Professional Documents
Culture Documents
Agent:
INTRODUCTION 3
AHP03 SERIES
Single Drive Single Acting
5
AHP06 SERIES
Petro Single Drive Single Acting
7
AHP06 SERIES
9
i cal Double Drive Single Acting
Ch e m
AHP06 SERIES
11
ce Triple Drive Single Acting
A erospa
AHP06 SERIES 13
Single Drive Double Acting
t ti ng
a t e r je t Cu
W AHP06 SERIES
Double Drive Double Acting
15
AHP06 SERIES
Long Stroke Single Drive Double Acting
17
AHP10 SERIES
Single Drive Double Acting
19
HYDR-STAR passed the ISO9001 quality management system certification and our
products passes SIL and EAC certification. Our products are recognized by clients and
customers in Middle East, European Union, Russia, China and other countries.
After years of hard work, HYDR-STAR has become an industry leader and has
established list of regular customers from around the globe. Our products are being used
in oil&gas, petrochemical, energy, mining, aerospace, military, automotive, firefighting
and conventional hydraulic machinery Industries.
1 2
The series and its functions
HYDR-STAR pumps offer the right solution for every application. They are suitable for different or
Air Driven Liquid Pumps stepped flow rates as well as for different maximum allowable operating pressures.HYDR-STAR
pumps with two or three air drive sections reach the same final pressure as a HYDR-STAR pump
Features with one air drive section with 1/2 or 1/3 of the air drive. Double-acting pumps increase the pump
★ Up to 100,000 psi (7000 bar) capability. ★ Robust, reliable, compact and easy to capacity by around 50% in comparison to single-acting pumps and reduce the pulsation equally.
★ Infinitely variable cycling speed. maintain proven design. The following model variants are available depending on the series:
★ Stall feature at pre-determined pressure ★ Unbalanced cycling spool provides immediate
to hold that pressure without consuming power . response to pressure changes.
★ Easily automated, with many modification ★ Also available in standard, Configuration
and control options available. required by customer.
★ Suitable for most liquids and liquefied gases. ★ No need for air-line lubrication, which saves
★ Can be manufactured to meet CE, ATEX and NACE. costs and prevents contamination.
Easy handling
1. Initial operation 2. Build up pressure
The pump is prepared for operation manually: The pump technology executes all the steps for pressure
★ Connect supply lines (compressed air, suction and build-up automatically:
pressure lines). ★ Automatic cycling of 4/2-way valve (spoolcycling valve)
★ Set air drive pressure. by means of air pulses from the pilot valve (2/2-way valve)
★ Open compressed air supply slowly so that the high- ★ Suction of medium.
pressure pump starts up . ★ Optimum cycling conditions thanks to large cross- Angular Pumps
sections .
3. Achieve and hold pressure
The pump controls the processes of reaching and
holding pressure.
★ Pump automatically stops operating when the
operating pressure is reached due to equilibrium of
forces Pumps With Handle
★ Pressure is held.
★ Pressure holding phase with no energy consumption Double Air Drive,Single Acting
or heat generation .
★ Pump restarted automatically if operating pressure
drops .
Applications
★ Pressure testing
★ Jacking and Lifting.
★ Valve actuator control
★ Hydraulic cylinder actuation
★ Roller tensioning
★ Precision lubrication and spraying Single Air Drive,Single Acting Triple Air Drive,Single Acting
Selection
The pump model is selected according to the use requirements. Such as output pressure, output flow, medium and
temperature, available air or gas drive pressure and flow. This guide will help you to pre-select the pump ideally suited
for your application. If you have specific questions, Please contact us. We urge you to provide us with details of the Single Air Drive,Double Acting Double Air Drive,Double Acting
duties you require from the pump, available air/gas drive pressure, and pressure/flow requirements, and we will
recommend a model and any corresponding accessories.
