PD CEN/TR 115-3:2009

National foreword

This Published Document is the UK implementation of CEN/TR


115-3:2009.
The UK participation in its preparation was entrusted to Technical
Committee MHE/4, Lifts, hoists and escalators.
A list of organizations represented on this committee can be obtained on
request to its secretary.
This publication does not purport to include all the necessary provisions
of a contract. Users are responsible for its correct application.
Compliance with a British Standard cannot confer immunity
from legal obligations.

This Published Document Amendments/corrigenda issued since publication


was published under the
authority of the Standards
Policy and Strategy Date Comments
Committee on 31 December
2009
© BSI 2009

ISBN 978 0 580 67063 3


PD CEN/TR 115-3:2009

TECHNICAL REPORT CEN/TR 115-3


RAPPORT TECHNIQUE
TECHNISCHER BERICHT November 2009

ICS 91.140.90

English Version

Safety of escalators and moving walks - Part 3: Correlation


between EN 115:1995 and its amendments and EN 115-1:2008

Sécurité des escaliers mécaniques et trottoirs roulants - Sicherheit von Fahrtreppen und Fahrsteigen - Teil 3:
Partie 3: Corrélation entre l'EN 115:1995 et ses Übereinstimmung zwischen EN 115:1995 und ihrer
amendements et l'EN 115-1:2008 Ergänzungen und EN 115-1:2008

This Technical Report was approved by CEN on 31 August 2009. It has been drawn up by the Technical Committee CEN/TC 10.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.

EUROPEAN COMMITTEE FOR STANDARDIZATION


COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels

© 2009 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TR 115-3:2009: E
worldwide for CEN national Members.
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Contents Page

Foreword ..............................................................................................................................................................3
Introduction .........................................................................................................................................................4
1 Scope ......................................................................................................................................................5
2 Correlation between EN 115:1995 and EN 115-1:2008 .......................................................................5
Bibliography ..................................................................................................................................................... 24

2
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Foreword
This document (CEN/TR 115-3:2009) has been prepared by Technical Committee CEN/TC 10 “Lifts,
escalators and moving walks”, the secretariat of which is held by AFNOR.

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.

3
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Introduction
This guide has been prepared to allow the user to compare the former standard EN 115:1995, including
amendments A1 and A2, with the revision EN 115-1:2008.

The revision of the standard was mandated by CEN with reference to the 10-year updating of European
Standards and to bring the standard in line with EN 414 in terms of structure and content.

The revision of EN 115 on this basis has resulted in a total restructuring of the document in line with the rules
in EN 414 and the determination of safety requirements has been reviewed based upon hazard analysis and
risk assessment.

Additionally safety requirements related exclusively to the machine are contained in Clause 5 of the revised
standard. Other safety requirements are detailed in the annexes, some of which are normative and others
informative.

4
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

1 Scope
This technical report applies to escalators and moving walks built in accordance with EN 115-1:2008.

2 Correlation between EN 115:1995 and EN 115-1:2008


This Technical Report is presented in the form of two tables. Table 1 provides a correlation between
EN 115:1995, including amendments A1:1998 and A2:2004, and EN 115-1:2008 based upon the
chronological clause references of EN 115. Table 2 provides a similar correlation but using EN 115-1:2008 as
the base document for comparison.

Each clause is cross-referenced to its equivalent clause and the table illustrates the status of the text or
requirement. Guidance is given on whether the clause has remained unchanged, is modified, is new or has
been deleted.

Where appropriate a short explanation is given in the "Remarks" column to highlight changes and new
requirements contained in the revision of EN 115-1:2008.

5
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 1 - Correlation between EN 115 (incl. amendments) and EN 115-1:2008 (order of EN 115)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

0.5.1 5.9 X Specified characteristics included


0.5.2 Introduction (11) X
0.5.3 Annex I X Restrictions of the use of shopping trolleys and
baggage carts
3.8 Annex H.1 X Maximum capacities defined (modified to reflect
achievable carrying capacity)
3.9 Annex H.2 (1) X
partly
5.1.1.1 5.2.1.1 X
5.1.1.2 5.2.1.3 X
5.1.1.3 5.2.1.4 X General comment on fire protection now in 5.9
5.1.2 5.2.1.2 X Now contains specific values for strength of the
enclosure and fixings
- 5.2.1.6 X New requirement for safety device
5.1.3.1 5.2.4 (1) X Requirement for safety switch
5.1.3.2 5.2.4 (2,3) X
5.1.3.3 - X Covered by 5.2.4 (1)
5.1.3.4 5.2.4 (4) X
5.1.4 5.2.1.5 X Improvement of former wording
5.1.5.1 5.5.1 X Definitions shifted to Clause 3
5.1.5.2 (1) 5.5.2.2 (1) X
5.1.5.2 (2) 5.5.2.2 (ex (1)) X Now contains specific dimensions and design
requirements
5.1.5.3 5.5.2.3 X Additional requirement for lateral force added
5.1.5.4 (1,2,3,4) 5.5.2.4 (1,2,3,4) X
5.1.5.4 (5) 5.5.2.4 (5) X Absolute requirement for toughened glass and
requirements for multi-layer glass defined
5.1.5.5 - X Specific information given in other clause
5.1.5.6 5.5.3.1 X
5.5.3.2
5.1.5.6.1 5.5.3.1 Note X
5.1.5.6.2 5.5.3.3 X
5.1.5.6.3 a) b) d) 5.5.3.4 a) b) c) X
5.1.5.6.3 c) 5.5.3.4 d) X Now includes specific values for coefficient of
friction for escalators
st
5.1.5.7 5.5.2.6, 1 X
sentence

