115-3:2009
Safety of escalators
and moving walks
Part 3: Correlation between EN
115:1995 and its amendments and EN
115-1:2008
ICS 91.140.90
National foreword
ICS 91.140.90
English Version
Sécurité des escaliers mécaniques et trottoirs roulants - Sicherheit von Fahrtreppen und Fahrsteigen - Teil 3:
Partie 3: Corrélation entre l'EN 115:1995 et ses Übereinstimmung zwischen EN 115:1995 und ihrer
amendements et l'EN 115-1:2008 Ergänzungen und EN 115-1:2008
This Technical Report was approved by CEN on 31 August 2009. It has been drawn up by the Technical Committee CEN/TC 10.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
© 2009 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TR 115-3:2009: E
worldwide for CEN national Members.
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Contents Page
Foreword ..............................................................................................................................................................3
Introduction .........................................................................................................................................................4
1 Scope ......................................................................................................................................................5
2 Correlation between EN 115:1995 and EN 115-1:2008 .......................................................................5
Bibliography ..................................................................................................................................................... 24
2
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Foreword
This document (CEN/TR 115-3:2009) has been prepared by Technical Committee CEN/TC 10 “Lifts,
escalators and moving walks”, the secretariat of which is held by AFNOR.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
3
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Introduction
This guide has been prepared to allow the user to compare the former standard EN 115:1995, including
amendments A1 and A2, with the revision EN 115-1:2008.
The revision of the standard was mandated by CEN with reference to the 10-year updating of European
Standards and to bring the standard in line with EN 414 in terms of structure and content.
The revision of EN 115 on this basis has resulted in a total restructuring of the document in line with the rules
in EN 414 and the determination of safety requirements has been reviewed based upon hazard analysis and
risk assessment.
Additionally safety requirements related exclusively to the machine are contained in Clause 5 of the revised
standard. Other safety requirements are detailed in the annexes, some of which are normative and others
informative.
4
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
1 Scope
This technical report applies to escalators and moving walks built in accordance with EN 115-1:2008.
Each clause is cross-referenced to its equivalent clause and the table illustrates the status of the text or
requirement. Guidance is given on whether the clause has remained unchanged, is modified, is new or has
been deleted.
Where appropriate a short explanation is given in the "Remarks" column to highlight changes and new
requirements contained in the revision of EN 115-1:2008.
5
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 1 - Correlation between EN 115 (incl. amendments) and EN 115-1:2008 (order of EN 115)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
6
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 1 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
nd
5.1.5.7.1 (1) 5.5.2.6, 2 X
sentence
5.1.5.7.1 (2) 5.5.2.6.1 X
5.1.5.7.2 5.5.2.6.2 X
5.1.5.8 5.5.2.5 X
5.1.5.9 5.5.4.1 X
5.2.1 (1) Annex A.2.5 X
5.2.1 (2) Annex A.2.6 X
- Annex A.2.7 X Requirement for protection against falling from the
landing
5.2.2 5.7.1 X Now includes definitions for materials and test
methods for anti-slip properties (Annex J)
5.2.3 Annex A.2.1 X
5.2.4 Annex A.2.4 X Reference point for b9 changed to outer edge
5.3 5.2.5 X Requirement for public service machines (1/1000)
deleted
5.4.1 Annex A.2.8 X
5.4.2 Annex A.2.9 X All lighting levels defined as 50 lx
5.5 5.10 X
6.1 Annex A.3.2 X Requirement for machinery space access to be
lockable
6.1 (1) 5.2.3 X
6.1 (ex 1) 5.8.1 (1,2) X
6.2.1 (1) Annex A.3.1 X
6.2.1 (2) Annex A.3.6 (1) X
6.2.2 - X
6.3.1.1 5.8.2.1 X
