You are on page 1of 2

EE310 Electromechanical

Level Measuring System


FEATURES
Analog output: 0-20mA/4-20mA.
Pulse output: NPN/PNP (10mm/pulse).
Relay output (5A/240Vac)×4: HI, LO alarm or Pulse, reset,
fault alarm, operation indication or Lock alarm output can
be programmed.
Plumb Buried Protection: System can sense and stop the
measurement as the plumb hit by materials and retrieve
the wire to prevent the plumb being buried.
Four Start Modes: auto start, manual start, intelligent start,
and external triggered start.
Intelligent Start: Measuring interval is inverse proportional
to medium level.
Material feeding protection switch: By connecting to
feeding equipment, when signal is (ON) to immediately
interrupt the measurement action and forcefully return the
plumb to reduce the risk of being buried.
RS485 MODBUS communication protocol.
Freeze Prevention Capability: being able to work normally
in cold temperature.

PRODUCT INTRODUCTION DIMENSION


EEX series Electro-Mechanical Level Measuring System (Unit:mm)

consists of plumb, cable wire, measuring pulley, position


304 238
sensor, and control board to measure the material level.
270 190
It senses the weight status and count the cable wire length
from the device to the level of material. The equips with robust
position sensor to calculate the numbers of rotating circles of
pulley, which can be operated in harsh environment.
330
100

APPLICATION
The result of measurement is not affected by
environmental factors as sound waves, dust, static
179

electricity, humidity and dielectric etc.


Can be widely applied for applications in mining, cement,
petrochemical, feeding and power plants.
Suitable for different variety of materials as powder, pellet,
460

liquid, and also good for open tanks or sealed tank with no
inner pressure inside.
Working perfectly with software of material management
system (MMS), accurately monitoring and managing the
level of materials inside the tank.
70

It features multifunction in on, needn’t extra controlling box,


connecting to panel for a immediate usage is available.
Front View Side View

08-EE310-D0-ED,10/27/2020
SPECIFICATION
Power supply AC type: 100~240Vac, 50/60Hz Ambient tempe. -40BC~60BC
(By order) DC type: 20~28Vdc Operating temp. -40BC~80BC
NPN & PNP (Transistor) max. 60Vdc, Ambient tempe. max.30m
Pulse output max. 400mA Protection rating IP66
Accuracy: ±5pulse(10mm/pulse) Body material Aluminium
Display LCM Graphic 128x64 Dots
SPDT 5A/240Vac X4
Accuracy: ±1pulse (100mm/pulse) Status LED Indication for Power/Run Signal/Abnormal
Relay 1: Pulse / HI Alarm Anti-Freeze Start heating <16BC
Relay output
Relay 2: Reset / LO Alarm heater (freeze prevention, prevent dew)
Relay 3: Failure Communication
Relay 4: Run Signal / Lock protocol RS485

Analog output 0/4~20mA ±1% Cable wire f1.2mm

ORDER INFORMATION
09 10 11 18 19 20 21 22 23 25 26 27 28 29

EEX 2 0 0 0 0 -999 272850 999999 0 99999


09 10 ANTI-FREEZE HEATER
00: N/A 01: With Heater

11 POWER SUPPLY
C:100~240Vac,50/60Hz D:20~28Vdc

18 19 20 21 22 23 CONNECTION
Code 000000
Name
180 ※Flanges For Standard Model:
90B 4"x5kg/cm2、4"x10kg/cm2、4"x16kg/cm2、
Type 45B 4"x20kg/cm2、4"x150Lbs
P.C.D
.f160
180
DN100 PN6 、DN100 PN10、DN100 PN16、
4-f19 DN100 PN25、DN100 PN40
18.8B

25 SENSING WEIGHT TYPE


Code A B C D
Standard type Float type Umbrella Auto-Fall-Off
Name
Stainless steel Stainless steel Stainless steel Plastic

f60

50 280
Type
Option f82
142
70 f20
75

※Custom made is available for sensing weight

26 27 28 29 LENGTH
Code Probe Length
3000 3000mm(3m)(Minimum)
A300 30000mm (30m) Maximum "A" means multiplied by 100 times

No.16, Tzuchiang St., Tucheng, District New Taipei City, Taiwan.


TEL : 886 2 22696789 │ FAX : 886 2 22686682 │ http://www.fine-tek.com
Email: info@fine-tek.com