Excellence for Automation

Communication Capability Digital Protection IEDs


► Support SV, GOOSE service of process layer ► Support all main protocols
application in accordance with IEC 61850-8-1, ● IEC 60870-5-103 serial or TCP/IP
IEC 61850-9-2, IEC 61850-9-2LE ● DNP 3.0
► Support MMS, GOOSE service of station layer ● MODBUS
and bay layer application in accordance with ► Support several time synchronizing way
IEC 61850-8-1 ● IRIG-B electrical/optical
► Seamless communication by PRP ● Pulse
► Adaption to the existing automation system with ● SNTP
several Ethernet ports or serial communication ● IEEE 1588
ports in one module ► Proven technology from thousands of
► Support IEC 62351 security standard operated digital substations

SIFANG protection IED family covers the whole electrical power system applications ranging
from 1000kV Ultra-high voltage power gird to 6kV industrial end users including power
generation, AC/DC transmission, distribution, industrial (e.g. petrochemical, iron and steel,
HMI metallurgy), rail transportation and commercial power consumption. Up to now, more than
1,000,000 protection IEDs have been in service reliably.
Switch

Protection
IED

Switch Switch
HIGHLIGHTS
Indoor

Outdoor
SCU AMU+SCU AMU+SCU
► Powerful scalable hardware capability, ► Robust hardware with excellent EMC
for present and future application performance and IP54 protection under
● Mixable CT&VT inputs / SV -40℃ to 70℃ operating temperature
Bay A Bay B Bay A Bay B Bay A Bay B Bay A Bay B (Sampling Value) input /output ► Completely Fully proven protection
Station layer: MMS/GOOSE, PRP Station layer: MMS/GOOSE, PRP Station layer: MMS/GOOSE, PRP Station layer: MMS/GOOSE, PRP
Bay layer: GOOSE, PRP Bay layer: GOOSE, PRP Bay layer: GOOSE, PRP Bay layer: GOOSE, PRP ● Mixable Binary inputs & output functions library
Process layer: Process bus, GOOSE; PRP Process layer: SV/GOOSE, PRP Process layer: Process bus, SV/GOOSE; PRP

relays / GOOSE inputs /outputs ► Vi s u a l i z e d I E D a c t i o n p r o c e s s w i t h


► Complying with IEC 61850 standard, complete record of internally calculated
supporting Sampled Value (SV) and variables (such as differential current) and
Generic Object-Oriented Substation internal logic elements in whole fault
BEIJING SIANG AUTOMATION CO., LTD. Event (GOOSE) process for simple fault analysis
9 Shangdi 4th Street, Haidian District, Beijing, P.R.C.100085

Website: www.sifang-electric.com
E-mail: sf_sales@sf-auto.com
Tel: +86 10 82181545