You are on page 1of 5

Motion Radar Sensor

Type RAD01 and RAD02


• K-Band radar sensor compatible with all
types of automatic doors.
• 3-D adjustable sensor position offers precise
orientation of the activation pattern.
• Microprocessor technology filters out possible
weather condition interferences
• IR remote controller can be added for easy
adjustment
• UL325 approved

RAD 01 RAD 02

Product Description Ordering Key RAD 01


Motion Radar Sensor is a remote controller. Mounting Type
digital uni or bidirectional height up to 4m (13.12ft) also Detection mode
motion sensor for trouble-free available in uni- or
opening of all types of bidirectional mode to detect
automatic doors (sliding, motion towards or away from
swinging, folding, revolving, the device. Like most of other
speed-doors, overhead microwave detectors,
doors, etc...), for pedestrian equipped with planar flat
and civil applications. antenna, Carlo Gavazzi Radar
It can be adapted to every activates automatic doors
application without further utilizing doppler shift effect for
accessories and can be detecting movements.
controlled by an infrared

Type Selection
Detection mode Ordering no.

Bidirectional* RAD01
Uni & Bi-directional* RAD02
* Bidirectional: to detect motion towards and away from the sensor
Uni&Bidirectional: to detect motion towards and/or away from the sensor.

Electrical Data Environmental Data


Frequency emitted (K-Band) 24.125GHz Temperature range -20°C to +70°C
Radiated power <16dBm EIRP (-4°F to +158°F)
Rated supply voltage 12 – 24VAC ±10% Humidity from 0% to 90%RH
12 – 24VDC +30% / -10% Immunity R&TTE 1999/5/EC
Main frequency 50 to 60HZ EMC 89/336/EEC
Power consumption < 1W (VA) Max. mounting height 4m (13.12ft)
Output Relay SPDT Protection degree IP54
Rated Voltage 30VAC/DC
Max switching current 1A (resistive load)
Max switching power 30W (resistive load) Mechanical Data
Hold time 0.5 – 9s (adjustable)
Housing Material Polycarbonate
Dimensions WxHxD 118 x 80 x 53mm
(4.645 x 3.149 x 2.086inch.)
Weight 150g (5.29oz)
Cable length 2.5m (8.20ft)
Colour Glossy/Translucid Black

Specifications are subject to change without notice (28.11.2012) 1


RAD01/02

Adjustments and Settings


Manual Setting Device By two buttons on main by a digital filter) It prevents
PCB board. some external noise as objects
Remote Setting Device IR remote controller (optional) carried by wind, strong rain, etc.
Reset to factory set Value 1 - Restore PIN security code Relay status
(only by PCB buttons) 2 - Restore all factory values Active, Passive, (only by PCB buttons)
It permits to fix the relay
status: normally open or close.
Sensitivity 10 levels (1 to 10) Automatic mode/ (only by IR remote controller)
It allows increment or Permanently Open/Close. It permits to enable or disable
decrement of detection field. normal sensor detection and
Relay hold time 10 levels (0.5 to 9s) set ON or OFF permanently
It fixes the maintenance’s relay output.
time of the relay status. AUTO / OPEN / CLOSE
Security code 4-digit PIN access code
Uni-bidirectional mode It sets direction mode detection (only by IR remote controller) It permits to lock or unlock
(only for uni-bidirectional device). optional remote controller
Immunity detection “Quasi-presence”, Normal mode, keyboard setting.
Increased Immunity (Implemented

General Data Drilling Plan mm (inches)

Sensing field orientation double mechanical adjustment,


lateral and vertical
Detection angle
Vertical 0° to 90° in 15° increments
Lateral +/- 30° in 7.5° increments

Clearance
100 (3.937”)

Minimum
(1.575”)
Sensing field shape

40
bidirectional model By Sensor module
orientation Ø 3 (1/8”)
Detecting area (mounting height 2.2m

(0.905”)
(h = 7.22ft)) Ø 3 (1/8”)
23
Wide sensing field 4m (W) x 2m (D)
(13.12ft (W) x 6.56ft (D))
Narrow sensing field 2m (W) x 2.5m (D) Ø 8 (5/16”)
(6.56ft (W) x 8.20ft (D))
Cable inlet
Detection mode
Only bidirectional to detect motions towards 13
and away from sensor (0.511”)
Uni & bidirectional to detect motions towards
or/and away from sensor
Motion detecting speed 0.05 - 1m/s (0.164 - 3.28fps)
(measured in the sensor axis)

Factory Default Value


The device is set up in factory at the following default values:
1. Sensitivity 10 (max level)
2. Relay hold time 1 (min: 0.5 sec)
3. Uni-Bidirectional Detection Mode Bi-directional (Uni-directional mode is available only for RAD 02)
4. Immunity detection Immunity: OFF
5. Relay Status: Passive
6. PIN security: 0000 - block disabled (only for remote controller)
At the first start up, the device loads the default values.