6
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 1 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

nd
5.1.5.7.1 (1) 5.5.2.6, 2 X
sentence
5.1.5.7.1 (2) 5.5.2.6.1 X
5.1.5.7.2 5.5.2.6.2 X
5.1.5.8 5.5.2.5 X
5.1.5.9 5.5.4.1 X
5.2.1 (1) Annex A.2.5 X
5.2.1 (2) Annex A.2.6 X
- Annex A.2.7 X Requirement for protection against falling from the
landing
5.2.2 5.7.1 X Now includes definitions for materials and test
methods for anti-slip properties (Annex J)
5.2.3 Annex A.2.1 X
5.2.4 Annex A.2.4 X Reference point for b9 changed to outer edge
5.3 5.2.5 X Requirement for public service machines (1/1000)
deleted
5.4.1 Annex A.2.8 X
5.4.2 Annex A.2.9 X All lighting levels defined as 50 lx
5.5 5.10 X
6.1 Annex A.3.2 X Requirement for machinery space access to be
lockable
6.1 (1) 5.2.3 X
6.1 (ex 1) 5.8.1 (1,2) X
6.2.1 (1) Annex A.3.1 X
6.2.1 (2) Annex A.3.6 (1) X
6.2.2 - X
6.3.1.1 5.8.2.1 X
- 5.8.2.2 X Requirement for lifting attachments
6.3.1.2 5.8.2.3 X
6.3.1.3 (ex c) Annex A.3.5 X
6.3.1.3 c) Annex A.3.6(2) X
6.3.1.4 Annex A.3.7 X
6.3.2 (1) Annex A.3.3 X Requirements for lighting levels
st
1 sentence
- Annex A.3.4 X Requirement for emergency lighting

7
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 1 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

6.3.2 (1) 5.8.3.2 (1) X


nd rd
2 and 3
sentence
- 5.8.3.2 (2) X Requirement for lighting level
6.3.2 (2) 5.8.3.1 X
st
1 sentence
6.3.3 5.8.4 X
7.1 5.6.1 (1) X
- 5.6.1 (2) X Requirement on handrail speed monitoring
7.2 5.5.4.2 X
7.3.1 (1) (2) 5.6.2.1 X
7.3.1 (3) Annex A.2.2 X Requirement for vertical distance b12 defined
7.3.1 (4) Annex A.2.3 X Minimum distance increased to 160 mm
7.3.2 5.6.2.2 X
7.3.3 5.6.2.3 X
7.4 5.6.3 X
7.5.1 5.6.4.1 X
7.5.2 5.6.4.2 X Additional requirement to reduce risk of trapping
between handrail and floor plate
7.5.3 5.6.4.3 X
7.6 5.5.2.1 X
7.7 5.6.5 X
7.8 - X Requirement not necessary because of handrail
monitoring (see 5.6.1)
8.1.1 (1) 5.3.2.2.1 X
8.1.1 (2) - X Not a machinery safety item. Mentioned in the
Introduction.
8.1.2 5.3.2.2.2 X
8.1.3 (1) 5.3.2.1 (1) X
8.1.3 (2) 5.3.2.1 (2) X Maximum width of moving walk defined
8.2.1 (1) 5.3.3.1 (1,2,4) X Requirement for life cycle, torsional effects and
assembled steps and pallets introduced
8.2.1 (2) 5.3.3.1 (3) X
8.2.2.1.1 5.3.3.2.1 X
8.2.2.1.2 5.3.3.2.3 X
8.2.2.2.1 5.3.3.3.1.1 (1,2,4) X
- 5.3.3.3.1.1 (3) X Requirements for components parts added

8
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 1 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

