You are on page 1of 36

Bulletin: V-316

2017

V-316 SERIES

Versa Products Company, Inc., 22 Spring Valley Road, Paramus, NJ 07652 USA Phone: (201) 843-2400 Fax: (201) 843-2931
Versa BV, Prins Willem Alexanderlaan 1427, 7312 GB Apeldoorn, The Netherlands Phone: +31-55-368-1900 Fax: +31-55-368-1909
E-mail: sales@versa-valves.com www.versa-valves.com
QUICK INDEX

VALVES/ACTUATORS Section Page


Three-Way Valves ........................................................................................... general V 3-WAY 14 - 15

..................................................................................... dimensions V 3-WAY 16 -19

Four-Way Valves ........................................................................................... general V 4-WAY 20 - 21

..................................................................................... dimensions V 4-WAY 22 - 25

Actuating Devices .......................................................................................................................................... 10 - 13

ByPass Valve ................................................................................................................................................. 32

Latching-Manual Reset Valves ...................................................................................................................... 30 - 31

Lockout Valves ............................................................................................................................................... 33

Special Purpose Dual Solenoid Valves .......................................................................................................... 28 - 29

VMAP ............................................................................................................................................................ 34

SPECIFICATIONS
Basic Features ............................................................................................................................................... 3

Construction ................................................................................................................................................... 6

Electrical ......................................................................................................................................................... 7 -9

Electrical Combination Suffix Details (Cross Reference) ................................................................................ 35

Filtration ......................................................................................................................................................... 6

Flow (Cv) ................................................................................................................................................... 7

Port Sizes ....................................................................................................................................................... 6

Pressure Ranges ........................................................................................................................................... 6

Product Numbering System ........................................................................................................................... 4-5

Seals .............................................................................................................................................................. 6

Temperature ................................................................................................................................................... 6

Stainless Steel Tags ....................................................................................................................................... 13

PARTS
Combination Actuators ................................................................................................................................... 26 - 27

WARNINGS & WARRANTY ..................................................................................................................... Back Cover


12417

2 www.versa-valves.com
BASIC FEATURES
Versa exercises diligence to assure that information contained in this catalog is correct, but does not ac-
cept responsibility for any errors or omissions. Versa also reserves the right to change or delete data or
products at any time without prior notification. To be sure the data you require is correct, consult factory.

GENERAL CHARACTERISTICS OF SERIES “V-316” VALVES


The V-316 Valve Series provides a full range of control valves suited to the most demanding of applications. Ruggedly
constructed, both internally and externally, of stainless steel, these valves are able to withstand the physical abuse
of corrosive environments and controlled media.
A modular design concept utilizing three basic sub-assemblies: a Body Assembly and two Actuator Assemblies
(active or passive), simplifies circuit planning while affording almost unlimited combination possibilities.
Port sizes are 1/4”, 3/8”, and 1/2” NPT in 2 and 3-position, three-way (3/2, 3/3), and four-way (5/2 and 5/3) styles. A
1” NPT is available as 2-position, three-way (3/2) and four-way (5/2).
Actuation types include manual (hand lever, palm button, latching detent & manual reset), pilot (pressure pilot,
diaphragm pilot, “air-latch” pilot), and solenoid-pilot (including several approved hazardous service types).

CONSTRUCTION
ISO 9001
High Performance Solenoid
Near frictionless direct acting poppet design
yields positive shifting and the lowest solenoid Solenoid-Pilot Design
power/wattage ratings. Epoxy encapsulated Direct acting valve integrated on pilot valve
coils with high heat class ratings are standard The V-316 Series solenoid valve utilizes a high CERTIFIED
for moisture resistance, heat dissipation and performance solenoid-pilot design. This design utilizes
elevated temperature applications. available media pressure/force to shift valve assuring
positive shifting. This design also produces the lowest
wattage ratings in the industry.
Large Diameter Pilot
The Pilot design is
maximized to offer positive
shifting throughout range
while residual volume is Elastomer Packed Spool
reduced for less air per shift. “Low friction” type seals are
A U-cup is utilized for bubble utilized to offer bubble tight sealing
tight sealing while reducing throughout valve operation range.
shift friction to a minimum.

Balanced Spool
The forces required to
actuate the plunger are
unaffected by pressure
being controlled assuring
positive shifting throughout
the entire pressure range.

Investment Cast Stainless Steel Spring Return Device


316 stainless steel components Versa’s V-316 Series spring return
are utilized for superior corrosion Full Flow - Over Ported valves offer the strongest spring return
protection in the harshest environments. Internal high flow area through ratings on the market assuring a positive
Investment cast components offer a valve is maximized so user is shift when valve is commanded to shift.
first class finish, while providing weight assured the fitting will reduce
savings and maximized flow paths for flow not the Versa valve.
superior flow.

EVERY VALVE FUNCTIONALLY TESTED THROUGHOUT COMPLETE PRESSURE RANGE BEFORE SHIPPING

COMPATIBILITY & APPLICATION RANGE: Series V-316 valves are designed for the control of pneumatic pressures
from partial vacuum to 200 psi (14 bar). Because Versa uses various styles and compounds of elastomers, it is
possible to meet varying conditions of media and temperature.
Limitations generally apply to specific types of actuation, such as solenoid or pilot. The minimum and maximum
pressures in these cases are dependent upon valve size, method of return actuation, valve series, and range of
pressure being controlled. For specific information, refer to specification pages 6 thru 9.

www.versa-valves.com 3
HOW TO SELECT A VERSA VALVE
Every letter and digit in the product number has significant meaning. The product number shown below (VSG-4522-316-L14-A120) indicates the following:

V S G 4 5 2 2 316 L14 A120


PNEUMATIC SPRING SOLENOID PILOT- FOUR-WAY 1/2” NPT SIDE PORTED TWO 316 STAINLESS SOLENOID OPERATOR 120V60 COIL
SERVICE RETURN ACTUATED (INPILOT) POSITION STEEL EQUIPPED WITH DUST
EXCLUDER NUT

BASIC PRODUCT NUMBER

V
VALVE
S ACTUATING DEVICES
G 4
FUNCTION:
5
PORT
SERIES ON LEFT END OF VALVE
LOOKING AT INLET
ON RIGHT END OF VALVE
LOOKING AT INLET
Body Style SIZE
V-316 Series Valve A Special actuator of any type. Letter indicates position of 2 Two-Way* 3 ¼” NPT
Pneumatic service to actuator relative to right and left end of body. 3 Three-Way
200 psi (14 bar) Suffix detail is required to designate specific actuator 4 Four-Way 4 ⅜” NPT
B Spring Centering (for 3 position manually operated
valves) 7 Two-Outlet (Directional 5 ½” NPT
G Solenoid-Pilot/2 position Three-Way-Diverter)
I Palm Button 7 1” NPT
J Pilot-Spring Centering (for 3 position pilot operated 8 Two-Inlet (Directional
valves) Three-Way-Selector)
L Hand Lever (centerline lever)
N Non-return Device (for manually operated valves —
allows valve to be positioned anywhere without detents)
P Pressure Pilot/2 position * Two-Way is accomplished by
R Reverse Spring Return (for manually operated valves). plugging the exhaust port of a three-
Spring pulls valve spool way valve
S Spring Return. Spring pushes valve spool
U Three-Detent (for manually operated valves)
W Diaphragm-Pilot (low pressure-pilot)
X Solenoid-Pilot Spring Centering (for 3 position
solenoid operated valves)
Y Diaphragm-Pilot Spring Centering (for 3 position diaphragm
operated valves)
Z 2-Position Detent
(for 2-position manually operated valves)

4 www.versa-valves.com
SELECTOR CHART
SUFFIX DETAILS
Suffix details indicate modifications or varia-
tions to the basic valve. When specifying
simply add those suffix details required in
alphabetical and/or numerical order.

Listed below are the suffix detail modifications found in this catalog and the page on which they are noted.

2 2 316
BODY
SPOOL
L14 COIL
CODE

DETAILS SUFFIX DETAILS VOLTAGE


DETAILS
(Flow patterns)
0 SIDEPORTED– THREE-WAY VALVES “316” indicates that the basic Actuator Orientation: Solenoid actuated
EXPILOT Two Position construction material for valve parts is -218A thru -218C, Hand Lever, page 10 valves require a Coil
Body with integral, 1 Normally Closed AISI 316 Stainless Steel (conforms to -227A thru -227C, Pilot actuator, page 12
Code that indicates the
pipe threaded ports. (actuating device must NACE Standard MR-01-75) Combination Actuators: specific coil current/
This type of body is be on right end of valve) -33E, Retainer cap
-113LE, Hand/2-detent, page 26 frequency and voltage.
directly connected to 2 Normally Open (actuating
pressure lines and is device must be on left -114LE, Hand/3-detent, page 26
-115E, Palm button/2-detent, page 26 The Coil Code consists
used for mechanical, end of valve) -130LAE Hand/spring return, page 26 of a letter to indicate the
manual and EXPilot* -136E, Palm button/spring return, Page 26
type solenoid or pilot THREE-WAY VALVES -138E, Solenoid/spring return, page 276 current frequency:
actuated valves. Three Position -150E, Pilot/2-detent, page 27
3 All ports blocked in -159E, Pilot/spring return, page 27
2 SIDEPORTED – center position -173E, Solenoid/spring return, page 27 Rating Code:
-181DRE, Latching Resets Page 26
INPILOT A= 60Hz frequency
Body same as “0” FOUR-WAY VALVES Solenoid Options; D= Direct Current (DC)
above, except it has Two Position For General Purpose (Page 7-9): E= 50Hz frequency
-HC, -HCC, DIN connector,
an auxiliary internal 2 Standard flow pattern: -HT, Class H coil
passage to supply inlet alternately open to -PC, -PS, Potted coil Three numbers follow
INPilot** type solenoid one cylinder port; For Hazardous Service (Page 7-9): the Rating Code to
and pilot actuators. opposite cylinder port -XX, Hazardous locations, UL & CSA indicate voltage:
alternately open to -XN, (d)Flameproof, ATEX
*Separate pressure line exhaust. -LB, Low Power, 1.8 Watt
-LA, Low Power, 0.85 Watt Examples:
connection needed to
-HT, Class H coil, Voltage Code
supply solenoid-pilot. FOUR-WAY
-PC, Potted coil, 24V60 = A024
Three Position -ST, Stainless steel housing,
**Internal auxiliary (Offset flows as standard 120V60 = A120
-XISC, -XISX6 (ib)Intrinsic Safe, ATEX FM & CSA
porting supplies flow patterns, above) -HC, -HCC, Connector for IS 24VDC = D024
pressurized medium Center Position Popular Option Combo’s for Hazardous Service:
being controlled to 3 All ports blocked -XXN, Hazardous, weather protected, UL/CSA (-LB, -PC, -XX)
pilot, solenoid- pilot.. 4 Cylinder ports open to -XXJ, Hazardous, enhanced weather protected, UL/CSA (-LB, -PC, -ST, -XX) See Page 7 for specific
exhaust -XNN, Hazardous, weather protected, ATEX (-LB, -PC, -XN) coil and codes.
-XNJ, Hazardous, enhanced weather protected, ATEX (-LB, -PC, -ST, -XN)
DIVERTER & For Hazardous Service WITH INTEGRAL Junction Box (Page 7-9):
SELECTOR VALVES -XDBS, -XDBT, (d)Flameproof, ATEX, IEC, CSA, INMETRO
2 2-position -XIFA, -XIFE, -XIFF, (ib)Intrinsic Safe, ATEX
3 All ports blocked in -XMAA, -XMAE, -XMAF, (m)Encapsulation, (e)Increased Safety, ATEX
center position -XMFA, -XMFE, -XMFF, (m)Encapsulation, (e)Increased Safety, ATEX
Manual Override (page 13):
-ME, Unguarded
Seals:
-44 Low temp Buna 6
-155, Fluorocarbon FKM, page 6
Special service/lubrication:
-DG-Dust Proof
-D14 Dust excluder, page 13
-L14, Silencer/dustproof coil cover nut, page 13
-55A, FDA approved silicone grease
-55M, Silicone grease
-200E, Plus pressure rating to 200 psi (14 bar), page 6
-H, Threaded solenoid exhaust, page 13
-NGS Natural Gas Service
-NGST Natural Gas Service – Low Temperature
Tagging:
-NV28A, Stainless steel ID tag; see Product Bulletin 181 page 13

www.versa-valves.com 5
SPECIFICATIONS
PORT SIZE - FLOW
Port Flow Diameter Flow Factor GASES LIQUIDS Assumptions:
Inlet pressure =
Size inch mm Cv SCFM = 22.5 CV ΔP (Outlet psi abs) GPM = CV ΔP psi Flow = Air
100 psi (7 bar)
1/4 NPT 3/8 9.5 1.8 (460° + F°) (SG) (SG) ΔP = 40 psi Outlet abs =
(3 bar) 74.7 psi (5 bar)
3/8 NPT 3/8 9.5 2.0 Temp = 68°F
1/2 NPT 5/8 16.0 5.5 SG = 1.0
(20°C)
1 NPT 1-1/16 27 11.1