- 5.8.2.2 X Requirement for lifting attachments
6.3.1.2 5.8.2.3 X
6.3.1.3 (ex c) Annex A.3.5 X
6.3.1.3 c) Annex A.3.6(2) X
6.3.1.4 Annex A.3.7 X
6.3.2 (1) Annex A.3.3 X Requirements for lighting levels
st
1 sentence
- Annex A.3.4 X Requirement for emergency lighting
7
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 1 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
8
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 1 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
9
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 1 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
st
9.1.2 (2) 5.4.3.2 (2) ex 1 X New material specifications and tensile test
sentence
9.1.2 (3) 5.4.3.2 (3) X
9.1.3 5.4.3.3 X Criteria for tensioning device movement
9.2.1 5.4.4.1 X Requires worst case calculation for force
9.2.2 5.4.4.2 X
9.3 - X
10.1.1 5.2.2 X
10.1.2 5.3.1 (1) X Defines tolerances (see also old 8.2.3.1)
10.1.3 (1) 5.7.2.1 (1) X
10.1.3 (2) 5.7.2.1 (4) X
10.1.3 (3) 5.7.2.1 (2,3) X Upper limit and speed amended
10.1.4 5.7.2.2 X Intermediate speed radius of curvature included
for upper transition and lower transition radius of
curvature above 0,65 m/s
10.1.5 5.7.2.3 X
10.1.6 5.7.2.4 X
10.2.1 (1) 5.3.4 (1) X Maximum dimensions are defined
10.2.1 (2) 5.3.4 (2) X
10.2.2 5.7.2.5 (1,2) X
11.1 5.3.5 (1,3) X
- 5.3.5 (2) X Requirement for demarcation
- 5.3.6 X Requirement for detection of missing step/pallet
11.2.1 5.5.5.1 X
11.2.2 5.5.5.2 X
11.3.1 5.7.3.3.1 X Standardisation of mesh depth for steps, pallets
and belts
11.3.2 5.7.3.3.2 X
11.4.1 5.7.3.3.1 X
11.4.2 5.7.3.3.2 X
12.1 5.4.1.1 X
12.2.1 5.4.1.2.2 X
12.2.2 5.4.1.2.3 (1) X
12.2.2.1 5.4.1.2.3 (2) X
12.2.2.2 5.4.1.2.3 (3) X
10
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 1 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
12.2.3 5.4.1.2.1 X Defines the limits for nominal speed; the term
"rated speed" is no longer used in EN 115-1 .
12.3.1 5.4.1.3.1 X
12.3.2 5.4.1.3.2 X Defines more clearly safety factors for all drives
12.4.1 5.4.2.1.1.1 (1) X
- 5.4.2.1.1.1 (2) X Excess stopping distance failure lock requirement
12.4.1.1 5.4.2.1.1.2 X
12.4.1.2 5.4.2.1.1.3 X
12.4.2 (1,3) 5.4.2.1.2 (1,3) X
12.4.2 (2) 5.4.2.1.2 (2) X Deletes the requirement for brake force to be
generated by weights
- 5.4.2.1.1.1 (3) X Requirement for brake lift monitoring
12.4.3 5.4.2.1.1.4 X
12.4.4.1 5.4.2.1.3.1 X
12.4.4.2 5.4.2.1.3.2 (1,2,3) X
- 5.4.2.1.3.2 (4) X Specifies maximum deceleration rate
12.4.4.3 5.4.2.1.3.3 X Improvement of wording
12.4.4.4 (1,2,3,5) 5.4.2.1.3.4 X
(1,2,3,5)
12.4.4.4 (4) - X Replaced by the note in 5.4.2.1.3.4
- 5.4.2.1.3.4 (4) X Specifies maximum deceleration rate
nd
12.5.1 5.4.2.3.1 X Generalisation of 2 paragraph
12.5.2 5.4.2.3.2 X
12.6.1 5.4.2.2.1 X Improved wording
12.6.2 5.4.2.2.2 (1) X Deceleration requirement added
12.6.3 5.4.2.2.3 X
12.6.4 5.4.2.2.4 X
12.6.5 5.4.2.2.5 X
12.6.6 5.4.2.2.2 (2) X
12.7 (1,3) 5.4.1.4 (1,3) X
12.7 (2) - X
- 5.4.1.4 (2) X Requirement for electric safety device
12.8 5.4.1.5 X
12.9 5.8.1 (3) X
13.1 5.11.1.1 X
11
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 1 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
13.1.1.1 5.11.1.2.1 X
13.1.1.2 5.11.1.2.2 X
13.1.2 5.11.1.3 X Specified now by EN 60204-1
13.1.3 5.11.1.4 X Specified now by EN 60204-1
13.1.4 5.11.1.5 X
13.1.5 5.11.1.6 X Specified now by EN 60204-1
13.2. 5.11.2 X
13.3 5.11.3 X
13.4 5.11.4 X
13.5.1 5.11.5.1 X
13.5.2 5.11.5.2 X
13.5.3.1 5.11.5.3.1 X
13.5.3.2 - X Covered by 5.11.1.2
13.5.3.3 5.11.5.3.2 X
13.5.3.4 5.11.5.3.3 X
13.5.3.5 - X Covered by EN 60204-1
13.5.4 5.11.5.4 X
13.6.1 5.8.3.1 X
nd
2 sentence
13.6.2 5.8.3.3 X
13.7 5.11.6
- 5.11.7 X Requirement for protection against electrostatic
loading
14.1.1 5.12.1.1.1 X
14.1.1.1 5.12.1.1.2 X Requirement to consider phase reversal fault
14.1.1.2 5.12.1.1.3 X
14.1.1.3 5.12.1.1.4 X
14.1.2.1.1 5.12.1.2.1.1 X
14.1.2.1.2 5.12.1.2.1.2 X Defines exceptions
14.1.2.1.3 5.12.1.2.1.3 X
14.1.2.1.4 5.12.1.2.1.4 X
14.1.2.1.5 - X Covered by requirements in Annex B
14.1.2.1.6 - X Replaced by the requirements in 5.12.1.2.1.1
14.1.2.1.7 5.12.1.2.1.5 X
14.1.2.2 5.12.1.2.2 X
12
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 1 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
14.1.2.3 5.12.1.2.3 X
14.1.2.4 (1) 5.12.1.2.4 X
14.1.2.4 (2,3) - X 5.12.1.2.1.1 defines how safety switches and
safety circuits shall operate.
