DIRECT MOUNT ACTUATOR VALVES
GENERAL DESCRIPTION
The Versa NAMUR mount control valves are high flow, bubbletight, C5 and the C316 are bubbletight, high flow, 5-port, solenoid/pilot
and designed to mount directly to any NAMUR actuator, thus reduc- type valves. This design assures a positive shift when the valve is
ing actuator response time and space. Installed costs are also low- energized and reduces the chance of coil burnout. Manual override
er as the need for tubing, fittings, brackets and assembly labor are for single or double solenoid valves are available as an option.
greatly reduced. All mounting screws and seals are included with the The Versa E5 NAMUR is a 3-way direct-acting solenoid valve.
valve. There are two types of valves, direct acting and pilot operated; A complete selection of electrical connections, area classifications,
materials are aluminum or stainless steel. and power requirements makes the most exacting and demanding
specifications or applications easy to satisfy. See page 4.
NAMUR ReBreather
Introduction Low profile design (cont.)
The Versa ReBreather block, an add on accessory, is designed to speed control is offered. The material of the main plate is engineered
protect the spring chamber of a spring return rack and pinion actuator polymer. All fasteners and speed controls are 316 stainless steel for
from external airborne contaminants, by introducing clean exhaust air
enhanced corrosion protection and product life.
into the spring chamber during the return stroke.
Options
How it works. Basic plate is supplied with a ¼” npt vent port. Versa offers a dust
With the ReBreather block attached to the exhaust screen (MFS) in dusty environments or in areas
ports of the NAMUR valve, the actuator piston side where moisture may be present, the ReBreather
air volume is redirected to the spring chamber of
is available with a positive check (DE).
the actuator. As the springs begin to push the
pistons, a low pressure area develops in the Typical Circuit
spring chamber, which draws in the air being Actuator,
exhausted from the piston chamber creating a Spring Return
positive pressure. No additional air is required
to complete the cycle and prevent contamination.
The ReBreather lives up to it’s name by reusing clean C Series 3-way
B A NAMUR Valve
exhausted air to maintain a dirt and dust free actuator spring
chamber, extending life and reliability of the actuator and valve.
2 www.versa-valves.com
SPECIFICATIONS
MATERIALS Temperature:
C5 & E5: Ambient and media range
Actuating Caps Valve Seals Solenoid Parts
Valve Sleeve, 5°F to 125°F (-15°C to 50°C).
Series Plunger Valve to C316: Ambient and media range
Body Solenoid Spring Plunger Body Actuator Plunger
& Spring -5°F to 200°F (-20°C to 93°C)
NBR -55°F to 200°F (-48°C to 93°C)
E5 — — — (Nitrile) — NBR
Anodized (Low temp option -44)
Aluminum Anodized Anodized Synthetic FKM (Nitrile) 304, 430F & 302
C5 Aluminum Aluminum Resin (Fluorocarbon) Flow Rate:
Stainless Steel
316L 316L 316L 316L E5: Cv = 0.08
C316 Stainless Stainless Stainless Stainless FKM (Fluorocarbon) C5: Cv = 0.75
Steel Steel Steel Steel
C316: Cv = 1.6
PRESSURES & WEIGHTS
Operating Approximate Weights
Valve
Function Pressure Range Ordinary Hazardous Service
Series
Pneumatic Service XISC, XISX6 -XX, -XN, -XIS_ -XMA_, -XIF_ XDB_
E5 0-150 psi (0-10.3 bar) 0.6 lbs (272 g) 0.5 lbs (227 g) 0.9 lbs (408 g) — —
C5 Single Solenoid/spring return (2-position) 15-115 ps (1-8 bar) 0.8 lbs. (363 g) 0.7 lbs (318 g) 1.1 lbs. (500 g) — —
C316 25-150 psi (1.8-10.3 bar)* 1.5 lbs (680 g) 1.5 lbs (680 g) 1.7 lbs (771 g) 2.3 lbs (1043 g) 2.5 lbs (1134 g)
C5 10-115 ps (0.7-8 bar) 1.5 lbs (545 g) 1.7 lbs (771 g) 1.8 lbs. (816 g) — —
Double Solenoid/detented (2-position)
C316 15-150 psi (1-10.3 bar)* 2.2 lbs (998 g) 2.2 lbs (998 g) 2.6 lbs (1179 g) 3.8 lbs (1724 g) 4.3 lbs (1950 g)
C5 Double Solenoid/spring centered (3-position) 15-115 ps (1-8 bar) 1.2 lbs. (545 g) 1.4 lbs (635 g) 1.8 lbs. (816 g) — —
*for applications above 125 psi (8.6 bar) exhaust flow controls or mufflers are recommended
IN EX
E5SM-3011-34-NB1-†-(coil code) *All valves include O ring interface seals and #10-24 mounting screws.