MATERIALS
Valve body and internal parts: 316L stainless steel
Actuator caps: 316L stainless steel
Valve body/actuator seals: FKM – fluorocarbon (diaphragm, Buna)
Optional: Low Temperature Nitrile (-44)
Ethylene Propylene (-EP)
Screws: 316 stainless steel
Solenoid internal parts: 300 & 400 grade stainless steel
Solenoid Coil housing: Dependent on coil selected, see page 8 - 9

MEDIA
Air / inert gas, including natural gas. Consult factory for hydraulic service.
The standard V-316 Series product is rated for air and gas service including natural gas. While the standard valve is rated for
natural gas, Versa recommends suffix detail –NGS for enhanced valve performance (-NGST for low temperature applications).
Versa Products Company’s valves and accessories are intended for use in clean dry air or inert gas systems. Versa requires
filters of 40 microns or better. Versa defines “dry” as a system where dew point is 20°F below the minimum temperature to which
any part of the system is exposed.
Versa’s products are rated for lubricated or non lubricated service. On lubricated service, care should be taken to follow the
lubricator manufactures’ recommendations as to use and maintenance. As Versa ‘s products are elastomer sealed devices, seal
compatibility with media, lubricator fluid and environmental conditions should be confirmed,

PRESSURE RANGES
OPERATING PRESSURE RANGE
MINIMUM PILOT PRESSURE*
TYPE OF THROUGH VALVE
TYPE OF RETURN (When Applicable)
ACTUATION (CONTROLLED PRESSURE)
1/4 - 1/2 1 1/4 - 1/2 1
Spring, Spring Centering, VAC. - 200 psi
Manual — — —
Detent (VAC. - 14 bar)

Spring Return, 2 Position VAC. - 200 psi VAC. - 200 psi 40 psi (2.8 bar) 50 psi (3.5 bar)
(VAC.- 14 bar) (VAC.- 14 bar)
Pressure VAC. - 200 psi
Spring Centering, 3 Position — 40 psi (2.8 bar) —
Pilot (VAC.- 14 bar)
VAC. - 200 psi VAC. - 200 psi
2 Position, Dual Pilot 20 psi (1.4 bar) 20 psi (1.4 bar)i
(VAC. - 14 bar) (VAC.- 14 bar)
Spring Return, 2 Position VAC.- 200 psi 10 - 50 psi MAX
PILOT — —
Spring Centering 3 Position (VAC. - 14 bar) (0.7 - 3.4 bar MAX)
Spring Return, 2 Position VAC.- 200 psi 10 - 200 psi MAX
-31 — —
Spring Centering 3 Position (VAC. - 14 bar) (0.7 - 14 bar MAX)
Diaphragm
VAC.- 200 psi 5 - 50 psi MAX
2 Position, Dual Diaphragm — —
(VAC. - 14 bar) (0.34 - 3.4 bar MAX)
VAC.- 200 psi 5 - 200 psi MAX
2 Position, Dual Diaphragm -31 — —
(VAC. - 14 bar) (0.34 - 14 bar MAX)
40 - 175 psi †
40 - 175 psi† 40 - 175 psi MAX† 50 - 175 psi MAX
Spring Return, 2 Position (2.8 - 12 bar)† (2.8 - 12 bar)† (2.8 - 12 bar MAX)† (3.5 - 12 bar MAX)
40 - 175 psi †
40 - 175 psi MAX†
INPilot Spring Centering, 3 Position (2.8 - 12 bar)† — (2.8 - 12 bar MAX) —
20 - 175 psi †
20 - 175 psi MAX †
20 - 175 psi MAX †
20 - 175 psi MAX
2 Position, Dual Solenoid (1.38 - 12 bar)† (1.4 - 12 bar MAX)† (1.4 - 12 bar MAX)† (1.4 - 12 bar MAX)
SOLENOID
PILOT VAC. - 200 psi† VAC - 200 psi MAX† 40 - 200 psi MAX† 50 - 200 psi MAX
Spring Return, 2 Position (VAC. - 14 bar) (VAC - 14 bar MAX)† (2.8 - 14 bar MAX)† (3.5 - 14 bar MAX)
VAC. - 200 psi† VAC - 200 psi MAX† 20 - 200 psi MAX† 20 - 200 psi MAX
EXPilot Spring Centering, 3 Position (VAC. - 14 bar)† (VAC - 14 bar MAX)† (1.4 - 14 bar MAX)† (1.4 - 14 bar MAX)
VAC. - 200 psi† VAC - 200 psi MAX† 20 - 200 psi MAX† 20 - 200 psi MAX
2 Position, Dual Solenoid (VAC. - 14 bar)† (VAC - 14 bar MAX)† (1.4 - 14 bar MAX)† (1.4 - 14 bar MAX)
Notes: — When application involves temperatures below freezing or when shifting intervals are relatively long, it is recommended that suffix -S be
specified for valves with spring actuation. Minimum pilot pressure must be increased by 40%.
*All standard solenoid valves with maximum operating pressure or pilot pressure listed at 175 psi (12 bar) may be plus pressure rated to a maximum
of 200 psi (14 bar). Specified by adding suffix -200 to model number.

6 www.versa-valves.com
SPECIFICATIONS
TEMPERATURES - SEALS

Type of Service
Temperature Intermittent Duty Service Continuous Duty Service
Range
(Medium/Ambient AC or DC AC DC
Temperature)
Coil Solenoid Plunger Coil Solenoid Plunger Coil Solenoid Plunger

150ºF to 200ºF Suffix -HT Suffix -3 (may be Suffix -3 (may be Suffix -3 (may be
(65ºC) (95ºC) inclusive in other suffix Suffix -HT inclusive in other suffix Suffix -HT inclusive in other suffix
options as it is in -HT) options as it is in -HT) options as it is in -HT)

120ºF to 150ºF Standard Suffix -3 (may be Suffix -3 (may be Suffix -3 (may be


(50ºC) (65ºC) inclusive in other suffix Standard inclusive in other suffix Suffix -HT inclusive in other suffix
options) options) options as it is in -HT)

-10ºF to 120ºF
Suffix -3 (may be Suffix -3 (may be
(-23ºC) (50ºC) Standard Standard Standard inclusive in other suffix Standard
options)
inclusive in other suffix
options)
The table above lists suggested suffix options for various temperature ranges and/or types of service. For temperatures or conditions not listed, consult factory.

SOLENOID/PILOT — COIL SPECIFICATIONS*

AC DC
Solenoid Suffix
(see page 8) Voltage Voltage Inrush/
Voltage Inrush Holding Ohm Voltage Ohm
Code Code Holding
24/60 A024 0.633 0.491 26.2 6 D006 1.760 3.4
120/60 A120 0.127 0.098 647 12 D012 0.863 13.9
-HC & -HCC 240/60 A240 0.063 0.049 2790 24 D024 0.440 54.6
110/50 E110 0.127 0.098 647 48 D048 0.216 222
220/50 E220 0.063 0.049 2790 125 D125 0.055 1606

24/60 A024 0.633 0.604 19 6 D006 1.300 4.6


120/60 A120 0.127 0.121 475 12 D012 0.632 19
Standard, -PC,
240/60 A240 0.063 0.060 2000 24 D024 0.320 75
-243, -XX & -XN
110/50 E110 0.132 0.081 475 48 D048 0.154 311
220/50 E220 0.066 0.041 2030 125 D125 0.062 2030

24/60 A024 0.290 0.150 43.2 6 D006 0.320 18.8


120/60 A120 0.060 0.030 1085 12 D012 0.160 74.6
-XX & -XN with -LB 240/60 A240 0.030 0.020 5521 24 D024 0.077 312
110/50 E110 0.130 0.080 1085 48 D048 0.036 1337
220/50 E220 14.500 0.070 5521 125 D125 0.015 8460

24/60 A024 20 6 D006 0.300 20


120/60 A120 0.062 0.029 687 12 D012 0.150 80
-XDBT_ & -XDBS_
240/60 A240 2714 24 D024 0.075 320
(1.8 Watts)
110/50 E110 687 48 D048 0.038 1280
220/50 E220 0.032 0.016 2714 125 D125 0.016 8000
* Coils for voltages other than those listed above may be available.
Class H (Suffix –HT) coils are available for ordinary and hazardous service.
Contact factory for availability and delivery information.
Note: Coil Cover — Standard provides 1/2” NPT female conduit connection. Use Suffix –HC or –HCC for DIN style coil connector.
Coil Lead length — Standard coil lead lengths are at least 24” (60cm). Consult factory for availability of longer lead lengths.

www.versa-valves.com 7
SOLENOID PILOT – ELECTRICAL CERTIFICATIONS
Solenoid/Pilot actuated Series V-316 valves are available with a variety of different solenoids for both nonhazardous and hazardous
locations. Basic details of actuators are listed below. For additional data consult factory.

