You are on page 1of 1

E D C B A

E D C B A 1 2 2' 3
2

4.50 4.00 2.00


3.00 1.50 4.00 2.00 4.50 3.00 1.50
3.00

0.60

0.60
TOP OF TRUSS 2 R TOP OF TRUSS 1 TOP OF TRUSS 2 TOP OF TRUSS 1
0.40 1.85 1.25 0.85
TOP OF R.B. 2 TOP OF R.B. 2
1 R TOP OF R.B. 1 R R TOP OF R.B. 1
W WR
3

VERIFY

VERIFY
EC

VERIFY

VERIFY
3.00

3.00
ROOF 2 LINE
1.50

EWT&B
D3 W WR WR WR
PLAIN
2' EW CEMENT W W W W W
SMOOTH FIN. FLR. LN. D D FIN. FLR. LN. FIN. FLR. LN. D FIN. FLR. LN.
4.50

FINISH
N.G.L. N.G.L. N.G.L. N.G.L.
3.00

W EW ROOF 1 LINE
D4

0.16

0.16
1.25
W W
ROOF 2 LINE

FRONT ELEVATION RIGHT SIDE ELEVATION

9.00
2 EC EC 2 3
EW
EW
1 A-2 SCALE 1:100 M A-2 SCALE 1:100 M
4.50

4.50
W EW EW W WR W

EW
WR WR
1 EC D2
W WR W W D1

1.25
0.40

ROOF 1 LINE
1 FLOOR PLAN
PLAIN CEMENT 3.00 1.50 4.00 2.00 1.25
SMOOTH FINISH
10.50
A-2 SCALE 1:100 M

2
A B C D E 3 2' 2 1

D C B A

VERIFY
2.00 4.00 1.50 3.00 1.50 3.00 4.50

0.60
TOP OF TRUSS 1 R TOP OF TRUSS 2 TOP OF TRUSS 2 TOP OF TRUSS 1
1.25 4.00 2.00 1.25
TOP OF R.B. 1 TOP OF R.B. 2 TOP OF R.B. 2 R
R R TOP OF R.B. 1
ROOF 1 LINE

VERIFY

VERIFY
CE
1.25

VERIFY
VERIFY

VERIFY
3.00
WR WR WR WR
2 W

D W W W W
FIN. FLR. LN. FIN. FLR. LN. FIN. FLR. LN. FIN. FLR. LN.

CE CE CE N.G.L. N.G.L. N.G.L. N.G.L.


4.50

7.00

0.16

0.16
4 REAR ELEVATION LEFT SIDE ELEVATION
5
A-2 SCALE 1:100 M
1 A-2 SCALE 1:100 M
1.25

CE 8 REFLECTED CEILING PLAN (1ST BLDG)


ROOF 1 LINE A-2 SCALE 1:100 M
8.50

LEGEND
W
WINDOW OPENINGS FOR REPAIR, STEEL GRILLES FOR DISMANTLING. SEE REHABILITATION
DETAILS
E D C B A 1 2 2' 3
D1 FOR DISMATLING AND REPLACEMENT. SEE REHABILITATION DETAILS
CHB WALL PLAIN
CHB WALL PLAIN CEMENT SMOOTH
D2 FOR DISMATLING AND REPLACEMENT. SEE REHABILITATION DETAILS CEMENT SMOOTH FINISH
FINISH 3.00 1.50 4.00 2.00 4.50 3.00 1.50
0.60

0.60
D3 FOR DISMATLING AND REPLACEMENT. SEE REHABILITATION DETAILS TOP OF TRUSS 2 TOP OF TRUSS 1 TOP OF TRUSS 2 TOP OF TRUSS 1
TOP OF R.B. 2 TOP OF R.B. 2
D4 FOR DISMATLING AND REPLACEMENT. SEE REHABILITATION DETAILS TOP OF R.B. 1 TOP OF R.B. 1
B B

VERIFY

VERIFY
VERIFY

VERIFY
EW EXISTING CHB WALLS FOR DISMANTLING.
3.00

3.00
W
WR EXISTING CHB WALLS, TO BE RETAINED AND REPAIRED. W W W D
FIN. FLR. LN. OPEN FIN. FLR. LN. FIN. FLR. LN. OPEN FIN. FLR. LN.

EC EXISTING CONCRETE COLUMNS FOR DISMANTLING. N.G.L. N.G.L. N.G.L. N.G.L.

0.16

0.16
B FIRST BUILDING ROOF BEAMS FOR DISMANTLING.
6 SECTION THRU "1-1" SECTION THRU "2-2"
OLD ROOFING STRUCTURE (TRUSSES, PURLINS, G.I. SHEETS, ETC.)OF THE FIRST AND 7
R
EXTENSION BUILDINGS FOR DISMANTLING AND REPLACEMENT (SEE REHAB. PLANS)
A-2 SCALE 1:100 M
A-2 SCALE 1:100 M
CE CEILING, CEILING JOISTS AND HANGERS FOR DISMANTLING

OWNER PROJECT TITLE/LECATION SHEET CONTENTS DRWN. CHKD. RECOMMENDING APRROVAL APPROVED SHEET NO.

AS SHOWN IRMA R. RODIS


EDGAR A. ABRIOL PROFESSIONAL AGRICULTURAL ENGINEER
PRC: 3859
REMEDIOS V. ABGONA, PhD KENNEDY T. COSTALES A-2
CHKD.
PTR: N/A CHIEF, FIBER UTILIZATION AND TECHNOLOGY DIVISION EXECUTIVE DIRECTOR
3/F DA-PCAF BLDG., DEPARTMENT OF AGRICULTURE 2 4
ELLIPTICAL ROAD, DILIMAN, QUEZON CITY BRGY. MALABOR,TIBIAO, ANTIQUE ENGR. EMMA Z. BALABIS
TIN: N/A
DATE: 05/28/2018

You might also like