14.1.2.5 5.12.1.2.5 X Test requirements moved to D.3.1 and D.3.2
14.2.1 5.12.2.1.1 (1) X
- 5.12.2.1.1 (2) X Clarification from 5.11.1
- 5.12.2.1.1 (3,4) X New requirement for remote starting
14.2.1.1 5.12.2.1.2 X New requirements for entering speed and
acceleration rate
14.2.1.2 5.12.2.1.3 X
14.2.2.1 5.12.2.2.1 X
14.2.2.2 5.12.2.2.2 X
14.2.2.3.1 5.12.2.2.3.1 X Positioning for stop switches for emergency
situations modified
14.2.2.3.2 5.12.2.2.3.2 X
14.2.2.4.1 5.12.2.2.4.1 X Additional requirements in Table 6
14.2.2.4.1.l) 5.7.2.5 (3) X Now defined more clearly in the text
14.2.2.4.2 5.12.2.2.4.2 X
- 5.12.2.2.4.3 X This requirement was previously identified in A.3
which was only informative.
14.2.3 5.12.2.3 X
14.2.4.1 5.12.2.4.1 X Restarting conditions revised in accordance with
Table 6
14.2.4.2 5.12.2.4.2 X Design solutions removed
14.2.5.1. 5.12.2.5.1 X
14.2.5.2 5.12.2.5.2 X
14.2.5.3 5.12.2.5.3 X Additional requirements for stop switch defined
14.2.5.4 5.12.2.5.4 X Specific reference to items in Table 6
- 6 X Provides indications of methods to verify
conformity
15.1.1 7.2.1.1 X
15.1.2.1 7.2.1.2.1 X Prohibition sign for push chairs; old Figure 7 not
Annex G necessary because of deflector devices.
Additional guidance regarding local conditions.
15.1.2.2 7.2.1.2.2 X
13
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 1 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
15.1.2.3 7.2.1.2.3 X
15.1.3 7.2.1.3 X
15.1.4 7.2.1.4 X
15.1.5 7.5 X
15.2 7.2.2 X
16.1 - X Operational requirement deleted
16.2 7.3 X Former 16.2.1.1.1 and 16.2.1.1.2 covered by
verification (Clause 6)
16.3 7.4 (ex e) X More detailed in EN 115-1
16.4 7.4 e) X More detailed in EN 115-1
Annex A.1 Annex B.1 X
Annex A.2 Annex B.2 X
Annex A.3 Annex E X
- Annex D.2 X General provisions added
- Annex D.3 X Test samples requirements added
Annex A.4.1 Annex D.4 X
Annex A.4.2 Annex D.5 X
Annex A.4.3 5.11.1.2.3 X Requirements now defined by EN 12015 and
EN 12016
Annex B Annex C X
Annex C 4 X New hazards included
Annex D.1 5.7.2.1 (3) X Requirement now defined
Annex D.2 5.7.2.2 X Requirement now defined
Annex D.3 Annex H.2 (1) X
- Annex A.1 X Required by structure according EN 414
- Annex A.3.2 X Requirement for machinery space access to be
lockable
- Annex A.4 X Provides details of electric supply and protection
requirements
- Annex F X Informative annex
- Annex G X New safety signs
- Annex J X Information on determining ant-slip properties
- Annex K X Information on determining friction coefficients
- Annex L X Interpretation sheet
14
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 2 - Correlation between EN 115 (incl. amendments) and EN 115-1:2008 (order of EN 115-1)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
15
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 2 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
5.3.2.3.1 8.2.4.1 X
5.3.2.3.2 8.2.4.2 X
5.3.2.3.3 8.2.4.3 X
5.3.2.3.4 8.2.4.4 X
5.3.2.3.5 8.2.4.5 X
5.3.3.1 (1,2,4) 8.2.1 (1) X Requirement for life cycle, torsional effects and
assembled steps and pallets introduced
5.3.3.1 (3) 8.2.1 (2) X
5.3.3.2.1 8.2.2.1.1 X
5.3.3.2.2 8.2.5 (1) X New strength requirements
5.3.3.2.3 8.2.2.1.2 X
5.3.3.2.4 8.2.4.6.1.1 X
5.3.3.3.1.1 (1,2,4) 8.2.2.2.1 X
5.3.3.3.1.1 (3) - X Requirements for components parts added
5.3.3.3.1.2 - X Requirement for torsional test
5.3.3.3.2.1 8.2.2.2.2 X
(1,2,3,5)
5.3.3.3.2.1 (4) - X Requirements for components parts added
5.3.3.3.2.2 - X Requirement for torsional test
5.3.4 (1) 10.2.1 (1) X Maximum dimensions are defined.