NONHAZARDOUS LOCATION SOLENOIDS


Suffix Protection Area Classification Certification- Ingress
Identification Classification and (Gas Grouping) (Conformance) Protection

None or NEMA 1,2,


General Purpose Indoor & Outdoor UL - CSA
-HT, PC 3&4

-HC CSA NEMA 4;


General Purpose Indoor & Outdoor
-HCC (Shown) (AC only) IP65

HAZARDOUS LOCATION OPERATORS (See page 35 for option recommendations)


Suffix Protection Area Classification Certification- Ingress
Identification Classification and (Gas Grouping) (Conformance) Protection
-XX (see page 35
for additional coil CLASS I, DIV. 1 (C & D)
options) Hazardous CLASS I, DIV. 2 (A & B) UL - CSA NEMA 7 & 9
-LB-XX (see page Locations CLASS II, DIV. 1 (E, F & G)
35 for additional coil
options)
-XN (see page 35
for additional coil Ex d IIB+H2 T3 to T6 Gb IECEx
options)
(d) Flameproof IP65 & IP66
-LB-XN (see page
35 for additional coil II 2 G Ex d IIB+H2 T3 to T6 ATEX
options)
EX II 2 G D ATEX - IECEx IP66, IP67,
Ex de IIC T* Gb INMETRO & IP68
-XDBS* EX tb IIIC T* ºC Db
Cl, I Zone 1 AEx de IIC T* CSAUS
C

Cl, II Zone, 21 AEX tD A21, DIP A21


(d) Flameproof EX II 2 G D ATEX - IECEx
(e) Increased Safety Ex de IIC T* Gb INMETRO
EX tb IIIC T* ºC Db
NEMA 4, 4X
-XDBT* Cl I Grp B, C & D, Cl, II Grp E, F & CSAUS
C 6P
G, Cl III
Cl, I Zone 1 AEx de IIC T*, Cl, II
Zone, 21 AEX tD A21, DIP A21
XDB_See “Miscellaneous” column page 9 for ordering information.
-XMAA
-XMAE
Ex e mb II T5, T6 Gb IECEx
-XMAF
(mb) Encapsulation Ex tD A21 T100ºC, T85ºC Db
-XMAG TR CU
(e) Increased Safety IP66 & IP67
-XMFA (tD) Tight Dust II 2 G Ex e mb II T5, T6
-XMFE II 2D Ex tD A21 T100ºC, T85ºC ATEX
-XMFF
-XMFG

Ex (ia) IIC T4...T6 Gb IECEx


-XIFA Ex (ia) IIIC T130ºC, T80ºC Db TR CU
-XIFE IP66 & IP67
-XIFF II 2 G Ex ia IIC T4...T6
(ia) Intrinsic Safe ATEX
II 2 D Ex iaD 21 T130ºC, T80ºC

ATEX
-XISX6 II 2 G EEx ia IIC T6 IECEx
TR CU
IP65
Class I, Groups (A, B, C & D)
Factory Mutual
-XISC Intrinsic Safe Class II, Groups (E, F, &G)
CSA
Class III
*For XDAS or XDAT consult factory

8 www.versa-valves.com
COIL CODES: Identify the solenoid frequency Rating Code Voltage
and voltage consisting of a “Rating Code” and A = 60Hz frequency Indicated by three digits: A120 = AC,120Volts/60hz
“Voltage” as shown at right. Coil codes complete D = Direct Current (DC) e.g. 24 volts = 024
the part number for a solenoid operated valve. E = 50Hz frequency 120 volts = 120

Voltage Electrical
(Power) Characteristics Miscellaneous
All usual 50 Hz & 60 Hz AC (6W) Class F epoxy molded coil Steel, painted coil housing with 1/2 NPT conduit entry.
All usual DC (7W) (155ºC).
Continuous duty, 2 leads 24”
(60 cm).
24V60, 120V60, 240V60 (8.5W) Class F epoxy molded coil Mini DIN socket with PG9 cable gland (-HC) or 1/2” conduit
24V50, 110V50, 220V50 (8.5W) (155ºC), with 3 spade terminals. connection (-HCC).
12VDC, 24VDC, 48VDC (10.5W) Continuous duty.

Voltage Electrical
(Power) Characteristics Miscellaneous

All usual 50 Hz & 60 Hz AC (5.6W) Plated steel coil housing with 1/2 NPT conduit entry.
All usual DC (7.2W) For stainless steel (430 type) coil housing add: (-ST)

12V60, 24V60, 48V60, 120V60, Plated steel coil housing with 1/2 NPT conduit entry. For
240V60 (1.8W) stainless steel (430 type) coil housing add: (-ST) Maximum
6VDC, 12VDC, 24VDC, 48VDC (1.8W) Class F epoxy molded coil pilot pressure 120 psi (8 bar). 1.8W nominal power.
(155ºC),
Continuous duty. 3 leads 24” Plated steel coil housing with M20 x 1.5 conduit entry.
All usual 50 Hz & 60 Hz AC (5.6W) Ground terminal on cover.
All usual DC (7.2W) (60 cm).
For stainless steel (430 type) coil housing add: (-ST)
Plated steel coil housing with M20 x 1.5 conduit entry.
12V60, 24V60, 48V60, 120V60, Ground terminal on cover.
240V60 (1.8W) For stainless steel (430 type) coil housing add: (-ST)
6VDC, 12VDC, 24VDC, 48VDC (1.8W) Maximum pilot pressure 120 psi (8 bar) 1.8W nominal power.

Stainless steel coil housing Suffix Detail Ordering Code


with internal Junction Box. M 20 Connection ½” Connection
Internal and external ground
24VDC (D024) screw. No Diode Diode No Diode Diode
120V60 (A120) 110V50 (E110) Epoxy molded coils rated for Standard (vent to atmosphere) XDBS1 XDBS5 XDBT1 XDBT5
230V50 (E230) continuous duty, Class H,
180°C. 1/8” Adapter (-H2E) XDBS2 XDBS6 XDBT2 XDBT6
1.8 Watt standard, for lower watt con-
tact factory. 1/4” Adapter (-HE) XDBS3 XDBS7 XDBT3 XDBT7
Dust Nut (-L14) XDBS4 XDBS8 XDBT4 XDBT8
Dust Excluder (-D14) XDBS9 XDBS10 XDBT9 XDBT10

24VDC (4W) Continuous duty. Coil & rectifier,


(Consult factory for other voltage op- including surge suppression, Thick wall epoxy coil housing with integral
tions) potted within housing. junction box. Internal ground terminal.
M20 x 1.5 conduit entry: (-XMAA), (-XMFA),
Cable gland for 6-12 mm ø cable: (-XMAE), (-XMFE)
24VDC 1/2 NPT conduit entry with adapter: (-XMAF), (-XMFF)
Continuous duty. Coil & power Cable gland for 9-16 mm ø cable: (-XMAG), (-XMFG)
(10W inrush, 4 W holding) controller potted within housing.
(Consult factory for other voltages)

Requires the use of an approved safety barrier or isolator.


Thick wall epoxy coil housing and integral junction box.
Continuous duty. Coil and
24VDC (0.8W) Internal ground terminal.
power controller potted within
(Consult factory for other voltages) M20 x 1.5 conduit entry: (-XIFA)
housing. Cable gland for 6-12 mm ø cable: (-XIFE)
1/2 NPT conduit entry with adapter: (-XIFF)

Requires the use of an approved barrier or isolator.


Maximum operating system voltage before barrier 28VDC.
24VDC Class F epoxy molded coil Maximum pilot pressure 115 psi (8 bar).
system voltage prior to barrier (155ºC). 3 spade terminals & DIN connector with PG9
(1.6 watt max.) Continuous duty. cable gland: (-HC)
1/2 NPT conduit entry: (-HCC)

www.versa-valves.com 9
ACTUATING DEVICES
The basic purpose of the actuating device is to provide a means of shifting the valve spool in order to control the media flowing
through the valve. Because the valve’s spool design is balanced, the force required to shift the spool, is separate and unaffected
by the pressure being controlled.

The actuators are designed for application within 2 ranges of valve sizes: one range of actuators for all valve styles, types, and
sizes ¼” through ½”; another range of actuators for the 1” size valves.

Illustrated with brief descriptions are the basic types of actuators in most frequent use. The “letters” referred to by the actuator
types coincide with the prefix letters used in the product numbering system. Many variations and modifications of these basic
actuators are also available. A few are described on Page 5 under Suffix Details. Others, such as combination actuators, can
be found on Pages 26 and 27.

MANUAL
A push or pull motion may be used to operate the hand device in order to shift the valve spool. If used with a detent device (“U”
or “Z”) or a no-spring device (“N”) the handle must be actuated and returned manually. With a spring centering device (“B”) the
handle will normally be in the center position when not actuated, or will return to the center position after being actuated. To
actuate with a spring centering device, the handle must be pulled to one offset position and pushed to the other. The precise
differences of each of the three hand actuating devices are described below.

TYPE “L” HAND LEVER (Centerline Mounted)


The handle of this device is in the vertical plane through the center line of the valve
body. On models up to ½” pipe size, a rubber boot provides protection from dirt and
dust. The entire device may be rotated into positions at increments of 90° from vertical.
To indicate, use Suffix –218A, –218B, or –218C as shown below for offset mounted
hand lever.
HANDLE POSITIONS
STD STD

OPTIONS
Hand valves are supplied according to standard position.
Three other positions are available (Suffix -218A Thru
218C 218A 218A 218C 218C). To order simply include the Suffix number shown.
Example: VSL-4302-316-218A.
INLET
VSL PORT VLS
218B 218B

HAND LEVER

TYPE “I” PALM BUTTON (Panel Mounting Is Standard)


The body of the Palm Button actuator is supplied with a thread and nut that
allows the actuator, when required, to be fastened to a panel with the valve
behind the panel. The button will then project through and be visible
from the front panel. Pushing or pulling the button activates the valve.

PALM BUTTON
Shown with optional red knob

SPRING RETURN
A device for returning the valve spool to its original position in 2-position valves.
TYPE “S”
Can be used on any type valve. Pushes valve spool.
TYPE “R”
For use with Lever or Palm Button operated valves. Pulls valve spool.
DETENT
A device that establishes a definite “feel” indicating when valve is in a specific position.
Also prevents spool from shifting should excessive vibration be present. Generally
used with Hand Operated valves, but can also be supplied, in some cases, for Pilot
and Solenoid/Pilot Operated valves as a Combination Actuator.

SPRING RETURN
10 www.versa-valves.com
ACTUATING DEVICES
NO-SPRING RETURN
TYPE “N”
For use on Palm or Lever Operated valves only. Used when automatic
return of valve spool is not desired. Spool will stay in last position
placed until operated to another position
TYPE “U”
3-Position detent for 3-Position valves. Provides detent in each offset
position and center position as well.
TYPE “Z”
2-Position detent for 2-Position valves. Provides detent in both offset positions.

SPRING CENTERING DEVICE


A device for returning the valve spool to center position in manual valves
only. Spring centering devices for Pilot or Solenoid/Pilot Operated valves
are an integral part of the specific actuator.
TYPE “B”
Spring centers from both offset positions.
SPRING CENTERING

KEY Operated
TYPE “314”
KEY OPERATED VALVE, KEY REMOVABLE IN ONE POSITION
314E: key can only be removed in the “normal Position.” The valve
must have a return spring, detent or pilot on end opposite key.
Captive dust cap and two keys supplied. Panel mounting
provision is standard.

KEY OPERATED VALVE, KEY REMOVABLE IN TWO POSITIONS


314D: key is removable after key has been rotated to the
clockwise or counter-clockwise position. The valve must have
a two detent on end opposite key. Captive dust cap and two
keys supplied. Panel mounting provision is standard.

KEY OPERATED

Rotary Switch
TYPE “357”
Rotary switch actuated valve (detented)

Rotary Switch

Lockout Valve
TYPE “LOVEE”
A valve which can be locked in either pressurized
or exhausting positions. Standard Knob is black,
optional green and red available.

TYPE “LOVBE”
A valve that can only be locked when cylinder port
is open to exhaust. Valve locks with button pushed
in. Standard Knob is black, optional green and red
Lock Out Valve
available.

www.versa-valves.com 11
ACTUATING DEVICES
PILOT
The pilot actuator is a small cylinder and piston that is an
integral part of the valve and which, when pressurized or un-
pressurized, actuates the valve.
TYPE “P” PRESSURE PILOT (for 2-Position valves)
TYPE “J” PRESSURE PILOT (for 3-Position valves)
This pilot requires pressure to actuate the valve, and release of
the pressure to return the valve. Usually it is controlled by a small
Three-Way valve. The pilot port on the ¼” through ½” valves may
be rotated to any position in 90° increments from vertical. (See
option arrangements below). When used in pairs for 2-position
valves, it is not necessary to maintain pressure on the actuated
pilot in order for the valve to remain in actuated position. Valve will
remain in last position until signalled by the opposite pilot to return. PILOT -P
When used with spring centering feature (“J”), valve will remain in
center position until actuated by either pilot. To remain in actuated
position, pilot must remain pressurized until it is required for valve
to return to center position.
PILOT POSITION OPTIONS

227A Pilot actuated valves (¼” thru


STANDARD ½”) are supplied with the pilot
POSITION OF 227B port facing the same direction
PILOT INLET as the inlet port of the valve
proper. Three other positions
227C
are available (Suffix -227A thru
-227C).
To order simply include the PILOT -J
suffix number shown.
Example: VSP-4302-316-227A.