3 4
Perfomance Curves
★ Pressures to 25,000 psi(1723 bar). 0 200 400 600 0 200 400 600 800 1000
★ All Hydraulic fluids, water(plain or DI),
solvents, mild chemicals, liquefied gases. AHP03-1S-12 AHP03-1S-21
4.92 3.28
Pump Model Code Max.Out Press. Actual Ratio Dis. /Cycle Max.Flow Inlet Port Outlet Port 3.28 1.64
0.28S CU.M/MIN
AHP03-1S-5 625psi 5.6:1 13.6ml 8.30l/min 1"FNPT 1/2"FNPT 100PSI 0.28S CU.M/MIN 0.42S CU.M/MIN
0.14S CU.M/MIN
AHP03-1S-7 900psi 7.8:1 9.8ml 6.0l/min 3/4"FNPT 1/2"FNPT 1.64 4.09
0.14S CU.M/MIN
AHP03-1S-12 1500psi 14:1 5.9ml 3.83l/min 3/4"FNPT 1/2"FNPT 100PSI
75PSI
AHP03-1S-21 2600psi 25:1 3.3ml 2.13l/min 3/8"FNPT 1/4"FNPT 75PSI
LIQUID FLOW-LTRES/MIN.
AHP03-1S-36 4500psi 41:1 2.0ml 1.28l/min 3/8"FNPT 1/4"FNPT
AHP03-1S-71 8800psi 82:1 1.0ml 0.64l/min 3/8"FNPT 1/4"FNPT
AHP03-1S-36 AHP03-1S-71
AHP03-1S-110 13500psi 126:1 0.6ml 0.42l/min 3/8"FNPT 1/4"FNPT 1.97 0.983
Dimensions 0.655
75PSI
0.328
0.14S CU.M/MIN 75PSI 0.28S CU.M/MIN
0.14S CU.M/MIN 100PSI 100PSI
0 1000 2000 3000 4000 5000 0 2000 4000 6000 8000 10000
E
AHP03-1S-110 AHP03-1S-188
0.655 0.329
D 125PSI
125PSI
Size A 3.82in.(97mm)
C
Size B 10in.(254mm) 0.28S CU.M/MIN 0.57S CU.M/MIN
0.42S CU.M/MIN
Size C 1.65in.(42mm) 0.328 0.164 0.42S CU.M/MIN
Size D 4.13in.(105mm) 0.14S CU.M/MIN 100PSI
0.14S CU.M/MIN 0.28S CU.M/MIN
Size E 4.8in.(122mm)
75PSI 100PSI
Size H 5.59in.(142mm) 75PSI
0.15
0.28S CU.M/MIN
A 0.10 0.57S CU.M/MIN
0.14S CU.M/MIN 125PSI Flow vs Pressure
B 0.05
100PSI Air consumption
EXPLAIN 75PSI
1. All model code listed are standard. 0 5000 10000 15000 20000 25000
For pumps with handle add “-H” after the model codes.
For Pumps with relief valve add“-R” after the model codes.
For pumps with Viton seals add “-V” after the model codes.
OUTLET PRESSURE(PSI)
For pumps with Pressure switch valve add “-P” after the model codes.
For cold area ser vice add “-C” after the model codes.
2. Other sizes, materials and types are available upon request. For special requirements, please contact us.
5 6
Perfomance Curves
AHP06-1S-10
AHP06 Series 20.5
150PSI
13.1
AHP06-1S-15
150PSI
Single Drive Single Acting 16.4
9.83
1.42S CU.M/MIN
Features 12.3
2.12S CU.M/MIN 2.12S CU.M/MIN
6.56
★ Choice of 10 ratios. 50PSI
8.19
★ Flows to 19.9 l/min. 0.71S CU.M/MIN 75PSI 1.42S CU.M/MIN
0.71S CU.M/MIN 75PSI
100PSI
★ Choice of wetted materials. 3.28
4.1
★ Output pressures to 60,000 psi (4137 bar). 125PSI
50PSI 100PSI 125PSI
★ Drive pressure 3 to 150 psi (0.2 to 10.3 bar).
0 400 800 1200 1600 0 500 1000 1500 2000 2500
solvents, mild chemicals, liquefied gases.