- 5.3.3.3.1.2 X Requirement for torsional test


8.2.2.2.2 5.3.3.3.2.1 X
(1,2,3,5)
- 5.3.3.3.2.1 (4) X Requirements for components parts added
- 5.3.3.3.2.2 X Requirement for torsional test
st
8.2.3.1 1 part 5.3.2.3.3 X
nd
8.2.3.1 2 part 5.3.1 (1) X Defines tolerance
- 5.3.1 (2) X Specifies requirements for secure foothold
8.2.3.2 5.3.2.2.5 X
8.2.3.3 5.3.2.2.6 X
8.2.3.4 5.3.2.2.7 X
8.2.3.5 5.3.2.2.8 X
8.2.3.6 5.3.2.2.9 X
8.2.4.1 5.3.2.3.1 X
8.2.4.2 5.3.2.3.2 X
8.2.4.3 5.3.2.3.3 X
8.2.4.4 5.3.2.3.4 X
8.2.4.5 5.3.2.3.5 X
8.2.4.6.1.1 5.3.3.2.4 X
8.2.4.6.1.2 5.3.4 (3) X
8.2.5 (1) 5.3.3.2.2 X New strength requirements
8.2.5 (2) 5.3.2.2.4 X
st
8.3.1 5.7.3.1 1 X
sentence
8.3.2.1 5.7.3.2.1 X
8.3.2.2 5.7.3.2.2 X
8.3.2.3 5.7.3.2.3 X Maximum angle reduced to 35°
8.3.2.4 (1) 5.7.3.2.4 X
nd
8.3.2.4 (2) 5.7.3.1 2 X
sentence
8.3.2.5 5.7.3.2.5 X Common requirement for all types of machine
8.3.2.6 5.7.3.2.6 X Improved wording
9.1.1 5.4.3.1 X
- 5.4.3.2 (1) X Fatigue life requirement
9.1.2 (1) 5.4.3.2 (2) X
st
1 sentence

9
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 1 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

st
9.1.2 (2) 5.4.3.2 (2) ex 1 X New material specifications and tensile test
sentence
9.1.2 (3) 5.4.3.2 (3) X
9.1.3 5.4.3.3 X Criteria for tensioning device movement
9.2.1 5.4.4.1 X Requires worst case calculation for force
9.2.2 5.4.4.2 X
9.3 - X
10.1.1 5.2.2 X
10.1.2 5.3.1 (1) X Defines tolerances (see also old 8.2.3.1)
10.1.3 (1) 5.7.2.1 (1) X
10.1.3 (2) 5.7.2.1 (4) X
10.1.3 (3) 5.7.2.1 (2,3) X Upper limit and speed amended
10.1.4 5.7.2.2 X Intermediate speed radius of curvature included
for upper transition and lower transition radius of
curvature above 0,65 m/s
10.1.5 5.7.2.3 X
10.1.6 5.7.2.4 X
10.2.1 (1) 5.3.4 (1) X Maximum dimensions are defined
10.2.1 (2) 5.3.4 (2) X
10.2.2 5.7.2.5 (1,2) X
11.1 5.3.5 (1,3) X
- 5.3.5 (2) X Requirement for demarcation
- 5.3.6 X Requirement for detection of missing step/pallet
11.2.1 5.5.5.1 X
11.2.2 5.5.5.2 X
11.3.1 5.7.3.3.1 X Standardisation of mesh depth for steps, pallets
and belts
11.3.2 5.7.3.3.2 X
11.4.1 5.7.3.3.1 X
11.4.2 5.7.3.3.2 X

12.1 5.4.1.1 X
12.2.1 5.4.1.2.2 X
12.2.2 5.4.1.2.3 (1) X
12.2.2.1 5.4.1.2.3 (2) X
12.2.2.2 5.4.1.2.3 (3) X

10
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 1 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

12.2.3 5.4.1.2.1 X Defines the limits for nominal speed; the term
"rated speed" is no longer used in EN 115-1 .
12.3.1 5.4.1.3.1 X
12.3.2 5.4.1.3.2 X Defines more clearly safety factors for all drives
12.4.1 5.4.2.1.1.1 (1) X
- 5.4.2.1.1.1 (2) X Excess stopping distance failure lock requirement
12.4.1.1 5.4.2.1.1.2 X
12.4.1.2 5.4.2.1.1.3 X
12.4.2 (1,3) 5.4.2.1.2 (1,3) X
12.4.2 (2) 5.4.2.1.2 (2) X Deletes the requirement for brake force to be
generated by weights
- 5.4.2.1.1.1 (3) X Requirement for brake lift monitoring
12.4.3 5.4.2.1.1.4 X
12.4.4.1 5.4.2.1.3.1 X
12.4.4.2 5.4.2.1.3.2 (1,2,3) X
- 5.4.2.1.3.2 (4) X Specifies maximum deceleration rate
12.4.4.3 5.4.2.1.3.3 X Improvement of wording
12.4.4.4 (1,2,3,5) 5.4.2.1.3.4 X
(1,2,3,5)
12.4.4.4 (4) - X Replaced by the note in 5.4.2.1.3.4
- 5.4.2.1.3.4 (4) X Specifies maximum deceleration rate
nd
12.5.1 5.4.2.3.1 X Generalisation of 2 paragraph
12.5.2 5.4.2.3.2 X
12.6.1 5.4.2.2.1 X Improved wording
12.6.2 5.4.2.2.2 (1) X Deceleration requirement added
12.6.3 5.4.2.2.3 X
12.6.4 5.4.2.2.4 X
12.6.5 5.4.2.2.5 X
12.6.6 5.4.2.2.2 (2) X
12.7 (1,3) 5.4.1.4 (1,3) X
12.7 (2) - X
- 5.4.1.4 (2) X Requirement for electric safety device
12.8 5.4.1.5 X
12.9 5.8.1 (3) X
13.1 5.11.1.1 X

11
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 1 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