TYPE “W” DIAPHRAGM PILOT (for 2-Position valves)


TYPE “Y” DIAPHRAGM PILOT (for 3-Position valves)
A large pilot area allows the diaphragm pilot to function on very
low signal pressures. Usually controlled by a Three-Way valve,
the diaphragm pilot requires pressure to actuate. When used in
pairs for 2-position valves, it is not necessary to maintain pressure
on actuated pilot in order for valve to remain in actuated position.
Valve will remain in last position until signalled by opposite pilot
to return. When used with spring centering feature (“Y”) valve
will remain in center position until actuated by pilot. To remain in
actuated position, pilot must remain pressurized until it is required
for valve to return to center position.
DIAPHRAGM PILOT -W

DIAPHRAGM PILOT -Y

12 www.versa-valves.com
ACTUATING DEVICES
SOLENOID/PILOT
A low power solenoid controls a built-in pilot which provides the positive
force for shifting the valve spool. When used with a spring return (“S”)
the valve will be actuated when the solenoid is energized and will return
when the solenoid is de-energized. When used in pairs for 2-position
valves, the solenoid need only be energized momentarily in order to
shift the valve. The valve will then remain in the shifted position until
signalled to return by the opposite solenoid. In spring centering models
(“X”) the valve will remain in the center position until one of the solenoids
is energized. It is necessary to maintain energy on the solenoid as long
as it is desired for the valve to remain in the shifted position. When de-
energized, the valve will return to the center position.

STANDARD COILS are epoxy molded in a steel inclosure with ½” con-


duit hub. For AC and DC voltages available, see Pages 7 - 9.
Two Piloting devices are available depending upon the service to which
GENERAL PURPOSE SOLENOID
they will be applied:
INPilot– utilizes the pressure from the inlet of the valve, through
internal passages, to the solenoid-pilot. In this type valve, only
one pressure connection, the inlet, is necessary.
EXPilot– requires a separate auxiliary pressure line to the
solenoid-pilot. Should be used when valve is controlling vacuum,
when pressure will be below the minimum recommended for
INPilot operation or when viscosity of controlled medium is
such that it will impede the speed of actuation. In any case, the
pressure source may be either air or liquid and is independent of
the medium which is being controlled by the valve.
EXPILOT
PORT
TYPE “G” UPRIGHT SOLENOID/PILOT (for 2-Position valves)
TYPE “X” UPRIGHT SOLENOID/PILOT (for 3-Position valves)
Coils of actuator are placed on top of solenoid cap so as to be
perpendicular to the longitudinal axis of the valve. Shortens overall
length of valve. Used as standard for valves equipped with hazardous
HAZARDOUS LOCATION SOLENOID location solenoids (suffix “-XX”) or plug-in solenoids, (suffix “-P”).

Solenoid Vent Options

SOME AVAILABLE OPTIONS


• Manual Override: (Suffix -ME)
• Threaded Solenoid Exhaust Adapter:
(Suffix -H -H2)
• Dust excluders for solenoid exhaust:
Dust Proof: (Suffix -L14)
Water Tight: (Suffix -D14)

OVERRIDE Hydraulic Adapter Excluders


-ME -H2 ⅛” -L14 -D14
-H ¼” Dust Proof Water Tight

STAINLESS STEEL TAG


ORDERING INFORMATION Engraving Options
Versa's engraved tags are available in two configurations.
Order any Configuration one: is a simple text field
2.25”
B-316, C-316, T, consisting of two lines of text, 20 characters
ABC OIL
V or V-316 valve. maximum per line. The text can be specified 0.5”
P/N SV 966
As a separate as alpha, numeric or both.
line item (listed directly under valve part number to be tagged) list
the tag part number P- 2002-16-NV28A. In remarks field specify Configuration two: is a text field with
the tag marking instructions. If sequential numbering is required sequential numbering added. This option ABC OIL
provide the start and end numbers required in the sequence for includes two lines of text. Line one is text. P/N SV 966
the appropriate number of valves. Line two allows for sequentially numbering Field for Sequential Characters
the tag, 20 characters maximum per line.

www.versa-valves.com 13
WAY VALVES 3/2 and 3/3
Three-Way Valves may be either normally open or normally closed to the inlet
in the un-actuated position. Three-Way Valves are usually used to control
single acting cylinders or the pilots of other valves or devices. Two additional
types of Three-Way Valves are available.

Diverter: a common inlet that directs flow to either one of two outlets.
Selector: two separate inlets that are alternately connected
to a common outlet.

Shown: VSG-3501-316-PC-XX-D024
NOMINAL PRESSURE RANGE ACTUATION
Series “V-316”: partial vacuum to 200 psi MANUAL, MECHANICAL, PILOT
(14 bar) pneumatic or SOLENOID-PILOT
(Consult pressure rating chart on Page 6
for specific pressure rating of each valve.)

TYPES:

Manual Pilot

Shown: VSL-3401-316 Shown: VSP-3701-316

PORT SIZES: 1/4”, 3/8” 1/2” and 1” NPT

14 V-316 3-WAY www.versa-valves.com


SPECIFICATIONS
Refer to pages 6 through 9 for information concerning:
Construction Pressure Ranges
Seals Electrical
Port Sizes Temperature
Flow Filtration

STANDARD FLOW PATTERNS


Valves must be connected in accordance with the port markings so that the flow is from the inlet
port to the outlet port or from outlet port to exhaust. The flow within the valve should never be re-
versed. Note: When used in a vacuum system, the vacuum pump is connected to the exhaust port

THREE WAY
2 POSITION 3/2
1. VALVE NORMALLY CLOSED (actuator mounted on right end of valve)

A
A A

RET. ACT.
IN EX IN EX

UN-ACTUATED ACTUATED

2. VALVE NORMALLY OPEN (actuator mounted on left end of valve)

A
A A

ACT. RET.
IN EX IN EX

UN-ACTUATED ACTUATED
3 POSITION 3/3 (all ports blocked in the center position)
To indicate substitute number “3” for fourth digit of product number.
Otherwise Product Number and offset flow patterns remain the same.

TWO OUTLET (Diverter) To indicate substitute number “7” for first digit of product number.
2 POSITION 3/2
OUT 1 OUT 2
OUT2
OUT1

OUT 2 OUT 1

ACT. RET.
IN IN

3 POSITION 3/3 (all ports blocked in the center position)


To indicate substitute number “3” for fourth digit of product number.
Otherwise Product Number and offset flow patterns remain the same.

TWO INLET (Selector) To indicate substitute number “8” for first digit of product number.
2 POSITION 3/2

OUT
OUT

OUT

IN IN IN
RET. ACT.
IN
1 2 1 2

P1 P2

3 POSITION 3/3 (all ports blocked in the center position)


To indicate substitute number “3” for fourth digit of product number.
Otherwise Product Number and offset flow patterns remain the same.

www.versa-valves.com V-316 3-WAY 15


WAY DIMENSIONS
Port hole locations and mounting hole size and locations shown in the individual Body Detail below apply to all Three-Way
valves, regardless of type of actuation. The overall dimensions are shown for each type of valve.

BODY DETAIL C
D H Ø (3 MOUNTING HOLES)
C
HØ (2 MOUNTING HOLES)
D
2 2
A
A E
E
NETHERLANDS

VERSA®
N.J., U.S.A. &
G F
G F

IN EA
IN EA 3 1
3 1
B
B
A 1”NPT (3 HOLES)
A

1/4” - 1/2” Body 1” Body

A B C D E F G HØ
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm
1/4” - 3/8” 2.19 56 1.75 45 1.31 33 0.66 17 .80 20 1.59 40 2 51 0.27 6.7
1/2” 2.84 95 2.08 52.8 1.31 33 0.66 17 .80 20 1.59 40 2.5 63.5 0.27 6.7
1” 5.5 140 3.25 82.6 3.0 76 1.5 38.1 1.5 40 3.0 6.2 3.375 85.7 0.406 1.2

HAND ACTUATED VALVES


20º

F
G

E
C A B/B* D

A B B* C D E F G HØ J
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4” - 3/8” 2.19 55.6 1.15 29.2 1.78 45.2 1.65 41.9 2 51 1 25 1.56 39.6 0.75 21 0.56 14.3 6.3 160.3
1/2” 2.84 72 1.15 29.2 1.78 45.2 1.65 41.9 2.5 63.5 1.25 31.8 1.56 39.6 0.75 22 0.56 14.3 6.3 160.3

1” 5.5 140 2.01 0.51 — — 1.65 41.9 3.75 95.2 1.88 47.8 2.5 63.5 1.19 30.2 0.56 14.3 8.72 221.5

BUTTON ACTUATED VALVES


M PANEL HOLE Ø
K J MIN TRAVEL
MAX

F
G

H
B/B* A C MAX E
LØ D

A B B* C Max D E F G H J Min K LØ MØ
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4” - 3/8” 2.19 55.6 1.15 29.2 1.78 45.2 3.31 84 2 51 1 25 1.56 39.6 0.75 21 0.44 11.2 0.34 8.6 0.90 22.9 1.81 46 1 25.4
1/2” 2.84 72 1.15 29.2 1.78 45.2 3.31 84 2.5 63.5 1.25 31.8 1.56 39.6 0.75 22 0.44 11.2 0.34 8.6 0.90 22.9 1.81 46 1 25.4
*Dimensions for Spring-Centering Valves. For port and mounting hole locations for all valves shown above, refer to drawings top page 16.

16 V-316 3-WAY www.versa-valves.com


WAY DIMENSIONS
PIILOT ACTUATED VALVES (and Spring Centering)
SINGLE PILOT

VERSA

PILOT
F PARAMUS
N.J. U.S.A.
G

C A E
B/B* D

DOUBLE PILOT

PARAMUS
PILOT
PILOT

NJ USA
F V E R S A

E
C/C* A C/C* D

A B B* C C* D E F G
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4”- 3/8” 2.19 55.6 1.15 29.2 1.78 45.1 0.94 23.8 2.17 55.1 2.19 55.6 1.19 30.2 1.56 39.6 0.75 19.1
1/2” 2.84 72 1.15 29.2 1.78 45.1 0.94 23.8 1.86 .047 2.5 47.1 1.25 31.8 1.56 39.6 0.75 19.1
1” 5.5 140 2.01 0.51 — — 2 51 — — 3.75 95.2 1.88 47.8 2.5 63.5 1.19 30.2
*Dimensions for Spring-Centering Valves.