AHP06-1S-25 AHP06-1S-35
5.74
Performance and Specification 8.19
150PSI
150PSI
Pump Model Code Max.Out Press. Actual Ratio Dis. /Cycle Max.Flow Inlet Port Outlet Port 4.92
6.56
AHP06-1S-10 1600psi 14:1 66.4ml 19.9l/min 1"FNPT 1/2"FNPT 125PSI 4.1
2.12S CU.M/MIN
AHP06-1S-15 2400psi 18:1 44.3ml 13.3l/min 1"FNPT 1/2"FNPT 4.92 3.28
2.12S CU.M/MIN
AHP06-1S-25 4000psi 30:1 26.6ml 8l/min 1/2"FNPT 1/2"FNPT
3.28 2.46 1.42S CU.M/MIN
AHP06-1S-35 5700psi 45:1 19.0ml 5.7l/min 1/2"FNPT 1/2"FNPT 75PSI 1.42S CU.M/MIN 0.71S CU.M/MIN
0.71S CU.M/MIN 100PSI 1.64
AHP06-1S-60 10000psi 72:1 11.0ml 3.3l/min 1/2"FNPT 1/2"FNPT 75PSI
1.64
1/2"FNPT 1/2"FNPT 0.82
AHP06-1S-100 15000psi 120:1 6.7ml 2 l/min 50PSI 50PSI 100PSI
125PSI
LIQUID FLOW-LTRES/MIN.
AHP06-1S-150 22500psi 180:1 4.5ml 1.3l/min 1/2"FNPT 1/4"HF
0 1000 2000 3000 4000 0 1000 2000 3000 4000 5000 6000
AHP06-1S-225 33750psi 270:1 3.0ml 0.7l/min 1/2"FNPT 1/4"HF
AHP06-1S-60 AHP06-1S-100
3.28 2.05
AHP06-1S-300 45000psi 360:1 2.3ml 0.5l/min 1/2"FNPT 1/4"HF
150PSI
AHP06-1S-450 60000psi 545:1 1.5ml 0.3l/min 1/2"FNPT 1/4"HF
1.64
HF means female high pressure connection. 2.46
2.12S CU.M/MIN 150PSI
Dimensions 1.23
1.42S CU.M/MIN 2.12S CU.M/MIN
in.(mm) 1.64
50PSI
9.1(231) 3(76.2) 0.81
0.71S CU.M/MIN 75PSI 1.42S CU.M/MIN 0.71S CU.M/MIN
7.64(194) 100PSI
0.82
0.41
100PSI 125PSI 50PSI 75PSI 125PSI
AHP06-1S-150
11.15(283.3)
AHP06-1S-225
1.31 0.819
150PSI 150PSI
0.983 0.656
2.12S CU.M/MIN
125PSI 1.42S CU.M/MIN
1.42S CU.M/MIN 0.492
2.12S CU.M/MIN
0.656
IN OUT 0.328
0.71S CU.M/MIN 0.71S CU.M/MIN 75PSI
0.329
0.164
6.81(173) 50PSI 75PSI 100PSI 50PSI 125PSI
10.35(263) 0 4000 8000 12000 16000 20000 0 10000 20000 30000 37000
AHP06-1S-300
Air IN port is 3/4 female NPT for standard pumps 0.656
EXPLAIN 150PSI
For Quick repair pumps add “-Q” after the model codes. 125PSI Air consumption
0.328
For pumps with relief valve add “-R” after the model codes.