13.1.1.1 5.11.1.2.1 X
13.1.1.2 5.11.1.2.2 X
13.1.2 5.11.1.3 X Specified now by EN 60204-1
13.1.3 5.11.1.4 X Specified now by EN 60204-1
13.1.4 5.11.1.5 X
13.1.5 5.11.1.6 X Specified now by EN 60204-1
13.2. 5.11.2 X
13.3 5.11.3 X
13.4 5.11.4 X

13.5.1 5.11.5.1 X
13.5.2 5.11.5.2 X
13.5.3.1 5.11.5.3.1 X
13.5.3.2 - X Covered by 5.11.1.2
13.5.3.3 5.11.5.3.2 X
13.5.3.4 5.11.5.3.3 X
13.5.3.5 - X Covered by EN 60204-1
13.5.4 5.11.5.4 X
13.6.1 5.8.3.1 X
nd
2 sentence
13.6.2 5.8.3.3 X
13.7 5.11.6
- 5.11.7 X Requirement for protection against electrostatic
loading
14.1.1 5.12.1.1.1 X
14.1.1.1 5.12.1.1.2 X Requirement to consider phase reversal fault
14.1.1.2 5.12.1.1.3 X
14.1.1.3 5.12.1.1.4 X
14.1.2.1.1 5.12.1.2.1.1 X
14.1.2.1.2 5.12.1.2.1.2 X Defines exceptions
14.1.2.1.3 5.12.1.2.1.3 X
14.1.2.1.4 5.12.1.2.1.4 X
14.1.2.1.5 - X Covered by requirements in Annex B
14.1.2.1.6 - X Replaced by the requirements in 5.12.1.2.1.1
14.1.2.1.7 5.12.1.2.1.5 X
14.1.2.2 5.12.1.2.2 X

12
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 1 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

14.1.2.3 5.12.1.2.3 X
14.1.2.4 (1) 5.12.1.2.4 X
14.1.2.4 (2,3) - X 5.12.1.2.1.1 defines how safety switches and
safety circuits shall operate.
14.1.2.5 5.12.1.2.5 X Test requirements moved to D.3.1 and D.3.2
14.2.1 5.12.2.1.1 (1) X
- 5.12.2.1.1 (2) X Clarification from 5.11.1
- 5.12.2.1.1 (3,4) X New requirement for remote starting
14.2.1.1 5.12.2.1.2 X New requirements for entering speed and
acceleration rate
14.2.1.2 5.12.2.1.3 X
14.2.2.1 5.12.2.2.1 X
14.2.2.2 5.12.2.2.2 X
14.2.2.3.1 5.12.2.2.3.1 X Positioning for stop switches for emergency
situations modified
14.2.2.3.2 5.12.2.2.3.2 X
14.2.2.4.1 5.12.2.2.4.1 X Additional requirements in Table 6
14.2.2.4.1.l) 5.7.2.5 (3) X Now defined more clearly in the text
14.2.2.4.2 5.12.2.2.4.2 X
- 5.12.2.2.4.3 X This requirement was previously identified in A.3
which was only informative.
14.2.3 5.12.2.3 X
14.2.4.1 5.12.2.4.1 X Restarting conditions revised in accordance with
Table 6
14.2.4.2 5.12.2.4.2 X Design solutions removed
14.2.5.1. 5.12.2.5.1 X
14.2.5.2 5.12.2.5.2 X
14.2.5.3 5.12.2.5.3 X Additional requirements for stop switch defined
14.2.5.4 5.12.2.5.4 X Specific reference to items in Table 6
- 6 X Provides indications of methods to verify
conformity
15.1.1 7.2.1.1 X
15.1.2.1 7.2.1.2.1 X Prohibition sign for push chairs; old Figure 7 not
Annex G necessary because of deflector devices.
Additional guidance regarding local conditions.
15.1.2.2 7.2.1.2.2 X

13
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 1 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

15.1.2.3 7.2.1.2.3 X
15.1.3 7.2.1.3 X
15.1.4 7.2.1.4 X
15.1.5 7.5 X
15.2 7.2.2 X
16.1 - X Operational requirement deleted
16.2 7.3 X Former 16.2.1.1.1 and 16.2.1.1.2 covered by
verification (Clause 6)
16.3 7.4 (ex e) X More detailed in EN 115-1
16.4 7.4 e) X More detailed in EN 115-1
Annex A.1 Annex B.1 X
Annex A.2 Annex B.2 X
Annex A.3 Annex E X
- Annex D.2 X General provisions added
- Annex D.3 X Test samples requirements added
Annex A.4.1 Annex D.4 X
Annex A.4.2 Annex D.5 X
Annex A.4.3 5.11.1.2.3 X Requirements now defined by EN 12015 and
EN 12016
Annex B Annex C X
Annex C 4 X New hazards included
Annex D.1 5.7.2.1 (3) X Requirement now defined
Annex D.2 5.7.2.2 X Requirement now defined
Annex D.3 Annex H.2 (1) X
- Annex A.1 X Required by structure according EN 414
- Annex A.3.2 X Requirement for machinery space access to be
lockable
- Annex A.4 X Provides details of electric supply and protection
requirements
- Annex F X Informative annex
- Annex G X New safety signs
- Annex J X Information on determining ant-slip properties
- Annex K X Information on determining friction coefficients
- Annex L X Interpretation sheet