5.3.4 (2) 10.2.1 (2) X
5.3.4 (3) 8.2.4.6.1.2 X
5.3.5 (1,3) 11.1 X
5.3.5 (2) - X Requirement for demarcation
5.3.6 - X Requirement for detection of missing step/pallet
5.4.1.1 12.1 X
5.4.1.2.1 12.2.3 X Defines the limits for nominal speed; the term
"rated speed" is no longer used in EN 115-1.
5.4.1.2.2 12.2.1 X
5.4.1.2.3 (1) 12.2.2 X
5.4.1.2.3 (2) 12.2.2.1 X
5.4.1.2.3 (3) 12.2.2.2 X
5.4.1.3.1 12.3.1 X
5.4.1.3.2 12.3.2 X Defines more clearly safety factors for all drives
5.4.1.4 (1,3) 12.7 (1,3) X
16
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 2 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
- 12.7 (2) X
5.4.1.4 (2) - X Requirement for electric safety device
5.4.1.5 12.8 X
5.4.2.1.1.1 (1) 12.4.1 X
5.4.2.1.1.1 (2) - X Excess stopping distance failure lock requirement
5.4.2.1.1.1 (3) - X Requirement for brake lift monitoring
5.4.2.1.1.2 12.4.1.1 X
5.4.2.1.1.3 12.4.1.2 X
5.4.2.1.1.4 12.4.3 X
5.4.2.1.2 (1,3) 12.4.2 (1,3) X
5.4.2.1.2 (2) 12.4.2 (2) X Deletes the requirement for brake force to be
generated by weights
5.4.2.1.3.1 12.4.4.1 X
5.4.2.1.3.2 (1,2,3) 12.4.4.2 X
5.4.2.1.3.2 (4) - X Specifies maximum deceleration rate
5.4.2.1.3.3 12.4.4.3 X Improvement of wording
5.4.2.1.3.4 12.4.4.4 (1,2,3,5) X
(1,2,3,5)
- 12.4.4.4 (4) X Replaced by the note in 5.4.2.1.3.4
5.4.2.1.3.4 (4) - X Specifies maximum deceleration rate
5.4.2.2.1 12.6.1 X Improved wording
5.4.2.2.2 (1) 12.6.2 X Deceleration requirement added
5.4.2.2.2 (2) 12.6.6 X
5.4.2.2.3 12.6.3 X
5.4.2.2.4 12.6.4 X
5.4.2.2.5 12.6.5 X
nd
5.4.2.3.1 12.5.1 X Generalisation of 2 paragraph
5.4.2.3.2 12.5.2 X
5.4.3.1 9.1.1 X
5.4.3.2 (1) - X Fatigue life requirement
st
5.4.3.2 (2) ex 1 9.1.2 (2) X New material specifications and tensile test
sentence
5.4.3.2 (2) 9.1.2 (1) X
st
1 sentence
5.4.3.2 (3) 9.1.2 (3) X
5.4.3.3 9.1.3 X Criteria for tensioning device movement
17
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 2 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
18
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 2 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
5.6.2.2 7.3.2 X
5.6.2.3 7.3.3 X
5.6.3 7.4 X
5.6.4.1 7.5.1 X
5.6.4.2 7.5.2 X Additional requirement to reduce risk of trapping
between handrail and floor plate
5.6.4.3 7.5.3 X
5.6.5 7.7 X
5.7.1 5.2.2 X Now includes definitions for materials and test
methods for anti-slip properties (Annex J)
5.7.2.1 (1) 10.1.3 (1) X
5.7.2.1 (2,3) 10.1.3 (3) X Upper limit and speed amended
5.7.2.1 (3) Annex D.1 X Requirement now defined
5.7.2.1 (4) 10.1.3 (2) X
5.7.2.2 10.1.4 X Intermediate speed radius of curvature included
Annex D.2 for upper transition and lower transition radius of
curvature above 0,65 m/s
5.7.2.3 10.1.5 X
5.7.2.4 10.1.6 X
5.7.2.5 (1,2) 10.2.2 X
5.7.2.5 (3) 14.2.2.4.1.l) X Now defined more clearly in the text
st
5.7.3.1 1 8.3.1 X
sentence
nd
5.7.3.1 2 8.3.2.4 (2) X
sentence
5.7.3.2.1 8.3.2.1 X
5.7.3.2.2 8.3.2.2 X
5.7.3.2.3 8.3.2.3 X Maximum angle reduced to 35°
5.7.3.2.4 8.3.2.4 (1) X