DIAPHRAGM ACTUATED VALVES (and Spring Centering)


SINGLE PILOT

F D
VERSA
PARAMUS
N.J. U.S.A.
G
E

E
C A B/B* D

DOUBLE PILOT

E
C/C* A C/C* D

A B B* C C* D E F
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm
1/4”- 3/8” 2.19 55.6 1.15 29.2 1.78 45.2 2.0 51 2.3 58.4 3.25 82.6 1.63 41.3 1.5 38
1/2” 2.84 72 1.15 29.2 1.78 45.2 2.0 51 2.3 58.4 3.25 82.6 1.63 41.3 1.69 43
*Dimensions for Spring-Centering Valves.
For port and mounting hole locations for all valves shown above, refer to drawings top page 16.

www.versa-valves.com V-316 3-WAY 17


WAY DIMENSIONS
SOLENOID ACTUATED VALVES (Non Hazardous Service)
SINGLE SOLENOID

J
1/8” NPT
Manual Override H PILOT
Pilot Port
(expilot
valves Only)

VERSA
F

E
B/B* A C D

DOUBLE SOLENOID

J
1/8” NPT
H PILOT Pilot Port
(expilot
valves Only)

VERSA
E
C/C* A C/C* D

A B B* C C* D E F G H J
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4” - 3/8” 2.19 55.6 1.15 29.2 1.76 45.1 1.62 41.3 2.54 64.6 2 51 1.0 25.4 1.56 39.6 2.98 75.7 2.86 72.5 3.75 95.3
1/2” 2.84 72.1 1.15 29.2 1.76 45.1 1.62 41.3 2.54 64.6 2.5 63.5 1.25 31.8 1.56 39.6 2.98 75.7 2.86 72.5 3.75 95.3
1” 5.5 139.7 2.01 151 — — 2.01 151 — — 3.75 95.3 1.88 47.6 5.17 131.3 4.29 109 5.17 131.3 4.29 109
*Dimensions for Spring-Centering Valves.

SOLENOID ACTUATED VALVES/INLINE (Hazardous Service Valves -XX -XN)


SINGLE SOLENOID

J
1/8” NPT
Manual Override H PILOT
Pilot Port
(expilot
valves Only)
VERSA

E
B/B* A C D

DOUBLE SOLENOID

J
1/8” NPT
H PILOT Pilot Port
(expilot
valves Only)
VERSA

E
C/C* A C/C* D

A B B* C C* D E F G H J
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4” - 3/8” 2.19 55.6 1.15 29.2 1.76 45.1 1.62 41.3 2.54 64.6 2 51 1.0 25.4 3.89 97.4 0.75 19.1 3.83 97.4 2.98 75.7
1/2” 2.84 72.1 1.15 29.2 1.76 45.1 1.62 41.3 2.54 64.6 2.5 63.5 1.25 31.8 3.89 97.4 0.75 19.1 3.83 97.4 2.98 75.7
1” 5.5 139.7 2.01 151 — — 2.01 151 — — 3.75 95.3 1.88 47.6 5.17 131.3 4.29 109 5.17 131.3 4.29 109
*Dimensions for Spring-Centering Valves. For port and mounting hole locations for all valves shown above, refer to drawings top page 16.

18 V-316 3-WAY www.versa-valves.com


WAY DIMENSIONS
SOLENOID ACTUATED VALVES (Hazardous Service -XDB_)
SINGLE SOLENOID K

1/8” NPT
Pilot Port
Manual Override (expilot PILOT H
valves Only)

VERSA
F

B/B* A C E
D

DOUBLE SOLENOID
K

1/8” NPT
Pilot Port
(expilot PILOT H
valves Only)

VERSA
C/C* A C/C* E
D

A B B* C C* D E F G H J K
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4”- 3/8” 2.19 55.6 1.15 29.2 1.76 45.1 1.62 41.1 1.76 45.1 0.69 17.5 2 51 1.56 39.6 0.75 19.1 2.83 72 5.16 131.2 2.5 63.5
1/2” 2.84 72.1 1.15 29.2 1.76 45.1 1.62 41.1 1.76 45.1 0.69 17.5 2.5 63.5 1.56 39.6 0.75 19.1 2.83 72 5.16 131.2 2.5 63.5
1” 5.5 139.7 2.01 151 — — 2.6 66 — — 2.59 65.8 3.75 95.3 1.88 47.6 1.19 30.2 4.9 124.3 6.84 164 2.5 63.5
*Dimensions for Spring-Centering Valves.

SOLENOID ACTUATED VALVES/INLINE (Hazardous Service Valves -XMA_)


SINGLE SOLENOID K

M20 x 1.5
F CONDUIT
ENTRY H
G

E
B/B* A C/C* D

DOUBLE SOLENOID K

M20 x 1.5
CONDUIT
ENTRY H

E
C/C* A C/C* D
10
A B B* C C* D E F G H J K
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4”- 3/8” 2.19 55.6 1.15 29.2 1.76 45.1 4.08 103.6 4.1 104.1 2 51 1.38 35 1.56 39.6 0.75 19.1 1.26 32 4.0 101 2.6 65
1/2” 2.84 72.1 1.15 29.2 1.76 45.1 4.08 103.6 4.1 104.1 2.5 63.5 1.25 31.8 1.56 39.6 0.75 19.1 1.26 32 4.0 101 2.6 65
1” 5.5 139.7 2.01 151 — — 4.36 110.7 — — 3.75 95.3 1.88 47.6 2.5 30.2 1.19 30.2 3.21 81.6 6.3 160 2.6 65
*Dimensions for Spring-Centering Valves. For port and mounting hole locations for all valves shown above, refer to drawings top page 16.

www.versa-valves.com V-316 3-WAY 19


WAY VALVES 5/2 and 5/3

Four-Way Valves are generally used to control double acting


cylinders. They function to alternately direct pressure to one
of two outlets at the same time exhausting pressure from the
opposite outlet.

Shown: VSG-4522-316-PC-XX-D024
NOMINAL PRESSURE RANGE ACTUATION
Series V-316: partial vacuum to 200 psi (14 bar) pneu- MANUAL, MECHANICAL, PILOT
matic. For hydraulic consult factory or SOLENOID-PILOT
(Consult pressure rating chart on Page 6
for specific pressure rating of each valve.)

BODY TYPES:

Manual Pilot
The side-ported body provides threaded
ports in the body of the valve.

Shown: VSL-4402-316 Shown: VSP-4302-316

PORT SIZES: 1/4, 3/8, and 1/2

20 V-316 4-WAY www.versa-valves.com


SPECIFICATIONS
Refer to pages 6 through 9 for information concerning:
Construction
Seals
Port Sizes
Flow
Pressure Ranges
Electrical
Temperature
Filtration

STANDARD FLOW PATTERNS


ONE INLET, TWO OUTLETS, TWO EXHAUSTS

Valves must be connected in accordance with the port markings so that the flow is from
the inlet port to the outlet port or from outlet port to exhaust. The flow within the valve
should never be reversed. Note: When used in a vacuum system, the vacuum pump is
connected to the outlet port

2 POSITION 5/2

B A
B A B A
RET. ACT.

EX IN EX EX IN EX P

Inlet open to cylinder port B, Inlet open to cylinder port A,


cylinder port A, open to exhaust. cylinder port B open to exhaust.

3 POSITION 5/3
Diagrams below show center position only. Offset positions are same as shown above for
2-position types. To indicate particular center pattern required, substitute number shown with-
in corresponding diagram for fourth digit of product number.

3 4

All ports blocked Cylinder ports


open to exhaust.

Inlet open to both


cylinder ports.

www.versa-valves.com V-316 4-WAY 21


WAY-MOUNTING DIMENSIONS
Port hole locations and mounting hole size and locations shown in the individual Body Detail below apply to all Four-Way
valves, regardless of type of actuation. The overall dimensions shown for each type of valve actuation apply whether for
side ported or sub-plate mounting type.

BODY DETAIL D HØ (Mounting


1/4” - 1/2” Body D
E
H Ø (Mounting 1” Body E Holes 3)
B4 A2 Holes 3)

F
F
N. J., U .S .A. &
NETHERLANDS

VERSA
G G
EB IN EA
5 3 4
C C
B C C
A
B
A

A B C D E F G HØ
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm
1/4” - 3/8” 3.5 89 1.75 44.5 1.31 33.3 1.32 33.5 0.66 16.7 1.56 39.6 0.80 20.2 0.27 6.7
1/2” 4.0 101.6 2.0 51 1.31 33.3 1.32 33.5 0.66 16.7 1.56 39.6 0.80 20.2 0.27 6.7
1” 8.5 215.9 4.25 108 3 76.2 3 76.2 1.5 38.1 3 76.2 1.5 38.1 0.4 1.2

LEVER ACTUATED VALVES


20º

F
G

B/B* A C E
D

A B B* C D E F G H J KØ
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4” - 3/8” 3.5 89 1.15 29.2 1.78 45.2 1.65 41.9 2 51 1 25 1.56 39.6 0.75 19 4 101.6 6.3 160.5 0.56 14.2
1/2” 4 101.6 1.15 29.2 1.78 45.2 1.65 41.9 2.5 63.5 1.25 31.8 1.56 39.6 0.75 19 4 101.6 6.3 160.5 0.56 14.2
1” 8.63 219.1 2.01 51 — — 2.01 51 3.75 95.3 1.88 47.6 2.5 63.5 1.19 30.2 4 101.6 8.72 221.5 0.56 14.2
*Dimensions for Spring-Centering Valves.

BUTTON ACTUATED VALVES


M PANEL HOLE Ø
K J MIN TRAVEL
MAX

F
G

H
B/B* A C MAX LØ E
D

A B B* C Max D E F G H J Min K LØ MØ
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4” - 3/8” 3.5 88.9 1.15 29.2 1.78 45.2 3.31 84 2 51 1 25 1.56 39.6 0.75 21 0.44 11.2 0.34 8.6 0.90 22.9 1.81 46 1 25.4
1/2” 4.0 101.6 1.15 29.2 1.78 45.2 3.31 84 2.5 63.5 1.25 31.8 1.56 39.6 0.75 22 0.44 11.2 0.34 8.6 0.90 22.9 1.81 46 1 25.4
*Dimensions for Spring-Centering Valves. For port and mounting hole locations for all valves shown above, refer to drawings top page 22.

22 V-316 4-WAY www.versa-valves.com


WAY-MOUNTING DIMENSIONS
SOLENOID ACTUATED VALVES (Non Hazardous Service)
SINGLE SOLENOID

J
1/8” NPT
Manual Override
H PILOT
Pilot Port
(expilot
valves Only)

VERSA
F

E
B/B* A C D
DOUBLE SOLENOID

J
1/8” NPT
PILOT
H Pilot Port
(expilot

VERSA
valves Only)

E
C/C* A C/C* D

A B B* C C* D E F G H J
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4”- 3/8” 3.50 88.9 1.15 29.2 1.84 47 1.62 41.3 2.54 64.6 2 51 1.0 25.4 1.56 39.6 0.75 19 2.86 72.6 3.75 95.2
1/2” 4.0 101.6 1.15 29.2 1.84 47 1.62 41.3 2.54 64.6 2.5 63.5 1.25 31.8 1.56 39.6 0.75 19 2.86 72.6 3.75 95.2
1” 8.63 219 2.01 51 — — 2.01 51 — — 1.88 47.8 2.5 63.5 1.19 30.2 1.19 30.2 5.39 136.9 5.39 136.9
*Dimensions for Spring-Centering Valves.