1.42S CU.M/MIN
For pumps with Viton seals add “-V” after the model codes. 0.71S CU.M/MIN 75PSI
For pumps with Pressure switch valve add “-P” after the model codes. 0.164
For cold area ser vice add “-C” after the model codes. 100PSI
50PSI
For liquid CO2 add “-C2” after the model codes. 0 10000 20000 30000 40000 50000
2. Other sizes, materials and types are available upon request. For special requirements, please contact us.
OUTLET PRESSURE(PSI)
7 8
Perfomance Curves
AHP06-2S-20 AHP06-2S-30
12
AHP06 Series 20
150PSI
10
Double Drive Single Acting 16
8
150PSI
2.12S CU.M/MIN
12
Features 1.42S CU.M/MIN 2.12S CU.M/MIN
6
★ Choice of 9 ratios. 8 1.42S CU.M/MIN
★ Flows to 19.9 l/min. 0.71S CU.M/MIN
4
0.71S CU.M/MIN
★ Choice of wetted materials. 4
2
★ Output pressures to 75,000 psi (5171 bar). 50PSI 75PSI 100PSI 125PSI 50PSI 75PSI 100PSI 125PSI
★ Drive pressure 3 to 150 psi (0.2 to 10.3 bar). 0 500 1000 1500 2000 2500 3000 3200 0 1000 2000 3000 4000 4800
Pump Model Code Max.Out Press. Actual Ratio Dis. /Cycle Max.Flow Inlet Port Outlet Port
150PSI 4.1
AHP06-2S-20 3200psi 27:1 66.4ml 19.9l/min 1"FNPT 1/2"FNPT 150PSI
4.92
AHP06-2S-30 4800psi 35:1 44.3ml 13.3l/min 1"FNPT 1/2"FNPT 3.28
2.12S CU.M/MIN
2.12S CU.M/MIN 1.42S CU.M/MIN
AHP06-2S-50 5000psi 60:1 26.6ml 8 l/min 1/2"FNPT 1/2"FNPT 2.46
3.28 1.42S CU.M/MIN
AHP06-2S-70 11000psi 90:1 19.0ml 5.7l/min 1/2"FNPT 1/2"FNPT
1.64 0.71S CU.M/MIN
AHP06-2S-120 19000psi 144:1 11.0ml 3.3l/min 1/2"FNPT 1/2"FNPT
1.64 0.71S CU.M/MIN 125PSI
LIQUID FLOW-LTRES/MIN.
AHP06-2S-200 33000psi 240:1 6.7ml 1.5l/min 1/2"FNPT 1/4"HF 0.82
50PSI 75PSI 100PSI 125PSI 50PSI 75PSI 100PSI
AHP06-2S-300 50000psi 360:1 4.5ml 1 l/min 1/2"FNPT 1/4"HF
0 1500 3000 4500 6000 0 2000 4000 6000 8000 10000 11000
AHP06-2S-450 70000psi 540:1 3.0ml 0.7l/min 1/2"FNPT 1/4"SF
AHP06-2S-120 AHP06-2S-200
AHP06-2S-600 75000psi 720:1 2.3ml 0.5l/min 1/2"FNPT 1/4"SF 3.28 1.64
HF means female high pressure connection. 150PSI 150PSI
SF means female super high pressure connection.
1.31
Dimensions 9.1(231) 3(76.2) 2.46
in.(mm) 0.983
7.64(194)
2.12S CU.M/MIN
1.64 1.42S CU.M/MIN 2.12S CU.M/MIN 1.42S CU.M/MIN
0.656
125PSI
0 4000 8000 12000 16000 20000 0 5000 10000 15000 20000 25000 30000
15.4(391.2)
AHP06-2S-300 AHP06-2S-450
0.983 0.657
150PSI
0.819
150PSI 0.492
0.656
1.42S CU.M/MIN 2.12S CU.M/MIN
0.492 2.12S CU.M/MIN 0.328
For pumps with Viton seals add “-V” after the model codes. 0.164 1.42S CU.M/MIN
0.71S CU.M/MIN
For pumps with Pressure switch valve add “-P” after the model codes.
0.082
For cold area ser vice add “-C” after the model codes. 50PSI 75PSI
100PSI
For liquid CO2 add “-C2” after the model codes. 0 10000 20000 30000 40000 50000 60000 70000
2. Other sizes, materials and types are available upon request. For special requirements, please contact us.
OUTLET PRESSURE(PSI)
9 10
Perfomance Curves
LIQUID FLOW-LTRES/MIN.
AHP06-3S-675 70000psi 800:1 3.0ml 0.41l/min 1/2"NPT 1/4"SF 0 10000 20000 30000 40000 50000 60000 70000 0 10000 20000 30000 40000 50000 60000 70000 75000
AHP06-3S-900 75000psi 100:1 2.3ml 0.33l/min 1/2"NPT 1/4"SF
AHP06-3S-1350 100000psi AHP06-3S-1350
1500:1 1.5ml 0.20l/min 1/2"NPT 1/4"SF 0.197
SF means female super high pressure connection .
