You are on page 1of 4

EQUIPMENT NAME:

PCI MAIN FAN

TIME/DATE 3/5/2023 5/5/2023 6/5/2023 (After replace pin TIME 3/5/2023 1200hrs
1130hrs 1200hrs rubber bush coupling)

VIBRATION (mm/s) VIBRATION (mm/s)

DE 1.00 1.00 0.80 DE 2.10 2.00

NDE 0.90 0.80 NDE 2.60 2.30

MOTOR VIBRATION GEARBOX/BEARING


(AXIAL) BLOCK/PUMP
(AXIAL)
BEARING (acceleration) BEARING (acceleration)

DE(gE) 6.35 6.92 0.90 DE(gE) 0.83 0.79

NDE(gE) 2.40 2.44 NDE(gE) 0.94 0.96

VIBRATION (mm/s) VIBRATION (mm/s)

DE 1.00 1.00 1.90 DE 1.00 1.30

NDE 0.90 0.90 NDE 1.90 1.90

MOTOR VIBRATION GEARBOX/BEARING


(HORIZONTAL) BLOCK/PUMP
(HORIZONTAL)
BEARING (acceleration) BEARING (acceleration)

DE(gE) 14.09 21.88 1.45 DE(gE) 1.75 2.11

NDE(gE) 3.65 2.91 NDE(gE) 1.13 1.08

VIBRATION (mm/s) VIBRATION (mm/s)

DE 0.70 0.8 1.60 DE 1.50 1.80

NDE 0.00 0.1 NDE 3.50 3.00


GEARBOX/BEARING
MOTOR VIBRATION BLOCK/PUMP
(VERTICAL) (VERTICAL)
BEARING (acceleration) BEARING (acceleration)

DE(gE) 16.44 27.33 0.88 DE(gE) 1.51 1.63

NDE(gE) 3.99 3.51 NDE(gE) 1.24 1.26

R(A) BEARING BLOCK

RUNNING AMP WITHOUT Y(A) TEMPERATURE WITHOUT LOAD DE (°C)


LOAD

B(A) NDE (°C)

R(A) BEARING BLOCK

RUNNING AMP WITH LOAD Y(A) TEMPERATURE WITH LOAD DE (°C) 50.70 47.40

B(A) NDE (°C) 52.30 49.8

BODY (°C)

TEMPERATURE WITHOUT DE (°C)


LOAD

NDE (°C)

BODY (°C)

TEMPERATURE WITH LOAD DE (°C) 47.50 48.50

NDE (°C) 40.30 44.30


Vibration monitoring on 3/5/2023 shown high vibration for acceleration enveloping(gE) at DE motor. However, reading f

On 6/5/2023 team decide to troubleshoot by replaced pin bush coupling. Notified scratch mark at old pin bush coupling.
otor. However, reading for velocity (mm/s) not indicate any high vibration.

at old pin bush coupling. After replacement, vibration reading shown in normal range.