Resistance temperature sensors instructions provide guidance for completing forms related to resistance temperature sensors. Key details include:
1) The complete sensor assembly includes the head, element, and well as shown in an illustration.
2) Additional details like the size and type of process connection, sealing of sensor leads, number of sensor wires, and internal threading should be specified.
3) Notes should be provided at the bottom of the form to explain any special requirements or additional sensor specifications.
Resistance temperature sensors instructions provide guidance for completing forms related to resistance temperature sensors. Key details include:
1) The complete sensor assembly includes the head, element, and well as shown in an illustration.
2) Additional details like the size and type of process connection, sealing of sensor leads, number of sensor wires, and internal threading should be specified.
3) Notes should be provided at the bottom of the form to explain any special requirements or additional sensor specifications.
Resistance temperature sensors instructions provide guidance for completing forms related to resistance temperature sensors. Key details include:
1) The complete sensor assembly includes the head, element, and well as shown in an illustration.
2) Additional details like the size and type of process connection, sealing of sensor leads, number of sensor wires, and internal threading should be specified.
3) Notes should be provided at the bottom of the form to explain any special requirements or additional sensor specifications.
Refer to Scientific Apparatus Manufacturers Association (SAMA) Tentative Standard on Resistance, RC 5-10-1955. 1) Complete assembler includes head, element, and well; as shown in sketch. 5) Give size and pipe schedule of nipple. Check if union is required. 7) The ice point resistance in ohms usually defines the resistance vs. temperature curve. If not, provide additional data as an attachment. 8) Give maximum range over which the elements will be used. 9) Specify sealing of leads. 11) This thread is on the element termination, not the well. 12) It is necessary to specify the number of wires, depending on the compensation required. The other items refer to the element termination. 14) A built-up well has a welded tip and connection. 16) Internal thread of flange if well flange is threaded. Instructions for the tabulation: 17) Process Connection is the connection on the element or well which is connected to the pipe or vessel. Well dimensions are illustrated in the sketch. It is not necessary to specify "Element Length" if well dimensions are already given. Single or Dual elements are assumed to be within the same sheath. Refer to Notes by number or letter and explain in the space at the bottom of the form.