SOLENOID ACTUATED VALVES (Hazardous Service Valves. see Page 7 - 9)


SINGLE SOLENOID

J
1/8” NPT
Manual Override H PILOT
Pilot Port
(expilot
valves Only)
VERSA

E
B/B* A C D

DOUBLE SOLENOID

J
1/8” NPT
PILOT
Pilot Port
(expilot
valves Only)
VERSA

E
C/C* A C/C* D

A B B* C C* D E F G H J
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4”- 3/8” 3.50 88.9 1.15 29.2 1.84 47 1.62 41.3 2.54 64.6 2 51 1.0 25.4 1.56 39.6 0.75 19 2.98 75.7 3.83 97.4
1/2” 4.0 101.6 1.15 29.2 1.84 47 1.62 41.3 2.54 64.6 2.5 63.5 1.25 31.8 1.56 39.6 0.75 19 2.98 75.7 3.83 97.4
1” 8.63 219 2.01 51 — — 2.01 51 — — 3.75 95.3 1.88 47.8 2.5 63.5 1.19 30.2 5.14 130.5 4.3 109.2
*Dimensions for Spring-Centering Valves. For port and mounting hole locations for all valves shown above, refer to drawings top page 22.

www.versa-valves.com V-316 4-WAY 23


WAY-MOUNTING DIMENSIONS
PIILOT ACTUATED VALVES

SINGLE PILOT

PILOT
F PARAMUS
N.J. U.S.A.
G

E
C A B/B* D

DOUBLE PILOT

PARAMUS
PILOT
PILOT

NJ USA
F V E R S A

C/C* A E
C/C* D

A B B* C C* D E F G
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4” - 3/8” 3.5 88.9 1.15 29.2 1.78 45.1 1.25 31.8 2.17 55 2.19 55.6 1.19 30.2 1.56 39.6 0.75 19.1
1/2” 4.0 101.6 1.15 29.2 1.78 45.1 1.25 31.8 2.17 55 2.5 47.1 1.25 31.8 1.56 39.6 0.75 19.1
1” 8.63 219.1 2.01 0.51 — — 2.01 0.51 — — 1.88 47.8 2.5 63.5 1.19 30.2 1.19 30.2
*Dimensions for Spring-Centering Valves.

DIAPHRAGM ACTUATED VALVES

SINGLE DIAPHRAGM

D
F
PARAMUS
N.J. U.S.A.
G

E
C A B/B* D

DOUBLE DIAPHRAGM

E
C/C* A C/C* D

A B B* C C* D E F G
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4” - 3/8” 3.5 88.9 1.15 29.2 1.75 45.1 2.0 51 2.3 58.4 3.25 82.6 1.63 41.3 1.56 39.6 0.75 19.1
1/2” 4.0 101.6 1.15 29.2 1.75 45.1 2.0 51 2.3 58.4 3.25 82.6 1.63 41.3 1.56 39.6 0.75 19.1
*Dimensions for Spring-Centering Valves.
For port and mounting hole locations for all valves shown above, refer to drawings top page 22.

24 V-316 4-WAY www.versa-valves.com


WAY-MOUNTING DIMENSIONS
SOLENOID ACTUATED VALVES (Hazardous Service -XDB_)
DOUBLE SOLENOID K

1/8” NPT
Pilot Port
Manual Override (expilot
PILOT H
valves Only)

VERSA
F

E
B/B* A C D

SINGLE SOLENOID
K

1/8” NPT
Pilot Port
(expilot PILOT H
valves Only)

VERSA
E
C/C* A C/C* D

A B B* C C* D E F G H J KØ
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4”- 3/8” 3.50 88.9 1.15 29.2 1.84 47 2.31 58.7 2.94 74.7 2 51 1.0 25.4 1.56 39.6 .75 19.1 2.83 72 5.16 131.2 2.5 63.5
1/2” 4.0 101.6 1.15 29.2 1.84 47 2.31 58.7 2.94 74.7 2.5 63.5 1.25 31.8 1.56 39.6 .75 19.1 2.83 72 5.16 131.2 2.5 63.5
1” 8.63 219.1 2.01 51 — — 13.8 350.5 — — 3.75 95.3 1.88 47.8 2.5 63.5 1.19 30.2 4.9 124.3 6.5 165 2.5 63.5
*Dimensions for Spring-Centering Valves.

SOLENOID ACTUATED VALVES (Hazardous Service Valves -XMA_)


SINGLE SOLENOID K

M20 x 1.5
F CONDUIT
ENTRY H
G

E
B/B* A C/C* D

DOUBLE SOLENOID
K

M20 x 1.5
CONDUIT
ENTRY H

C/C* E
C/C* A D

A B B* C C* D E F G H J K
SIZE
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
1/4”- 3/8” 3.50 88.9 1.15 29.2 1.84 47 1.62 41.3 4.1 104.1 2 51 1 25 1.56 39.6 0.75 19.1 1.0 25.4 4.0 101 2.6 65
1/2” 4.0 101.6 1.15 29.2 1.84 47 1.62 41.3 4.1 104.1 2.5 63.5 1.25 31.8 1.56 39.6 0.75 19.1 1.0 25.4 4.0 101 2.6 65
1” 8.63 219.1 2.01 51 — — 4.36 110.7 — — 2.31 5.87 1.88 47.8 2.5 63.5 1.19 30.2 2.7 68.6 5.7 144.8 2.6 65
*Dimensions for Spring-Centering Valves. For port and mounting hole locations for all valves shown above, refer to drawings top page 22.

www.versa-valves.com V-316 4-WAY 25


Combination Actuators
Combination Actuators are a combination of two for control of intricate systems.
actuating devices into one unit that can be applied to
either end of a valve body assembly. This allows for a Cross section drawings and descriptions are
third actuating device to be applied to the opposite end presented here for understanding of actuator
of the valve body assembly. function. They are indicated in the product number
Use of Combination Actuators allows for control of by use of the prefix “A” and the appropriate suffix
various interlock circuits, and in many cases reduces that represents the specific Combination Actuator
the total number of valves and overall circuitry required involved.
Manual
* Hand Lever-Two Detent * Hand Lever-Three Detent * Hand Lever-Spring
Cap Assembly Cap Assembly Return (S) Cap Assembly
CA-4302-69L-316-113LE CA-4302-69L-316-114LE CA-4302-69L-316-130LAE
For ¼”Thru ½” Valves For ¼”Thru ½” Valves For ¼”Thru ½” Valves
This Cap Assembly is denoted in the This Cap Assembly is denoted in the This Cap Assembly is denoted in the
prefix letters of the valve product no. by prefix letters of the valve product no. by prefix letters of the valve product no. by
the letter “A” and suffix detail “-113LE.” the letter “A” and suffix detail “-114LE.”
the letter “A” and suffix detail “-130LAE.”

10º
10º
20º

20º

Hand Lever-Spring Center Button-Two Detent Button-Spring Return


(D — One Direction) Cap Assembly (R) Cap Assembly
Cap Assembly CA-4302-86-316-115E CA-4302-86-316-136E
CA-4302-69L-316-135LE For ¼” Thru ½” Valves For ¼” Thru ½” Valves
For ¼” Thru ½” Valves This Cap Assembly is denoted in the This Cap Assembly is denoted in the
This Cap Assembly is denoted in the prefix prefix letters of the valve product no. by prefix letters of the valve product no. by
letters of the valve product no. by the letter the letter “A” and suffix detail “-115E.” the letter “A” and suffix detail “-136E.”
“A” and suffix detail “-135LE”

10º 10º

Button-Spring Return Button-Reverse Spring Button-Spring Return


(S) Return with Manual Latch with Manual Latch
Cap Assembly CA-4302-86-316-136DRE CA-4302-86-316-181DRE
CA-4302-86-316-136PE For ¼” Thru ½” Valves For ¼” Thru ½” Valves
This Cap Assembly is denoted in the
For ¼” Thru ½” Valves This Cap Assembly is denoted in the prefix
letters of the valve product no. by the letter prefix letters of the valve product no. by
This Cap Assembly is denoted in the the letter “A” and suffix detail “-181DRE.”
prefix letters of the valve product no. by “A” and suffix detail “-136DRE.”
the letter “A” and suffix detail “-136PE.”

26 www.versa-valves.com
Combination Actuators - Special Purpose Actuators
Pilot
Pilot-Two Detent Cap Assembly Pilot, Push/Pull, Pilot, Pull
CA-4302-64-316-150E Spring Center CA-4302-64-316-PTP
For ¼”Thru ½”Valves CA-4302-83-316-4003PE For ¼”Thru ½”Valves
This Cap Assembly is denoted in the
prefix letters of the valve product no. by For ¼”Thru ½”Valves This Cap Assembly is denoted in the
This Cap Assembly is denoted in the prefix letters of the valve product no.
the letter “A” and suffix detail “-150E.”
prefix letters of the valve product no. by by the letter “A” and suffix detail “-PTP.”
the letter “A” and suffix detail “-4003PE.”

Pilot Pull Type Pilot-Spring Return (S) Diaphragm-Spring Return (S)


“AIR LATCH” hold function only Cap Assembly Cap Assembly
CA-4302-64-316-301RE CA-4302-64-316-159E CA-4302-87-316-160E
For ¼”Thru ½” Valves For ¼”Thru ½” Valves For ¼”Thru ½” Valves
This Cap Assembly is denoted in the prefix This Cap Assembly is denoted in the prefix This Cap Assembly is denoted in the prefix
letters of the valve product no. by the letter letters of the valve product no. by the letter letters of the valve product no. by the letter
“A” and suffix detail “-301RE” “A” and suffix detail “-159E.” “A” and suffix detail “-160E.”

Solenoid/Pilot
Solenoid/Pilot-2 Detent Cap Solenoid/Pilot- Reverse Spring Solenoid/Pilot- Dual Piston
Assembly Return (R) Cap Assembly Assembly
CA-4302-84-316-173E (EXPilot) CA-4302-84-316-138E (EXPilot) CA-4302-84-316-DP (EXPilot)
CA-4322-84-316-173E (INPilot) CA-4322-84-316-138E (INPilot) CA-4322-84-316-DP (INPilot)
For ¼”Thru ½”Valves For ¼”Thru ½”Valves For ¼”Thru ½”Valves
This Cap Assembly is denoted in the prefix This Cap Assembly is denoted in the prefix This Cap Assembly is denoted in the prefix
letters of the valve product no. by the letter “A” letters of the valve product no. by the letter “A” letters of the valve product no. by the letter
and suffix detail “-173E.” and suffix detail “-138E.” “A” and suffix detail “-DP.”

www.versa-valves.com 27
VERSA SPECIAL PURPOSE DUAL SOLENOID VALVES

Push Pull Solenoid Suffix -PPG


General Description
A dual solenoid valve with a hand lever. The design concept is to provide the
functionality of a dual coil, 2-position valve with the addition of manual control
or any other actuator. The valve operates as standard 2-position requiring
only momentary electrical contact to shift valve. Various manual actuators
are available. The lever shown is an “L” type which can be manually set in
either offset position when the solenoid valve is de-energized.

Redundant Solenoid 2oo2, Suffix -RS


General Description
When parallel electronic control circuits are utilized in a system, if a complete
control circuit fails or requires maintenance, the parallel circuit will keep the system
running. In a parallel circuit Versa’s Redundant Valve functions the
same as a solenoid operated-spring return valve, except that it has
two solenoids (one for each of the parallel circuits) rather than one
solenoid. Either or both of these solenoids will shift and maintain
the controlled device in the shifted position. Both solenoids must
be de-energized to return the controlled device to the un-shifted position.
The use of one Redundant Valve can replace multiple valves and components to
accomplish the same function. This function can be considered as a (2oo2).

