Intake Air Heater #1 Circuit - Voltage Below Normal or Shorted to Low Source
Fault Code: 2556 Intake Air Heater #1 Circuit - The intake air heaters may be ON or OFF all the
PID(P), SID(S): S070 Voltage Below Normal or Shorted time.
SPN: 729 to Low Source. Low voltage
FMI: 4 detected at the intake air heater
Lamp: Amber signal circuit.
SRT:
Circuit Description:
The intake air heater improves starting and white smoke control in cold ambient conditions. The ECM controls relays
that switch power to the intake air heater. 12-volt systems will have two relays while 24-volt systems only require one
relay.
Component Location:
The intake air heater is located at the air inlet connection into the intake manifold. The location of the intake air heater
relays will vary by OEM. Refer to Section E for a detailed component location view.
Shop Talk:
Possible causes of this fault code include:
• A shorted intake air heater relay
• Intake air heater relay supply wire shorted to ground.