Dimensions 0.147
in.(mm) 3(76.2)
9.1(231)
7.64(194)
100PSI
0.098
0.049
75PSI Flow vs Pressure
50PSI
Air consumption
15.83(402)
OUTLET PRESSURE(PSI)
IN OUT
6.81(173)
10.35(263)
EXPLAIN
1. All model code listed are standard.
For angle pumps add “A” after the model codes.
For Quick repair pumps add “-Q” after the model codes.
For pumps with relief valve add “-R” after the model codes.
For pumps with Viton seals add “-V” after the model codes.
For pumps with Pressure switch valve add “-P” after the model codes.
For cold area ser vice add “-C” after the model codes.
For liquid CO2 add “-C2” after the model codes.
2. Other sizes, materials and types are available upon request. For special requirements, please contact us.
11 12
Perfomance Curves
AHP06 Series 41
AHP06-1D-10
26.22
AHP06-1D-15
22.95
Single Drive Double Acting 32.8
19.67
Features 16.4
★ Choice of 7 ratios. 24.6
3.54S CU.M/MIN
3.54S CU.M/MIN
★ Flows to 29.9 l/min. 13.1
2.83S CU.M/MIN
1.42S CU.M/MIN 2.83S CU.M/MIN 1.42S CU.M/MIN
★ Choice of wetted materials. 18.4
9.83
2.12S CU.M/MIN 2.12S CU.M/MIN
★ Output pressures to 20,000 psi (1379 bar).
6.56
★ Drive pressure 3 to 150 psi (0.2 to 10.3 bar). 8.19 0.71S CU.M/MIN
0.71S CU.M/MIN 150PSI
50PSI 3.28
Performance and Specification 75PSI
100PSI
125PSI 150PSI 50PSI 75PSI 100PSI 125PSI
Pump Model Code Max.Out Press. Actual Ratio Dis. /Cycle Max.Flow Inlet Port Outlet Port 0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 500 1000 1500 2000 2500 3000
LIQUID FLOW-LTRES/MIN.
9.84
AHP06-1D-35 5700psi 45:1 38ml 8.6l/min 1/2"FNPT 1/2"FNPT 13.1 9.02
11.47 8.2
AHP06-1D-60 9800psi 72:1 22ml 4.9l/min 1/2"FNPT 1/2"FNPT
7.38
9.83
AHP06-1D-100 16500psi 120:1 13.4ml 3.0l/min 1/2"FNPT 1/2"FNPT 3.54S CU.M/MIN 6.56
3.54S CU.M/MIN
8.19 5.74
AHP06-1D-150 20000psi 180:1 9ml 2.0l/min 1/2"FNPT 1/4"HF 2.83S CU.M/MIN 2.83S CU.M/MIN
4.92 0.71S CU.M/MIN
6.56
HF means female high pressure connection. 0.71S CU.M/MIN 2.12S CU.M/MIN 4.1 2.12S CU.M/MIN
4.92 3.28
Dimensions 3.28
1.42S CU.M/MIN
2.46
1.42S CU.M/MIN
LIQUID FLOW-LTRES/MIN.
in.(mm) 75PSI 150PSI 1.64
9.1(231) Bracket Hole 3(76.2) 1.64 50PSI 75PSI 150PSI
50PSI 100PSI 125PSI 0.82
7.64(194) 100PSI 125PSI
0 500 1000 1500 2000 2500 3000 3500 4000 4500 0 1000 2000 3000 4000 5000 6000 7000
AHP06-1D-60 AHP06-1D-100
6.56 4.26
3.94
5.74 3.61
4.92 3.28
2.95
4.1
15.68(398.3)
2.62
3.54S CU.M/MIN 3.54S CU.M/MIN
2.29
3.28
7.14(181.5)
IN OUT
AHP06-1D-150
2.62
2.29
6.81(173)
1.97
10.35(263)
1.64
3.54S CU.M/MIN
Air IN port is 3/4 female NPT for standard pumps
1.312
1.42S CU.M/MIN 2.83S CU.M/MIN
EXPLAIN
0.984
1. All model code listed are standard. 2.12S CU.M/MIN
Flow vs Pressure
For angle pumps add “A” after the model codes. 0.656
0.71S CU.M/MIN 150PSI
For Quick repair pumps add “-Q” after the model codes. 50PSI Air consumption
0.328
For pumps with relief valve add “-R” after the model codes. 75PSI 100PSI 125PSI
For pumps with Viton seals add “-V” after the model codes. 0 5000 10000 15000 20000 25000
For pumps with Pressure switch valve add “-P” after the model codes.