Shut Off Valve 1oo2, Suffix -SOV


General Description
While the Shut off Valve looks similar to the Redundant Solenoid Valve (shown
above) the internal pilot circuit is different. The -SOV option provides a series
pilot control circuit that requires both coils, a primary and a secondary,
to be energized in order for the valve to shift. Conversely if the
electrical signal to either coil is removed the valve will return to
the de-energized position. This function can be considered as a
(1oo2), where various control devices (e.g., temperature, pressure
switches) could be wired in series with each coil. The actuation of
any one of these devices, attached to either coil, would interrupt the signal
to the coil and cause the valve to shift to the de-energized position.
B
A

B
A
B
A

EA

EB
EA

EB

EA

EB

IN
IN

IN

-PPG Flow Schematic -RS Flow Schematic -SOV Flow Schematic

28 www.versa-valves.com
VERSA SPECIAL PURPOSE DUAL SOLENOID VALVES

How to specify SPECIAL PURPOSE DUAL SOLENOID VALVES


V SA - 3 5* 2 1 - 316 - RS (OPTIONS)
V = V Series

LA = -PPG with Lever


IA = -PPG with Button
AA = -PPG with Latch, see page 28
SA = -RS -SOV with Spring Return
AA = -RS -SOV with Latch, see page 28

3 = Three-way
4 = Four-way

3 = 1/4”NPT
4 = 3/8”NPT
5 = 1/2”NPT

2 = Threaded sideports-INPilot solenoid: no auxiliary pilot required.

1 = 3-way NC
2 = 3-way NO, 4-way/2-position
3 = 4-way/3-Position (blocked center)
4 = 4-way/3-Position (exhaust ports open in center)

316 = Stainless steel valve identifier.

-RS
SPECIAL PURPOSE DUAL SOLENOID VALVES SUFFIX -SOV
-PPG

OPTIONS (Refer to pages 8 to 9 for specific certifications, standards & classifications, approvals,
protective codes and voltage codes.)
*Not available in 1”.
Installation, Filtration And Lubrication Valves have no limitations on mounting orientation. 40 to 50 micron filtration and general purpose lubricating oil
ISO, ASTM viscosity grade 32 recommended.

Dimensions A

A
B4 A2

E
Netherlands
N.J., USA &

EB IN EA
5 3 1

VERSA
N. J., U.S.A.

D
C
B

B4 A2
VERSA®
Netherlands
N.J., USA &

D EB IN
3
EA
1
C

SIZE A B† C† D SIZE A B† C† D E
R 3 in 7.04 3.52 2.0 1 3 1/4 & 3/8 5.8 3.21 4.2 4.2 6.32
1/4 & 3/8
W mm 179 89 51 25.4 W 147.3 81 106.6 106.7 160
S
A in 7.69 3.52 2.5 1.25 A 6.26 3.21 4.2 4.2 6.32
1/2 P 1/2
or Y mm 195 89 63.5 31.8 Y 159 81 106.6 106.7 160
P
4 in 8.35 3.52 2.0 1 4 7.28 3.21 4.2 4.2 6.32
S 1/4 & 3/8 G 1/4 & 3/8
W mm 212 89 51 25.4 W 185 81 106.6 106.7 160
O A A
in 8.85 3.52 2.5 1.25 7.78 3.21 4.2 4.2 6.32
V 1/2 1/2
Y mm 224.8 89 63.5 31.8 Y 198 81 106.6 106.7 160

Dimensions listed are for -XX type hazardous service solenoids. For dimensions with other hazardous service solenoids that can be applied, consult factory. Dimensions
for standard non-hazardous service solenoids will be slightly less than those listed.

www.versa-valves.com 29
VERSA LATCHING/MANUAL RESET VALVES
Latching/Manual Reset Three-Way Valve, Solenoid Actuated.
Latching valves are particularly suited to applications where (VAG-3521-316-181D-XDBT1-D024 shown)
it is desirable or mandatory to manually reset or restart a
system. A typical application could involve the emergency
shutdown of automatically monitored process operations.
Loss or interruption of the control signal to the valve actuator
causes the valve to shift, latch and shut-down a process
step. When the signal is restored the valve remains in the
latched position until the operator manually unlatches it
and allows the process step to resume. Positive latching in
such an application is vitally important since many process
operations are sequential and one step must not be started
until the one ahead of it has started.
This example is only one of many which can be
accommodated through the use of Versa’s Latching Valves.
A wide range of functional types, port sizes, actuators, and
latching arrangements provides the engineer with a complete
choice of valves to meet the requirement of the application.
The Latching Device actuator consists of an integral spring for returning the valve plunger,
and an inline hand operator where needed to manually shift the valve. The specific Latching
Device may be attached to any Series V-316 valve body size or style. Typically the actuator on the
opposite end of the valve body would be an automatic type such as a solenoid, a remote pressure pilot, or a
low pressure diaphragm actuator.

LATCHES IN ACTUATED POSITION LATCHES IN UNACTUATED POSITION

Suffix Detail-181BE Latches automatically when Suffix Detail -181D Unlatching allows valve spool
plunger shifts on signal. to be shifted manually or on
Unlatching allows plunger to signal. Spring returns valve
be returned by hand. spool automatically when
signal is removed, and valve
latches. (If hand lever is not
required, see suffix -3358
below.)

Suffix Detail -3358E Unlatching allows plunger to


shift on signal. Spring returns
plunger automatically and
valve latches. (If hand lever is
required for manual actuation
see suffix -181D above.)
Suffix Detail -181CE Latches automatically when
valve spool has been shifted on
signal or manually against the
spring. Unlatching allows the
spring to return the valve spool
automatically. (If hand lever is
not required, see suffix -3358A
bottom right.)
Suffix Detail-3358AE Latches automatically
when valve spool shifts on
signal. Unlatching allows
the spring to return valve
spool automatically. (If hand
lever is required for manual
actuation see suffix -181C
above.)

30 www.versa-valves.com
How to specify
LATCHING/RESET VALVES SERIES V-316 VALVES

V AG - 3 5 2 1 - 316 - 181B - (OPTIONS)

V = Pneumatic service: vacuum to 200 psi (14 bar)

AG = Solenoid/pilot operated (NEMA 1,2,3)


(2NC, 3NC, 4-way, 5-way, Selector, Diverter)
AP = Remote pressure pilot operated
(2NC, 3NC, 4-way, 5-way, Selector, Diverter)
AW= Diaphragm (low pressure) pilot operated
(2NC, 3NC, 4-way, 5-way, Selector, Diverter)
GA = Solenoid/pilot operated (NEMA 1,2,3)
(2NO, 3NO, Selector, Diverter)
PA = Remote pressure pilot operated
(2NO, 3NO, Selector, Diverter)
WA = Diaphragm (low pressure) pilot operated
2NO, 3NO, Selector, Diverter)

2= Two-way
3= Three-way
4= Four-way
5= Five-way
7= Diverter (one inlet-two outlets)
8= Selector (two inlets-one outlet)

3= 1/4” NPT
4= 3/8” NPT
5= 1/2” NPT
7= 1” NPT* * 1” Valve Latch available, consult factory for part number

0 = Threaded side ports - For all type actuators:


For controlling vacuum to 200 psi (14 bar) air and where controlled medium or
source is different than pilot medium or source. Solenoid/pilot or remote
pressure pilot requires aux pilot pressure 40-175 psi (2.8-12 bar) air.
Diaphragm pilot requires aux pilot pressure 5-50 psi (0.34-3.4 bar) air.
2 = Threaded side ports - INPilot solenoid only:
For controlling pressures 40-175 psi (2.8-12 bar) air. No auxiliary pilot required.

1= 2NC, 3NC
2= 2NO, 3NO, 4-way two position, 5-way two position, Selector, Diverter
3= Three-position, 3, 4, 5-way, Selector, Diverter,-all ports closed in center position.
4= Three-position, 3, 4-way, — exhaust ports open in center position.

316 = Stainless steel valve identifier.

-181BE
-181CE Locking/reset device
-181D (refer to page 30 for
-3358 specific device required)
-3358A

OPTIONS
-XX = Solenoid operator for hazardous service (NEMA 7 & 9);
Class I, Division 2 (A & B); Class I, Division 1 (C & D);
Class II, Division 1 (E, F & G).
-LB = Low watt (1.8W) solenoid operator for hazardous service (NEMA 7 & 9)
Max operating pressure 120 PSI (8.3 bar)

Consult factory for specific certifications, standards & classifications, approvals, and protective codes.

www.versa-valves.com 31
VERSA SOLENOID CONTROL SYSTEM TEST VALVE

ByPass Valve
General Description
Versa’s ByPass valve provides an option for testing
solenoid valve control circuits in applications where
closing down or “shutting in” the system is not an option.
The ByPass valve allows the testing and replacement of
a component within the circuit without shutting down the
main system. Versa’s solution is simple to apply, operate
and is accomplished in one valve. The basic valve is a
3-position manual valve. Operation is as follows:
Position 1. This position is the normal position or Position 3. This position places the control
the regular operation mode. system in a replace mode. Should it be
determined that a component in the control
Position 2. This position places the control circuit
circuit needs to be repaired and or replaced
in the test mode. In this position the ByPass valve
this position allows total isolation from
allows pressure to the circuit for testing while
pressure while still holding system pressure to
maintaining pressure on the actuator. With
actuator.
pressure to solenoid inlet and solenoid circuit
outlet blocked/isolated this position allows Based on Versa proven V-316 series high flow valve.
complete testing of solenoid circuit without shutting Actuation is available as a rotary switch or key
down the system. operated. Optional position indication available.

Solenoid
Valve

Bypass Valve

Positions 3 2 1
5 3

B4 A2
To Actuator Supply

Dimension Drawing Position Indicator


In Position 3

B In Position 2

VAU-450X-316-314E***-9E-2039 In Position 1
is shown with key actuation
and optional position indicator.
C

D A

Port A B C D Position 1 Position 2 Position 3


SIZE* in mm in mm in mm in mm in mm in mm in mm
1/2 6.52 166 3.61 92 1.56 39.7 2.5 63.5 0.45 11.5 0.63 16 0.80 20.5
*For ¼” port size see C-316 Series Bulletin. Not available in 1”.
For port and mounting hole locations refer to drawings top page 22

32 www.versa-valves.com For port and mounting hole locations refer to drawings top page 22.
VERSA LOCKOUT VALVES

Palm Button Actuated, 3-Way or 4-Way, 1/4”, 3/8”, and 1/2”, NPT
The LOVEE 3-Way is a NC valve in the locked position. Blocking the inlet and bleeding all
air in the system to atmosphere. The LOVBE can be locked in either open or closed position.

EXAMPLES

VZI-4301-316-LOVBE VZI-3301-316-LOVEE
Shown with standard black knob Shown with optional red knob
Suffix -125R Red
Suffix -125G Green

VIZ-3301-316-LOV*
D
G Ø PADLOCK E
OUT
3
VERSA®
Netherlands
N.J., USA &

IN EX
2 3
F
A/A*
H TRAVEL J MAX

VERSA C
PARAMUS
NJ USA

K Button Ø L PANEL HOLE Ø B

FLOW SYMBOL LOVBE FLOW SYMBOL LOVEE


A2

3 1
IN EA
LOCKING IN PRESSURIZED POSITION
LOCKING IN EXHAUSTING POSITION
LOCKING IN EXHAUSTING POSITION

PORT A A* B C D E F GØ H J KØ LØ
SIZE* in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm

3 1/4”- 3/8” 6.3 101.6 0.34 86 2.0 51 1.5 38.1 1.09 29.2 0.66 16.7 0.62 15.8 0.26 6.5 0.34 8.6 0.5 12.7 1.81 46 1.0 25.4
WAY 1/2” 6.9 175 0.34 86 2.5 63.5 1.56 39.6 1.42 36 0.66 16.7 1.32 33.5 0.26 6.5 0.34 8.6 0.5 12.7 1.81 46 1.0 25.4

4 1/4”- 3/8” 7.28 193.5 0.34 86 2.0 51 1.5 38.1 1.75 44.5 0.66 16.7 1.26 32.5 0.26 6.5 0.34 8.6 0.5 12.7 1.81 46 1.0 25.4
WAY 1/2” 8.12 206 0.34 86 2.5 63.5 1.56 39.6 2.0 51 0.66 16.7 1.31 33.3 0.26 6.5 0.34 8.6 0.5 12.7 1.81 46 1.0 25.4
*Not available in 1”

www.versa-valves.com 33
Modular Air Package
Based on the V-316 Series
General Description
The Versa Modular Air Package is a compact air management system, based on V-316 Series components, that will provide a full
range of pneumatic accessories and functions to meet the needs of most control systems in the actuator control industry. Major
components are shutoff and check valves, filter/regulators, speed controls and directional control valves.

