MOUNTING
Ø 75 MM
DIMENSIONS
TWT0451WK TWT0471W
290 35 229
34
277 215
50 45 50 45
100 21 21
4,5 4,5
290
229 43
100
100
| Aperture for mounting Ø 75 mm
75 48
75
TWT045XWA/M TWS0492WA/M
96
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
Product code Nominal Max input power Luminous Operation Temperature Electrical installation Weight
supply voltage flux (lm) mode range (kg)
TWS0492WA 220-240 V, 3 VA during boost charge 65 1 h Escap -25… 3 x 2,5 mm2 1,0
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWS0492WAC 220-240 V, 3 VA during boost charge 80 1 h Escap -25… 3 x 2,5 mm2 1,0
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWS0492WM 220-240 V, 3 VA during boost charge 65 1 h Escap -25… 3 x 2,5 mm2 1,0
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWS0492WMC 220-240 V, 3 VA during boost charge 80 1 h Escap -25… 3 x 2,5 mm2 1,0
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWT0452WA 220-240 V, 3 VA during boost charge 200 1 h battery 0… 3 x 2,5 mm2 0,6
50/60 Hz AC 2 VA during trickle charge + Aalto +35°C -o-
TWT0453WA 220-240 V, 6 VA during boost charge 200 3 h battery 0… 3 x 2,5 mm2 0,8
50/60 Hz AC 5,5 VA during trickle charge + Aalto +35°C -o-
TWT0452WM 220-240 V, 3 VA during boost charge 200 1 h battery 0… 3 x 2,5 mm2 0,6
50/60 Hz AC 2 VA during trickle charge +M +35°C -o-
TWT0453WM 220-240 V, 6 VA during boost charge 200 3 h battery 0… 3 x 2,5 mm2 0,8
50/60 Hz AC 5,5 VA during trickle charge +M +35°C -o-
EMERGENCY LIGHTS
*) ACCESSORIES
Product code Product
TMT389 Gasket ring, through which the visible parts of the luminaire will achieve IP44 protection rating
97
Teknoware Emergency Lighting Product Catalogue
SAFE 29 EN
60598-2-22
-o- IP
65
RAL
9003
WALL AND
SURFACE
MOUNTING
AS STANDARD
RECESS MOUNTING
DIMENSIONS WITH A SEPARATE FRAME
APERTURE FOR RECESS MOUNTING
350 MM X 215 MM
341
189
398
53
94
246
341
270
21
32
189
80
70
24
98
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
TWT2971W 24 - 230 V 24 V= 7,3 VA /4,7 W LED 190 CBS -30… 24 V= 2 x 2,5 mm2 1,2
50/60 Hz 230 V=15,4 VA /5,3 W +50°C 230 V=3 x 2,5 mm2
AC,DC -o-
TWT2951WK 220-240 V, 8,3 VA / 4,6 W LED 190 CBS/ -30… 3 x 2,5 mm2 1,2
50/60 Hz C + IC +50°C -o-
AC,DC
Product code Nominal Max input Light source Luminous Operation Temperature Electrical Weight
supply voltage power flux (lm) mode range installation (kg)
TWT2953W 220-240 V, 19,5 VA LED 155 3 h battery 0… +35°C 3 x 2,5 mm2 1,5
*) 50/60 Hz AC -o-
| Light is for open areas
| Light is for escape routes
| *) non-maintained
5,5
47 390
317
390
180
208
60
99
Teknoware Emergency Lighting Product Catalogue
SAFE 82
Protection
EN -o-
Class II IP RAL
60598-2-22 44 9003
CEILING EASY TO
AND WALL INSTALL
MOUNTING THANKS TO
AS A SEPARATE
STANDARD MOUNTING
BASE
DIMENSIONS
350 4
4
160
125
60
125
93 86
93
350
100
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
EMERGENCY LIGHTS
101
Teknoware Emergency Lighting Product Catalogue
SAFE 6 EN
60598-2-22
-o- LED IP
44
RAL
9003
CEILING,
WALL
AND FLAG
MOUNTING
AS
STANDARD
63 281
14
84
84
96
267
18 21 18 23
124
WALL MOUNTING
79
17
58
96
102
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
TWT0671W 24-230 V, 24 V=9 VA /8 W 345 CBS -30… 24 V=2 x 2,5 mm2 1,0
50/60 Hz AC,DC 230 V=15 VA /6,5 W (315 with lens set) +50°C 230 V=3 x 2,5 mm2
-o-
Product code Nominal Max input power Luminous flux (lm) Operation Temperature Electrical Weight
supply voltage mode range installation (kg)