14
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 2 - Correlation between EN 115 (incl. amendments) and EN 115-1:2008 (order of EN 115-1)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

Introduction (11) 0.5.2 X


4 Annex C X New hazards included
5.2.1.1 5.1.1.1 X
5.2.1.2 5.1.2 X Now contains specific values for strength of the
enclosure and fixings
5.2.1.3 5.1.1.2 X
5.2.1.4 5.1.1.3 X General comment on fire protection now in 5.9
5.2.1.5 5.1.4 X Improvement of former wording
5.2.1.6 - X New requirement for safety device
5.2.2 10.1.1 X
5.2.3 6.1 (1) X
5.2.4 (1) 5.1.3.1 X Requirement for safety switch
5.2.4 (2,3) 5.1.3.2 X
- 5.1.3.3 X Covered by 5.2.4 (1)
5.2.4 (4) 5.1.3.4 X
5.2.5 5.3 X Requirement for public service machines (1/1000)
deleted
nd
5.3.1 (1) 8.2.3.1 2 part X Defines tolerances
5.3.1 (1) 10.1.2 X Defines tolerances (see also old 8.2.3.1)
5.3.1 (2) - X Specifies requirements for secure foothold
5.3.2.1 (1) 8.1.3 (1) X
5.3.2.1 (2) 8.1.3 (2) X Maximum width of moving walk defined
5.3.2.2.1 8.1.1 (1) X
- 8.1.1 (2) X Not a machinery safety item. Mentioned in the
Introduction.
5.3.2.2.2 8.1.2 X
st
5.3.2.2.3 8.2.3.1 1 part X
5.3.2.2.4 8.2.5 (2) X
5.3.2.2.5 8.2.3.2 X
5.3.2.2.6 8.2.3.3 X
5.3.2.2.7 8.2.3.4 X
5.3.2.2.8 8.2.3.5 X
5.3.2.2.9 8.2.3.6 X

15
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 2 (continued)

Unchanged

Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

5.3.2.3.1 8.2.4.1 X
5.3.2.3.2 8.2.4.2 X
5.3.2.3.3 8.2.4.3 X
5.3.2.3.4 8.2.4.4 X
5.3.2.3.5 8.2.4.5 X
5.3.3.1 (1,2,4) 8.2.1 (1) X Requirement for life cycle, torsional effects and
assembled steps and pallets introduced
5.3.3.1 (3) 8.2.1 (2) X
5.3.3.2.1 8.2.2.1.1 X
5.3.3.2.2 8.2.5 (1) X New strength requirements
5.3.3.2.3 8.2.2.1.2 X
5.3.3.2.4 8.2.4.6.1.1 X
5.3.3.3.1.1 (1,2,4) 8.2.2.2.1 X
5.3.3.3.1.1 (3) - X Requirements for components parts added
5.3.3.3.1.2 - X Requirement for torsional test
5.3.3.3.2.1 8.2.2.2.2 X
(1,2,3,5)
5.3.3.3.2.1 (4) - X Requirements for components parts added
5.3.3.3.2.2 - X Requirement for torsional test
5.3.4 (1) 10.2.1 (1) X Maximum dimensions are defined.
5.3.4 (2) 10.2.1 (2) X
5.3.4 (3) 8.2.4.6.1.2 X
5.3.5 (1,3) 11.1 X
5.3.5 (2) - X Requirement for demarcation
5.3.6 - X Requirement for detection of missing step/pallet
5.4.1.1 12.1 X
5.4.1.2.1 12.2.3 X Defines the limits for nominal speed; the term
"rated speed" is no longer used in EN 115-1.
5.4.1.2.2 12.2.1 X
5.4.1.2.3 (1) 12.2.2 X
5.4.1.2.3 (2) 12.2.2.1 X
5.4.1.2.3 (3) 12.2.2.2 X
5.4.1.3.1 12.3.1 X
5.4.1.3.2 12.3.2 X Defines more clearly safety factors for all drives
5.4.1.4 (1,3) 12.7 (1,3) X

16
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 2 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