3-Way 1/4 NPT
E5 .08 † Add suffix option here if required, For coil code see page 4.
3/2 E5 & C5: For #10-32 screws change NB1 to NB2. For M5 screws change NB1 to NB3.
C316 NUMAR: For #10-32 screws change NE1 to NE2. For M5 screws change NE1 to NE3.
3-way is the same valve as 4-way, but is provided with a relocated cylinder port plug. See note on page 7.
ReBreather SELECTOR
On a valve As a kit
Suffix* Description C Series C-316 Series Description
-RB Plate, ¼” npt vent port open C-33RB-NB C-33RB-NE Plate, ¼” npt vent port open
Plate and speed control with ¼” npt
-RB1 Plate and speed control, with ¼” npt vent port open C-33RB-NB-BC C-33RB-NE-BC vent port open
-RB2 Plate with DE-3 in vent port** C-33RB-NB-DE3 C-33RB-NE-DE3 Plate with DE-3 in vent port**
Plate and speed control with DE-3
-RB3 Plate and speed control with DE-3 in vent port C-33RB-NB-BC-DE3 C-33RB-NE-BC-DE3 in vent port
-RB4 Plate and with MFS-3 in vent port C-33RB-NB-MFS3 C-33RB-NE-MFS3 Plate and with MFS-3 in vent port
Plate and speed control with MFS-3
-RB5 Plate and speed control with MFS-3 in vent port C-33RB-NB-BC-MFS3 C-33RB-NE-BC-MFS3 in vent port
*Add suffix to complete C/C316 series valve part number. **Aluminum DE on C Series and Stainless on C-316 Series
Actuator Speed ACTUATOR VOLUME in3 (cm3) For double-acting actuators (open & close), use
Valve 5 10 25 50 100 150 200 400 600 1000 volumes from selected actuator specifications and the
Type (82) (162) (410) (820) (1641) (2460) (3280) (6560) (9840) (16400) chart for estimated speed. The times indicated are per
Actuator Cycle C5/C316 .32 .36 .47 .63 .98 1.3 1.7 3.1 4.5 7.2 shift. For spring return actuators, use open volume to
time in seconds E5 .46 .64 1.1 2.0 3.9 5.7 7.5 — — — obtain time from chart. Actuator spring loading may
affect shift time.
The above chart represents approximate actuator operation times under average load conditions at 80 psi Slower speeds (adjustable) can always be
(5.5 bar). Due to differing designs of quarter-turn actuators, breakaway friction, loading, internal airflow, inlet accomplished by using Versa’s Bleed Control Valves
piping, fittings and exhaust port options, the values shown are intended as an estimate. Faster or slower times
in the control valve exhaust port.
may actually be achieved.
www.versa-valves.com 3
ELECTRICAL
-HC NEMA 4;
General Purpose Indoor & Outdoor CSA
-HCC (Shown) IP65
-XX
CLASS I, DIV. 2 (A & B)
Hazardous CLASS I, DIV. 1 (C & D) UL - CSA NEMA 7 & 9
Locations CLASS II, DIV. 1 (E, F & G)
-LB-XX
-XN
Ex d IIB+H2 T3 to T6 Gb IECEx
(d) Flameproof IP65 & IP66
II 2 G Ex d IIB+H2 T3 to T6 IECEx ATEX
-LB-XN
EX II 2 G D ATEX
Ex d e IIC T* Gb IECEx -INMETRO
EX tb IIIC T* ºC Db
-XDBS* (d) Flameproof IP66, IP67,
(e) Increased Safety Class I Div I Grp B, C & D CSA & IP68
-XDBT*
Class I Div II Grp E, F & G
For coil housing clearance -U suffix EX d IIC DIP A21 T6 T4
suggested. See page 6 for recom-
mended options
OPTIONS
Solenoid Vent Options
4 www.versa-valves.com
ELECTRICAL
PRODUCT NUMBER COIL CODES: Complete product numbers require, when applicable, a coil code that represents the desired coil current type, frequency and
voltage. The coil code takes the form shown below, with ratings and voltage substituted as required.
Rating Code Voltage
A = 60Hz frequency Indicated by three digits:
D = Direct Current (DC) e.g. 24 volts = 024
E = 50Hz frequency 120 volts = 120.
A120 = AC,120Volts/60hz
Voltage Electrical
(Power) Characteristics Miscellaneous
All usual 50 Hz & 60 Hz AC (6W) Steel cover with 1/2 NPT conduit entry.