2 Specifications are subject to change without notice (28.11.2012)


RAD01/02

Electrical Connections
Red LED IR Receiver Green LED

Main Connector
Relay NO contact
Relay NC contact
Push Button DEC (-) Relay Common
Supply Voltage
Push Button INC (+) 12 to 24 VAC/DC
Planar Antenna 12 to 24 VAC/DC

Caution:
Power on the radar by Class2 or LVE transformer.
Do not power on the radar until all primary and
secondary wiring is completed.

Dimensions mm (inches)

RAD 01

Lateral View Frontal View Top View

RAD 02

Lateral View Frontal View Top View

Specifications are subject to change without notice (28.11.2012) 3


RAD01/02

Sensing field adjustments


Mechanical sensor orientation

Planar antenna Planar antenna


vertical angle vertical angle

45° 15°

Adjust the vertical position to obtain the vertical sensing field close or far from the door.

Lateral angle rotation -15° Lateral angle rotation 0° Lateral angle rotation 15°
Adjust the lateral position to obtain the desired lateral angle sensing field.

4 Specifications are subject to change without notice (28.11.2012)


RAD01/02

RAD 01 Bidirectional Model


Detection area vs Sensitivity value (vertical angle 45°); Detection area vs Sensitivity value (vertical angle 45°);
vertical mount mode. horizontal mount mode.

4
0
6
2
8
4

4
8
2
6
0
4
6
0
4
4
0
6
2
8
4

4
8
2

0
0

9.8
8.2
6.5
4.9
3.2
1.6

1.6
3.2
4.9
6.5
8.2
9.8
ft
6.5
8.2
9.8
9.8
8.2
6.5
4.9
3.2
1.6

1.6
3.2
4.9

ft
3.0 2.5 2.0 1.5 1.0 0.5 0 0.5 1.0 1.5 2.0 2.5 3.0 m 3.0 2.5 2.0 1.5 1.0 0.5 0 0.5 1.0 1.5 2.0 2.5 3.0 m

0.5 0.5
20 56 92 28 64

64
S2
8. 6. 4. 3. 1.

1.
S4
1.0 S4
1.5 S6
1.5

92
S8

4.
2.0
S10 S6
2.5 2.5

20
8.
h = 2.2m h = 2.2m
3.0
ft 4
8

h = 7.22ft
9.

m S8 h = 7.22ft

8
3.5

.4
11
S10

ft 76
4.5

.
14
m

RAD 02 Uni & Bidirectional Model


Detection area vs Sensitivity value (vertical angle 15°). Detection area vs Sensitivity value (vertical angle 45°).

4
0
6
2
8
4

4
8
2
6
0
4
4
0
6
2
8
4

4
8
2
6
0
4

0
0

9.8
8.2
6.5
4.9
3.2
1.6

1.6
3.2
4.9
6.5
8.2
9.8
9.8
8.2
6.5
4.9
3.2
1.6

1.6
3.2
4.9
6.5
8.2
9.8

ft
ft

3.0 2.5 2.0 1.5 1.0 0.5 0 0.5 1.0 1.5 2.0 2.5 3.0m 3.0 2.5 2.0 1.5 1.0 0.5 0 0.5 1.0 1.5 2.0 2.5 3.0 m
S1
0.5 0.5 0
64
92 28 64

1.

S5
6. 4. 3. 1.

S1
1.0 S10
1.5 1.5
92
4.

S5
2.0
ft 6
5

m
2.5
20
8.

h = 7.22ft S8
h = 2.2m
h = 2.2m h = 7.22ft
8

3.5
.4
11

S10
ft 76

4.5
.
14

Note: S1...S10 sensitivity levels setting.

Sensing field adjustment according to


Sensitivity setting and mounting Height Accessory RAD 00 RC
The sensing field area size (lobo) depends on the sensitivity Type
parameter setting and the radar mounting height. IR remote controller

Door Status:
OPEN: Locked open Numeric keys
CLOSE: Locked closed
AUTO: automatic
detection mode RAD-00-RC
DOOR Hold time setting
F OPEN CLOSE AUTO

1 2 3 4 5

6 7 8 9 0 PIN Change
TIME +
Sensitivity setting SENS +
SENS -

Remote controller Lock TIME -


Remote controller Unlock
PIN

IMM QP
“Quasi Presence”
selection

Immunity selection
Detection mode
(only for RAD 02 model)

Specifications are subject to change without notice (28.11.2012) 5

You might also like