- 12.7 (2) X
5.4.1.4 (2) - X Requirement for electric safety device
5.4.1.5 12.8 X
5.4.2.1.1.1 (1) 12.4.1 X
5.4.2.1.1.1 (2) - X Excess stopping distance failure lock requirement
5.4.2.1.1.1 (3) - X Requirement for brake lift monitoring
5.4.2.1.1.2 12.4.1.1 X
5.4.2.1.1.3 12.4.1.2 X
5.4.2.1.1.4 12.4.3 X
5.4.2.1.2 (1,3) 12.4.2 (1,3) X
5.4.2.1.2 (2) 12.4.2 (2) X Deletes the requirement for brake force to be
generated by weights
5.4.2.1.3.1 12.4.4.1 X
5.4.2.1.3.2 (1,2,3) 12.4.4.2 X
5.4.2.1.3.2 (4) - X Specifies maximum deceleration rate
5.4.2.1.3.3 12.4.4.3 X Improvement of wording
5.4.2.1.3.4 12.4.4.4 (1,2,3,5) X
(1,2,3,5)
- 12.4.4.4 (4) X Replaced by the note in 5.4.2.1.3.4
5.4.2.1.3.4 (4) - X Specifies maximum deceleration rate
5.4.2.2.1 12.6.1 X Improved wording
5.4.2.2.2 (1) 12.6.2 X Deceleration requirement added
5.4.2.2.2 (2) 12.6.6 X
5.4.2.2.3 12.6.3 X
5.4.2.2.4 12.6.4 X
5.4.2.2.5 12.6.5 X
nd
5.4.2.3.1 12.5.1 X Generalisation of 2 paragraph
5.4.2.3.2 12.5.2 X
5.4.3.1 9.1.1 X
5.4.3.2 (1) - X Fatigue life requirement
st
5.4.3.2 (2) ex 1 9.1.2 (2) X New material specifications and tensile test
sentence
5.4.3.2 (2) 9.1.2 (1) X
st
1 sentence
5.4.3.2 (3) 9.1.2 (3) X
5.4.3.3 9.1.3 X Criteria for tensioning device movement

17
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 2 (continued)

Unchanged

Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

5.4.4.1 9.2.1 X Requires worst case calculation for force


5.4.4.2 9.2.2 X
- 9.3 X
5.5.1 5.1.5.1 X Definitions shifted to Clause 3
5.5.2.1 7.6 X
5.5.2.2 (1) 5.1.5.2 (1) X
5.5.2.2 (ex 1) 5.1.5.2 (2) X Now contains specific dimensions and design
requirements
5.5.2.3 5.1.5.3 X Additional requirement for lateral force added
5.5.2.4 (1,2,3,4) 5.1.5.4 (1,2,3,4) X
5.5.2.4 (5) 5.1.5.4 (5) X Absolute requirement for toughened glass and
requirements for multi-layer glass defined
- 5.1.5.5 X Specific information given in other clause
5.5.2.5 5.1.5.8 X
st
5.5.2.6, 1 5.1.5.7 X
sentence
nd
5.5.2.6, 2 5.1.5.7.1 (1) X
sentence
5.5.2.6.1 5.1.5.7.1 (2) X
5.5.2.6.2 5.1.5.7.2 X
5.5.3.1 Note 5.1.5.6.1 X
5.5.3.1 5.1.5.6 X
5.5.3.2
5.5.3.3 5.1.5.6.2 X
5.5.3.4 a) b) c) 5.1.5.6.3 a) b) d) X
5.5.3.4 d) 5.1.5.6.3 c) X Now includes specific values for coefficient of
friction
5.5.4.1 5.1.5.9 X
5.5.4.2 7.2 X
5.5.5.1 11.2.1 X
5.5.5.2 11.2.2 X
5.6.1 (1) 7.1 X
5.6.1 (2) - X Requirement on handrail speed monitoring
- 7.8 X Requirement not necessary because of handrail
monitoring (see 5.6.1)
5.6.2.1 7.3.1 (1) (2) X

18
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 2 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

5.6.2.2 7.3.2 X
5.6.2.3 7.3.3 X
5.6.3 7.4 X
5.6.4.1 7.5.1 X
5.6.4.2 7.5.2 X Additional requirement to reduce risk of trapping
between handrail and floor plate
5.6.4.3 7.5.3 X
5.6.5 7.7 X
5.7.1 5.2.2 X Now includes definitions for materials and test
methods for anti-slip properties (Annex J)
5.7.2.1 (1) 10.1.3 (1) X
5.7.2.1 (2,3) 10.1.3 (3) X Upper limit and speed amended
5.7.2.1 (3) Annex D.1 X Requirement now defined
5.7.2.1 (4) 10.1.3 (2) X
5.7.2.2 10.1.4 X Intermediate speed radius of curvature included
Annex D.2 for upper transition and lower transition radius of
curvature above 0,65 m/s
5.7.2.3 10.1.5 X
5.7.2.4 10.1.6 X
5.7.2.5 (1,2) 10.2.2 X
5.7.2.5 (3) 14.2.2.4.1.l) X Now defined more clearly in the text
st
5.7.3.1 1 8.3.1 X
sentence
nd
5.7.3.1 2 8.3.2.4 (2) X
sentence
5.7.3.2.1 8.3.2.1 X
5.7.3.2.2 8.3.2.2 X
5.7.3.2.3 8.3.2.3 X Maximum angle reduced to 35°
5.7.3.2.4 8.3.2.4 (1) X
5.7.3.2.5 8.3.2.5 X Common requirement for all types of machine
5.7.3.2.6 8.3.2.6 X Improved wording
5.7.3.3.1 11.3.1 X Standardisation of mesh depth for steps, pallets
and belts
5.7.3.3.1 11.4.1 X
5.7.3.3.2 11.3.2 X
11.4.2
5.8.1 (1,2) 6.1 (ex 1) X

19
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 2 (continued)