All usual DC (7W)
24V60, 120V60, 240V60 (8.5W) Mini DIN socket with PG9 cable gland (-HC) or 1/2” conduit
24V50, 110V50, 220V50 (8.5W) Class F epoxy molded coil (155ºC). connection (-HCC).
12VDC, 24VDC, 48VDC (10.5W) Continuous duty, 2 leads 24” (60 cm).
24V60, 120V60, 240V60 (8.5W) Epoxy encapsulated coil with, steel, 1/2 NPT conduit entry.
24V50, 110V50, 220V50 (8.5W)
12VDC, 24VDC, 48VDC (10.5W
Voltage Electrical
(Power) Characteristics Miscellaneous
Steel, Electroless Nickel plated coil housing with 1/2 NPT
All usual 50 Hz & 60 Hz AC (5.6W) conduit entry.
All usual DC (7.2W) For options see page 6
12V60, 24V60, 48V60, 120V60, Steel, Electroless Nickel plated coil housing
240V60 (1.8W) with 1/2 NPT conduit entry.
6VDC, 12VDC, 24VDC, 48VDC For options see page 6
Maximum pilot pressure 120 psi (8 bar).
(1.8W) 1.8W nominal power.
Class F epoxy molded coil (155ºC).
Continuous duty. Steel, Electroless Nickel plated coil housing
All usual 50 Hz & 60 Hz AC (5.6W) 3 leads 24” (60 cm). with M20 x 1.5 conduit entry.
All usual DC (7.2W) Ground terminal on cover.
For options see page 6
Steel, Electroless Nickel plated coil housing
12V60, 24V60, 48V60, 120V60, with M20 x 1.5 conduit entry.
240V60 (1.8W) Ground terminal on cover.
6VDC, 12VDC, 24VDC, 48VDC For options see page 6
(1.8W) Maximum pilot pressure 120 psi (8 bar)
1.8W nominal power.
Stainless steel coil housing with Suffix Detail Ordering Code
internal Junction Box. Internal M 20 Connection ½” Connection
24VDC (D024) and external ground screw.
120V60 (A120) 110V50 (E110) No Diode Diode No Diode Diode
230V50 (E230) Epoxy molded coils rated for Standard (vent to atmosphere) XDBS1 XDBS5 XDBT1 XDBT5
continuous duty, Class H, 180°C.
1.8 Watt standard, for lower watt 1/8” Adapter (-H2E) XDBS2 XDBS6 XDBT2 XDBT6
contact factory. 1/4” Adapter (-HE) XDBS3 XDBS7 XDBT3 XDBT7
Dust Nut (-L14) XDBS4 XDBS8 XDBT4 XDBT8
Requires the use of an approved barrier or isolator.
Maximum operating system voltage before barrier 28VDC.
24VDC Class F epoxy molded coil (155ºC). Maximum pilot pressure 115 psi (8 bar).
system voltage prior to barrier Continuous duty. 3 spade terminals & DIN connector with PG9
(1.6 watt max.) cable gland: (-HC)
1/2 NPT conduit entry: (-HCC)
Options
Overrides Solenoid Orientation
C5 Valves* C316 Valves C316 Valves
Certification/Power
6 www.versa-valves.com
DIRECT MOUNT ACTUATOR VALVES
DIMENSIONS
Series C5 Series E5
B
END VIEW 1/4” NPT (G1/4)
B A C TOP VIEW VENT PORT
C 50 VENT
SIDE VIEW (CGS) NOTE:
The function of the valve is field convertible.
When ordering a 4 way, CGS-4232-NB1 B
C the plug is in position “4” (as shown).
when ordering a 3-way, CGS-3232-NB1
the plug isin position “3.”
Exhaust “B” becomes a vent when used A
1/4” NPT (G1/4)
1/4” NPT (G1/4) as a 3-way. INLET PORT
A
SIDE VIEW (CGG/CXX)
Series C316
Typical CGS-4332-316-NE1-XMA_-A120 Typical CGS-4332-316-NE1-U-XDB_-A120
Typical CSG-4332-316-NE1-XX-A120 Top View Top View
Top View
ERSA ®
PARAMUS NJ 07652 U.S.A.