Design Benefits
Versa’s VMAP simplifies the design process by combining all the components of a common circuit into one integrated assembly.
Whether a standard shutoff circuit or an intricate control system, VMAP has the features to meet the requirements of any control
project. VMAP will reduce engineering, components, vendors, costs, weight and save time.

TROUBLE FREE. Designed with integral assembly flanges EFFICIENCY. VMAP’s modular design effectively groups common
combined with all O ring interface sealing and standard automation and controls components together in user approved
fasteners. Long leak free service life is accomplished. No groupings to combine features and reduce size and weight.
custom or flat gaskets to leak or brackets to fail.

TECHNOLOGY. Utilizing PROVEN. VMAP is based on Versa’s field


the latest in computer aided proven V-316 Series product. Having over
design and finite element 30 years of acceptance in providing bubble
software flow is maximized tight sealing though Versa’s packed plunger
yielding the highest flow in the technology.
smallest of packages.

CUSTOM CIRCUITRY is FLEXIBILITY. Many


achieved through modular standard and custom
design by simply combining circuits are easily created
various components to create using the VMAP modular
the desired circuit concept.

RELIABILITY. The reliability of the Versa INNOVATIVE. Through the use of


V-316 Series combined with industry investment casting technology main
approved materials yields a proven components are integrated saving space
product. SIL (Safety Integrity Levels) while reducing potential leakage points.
exceeding most application requirements.
ENGINEERING BENEFITS
• Standard or custom circuits available utilizing VMAP’s modular components.
• Convenience of one purchase order and one vendor.
• No need for developing Bill of Materials for fittings, tubing and bracketing.
• No need for designing a complete layout of many different system components.
• No need for designing brackets for many individual components.

FIELD BENEFITS INSTALLATION BENEFITS


• Ease of repair: By removing a few screws the various
• Reducing fittings, tubing and related labor costs
modules can be disassembled and inspected, no tubing or
fittings to remove. • Reduction in size and weight
• Field configurability of function after installation: Add • One component to mount
more valves as the requirements of the process change.
• 10 year warranty Current Technology
NEW

See VMAP Bulletin VMAP and Panel shown at scale


online at Versa Website

34 www.versa-valves.com
MISCELLANEOUS INFORMATION
Hazardous Location Combination Suffix Details
Cross Reference Chart
Suffix Reference North American (-XX) (Cont.) ATEX (XN) (Cont.)
Suffix Description Combination
Included Suffix
Combination
Included Suffix
-XX North American solenoid Suffix Suffix
-XN ATEX solenoid -XXH4 -XX, -D14, -HT, -PC, -ST -XNL -XN, -PC
-XDB World Solenoid -XXJ -XX, -LB, -PC, -ST -XNM -XN, -HT, -PC
-HT Class H coil -XXJ4 -XX, -D14, -LB, -PC, -ST -XNN -XN, -LB, -PC
-ST Stainless solenoid housing -XXK -XX, -HT, -LB, -PC, -ST -XNP -XN, -HT, -LB, -PC
-PC Potted coil -XXK4 -XX, -D14, -HT, -LB, -PC, -ST -XNQ -XN, -HT, -LB
-LB 1.8 watt solenoid -XXL -XX, -PC -XNR -XN, -LB
-LA 0.85 watt solenoid -XXL4 -XX, -D14, -PC -XNS -XN, -LA, -ST
-VJBT Add on Junction Box -XXM -XX, -HT, -PC -XNU -XN, -HT, -LB, -ST
-D14 Solenoid vent, water proof nut -XXM4 -XX, -D14, -HT, -PC -XNV -XN, -LA
-PS Potted coil, male conduit -XXN -XX, -LB, -PC -XNX -XN, -LB, -PS
-CD 72” wire leads -XXN4 -XX, -D14, -LB, -PC -XNWS -XN, -VJBT, -LB, -PS
-LX 1.8 watt solenoid -XXP -XX, -HT, -LB, -PC -XXK4 -XX, -D14, -HT, -LB, -PC, -ST

-H2E 1/8” npt solenoid vent -XXP4 -XX, -D14, -HT, -LB, -PC
-HE ¼” npt solenoid vent -XXQ -XX, -HT, -LB
-L14 solenoid vent dust nut -XXQ4 -XX, -D14, -HT, -LB World Solenoid (XDB)
-XXR -XX, -LB Combination
-303D Integral diode Included Suffix
-XXR4 -XX, -D14, -LB Suffix
-XXS -XX, -LA, -ST -XDBS1 -XDBS, -HT, -LX
-XXS4 -XX, -D14, -LA, -ST -XDBS2 -XDBS, -HT, -LX, -H2E
North American (-XX) -XXU -XX, -HT, -LB, -ST -XDBS3 -XDBS, -HT, -LX, -HE
Combination -XXU4 -XX, -D14, -HT, -LB, -ST -XDBS4 -XDBS, -HT, -LX, -L14
Included Suffix
Suffix -XXV -XX, -LA -XDBS5 -XDBS, -HT, -LX, -303D
-XXA -XX, -HT -XXV4 -XX, -D14, -LA -XDBS6 -XDBS, -HT, -LX, -H2E, -303D
-XXA4 -XX, -D14, -HT -XXW -XX, -CD, -HT, -H2, -PC, -ST -XDBS7 -XDBS, -HT, -LX, -HE, -303D
-XXB -XX, -PS -XXW4 -XX, -D14, -CD, -HT, -PC, -ST -XDBS8 -XDBS, -HT, -LX, -L14, -303D
-XXB4 -XX, -D14, -PS -XDBS9 -XDBS, -HT, -LX, -D14
-XXC -XX, -HT, -PS ATEX (XN) -XDBS10 -XDBS,-HT,-LX,-D14, -303D
-XXC4 -XX, -D14, -HT, -PS Combination -XDBT1 -XDBT, -HT, -LX
Included Suffix
-XXD -XX, -ST Suffix -XDBT2 -XDBT, -HT, -LX, -H2E
-XXD4 -XX, -D14, -ST -XNA -XN, -HT -XDBT3 -XDBT, -HT, -LX, -HE
-XXE -XX, -PC, -ST -XND -XN, -ST -XDBT4 -XDBT, -HT, -LX, -L14
-XXE4 -XX, -D14, -PC, -ST -XNE -XN, -PC, -ST -XDBT5 -XDBT, -HT, -LX, -303D
-XXF -XX, -HT, -ST -XNF -XN, -HT, -ST -XDBT6 -XDBT, -HT, -LX, -H2E, -303D
-XXF4 -XX, -D14, -HT, -ST -XNG -XN, -LB, -ST -XDBT7 -XDBT, -HT, -LX, -HE, -303D
-XXG -XX, -LB, -ST -XNH -XN-HT, -PC, -ST -XDBT8 -XDBT, -HT, -LX, -L14, -303D
-XXG4 -XX, -D14, -LB, -ST -XNJ -XN, -LB, -PC, -ST -XDBT9 -XDBT, -HT, -LX, -D14
-XXH -XX, -HT, -PC, -ST -XNK -XN, -HT, -LB, -PC, -ST -XDBT10 -XDBT, -HT, -LX, -D14, -303D

Recommended Hazardous Location Solenoid Option Packages


(For complete specifications please see above and page 8)
Certification/Power

North American - CSA ATEX - IECEx - INMETRO


Enclosure/Wire Standard Power Low Watt* Standard Power Low Watt*
Steel, Electroless Nickel Plated, 24 Inch Leads -XXL4 -XXN4 -XNL4 -XNN4
Stainless Steel, High Performance 430 type, 24 Inch leads -XXE4 -XXJ4 -XNE4 -XNJ4
Stainless Steel, 316L type, Junction Box with Terminal Strip — -XDBT9** — -XDBS9
* 1.8 watt solenoid. Also available is 0.85 watt, see cross reference chart above. For 0.50 watt, consult factory.
** All the –XDBT type solenoids are “World Solenoids.” Certified for North America, ATEX, IECEx and INMETRO

www.versa-valves.com 35
Versa has been
supplying the
fluid power
industry with
pneumatic and
hydraulic
components
for over 50
years. We
have built a
reputation for
quality that is
unsurpassed
in the market
for high
performance
solenoids,
pneumatic
relays,
resets and
pilot valves.

WARNINGS REGARDING THE DESIGN APPLICATION,


INSTALLATION AND SERVICE OF VERSA PRODUCTS

The warnings below must be read and reviewed before designing a system utilizing,
installing, servicing, or removing a Versa product. Improper use, installation or servicing of LIMITED WARRANTY DISCLAIMER
a Versa product could create a hazard to personnel and property. AND LIMITATION OF REMEDIES
DESIGN APPLICATION WARNINGS Versa’s Series products are warranted
Versa products are intended for use where compressed air or industrial hydraulic fluids are to be free from defective material and
present. For use with media other than specified or for non-industrial applications or other workmanship for a period of ten years
applications not within published specifications, consult Versa. from the date of manufacture, provided
Versa products are not inherently dangerous. They are only a component of a larger said products are used in accordance
system. The system in which a Versa product is used must include adequate safeguards to with Versa specifications. Versa’s
prevent injury or damage in the event of system or product failure, whether this failure be of liability pursuant to that warranty
switches, regulators, cylinders, valves or any other system component. System designers is limited to the replacement of the
must provide adequate warnings for each system in which a Versa product is utilized.
These warnings, including those set forth herein, should be provided by the designer to Versa product proved to be defective
those who will come in contact with the system. provided the allegedly defective
product is returned to Versa or its
Where questions exist regarding the applicability of a Versa product to a given use, inquiries authorized distributor. Versa provides
should be addressed directly to the manufacturer. Confirmation should be obtained directly
from the manufacturer regarding any questioned application prior to proceeding. no other warranties, expressed or
implied, except as stated above.
INSTALLATION, OPERATION AND SERVICE WARNINGS There are no implied warranties
Do not install or service any Versa product on a system or machine without first of merchantability or fitness for a
depressurizing the system and turning off any air, fluid, or electricity to the system or
machine. All applicable electrical, mechanical, and safety codes, as well as applicable particular purpose. Versa’s liability for
governmental regulations and laws must be complied with when installing or servicing a breach of warranty as herein stated is
Versa product. the only and exclusive remedy and in
no event shall Versa be responsible or
Versa products should only be installed or serviced by qualified, knowledgeable personnel
who understand how these specific products are to be installed and operated. The liable for incidental or consequential
individual must be familiar with the particular specifications, including specifications for damages.
temperature, pressure, lubrication, environment and filtration for the Versa product which
is being installed or serviced. Specifications may be obtained upon request directly from
Versa. If damages should occur to a Versa product, do not Operate the system containing
the Versa product. Consult Versa for technical information.

Versa Products Company, Inc. Versa BV


22 Spring Valley Road Prins Willem Alexanderlaan 1427 ®
Paramus, New Jersey 07652 7321 GB Apeldoorn
USA The Netherlands
Phone: (201) 843-2400 Phone: +31-55-368-1900
Fax: (201) 843-2931 Fax: +31-55-368-1909 www.versa-valves.com
email: sales@versa-valves.com