Unchanged

Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

5.8.1 (3) 12.9 X


5.8.2.1 6.3.1.1 X
5.8.2.2 - X Requirement for lifting attachments
5.8.2.3 6.3.1.2 X
5.8.3.1 6.3.2 (2) X
st
1 sentence
5.8.3.1 13.6.1 X
nd
2 sentence
5.8.3.2 (1) 6.3.2 (1) X
nd rd
2 and 3
sentence
5.8.3.2 (2) - X Requirement for lighting level
5.8.3.3 13.6.2 X
5.8.4 6.3.3 X
5.9 0.5.1 X Specified characteristics included
5.10 5.5 X
5.11.1.1 13.1 X
5.11.1.2.1 13.1.1.1 X
5.11.1.2.2 13.1.1.2 X
5.11.1.2.3 Annex A.4.3 X Requirements now defined by EN 12015 and
EN 12016
5.11.1.3 13.1.2 X Specified now by EN 60204-1
5.11.1.4 13.1.3 X Specified now by EN 60204-1
5.11.1.5 13.1.4 X
5.11.1.6 13.1.5 X Specified now by EN 60204-1
5.11.2 13.2. X
5.11.3 13.3 X
5.11.4 13.4 X

5.11.5.1 13.5.1 X
5.11.5.2 13.5.2 X
5.11.5.3.1 13.5.3.1 X
- 13.5.3.2 X Covered by 5.11.1.2
5.11.5.3.2 13.5.3.3 X
5.11.5.3.3 13.5.3.4 X
- 13.5.3.5 X Covered by EN 60204-1
5.11.5.4 13.5.4 X

20
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 2 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

5.11.6 13.7
5.11.7 - X Requirement for protection against electrostatic
loading
5.12.1.1.1 14.1.1 X
5.12.1.1.2 14.1.1.1 X Requirement to consider phase reversal fault
5.12.1.1.3 14.1.1.2 X
5.12.1.1.4 14.1.1.3 X
5.12.1.2.1.1 14.1.2.1.1 X
5.12.1.2.1.2 14.1.2.1.2 X Defines exceptions
5.12.1.2.1.3 14.1.2.1.3 X
5.12.1.2.1.4 14.1.2.1.4 X
- 14.1.2.1.5 X Covered by requirements in Annex B
- 14.1.2.1.6 X Replaced by the requirements in 5.12.1.2.1.1
5.12.1.2.1.5 14.1.2.1.7 X
5.12.1.2.2 14.1.2.2 X
5.12.1.2.3 14.1.2.3 X
5.12.1.2.4 14.1.2.4 (1) X
- 14.1.2.4 (2,3) X 5.12.1.2.1.1 defines how safety switches and
safety circuits shall operate.
5.12.1.2.5 14.1.2.5 X Test requirements moved to D.3.1 and D.3.2
5.12.2.1.1 (1) 14.2.1 X
5.12.2.1.1 (2) - X Clarification from 14.1.1
5.12.2.1.1 (3,4) - X New requirement for remote starting
5.12.2.1.2 14.2.1.1 X New requirements for entering speed and
acceleration rate
5.12.2.1.3 14.2.1.2 X
5.12.2.2.1 14.2.2.1 X
5.12.2.2.2 14.2.2.2 X
5.12.2.2.3.1 14.2.2.3.1 X Positioning for stop switches for emergency
situations modified
5.12.2.2.3.2 14.2.2.3.2 X
5.12.2.2.4.1 14.2.2.4.1 X Additional requirements in Table 6
5.12.2.2.4.2 14.2.2.4.2 X
5.12.2.2.4.3 - X This requirement was previously identified in A.3
which was only informative.
5.12.2.3 14.2.3 X

21
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 2 (continued)

Unchanged

Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

5.12.2.4.1 14.2.4.1 X Restarting conditions revised in accordance with


Table 6
5.12.2.4.2 14.2.4.2 X Design solutions removed
5.12.2.5.1 14.2.5.1. X
5.12.2.5.2 14.2.5.2 X
5.12.2.5.3 14.2.5.3 X Additional requirements for stop switch defined
5.12.2.5.4 14.2.5.4 X Specific reference to items in Table 6
6 - X Provides indications of methods to verify
conformity
7.2.1.1 15.1.1 X
7.2.1.2.1 15.1.2.1 X Prohibition sign for push chairs; old Figure 7 not
necessary because of deflector devices.
Additional guidance regarding local conditions.
7.2.1.2.2 15.1.2.2 X
7.2.1.2.3 15.1.2.3 X
7.2.1.3 15.1.3 X
7.2.1.4 15.1.4 X
7.2.2 15.2 X
- 16.1 X Operational requirement deleted
7.3 16.2 X Former 16.2.1.1.1 and 16.2.1.1.2 covered by
verification (Clause 6)
7.4 (ex e) 16.3 X More detailed in EN 115-1
7.4 e) 16.4 X More detailed in EN 115-1
7.5 15.1.5 X
Annex A.1 - X Required by structure according EN 414
Annex A.2.1 5.2.3 X
Annex A.2.2 7.3.1 (3) X Requirement for vertical distance b12 defined
Annex A.2.3 7.3.1 (4) X Minimum distance increased to 160 mm
Annex A.2.4 5.2.4 X Reference point for b9 changed to outer edge
Annex A.2.5 5.2.1 (1) X
Annex A.2.6 5.2.1 (2) X
Annex A.2.7 - X Requirement for protection against falling from
the landing
Annex A.2.8 5.4.1 X
Annex A.2.9 5.4.2 X All lighting levels defined as 50 lx
Annex A.3.1 6.2.1 (1) X