B
B B
A A
Side View Typical CGG-4332-316-NE1-U-XDB_-A120
C Side View
Typical CGG-4332-316-NE1-XMA_-A120
Side View
A
C
Typical CGG-4332-316-NE1-XX-A120 C
Side View
A A
INCHES
DIMENSIONS (mm)
Solenoid Options
VALVE General Service Hazardous Location
Function
SERIES Standard, -228L -027, 043 C50, -PC -XX, -XN -XISC, -XISX6 -XMA_, XIF_ -XDB_
A B C A B C A B C A B C A B C A B C A B C
Single solenoid, 2.11 1.75 2.31 2.84 1.75 2.31 3.01 2.47 2.39 2.8 1.89 1.75
E5 spring return (53.6) (44) (58.7) — — — — — — — — —
(204.9) (44) (58.7) (76.5) (62.7) (60.7) (71) (48.2) (44)
5.02 1.56 1.29 3.45 1.56 2.34 5.02 1.04 2.09 3.79 1.31 1.45 3.53 1.31 1.15
C5 Single solenoid, (127.5) (39.6) — — — — — —
(32.8) (87.6) (39.6) (59.4) (127.5) (26.4) (53.1) (96.3) (33.3) (36.8) (89.7) (33.3) (29.2)
spring return
C316 3-Way or 4-Way 5.56 1.63 2.15 — — — 5.56 1.63 2.15 5.56 1.63 2.32 5.43 1.63 2.94 6.59 2.56 4.13 4.63 2.50 4.74
(141.3) (41.3) (54.7) (141.3) (41.3) (54.7) (141.3) (41.3)) (59) (138) (41.3) (74.6) (167.3) (65) (104.8) (117.6) (63.5) (120.3)
Double 7.92 1.56 2.04 7.42 1.56 2.34 7.93 1.56 2.09 8.07 1.56 2.26 7.55 1.56 6.93
C5 — — — — — —
solenoid (201.1) (39.6) (51.8) (188.4) (39.6) (59.4) (201.4) (39.6) (53) (205) (39.6) (57.4) (191.7) (39.6) (176)
3-Way or 5.56 1.63 2.15 8.57 1.63 2.15 8.78 1.63 2.32 8.31 1.63 2.94 10.8 2.56 4.13 6.32 2.50 4.74
C316 4-Way — — —
(141.3) (41.3) (54.7) (217.7) (41.3) (54.6) (223.1) (41.3) (59) (211.1) (41.3) (74.6) (275) (65) (104.8) (160.5) (63.5) (120.3)
For warranty information and/or any additional information with regards to installation, operation and service warnings, please consult factory.
www.versa-valves.com 7
Versa
has been
supplying the
oil and gas
industr y with
pneumatic
and hydraulic
components
for over 50
years. We
have built a
reputation
for quality
that is
unsur passed
in the market
for high
perfor mance
solenoids,
pneumatic
relays, resets
and pilot
valves
The warnings below must be read and reviewed before designing a system utilizing,
installing, servicing, or removing a Versa product. Improper use, installation or servicing of LIMITED WARRANTY DISCLAIMER
a Versa product could create a hazard to personnel and property. AND LIMITATION OF REMEDIES
DESIGN APPLICATION WARNINGS Versa’s Series products are warranted
Versa products are intended for use where compressed air or industrial hydraulic fluids are to be free from defective material and
present. For use with media other than specified or for non-industrial applications or other workmanship for a period of ten years
applications not within published specifications, consult Versa. from the date of manufacture, provided
Versa products are not inherently dangerous. They are only a component of a larger said products are used in accordance
system. The system in which a Versa product is used must include adequate safeguards with Versa specifications. Versa’s
to prevent injury or damage in the event of system or product failure, whether this failure liability pursuant to that warranty
be of switches, regulators, cylinders, valves or any other system component. System is limited to the replacement of the
designers must provide adequate warnings for each system in which a Versa product
is utilized. These warnings, including those set forth herein, should be provided by the Versa product proved to be defective
designer to those who will come in contact with the system. provided the allegedly defective
product is returned to Versa or its
Where questions exist regarding the applicability of a Versa product to a given use, inquiries authorized distributor. Versa provides
should be addressed directly to the manufacturer. Confirmation should be obtained directly
from the manufacturer regarding any questioned application prior to proceeding. no other warranties, expressed or
implied, except as stated above.
INSTALLATION, OPERATION AND SERVICE WARNINGS There are no implied warranties
Do not install or service any Versa product on a system or machine without first of merchantability or fitness for a
depressurizing the system and turning off any air, fluid, or electricity to the system or
machine. All applicable electrical, mechanical, and safety codes, as well as applicable particular purpose. Versa’s liability for
governmental regulations and laws must be complied with when installing or servicing a breach of warranty as herein stated is
Versa product. the only and exclusive remedy and in
no event shall Versa be responsible or
Versa products should only be installed or serviced by qualified, knowledgeable personnel
who understand how these specific products are to be installed and operated. The liable for incidental or consequential
individual must be familiar with the particular specifications, including specifications for damages.
temperature, pressure, lubrication, environment and filtration for the Versa product which
is being installed or serviced. Specifications may be obtained upon request directly from
Versa. If damages should occur to a Versa product, do not Operate the system containing
the Versa product. Consult Versa for technical information.