5.7.3.2.5 8.3.2.5 X Common requirement for all types of machine
5.7.3.2.6 8.3.2.6 X Improved wording
5.7.3.3.1 11.3.1 X Standardisation of mesh depth for steps, pallets
and belts
5.7.3.3.1 11.4.1 X
5.7.3.3.2 11.3.2 X
11.4.2
5.8.1 (1,2) 6.1 (ex 1) X
19
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 2 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
5.11.5.1 13.5.1 X
5.11.5.2 13.5.2 X
5.11.5.3.1 13.5.3.1 X
- 13.5.3.2 X Covered by 5.11.1.2
5.11.5.3.2 13.5.3.3 X
5.11.5.3.3 13.5.3.4 X
- 13.5.3.5 X Covered by EN 60204-1
5.11.5.4 13.5.4 X
20
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 2 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
5.11.6 13.7
5.11.7 - X Requirement for protection against electrostatic
loading
5.12.1.1.1 14.1.1 X
5.12.1.1.2 14.1.1.1 X Requirement to consider phase reversal fault
5.12.1.1.3 14.1.1.2 X
5.12.1.1.4 14.1.1.3 X
5.12.1.2.1.1 14.1.2.1.1 X
5.12.1.2.1.2 14.1.2.1.2 X Defines exceptions
5.12.1.2.1.3 14.1.2.1.3 X
5.12.1.2.1.4 14.1.2.1.4 X
- 14.1.2.1.5 X Covered by requirements in Annex B
- 14.1.2.1.6 X Replaced by the requirements in 5.12.1.2.1.1
5.12.1.2.1.5 14.1.2.1.7 X
5.12.1.2.2 14.1.2.2 X
5.12.1.2.3 14.1.2.3 X
5.12.1.2.4 14.1.2.4 (1) X
- 14.1.2.4 (2,3) X 5.12.1.2.1.1 defines how safety switches and
safety circuits shall operate.
5.12.1.2.5 14.1.2.5 X Test requirements moved to D.3.1 and D.3.2
5.12.2.1.1 (1) 14.2.1 X
5.12.2.1.1 (2) - X Clarification from 14.1.1
5.12.2.1.1 (3,4) - X New requirement for remote starting
5.12.2.1.2 14.2.1.1 X New requirements for entering speed and
acceleration rate
5.12.2.1.3 14.2.1.2 X
5.12.2.2.1 14.2.2.1 X
5.12.2.2.2 14.2.2.2 X
5.12.2.2.3.1 14.2.2.3.1 X Positioning for stop switches for emergency
situations modified
5.12.2.2.3.2 14.2.2.3.2 X
5.12.2.2.4.1 14.2.2.4.1 X Additional requirements in Table 6
5.12.2.2.4.2 14.2.2.4.2 X
5.12.2.2.4.3 - X This requirement was previously identified in A.3
which was only informative.
5.12.2.3 14.2.3 X
21
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 2 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
22
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Table 2 (continued)
Unchanged
Modified
Deleted
EN 115:1995
EN 115-1:
New
+A1:1998 Remarks
2008
+A2:2004
23
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)
Bibliography
[1] EN 115:1995, Safety rules for the construction and installation of escalators and passenger conveyors
[2] EN 115-1:2008, Safety of escalators and moving walks – Part 1: Construction and installation
[3] EN 414, Safety of machinery – Rules for the drafting and presentation of safety standards
[4] EN 12015, Electromagnetic compatibility – Product family standard for lifts, escalators and moving
walks – Emission
[5] EN 12016, Electromagnetic compatibility – Product family standard for lifts, escalators and moving
walks – Immunity
[6] EN 60204-1, Safety of machinery – Electrical equipment of machines – Part 1: General requirements
(IEC 60204-1:2005, modified)
24