ACCESSORIES
Product code Product
268
66 Max.
1000mm
106
57
43
103
Teknoware Emergency Lighting Product Catalogue
TRISPOT TWT75 & TWT76 EN
60598-2-22
-o- LED IP
20
EMERGENCY LIGHT FOR HIGH MOUNTING EMERGENCY LIGHT FOR LOW AND OPEN AREAS APERTURE
FOR
FOR
TWT75XX TWT76XX RECESS
MOUNTING
MOUNTING
Ø 60 MM
DIMENSIONS
290
70 60 48
70
290
55 277
57
58 21
58
4,5 35
| Length of the cable 450 mm
55
55
57 57
2 2
70 70
104
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
Product code Nominal Max input Luminous Operation mode Temperature Electrical installation Weight
supply voltage power flux (lm) range (kg)
EMERGENCY LIGHTS
105
Teknoware Emergency Lighting Product Catalogue
SLIMSPOT EN
60598-2-22
-o- LED IP
20
RAL
9003
FOR APERTURE
RECESS FOR
MOUNTING MOUNTING
Ø 75 MM
229
40 290
215 40 277
42 42
21 34 21
4,5
103 4,5 35
229
290
103 43 103
48
75 75
70 TWS9792WX TWS9792WX
290 190
42 277 160
40 42
103 44
2 103 4,5 4,5 40
2 42
44 103
48
75
103
106
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
Product code Nominal Max input power Luminous Operation Temperature Electrical installation Weight
supply voltage flux (lm) mode range (kg)
EMERGENCY LIGHTS
107
Teknoware Emergency Lighting Product Catalogue
MINI LINESPOT EN
60598-2-22
-o- LED IP
20
RAL
9003
FOR APERTURE
RECESS FOR SPOT
MOUNTING Ø 30 MM
29
DIMENSIONS
30
32
52
38
38
20
229 290
43 48
290
229 277
215 32
32
52 21 52 21
4,5 34 4,5
108
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
Product code Supply Max input power Luminous Operation mode Temperature Electrical installation Weight
voltage flux (lm) range (kg)
EMERGENCY LIGHTS
109
Teknoware Emergency Lighting Product Catalogue
SAFE 95 EN
60598-2-22
EN
1838
-o- LED IP
67
FOR
SURFACE
MOUNTING
DIMENSIONS
304
126 7
126 120 80
126
280
304
126
110
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
EMERGENCY LIGHTS
111
Teknoware Emergency Lighting Product Catalogue
HANDRAIL EMERGENCY LIGHT EN
60598-2-22
-o- LED IP
65
RAL
9003
RECESSED
TO A
Ø 60,3MM
PIPE-
RAILING
MOUNTING
DIMENSIONS
112
Teknoware Emergency Lighting Product Catalogue
IP LED
20
RAL
9003
850 °C
-o-
TWT9111 230 V 3,3 VA / 120 Master monitoring -25…+70°C 2 x 2,5 mm2 0,35
AC/DC 3W CBU / C (+50°C for countinuous operation) -o-
TWT9112 230 V 3,3 VA / 120 Slave monitoring -25…+70°C 2 x 2,5 mm2 0,35
AC/DC 3W CBU (+50°C for countinuous operation) -o-
TWT9141 230 V 7,7 VA / 360 Master monitoring -25…+70°C 2 x 2,5 mm2 0,35
AC/DC 7,1 W CBU / C (+50°C for countinuous operation) -o-
TWT9142 230 V 7,7 VA / 360 Slave monitoring -25…+70°C 2 x 2,5 mm2 0,35
AC/DC 7,1 W CBU (+50°C for countinuous operation) -o-
Example of connection of one addressable MASTER, and two SLAVE lights (all the lights have the same address).
Master light can also be used alone.
L
N
For non-addressable lights (TWT9110 & TWT9140) a normal through-wiring can be used.
h
26°
R2
R1
113
Teknoware Emergency Lighting Product Catalogue
SHOCK PROTECTING COVERS
| Shock protecting covers are used in e.g. sports halls, gyms and stadiums, to protect the luminaires
X Y Z A
114
Teknoware Emergency Lighting Product Catalogue
FREQUENTLY ASKED QUESTIONS
WHAT DO THE FOLLOWING SYMBOLS AND ABBREVIATIONS MEAN IN TEKNOWARE PRODUCT CATALOGUE?
=The product conforms with the essential EN =Verified photometric data on the light available according to
requirements of the applicable EC directives. 60598-2-22 standard EN60598-2-22
RAL RAL
=Colour of the body =Colour of the light body (RAL 9006 =grey)
9003 9006
(RAL 9003 =white)
=Viewing distance
30 m
Class I The protection is provided by a combination of basic insulation and the use of electrical earth.
Class II Double-insulated electrical products which comprise both basic insulation and supplementary insulation
Class III Lights are designed to be supplied from a special safety isolating transformer whose output is known as Safety Extra-Low Voltage or SELV
IP
IP-classification xx
Degree of protection against solid foreign objects (1st number) Protection against
0 Non-protected
5 Dust-protected
6 Dust-tight
0 Non-protected
115
Teknoware Emergency Lighting Product Catalogue
CONTENTS
Product code Page Product code Page Product code Page Product code Page
116
Teknoware Emergency Lighting Product Catalogue
Product code Page Product code Page Product code Page
117
Teknoware Emergency Lighting Product Catalogue
CERTIFICATIONS AND APPROVALS
Certified by SGS FI
118
Teknoware Emergency Lighting Product Catalogue
CONTACT INFORMATION
www.teknoware.ae
119
Teknoware Emergency Lighting Product Catalogue
TEKNOWARE 4
CENTRAL MONITORING 37
CONTENTS 116
ISSUE TWME 1003 MIDDLE EAST EDITION
Teknoware Middle East FZCO Teknoware Oy
LIU H12 Ilmarisentie 8
Dubai Airport Freezone FI-15200 LAHTI
Dubai FINLAND
UAE
Tel. +358 3 883 020
Tel: +9714 2993622 Fax +358 3 883 0260
Fax: +9714 2993623
info@teknoware.ae emexit@teknoware.com
www.teknoware.ae www.teknoware.com