OUTLET PRESSURE(PSI)
For cold area ser vice add “-C” after the model codes.
For liquid CO2 add “-C2” after the model codes.
2. Other sizes, materials and types are available upon request. For special requirements, please contact us.
13 14
Perfomance Curves
Features 8.32
2.12S CU.M/MIN
5.24
LIQUID FLOW-LTRES/MIN.
Pump Model Code Max.Out Press. Actual Ratio Dis. /Cycle Max.Flow Inlet Port Outlet Port 0 1500 3000 4500 6000 7500 10000 0 3000 6000 9000 12000 15000 18000
AHP06-2D-70 11000psi 90:1 38ml 8.6l/min 1/2"FNPT 1/2"FNPT
AHP06-2D-120 19000psi 144:1 22ml 4.9l/min 1/2"FNPT 1/2"FNPT AHP06-2D-200 AHP06-2D-300
3.93
AHP06-2D-200 33000psi 240:1 13.4ml 3.0l/min 1/2"FNPT 1/4"HF
AHP06-2D-300 50000psi 360:1 9ml 2.0l/min 1/2"FNPT 1/4"HF
3.28 2.62
HF means female high pressure connection. 150PSI
150PSI
Dimensions 9.1(231)
2.62 2.1
in.(mm) Bracket Hole 3(76.2) 2.12S CU.M/MIN
2.12S CU.M/MIN
7.64(194) 1.57
1.97
1.7S CU.M/MIN
1.7S CU.M/MIN
1.31 1.05
95PSI 95PSI
0.42S CU.M/MIN 0.85S CU.M/MIN 0.85S CU.M/MIN
0.42S CU.M/MIN
0.66 0.52
50PSI 75PSI 50PSI 75PSI
0 5500 11000 16500 22000 27500 33000 0 7500 15000 22500 30000 37500 45000
OUTLET PRESSURE(PSI)
19.24(488.7)
Flow vs Pressure
Air consumption
11.37(288.8)
IN OUT
6.81(173)
Air IN port is 3/4 female NPT for standard pumps 10.35(263)
EXPLAIN
1. All model code listed are standard.
For angle pumps add “A” after the model codes.
For Quick repair pumps add “-Q” after the model codes.
For pumps with relief valve add “-R” after the model codes.
For pumps with Viton seals add “-V” after the model codes.
For pumps with Pressure switch valve add “-P” after the model codes.
For cold area ser vice add “-C” after the model codes.
For liquid CO2 add “-C2” after the model codes.
2. Other sizes, materials and types are available upon request. For special requirements, please contact us.
15 16
Perfomance Curves
LIQUID FLOW-LTRES/MIN.
100PSI
AHP06-1D-12L 1850psi 14:1 260ml 82.1 l/min 1-1/4"FNPT 3/4"FNPT 40PSI 60PSI 80PSI 40PSI 60PSI 80PSI
AHP06-1D-35L 4375psi 40:1 98ml 31 l/min 1-1/4"FNPT 1/2"FNPT 0 400 800 1200 1600 0 1000 2000 3000 4000 5000
AHP06-1D-60L 7500psi 69:1 57ml 18.1 l/min 1-1/4"FNPT 1/2"FNPT
AHP06-1D-100L 10000psi 120:1 32ml 10.7 l/min 1-1/4"FNPT 1/2"FNPT AHP06-1D-60L AHP06-1D-100L
22.1 13.11
Dimensions
in.(mm) 19.7 11.48
6.81(173)
8.65(219.7)
9.84
Bracket Hole3(76.2) 16.39
6.73(171)
125PSI
8.2
125PSI
13.11
6.56
2.83S CU.M/MIN
1.42S CU.M/MIN 3.28
1.42S CU.M/MIN
3.28
1.64
20.26(514.6)
40PSI 60PSI
40PSI 60PSI 80PSI 80PSI
100PSI
100PSI
0 2000 4000 6000 8000 0 4000 8000 12000
OUTLET PRESSURE(PSI)
Flow vs Pressure
Air consumption
9.95(252.8)
17 18
Perfomance Curves
AHP10 Series 45
AHP10-1D-30
AHP10-1D-60
Single Drive Double Acting
36 20
Features
★ Choice of 5 ratios.
