You are on page 1of 2

A 8

A 8
5 3 5
9 2 9 VML 3
DLV A3 VM L
J DLV A3
J VRFP 2
OUT IN VRF P IN
4
4
VMD
6 1 VMP/S
VMD VMP/ S
1

VSMA 10
7 MAN
7
10 ML
6

Valve 1” ¼ , 1” ½ Valve 2”

Y-
L
E

0,3÷0,5s
D

DN UP

chg  0,02s
Y  1,5s
G

H
I
A
VMD
VML

VML

VMP
M

ON OFF

[G]
3010/S [G]
VS MA
5 VSMA (J =1:1)
VRFP VMD
9 ML
4 7
VML [F]
[A] [G]
VS MA
S [C] ML
3 [F] 7
[ B] K
J
VS 1 VMP/S
(Y-/S CC)
ML
R/S2
1 VRF [H] [L] [F]
8 VRP
VB [E] VC 3006/B
[F] R/S1
VR 2 [H] [L]
[F]

VR2 PAM [H]


VS10
PAM
[E] REMOT E
DAL
[F]
VR a 10
VR1 6
Ma ISP
DLV
M
Pmax P min OLD
MAN

VALVE 3010/S + DLV A3 TABLE : 04.008.EN VER.: D


HYDRAULIC CIRCUIT DATE : 02.04.2014 1/2
ABBREVIATIONS FOR ALL THE GMV HYDRAULIC SCHEMES
1 Adjustment screw : safety valve (pressure P
VRP pilot spool
relief)
2 Adjustment screw : levelling speed PAM Hand pump
3 Adjustment screw : deceleration (upward / Pmax
Maximum pressure limit switch
downward)
4 Adjustment screw : acceleration (upward) Pmin minimum pressure limit switch
5 Shut-off valve / Screw for rupture valve test PT Pressure transducer
6 Shut-off valve for pressure gauge exclusion R/S Ball valve (1) / Silencer (2)
7 Adjustment screw : ram pressure (only 2:1 RDY Ready - Ready signal (card output to control
acting jacks) panel)
8 Adjustment screw : high speed RIT Delay
9 Adjustment screw : downward speed RO
Oil heating resistance
compensation
10 Adjustment screw : safety valve (PAM) RT Motor thermistors
3010, 3010EN RUN Run - Start signal (card output to control
Valve 3010 (complete)
panel)
BOX Interface box (Valve / Control panel) S1 (VRP) VRP closing control sensor
C1 VRP chamber S2 (VBC) VB closing control sensor
C2 Inlet chamber S3 (VBO) VB opening control sensor
C3 VB outlet chamber SCC Starting Current Control
C4 VRP pilot spool chamber SM Stepping motor
CARD Electronic card TO Oil thermostat
CHG Exchange TT Temperature transducer
D UP Upward / Up - upward starting command
Downward signal
(card to control panel)
DAL Auxiliary levelling device V0 Speed : high
DIR Direct V1 Speed : medium
DLV A3 DLV A3 Valve V2 Speed : inspection
DN Downward V3 Speed : fine levelling
FLT Filter VAL Valve (Valve only)
ISP Inspection gauge fitting VB Main flow adjustment valve
J Jack VC Rupture valve
J 1:1 Direct Jack 1:1 VMD Downward solenoid valve
K Non-return valve VML Levelling solenoid valve
M, Ma Motor VMP Starting solenoid valve (Y-D / SCC)
M1 VRP spool VP Pressure valve
MAN Pressure gauge VR Non-return valve (flow outlet)
ML Manual lowering button VR1 Non-return valve (inlet)
MP Motor / pump VR2 Non-return valve (outlet)
MPS Maximum pressure spool VRa Non-return valve (flow outlet) - Auxiliary
NGV NGV Valve (Complete) VRF Flow regulation valve
NGV-A3 NGV A3 Valve (Complete) VRFP Ausiliary flow regulation valve
OFF Powered off VRP Non-return valve - controlled
OLD, OVL Full load pressure limit switch VS Pilot valve, Upward signal [NGV]
ON Powered VS1, VS10 Pressure safety valve
OPP MPS pilot valve VSMA manual / electrical Lowering valve
Y, Δ, Y-Δ Star, Delta, Star-Delta

VALVE 3010/S + DLV A3 TABLE : 04.008.EN VER.: D


HYDRAULIC CIRCUIT DATE : 02.04.2014 2/2