Circuit Description:
The VGT is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information
via the J1939 data link from the primary engine engine control module (ECM). The VGT actuator performs its own
diagnostics and reports failures back to the primary engine ECM using the J1939 data link.
Component Location:
The VGT actuator is located on the turbocharger bearing housing.
© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 27-Aug-2013
File: 06-fc9122 Page 2 of 3
Action Taken When the Fault Code is Active:
The ECM illuminates the amber CHECK ENGINE light immediately when the diagnostic runs and fails.
Shop Talk:
Verify the ECM calibration is correct. Check the calibration revision history found on QuickServe® Online for
applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. Refer to Procedure 019-032
in Section 19 in the corresponding Troubleshooting and Repair Manual for the engine being serviced.
This fault code will log when the internal temperature of the VGT actuator exceeds 125°C [257°F].
This fault code will be inactive when the vehicle is in the shop because the VGT actuator temperature has cooled
down.
Troubleshoot multiple inactive counts of this fault code as an active fault code.
Also check for exhaust leaks blowing on the VGT actuator. Repair any external leaks.
© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 27-Aug-2013
File: 06-fc9122 Page 3 of 3