22
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Table 2 (continued)

Unchanged
Modified

Deleted
EN 115:1995
EN 115-1:

New
+A1:1998 Remarks
2008
+A2:2004

Annex A.3.2 6.1 X Requirement for machinery space access to be


lockable
Annex A.3.3 6.3.2 (1) X Requirements for lighting levels
st
1 sentence
Annex A.3.4 - X Requirement for emergency lighting
Annex A.3.5 6.3.1.3 ex c) X
Annex A.3.6 (1) 6.2.1 (2) X
Annex A.3.6 (2) 6.3.1.3 c) X
- 6.2.2 X
Annex A.3.7 6.3.1.4 X
Annex A.4 - X Provides details of electric supply and protection
requirements
Annex B.1 Annex A.1 X
Annex B.2 Annex A.2 X
Annex C Annex B X
Annex D.2 - X General provisions added
Annex D.3 - X Test samples requirements added
Annex D.4 Annex A.4.1 X
Annex D.5 Annex A.4.2 X
Annex E Annex A.3 X
Annex F - X Informative annex
Annex G - X New safety signs
Annex H.1 3.8 X Maximum capacities defined (modified to reflect
achievable carrying capacity)
Annex H.2 (1) Annex D.3 X
Annex I 0.5.3 X Restrictions of the use of shopping trolleys and
baggage carts
Annex J - X Information on determining ant-slip properties
Annex K - X Information on determining friction coefficients
Annex L - X Interpretation sheet

23
PD CEN/TR 115-3:2009
CEN/TR 115-3:2009 (E)

Bibliography

[1] EN 115:1995, Safety rules for the construction and installation of escalators and passenger conveyors

[2] EN 115-1:2008, Safety of escalators and moving walks – Part 1: Construction and installation

[3] EN 414, Safety of machinery – Rules for the drafting and presentation of safety standards

[4] EN 12015, Electromagnetic compatibility – Product family standard for lifts, escalators and moving
walks – Emission

[5] EN 12016, Electromagnetic compatibility – Product family standard for lifts, escalators and moving
walks – Immunity

[6] EN 60204-1, Safety of machinery – Electrical equipment of machines – Part 1: General requirements
(IEC 60204-1:2005, modified)

24
PD CEN/TR 115-3:2009

This page has been intentionally left blank


PD CEN/TR
115-3:2009
BSI - British Standards Institution
BSI is the independent national body responsible for preparing British
Standards. It presents the UK view on standards in Europe and at the
international level. It is incorporated by Royal Charter.
Revisions
British Standards are updated by amendment or revision. Users of British
Standards should make sure that they possess the latest amendments or
editions.
It is the constant aim of BSI to improve the quality of our products and services.
We would be grateful if anyone finding an inaccuracy or ambiguity while using
this British Standard would inform the Secretary of the technical committee
responsible, the identity of which can be found on the inside front cover. Tel:
+44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.
BSI offers members an individual updating service called PLUS which ensures
that subscribers automatically receive the latest editions of standards.
Buying standards
Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996
7001 Email: orders@bsigroup.com You may also buy directly using a debit/credit
card from the BSI Shop on the Website http://www.bsigroup.com/shop
In response to orders for international standards, it is BSI policy to supply the
BSI implementation of those that have been published as British Standards,
unless otherwise requested.
Information on standards
BSI provides a wide range of information on national, European and
international standards through its Library and its Technical Help to Exporters
Service. Various BSI electronic information services are also available which
give details on all its products and services. Contact Information Centre. Tel:
+44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: info@bsigroup.com
Subscribing members of BSI are kept up to date with standards developments
and receive substantial discounts on the purchase price of standards. For details
of these and other benefits contact Membership Administration. Tel: +44 (0)20
8996 7002 Fax: +44 (0)20 8996 7001 Email: membership@bsigroup.com
Information regarding online access to British Standards via British Standards
Online can be found at http://www.bsigroup.com/BSOL
Further information about BSI is available on the BSI website at http://
www.bsigroup.com.
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may
be reproduced, stored in a retrieval system or transmitted in any form or by any
means – electronic, photocopying, recording or otherwise – without prior written
BSI Group permission from BSI.
Headquarters 389 This does not preclude the free use, in the course of implementing the standard,
Chiswick High Road, of necessary details such as symbols, and size, type or grade designations. If
London, W4 4AL, UK these details are to be used for any other purpose than implementation then the
Tel +44 (0)20 8996 9001 prior written permission of BSI must be obtained.
Fax +44 (0)20 8996 7001
www.bsigroup.com/ Details and advice can be obtained from the Copyright and Licensing Manager.
standards Tel: +44 (0)20 8996 7070 Email: copyright@bsigroup.com

You might also like