★ Flows to 45.5 l/min. 27 15
★ Choice of wetted materials.
★ Can be quickly repaired.
★ Output pressures to 325,00 psi (2241 bar). 18 10
★ Drive pressure 10 to 125 psi (0.7 to 8.6 bar).
LIQUID FLOW-LTRES/MIN.
★ All hydraulic fluids, water (plain or DI),solvents
liquefied gases. 9 5
90PSI
Performance and Specification 60PSI 90PSI 120PSI
60PSI 120PSI
Pump Model Code Max.Out Press. Actual Ratio Dis. /Cycle Max.Flow Inlet Port Outlet Port
AHP10-1D-30 0 750 1500 2250 3000 3750 0 1000 2000 3000 4000 5000 6000 7000 8000
3750psi 34:1 350ml 45.5 l/min 3/4"FNPT 1/2"FNPT
AHP10-1D-60 7500psi 67:1 180ml 23.4 l/min 3/4"FNPT 1/2"FNPT
AHP10-1D-120 15000psi 125:1 98ml 12.7 l/min 3/4"FNPT 9/16"HF
AHP10-1D-180 22500psi 204:1 60.5ml 7.9 l/min 3/4"FNPT 9/16"HF
AHP10-1D-120 AHP10-1D-180
12 8
AHP10-1D-260 32500psi 304:1 40.5ml 5.3 l/min 3/4"FNPT 9/16"HF
HF means female high pressure connection.
10
Dimensions 6
in.(mm)
8
6 4
4
13(330.2)
2
60PSI 90PSI 120PSI
60PSI 90PSI 120PSI
0 3000 6000 9000 10000 15000 0 4000 8000 12000 16000 20000
13.9(354)x8.7(220)
11(280) OUTLET PRESSURE(PSI)
33(840)
EXPLAIN
1. All model code listed are standard.
For pumps with relief valve add “-R” after the model codes.
For pumps with Viton seals add “-V” after the model codes.
For pumps with Pressure switch valve add “-P” after the model codes.
For cold area ser vice add “-C” after the model codes.
For liquid CO 2 add “-C2” after the model codes.
2. Other sizes,materials and types are available upon request. For special requirements, please contact us.
19 20
Perfomance Curves
LIQUID FLOW-LTRES/MIN.
15 7.5
★ Can be quickly repaired.
★ Output pressures to 650,00 psi (4482 bar).
★ Drive pressure 10 to 125 psi (0.7 to 8.6 bar).
★ All hydraulic fluids, water (plain or DI),solvents 10 5
liquefied gases.
Dimensions 6
in.(mm)
5 3
13(330.2) 4
2
3
2
1
1
23.4(594)x8.7(220) 60PSI 90PSI 120PSI
60PSI 120PSI
11(280) 90PSI
0 6000 12000 18000 24000 30000 0 9000 18000 27000 36000 45000
42.5(1080)
OUTLET PRESSURE(PSI)
EXPLAIN
1. All model code listed are standard.
For pumps with relief valve add “-R” after the model codes.
For pumps with Viton seals add “-V” after the model codes.
For pumps with Pressure switch valve add “-P” after the model codes.
For cold area ser vice add “-C” after the model codes.
For liquid CO 2 add “-C2” after the model codes.
2. Other sizes,materials and types are available upon request. For special requirements, please contact us.